JAFP-23-0048, Supplemental Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis

From kanterella
(Redirected from ML23243A946)
Jump to navigation Jump to search
Supplemental Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis
ML23243A946
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 08/31/2023
From: David Gudger
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
JAFP-23-0048 JAF-CALC-RAD-04410, Rev 4
Download: ML23243A946 (1)


Text

200 Exelon Way Kennett Square, PA 19348 www.exeloncorp.com 10 CFR 50.90 JAFP-23-0048 August 31, 2023 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 James A. FitzPatrick Nuclear Power Plant Renewed Facility Operating License No. DPR-59 NRC Docket No. 50-333

Subject:

Supplemental Information for License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis

Reference:

Letter from D. Gudger (Constellation Energy Generation, LLC) to U.S. Nuclear Regulatory Commission, License Amendment Request to Update the Technical Specification Bases to Change the Fuel Handling Accident Analysis, dated August 3, 2024.

By letter dated August 3, 2023 (Reference), Constellation Energy Generation, LLC (CEG) requested a change to the Technical Specification (TS) Bases to change the Fuel Handling Accident Analysis (FHA) due to new Refuel Bridge Mast NF-400 to NF-500 and definition for Recently Irradiated Fuel at James A. FitzPatrick Nuclear Power Plant (JAF). The impact of the proposed amendment would increase the consequences of the FHA analysis as well as reduce future refueling outage burden.

As discussed with the NRC Staff on August 29, 2023, attached is the analysis, "Fuel Handling Accident - AST Analysis for Relaxation of Secondary Containment Operability."

The purpose of this analysis is to determine the Exclusion Area Boundary (EAB), Low Population Zone (LPZ), and Control Room (CR) doses resulting from a Fuel Handling Accident (FHA) occurring in the Reactor Building (RB). The FHA analysis is performed using the Alternative Source Term (AST) methodology with guidance from Regulatory Guide 1.183.

CEG has reviewed the information supporting a finding of no significant hazards consideration and the environmental consideration provided to the NRC in the referenced document. The supplemental information provided in this letter does not affect the bases for concluding that the proposed license amendment does not involve a significant hazards

U.S. Nuclear Regulatory Commission Supplemental Information Fuel Handling Accident Docket No. 50-333 August 31, 2023 Page 2 consideration. Furthermore, the supplemental information provided in this letter does not affect the bases for concluding that neither an environmental impact statement nor an environmental assessment needs to be prepared in connection with the proposed amendment.

This letter contains no new regulatory commitments.

In accordance with 10 CFR 50.91, "Notice for public comment; State consultation,"

paragraph (b), CEG is transmitting a copy of this application and its attachments to the designated State Officials.

Should you have any questions concerning this submittal, please contact Abul.Hasanat@Constellation.com.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 31st day of August 2023.

Respectfully, Dave T. Gudger Senior Manager - Licensing & Regulatory Affairs Constellation Energy Generation, LLC

Enclosure:

1. Constellation Calculation JAF-CALC-RAD-04410, Fuel Handling Accident - AST Analysis for Relaxation of Secondary Containment Operability, Revision 4 cc:

USNRC Region I, Regional Administrator w/attachments USNRC Senior Resident Inspector, JAF w/attachments USNRC Project Manager, JAF w/attachments A. L. Peterson, NYSERDA w/attachments

ENCLOSURE 1 License Amendment Request James A. FitzPatrick Nuclear Power Plant Docket No. 50-333 Constellation Calculation JAF-CALC-RAD-04410, Fuel Handling Accident - AST Analysis for Relaxation of Secondary Containment Operability, Revision 4

CC-AA-309-1001-F-01 Revision 0 Constellation Confidential/Proprietary Design Analysis (Major Revision)

Last Page No. 6 182 Analysis No.:1 JAF-CALC-RAD-04410 Revision: 2 4 Major Minor

Title:

3 Fuel Handling Accident - AST Analysis for Relaxation of Secondary Containment Operability EC No.: 4 638505 Revision: 5 0

Station(s): 7 JAF Component(s): 14 Unit No.: 8 1

N/A Discipline: 9 NUDC Descrip. Code/Keyword: 10 A1/D5 Safety/QA Class: 11 SR System Code: 12 24 Structure: 13 N/A CONTROLLED DOCUMENT REFERENCES 15 Document No.:

From/To Document No.:

From/To UFSAR To JAF-CALC-RAD-00007 From JAF-CALC-RAD-04409 From JAF-RPT-08-00013 From JAF-CALC-MISC-04428 From FA-6E From FB-35C From FM-1A From FA-16B From FM-1C From FM-1B From FM-1E From FM-1D From FM-1K From FM-1G From FB-48A From FB-8A From Is this Design Analysis Safeguards Information? 16 Yes No If yes, see SY-AA-101-106 Does this Design Analysis contain Unverified Assumptions? 17 Yes No If yes, ATI/AR#:

This Design Analysis SUPERCEDES: 18 JAF-CALC-RAD-04410, Rev. 3 in its entirety.

Description of Revision (list changed pages when all pages of original analysis were not changed): 19 Revision 4 completely replaces Revision 3 and reperforms all new FHA analyses. The purpose of Revision 4 is to recalculate the FHA accident with the NF-500 Mast for both GNF2 & GNF3 fuel while crediting different mitigating features (secondary containment & CREVAS) for decay ranges of 0 - 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br />. The impact to the TSC is also explicitly calculated herein where necessary as well as the generation of event specific TSC /Qs.

Preparer: 20 Christopher Staum Print Name Sign Name Date Method of Review: 21 Detailed Review Alternate Calculations (attached)

Testing Reviewer: 22 Lewis Wells Print Name Sign Name Date Review Notes: 23 Independent review Peer review (For External Analyses Only)

External Approver: 24 N/A Print Name Sign Name Date Exelon Reviewer: 25 N/A Print Name Sign Name Date Independent 3rd Party Review Reqd? 26 Yes No Exelon Approver: 27 Dave Kortge Print Name Sign Name Date

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 2 REVISION HISTORY Revision Description 0

Initial issue 1

Added section to address refueling accident without post shutdown decay and SC operable. Typo for Kr-85 activity is corrected to 7.798E+05 in design input Table 1. Rev. 0 addressed 96 hrs to 30 days only.

2 Added information that allows an increased radial peaking factor for GNF2 fuel. Further made editorial changes as encountered. Substantive changes from previous revision are indicated by revision bar. IR 4040606 and Tech Eval EC 621262.

3 Revised analysis for GNF2 and GNF3 fuel designs as GE 8x8 fuel design is no longer in use at JAF. Also determined the max peaking factor for GNF2 and GNF3 fuel. Additionally, the post-LOCA model comparison has been removed from this revision. This revision was implemented with EC 631688.

4 Complete re-write of the calculation. This change incorporated a recalculation of the FHA accident with the NF-500 Mast for both GNF2 &

GNF3 fuel and the current core design requirements while crediting different mitigating features (secondary containment & CREVAS) for decay ranges of 0 - 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br />. The impact to the TSC is also explicitly calculated herein where necessary as well as the generation of event specific TSC /Qs.

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 3 TABLE OF CONTENTS Section Sheet No.

REVISION HISTORY 2

TABLE OF CONTENTS 3

1.0 PURPOSE 4

2.0 METHODOLOGY 5

3.0 ACCEPTANCE CRITERIA 8

4.0 ASSUMPTIONS 9

5.0 DESIGN INPUTS 13 6.0 COMPUTER CODES & COMPLIANCE WITH REGULATORY REQUIREMENTS 21 7.0 CALCULATIONS 22 8.0 RESULTS

SUMMARY

& CONCLUSIONS 24

9.0 REFERENCES

26

10.0 CONCLUSION

S 28 11.0 ATTACHMENTS 29 ATTACHMENT A - TSC CALCULATION [24-104 HRS AFTER REACTOR SHUTDOWN]

30 ATTACHMENT B - RADTRAD NUCLIDE INVENTORY FILE 65 ATTACHMENT C - RADTRAD RELEASE FRACTION AND TIMING FILE 75 ATTACHMENT D - RADTRAD FG 11 & 12 JAFHA_FG11&12.INP 76 ATTACHMENT E - RADTRAD OUTPUT FILES 87

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 4 1.0 PURPOSE The purpose of this analysis is to determine the Exclusion Area Boundary (EAB), Low Population Zone (LPZ) and Control Room (CR) doses resulting from a Fuel Handling Accident (FHA) occurring in the reactor building (RB). The FHA analysis is performed using the Alternative Source Term (AST), the guidance in Regulatory Guide 1.183, Appendix B, and TEDE dose criteria. The FHA scenarios consider the operability of Secondary Containment (SC) and the CR Emergency Ventilation and Air Supply System (CREVASS) depending on the assumed time of occurrence post-shutdown.

Post-Shutdown Time - 0 to 24 Hours This analysis determines the EAB, LPZ and CR doses resulting from a FHA occurring from 0 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> post-shutdown. In this early post-shutdown phase, SC operability is maintained which allows for crediting of Standby Gas Treatment System (SGTS) after a 2 minute delay for actuation, but the CREVAS system need not be operable. Therefore, this analysis supports the basis for JAF Secondary Containment Isolation associated with Technical Specifications 3.3.6.2, 3.6.4.1 through 3.6.4.3 applicability when irradiated fuel is being handled in the secondary containment and during core alterations.

Post-Shutdown Time - 24 to 104 Hours This analysis determines the EAB, LPZ and CR doses resulting from a FHA occurring from 24 to 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> post-shutdown. In this second post-shutdown phase, SC operability is not credited nor is the associated SGTS and therefore does not need to be maintained, however the CREVAS system after manual operator action is credited and must be operable. Therefore, this analysis supports the basis for JAF CREVAS associated with Technical Specifications 3.3.7.1, 3.7.3, 3.7.4, 3.8.2, 3.8.5 and 3.8.8 applicability when irradiated fuel is being handled in the secondary containment between 24 and 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> after reactor shutdown.

Post-Shutdown Time - 104 Hours or Greater This analysis determines the EAB, LPZ and CR doses resulting from a FHA occurring beyond 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> post-shutdown. In this third post-shutdown phase, neither SC operability or CREVAS are credited so they do not need to be maintained or considered operable. Therefore, this analysis demonstrates when operability no longer needs to be maintained of the previous Technical Specifications when irradiated fuel is being handled in the secondary containment at least 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> after reactor shutdown.

Technical Support Center The Technical Support Center (TSC) air intakes are located 65 feet farther west of the primary CR air intakes. The resulting TSC intake /Qs will be smaller than those for the CR air intakes. Therefore, under the same infiltration/exfiltration conditions (e.g. when no credit for Control Room Ventilation &

Filtration is taken), the CR dose is bounding for the TSC dose. However, when Control Room Ventilation & Filtration is credited, specific TSC results are generated because the TSC analyses dont credit any ventilation & filtration systems. Based on the three post-shutdown phases discussed above,

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 5 explicit TSC calculations are only needed for the Post Shutdown Time of 24 - 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> which can be found in Attachment A.

2.0 METHODOLOGY The FHA is analyzed using JAF-specific design inputs, which are compatible with the AST and TEDE dose criteria. Per NEI 99-03 (Ref. 11), all JAF plant-specific design inputs are validated to assure that they represent the as-built plant design conditions. No specific ESF function is credited in the analysis except scrubbing of the halogen activity by the water column above the postulated damaged fuel assembly, the SC systems and the CREVAS systems as documented here.

As per JAF UFSAR Section 14.8.2.1.4 on Refueling Accident, the accident is defined as a fuel assembly drop from the maximum height allowed by the fuel handling equipment onto the spent fuel pool floor or the core, resulting rupture of fuel rods.

2.1 Source Term The FHA source term originates with the activity inside the undamaged fuel rods. The bounding isotopic core inventory for both GNF2 & GNF3 fuel designs is obtained from Reference 27 (Table 5) and is listed in Table 1. The GNF2 & GNF3 source terms are determined using ORIGEN-ARP to decay the isotopic core inventory to 0, 24 and 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> after reactor shutdown at the core thermal power level of 2,587 MWt (= 102% of 2,536 MWt Rated Thermal Power [RTP]). The RADTRAD V3.03 (Ref. 2) default nuclide inventory file (NIF) is modified based on the normalized Ci/MWth. The plant-specific NIFs (JFHA_source_00.nif, JFHA_source_24.nif & JFHA_source_96.nif) are further modified to include the isotopes Kr-83m, Br-83, Br-84, I-130, Xe-131m, Xe-133m, Xe-135m and Xe-138 consistent with the approved licensing basis.

The fraction of the core fuel damaged for GNF2, a 10x10 bundle design with 85.6 equivalent full length rods, and GNF3, also a 10x10 bundle design but with 88.32 equivalent full length rods, are based on 172 damaged fuel rods in a GNF2 fuel assembly with the NF-500 mast and 169 ruptured fuel rods in a GNF3 fuel assembly with the NF-500 mast (Reference 29). With 560 fuel assemblies in the core (Reference 5), the damaged core fraction is equal to 172 / (85.6 x 560) = 0.003588 for GNF2 fuel assemblies and 169 / (88.32 x 560) = 0.003417 for GNF3 fuel assemblies. The failed fuel is assumed to have been operating at a power level associated with the radial peaking limit of 1.7. Therefore, the associated powers used in the RADTRAD Plant Scenario File (PSF) are equal to 2587 MWth x 0.003588x 1.7 ~

15.78 MWth for GNF2 fuel assemblies and 2587 MWth x 0.003417x 1.7 ~ 15.03 MWth..

For this calculation, the RADTRAD files used and the resulting FHA doses are listed in Section 8.

Because the input source term includes ORIGEN-ARP decayed isotopic inventory for 0, 24 & 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> after shutdown, for the RADTRAD input files at 0 hr & 24 hr, the delay time is set to 0 and the starting time for compartment, pathway and dose location is set to start at time 0 as well. However, for the 104 hour0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> case, the NIF file associated with 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> is used and the delay time and all associated compartment, pathway and dose location times are increased by 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

The source term is then scaled by the non-LOCA release fractions as specified by Ref. 1 Table 3 by the RFT file found in Appendix B.

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 6 2.2 Gap Activity This calculation is applicable to fuel whose burnup and power limits are bounded by those specified in RG 1.183, Footnote 11. This allows safe application of the gap activity fractions for non-LOCA events per RG 1.183, Table 3, which are as follows:

- 5% of the noble gases (excluding Kr-85)

- 10% of the Kr-85

- 5% of the halogen inventory (excluding I-131)

- 8% of the I-131

- 12% of the Alkali metal inventory The core isotopic inventory values for I-131 and Kr-85 in Tables 1, 1a & 1b have been multiplied by 1.6 and 2.0, respectively, to address the increased gap release fractions as listed in RG 1.183, Table 3. The ORIGEN-ARP isotopic core inventories (adjusted for increased gap release fractions for Kr-85 and I-131) is used to develop the appropriate RADTRAD Nuclide Inventory Files (NIF). The NIF is used as a source term input for the RADTRAD3.03 computer code (Reference 2).

2.3 Pool Decontamination Factor (DF) Model A design-basis FHA postulates dropping a spent fuel assembly over the reactor vessel, resulting in a bounding number of damaged fuel rods (Ref. 29). All activity released from the damaged rods passes through at least 23 feet of water before reaching the surface. Halogen activity scrubbing by the water column results in only 0.5% of the released halogens reaching the surface, which equates to a decontamination factor (DF) of 200 (RG 1.183 Appendix B).

This is not the case for a FHA occurring in the spent fuel pool (SFP). The SFP water level is normally maintained at about 21 feet 7 inches over the top of irradiated fuel assemblies seated in the spent fuel pool storage racks (Ref. 3) reducing the DF due to less water coverage. For GNF2 and GNF3 fuel (See Assumption 4.2), this reduced DF is evaluated (Refs. 28 and 29) in consideration of the reduced fuel damage associated with a drop in the SFP. Therefore, in conjunction with the more limiting FHA over the reactor vessel, an effective DF of 200 is used in this analysis based on a water depth of 23 feet (RG 1.183 Appendix B) by way of the RFT file reduction to iodine.

2.4 Release Model Release modeling uses the RADTRAD computer program. The compartments are the Containment (i.e., the Refueling Floor Air Space), the Environment and the Control Room. The refueling floor exhaust rate is modeled to exhaust the Reactor Building completely within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, consistent with (RG 1.183 Appendix B).

Secondary containment and its associated systems will be maintained operable per TS LCO 3.6.4.1 through LCO 3.6.4.3 (Refs. 6.1, 6.7 & 6.8) and LCO 3.3.6.2 (Ref. 6.9) during movement of irradiated fuel for the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after shutdown.

For the case where secondary containment is intact, the initial FHA release is via the RB Vent for the first 2 minutes at a rate of 99,800 cfm. The SC is maintained operable during the FHA occurring in the RB with no post-shutdown radioactive decay of fuel in the RPV. Should a FHA occur, the exhaust duct radiation monitors isolate the RB vent, which is followed by startup of the standby gas treatment system. RB air is then directed to the SGTS (Ref. 24.2) and released to the environment via the main stack. The RB vent monitor response time and subsequent termination of the vent release is

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 7 conservatively assumed to be 2 minutes. The SGTS charcoal filtration is conservatively not credited for this release path. See Figure 1 for modeling of this release pathway.

For the cases where secondary containment is not credited, the FHA release is via the RB Vent for the duration of the event at a rate of 99,800 cfm (Figure 2). As outlined in Revision 3 of this analysis, the RB Vent was considered the limiting exhaust path as compared to the RB Track bay Doors. With the same flow rate, the atmospheric dispersion /Qs from Reference 5 were shown to be an order of magnitude more limiting from the RB Vent when compared to the RB Track Bay Doors, therefore only the RV Vent is considered here.

2.5 Dose Conversion Factors The RADTRAD 3.03 dose conversion factor (DCF) file (Fgr11&12) is generated from References 7 and 8 and modified to include the DCFs for the added isotopes discussed in Section 2.1. The modified DCF file (JAFHA_FG11&12) is used in the FHA analysis. Since the DCFs for ground shine dose and dose rate are not used to evaluate the offsite and CR doses, they are set to zeros in the modified DCF file.

The CR TEDE dose is calculated using the post-FHA airborne radioactivity released through the RB vent for 0-2 hrs. The activity release rate from the damaged fuel pins is postulated to release almost all radioactive material to the environment over a 2-hour period (RG 1.183, Table 6).

The resulting doses at the EAB, LPZ and CR locations are compared in Section 8 with the regulatory allowable limits.

2.6 Control Room Dose Model The JAF Control Room is modeled with a closed volume of 101,000 ft3. Consistent with previous revisions of this analysis, the CR volume was taken as the UFSAR value because exact values of this parameter is not critical to the analysis.

Normal flow into the CR varies from 1,000 cfm to 15,000 cfm. Consistent with previous revisions of this analysis, the normal non-CREVAS CR flow rate does not significantly alter the final dose.

Therefore, the nominal flow rate of 1,920 cfm plus 10% (2,112 cfm) is modeled for when the CREVAS System is not operable. This flow path is demonstrated in Figure 3.

For the cases when SC is not operable until 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> after reactor shutdown, the CREVAS system is assumed to be operable by way of an operator Time Critical Action (Reference 23) which occurs within 8 minutes. Flow into the CR through the CREVAS system was modeled as the nominal flow rate of 1,000 CFM minus 10% (900 cfm). Also included was a combined unfiltered inleakage of 400 cfm which bounds both CR unfiltered intake and infiltered air inleakage. The filtered flow rate and unfiltered inleakage is consistent with other CREVAS modeling (Reference 12). This flow path is demonstrated in Figure 4.

The control room atmospheric dispersion factors (/Qs) for the Reactor Building Vent Exhaust Stack release point were previously developed (Reference 5) using the NRC sponsored computer code ARCON96 and guidance provided in Draft Regulatory Guide DG-1111. The control room /Qs were accepted by the staff in previous licensing proceedings.

2.7 TSC Dose Model The JAF TSC is modeled with a closed volume of 150,000 ft3 and a normal HVAC flow rate of 25,800 cfm consistent with TSC modeling in the AST LOCA analysis (Reference 13).

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 8 The TSC atmospheric dispersion factors (/Qs) for the Reactor Building Vent Exhaust Stack release point were generated consistent with the Control Room /Qs from Reference 5 and updated for the different TSC intake. This calculation can be found in Attachment A.

2.8 EAB and LPZ Dose Model CR /Qs from Ref. 5 are used for the release through the RB vent.

Turbine building (TB) /Qs are used for calculating doses at the EAB and LPZ (Ref. 9, page 16). RB vent releases were not specifically calculated in Ref. 9 because design-basis accident releases are from either the stack (LOCA and FHA) or TB surfaces (CRDA and MSLBA). However, TB /Qs would bound those of the RB Vent for offsite receptors, as described below.

The shortest on-land site boundary distance for a TB release is 975 meters. This distance was used for all northern sectors leading to the shoreline (W to ESE) and is closer to the TB than the RB Vent (Ref. 9, page 50). In the southerly directions (SE to WSW), the distance from the TB to the site boundary varies from 1290 to 2240 meters. While these distances would be slightly lower for the RB Vent, the limiting TB to EAB distance would bound the PV /Qs.

3.0 ACCEPTANCE CRITERIA The following NRC regulatory requirement and guidance documents are applicable to this FHA analysis:

RG 1.183, Table 6 10CFR50.67 Dose Acceptance Criteria are:

Regulatory Dose Limits Dose Type Control Room (30 days)

(rem TEDE)

EAB (Max 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />)

(rem TEDE)

LPZ (30 days)

(rem TEDE)

TEDE Dose 5

6.3 6.3

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 9 4.0 ASSUMPTIONS Regulatory Guide 1.183, Appendix B provides guidance on modeling assumptions that are acceptable to the NRC staff for the evaluation of the radiological consequences of a FHA. The following sections address the applicability of these modeling assumptions to this FHA analysis. These assumptions are considered validated assumptions and are identified as design inputs (See Section 5) and are incorporated in this analysis. There are no unvalidated assumptions used in this calculation.

Source Term Assumptions 4.1 Consistent with RG 1.183, Section 3.2, for non-LOCA events, the fractions of the core inventory assumed to be in the gap for the various radionuclides are given in Table 3 of RG 1.183. The release fractions from Table 3 are incorporated in Design Input 5.3.1.3 in conjunction with the core fission product inventory in Design Input 5.3.1.2 with the maximum core radial peaking factor.

Fuel rod peak burnup will not exceed the limits of RG 1.183, Footnote 11. Constellation procedure NF-AB-110-2210 (Reference 14, Section 4.5.18.1.B) requires that the core loading to be developed in accordance with NRC Regulatory Guide 1.183. There are procedural steps to ensure that:

1) peak rod burnup of the fuel is less than 62 GWD/MTU,
2) that the maximum linear heat generation rate does not exceed 6.3 kW/ft for any bundle with a peak rod burnup exceeding 54 GWD/MTU, 4.2 Consistent with RG 1.183 Appendix B, Section 1.1 the number of fuel rods damaged during the accident should be based on a conservative analysis that considers the most limiting case. For the GNF2 and GNF3 fuel designs, fuel damage information associated with the FHA with NF-500 mast is provided in Reference 29. The resulting damage is 172 ruptured fuel rods in a GNF2 fuel assembly and 169 ruptured fuel rods in a GNF3 assembly. There are 85.6 equivalent full length rods per GNF2 assembly and 88.32 equivalent full length rods per GNF3 assembly (Refs.

28 and 29).

Older fuel types, including the 8x8 assemblies that were considered in historical calculation JAF-CALC-MISC-04428, are bounded by GNF2 and GNF3 fuel since these fuel types have decayed at least one cycle and are not planned to be used in future cycles. Additionally, Table 5 of the source term calc (Ref. 27) demonstrates that the majority of isotopes released are reduced significantly after 720 hours0.00833 days <br />0.2 hours <br />0.00119 weeks <br />2.7396e-4 months <br /> of decay. Therefore, the GNF2 fuel design is used as a bounding surrogate for all prior fuel designs due to the decay of the isotopes.

4.3 Core Inventory Consistent with RG 1.183, Appendix B, the fission product release from the breached fuel is based on the fraction of fission product inventory in the gap and the estimated number of fuel rods breached.

The inventory of fission products in the reactor core that is available for gap release from damaged fuel is based on the maximum power level of 2,587 MWth, which corresponds to current fuel enrichment and burnup and is 1.02 times the current licensed rated thermal power of 2,536 MWth (Ref. 4). The gap activity in the damaged rods is assumed to be released

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 10 instantaneously to the water. The fraction of the fission product inventory comprising the gap activity is shown in Design Input 5.3.1.3.

4.4 Timing of Release Phase Consistent with RG 1.183, Section 3.3 for non-LOCA DBAs in which fuel damage is projected, the release from the fuel gap is assumed to occur instantaneously with the onset of the projected damage.

4.5 Chemical Form Design Input 5.3.1.4 specifies the elements and chemical groups to be considered. Consistent with RG 1.183, Appendix B, Section 1.3, the chemical form of radioiodine released from the fuel to the surrounding water should be assumed to be 95% cesium iodide (CsI), 4.85 percent elemental iodine, and 0.15 percent organic iodine. The CsI released from the fuel is assumed to completely dissociate in the pool water. Because of the low pH of the pool water, the iodine re-evolves as elemental iodine. The release to the pool water is assumed to occur instantaneously.

4.6 Water Depth The depth of water above the postulated damaged fuel is 23 feet or greater, thus the decontamination factors for the elemental and organic species are 285 and 1, respectively, giving an overall effective decontamination factor of 200 (i.e., 99.5% of the total iodine released from the damaged rods is retained by the water) (Design Input 5.3.2.4). This difference in decontamination factors for elemental (99.85%) and organic iodine (0.15%) species results in the iodine above the water being composed of 70% elemental and 30% organic species.

The RADTRAD model in this calculation uses 57% elemental an 43% organic as inputs instead of 70% elemental and 30% organic species. This does not impact the results as the filter efficiencies for organic and elemental iodine are the same, and there are no other removal mechanisms modeled that distinguish between the species.

As stated in Section 2.3, the FHA in the reactor cavity bounds the FHA in the SFP. This is assumed to apply to GNF2 and GNF3 fuel designs.

4.7 Noble Gases and Particulates The retention of noble gases in the water in the fuel pool or reactor cavity is negligible (i.e.,

decontamination factor of 1) (Design Input 5.3.2.5). Particulate radionuclides are assumed to be retained by the water in the fuel pool or reactor cavity (i.e., infinite decontamination factor) (RG 1.183, Appendix B).

4.8 Fuel Handling Accident within Secondary Containment For fuel handling accidents postulated to occur within secondary containment while secondary containment is open, the radioactive material that escapes from the damaged fuel to the containment is released to the environment over a 2-hour period (RG 1.183, Design Input 5.3.2.6).

Control Room Dose Consequences Regulatory Guide 1.183, Section 4.2 provides guidance to be used in determining the total effective dose equivalent (TEDE) for persons located in the Control Room (CR). The following sections address the

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 11 applicability of this guidance to the FHA analysis. These assumptions are incorporated as design inputs (See Section 5).

4.9 Consistent with RG 1.183, Section 4.2.1, the CR TEDE analysis should consider the following sources of radiation that will cause exposure to control room personnel:

Contamination of the control room atmosphere by the intake or infiltration of the radioactive material contained in the post-accident radioactive plume released from the facility (via CR air intake),

Contamination of the control room atmosphere by the intake or infiltration of airborne radioactive material from areas and structures adjacent to the control room envelope (via CR unfiltered inleakage),

Radiation shine from the external radioactive plume released from the facility (external airborne cloud),

Radiation shine from radioactive material in the secondary containment (containment shine dose),

Radiation shine from radioactive material in systems and components inside or external to the control room envelope (e.g., radioactive material buildup in recirculation filters)

(CR filter shine dose).

Note: The containment shine dose due to a FHA is insignificant compared to that due to a LOCA (Section 7.2). Similarly, the external airborne cloud dose due to a FHA is insignificant (Section 7.2). Lastly, for when the CREVAS system is activated, CR filter shine (iodines on filter) is behind concrete blocks walls at least 2.5 feet. This is considered sufficient to eliminate separate consideration of the radiation shine from the filters (Reference 15)..

4.10 Consistent with RG 1.183, Section 4.2.3, the models used to transport radioactive material into and through the control room, and the shielding models used to determine radiation dose rates from external sources, are structured to provide suitably conservative estimates of the exposure to control room personnel. The radioactive material releases and radiation levels used in the control room dose analysis used in this calculation are determined using the same source term, transport, and release assumptions used for determining the EAB and the LPZ TEDE values.

These parameters do not result in non-conservative results for the control room.

4.11 Consistent with RG 1.183, Section 4.2.6, the CR dose receptor is the hypothetical maximum exposed individual who is present in the control room for 100% of the time during the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after the event, 60% of the time between 1 and 4 days, and 40% of the time from 4 days to 30 days. For the duration of the event, the breathing rate of this individual should be assumed to be 3.5 x 10-4 cubic meters per second. These assumptions are incorporated as design inputs in Sections 5.4.3 and 5.4.4, respectively.

4.12 Consistent with RG 1.183, Section 4.4 and Table 6, the postulated CR doses should not exceed the 5 Rem TEDE criterion established in 10 CFR 50.67.

4.13 Consistent with RG 1.183, Section 4.2.4, the engineered safety features (ESF) that mitigate airborne radioactive material within the control room may be credited. The CREVAS system is credited at different points of this event.

4.14 No Credit is taken for KI pills or respirators (RG 1.183)

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 12 Offsite Dose Consequences Regulatory Guide 1.183, Section 4.1 provides guidance to be used in determining the total effective dose equivalent (TEDE) for persons located at the exclusion area boundary (EAB) and at the outer boundary of the low population zone (LPZ). The following sections address the applicability of this guidance to the FHA analysis. These assumptions are incorporated as design inputs (See Section).

4.15 Consistent with RG 1.183, Section 4.1.1 the dose calculation determines the TEDE, which is the sum of the committed effective dose equivalent (CEDE) from inhalation and the effective dose equivalent (EDE) from external exposure; and these two components of the TEDE consider all radionuclides, including progeny from the decay of parent radionuclides that are significant with regard to dose consequences and the released radioactivity.

4.16 Consistent with RG 1.183, Section 4.1.2, the exposure-to-CEDE factors for inhalation of radioactive material are derived from the data provided in ICRP Publication 30, Limits for Intakes of Radionuclides by Workers. This calculation models the CEDE dose conversion factors (DCFs) in the column headed effective yield doses in Table 2.1 of Federal Guidance Report 11, Limiting Values of Radionuclide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submersion, and Ingestion (Reference 7).

4.17 Consistent with RG 1.183, Section 4.1.4, Table III.1 of Federal Guidance Report 12, External Exposure to Radionuclides in Air, Water, and Soil (Reference 8), provides external EDE conversion factors acceptable to the NRC staff. The factors in the column headed effective, yield doses corresponding to the EDE.

4.18 Consistent with RG 1.183, Section 4.1.3, for the first 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, the breathing rate of person offsite is assumed to be 3.5 x 10-4 cubic meters per second. From 8 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> following the accident, the breathing rate is assumed to be 1.8 x 10-4 cubic meters per second. After that and until the end of the accident, the rate is assumed to be 2.3 x 10-4 cubic meters per second. This analysis conservatively models the EAB with only the conservative initial breathing rate of 3.5 x 10-4 cubic meters per second. These offsite breathing rate assumptions are listed in Sections 5.5.1 and 5.5.3.

4.19 Consistent with RG 1.183, Section 4.1.5, the TEDE is determined for the most limiting person at the EAB. The maximum EAB TEDE for any two-hour period following the start of the radioactivity release is determined and used in determining compliance with the dose criteria in 10 CFR 50.67. For the FHA the postulated EAB doses should not exceed the criteria established in RG 1.183 Table 6.

The RADTRAD3.03 Code (Reference 2) used in this analysis determines the maximum two-hour TEDE by calculating the postulated dose for a series of small time increments and performing a sliding sum over the increments for successive two-hour periods. The time increments appropriately reflect the progression of the accident to capture the peak dose interval between the start of the event and the end of radioactivity release.

4.20 Consistent with RG 1.183, Section 4.1.6, the TEDE is determined for the most limiting receptor at the outer boundary of the low population zone (LPZ) and is used in determining compliance with the dose criteria in 10 CFR 50.67. For the FHA the postulated LPZ doses should not exceed the criteria established in RG 1.183 Table 6.

4.21 Consistent with RG 1.183, Section 4.1.7, no correction is made for depletion of the effluent plume by deposition on the ground.

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 13 5.0 DESIGN INPUTS 5.1 General Considerations 5.1.1 Applicability of Prior Licensing Basis The JAF plant-specific design inputs and assumptions used in the current FHA analyses were assessed for their validity to represent the as-built condition of the plant and evaluated for their compatibility to meet the pre-AST and TEDE criteria. The analysis in this calculation ensures that assumptions, design inputs and methods are compatible with the AST and comply with RG 1.183, Appendix B requirements.

5.1.2 Credit for Accident Mitigation Features Credit should be taken only for accident mitigation features that are classified as safety-related, are required to be operable by technical specifications, are powered by emergency power sources, and are either automatically actuated or, in limited cases, have procedurally controlled manual actuation requirements. This analysis, at different times, takes credits for SC (automatically actuated and controlled by the technical specifications) and CREVAS (manually initiated by operating procedures and controlled by TS).

5.1.3 Assignment of Numeric Input Values The numeric values that are chosen as inputs to the analyses required by 10 CFR 50.67 (Ref. 20) are compatible with AST and TEDE dose criteria and selected with the objective of producing conservative radiological consequences. As a conservative alternative, the limiting value applicable to each portion of the analysis is used in the evaluation of that portion. The key design input parameter values used in the analysis are those specified in the technical specifications (Ref. 6).

5.1.4 Meteorology Considerations The control room atmospheric dispersion factors (/Qs) for the RB vent release are developed (Ref. 5) using the NRC-sponsored computer code ARCON96 and guidance provided in Draft Regulatory Guide DG-1111. The TSC atmospheric dispersion factors (/Qs) for the RB vent release are developed in Appendix A consistent with Reference 5. The EAB and LPZ /Qs were selected for the ground level release from the turbine building (MSIV leakage path) from Reference 9, which uses the JAF plant specific 8-year meteorological data and appropriate regulatory guidance.

The ground-level off-site /Qs in Reference 9 have been used in previous licensing proceedings. As stated in RIS 2006-04 (Ref. 31), Licensees may continue to use atmospheric relative concentration

(/Qs) values and methodologies from their existing licensing-basis analyses when appropriate.

5.2 Accident-Specific Design Inputs/Assumptions The design inputs utilized in the EAB, LPZ, and CR dose analyses are listed in the following sections, which incorporate the line-by-line regulatory requirements applicable to a FHA occurring in the reactor building. The design inputs are compatible with the AST and TEDE dose criteria. The design inputs and assumptions in the following sections represent the as-built design of the plant.

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 14 5.3 FHA Occurring in Reactor Building - Design Input Parameters Figure 1: RADTRAD Nodalization for FHA Occurring in RB with Secondary containment

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 15 Figure 2: RADTRAD Nodalization for FHA Occurring in RB with RB Vent Release Design Input Parameter Value Assigned Reference 5.3.1 Source Term 5.3.1.1 Core Power Level 2,587 MWt (= 102% of 2,536 MWt) 4, 6.4 & 28 5.3.1.2 Isotopic Core Inventory @ 2,587 MWth (Tables 1, 1a & 1b) 27, Table 5 Table 1: Core Inventory (Ci) at Shutdown (0 hour0 days <br />0 hours <br />0 weeks <br />0 months <br /> Decay)

Isotope Activity Isotope Activity Isotope Activity Kr-83m 1.006E+07 I-130 1.829E+06 Xe-133 1.456E+08 Kr-85^

2.722E+06 I-131^^

1.122E+08 Xe-133m 4.476E+06 Kr-85M 2.243E+07 I-132 1.024E+08 Xe-135 5.976E+07 Kr-87 4.501E+07 I-133 1.459E+08 Xe-135m 3.053E+07 Kr-88 6.105E+07 I-134 1.663E+08 Xe-138 1.291E+08 Br-83 1.004E+07 I-135 1.379E+08

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 16 Design Input Parameter Value Assigned Reference Br-84 1.889E+07 Xe-131m 9.831E+05 Table 1a: Core Inventory (Ci) at Shutdown (24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Decay)

Isotope Activity Isotope Activity Isotope Activity Kr-83m 4.087E+04 I-130 4.786E+05 Xe-133 1.405E+08 Kr-85^

2.722E+06 I-131^^

1.047E+08 Xe-133m 4.010E+06 Kr-85M 5.536E+05 I-132 8.330E+07 Xe-135 3.881E+07 Kr-87 9.520E+01 I-133 6.752E+07 Xe-135m 1.790E+06 Kr-88 1.744E+05 I-134 4.036E+00 Xe-138 2.119E-23 Br-83 1.066E+04 I-135 1.097E+07 Br-84 4.915E-07 Xe-131m 9.701E+05 Table 1b: Core Inventory (Ci) at Shutdown (96 hour0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> Decay)

Isotope Activity Isotope Activity Isotope Activity Kr-83m 4.657E-05 I-130 8.459E+03 Xe-133 1.030E+08 Kr-85^

2.722E+06 I-131^^

8.237E+07 Xe-133m 1.927E+06 Kr-85M 8.046E+00 I-132 4.398E+07 Xe-135 2.716E+05 Kr-87 8.692E-16 I-133 6.131E+06 Xe-135m 9.003E+02 Kr-88 4.062E-03 I-134 7.683E-25 Xe-138 0.000E+00 Br-83 9.934E-06 I-135 5.510E+03 Br-84 0.000E+00 Xe-131m 9.158E+05

^ Kr-85 activity is multiplied by a factor of 2 (0.1/0.05) to account for additional fractional release.

^^ I-131 activity is multiplied by a factor of 1.6 (0.08/0.05) to account for additional fractional release.

5.3.1.3 Radionuclide Release Fractions Group Fraction RG 1.183, Section 3.2, Table 3

I-131 0.08 Kr-85 0.10 Other Noble Gases 0.05 Other Halogens 0.05 Alkali Metals 0.12 5.3.1.4 Radionuclide Composition Group Elements RG 1.183, Section 3.4, Table 5

Noble Gases Xe, Kr Halogens I, Br Alkali Metals Cs, Rb 5.3.1.5 Number of Failed Fuel Rods During FHA GNF2: 172*

GNF3: 169 28, 29 & Assumption 4.2 5.3.1.6 Total Number of Fuel Assemblies in Core 560 5

5.3.17 Number of Fuel Rods Fuel Assembly GNF2: 85.6 GNF3: 88.32 28, 29 & Assumption 4.2 5.3.1.8 Irradiated Fuel Decay 0 hrs 24 hrs 120 hrs Assumed 5.3.1.9 Radial Peaking Factor 1.7 28 & Assumption 4.2

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 17 Design Input Parameter Value Assigned Reference 5.3.2 Activity Transport in Reactor Building 5.3.2.1 Pool Water Depths 23 feet RG 1.183, Appendix B, Section 2 5.3.2.2 Reactor Building Volume (ft3) 2.60E+06 Assumed**

5.3.2.3 Decontamination Factor (DF) for Iodines in Pool Water Elemental DF 285 31 Organic DF 1

5.3.2.4 Overall Effective DFs for Iodines in Pool Water Total Iodine DF 200 RG 1.183, Appendix B, Section 2 & Assumption 4.7 5.3.2.5 DF of Noble Gas 1

RG 1.183, Appendix B, Section 3 5.3.2.6 Duration of Release 2 hr RG 1.183, Appendix B, Section 5.3 5.3.2.7 Fuel Peak Burnup (MWD/MTU)

< 62,000 (rod average)

RG 1.183, Table 3, Notes 10

& 11 & Reference 3 5.3.2.8 Maximum Linear Heat Generation Rate for Peak Rod (kw/ft)

< 6.3 RG 1.183, Table 3, Note 11, Reference 14, Section 4.5.18.1.B 5.3.2.7 RB Vent Exhaust Rate /

Main Stack Exhause Rates (cfm) 99,800 See Section 2.4

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 18 5.4 Control Room Model Parameters Figure 3: JAF Control Room RADTRAD Nodalization w/out CREVAS Figure 4: JAF Control Room RADTRAD Nodalization with CREVAS CONTROL ROOM V = 101,000 ft3 0-8 Min = 2,112 cfm

>8 Min = 1,300 cfm Filtered: 0-8 Min = 0 cfm

>8 Min = 900 cfm E

N V

I R

O N

M E

N T

FHA in Unfiltered: 0-8 Min = 2,112 cfm

>8 Min = 400 cfm

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 19 Design Input Parameter Value Assigned Reference 5.4.1 CR Volume (ft3) 101,000 Assumed**

5.4.2.1 CR Normal Flow Rate (cfm)***

Nominal = 2,112 (1.920 + 10%)

10.1, 12 (page 21) 5.4.2.2 CR CREVAS Filtered Flow Rate (cfm) 900 (1,000 -10%)

12 5.4.2.3 CR CREVAS Total Unfiltered Inleakage (cfm) 400 12 (page 22) 5.4.3 CR Breathing Rate (m3/sec) 3.5E-04 RG 1.183, Section 4.2.6 5.4.4 CR Occupancy Factors Time (Hr)

RG 1.183, Section 4.2.6 0-24 100 24-96 60 96-720 40 5.4.5 CR Atmospheric Dispersion Factors (/Qs) for RB Vent Release Time (Hr)

/Qs (sec/m3) 5, Section 8.1 0-2 3.52E-03 2-8 3.31E-03 8-24 1.43E-03 24-96 7.73E-04 96-720 6.07E-04 5.4.6 CR Atmospheric Dispersion Factors (/Qs) for Main Stack Release w/ SGTS Time (Hr)

/Qs (sec/m3) 9, page 16 0-2 9.26E-07 2-8 9.26E-07 8-24 6.75E-07 24-96 3.39E-07 96-720 1.26E-07 5.5 Site Boundary Release Model Parameters 5.5.1 EAB breathing rate 3.5E-04 m3/sec RG 1.183, Section 4.2.6 5.5.2 EAB /Qs (sec/m3) 1.79E-04 9, Page 16 5.5.3 LPZ Breathing Rate (m3/sec)

Time (Hr)

(m3/sec)

RG 1.183, Section 4.1.3 0-8 3.5E-04 8-24 1.8E-04 24-720 2.3E-04 5.5.4 LPZ Atmospheric Dispersion Factors (/Qs)

Time (Hr)

/Q (sec/m3) 9, Page 16 0-8 2.00E-05 8-24 1.34E-05

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 20 Design Input Parameter Value Assigned Reference 24-96 5.59E-06 96-720 1.60E-06

  • Note: Fuel damage associated with GNF2 fuel design is used as a bounding surrogate for all legacy fuel designs. Refer to Assumption 4.2 for more detail.
    • Note: The RB and CR volumes are UFSAR values. The exact values of these parameters are not critical to the analysis. For example, the calculation models all of the RB airborne activity being released within the first two hours of the FHA event. Based on this criterion, an RB air exhaust rate is calculated.

If a different RB volume is modeled, then the RB air exhaust rate will correspondingly change to maintain the two hour criterion, and the dose results will remain the same.

      • Note: Normal CR ventilation operation allows circulation fans to increase intake flow via damper manipulation, typically during colder weather. Varying the intake flow from 1,000 cfm to 15,000 cfm in RADTRAD does not significantly alter the final dose.

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 21 6.0 COMPUTER CODES & COMPLIANCE WITH REGULATORY REQUIREMENTS 6.1 Computer Codes All computer codes used in this calculation have been approved for use with appropriate Verification and Validation (V&V) documentation. Computer codes used in this analysis include:

RADTRAD 3.03 (Reference 2): This is an NRC-sponsored code approved for use in determining control room and offsite doses from releases due to reactor accidents. This code was used by most of the AST license amendments that have been approved by the NRC. A rigorous high quality code qualification process was adopted to develop and procure the code by testing of the program elements, verification of input/output files, and examination of design specification. Therefore, the RADTRAD 3.03 computer code is considered to be qualified to comply with the quality assurance requirements of 10 CFR50, Appendix B and it can be safely used to perform the design basis accident analyses. This code was used by Constellation in various AST license amendments, which are approved by the NRC.

Therefore, the code is considered validated to be used for the JAF AST analysis. The Constellation V&V of the RADTRAD3.03 code is documented as DTSQA Number EX0009077 and is classified as SQA Level BB per IT-AA-101 (Reference 17). This code is installed for use on server nfw-ksq-01.

ARCON96 (Reference 19): This is an NRC sponsored dispersion model code approved for use in determining post-accident /Qs based on JAF plant-specific meteorological data (Reference 5). The ARCON96 code, in conjunction with the guidance in DG-1111, provides a method acceptable to the NRC staff for determining site-specific CR /Qs values for radiological habitability assessments.

ARCON96 implements improved building wake dispersion and low-wind-speed correction algorithms, use of hourly meteorological observations, sector averaging and directional-dependent dispersion conditions. /Qs are calculated for averaging periods ranging from one hour to 30 days in duration. The Constellation V&V of the ARCON96 code is documented as DTSQA Number EX0009079 and is classified as SQA Level BB per IT-AA-101 (Reference 17). This code is installed for use on server nfw-ksq-01.

6.2 Regulatory Compliance As discussed in Section 4.0, Assumptions, the analysis in this calculation complies with the line-by-line requirements in Regulatory Guide 1.183 including its Appendix B (Reference 1).

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 22 7.0 CALCULATIONS 7.1 Activity Release Rate to Environment Activity released from the spent fuel pool is uniformly distributed in the entire volume of reactor building and released to the environment over a two-hour period such that 99% of the activity released from the damaged spent fuel assembly is released to the environment through the RB vent in two hours.

In this analysis, the activity is assumed to mix with the entire reactor building volume to calculate a hypothetical maximum release rate to remove almost the entire activity (99%)

from the reactor building volume. The equation used is:

A = A0 e-t Where; A0 = Initial Activity in Source Region A = Final Activity in Source Region

= Removal Rate (vol/hr) = Q/V t = Removal Time (hr) = 2 hr Assuming that 99% of the activity is released into the environment, then A / A0 = 1 - 0.99 = 0.01 Therefore, A / A0 = 0.01 = e-t Solving for Ln (0.01) = -2 ln (e)

-4.605 = -2

= -4.605 / -2 = 2.303 volume/hr The refueling building release rate thus becomes,

= 2.303 x 2,600,000 ft3/hr = 5,987,800 ft3/hr x 1/60 hr/min

=

99,800 ft3/min 7.2 Reactor Building and External Airborne Cloud Shine Dose to the Control Room Note: the doses calculated in this section are based on older source terms but are retained to demonstrate the negligible dose to the control room operators from the shine contributions.

Post-LOCA 30-day cumulative shine dose from airborne radioactivity accumulated in the RB refueling level:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 23

= 1.42E-02 rem (Ref. 18, Table 2.3)

Post-LOCA 30-day cumulative shine dose from external airborne cloud radioactivity:

= 1.34E-04 rem (Ref. 18, Table 2.3)

Ratio of rods damaged in a FHA to rods damaged in a LOCA:

= 125 / 33600 = 0.003588 = 0.3588 %

Post-FHA 30-day cumulative shine dose from airborne radioactivity accumulated in the RB refueling level:

= 1.42E-02 rem x 0.003588

= 5.09E- 05 rem Post-FHA 30-day cumulative shine dose from external airborne cloud radioactivity:

= 1.34E-04 rem x 0.003588

= 4.81E- 07 rem

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 24 8.0 RESULTS

SUMMARY

& CONCLUSIONS 8.1 Results Summary: Less than 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Decay The purpose of this analysis is to determine the EAB, LPZ, and CR doses resulting from a FHA occurring in the RB without post-shutdown radioactive decay of fuel in the RPV and with the SC operable and CREVAS inoperable. The FHA analysis is performed using the Alternative Source Term (AST), the guidance in Regulatory Guide 1.183, Appendix B, and TEDE dose criteria.

The post-FHA EAB, LPZ, and CR doses based on the GNF2 and GNF3 fuel are summarized in the following table:

Post-FHA Post-FHA TEDE Dose (Rem)

Activity Release Receptor Location Path Control Room EAB LPZ GNF2 Fuel

(<24 hrs Decay) 2.13E+00 2.98E+00 3.33E-01 (occurs @ 0 hr)

GNF3 Fuel

(<24 hrs Decay) 2.03E+00 2.84E+00 (occurs @ 0 hr) 3.17E-01 Allowable TEDE Limit 5.00E+00 6.30E+00 6.30E+00 RADTRAD Computer Run No.

NF-500_GNF2_0-24.o0 NF-500_GNF3_0-24.o0 8.2 Results Summary: 24 - 104 hour0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> Decay The purpose of this analysis is to determine the EAB, LPZ, and CR doses resulting from a FHA occurring in the RB with >24 hr decay post-shutdown radioactive decay of fuel in the RPV, the SC inoperable and CREVAS operable. The FHA analysis is performed using the Alternative Source Term (AST), the guidance in Regulatory Guide 1.183, Appendix B, and TEDE dose criteria.

The post-FHA EAB, LPZ, and CR doses based on the GNF2 and GNF3 fuel are summarized in the following table:

Post-FHA Post-FHA TEDE Dose (Rem)

Activity Release Receptor Location Path Control Room EAB LPZ GNF2 Fuel 24-104 hrs Decay 4.95E+00 5.41E-01 6.05E-02 (occurs @ 0 hr)

GNF3 Fuel (24-104 hrs Decay) 4.71E+00 5.15E-01 (occurs @ 0 hr) 5.76E-02 Allowable TEDE Limit 5.00E+00 6.30E+00 6.30E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 25 RADTRAD Computer Run No.

NF-500_GNF2_24-104_CREVAS.o0 NF-500_GNF3_24-104_CREVAS.o0 8.3 Results Summary: Greater than 104 hour0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> Decay The purpose of this analysis is to determine the EAB, LPZ, and CR doses resulting from a FHA occurring in the RB with greater than 104 hour0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> post-shutdown radioactive decay of fuel in the RPV and with both the SC & CREVAS inoperable. The FHA analysis is performed using the Alternative Source Term (AST), the guidance in Regulatory Guide 1.183, Appendix B, and TEDE dose criteria.

The post-FHA EAB, LPZ, and CR doses based on the GNF2 and GNF3 fuel are summarized in the following table:

Post-FHA Post-FHA TEDE Dose (Rem)

Activity Release Receptor Location Path Control Room EAB LPZ GNF2 Fuel

>104 hrs Decay 4.94E+00 2.85E-01 3.19E-02 (occurs @ 0 hr)

GNF3 Fuel

(>104 hrs Decay) 4.71E+00 2.71E-01 (occurs @ 0 hr) 3.03E-02 Allowable TEDE Limit 5.00E+00 6.30E+00 6.30E+00 RADTRAD Computer Run No.

NF-500_GNF2_104.o0 NF-500_GNF3_104.o0 8.2 Conclusions The limiting FitzPatrick dose results following a Fuel Handling Accident are 4.95 Rem for the Control Room, 2.98 Rem for the EAB and 3.33E-01 Rem for the LPZ. This covers the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after shutdown in which Secondary Containment is operable,24-104 hours after shutdown in which CREVAS is operable and greater than 104 hour0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> when neither secondary containment or CREVAS are operable. All results are within their corresponding allowable TEDE limits.

Attachment A contains the post-FHA dose results for the TSC.

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 26

9.0 REFERENCES

1. U.S. NRC Regulatory Guide 1.183, Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Reactors, July 2000.
2. S.L. Humphreys et al., "RADTRAD: A Simplified Model for Radionuclide Transport and Removal and Dose Estimation," NUREG/CR-6604, USNRC, April 1998.
3. GE letter addressed to Richard Chau, NYPA, from C. H. Stoll, GE plant performance engineering, J. A. FITZPATRICK (JAFNPP) power uprate program - formal transmittal of final source term analysis results (5/2/91), Table 6.

(Note: Full-core inventory provided in Table 6 is in units of Ci/MWth. The final bundle exposure was approximately 29,000 MWD/MTU. The data in this table times 2586.5 MWth gives the core inventory in Ci).

4. U.S. NRC Regulatory Guide 1.49, Rev 1, Power Levels for Nuclear Power Plants.
5. JAF Calculation No. JAF-CALC-RAD-04409, Rev 0, Control Room /Qs Using ARCON96 Code for Post-FHA Releases from RB Track Bay and Reactor Building Vent.
6. JAFNPP Technical Specifications:

6.1. LCO 3.6.4.1, Secondary Containment Integrity 6.2. LCO 3.9.6, Reactor Pressure Vessel (RPV) Water Level 6.3. LCO 3.7.7, Spent Fuel Pool Water Level 6.4. 1.1, Definitions 6.5. 4.2.1, Fuel Assemblies 6.6. Figure 4.1-1, Site and Exclusion Area Boundaries 6.7. LCO 3.6.4.2, Secondary Containment Isolation Valves (SCIVs) 6.8. LCO 3.6.4.3, Standby Gas Treatment System 6.9. LCO 3.3.6.2, Secondary Containment Isolation Instrumentation 6.10. LCO 3.7.3, Control Room Emergency Ventilation Air Supply (CREVAS) System 6.11. LCO 3.3.7.1, Control Room Emergency Ventilation Air Supply (CREVAS) System Instrumentation

7. Federal Guidance Report 11, EPA-5201/1-88-020, Environmental Protection Agency.
8. Federal Guidance Report 12, EPA-402-R-93-081, Environmental Protection Agency.
9. JAF Calculation No. JAF-CALC-RAD-00007, Rev 2, Onsite and Offsite Post-Accident Atmospheric Dispersion Factors.
10. JAFNPP Drawings:

10.1.

FB-35C, Rev 16, Equipment Room Heating, Vent & Air Conditioning Plan EL 300-0 10.2.

FA-6E, Rev 20, Door Schedule Reactor BLDG.

10.3.

FA-16B, Rev 27, Administrative Building Floor & Roof Plans.

11. NEI 99-03, Control Room Habitability Guidance.
12. JAF-CALC-19-00005, Rev. 1, Post-LOCA EAB, LPZ, and CR Dose - AST Analysis
13. JAF-CALC-19-00007, Rev. 1, TSC Post-LOCA AST Analysis.
14. NF-AB-110-2210, Core Loading Pattern Development
15. LM-0645, Rev. 5, Re-analysis of Fuel Handling Accident (FHA) Using Alternative Source Terms
16. JAF Calculation No. JAF-CALC-RBC-02613, Rev. 0, Reactor Building Isolation Time, January 1997.
17. IT-AA-101, Rev. 17, Digital Technology Software Quality Assurance (DTSQA) Procedure

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 27

18. JAF Calculation No. JAF-CALC-RAD-00042, Rev 3 (including Addenda), Control Room Radiological Habitability under Power Uprate Conditions and CREVASS Reconfiguration.
19. NUREG/CR-6331 PNNL-10521, Rev 1, "Atmospheric Relative Concentration in Building Wakes",

May 1997

20. 10 CFR 50.67, Alternate Source Term.
21. JAFNPP Machine Location Drawings:

21.1.

FM-1A, Rev 17, Sheet 1, Plan EL 396-0 21.2.

FM-1B, Rev 18, Sheet 2, Plan EL 344-6 21.3.

FM-1C, Rev 15, Sheet 3, Plan EL 326-9 21.4.

FM-1D, Rev 34, Sheet 4, Plan EL 300-0 21.5.

FM-1E, Rev 32, Sheet 5, Plan EL 272-0 21.6.

FM-1G, Rev 11, Sheet 7, Section 1-1 21.7.

FM-1K, Rev 13, Sheet 10, Sections 4-4 & 5-5

22. Entergy Interface Control Document No. JAF-ICD-RAD-04414, Rev 0, FHA AST Analyses -

Secondary Containment Relaxation.

23. AOP-44, Dropped Fuel Assembly
24. JAFNPP Flow Diagrams:

24.1.

FB-8A, Rev 34, Sheet 1 of 1, Reactor Building Vent & Cooling System 66.

24.2.

FB-48A, Rev 34, Standby Gas Treatment System 01-125.

25. JAF Calculation No. JAF-CALC-RBC-03042, Rev. 0, Reactor Building Exfiltration During Transition from Normal to Isolation Mode, August 1998.
26. GEH-0000-0118-3592, Rev. 1, GNF2 Fuel Design Cycle-Independent Analyses For Constellation Energy Nuclear Group Nine Mile Point Nuclear Station Unit 1.
27. JAF Calculation No. JAF-CALC-RAD-04551, Rev. 1 Design Basis Source Term Core Inventories
28. TODI-JAF-EC631688-02, Rev.0, FitzPatrick Design Inputs for Re-analysis of FHA and CRDA Using AST
29. GEH Report 002N5644, Rev. 1, Fuel Damage Design Inputs Important to CRDA and FHA Design Analyses.
30. ENERCON RADTRAD, Version 3.03, Computer Software Acceptance for Project EXFP-005, Revision 0.
31. NRC Regulatory Issue Summary (RIS) 2006-04, March 7, 2006, Experience with Implementation of Alternative Source Terms
32. TODI-JAF-EC638505-04, Rev. 0, Transmittal of Design Input Information to determine TSC Intake port location in support of Fuel Handing Accident - AST Analysis

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 28

10.0 CONCLUSION

S The results of this analysis, presented in Section 8, indicate that the EAB, LPZ and CR doses are within their respective allowable limits for a FHA occurring in the reactor building with or without secondary containment operability & CREVAS, depending on the conditions specified below. This analysis provides conservative bases for the JAF Technical Specification requirements.

In general, the following conclusion is supported by the analysis:

Secondary Containment isolation must be available and operable for the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after reactor shutdown while fuel is being moved.

CREVAS and all its subsystem must remain operable from 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> after reactor shutdown while fuel is being moved. CREVAS is not required prior to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after reactor shutdown or if fuel is not being moved.

Neither Secondary Containment or CREVAS are required to be operable after 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> after reactor shutdown regardless of whether fuel is being moved.

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 29 11.0 ATTACHMENTS Attachment A - TSC Calculation [24-104 hrs After Reactor Shutdown]

Attachment B - RADTRAD Nuclide Inventory File Attachment C - RADTRAD Release Fraction and Timing File Attachment D - RADTRAD FG 11 & 12 JAFHA_FG11&12.inp Attachment E - RADTRAD Output Files

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 30 Attachment A - TSC Calculation [24-104 hrs After Reactor Shutdown]

As discussed in Section 1, the Technical Support Center (TSC) air intakes are located >65 feet farther west of the primary CR air intakes. The resulting TSC intake /Qs will be smaller than those for the CR air intakes. Therefore, under the same infiltration/exfiltration conditions (e.g. when no credit for Control Room Ventilation & Filtration is taken), the CR dose is bounding for the TSC dose. However, when Control Room Ventilation & Filtration is credited, specific TSC results are required.

Of the three post-shutdown phases analyzed above, explicit TSC calculations are needed for the Post Shutdown Time of 24 - 104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> because CREVAS is credited in the Control Room case.

Development of the TSC case can be modeled equivalent to the Control Room without CREVAS and then updated with TSC specific volume, filtration and /Qs.

The JAF TSC is modeled with a closed volume of 150,000 ft3 and a normal HVAC flow rate of 25,800 cfm consistent with TSC modeling in the AST LOCA analysis (Reference 13). The TSC atmospheric dispersion factors (/Qs) for the Reactor Building Vent Exhaust Stack release point have not been previously generated. TSC specific /Qs are generated here consistent with how the Control Room /Qs were generated in Reference 5. The TSC intake differs from the CR intake as outlined in Figure A.1 based on information from Reference 32:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 31 Figure A.1: RV (Source) & TSC Intake (Receptor Geometry) based on CR Intake.

The CR air intake X/Qs are calculated using the NRC-sponsored computer code ARCON96 and 8-years of JAF plant-specific meteorological data taken from Reference 5. As discussed in reference 5, the limiting postulated release is to occur form the RB Vent. The ARCON96 files from Reference 5 were modified to adjust the listed CR intake location with the TSC intake location outlined in reference 32.

This involved modifications to the relative elevation and N/S/E/W location relateive to the RB vent. As outlined in Reference 32, the TSC intake is located a horizontal distance of 141.68' away from the RB exhaust and a total distance (included horizontal and vertical) of 197.20' from the RB exhaust. All other aspects of the ARCON96 modeling is consistent with the existing licensing basis outlined in Reference

5.

The following TSC /Qs were generated for the TSC Intake based on a release through the Reactor Building Exhaust. A copy of the ARCON96 output file can be found at the end of this Attachment.

TSC Atmospheric Dispersion Factors (/Qs) for RB Vent Release Time (Hr)

/Qs (sec/m3) 0-2 1.80E-03 2-8 1.58E-03 8-24 6.60E-04 24-96 3.58E-04 96-720 2.83E-04 With these updated /Qs, a TSC specific run was performed. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> source term was taken from Reference 27. The volumes, flows and /Qs were updated to the TSC values mentioned above. All other input remain consistent with the FHA calcs generated in this calculation. The following results were generated. A copy of the RADTRAD computer runs can be found at the end of this Attachment.

TSC (Rem)

RADTRAD Computer Run No.

GNF2 TSC Run

(> 24 hrs) 3.79E+00 NF-500_GNF2-TSC-24hr.o0 GNF3 TSC Run

(> 24 hrs) 3.62E+00 NF-500_GNF3-TSC-24hr.o0 Allowable TEDE Limit 5.00E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 32 ARCON96 Output File Fitz_RV_TSC_updated.log Program

Title:

ARCON96.

Developed For: U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Reactor Program Management Date: June 25, 1997 11:00 a.m.

NRC Contacts: J. Y. Lee Phone: (301) 415 1080 e-mail: jyl1@nrc.gov J. J. Hayes Phone: (301) 415 3167 e-mail: jjh@nrc.gov L. A Brown Phone: (301) 415 1232 e-mail: lab2@nrc.gov Code Developer: J. V. Ramsdell Phone: (509) 372 6316 e-mail:

Code Documentation: NUREG/CR-6331 Rev. 1 The program was prepared for an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibilities for any third party's use, or the results of such use, of any portion of this program or represents that its use by such third party would not infringe privately owned rights.

Program Run 5/15/2023 at 09:06:37

              • ARCON INPUT **********

Number of Meteorological Data Files = 8 Meteorological Data File Names Fitz3085.MET Fitz3086.MET Fitz3087.MET Fitz3088.MET Fitz3089.MET Fitz3090.MET Fitz3091.MET Fitz3092.MET Height of lower wind instrument (m) = 9.1 Height of upper wind instrument (m) = 30.5 Wind speeds entered as miles per hour Ground-level release Release height (m) = 52.0 Building Area (m^2) = 2284.8

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 33 Effluent vertical velocity (m/s) =.00 Vent or stack flow (m^3/s) =.00 Vent or stack radius (m) =.00 Direction.. intake to source (deg) = 120 Wind direction sector width (deg) = 90 Wind direction window (deg) = 075 - 165 Distance to intake (m) = 43.2 Intake height (m) = 10.2 Terrain elevation difference (m) =.0 Output file names Fitz_RV_TSC_updated.log Fitz_RV_TSC_updated.cfd Minimum Wind Speed (m/s) =.5 Surface roughness length (m) =.20 Sector averaging constant = 4.3 Initial value of sigma y =.00 Initial value of sigma z =.00 Expanded output for code testing not selected Total number of hours of data processed = 70128 Hours of missing data = 1826 Hours direction in window = 14874 Hours elevated plume w/ dir. in window = 0 Hours of calm winds = 2379 Hours direction not in window or calm = 51049 DISTRIBUTION

SUMMARY

DATA BY AVERAGING INTERVAL AVER. PER. 1 2 4 8 12 24 96 168 360 720 UPPER LIM. 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 1.00E-02 LOW LIM. 1.00E-06 1.00E-06 1.00E-06 1.00E-06 1.00E-06 1.00E-06 1.00E-06 1.00E-06 1.00E-06 1.00E-06 ABOVE RANGE 0. 0. 0. 0. 0. 0. 0. 0. 0. 0.

IN RANGE 17253. 19660. 23346. 29066. 34067. 44466. 64140. 65111. 64453. 64219.

BELOW RANGE 0. 0. 0. 0. 0. 0. 0. 0. 0. 0.

ZERO 51049. 48436. 44361. 37895. 33187. 22508. 1904. 83. 0. 0.

TOTAL X/Qs 68302. 68096. 67707. 66961. 67254. 66974. 66044. 65194. 64453. 64219.

% NON ZERO 25.26 28.87 34.48 43.41 50.65 66.39 97.12 99.87 100.00 100.00 95th PERCENTILE X/Q VALUES 1.80E-03 1.77E-03 1.71E-03 1.63E-03 1.36E-03 9.85E-04 5.15E-04 4.30E-04 3.49E-04 3.14E-04 95% X/Q for standard averaging intervals 0 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 1.80E-03

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 34 2 to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> 1.58E-03 8 to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 6.60E-04 1 to 4 days 3.58E-04 4 to 30 days 2.83E-04 HOURLY VALUE RANGE MAX X/Q MIN X/Q CENTERLINE 2.22E-03 3.15E-04 SECTOR-AVERAGE 1.29E-03 1.83E-04 NORMAL PROGRAM COMPLETION

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 35 RADTRAD Output File NF-500_GNF2-TSC-24hr.o0 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 16:27:13 File information Plant file = D:\\Staum\\Fitz\\FHA\\TSC\\NF-500_GNF2-TSC-24hr.psf Inventory file = d:\\staum\\fitz\\fha\\jfha_source_24.nif Release file = d:\\staum\\fitz\\fha\\jafha_rft_with_df.rft Dose Conversion file = d:\\staum\\fitz\\fha\\jafha_fg11&12.inp Radtrad 3.03 4/15/2001 JAF FHA Occurring In Reactor Bldg With RB Vent Release, Pool DF = 200, Peaking Factor =

1.82, Decay Time = 96 Hrs, CR Normal Flow Rate =2,112 cfm, No SGTS Filtration, and Plant Vent Release @ 99,800 cfm Nuclide Inventory File:

d:\\staum\\fitz\\fha\\jfha_source_24.nif Plant Power Level:

1.5780E+01 Compartments:

3 Compartment 1:

Reactor Building 3

2.6000E+06 0

0 0

0 0

Compartment 2:

Environment 2

0.0000E+00 0

0 0

0 0

Compartment 3:

TSC 1

1.5000E+05 0

0 0

0 0

Pathways:

3 Pathway 1:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 36 Reactor Building to Environment 1

2 2

Pathway 2:

TSC Air Intake 2

3 2

Pathway 3:

TSC Exhaust to Environment 3

2 2

End of Plant Model File Scenario Description Name:

Plant Model Filename:

Source Term:

1 1 1.0000E+00 d:\\staum\\fitz\\fha\\jafha_fg11&12.inp d:\\staum\\fitz\\fha\\jafha_rft_with_df.rft 0.0000E+00 1

0.0000E+00 5.7000E-01 4.3000E-01 1.0000E+00 Overlying Pool:

0 0.0000E+00 0

0 0

0 Compartments:

3 Compartment 1:

0 1

0 0

0 0

0 0

0 Compartment 2:

0 1

0 0

0 0

0 0

0 Compartment 3:

1 1

0 0

0 0

0 0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 37 0

Pathways:

3 Pathway 1:

0 0

0 0

0 1

3 0.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 2.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 2:

0 0

0 0

0 1

2 0.0000E+00 2.5800E+04 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 3:

0 0

0 0

0 1

2 0.0000E+00 2.5800E+04 1.0000E+00 1.0000E+00 1.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Dose Locations:

3 Location 1:

Exclusion Area Boundary 2

1 2

0.0000E+00 1.7900E-04 7.2000E+02 0.0000E+00 1

2 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 38 0

Location 2:

Low Population Zone 2

1 5

0.0000E+00 2.0000E-05 8.0000E+00 1.3400E-05 2.4000E+01 5.5900E-06 9.6000E+01 1.6000E-06 7.2000E+02 0.0000E+00 1

4 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 0.0000E+00 0

Location 3:

TSC 3

0 1

2 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 1

4 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 0.0000E+00 Effective Volume Location:

1 6

0.0000E+00 1.8000E-03 2.0000E+00 1.5800E-03 8.0000E+00 6.6000E-04 2.4000E+01 3.5800E-04 9.6000E+01 2.8300E-04 7.2000E+02 0.0000E+00 Simulation Parameters:

6 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.0000E+00 7.2000E+02 0.0000E+00 Output Filename:

D:\\Staum\\Fitz\\FHA\\TSC\\NF-500_GNF2-TSC-24hr.o0 1

1 1

0 0

End of Scenario File RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 16:27:13 Plant Description

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 39 Number of Nuclides = 60 Inventory Power = 1.0000E+00 MWth Plant Power Level = 1.5780E+01 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.0000E+00

)

Name: Reactor Building Compartment volume = 2.6000E+06 (Cubic feet)

Compartment type is Normal Pathways into and out of compartment 1 Exit Pathway Number 1: Reactor Building to Environment Compartment number 2 Name: Environment Compartment type is Environment Pathways into and out of compartment 2 Inlet Pathway Number 1: Reactor Building to Environment Inlet Pathway Number 3: TSC Exhaust to Environment Exit Pathway Number 2: TSC Air Intake Compartment number 3 Name: TSC Compartment volume = 1.5000E+05 (Cubic feet)

Compartment type is Control Room Pathways into and out of compartment 3 Inlet Pathway Number 2: TSC Air Intake Exit Pathway Number 3: TSC Exhaust to Environment Total number of pathways = 3 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 16:27:13 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled Release Fractions and Timings GAP EARLY IN-VESSEL LATE RELEASE RELEASE MASS 0.003600 hr 0.0000 hrs 0.0000 hrs (gm)

NOBLES 5.0000E-02 0.0000E+00 0.0000E+00 2.355E+00 IODINE 2.5000E-04 0.0000E+00 0.0000E+00 1.439E-03 CESIUM 1.2000E-01 0.0000E+00 0.0000E+00 0.000E+00 TELLURIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 STRONTIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 BARIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 RUTHENIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 CERIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 LANTHANUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 Inventory Power = 16. MWt Nuclide Group Specific half Whole Body Inhaled Inhaled

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 40 Name Inventory life DCF Thyroid Effective (Ci/MWt) (s) (Sv-m3/Bq-s) (Sv/Bq) (Sv/Bq)

Kr-83m 1 1.580E+01 6.588E+03 1.500E-18 0.000E+00 0.000E+00 Kr-85 1 1.052E+03 3.383E+08 1.190E-16 0.000E+00 0.000E+00 Kr-85m 1 2.140E+02 1.613E+04 7.480E-15 0.000E+00 0.000E+00 Kr-87 1 3.680E-02 4.578E+03 4.120E-14 0.000E+00 0.000E+00 Kr-88 1 6.740E+01 1.022E+04 1.020E-13 0.000E+00 0.000E+00 Br-83 2 4.120E+00 8.604E+03 3.820E-16 3.290E-12 2.330E-11 Br-84 2 1.900E-10 1.908E+03 9.410E-14 3.120E-12 2.610E-11 I-130 2 1.850E+02 4.450E+04 1.040E-13 1.990E-08 7.140E-10 I-131 2 4.048E+04 6.947E+05 1.820E-14 2.920E-07 8.890E-09 I-132 2 3.220E+04 8.280E+03 1.120E-13 1.740E-09 1.030E-10 I-133 2 2.610E+04 7.488E+04 2.940E-14 4.860E-08 1.580E-09 I-134 2 1.560E-03 3.156E+03 1.300E-13 2.880E-10 3.550E-11 I-135 2 4.240E+04 2.380E+04 8.294E-14 8.460E-09 3.320E-10 Xe-131m 1 3.750E+02 1.028E+06 3.890E-16 0.000E+00 0.000E+00 Xe-133 1 5.430E+04 4.532E+05 1.560E-15 0.000E+00 0.000E+00 Xe-133m 1 1.550E+03 1.890E+05 1.370E-15 0.000E+00 0.000E+00 Xe-135 1 1.500E+04 3.272E+04 1.190E-14 0.000E+00 0.000E+00 Xe-135m 1 6.920E+02 9.174E+02 2.040E-14 0.000E+00 0.000E+00 Xe-138 1 8.190E-27 8.502E+02 5.770E-14 0.000E+00 0.000E+00 Nuclide Daughter Fraction Daughter Fraction Daughter Fraction Kr-85m Kr-85 0.21 none 0.00 none 0.00 Kr-87 Rb-87 1.00 none 0.00 none 0.00 Kr-88 Rb-88 1.00 none 0.00 none 0.00 Br-83 Kr-83m 1.00 none 0.00 none 0.00 I-131 Xe-131m 0.01 none 0.00 none 0.00 I-133 Xe-133m 0.03 Xe-133 0.97 none 0.00 I-135 Xe-135m 0.15 Xe-135 0.85 none 0.00 Xe-133m Xe-133 1.00 none 0.00 none 0.00 Xe-135 Cs-135 1.00 none 0.00 none 0.00 Xe-135m Xe-135 1.00 none 0.00 none 0.00 Xe-138 Cs-138 1.00 none 0.00 none 0.00 Iodine fractions Aerosol = 0.0000E+00 Elemental = 5.7000E-01 Organic = 4.3000E-01 COMPARTMENT DATA Compartment number 1: Reactor Building Compartment number 2: Environment Compartment number 3: TSC PATHWAY DATA Pathway number 1: Reactor Building to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 2.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 2: TSC Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 41 (cfm) Aerosol Elemental Organic 0.0000E+00 2.5800E+04 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 3: TSC Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 2.5800E+04 1.0000E+00 1.0000E+00 1.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s

  • m^-3) 0.0000E+00 1.7900E-04 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 Location Low Population Zone is in compartment 2 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 0.0000E+00 2.0000E-05 8.0000E+00 1.3400E-05 2.4000E+01 5.5900E-06 9.6000E+01 1.6000E-06 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 0.0000E+00 Location TSC is in compartment 3 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 0.0000E+00 1.8000E-03 2.0000E+00 1.5800E-03 8.0000E+00 6.6000E-04 2.4000E+01 3.5800E-04 9.6000E+01 2.8300E-04 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 Location Occupancy Factor Data Time (hr) Occupancy Factor 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 0.0000E+00 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 42 Time Time step 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.0000E+00 7.2000E+02 0.0000E+00 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 16:27:13 Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 7.1640E-04 5.1063E-02 2.2990E-03 Accumulated dose (rem) 7.1640E-04 5.1063E-02 2.2990E-03 Low Population Zone Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 8.0045E-05 5.7054E-03 2.5687E-04 Accumulated dose (rem) 8.0045E-05 5.7054E-03 2.5687E-04 TSC Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 4.9379E-06 7.3506E-03 2.3276E-04 Accumulated dose (rem) 4.9379E-06 7.3506E-03 2.3276E-04 TSC Compartment Nuclide Inventory:

Time (h) = 0.0036 Ci kg Atoms Decay Kr-83m 1.1142E-03 5.4005E-14 3.9183E+11 3.7950E+08 Kr-85 7.4284E-02 1.8934E-07 1.3414E+18 2.5288E+10 Kr-85m 1.5103E-02 1.8352E-12 1.3002E+13 5.1424E+09 Kr-87 2.5934E-06 9.1558E-17 6.3376E+08 8.8350E+05 Kr-88 4.7551E-03 3.7922E-13 2.5951E+12 1.6193E+09 Br-83 1.4531E-06 9.1981E-17 6.6738E+08 4.9486E+05 I-130 6.5303E-05 3.3483E-14 1.5511E+11 2.2233E+07 I-131 1.4292E-02 1.1528E-10 5.2994E+14 4.8653E+09 I-132 1.1356E-02 1.1002E-12 5.0193E+12 3.8675E+09 I-133 9.2138E-03 8.1336E-12 3.6828E+13 3.1368E+09 I-134 5.4921E-10 2.0588E-20 9.2523E+04 1.8716E+02 I-135 1.4964E-02 4.2610E-12 1.9008E+13 5.0949E+09 Xe-131m 2.6479E-02 3.1613E-10 1.4533E+15 9.0143E+09 Xe-133 3.8342E+00 2.0484E-08 9.2748E+16 1.3053E+12

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 43 Xe-133m 1.0944E-01 2.4391E-10 1.1044E+15 3.7258E+10 Xe-135 1.0590E+00 4.1470E-10 1.8499E+15 3.6056E+11 Xe-135m 4.9211E-02 5.4024E-13 2.4099E+12 1.6801E+10 TSC Transport Group Inventory:

Time (h) = 0.0036 Atmosphere Sump Noble gases (atoms) 1.4386E+18 0.0000E+00 Elemental I (atoms) 3.3684E+14 0.0000E+00 Organic I (atoms) 2.5411E+14 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 3.8438E-12 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 4.3339E-12 Total I (Ci) 4.9826E-02 TSC Air Intake Transport Group Inventory:

Pathway Time (h) = 0.0036 Filtered Transported Noble gases (atoms) 0.0000E+00 1.4565E+18 Elemental I (atoms) 0.0000E+00 3.4104E+14 Organic I (atoms) 0.0000E+00 2.5728E+14 Aerosols (kg) 0.0000E+00 0.0000E+00 TSC Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 0.0036 Filtered Transported Noble gases (atoms) 1.7868E+16 0.0000E+00 Elemental I (atoms) 4.1838E+12 0.0000E+00 Organic I (atoms) 3.1562E+12 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.6337E-01 1.2132E+01 5.3911E-01 Accumulated dose (rem) 1.6408E-01 1.2183E+01 5.4141E-01 Low Population Zone Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.8253E-02 1.3555E+00 6.0236E-02 Accumulated dose (rem) 1.8333E-02 1.3612E+00 6.0493E-02 TSC Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.6438E-02 1.1980E+02 3.7862E+00 Accumulated dose (rem) 7.6443E-02 1.1981E+02 3.7865E+00 TSC Compartment Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Decay Kr-83m 3.6959E-04 1.7913E-14 1.2997E+11 2.8803E+12 Kr-85 5.2426E-02 1.3363E-07 9.4672E+17 2.2689E+14 Kr-85m 7.8264E-03 9.5102E-13 6.7378E+12 4.2982E+13 Kr-87 6.1652E-07 2.1765E-17 1.5066E+08 6.2655E+09 Kr-88 2.0616E-03 1.6441E-13 1.1251E+12 1.3012E+13 Br-83 5.7478E-07 3.6384E-17 2.6398E+08 3.8985E+09 I-130 4.1207E-05 2.1128E-14 9.7874E+10 1.9434E+11 I-131 1.0014E-02 8.0778E-11 3.7134E+14 4.3578E+13 I-132 4.3914E-03 4.2543E-13 1.9409E+12 3.0321E+13 I-133 6.0842E-03 5.3709E-12 2.4319E+13 2.7709E+13 I-134 7.9960E-11 2.9974E-21 1.3471E+04 1.2080E+06 I-135 8.5662E-03 2.4392E-12 1.0881E+13 4.3552E+13

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 44 Xe-131m 1.8598E-02 2.2204E-10 1.0207E+15 8.0785E+13 Xe-133 2.6773E+00 1.4303E-08 6.4765E+16 1.1682E+16 Xe-133m 7.5237E-02 1.6768E-10 7.5923E+14 3.3223E+14 Xe-135 6.4408E-01 2.5221E-10 1.1251E+15 3.1261E+15 Xe-135m 1.6715E-03 1.8349E-14 8.1852E+10 6.5125E+13 TSC Transport Group Inventory:

Time (h) = 2.0000 Atmosphere Sump Noble gases (atoms) 1.0144E+18 0.0000E+00 Elemental I (atoms) 2.3289E+14 0.0000E+00 Organic I (atoms) 1.7569E+14 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 2.6607E-12 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 2.9456E-12 Total I (Ci) 2.9056E-02 TSC Air Intake Transport Group Inventory:

Pathway Time (h) = 2.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 3.4872E+20 Elemental I (atoms) 0.0000E+00 8.1343E+16 Organic I (atoms) 0.0000E+00 6.1364E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 TSC Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 2.0000 Filtered Transported Noble gases (atoms) 3.4915E+20 0.0000E+00 Elemental I (atoms) 8.1368E+16 0.0000E+00 Organic I (atoms) 6.1383E+16 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.6408E-01 1.2183E+01 5.4141E-01 Low Population Zone Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.8333E-02 1.3612E+00 6.0493E-02 TSC Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.1799E-04 3.8149E-01 1.2002E-02 Accumulated dose (rem) 7.6661E-02 1.2019E+02 3.7985E+00 TSC Compartment Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Decay TSC Transport Group Inventory:

Time (h) = 8.0000 Atmosphere Sump Noble gases (atoms) 1.2989E-09 0.0000E+00 Elemental I (atoms) 2.8503E-13 0.0000E+00 Organic I (atoms) 2.1502E-13 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 3.2540E-39 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 3.4872E-39 Total I (Ci) 2.5763E-29

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 45 TSC Air Intake Transport Group Inventory:

Pathway Time (h) = 8.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 3.4872E+20 Elemental I (atoms) 0.0000E+00 8.1343E+16 Organic I (atoms) 0.0000E+00 6.1364E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 TSC Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 8.0000 Filtered Transported Noble gases (atoms) 3.5014E+20 0.0000E+00 Elemental I (atoms) 8.1597E+16 0.0000E+00 Organic I (atoms) 6.1556E+16 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.6408E-01 1.2183E+01 5.4141E-01 Low Population Zone Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.8333E-02 1.3612E+00 6.0493E-02 TSC Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.0067E-31 4.6657E-28 1.4535E-29 Accumulated dose (rem) 7.6661E-02 1.2019E+02 3.7985E+00 TSC Compartment Nuclide Inventory:

Time (h) = 24.0000 Ci kg Atoms Decay TSC Transport Group Inventory:

Time (h) = 24.0000 Atmosphere Sump Noble gases (atoms) 2.5131E-81 0.0000E+00 Elemental I (atoms) 5.0686E-85 0.0000E+00 Organic I (atoms) 3.8237E-85 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 5.7436-111 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 5.9443-111 Total I (Ci) 3.2567-101 TSC Air Intake Transport Group Inventory:

Pathway Time (h) = 24.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 3.4872E+20 Elemental I (atoms) 0.0000E+00 8.1343E+16 Organic I (atoms) 0.0000E+00 6.1364E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 TSC Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 24.0000 Filtered Transported Noble gases (atoms) 3.5014E+20 0.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 46 Elemental I (atoms) 8.1597E+16 0.0000E+00 Organic I (atoms) 6.1556E+16 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.6408E-01 1.2183E+01 5.4141E-01 Low Population Zone Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.8333E-02 1.3612E+00 6.0493E-02 TSC Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 6.2999-103 2.3460E-99 7.2349-101 Accumulated dose (rem) 7.6661E-02 1.2019E+02 3.7985E+00 TSC Compartment Nuclide Inventory:

Time (h) = 96.0000 Ci kg Atoms Decay TSC Transport Group Inventory:

Time (h) = 96.0000 Atmosphere Sump Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 0.0000E+00 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 0.0000E+00 Total I (Ci) 0.0000E+00 TSC Air Intake Transport Group Inventory:

Pathway Time (h) = 96.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 3.4872E+20 Elemental I (atoms) 0.0000E+00 8.1343E+16 Organic I (atoms) 0.0000E+00 6.1364E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 TSC Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 96.0000 Filtered Transported Noble gases (atoms) 3.5014E+20 0.0000E+00 Elemental I (atoms) 8.1597E+16 0.0000E+00 Organic I (atoms) 6.1556E+16 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.6408E-01 1.2183E+01 5.4141E-01 Low Population Zone Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.8333E-02 1.3612E+00 6.0493E-02

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 47 TSC Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 7.6661E-02 1.2019E+02 3.7985E+00 TSC Compartment Nuclide Inventory:

Time (h) = 720.0000 Ci kg Atoms Decay TSC Transport Group Inventory:

Time (h) = 720.0000 Atmosphere Sump Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 0.0000E+00 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 0.0000E+00 Total I (Ci) 0.0000E+00 TSC Air Intake Transport Group Inventory:

Pathway Time (h) = 720.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 3.4872E+20 Elemental I (atoms) 0.0000E+00 8.1343E+16 Organic I (atoms) 0.0000E+00 6.1364E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 TSC Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 720.0000 Filtered Transported Noble gases (atoms) 3.5014E+20 0.0000E+00 Elemental I (atoms) 8.1597E+16 0.0000E+00 Organic I (atoms) 6.1556E+16 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 838 I-131 Summary Reactor Building Environment TSC Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 0.000 2.4628E+01 1.5759E-02 3.4474E-04 0.004 1.5903E+02 6.6018E-01 1.4292E-02 0.400 6.3735E+01 9.5790E+01 3.8481E-01 0.700 3.1904E+01 1.2757E+02 2.0013E-01 1.000 1.5970E+01 1.4347E+02 1.0052E-01 1.300 7.9944E+00 1.5143E+02 5.0333E-02 1.600 4.0018E+00 1.5542E+02 2.5196E-02 1.900 2.0032E+00 1.5741E+02 1.2613E-02 2.000 1.5905E+00 1.5783E+02 1.0014E-02 2.300 1.5888E+00 1.5783E+02 4.5246E-04 2.600 1.5871E+00 1.5783E+02 2.0443E-05 2.900 1.5854E+00 1.5783E+02 9.2362E-07 3.200 1.5837E+00 1.5783E+02 4.1730E-08 3.500 1.5820E+00 1.5783E+02 1.8854E-09 3.800 1.5803E+00 1.5783E+02 8.5185E-11 4.100 1.5786E+00 1.5783E+02 3.8487E-12 4.400 1.5769E+00 1.5783E+02 1.7389E-13 4.700 1.5752E+00 1.5783E+02 7.8565E-15

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 48 5.000 1.5735E+00 1.5783E+02 3.5497E-16 5.300 1.5718E+00 1.5783E+02 1.6038E-17 5.600 1.5701E+00 1.5783E+02 7.2460E-19 5.900 1.5684E+00 1.5783E+02 3.2738E-20 6.200 1.5667E+00 1.5783E+02 1.4791E-21 6.500 1.5650E+00 1.5783E+02 6.6829E-23 6.800 1.5633E+00 1.5783E+02 3.0194E-24 7.100 1.5617E+00 1.5783E+02 1.3642E-25 7.400 1.5600E+00 1.5783E+02 6.1636E-27 7.700 1.5583E+00 1.5783E+02 2.7848E-28 8.000 1.5566E+00 1.5783E+02 1.2582E-29 8.300 1.5549E+00 1.5783E+02 5.6846E-31 8.600 1.5533E+00 1.5783E+02 2.5684E-32 8.900 1.5516E+00 1.5783E+02 1.1604E-33 9.200 1.5499E+00 1.5783E+02 5.2428E-35 9.500 1.5483E+00 1.5783E+02 2.3688E-36 9.800 1.5466E+00 1.5783E+02 1.0702E-37 10.100 1.5449E+00 1.5783E+02 4.8354E-39 10.400 1.5433E+00 1.5783E+02 2.1847E-40 24.000 1.4697E+00 1.5783E+02 2.3119-101 96.000 1.1347E+00 1.5783E+02 0.0000E+00 720.000 1.2062E-01 1.5783E+02 0.0000E+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone TSC Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 0.000 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.004 5.1063E-02 2.2990E-03 5.7054E-03 2.5687E-04 7.3506E-03 2.3276E-04 0.400 7.4056E+00 3.3157E-01 8.2744E-01 3.7047E-02 5.8329E+01 1.8455E+00 0.700 9.8564E+00 4.3988E-01 1.1013E+00 4.9148E-02 8.9589E+01 2.8332E+00 1.000 1.1081E+01 4.9357E-01 1.2381E+00 5.5148E-02 1.0548E+02 3.3349E+00 1.300 1.1693E+01 5.2023E-01 1.3064E+00 5.8126E-02 1.1344E+02 3.5858E+00 1.600 1.1998E+01 5.3348E-01 1.3406E+00 5.9606E-02 1.1741E+02 3.7110E+00 1.900 1.2151E+01 5.4006E-01 1.3577E+00 6.0342E-02 1.1940E+02 3.7736E+00 2.000 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.1981E+02 3.7865E+00 2.300 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2017E+02 3.7979E+00 2.600 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7984E+00 2.900 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 3.200 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 3.500 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 3.800 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 4.100 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 4.400 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 4.700 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 5.000 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 5.300 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 5.600 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 5.900 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 6.200 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 6.500 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 6.800 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 7.100 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 7.400 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 7.700 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 8.000 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 8.300 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 8.600 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 8.900 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 9.200 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 9.500 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 9.800 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 49 10.100 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 10.400 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 24.000 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 96.000 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 720.000 1.2183E+01 5.4141E-01 1.3612E+00 6.0493E-02 1.2019E+02 3.7985E+00 Worst Two-Hour Doses Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 0.0 1.6408E-01 1.2183E+01 5.4141E-01

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 50 RADTRAD Output File NF-500_GNF3-TSC-24hr.o0 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 16:29:02 File information Plant file = D:\\Staum\\Fitz\\FHA\\TSC\\NF-500_GNF3-TSC-24hr.psf Inventory file = D:\\Staum\\Fitz\\FHA\\JFHA_source_24.nif Release file = D:\\Staum\\Fitz\\FHA\\jafha_rft_with_DF.rft Dose Conversion file = D:\\Staum\\Fitz\\FHA\\JAFHA_FG11&12.inp Radtrad 3.03 4/15/2001 JAF FHA Occurring In Reactor Bldg With RB Vent Release, Pool DF = 200, Peaking Factor =

1.82, Decay Time = 96 Hrs, CR Normal Flow Rate =2,112 cfm, No SGTS Filtration, and Plant Vent Release @ 99,800 cfm Nuclide Inventory File:

D:\\Staum\\Fitz\\FHA\\JFHA_source_24.nif Plant Power Level:

1.5028E+01 Compartments:

3 Compartment 1:

Reactor Building 3

2.6000E+06 0

0 0

0 0

Compartment 2:

Environment 2

0.0000E+00 0

0 0

0 0

Compartment 3:

TSC 1

1.5000E+05 0

0 0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 51 0

0 Pathways:

3 Pathway 1:

Reactor Building to Environment 1

2 2

Pathway 2:

TSC Air Intake 2

3 2

Pathway 3:

TSC Exhaust to Environment 3

2 2

End of Plant Model File Scenario Description Name:

Plant Model Filename:

Source Term:

1 1 1.0000E+00 D:\\Staum\\Fitz\\FHA\\JAFHA_FG11&12.inp D:\\Staum\\Fitz\\FHA\\jafha_rft_with_DF.rft 0.0000E+00 1

0.0000E+00 5.7000E-01 4.3000E-01 1.0000E+00 Overlying Pool:

0 0.0000E+00 0

0 0

0 Compartments:

3 Compartment 1:

0 1

0 0

0 0

0 0

0 Compartment 2:

0 1

0 0

0 0

0 0

0 Compartment 3:

1 1

0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 52 0

0 0

0 0

0 Pathways:

3 Pathway 1:

0 0

0 0

0 1

3 0.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 2.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 2:

0 0

0 0

0 1

2 0.0000E+00 2.5800E+04 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 3:

0 0

0 0

0 1

2 0.0000E+00 2.5800E+04 1.0000E+00 1.0000E+00 1.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Dose Locations:

3 Location 1:

Exclusion Area Boundary 2

1 2

0.0000E+00 1.7900E-04

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 53 7.2000E+02 0.0000E+00 1

2 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 0

Location 2:

Low Population Zone 2

1 5

0.0000E+00 2.0000E-05 8.0000E+00 1.3400E-05 2.4000E+01 5.5900E-06 9.6000E+01 1.6000E-06 7.2000E+02 0.0000E+00 1

4 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 0.0000E+00 0

Location 3:

TSC 3

0 1

2 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 1

4 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 0.0000E+00 Effective Volume Location:

1 6

0.0000E+00 1.8000E-03 2.0000E+00 1.5800E-03 8.0000E+00 6.6000E-04 2.4000E+01 3.5800E-04 9.6000E+01 2.8300E-04 7.2000E+02 0.0000E+00 Simulation Parameters:

6 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.0000E+00 7.2000E+02 0.0000E+00 Output Filename:

D:\\Staum\\Fitz\\FHA\\TSC\\RPF 170 - No CREVAS\\GNF3-TSC_170.o0 1

1 1

0 0

End of Scenario File

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 54 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 16:29:02 Plant Description Number of Nuclides = 60 Inventory Power = 1.0000E+00 MWth Plant Power Level = 1.5028E+01 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.0000E+00

)

Name: Reactor Building Compartment volume = 2.6000E+06 (Cubic feet)

Compartment type is Normal Pathways into and out of compartment 1 Exit Pathway Number 1: Reactor Building to Environment Compartment number 2 Name: Environment Compartment type is Environment Pathways into and out of compartment 2 Inlet Pathway Number 1: Reactor Building to Environment Inlet Pathway Number 3: TSC Exhaust to Environment Exit Pathway Number 2: TSC Air Intake Compartment number 3 Name: TSC Compartment volume = 1.5000E+05 (Cubic feet)

Compartment type is Control Room Pathways into and out of compartment 3 Inlet Pathway Number 2: TSC Air Intake Exit Pathway Number 3: TSC Exhaust to Environment Total number of pathways = 3 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 16:29:02 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled Release Fractions and Timings GAP EARLY IN-VESSEL LATE RELEASE RELEASE MASS 0.003600 hr 0.0000 hrs 0.0000 hrs (gm)

NOBLES 5.0000E-02 0.0000E+00 0.0000E+00 2.243E+00 IODINE 2.5000E-04 0.0000E+00 0.0000E+00 1.371E-03 CESIUM 1.2000E-01 0.0000E+00 0.0000E+00 0.000E+00 TELLURIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 STRONTIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 BARIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 RUTHENIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 CERIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 55 LANTHANUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 Inventory Power = 15. MWt Nuclide Group Specific half Whole Body Inhaled Inhaled Name Inventory life DCF Thyroid Effective (Ci/MWt) (s) (Sv-m3/Bq-s) (Sv/Bq) (Sv/Bq)

Kr-83m 1 1.580E+01 6.588E+03 1.500E-18 0.000E+00 0.000E+00 Kr-85 1 1.052E+03 3.383E+08 1.190E-16 0.000E+00 0.000E+00 Kr-85m 1 2.140E+02 1.613E+04 7.480E-15 0.000E+00 0.000E+00 Kr-87 1 3.680E-02 4.578E+03 4.120E-14 0.000E+00 0.000E+00 Kr-88 1 6.740E+01 1.022E+04 1.020E-13 0.000E+00 0.000E+00 Br-83 2 4.120E+00 8.604E+03 3.820E-16 3.290E-12 2.330E-11 Br-84 2 1.900E-10 1.908E+03 9.410E-14 3.120E-12 2.610E-11 I-130 2 1.850E+02 4.450E+04 1.040E-13 1.990E-08 7.140E-10 I-131 2 4.048E+04 6.947E+05 1.820E-14 2.920E-07 8.890E-09 I-132 2 3.220E+04 8.280E+03 1.120E-13 1.740E-09 1.030E-10 I-133 2 2.610E+04 7.488E+04 2.940E-14 4.860E-08 1.580E-09 I-134 2 1.560E-03 3.156E+03 1.300E-13 2.880E-10 3.550E-11 I-135 2 4.240E+04 2.380E+04 8.294E-14 8.460E-09 3.320E-10 Xe-131m 1 3.750E+02 1.028E+06 3.890E-16 0.000E+00 0.000E+00 Xe-133 1 5.430E+04 4.532E+05 1.560E-15 0.000E+00 0.000E+00 Xe-133m 1 1.550E+03 1.890E+05 1.370E-15 0.000E+00 0.000E+00 Xe-135 1 1.500E+04 3.272E+04 1.190E-14 0.000E+00 0.000E+00 Xe-135m 1 6.920E+02 9.174E+02 2.040E-14 0.000E+00 0.000E+00 Xe-138 1 8.190E-27 8.502E+02 5.770E-14 0.000E+00 0.000E+00 Nuclide Daughter Fraction Daughter Fraction Daughter Fraction Kr-85m Kr-85 0.21 none 0.00 none 0.00 Kr-87 Rb-87 1.00 none 0.00 none 0.00 Kr-88 Rb-88 1.00 none 0.00 none 0.00 Br-83 Kr-83m 1.00 none 0.00 none 0.00 I-131 Xe-131m 0.01 none 0.00 none 0.00 I-133 Xe-133m 0.03 Xe-133 0.97 none 0.00 I-135 Xe-135m 0.15 Xe-135 0.85 none 0.00 Xe-133m Xe-133 1.00 none 0.00 none 0.00 Xe-135 Cs-135 1.00 none 0.00 none 0.00 Xe-135m Xe-135 1.00 none 0.00 none 0.00 Xe-138 Cs-138 1.00 none 0.00 none 0.00 Iodine fractions Aerosol = 0.0000E+00 Elemental = 5.7000E-01 Organic = 4.3000E-01 COMPARTMENT DATA Compartment number 1: Reactor Building Compartment number 2: Environment Compartment number 3: TSC PATHWAY DATA Pathway number 1: Reactor Building to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 2.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 56 Pathway number 2: TSC Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 2.5800E+04 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 3: TSC Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 2.5800E+04 1.0000E+00 1.0000E+00 1.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s

  • m^-3) 0.0000E+00 1.7900E-04 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 Location Low Population Zone is in compartment 2 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 0.0000E+00 2.0000E-05 8.0000E+00 1.3400E-05 2.4000E+01 5.5900E-06 9.6000E+01 1.6000E-06 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 0.0000E+00 Location TSC is in compartment 3 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 0.0000E+00 1.8000E-03 2.0000E+00 1.5800E-03 8.0000E+00 6.6000E-04 2.4000E+01 3.5800E-04 9.6000E+01 2.8300E-04 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 Location Occupancy Factor Data Time (hr) Occupancy Factor 0.0000E+00 1.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 57 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 0.0000E+00 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.0000E+00 7.2000E+02 0.0000E+00 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 16:29:02 Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 6.8226E-04 4.8630E-02 2.1895E-03 Accumulated dose (rem) 6.8226E-04 4.8630E-02 2.1895E-03 Low Population Zone Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 7.6230E-05 5.4335E-03 2.4463E-04 Accumulated dose (rem) 7.6230E-05 5.4335E-03 2.4463E-04 TSC Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 4.7026E-06 7.0003E-03 2.2167E-04 Accumulated dose (rem) 4.7026E-06 7.0003E-03 2.2167E-04 TSC Compartment Nuclide Inventory:

Time (h) = 0.0036 Ci kg Atoms Decay Kr-83m 1.0611E-03 5.1431E-14 3.7316E+11 3.6141E+08 Kr-85 7.0744E-02 1.8032E-07 1.2775E+18 2.4083E+10 Kr-85m 1.4383E-02 1.7477E-12 1.2382E+13 4.8973E+09 Kr-87 2.4698E-06 8.7195E-17 6.0356E+08 8.4139E+05 Kr-88 4.5285E-03 3.6114E-13 2.4714E+12 1.5421E+09 Br-83 1.3838E-06 8.7598E-17 6.3557E+08 4.7128E+05 I-130 6.2191E-05 3.1887E-14 1.4771E+11 2.1173E+07 I-131 1.3611E-02 1.0979E-10 5.0469E+14 4.6335E+09 I-132 1.0815E-02 1.0478E-12 4.7801E+12 3.6832E+09 I-133 8.7747E-03 7.7460E-12 3.5073E+13 2.9873E+09

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 58 I-134 5.2304E-10 1.9606E-20 8.8114E+04 1.7824E+02 I-135 1.4251E-02 4.0580E-12 1.8102E+13 4.8521E+09 Xe-131m 2.5217E-02 3.0106E-10 1.3840E+15 8.5848E+09 Xe-133 3.6515E+00 1.9508E-08 8.8329E+16 1.2431E+12 Xe-133m 1.0423E-01 2.3229E-10 1.0518E+15 3.5483E+10 Xe-135 1.0086E+00 3.9494E-10 1.7618E+15 3.4337E+11 Xe-135m 4.6866E-02 5.1449E-13 2.2951E+12 1.6000E+10 TSC Transport Group Inventory:

Time (h) = 0.0036 Atmosphere Sump Noble gases (atoms) 1.3701E+18 0.0000E+00 Elemental I (atoms) 3.2079E+14 0.0000E+00 Organic I (atoms) 2.4200E+14 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 3.6606E-12 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 4.1274E-12 Total I (Ci) 4.7451E-02 TSC Air Intake Transport Group Inventory:

Pathway Time (h) = 0.0036 Filtered Transported Noble gases (atoms) 0.0000E+00 1.3871E+18 Elemental I (atoms) 0.0000E+00 3.2479E+14 Organic I (atoms) 0.0000E+00 2.4502E+14 Aerosols (kg) 0.0000E+00 0.0000E+00 TSC Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 0.0036 Filtered Transported Noble gases (atoms) 1.7016E+16 0.0000E+00 Elemental I (atoms) 3.9844E+12 0.0000E+00 Organic I (atoms) 3.0058E+12 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.5558E-01 1.1553E+01 5.1342E-01 Accumulated dose (rem) 1.5626E-01 1.1602E+01 5.1561E-01 Low Population Zone Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.7383E-02 1.2909E+00 5.7365E-02 Accumulated dose (rem) 1.7460E-02 1.2963E+00 5.7610E-02 TSC Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.2795E-02 1.1409E+02 3.6058E+00 Accumulated dose (rem) 7.2800E-02 1.1410E+02 3.6060E+00 TSC Compartment Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Decay Kr-83m 3.5197E-04 1.7060E-14 1.2378E+11 2.7430E+12 Kr-85 4.9928E-02 1.2726E-07 9.0161E+17 2.1607E+14 Kr-85m 7.4535E-03 9.0570E-13 6.4167E+12 4.0934E+13 Kr-87 5.8714E-07 2.0728E-17 1.4348E+08 5.9669E+09 Kr-88 1.9634E-03 1.5658E-13 1.0715E+12 1.2392E+13 Br-83 5.4738E-07 3.4650E-17 2.5140E+08 3.7128E+09 I-130 3.9243E-05 2.0121E-14 9.3210E+10 1.8507E+11 I-131 9.5372E-03 7.6929E-11 3.5365E+14 4.1501E+13

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 59 I-132 4.1821E-03 4.0516E-13 1.8484E+12 2.8876E+13 I-133 5.7943E-03 5.1149E-12 2.3160E+13 2.6388E+13 I-134 7.6149E-11 2.8545E-21 1.2829E+04 1.1504E+06 I-135 8.1580E-03 2.3230E-12 1.0363E+13 4.1476E+13 Xe-131m 1.7712E-02 2.1146E-10 9.7209E+14 7.6935E+13 Xe-133 2.5497E+00 1.3622E-08 6.1678E+16 1.1125E+16 Xe-133m 7.1652E-02 1.5969E-10 7.2305E+14 3.1640E+14 Xe-135 6.1338E-01 2.4019E-10 1.0715E+15 2.9772E+15 Xe-135m 1.5918E-03 1.7475E-14 7.7952E+10 6.2021E+13 TSC Transport Group Inventory:

Time (h) = 2.0000 Atmosphere Sump Noble gases (atoms) 9.6606E+17 0.0000E+00 Elemental I (atoms) 2.2179E+14 0.0000E+00 Organic I (atoms) 1.6732E+14 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 2.5339E-12 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 2.8052E-12 Total I (Ci) 2.7672E-02 TSC Air Intake Transport Group Inventory:

Pathway Time (h) = 2.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 3.3210E+20 Elemental I (atoms) 0.0000E+00 7.7466E+16 Organic I (atoms) 0.0000E+00 5.8439E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 TSC Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 2.0000 Filtered Transported Noble gases (atoms) 3.3251E+20 0.0000E+00 Elemental I (atoms) 7.7490E+16 0.0000E+00 Organic I (atoms) 5.8458E+16 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.5626E-01 1.1602E+01 5.1561E-01 Low Population Zone Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.7460E-02 1.2963E+00 5.7610E-02 TSC Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.0760E-04 3.6331E-01 1.1430E-02 Accumulated dose (rem) 7.3007E-02 1.1446E+02 3.6174E+00 TSC Compartment Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Decay TSC Transport Group Inventory:

Time (h) = 8.0000 Atmosphere Sump Noble gases (atoms) 1.2370E-09 0.0000E+00 Elemental I (atoms) 2.7144E-13 0.0000E+00 Organic I (atoms) 2.0477E-13 0.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 60 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 3.0989E-39 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 3.3210E-39 Total I (Ci) 2.4535E-29 TSC Air Intake Transport Group Inventory:

Pathway Time (h) = 8.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 3.3210E+20 Elemental I (atoms) 0.0000E+00 7.7466E+16 Organic I (atoms) 0.0000E+00 5.8439E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 TSC Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 8.0000 Filtered Transported Noble gases (atoms) 3.3346E+20 0.0000E+00 Elemental I (atoms) 7.7708E+16 0.0000E+00 Organic I (atoms) 5.8622E+16 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.5626E-01 1.1602E+01 5.1561E-01 Low Population Zone Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.7460E-02 1.2963E+00 5.7610E-02 TSC Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.9110E-31 4.4434E-28 1.3843E-29 Accumulated dose (rem) 7.3007E-02 1.1446E+02 3.6174E+00 TSC Compartment Nuclide Inventory:

Time (h) = 24.0000 Ci kg Atoms Decay TSC Transport Group Inventory:

Time (h) = 24.0000 Atmosphere Sump Noble gases (atoms) 2.3933E-81 0.0000E+00 Elemental I (atoms) 4.8271E-85 0.0000E+00 Organic I (atoms) 3.6415E-85 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 5.4699-111 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 5.6611-111 Total I (Ci) 3.1015-101 TSC Air Intake Transport Group Inventory:

Pathway Time (h) = 24.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 3.3210E+20 Elemental I (atoms) 0.0000E+00 7.7466E+16 Organic I (atoms) 0.0000E+00 5.8439E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 TSC Exhaust to Environment Transport Group Inventory:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 61 Pathway Time (h) = 24.0000 Filtered Transported Noble gases (atoms) 3.3346E+20 0.0000E+00 Elemental I (atoms) 7.7708E+16 0.0000E+00 Organic I (atoms) 5.8622E+16 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.5626E-01 1.1602E+01 5.1561E-01 Low Population Zone Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.7460E-02 1.2963E+00 5.7610E-02 TSC Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 5.9996-103 2.2342E-99 6.8901-101 Accumulated dose (rem) 7.3007E-02 1.1446E+02 3.6174E+00 TSC Compartment Nuclide Inventory:

Time (h) = 96.0000 Ci kg Atoms Decay TSC Transport Group Inventory:

Time (h) = 96.0000 Atmosphere Sump Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 0.0000E+00 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 0.0000E+00 Total I (Ci) 0.0000E+00 TSC Air Intake Transport Group Inventory:

Pathway Time (h) = 96.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 3.3210E+20 Elemental I (atoms) 0.0000E+00 7.7466E+16 Organic I (atoms) 0.0000E+00 5.8439E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 TSC Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 96.0000 Filtered Transported Noble gases (atoms) 3.3346E+20 0.0000E+00 Elemental I (atoms) 7.7708E+16 0.0000E+00 Organic I (atoms) 5.8622E+16 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.5626E-01 1.1602E+01 5.1561E-01 Low Population Zone Doses:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 62 Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.7460E-02 1.2963E+00 5.7610E-02 TSC Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 7.3007E-02 1.1446E+02 3.6174E+00 TSC Compartment Nuclide Inventory:

Time (h) = 720.0000 Ci kg Atoms Decay TSC Transport Group Inventory:

Time (h) = 720.0000 Atmosphere Sump Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 0.0000E+00 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 0.0000E+00 Total I (Ci) 0.0000E+00 TSC Air Intake Transport Group Inventory:

Pathway Time (h) = 720.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 3.3210E+20 Elemental I (atoms) 0.0000E+00 7.7466E+16 Organic I (atoms) 0.0000E+00 5.8439E+16 Aerosols (kg) 0.0000E+00 0.0000E+00 TSC Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 720.0000 Filtered Transported Noble gases (atoms) 3.3346E+20 0.0000E+00 Elemental I (atoms) 7.7708E+16 0.0000E+00 Organic I (atoms) 5.8622E+16 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 838 I-131 Summary Reactor Building Environment TSC Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 0.000 2.3455E+01 1.5008E-02 3.2831E-04 0.004 1.5145E+02 6.2872E-01 1.3611E-02 0.400 6.0698E+01 9.1225E+01 3.6647E-01 0.700 3.0384E+01 1.2149E+02 1.9060E-01 1.000 1.5209E+01 1.3663E+02 9.5731E-02 1.300 7.6134E+00 1.4422E+02 4.7935E-02 1.600 3.8111E+00 1.4801E+02 2.3996E-02 1.900 1.9077E+00 1.4991E+02 1.2012E-02 2.000 1.5147E+00 1.5031E+02 9.5372E-03 2.300 1.5131E+00 1.5031E+02 4.3090E-04 2.600 1.5115E+00 1.5031E+02 1.9469E-05 2.900 1.5098E+00 1.5031E+02 8.7961E-07 3.200 1.5082E+00 1.5031E+02 3.9742E-08 3.500 1.5066E+00 1.5031E+02 1.7956E-09

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 63 3.800 1.5050E+00 1.5031E+02 8.1125E-11 4.100 1.5033E+00 1.5031E+02 3.6653E-12 4.400 1.5017E+00 1.5031E+02 1.6560E-13 4.700 1.5001E+00 1.5031E+02 7.4821E-15 5.000 1.4985E+00 1.5031E+02 3.3805E-16 5.300 1.4969E+00 1.5031E+02 1.5273E-17 5.600 1.4953E+00 1.5031E+02 6.9007E-19 5.900 1.4937E+00 1.5031E+02 3.1178E-20 6.200 1.4921E+00 1.5031E+02 1.4086E-21 6.500 1.4904E+00 1.5031E+02 6.3644E-23 6.800 1.4888E+00 1.5031E+02 2.8755E-24 7.100 1.4872E+00 1.5031E+02 1.2992E-25 7.400 1.4856E+00 1.5031E+02 5.8698E-27 7.700 1.4840E+00 1.5031E+02 2.6521E-28 8.000 1.4824E+00 1.5031E+02 1.1982E-29 8.300 1.4808E+00 1.5031E+02 5.4137E-31 8.600 1.4792E+00 1.5031E+02 2.4460E-32 8.900 1.4776E+00 1.5031E+02 1.1051E-33 9.200 1.4761E+00 1.5031E+02 4.9930E-35 9.500 1.4745E+00 1.5031E+02 2.2559E-36 9.800 1.4729E+00 1.5031E+02 1.0192E-37 10.100 1.4713E+00 1.5031E+02 4.6050E-39 10.400 1.4697E+00 1.5031E+02 2.0806E-40 24.000 1.3996E+00 1.5031E+02 2.2017-101 96.000 1.0807E+00 1.5031E+02 0.0000E+00 720.000 1.1487E-01 1.5031E+02 0.0000E+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone TSC Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 0.000 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.004 4.8630E-02 2.1895E-03 5.4335E-03 2.4463E-04 7.0003E-03 2.2167E-04 0.400 7.0527E+00 3.1577E-01 7.8801E-01 3.5282E-02 5.5549E+01 1.7575E+00 0.700 9.3867E+00 4.1891E-01 1.0488E+00 4.6806E-02 8.5319E+01 2.6982E+00 1.000 1.0553E+01 4.7005E-01 1.1791E+00 5.2520E-02 1.0046E+02 3.1760E+00 1.300 1.1135E+01 4.9544E-01 1.2442E+00 5.5356E-02 1.0803E+02 3.4149E+00 1.600 1.1427E+01 5.0805E-01 1.2767E+00 5.6766E-02 1.1181E+02 3.5342E+00 1.900 1.1572E+01 5.1432E-01 1.2930E+00 5.7466E-02 1.1371E+02 3.5937E+00 2.000 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1410E+02 3.6060E+00 2.300 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1444E+02 3.6169E+00 2.600 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 2.900 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 3.200 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 3.500 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 3.800 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 4.100 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 4.400 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 4.700 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 5.000 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 5.300 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 5.600 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 5.900 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 6.200 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 6.500 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 6.800 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 7.100 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 7.400 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 7.700 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 8.000 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 8.300 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 8.600 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 64 8.900 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 9.200 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 9.500 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 9.800 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 10.100 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 10.400 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 24.000 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 96.000 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 720.000 1.1602E+01 5.1561E-01 1.2963E+00 5.7610E-02 1.1446E+02 3.6174E+00 Worst Two-Hour Doses Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 0.0 1.5626E-01 1.1602E+01 5.1561E-01

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 65 Attachment B - RADTRAD Nuclide Inventory File JFHA_source_00.nif Nuclide Inventory Name:

J.A. Fitz Patrick FHA Core Inventory - DF =

200, PF = 1.82 Power Level:

0.1000E+01 Nuclides:

60 Nuclide 001:

Co-58 7

0.6117120000E+07 0.5800E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 002:

Co-60 7

0.1663401096E+09 0.6000E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 003:

Kr-83m 1

0.6588000000E+04 0.8300E+02 3.8900E+03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 004:

Kr-85 1

0.3382974720E+09 0.8500E+02 1.0520E+03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 005:

Kr-85m 1

0.1612800000E+05 0.8500E+02 8.6700E+03 Kr-85 0.2100E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 006:

Kr-87 1

0.4578000000E+04 0.8700E+02 1.7400E+04 Rb-87 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 007:

Kr-88 1

0.1022400000E+05 0.8800E+02 2.3600E+04 Rb-88 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 008:

Rb-86 3

0.1612224000E+07 0.8600E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 009:

Sr-89 5

0.4363200000E+07 0.8900E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 010:

Sr-90 5

0.9189573120E+09 0.9000E+02 0.0000E+00 Y-90 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 011:

Sr-91 5

0.3420000000E+05 0.9100E+02 0.0000E+00 Y-91m 0.5800E+00 Y-91 0.4200E+00 none 0.0000E+00 Nuclide 012:

Sr-92 5

0.9756000000E+04 0.9200E+02 0.0000E+00 Y-92 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 013:

Y-90 9

0.2304000000E+06 0.9000E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 014:

Y-91 9

0.5055264000E+07 0.9100E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 015:

Y-92 9

0.1274400000E+05 0.9200E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 016:

Y-93 9

0.3636000000E+05 0.9300E+02 0.0000E+00 Zr-93 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 017:

Zr-95 9

0.5527872000E+07 0.9500E+02 0.0000E+00 Nb-95m 0.7000E-02 Nb-95 0.9900E+00 none 0.0000E+00 Nuclide 018:

Zr-97 9

0.6084000000E+05 0.9700E+02 0.0000E+00 Nb-97m 0.9500E+00 Nb-97 0.5300E-01 none 0.0000E+00 Nuclide 019:

Nb-95

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 66 9

0.3036960000E+07 0.9500E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 020:

Mo-99 7

0.2376000000E+06 0.9900E+02 0.0000E+00 Tc-99m 0.8800E+00 Tc-99 0.1200E+00 none 0.0000E+00 Nuclide 021:

Tc-99m 7

0.2167200000E+05 0.9900E+02 0.0000E+00 Tc-99 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 022:

Ru-103 7

0.3393792000E+07 0.1030E+03 0.0000E+00 Rh-103m 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 023:

Ru-105 7

0.1598400000E+05 0.1050E+03 0.0000E+00 Rh-105 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 024:

Ru-106 7

0.3181248000E+08 0.1060E+03 0.0000E+00 Rh-106 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 025:

Rh-105 7

0.1272960000E+06 0.1050E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 026:

Sb-127 4

0.3326400000E+06 0.1270E+03 0.0000E+00 Te-127m 0.1800E+00 Te-127 0.8200E+00 none 0.0000E+00 Nuclide 027:

Sb-129 4

0.1555200000E+05 0.1290E+03 0.0000E+00 Te-129m 0.2200E+00 Te-129 0.7700E+00 none 0.0000E+00 Nuclide 028:

Te-127 4

0.3366000000E+05 0.1270E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 029:

Te-127m 4

0.9417600000E+07 0.1270E+03 0.0000E+00 Te-127 0.9800E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 030:

Te-129 4

0.4176000000E+04 0.1290E+03 0.0000E+00 I-129 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 031:

Br-83 2

0.8604040000E+04 0.830E+02 3.8800E+03 Kr-83m 1.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 032:

Br-84 2

0.1908000000E+04 0.8400E+02 7.3400E+03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 033:

I-130 2

0.4449600000E+05 0.1300E+03 7.0700E+02 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 034:

I-131 2

0.6946560000E+06 0.1310E+03 4.3360E+04 Xe-131m 0.1100E-01 none 0.0000E+00 none 0.0000E+00 Nuclide 035:

I-132 2

0.8280000000E+04 0.1320E+03 3.9600E+04 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 036:

I-133 2

0.7488000000E+05 0.1330E+03 5.6400E+04 Xe-133m 0.2900E-01 Xe-133 0.9700E+00 none 0.0000E+00 Nuclide 037:

I-134 2

0.3156000000E+04 0.1340E+03 6.4300E+04 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 038:

I-135 2

0.2379600000E+05 0.1350E+03

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 67 5.3300E+04 Xe-135m 0.1500E+00 Xe-135 0.8500E+00 none 0.0000E+00 Nuclide 039:

Xe-131m 1

0.1028160000E+07 0.1310E+03 3.8000E+02 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 040:

Xe-133 1

0.4531680000E+06 0.1330E+03 5.6300E+04 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 041:

Xe-133m 1

0.1890432000E+06 0.1330E+03 1.730E+03 Xe-133 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 042:

Xe-135 1

0.3272400000E+05 0.1350E+03 2.3100E+04 Cs-135 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 043:

Xe-135m 1

0.9174000000E+03 0.1350E+03 1.180E+04 Xe-135 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 044:

Xe-138 1

0.8502000000E+03 0.1380E+03 4.9900E+04 Cs-138 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 045:

Cs-134 3

0.6507177120E+08 0.1340E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 046:

Cs-136 3

0.1131840000E+07 0.1360E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 047:

Cs-137 3

0.9467280000E+09 0.1370E+03 0.0000E+00 Ba-137m 0.9500E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 048:

Ba-139 6

0.4962000000E+04 0.1390E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 049:

Ba-140 6

0.1100736000E+07 0.1400E+03 0.0000E+00 La-140 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 050:

La-140 9

0.1449792000E+06 0.1400E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 051:

La-141 9

0.1414800000E+05 0.1410E+03 0.0000E+00 Ce-141 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 052:

La-142 9

0.5550000000E+04 0.1420E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 053:

Ce-141 8

0.2808086400E+07 0.1410E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 054:

Ce-143 8

0.1188000000E+06 0.1430E+03 0.0000E+00 Pr-143 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 055:

Ce-144 8

0.2456352000E+08 0.1440E+03 0.0000E+00 Pr-144m 0.1800E-01 Pr-144 0.9800E+00 none 0.0000E+00 Nuclide 056:

Pr-143 9

0.1171584000E+07 0.1430E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 057:

Nd-147 9

0.9486720000E+06 0.1470E+03 0.0000E+00 Pm-147 0.1000E+01 none 0.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 68 none 0.0000E+00 Nuclide 058:

Np-239 8

0.2034720000E+06 0.2390E+03 0.0000E+00 Pu-239 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 059:

Pu-241 8

0.4544294400E+09 0.2410E+03 0.0000E+00 U-237 0.2400E-04 Am-241 0.1000E+01 none 0.0000E+00 Nuclide 060:

Cm-242 9

0.1406592000E+08 0.2420E+03 0.0000E+00 Pu-238 0.1000E+01 none 0.0000E+00 none 0.0000E+00 End of Nuclear Inventory File

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 69 JFHA_source_24.nif Nuclide Inventory Name:

J.A. Fitz Patrick FHA Core Inventory - DF = 200, PF = 1.82 Power Level:

0.1000E+01 Nuclides:

60 Nuclide 001:

Co-58 7

0.6117120000E+07 0.5800E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 002:

Co-60 7

0.1663401096E+09 0.6000E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 003:

Kr-83m 1

0.6588000000E+04 0.8300E+02 1.5800E+01 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 004:

Kr-85 1

0.3382974720E+09 0.8500E+02 1.0520E+03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 005:

Kr-85m 1

0.1612800000E+05 0.8500E+02 2.1400E+02 Kr-85 0.2100E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 006:

Kr-87 1

0.4578000000E+04 0.8700E+02 3.6800E-02 Rb-87 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 007:

Kr-88 1

0.1022400000E+05 0.8800E+02 6.7400E+01 Rb-88 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 008:

Rb-86 3

0.1612224000E+07 0.8600E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 009:

Sr-89 5

0.4363200000E+07 0.8900E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 010:

Sr-90 5

0.9189573120E+09 0.9000E+02 0.0000E+00 Y-90 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 011:

Sr-91 5

0.3420000000E+05 0.9100E+02 0.0000E+00 Y-91m 0.5800E+00 Y-91 0.4200E+00 none 0.0000E+00 Nuclide 012:

Sr-92 5

0.9756000000E+04 0.9200E+02 0.0000E+00 Y-92 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 013:

Y-90 9

0.2304000000E+06 0.9000E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 014:

Y-91 9

0.5055264000E+07 0.9100E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 015:

Y-92 9

0.1274400000E+05 0.9200E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 016:

Y-93 9

0.3636000000E+05 0.9300E+02 0.0000E+00 Zr-93 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 017:

Zr-95 9

0.5527872000E+07 0.9500E+02 0.0000E+00 Nb-95m 0.7000E-02 Nb-95 0.9900E+00 none 0.0000E+00 Nuclide 018:

Zr-97 9

0.6084000000E+05 0.9700E+02 0.0000E+00 Nb-97m 0.9500E+00 Nb-97 0.5300E-01 none 0.0000E+00 Nuclide 019:

Nb-95 9

0.3036960000E+07 0.9500E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 020:

Mo-99 7

0.2376000000E+06 0.9900E+02 0.0000E+00 Tc-99m 0.8800E+00 Tc-99 0.1200E+00 none 0.0000E+00 Nuclide 021:

Tc-99m 7

0.2167200000E+05 0.9900E+02

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 70 0.0000E+00 Tc-99 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 022:

Ru-103 7

0.3393792000E+07 0.1030E+03 0.0000E+00 Rh-103m 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 023:

Ru-105 7

0.1598400000E+05 0.1050E+03 0.0000E+00 Rh-105 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 024:

Ru-106 7

0.3181248000E+08 0.1060E+03 0.0000E+00 Rh-106 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 025:

Rh-105 7

0.1272960000E+06 0.1050E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 026:

Sb-127 4

0.3326400000E+06 0.1270E+03 0.0000E+00 Te-127m 0.1800E+00 Te-127 0.8200E+00 none 0.0000E+00 Nuclide 027:

Sb-129 4

0.1555200000E+05 0.1290E+03 0.0000E+00 Te-129m 0.2200E+00 Te-129 0.7700E+00 none 0.0000E+00 Nuclide 028:

Te-127 4

0.3366000000E+05 0.1270E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 029:

Te-127m 4

0.9417600000E+07 0.1270E+03 0.0000E+00 Te-127 0.9800E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 030:

Te-129 4

0.4176000000E+04 0.1290E+03 0.0000E+00 I-129 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 031:

Br-83 2

0.8604040000E+04 0.830E+02 4.1200E+00 Kr-83m 1.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 032:

Br-84 2

0.1908000000E+04 0.8400E+02 1.9000E-10 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 033:

I-130 2

0.4449600000E+05 0.1300E+03 1.8500E+02 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 034:

I-131 2

0.6946560000E+06 0.1310E+03 4.0480E+04 Xe-131m 0.1100E-01 none 0.0000E+00 none 0.0000E+00 Nuclide 035:

I-132 2

0.8280000000E+04 0.1320E+03 3.2200E+04 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 036:

I-133 2

0.7488000000E+05 0.1330E+03 2.6100E+04 Xe-133m 0.2900E-01 Xe-133 0.9700E+00 none 0.0000E+00 Nuclide 037:

I-134 2

0.3156000000E+04 0.1340E+03 1.5600E-03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 038:

I-135 2

0.2379600000E+05 0.1350E+03 4.2400E+04 Xe-135m 0.1500E+00 Xe-135 0.8500E+00 none 0.0000E+00 Nuclide 039:

Xe-131m 1

0.1028160000E+07 0.1310E+03 3.7500E+02 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 040:

Xe-133 1

0.4531680000E+06 0.1330E+03 5.4300E+04 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 041:

Xe-133m 1

0.1890432000E+06 0.1330E+03 1.550E+03 Xe-133 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 042:

Xe-135 1

0.3272400000E+05 0.1350E+03 1.5000E+04 Cs-135 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 043:

Xe-135m

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 71 1

0.9174000000E+03 0.1350E+03 6.920E+02 Xe-135 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 044:

Xe-138 1

0.8502000000E+03 0.1380E+03 8.1900E-27 Cs-138 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 045:

Cs-134 3

0.6507177120E+08 0.1340E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 046:

Cs-136 3

0.1131840000E+07 0.1360E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 047:

Cs-137 3

0.9467280000E+09 0.1370E+03 0.0000E+00 Ba-137m 0.9500E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 048:

Ba-139 6

0.4962000000E+04 0.1390E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 049:

Ba-140 6

0.1100736000E+07 0.1400E+03 0.0000E+00 La-140 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 050:

La-140 9

0.1449792000E+06 0.1400E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 051:

La-141 9

0.1414800000E+05 0.1410E+03 0.0000E+00 Ce-141 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 052:

La-142 9

0.5550000000E+04 0.1420E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 053:

Ce-141 8

0.2808086400E+07 0.1410E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 054:

Ce-143 8

0.1188000000E+06 0.1430E+03 0.0000E+00 Pr-143 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 055:

Ce-144 8

0.2456352000E+08 0.1440E+03 0.0000E+00 Pr-144m 0.1800E-01 Pr-144 0.9800E+00 none 0.0000E+00 Nuclide 056:

Pr-143 9

0.1171584000E+07 0.1430E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 057:

Nd-147 9

0.9486720000E+06 0.1470E+03 0.0000E+00 Pm-147 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 058:

Np-239 8

0.2034720000E+06 0.2390E+03 0.0000E+00 Pu-239 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 059:

Pu-241 8

0.4544294400E+09 0.2410E+03 0.0000E+00 U-237 0.2400E-04 Am-241 0.1000E+01 none 0.0000E+00 Nuclide 060:

Cm-242 9

0.1406592000E+08 0.2420E+03 0.0000E+00 Pu-238 0.1000E+01 none 0.0000E+00 none 0.0000E+00 End of Nuclear Inventory File

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 72 JFHA_source_96.nif Nuclide Inventory Name:

J.A. Fitz Patrick FHA Core Inventory - DF = 200, PF = 1.82 Power Level:

0.1000E+01 Nuclides:

60 Nuclide 001:

Co-58 7

0.6117120000E+07 0.5800E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 002:

Co-60 7

0.1663401096E+09 0.6000E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 003:

Kr-83m 1

0.6588000000E+04 0.8300E+02 1.8000E-08 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 004:

Kr-85 1

0.3382974720E+09 0.8500E+02 1.0520E+03 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 005:

Kr-85m 1

0.1612800000E+05 0.8500E+02 3.1100E-03 Kr-85 0.2100E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 006:

Kr-87 1

0.4578000000E+04 0.8700E+02 3.3600E-19 Rb-87 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 007:

Kr-88 1

0.1022400000E+05 0.8800E+02 1.5700E-06 Rb-88 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 008:

Rb-86 3

0.1612224000E+07 0.8600E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 009:

Sr-89 5

0.4363200000E+07 0.8900E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 010:

Sr-90 5

0.9189573120E+09 0.9000E+02 0.0000E+00 Y-90 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 011:

Sr-91 5

0.3420000000E+05 0.9100E+02 0.0000E+00 Y-91m 0.5800E+00 Y-91 0.4200E+00 none 0.0000E+00 Nuclide 012:

Sr-92 5

0.9756000000E+04 0.9200E+02 0.0000E+00 Y-92 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 013:

Y-90 9

0.2304000000E+06 0.9000E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 014:

Y-91 9

0.5055264000E+07 0.9100E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 015:

Y-92 9

0.1274400000E+05 0.9200E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 016:

Y-93 9

0.3636000000E+05 0.9300E+02 0.0000E+00 Zr-93 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 017:

Zr-95 9

0.5527872000E+07 0.9500E+02 0.0000E+00 Nb-95m 0.7000E-02 Nb-95 0.9900E+00 none 0.0000E+00 Nuclide 018:

Zr-97 9

0.6084000000E+05 0.9700E+02 0.0000E+00 Nb-97m 0.9500E+00 Nb-97 0.5300E-01 none 0.0000E+00 Nuclide 019:

Nb-95 9

0.3036960000E+07 0.9500E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 020:

Mo-99 7

0.2376000000E+06 0.9900E+02 0.0000E+00 Tc-99m 0.8800E+00 Tc-99 0.1200E+00 none 0.0000E+00 Nuclide 021:

Tc-99m 7

0.2167200000E+05 0.9900E+02

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 73 0.0000E+00 Tc-99 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 022:

Ru-103 7

0.3393792000E+07 0.1030E+03 0.0000E+00 Rh-103m 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 023:

Ru-105 7

0.1598400000E+05 0.1050E+03 0.0000E+00 Rh-105 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 024:

Ru-106 7

0.3181248000E+08 0.1060E+03 0.0000E+00 Rh-106 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 025:

Rh-105 7

0.1272960000E+06 0.1050E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 026:

Sb-127 4

0.3326400000E+06 0.1270E+03 0.0000E+00 Te-127m 0.1800E+00 Te-127 0.8200E+00 none 0.0000E+00 Nuclide 027:

Sb-129 4

0.1555200000E+05 0.1290E+03 0.0000E+00 Te-129m 0.2200E+00 Te-129 0.7700E+00 none 0.0000E+00 Nuclide 028:

Te-127 4

0.3366000000E+05 0.1270E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 029:

Te-127m 4

0.9417600000E+07 0.1270E+03 0.0000E+00 Te-127 0.9800E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 030:

Te-129 4

0.4176000000E+04 0.1290E+03 0.0000E+00 I-129 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 031:

Br-83 2

0.8604040000E+04 0.830E+02 3.8400E-09 Kr-83m 1.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 032:

Br-84 2

0.1908000000E+04 0.8400E+02 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 033:

I-130 2

0.4449600000E+05 0.1300E+03 3.2700E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 034:

I-131 2

0.6946560000E+06 0.1310E+03 3.1840E+04 Xe-131m 0.1100E-01 none 0.0000E+00 none 0.0000E+00 Nuclide 035:

I-132 2

0.8280000000E+04 0.1320E+03 1.7000E+04 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 036:

I-133 2

0.7488000000E+05 0.1330E+03 2.3700E+03 Xe-133m 0.2900E-01 Xe-133 0.9700E+00 none 0.0000E+00 Nuclide 037:

I-134 2

0.3156000000E+04 0.1340E+03 2.9700E-28 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 038:

I-135 2

0.2379600000E+05 0.1350E+03 2.1300E+00 Xe-135m 0.1500E+00 Xe-135 0.8500E+00 none 0.0000E+00 Nuclide 039:

Xe-131m 1

0.1028160000E+07 0.1310E+03 3.5400E+02 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 040:

Xe-133 1

0.4531680000E+06 0.1330E+03 3.9800E+04 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 041:

Xe-133m 1

0.1890432000E+06 0.1330E+03 7.4500E+02 Xe-133 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 042:

Xe-135 1

0.3272400000E+05 0.1350E+03 1.0500E+02 Cs-135 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 043:

Xe-135m

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 74 1

0.9174000000E+03 0.1350E+03 3.4800E-01 Xe-135 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 044:

Xe-138 1

0.8502000000E+03 0.1380E+03 0.0000E+00 Cs-138 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 045:

Cs-134 3

0.6507177120E+08 0.1340E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 046:

Cs-136 3

0.1131840000E+07 0.1360E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 047:

Cs-137 3

0.9467280000E+09 0.1370E+03 0.0000E+00 Ba-137m 0.9500E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 048:

Ba-139 6

0.4962000000E+04 0.1390E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 049:

Ba-140 6

0.1100736000E+07 0.1400E+03 0.0000E+00 La-140 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 050:

La-140 9

0.1449792000E+06 0.1400E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 051:

La-141 9

0.1414800000E+05 0.1410E+03 0.0000E+00 Ce-141 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 052:

La-142 9

0.5550000000E+04 0.1420E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 053:

Ce-141 8

0.2808086400E+07 0.1410E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 054:

Ce-143 8

0.1188000000E+06 0.1430E+03 0.0000E+00 Pr-143 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 055:

Ce-144 8

0.2456352000E+08 0.1440E+03 0.0000E+00 Pr-144m 0.1800E-01 Pr-144 0.9800E+00 none 0.0000E+00 Nuclide 056:

Pr-143 9

0.1171584000E+07 0.1430E+03 0.0000E+00 none 0.0000E+00 none 0.0000E+00 none 0.0000E+00 Nuclide 057:

Nd-147 9

0.9486720000E+06 0.1470E+03 0.0000E+00 Pm-147 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 058:

Np-239 8

0.2034720000E+06 0.2390E+03 0.0000E+00 Pu-239 0.1000E+01 none 0.0000E+00 none 0.0000E+00 Nuclide 059:

Pu-241 8

0.4544294400E+09 0.2410E+03 0.0000E+00 U-237 0.2400E-04 Am-241 0.1000E+01 none 0.0000E+00 Nuclide 060:

Cm-242 9

0.1406592000E+08 0.2420E+03 0.0000E+00 Pu-238 0.1000E+01 none 0.0000E+00 none 0.0000E+00 End of Nuclear Inventory File

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 75 Attachment C - RADTRAD Release Fraction and Timing File jafha_rft_with_DF.rft Release Fraction and Timing Name:

RELEASE_NAME = RG-1.183, Tables 3 Section 3.2 Duration (h):

3.6000E-03 0.0000E+00 0.0000E+00 0.0000E+00 Noble Gases:

5.0000E-02 0.0000E+00 0.0000E+00 0.0000E+00 Iodine:

2.5000E-04 0.0000E+00 0.0000E+00 0.0000E+00 Cesium:

1.2000E-01 0.0000E+00 0.0000E+00 0.0000E+00 Tellurium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Strontium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Barium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Ruthenium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Cerium:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Lanthanum:

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Non-Radioactive Aerosols (kg):

0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 End of Release File

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 76 Attachment D - RADTRAD FG 11 & 12 JAFHA_FG11&12.inp JAFHA_FGR11&12 added 8 nuclides; deleted Te129m,Te131m,Te132,Cm244,AM-242,Pu238-240 2/2001 Implicit daughter halflives (m) less than 90 and less than 0.100 of parent 9 ORGANS DEFINED IN THIS FILE:

GONADS BREAST LUNGS RED MARR BONE SUR THYROID REMAINDER EFFECTIVE SKIN(FGR) 60 NUCLIDES DEFINED IN THIS FILE:

Co-58 Y Co-60 Y Kr-83m data entered by Gopal J. Patel NUCORE/10/08/2001 Kr-85 Kr-85m Kr-87 Kr-88 Rb-86 D Sr-89 Y Sr-90 Y Sr-91 Y Including:Y-91m Sr-92 Y Y-90 Y Y-91 Y Y-92 Y Y-93 Y Zr-95 D Zr-97 Y Including:Nb-97m, Including:Nb-97 Nb-95 Y Mo-99 Y Tc-99m D Ru-103 Y Including:Rh-103m Ru-105 Y Ru-106 Y Including:Rh-106 Rh-105 Y Sb-127 W Sb-129 W Te-127 W Te-127m W Te-129 W Br-83 D data entered by Gopal J. Patel NUCORE/01/23/2002 Br-84 D data entered by Gopal J. Patel NUCORE/01/23/2002 I-130 D data entered by Gopal J. Patel NUCORE/01/23/2002 I-131 D I-132 D I-133 D I-134 D I-135 D Including:Xe-135m Xe-131m data entered by Gopal J. Patel NUCORE/10/08/2001 Xe-133 Xe-133m data entered by Gopal J. Patel NUCORE/10/08/2001 Xe-135 Xe-135m data entered by Gopal J. Patel NUCORE/10/08/2001 Xe-138 data entered by Gopal J. Patel NUCORE/10/08/2001 Cs-134 D Cs-136 D

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 77 Cs-137 D Including:Ba-137m Ba-139 D Ba-140 D La-140 W La-141 D La-142 D Ce-141 Y Ce-143 Y Ce-144 Y Including:Pr-144m, Including:Pr-144 Pr-143 Y Nd-147 Y Np-239 W Pu-241 Y Cm-242 W CLOUDSHINE GROUND GROUND GROUND INHALED INHALED INGESTION SHINE 8HR SHINE 7DAY SHINE RATE ACUTE CHRONIC Co-58 GONADS 4.660E-14 2.867E-11 5.828E-10 9.970E-16-1.000E+00 6.170E-10 1.040E-09 BREAST 5.300E-14 2.737E-11 5.565E-10 9.520E-16-1.000E+00 9.370E-10 1.790E-10 LUNGS 4.640E-14 2.617E-11 5.319E-10 9.100E-16-1.000E+00 1.600E-08 8.530E-11 RED MARR 4.530E-14 2.671E-11 5.430E-10 9.290E-16-1.000E+00 9.230E-10 2.600E-10 BONE SUR 7.410E-14 3.795E-11 7.716E-10 1.320E-15-1.000E+00 6.930E-10 1.250E-10 THYROID 4.770E-14 2.720E-11 5.530E-10 9.460E-16-1.000E+00 8.720E-10 6.310E-11 REMAINDER 4.440E-14 2.585E-11 5.255E-10 8.990E-16-1.000E+00 1.890E-09 1.580E-09 EFFECTIVE 4.760E-14 2.732E-11 5.553E-10 9.500E-16-1.000E+00 2.940E-09 8.090E-10 SKIN(FGR) 5.580E-14 3.278E-11 6.664E-10 1.140E-15-1.000E+00 0.000E+00 0.000E+00 Co-60 GONADS 1.230E-13 7.056E-11 1.480E-09 2.450E-15-1.000E+00 4.760E-09 3.190E-09 BREAST 1.390E-13 6.739E-11 1.413E-09 2.340E-15-1.000E+00 1.840E-08 1.100E-09 LUNGS 1.240E-13 6.537E-11 1.371E-09 2.270E-15-1.000E+00 3.450E-07 8.770E-10 RED MARR 1.230E-13 6.710E-11 1.407E-09 2.330E-15-1.000E+00 1.720E-08 1.320E-09 BONE SUR 1.780E-13 8.956E-11 1.879E-09 3.110E-15-1.000E+00 1.350E-08 9.390E-10 THYROID 1.270E-13 6.480E-11 1.359E-09 2.250E-15-1.000E+00 1.620E-08 7.880E-10 REMAINDER 1.200E-13 6.508E-11 1.365E-09 2.260E-15-1.000E+00 3.600E-08 4.970E-09 EFFECTIVE 1.260E-13 6.768E-11 1.419E-09 2.350E-15-1.000E+00 5.910E-08 2.770E-09 SKIN(FGR) 1.450E-13 7.948E-11 1.667E-09 2.760E-15-1.000E+00 0.000E+00 0.000E+00 Kr-83m GONADS 1.710E-18 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 BREAST 5.050E-18 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.640E-19 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 RED MARR 3.830E-19 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 BONE SUR 2.250E-18 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 THYROID 6.430E-19 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 REMAINDER 5.300E-19 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.500E-18 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 3.560E-17 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 Kr-85 GONADS 1.170E-16 8.121E-14 1.704E-12 2.820E-18-1.000E+00 0.000E+00 0.000E+00 BREAST 1.340E-16 7.891E-14 1.656E-12 2.740E-18-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.140E-16 7.056E-14 1.481E-12 2.450E-18-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.090E-16 6.998E-14 1.469E-12 2.430E-18-1.000E+00 0.000E+00 0.000E+00 BONE SUR 2.200E-16 1.287E-13 2.702E-12 4.470E-18-1.000E+00 0.000E+00 0.000E+00 THYROID 1.180E-16 7.459E-14 1.565E-12 2.590E-18-1.000E+00 0.000E+00 0.000E+00 REMAINDER 1.090E-16 6.941E-14 1.457E-12 2.410E-18-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.190E-16 7.603E-14 1.596E-12 2.640E-18-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 1.320E-14 2.304E-11 4.835E-10 8.000E-16-1.000E+00 0.000E+00 0.000E+00 Kr-85m GONADS 7.310E-15 2.594E-12 3.653E-12 1.570E-16-1.000E+00 0.000E+00 0.000E+00 BREAST 8.410E-15 2.527E-12 3.560E-12 1.530E-16-1.000E+00 0.000E+00 0.000E+00 LUNGS 7.040E-15 2.379E-12 3.351E-12 1.440E-16-1.000E+00 0.000E+00 0.000E+00 RED MARR 6.430E-15 2.346E-12 3.304E-12 1.420E-16-1.000E+00 0.000E+00 0.000E+00 BONE SUR 1.880E-14 5.286E-12 7.446E-12 3.200E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 7.330E-15 2.395E-12 3.374E-12 1.450E-16-1.000E+00 0.000E+00 0.000E+00 REMAINDER 6.640E-15 2.313E-12 3.257E-12 1.400E-16-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 7.480E-15 2.511E-12 3.537E-12 1.520E-16-1.000E+00 0.000E+00 0.000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 78 SKIN(FGR) 2.240E-14 2.247E-11 3.164E-11 1.360E-15-1.000E+00 0.000E+00 0.000E+00 Kr-87 GONADS 4.000E-14 4.962E-12 5.026E-12 7.610E-16-1.000E+00 0.000E+00 0.000E+00 BREAST 4.500E-14 4.740E-12 4.802E-12 7.270E-16-1.000E+00 0.000E+00 0.000E+00 LUNGS 4.040E-14 4.603E-12 4.663E-12 7.060E-16-1.000E+00 0.000E+00 0.000E+00 RED MARR 4.000E-14 4.708E-12 4.769E-12 7.220E-16-1.000E+00 0.000E+00 0.000E+00 BONE SUR 6.020E-14 6.514E-12 6.598E-12 9.990E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 4.130E-14 4.473E-12 4.531E-12 6.860E-16-1.000E+00 0.000E+00 0.000E+00 REMAINDER 3.910E-14 4.590E-12 4.650E-12 7.040E-16-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 4.120E-14 4.773E-12 4.835E-12 7.320E-16-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 1.370E-13 8.802E-11 8.916E-11 1.350E-14-1.000E+00 0.000E+00 0.000E+00 Kr-88 GONADS 9.900E-14 2.278E-11 2.655E-11 1.800E-15-1.000E+00 0.000E+00 0.000E+00 BREAST 1.110E-13 2.177E-11 2.537E-11 1.720E-15-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.010E-13 2.139E-11 2.493E-11 1.690E-15-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.000E-13 2.190E-11 2.552E-11 1.730E-15-1.000E+00 0.000E+00 0.000E+00 BONE SUR 1.390E-13 2.886E-11 3.363E-11 2.280E-15-1.000E+00 0.000E+00 0.000E+00 THYROID 1.030E-13 2.012E-11 2.345E-11 1.590E-15-1.000E+00 0.000E+00 0.000E+00 REMAINDER 9.790E-14 2.139E-11 2.493E-11 1.690E-15-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.020E-13 2.202E-11 2.567E-11 1.740E-15-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 1.350E-13 5.607E-11 6.534E-11 4.430E-15-1.000E+00 0.000E+00 0.000E+00 Rb-86 GONADS 4.710E-15 2.788E-12 5.187E-11 9.740E-17-1.000E+00 1.340E-09 2.150E-09 BREAST 5.340E-15 2.662E-12 4.953E-11 9.300E-17-1.000E+00 1.330E-09 2.140E-09 LUNGS 4.710E-15 2.553E-12 4.750E-11 8.920E-17-1.000E+00 3.300E-09 2.140E-09 RED MARR 4.640E-15 2.619E-12 4.873E-11 9.150E-17-1.000E+00 2.320E-09 3.720E-09 BONE SUR 7.050E-15 3.635E-12 6.764E-11 1.270E-16-1.000E+00 4.270E-09 6.860E-09 THYROID 4.840E-15 2.599E-12 4.836E-11 9.080E-17-1.000E+00 1.330E-09 2.140E-09 REMAINDER 4.520E-15 2.542E-12 4.729E-11 8.880E-17-1.000E+00 1.380E-09 2.330E-09 EFFECTIVE 4.810E-15 2.665E-12 4.958E-11 9.310E-17-1.000E+00 1.790E-09 2.530E-09 SKIN(FGR) 4.850E-14 2.210E-10 4.111E-09 7.720E-15-1.000E+00 0.000E+00 0.000E+00 Sr-89 GONADS 7.730E-17 7.155E-14 1.436E-12 2.490E-18-1.000E+00 7.950E-12 8.050E-12 BREAST 9.080E-17 7.212E-14 1.447E-12 2.510E-18-1.000E+00 7.960E-12 7.980E-12 LUNGS 7.080E-17 5.689E-14 1.142E-12 1.980E-18-1.000E+00 8.350E-08 7.970E-12 RED MARR 6.390E-17 5.345E-14 1.073E-12 1.860E-18-1.000E+00 1.070E-10 1.080E-10 BONE SUR 1.940E-16 1.560E-13 3.131E-12 5.430E-18-1.000E+00 1.590E-10 1.610E-10 THYROID 7.600E-17 6.063E-14 1.217E-12 2.110E-18-1.000E+00 7.960E-12 7.970E-12 REMAINDER 6.710E-17 5.603E-14 1.124E-12 1.950E-18-1.000E+00 3.970E-09 8.250E-09 EFFECTIVE 7.730E-17 6.523E-14 1.309E-12 2.270E-18-1.000E+00 1.120E-08 2.500E-09 SKIN(FGR) 3.690E-14 1.914E-10 3.841E-09 6.660E-15-1.000E+00 0.000E+00 0.000E+00 Sr-90 GONADS 7.780E-18 9.590E-15 2.014E-13 3.330E-19-1.000E+00 2.690E-10 5.040E-11 BREAST 9.490E-18 1.008E-14 2.116E-13 3.500E-19-1.000E+00 2.690E-10 5.040E-11 LUNGS 6.440E-18 6.307E-15 1.324E-13 2.190E-19-1.000E+00 2.860E-06 5.040E-11 RED MARR 5.440E-18 5.558E-15 1.167E-13 1.930E-19-1.000E+00 3.280E-08 6.450E-09 BONE SUR 2.280E-17 2.393E-14 5.025E-13 8.310E-19-1.000E+00 7.090E-08 1.390E-08 THYROID 7.330E-18 7.171E-15 1.506E-13 2.490E-19-1.000E+00 2.690E-10 5.040E-11 REMAINDER 6.110E-18 6.422E-15 1.348E-13 2.230E-19-1.000E+00 5.730E-09 6.700E-09 EFFECTIVE 7.530E-18 8.179E-15 1.717E-13 2.840E-19-1.000E+00 3.510E-07 3.230E-09 SKIN(FGR) 9.200E-15 4.032E-12 8.465E-11 1.400E-16-1.000E+00 0.000E+00 0.000E+00 Sr-91 GONADS 4.819E-14 2.155E-11 5.062E-11 1.026E-15-1.000E+00 5.669E-11 2.520E-10 BREAST 5.477E-14 2.059E-11 4.838E-11 9.806E-16-1.000E+00 1.775E-11 3.676E-11 LUNGS 4.803E-14 1.970E-11 4.626E-11 9.376E-16-1.000E+00 2.170E-09 1.055E-11 RED MARR 4.691E-14 2.011E-11 4.722E-11 9.570E-16-1.000E+00 2.275E-11 5.659E-11 BONE SUR 7.674E-14 2.852E-11 6.709E-11 1.360E-15-1.000E+00 1.306E-11 2.070E-11 THYROID 4.938E-14 2.035E-11 4.782E-11 9.693E-16-1.000E+00 9.930E-12 1.968E-12 REMAINDER 4.610E-14 1.948E-11 4.573E-11 9.268E-16-1.000E+00 5.802E-10 2.557E-09 EFFECTIVE 4.924E-14 2.057E-11 4.832E-11 9.793E-16-1.000E+00 4.547E-10 8.455E-10 SKIN(FGR) 9.938E-14 1.748E-10 3.987E-10 8.080E-15-1.000E+00 0.000E+00 0.000E+00 Sr-92 GONADS 6.610E-14 1.593E-11 1.830E-11 1.300E-15-1.000E+00 1.020E-11 8.180E-11 BREAST 7.480E-14 1.520E-11 1.745E-11 1.240E-15-1.000E+00 6.490E-12 1.700E-11 LUNGS 6.670E-14 1.483E-11 1.703E-11 1.210E-15-1.000E+00 1.050E-09 7.220E-12

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 79 RED MARR 6.620E-14 1.520E-11 1.745E-11 1.240E-15-1.000E+00 6.980E-12 2.290E-11 BONE SUR 9.490E-14 2.010E-11 2.308E-11 1.640E-15-1.000E+00 4.360E-12 8.490E-12 THYROID 6.820E-14 1.446E-11 1.661E-11 1.180E-15-1.000E+00 3.920E-12 1.300E-12 REMAINDER 6.450E-14 1.471E-11 1.689E-11 1.200E-15-1.000E+00 2.900E-10 1.720E-09 EFFECTIVE 6.790E-14 1.532E-11 1.759E-11 1.250E-15-1.000E+00 2.180E-10 5.430E-10 SKIN(FGR) 8.560E-14 2.280E-11 2.618E-11 1.860E-15-1.000E+00 0.000E+00 0.000E+00 Y-90 GONADS 1.890E-16 1.586E-13 1.601E-12 5.750E-18-1.000E+00 5.170E-13 1.430E-14 BREAST 2.200E-16 1.578E-13 1.593E-12 5.720E-18-1.000E+00 5.170E-13 1.270E-14 LUNGS 1.770E-16 1.313E-13 1.326E-12 4.760E-18-1.000E+00 9.310E-09 1.260E-14 RED MARR 1.620E-16 1.261E-13 1.273E-12 4.570E-18-1.000E+00 1.520E-11 3.700E-13 BONE SUR 4.440E-16 3.228E-13 3.259E-12 1.170E-17-1.000E+00 1.510E-11 3.670E-13 THYROID 1.870E-16 1.385E-13 1.398E-12 5.020E-18-1.000E+00 5.170E-13 1.260E-14 REMAINDER 1.680E-16 1.291E-13 1.303E-12 4.680E-18-1.000E+00 3.870E-09 9.680E-09 EFFECTIVE 1.900E-16 1.468E-13 1.482E-12 5.320E-18-1.000E+00 2.280E-09 2.910E-09 SKIN(FGR) 6.240E-14 2.897E-10 2.924E-09 1.050E-14-1.000E+00 0.000E+00 0.000E+00 Y-91 GONADS 2.560E-16 1.756E-13 3.546E-12 6.110E-18-1.000E+00 8.200E-12 3.540E-12 BREAST 2.930E-16 1.713E-13 3.459E-12 5.960E-18-1.000E+00 8.920E-12 5.540E-13 LUNGS 2.500E-16 1.526E-13 3.082E-12 5.310E-18-1.000E+00 9.870E-08 2.020E-13 RED MARR 2.410E-16 1.521E-13 3.070E-12 5.290E-18-1.000E+00 3.190E-10 6.590E-12 BONE SUR 4.560E-16 2.903E-13 5.862E-12 1.010E-17-1.000E+00 3.180E-10 6.130E-12 THYROID 2.600E-16 1.564E-13 3.157E-12 5.440E-18-1.000E+00 8.500E-12 1.290E-13 REMAINDER 2.390E-16 1.509E-13 3.047E-12 5.250E-18-1.000E+00 4.200E-09 8.570E-09 EFFECTIVE 2.600E-16 1.650E-13 3.332E-12 5.740E-18-1.000E+00 1.320E-08 2.570E-09 SKIN(FGR) 3.850E-14 1.989E-10 4.016E-09 6.920E-15-1.000E+00 0.000E+00 0.000E+00 Y-92 GONADS 1.270E-14 3.855E-12 4.872E-12 2.650E-16-1.000E+00 2.610E-12 1.960E-11 BREAST 1.440E-14 3.680E-12 4.652E-12 2.530E-16-1.000E+00 1.500E-12 3.550E-12 LUNGS 1.270E-14 3.535E-12 4.468E-12 2.430E-16-1.000E+00 1.240E-09 1.390E-12 RED MARR 1.250E-14 3.608E-12 4.560E-12 2.480E-16-1.000E+00 2.070E-12 4.910E-12 BONE SUR 1.950E-14 5.091E-12 6.435E-12 3.500E-16-1.000E+00 1.510E-12 1.750E-12 THYROID 1.300E-14 3.579E-12 4.523E-12 2.460E-16-1.000E+00 1.050E-12 1.770E-13 REMAINDER 1.220E-14 3.506E-12 4.431E-12 2.410E-16-1.000E+00 2.030E-10 1.700E-09 EFFECTIVE 1.300E-14 3.680E-12 4.652E-12 2.530E-16-1.000E+00 2.110E-10 5.150E-10 SKIN(FGR) 1.140E-13 2.022E-10 2.556E-10 1.390E-14-1.000E+00 0.000E+00 0.000E+00 Y-93 GONADS 4.670E-15 2.108E-12 4.989E-12 9.510E-17-1.000E+00 5.310E-12 2.200E-11 BREAST 5.300E-15 2.026E-12 4.794E-12 9.140E-17-1.000E+00 1.740E-12 3.130E-12 LUNGS 4.680E-15 1.937E-12 4.585E-12 8.740E-17-1.000E+00 2.520E-09 8.670E-13 RED MARR 4.580E-15 1.972E-12 4.669E-12 8.900E-17-1.000E+00 4.040E-12 4.930E-12 BONE SUR 7.580E-15 2.948E-12 6.977E-12 1.330E-16-1.000E+00 3.140E-12 1.730E-12 THYROID 4.790E-15 1.908E-12 4.516E-12 8.610E-17-1.000E+00 9.260E-13 1.260E-13 REMAINDER 4.510E-15 1.919E-12 4.543E-12 8.660E-17-1.000E+00 9.250E-10 4.090E-09 EFFECTIVE 4.800E-15 2.021E-12 4.784E-12 9.120E-17-1.000E+00 5.820E-10 1.230E-09 SKIN(FGR) 8.500E-14 2.726E-10 6.452E-10 1.230E-14-1.000E+00 0.000E+00 0.000E+00 Zr-95 GONADS 3.530E-14 2.182E-11 4.421E-10 7.590E-16-1.000E+00 1.880E-09 8.160E-10 BREAST 4.010E-14 2.084E-11 4.223E-10 7.250E-16-1.000E+00 1.910E-09 1.050E-10 LUNGS 3.510E-14 1.989E-11 4.030E-10 6.920E-16-1.000E+00 2.170E-09 2.340E-11 RED MARR 3.430E-14 2.030E-11 4.112E-10 7.060E-16-1.000E+00 1.300E-08 2.140E-10 BONE SUR 5.620E-14 2.875E-11 5.824E-10 1.000E-15-1.000E+00 1.030E-07 4.860E-10 THYROID 3.610E-14 2.076E-11 4.205E-10 7.220E-16-1.000E+00 1.440E-09 8.270E-12 REMAINDER 3.360E-14 1.963E-11 3.978E-10 6.830E-16-1.000E+00 2.280E-09 2.530E-09 EFFECTIVE 3.600E-14 2.078E-11 4.211E-10 7.230E-16-1.000E+00 6.390E-09 1.020E-09 SKIN(FGR) 4.500E-14 2.561E-11 5.190E-10 8.910E-16-1.000E+00 0.000E+00 0.000E+00 Zr-97 GONADS 4.331E-14 2.179E-11 7.799E-11 9.253E-16-1.000E+00 1.840E-10 6.228E-10 BREAST 4.928E-14 2.083E-11 7.455E-11 8.846E-16-1.000E+00 4.706E-11 8.137E-11 LUNGS 4.322E-14 1.992E-11 7.127E-11 8.456E-16-1.000E+00 4.108E-09 1.770E-11 RED MARR 4.224E-14 2.034E-11 7.279E-11 8.634E-16-1.000E+00 6.376E-11 1.302E-10 BONE SUR 6.897E-14 2.881E-11 1.031E-10 1.224E-15-1.000E+00 3.504E-11 4.558E-11 THYROID 4.443E-14 2.061E-11 7.377E-11 8.755E-16-1.000E+00 2.315E-11 2.671E-12 REMAINDER 4.139E-14 1.966E-11 7.035E-11 8.345E-16-1.000E+00 2.041E-09 6.990E-09 EFFECTIVE 4.432E-14 2.078E-11 7.438E-11 8.824E-16-1.000E+00 1.171E-09 2.283E-09

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 80 SKIN(FGR) 9.835E-14 2.281E-10 8.148E-10 9.587E-15-1.000E+00 0.000E+00 0.000E+00 Nb-95 GONADS 3.660E-14 2.253E-11 4.435E-10 7.850E-16-1.000E+00 4.320E-10 8.050E-10 BREAST 4.160E-14 2.150E-11 4.231E-10 7.490E-16-1.000E+00 4.070E-10 1.070E-10 LUNGS 3.650E-14 2.055E-11 4.045E-10 7.160E-16-1.000E+00 8.320E-09 2.740E-11 RED MARR 3.560E-14 2.101E-11 4.135E-10 7.320E-16-1.000E+00 4.420E-10 1.990E-10 BONE SUR 5.790E-14 2.957E-11 5.819E-10 1.030E-15-1.000E+00 5.130E-10 2.940E-10 THYROID 3.750E-14 2.144E-11 4.220E-10 7.470E-16-1.000E+00 3.580E-10 1.180E-11 REMAINDER 3.490E-14 2.032E-11 4.000E-10 7.080E-16-1.000E+00 1.070E-09 1.470E-09 EFFECTIVE 3.740E-14 2.147E-11 4.226E-10 7.480E-16-1.000E+00 1.570E-09 6.950E-10 SKIN(FGR) 4.300E-14 2.598E-11 5.112E-10 9.050E-16-1.000E+00 0.000E+00 0.000E+00 Mo-99 GONADS 7.130E-15 4.282E-12 4.403E-11 1.550E-16-1.000E+00 9.510E-11 2.180E-10 BREAST 8.130E-15 4.116E-12 4.233E-11 1.490E-16-1.000E+00 2.750E-11 3.430E-11 LUNGS 7.060E-15 3.867E-12 3.977E-11 1.400E-16-1.000E+00 4.290E-09 1.510E-11 RED MARR 6.820E-15 3.923E-12 4.034E-11 1.420E-16-1.000E+00 5.240E-11 8.320E-11 BONE SUR 1.240E-14 6.105E-12 6.278E-11 2.210E-16-1.000E+00 4.130E-11 6.320E-11 THYROID 7.270E-15 4.033E-12 4.147E-11 1.460E-16-1.000E+00 1.520E-11 1.030E-11 REMAINDER 6.740E-15 3.812E-12 3.920E-11 1.380E-16-1.000E+00 1.740E-09 4.280E-09 EFFECTIVE 7.280E-15 4.061E-12 4.176E-11 1.470E-16-1.000E+00 1.070E-09 1.360E-09 SKIN(FGR) 3.140E-14 1.039E-10 1.068E-09 3.760E-15-1.000E+00 0.000E+00 0.000E+00 Tc-99m GONADS 5.750E-15 2.334E-12 3.877E-12 1.240E-16-1.000E+00 2.770E-12 9.750E-12 BREAST 6.650E-15 2.258E-12 3.752E-12 1.200E-16-1.000E+00 2.150E-12 3.570E-12 LUNGS 5.490E-15 2.127E-12 3.533E-12 1.130E-16-1.000E+00 2.280E-11 3.140E-12 RED MARR 4.910E-15 2.070E-12 3.439E-12 1.100E-16-1.000E+00 3.360E-12 6.290E-12 BONE SUR 1.630E-14 5.383E-12 8.942E-12 2.860E-16-1.000E+00 2.620E-12 4.060E-12 THYROID 5.750E-15 2.145E-12 3.564E-12 1.140E-16-1.000E+00 5.010E-11 8.460E-11 REMAINDER 5.150E-15 2.070E-12 3.439E-12 1.100E-16-1.000E+00 1.020E-11 3.340E-11 EFFECTIVE 5.890E-15 2.277E-12 3.783E-12 1.210E-16-1.000E+00 8.800E-12 1.680E-11 SKIN(FGR) 7.140E-15 2.710E-12 4.502E-12 1.440E-16-1.000E+00 0.000E+00 0.000E+00 Ru-103 GONADS 2.191E-14 1.404E-11 2.783E-10 4.892E-16-1.000E+00 3.070E-10 5.720E-10 BREAST 2.512E-14 1.350E-11 2.677E-10 4.705E-16-1.000E+00 3.110E-10 1.200E-10 LUNGS 2.180E-14 1.273E-11 2.522E-10 4.432E-16-1.000E+00 1.561E-08 7.310E-11 RED MARR 2.100E-14 1.287E-11 2.551E-10 4.483E-16-1.000E+00 3.190E-10 1.660E-10 BONE SUR 3.892E-14 1.958E-11 3.882E-10 6.823E-16-1.000E+00 2.370E-10 9.631E-11 THYROID 2.241E-14 1.331E-11 2.639E-10 4.638E-16-1.000E+00 2.570E-10 6.250E-11 REMAINDER 2.080E-14 1.248E-11 2.472E-10 4.346E-16-1.000E+00 1.250E-09 2.110E-09 EFFECTIVE 2.251E-14 1.332E-11 2.641E-10 4.642E-16-1.000E+00 2.421E-09 8.271E-10 SKIN(FGR) 2.774E-14 1.785E-11 3.543E-10 6.229E-16-1.000E+00 0.000E+00 0.000E+00 Ru-105 GONADS 3.720E-14 1.327E-11 1.861E-11 8.070E-16-1.000E+00 1.590E-11 9.670E-11 BREAST 4.240E-14 1.271E-11 1.783E-11 7.730E-16-1.000E+00 6.610E-12 1.590E-11 LUNGS 3.700E-14 1.210E-11 1.697E-11 7.360E-16-1.000E+00 5.730E-10 6.210E-12 RED MARR 3.590E-14 1.230E-11 1.725E-11 7.480E-16-1.000E+00 7.700E-12 2.350E-11 BONE SUR 6.280E-14 1.809E-11 2.537E-11 1.100E-15-1.000E+00 4.620E-12 8.890E-12 THYROID 3.800E-14 1.260E-11 1.766E-11 7.660E-16-1.000E+00 4.150E-12 1.820E-12 REMAINDER 3.540E-14 1.189E-11 1.667E-11 7.230E-16-1.000E+00 1.610E-10 8.540E-10 EFFECTIVE 3.810E-14 1.265E-11 1.773E-11 7.690E-16-1.000E+00 1.230E-10 2.870E-10 SKIN(FGR) 6.730E-14 7.368E-11 1.033E-10 4.480E-15-1.000E+00 0.000E+00 0.000E+00 Ru-106 GONADS 1.010E-14 6.411E-12 1.340E-10 2.230E-16-1.000E+00 1.300E-09 1.640E-09 BREAST 1.160E-14 6.152E-12 1.286E-10 2.140E-16-1.000E+00 1.780E-09 1.440E-09 LUNGS 1.010E-14 5.836E-12 1.220E-10 2.030E-16-1.000E+00 1.040E-06 1.420E-09 RED MARR 9.750E-15 5.893E-12 1.232E-10 2.050E-16-1.000E+00 1.760E-09 1.460E-09 BONE SUR 1.720E-14 8.883E-12 1.856E-10 3.090E-16-1.000E+00 1.610E-09 1.430E-09 THYROID 1.030E-14 6.066E-12 1.268E-10 2.110E-16-1.000E+00 1.720E-09 1.410E-09 REMAINDER 9.630E-15 5.721E-12 1.196E-10 1.990E-16-1.000E+00 1.200E-08 2.110E-08 EFFECTIVE 1.040E-14 6.095E-12 1.274E-10 2.120E-16-1.000E+00 1.290E-07 7.400E-09 SKIN(FGR) 1.090E-13 4.082E-10 8.531E-09 1.420E-14-1.000E+00 0.000E+00 0.000E+00 Rh-105 GONADS 3.640E-15 2.127E-12 1.411E-11 7.980E-17-1.000E+00 2.110E-11 5.800E-11 BREAST 4.160E-15 2.063E-12 1.369E-11 7.740E-17-1.000E+00 5.610E-12 8.970E-12 LUNGS 3.570E-15 1.935E-12 1.284E-11 7.260E-17-1.000E+00 9.580E-10 3.860E-12

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 81 RED MARR 3.380E-15 1.946E-12 1.291E-11 7.300E-17-1.000E+00 7.770E-12 1.470E-11 BONE SUR 7.530E-15 3.332E-12 2.210E-11 1.250E-16-1.000E+00 4.460E-12 6.750E-12 THYROID 3.680E-15 1.983E-12 1.316E-11 7.440E-17-1.000E+00 2.880E-12 2.910E-12 REMAINDER 3.390E-15 1.885E-12 1.250E-11 7.070E-17-1.000E+00 4.530E-10 1.270E-09 EFFECTIVE 3.720E-15 2.031E-12 1.347E-11 7.620E-17-1.000E+00 2.580E-10 3.990E-10 SKIN(FGR) 1.070E-14 4.691E-12 3.112E-11 1.760E-16-1.000E+00 0.000E+00 0.000E+00 Sb-127 GONADS 3.260E-14 1.985E-11 2.441E-10 7.100E-16-1.000E+00 2.520E-10 6.140E-10 BREAST 3.720E-14 1.904E-11 2.341E-10 6.810E-16-1.000E+00 9.120E-11 7.600E-11 LUNGS 3.240E-14 1.809E-11 2.224E-10 6.470E-16-1.000E+00 6.940E-09 1.570E-11 RED MARR 3.140E-14 1.834E-11 2.255E-10 6.560E-16-1.000E+00 1.610E-10 1.330E-10 BONE SUR 5.520E-14 2.720E-11 3.345E-10 9.730E-16-1.000E+00 1.340E-10 5.240E-11 THYROID 3.330E-14 1.884E-11 2.317E-10 6.740E-16-1.000E+00 6.150E-11 4.640E-12 REMAINDER 3.090E-14 1.775E-11 2.183E-10 6.350E-16-1.000E+00 2.330E-09 5.870E-09 EFFECTIVE 3.330E-14 1.890E-11 2.324E-10 6.760E-16-1.000E+00 1.630E-09 1.950E-09 SKIN(FGR) 5.580E-14 7.967E-11 9.799E-10 2.850E-15-1.000E+00 0.000E+00 0.000E+00 Sb-129 GONADS 6.970E-14 2.336E-11 3.231E-11 1.440E-15-1.000E+00 2.150E-11 1.510E-10 BREAST 7.910E-14 2.222E-11 3.074E-11 1.370E-15-1.000E+00 1.280E-11 2.560E-11 LUNGS 6.980E-14 2.141E-11 2.962E-11 1.320E-15-1.000E+00 8.980E-10 9.390E-12 RED MARR 6.860E-14 2.190E-11 3.029E-11 1.350E-15-1.000E+00 1.700E-11 3.670E-11 BONE SUR 1.070E-13 3.033E-11 4.196E-11 1.870E-15-1.000E+00 1.460E-11 1.340E-11 THYROID 7.160E-14 2.174E-11 3.007E-11 1.340E-15-1.000E+00 9.720E-12 1.470E-12 REMAINDER 6.710E-14 2.125E-11 2.939E-11 1.310E-15-1.000E+00 1.870E-10 1.450E-09 EFFECTIVE 7.140E-14 2.238E-11 3.096E-11 1.380E-15-1.000E+00 1.740E-10 4.840E-10 SKIN(FGR) 1.050E-13 8.273E-11 1.144E-10 5.100E-15-1.000E+00 0.000E+00 0.000E+00 Te-127 GONADS 2.370E-16 1.191E-13 2.661E-13 5.480E-18-1.000E+00 2.020E-12 4.020E-12 BREAST 2.730E-16 1.158E-13 2.588E-13 5.330E-18-1.000E+00 1.880E-12 3.000E-12 LUNGS 2.320E-16 1.060E-13 2.370E-13 4.880E-18-1.000E+00 4.270E-10 2.890E-12 RED MARR 2.210E-16 1.058E-13 2.365E-13 4.870E-18-1.000E+00 4.090E-12 6.570E-12 BONE SUR 4.650E-16 1.862E-13 4.162E-13 8.570E-18-1.000E+00 4.090E-12 6.460E-12 THYROID 2.400E-16 1.106E-13 2.472E-13 5.090E-18-1.000E+00 1.840E-12 2.860E-12 REMAINDER 2.210E-16 1.036E-13 2.316E-13 4.770E-18-1.000E+00 1.110E-10 6.130E-10 EFFECTIVE 2.420E-16 1.125E-13 2.515E-13 5.180E-18-1.000E+00 8.600E-11 1.870E-10 SKIN(FGR) 1.140E-14 1.173E-11 2.622E-11 5.400E-16-1.000E+00 0.000E+00 0.000E+00 Te-127m GONADS 1.900E-16 4.689E-13 9.642E-12 1.630E-17-1.000E+00 1.100E-10 1.250E-10 BREAST 2.690E-16 5.150E-13 1.059E-11 1.790E-17-1.000E+00 1.100E-10 9.740E-11 LUNGS 7.620E-17 1.602E-13 3.295E-12 5.570E-18-1.000E+00 3.340E-08 9.620E-11 RED MARR 6.430E-17 1.249E-13 2.567E-12 4.340E-18-1.000E+00 5.360E-09 5.430E-09 BONE SUR 3.940E-16 9.005E-13 1.852E-11 3.130E-17-1.000E+00 2.040E-08 2.070E-08 THYROID 1.500E-16 2.779E-13 5.714E-12 9.660E-18-1.000E+00 9.660E-11 9.430E-11 REMAINDER 8.640E-17 1.999E-13 4.111E-12 6.950E-18-1.000E+00 1.660E-09 2.980E-09 EFFECTIVE 1.470E-16 3.251E-13 6.684E-12 1.130E-17-1.000E+00 5.810E-09 2.230E-09 SKIN(FGR) 8.490E-16 1.496E-12 3.076E-11 5.200E-17-1.000E+00 0.000E+00 0.000E+00 Te-129 GONADS 2.710E-15 3.889E-13 3.922E-13 6.510E-17-1.000E+00 5.050E-13 1.590E-12 BREAST 3.120E-15 3.800E-13 3.832E-13 6.360E-17-1.000E+00 5.390E-13 6.050E-13 LUNGS 2.640E-15 3.298E-13 3.326E-13 5.520E-17-1.000E+00 1.530E-10 4.910E-13 RED MARR 2.540E-15 3.298E-13 3.326E-13 5.520E-17-1.000E+00 6.190E-13 7.640E-13 BONE SUR 4.880E-15 5.753E-13 5.802E-13 9.630E-17-1.000E+00 6.220E-13 5.400E-13 THYROID 2.740E-15 3.525E-13 3.555E-13 5.900E-17-1.000E+00 5.090E-13 3.360E-13 REMAINDER 2.520E-15 3.262E-13 3.289E-13 5.460E-17-1.000E+00 7.280E-12 1.790E-10 EFFECTIVE 2.750E-15 3.590E-13 3.621E-13 6.010E-17-1.000E+00 2.090E-11 5.450E-11 SKIN(FGR) 3.570E-14 3.429E-11 3.458E-11 5.740E-15-1.000E+00 0.000E+00 0.000E+00 Br-83 GONADS 3.740E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 3.280E-12 7.350E-12 BREAST 4.290E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 3.290E-12 7.340E-12 LUNGS 3.690E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 1.500E-10 7.350E-12 RED MARR 3.540E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 3.300E-12 7.350E-12 BONE SUR 6.750E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 3.200E-12 7.330E-12 THYROID 3.800E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 3.290E-12 7.330E-12 REMAINDER 3.520E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 1.130E-11 6.540E-11 EFFECTIVE 3.820E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 2.330E-11 2.470E-11

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 82 SKIN(FGR) 1.850E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 Br-84 GONADS 9.160E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 2.840E-12 6.750E-12 BREAST 1.020E-13 0.000E+00 0.000E+00 0.000E+00-1.000E+00 3.310E-12 6.620E-12 LUNGS 9.270E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 1.560E-10 6.990E-12 RED MARR 9.260E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 3.270E-12 6.210E-12 BONE SUR 1.280E-13 0.000E+00 0.000E+00 0.000E+00-1.000E+00 2.990E-12 5.560E-12 THYROID 9.500E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 3.120E-12 5.200E-12 REMAINDER 8.990E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 1.870E-11 1.480E-10 EFFECTIVE 9.410E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 2.610E-11 4.910E-11 SKIN(FGR) 1.880E-13 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 I-130 GONADS 1.010E-13 0.000E+00 0.000E+00 0.000E+00-1.000E+00 2.810E-11 5.520E-11 BREAST 1.160E-13 0.000E+00 0.000E+00 0.000E+00-1.000E+00 4.870E-11 7.320E-11 LUNGS 1.010E-13 0.000E+00 0.000E+00 0.000E+00-1.000E+00 6.030E-10 7.180E-11 RED MARR 9.820E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 4.550E-11 6.740E-11 BONE SUR 1.680E-13 0.000E+00 0.000E+00 0.000E+00-1.000E+00 4.030E-11 6.120E-11 THYROID 1.040E-13 0.000E+00 0.000E+00 0.000E+00-1.000E+00 1.990E-08 3.940E-08 REMAINDER 9.660E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 8.020E-11 1.970E-10 EFFECTIVE 1.040E-13 0.000E+00 0.000E+00 0.000E+00-1.000E+00 7.140E-10 1.280E-09 SKIN(FGR) 1.360E-13 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 I-131 GONADS 1.780E-14 1.119E-11 1.789E-10 3.940E-16-1.000E+00 2.530E-11 4.070E-11 BREAST 2.040E-14 1.082E-11 1.730E-10 3.810E-16-1.000E+00 7.880E-11 1.210E-10 LUNGS 1.760E-14 1.016E-11 1.626E-10 3.580E-16-1.000E+00 6.570E-10 1.020E-10 RED MARR 1.680E-14 1.022E-11 1.635E-10 3.600E-16-1.000E+00 6.260E-11 9.440E-11 BONE SUR 3.450E-14 1.675E-11 2.679E-10 5.900E-16-1.000E+00 5.730E-11 8.720E-11 THYROID 1.810E-14 1.053E-11 1.685E-10 3.710E-16-1.000E+00 2.920E-07 4.760E-07 REMAINDER 1.670E-14 9.908E-12 1.585E-10 3.490E-16-1.000E+00 8.030E-11 1.570E-10 EFFECTIVE 1.820E-14 1.067E-11 1.707E-10 3.760E-16-1.000E+00 8.890E-09 1.440E-08 SKIN(FGR) 2.980E-14 1.825E-11 2.920E-10 6.430E-16-1.000E+00 0.000E+00 0.000E+00 I-132 GONADS 1.090E-13 2.523E-11 2.771E-11 2.320E-15-1.000E+00 9.950E-12 2.330E-11 BREAST 1.240E-13 2.414E-11 2.652E-11 2.220E-15-1.000E+00 1.410E-11 2.520E-11 LUNGS 1.090E-13 2.305E-11 2.532E-11 2.120E-15-1.000E+00 2.710E-10 2.640E-11 RED MARR 1.070E-13 2.360E-11 2.592E-11 2.170E-15-1.000E+00 1.400E-11 2.460E-11 BONE SUR 1.730E-13 3.327E-11 3.655E-11 3.060E-15-1.000E+00 1.240E-11 2.190E-11 THYROID 1.120E-13 2.381E-11 2.616E-11 2.190E-15-1.000E+00 1.740E-09 3.870E-09 REMAINDER 1.050E-13 2.283E-11 2.509E-11 2.100E-15-1.000E+00 3.780E-11 1.650E-10 EFFECTIVE 1.120E-13 2.403E-11 2.640E-11 2.210E-15-1.000E+00 1.030E-10 1.820E-10 SKIN(FGR) 1.580E-13 8.199E-11 9.007E-11 7.540E-15-1.000E+00 0.000E+00 0.000E+00 I-133 GONADS 2.870E-14 1.585E-11 6.748E-11 6.270E-16-1.000E+00 1.950E-11 3.630E-11 BREAST 3.280E-14 1.519E-11 6.468E-11 6.010E-16-1.000E+00 2.940E-11 4.680E-11 LUNGS 2.860E-14 1.446E-11 6.156E-11 5.720E-16-1.000E+00 8.200E-10 4.530E-11 RED MARR 2.770E-14 1.466E-11 6.242E-11 5.800E-16-1.000E+00 2.720E-11 4.300E-11 BONE SUR 4.870E-14 2.161E-11 9.202E-11 8.550E-16-1.000E+00 2.520E-11 4.070E-11 THYROID 2.930E-14 1.502E-11 6.393E-11 5.940E-16-1.000E+00 4.860E-08 9.100E-08 REMAINDER 2.730E-14 1.418E-11 6.038E-11 5.610E-16-1.000E+00 5.000E-11 1.550E-10 EFFECTIVE 2.940E-14 1.509E-11 6.425E-11 5.970E-16-1.000E+00 1.580E-09 2.800E-09 SKIN(FGR) 5.830E-14 1.150E-10 4.897E-10 4.550E-15-1.000E+00 0.000E+00 0.000E+00 I-134 GONADS 1.270E-13 1.200E-11 1.202E-11 2.640E-15-1.000E+00 4.250E-12 1.100E-11 BREAST 1.440E-13 1.145E-11 1.147E-11 2.520E-15-1.000E+00 6.170E-12 1.170E-11 LUNGS 1.270E-13 1.100E-11 1.102E-11 2.420E-15-1.000E+00 1.430E-10 1.260E-11 RED MARR 1.250E-13 1.127E-11 1.129E-11 2.480E-15-1.000E+00 6.080E-12 1.090E-11 BONE SUR 1.960E-13 1.568E-11 1.571E-11 3.450E-15-1.000E+00 5.310E-12 9.320E-12 THYROID 1.300E-13 1.127E-11 1.129E-11 2.480E-15-1.000E+00 2.880E-10 6.210E-10 REMAINDER 1.220E-13 1.091E-11 1.093E-11 2.400E-15-1.000E+00 2.270E-11 1.340E-10 EFFECTIVE 1.300E-13 1.150E-11 1.152E-11 2.530E-15-1.000E+00 3.550E-11 6.660E-11 SKIN(FGR) 1.870E-13 4.477E-11 4.485E-11 9.850E-15-1.000E+00 0.000E+00 0.000E+00 I-135 GONADS 8.078E-14 3.113E-11 5.489E-11 1.599E-15-1.000E+00 1.700E-11 3.610E-11 BREAST 9.143E-14 2.971E-11 5.240E-11 1.526E-15-1.000E+00 2.340E-11 3.850E-11 LUNGS 8.145E-14 2.886E-11 5.089E-11 1.482E-15-1.000E+00 4.410E-10 3.750E-11

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 83 RED MARR 8.054E-14 2.965E-11 5.228E-11 1.523E-15-1.000E+00 2.240E-11 3.650E-11 BONE SUR 1.184E-13 3.983E-11 7.024E-11 2.046E-15-1.000E+00 2.010E-11 3.360E-11 THYROID 8.324E-14 2.852E-11 5.030E-11 1.465E-15-1.000E+00 8.460E-09 1.790E-08 REMAINDER 7.861E-14 2.883E-11 5.084E-11 1.481E-15-1.000E+00 4.700E-11 1.540E-10 EFFECTIVE 8.294E-14 2.989E-11 5.271E-11 1.535E-15-1.000E+00 3.320E-10 6.080E-10 SKIN(FGR) 1.156E-13 9.826E-11 1.733E-10 5.047E-15-1.000E+00 0.000E+00 0.000E+00 Xe-131m GONADS 4.570E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 BREAST 6.020E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 LUNGS 2.670E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 RED MARR 2.270E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 BONE SUR 1.060E-15 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 THYROID 3.910E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 REMAINDER 2.710E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 3.890E-16 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 4.820E-15 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 Xe-133 GONADS 1.610E-15 1.465E-12 2.052E-11 5.200E-17-1.000E+00 0.000E+00 0.000E+00 BREAST 1.960E-15 1.505E-12 2.107E-11 5.340E-17-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.320E-15 1.045E-12 1.464E-11 3.710E-17-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.070E-15 8.791E-13 1.231E-11 3.120E-17-1.000E+00 0.000E+00 0.000E+00 BONE SUR 5.130E-15 4.254E-12 5.958E-11 1.510E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 1.510E-15 1.181E-12 1.653E-11 4.190E-17-1.000E+00 0.000E+00 0.000E+00 REMAINDER 1.240E-15 1.042E-12 1.460E-11 3.700E-17-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.560E-15 1.299E-12 1.819E-11 4.610E-17-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 4.970E-15 1.953E-12 2.734E-11 6.930E-17-1.000E+00 0.000E+00 0.000E+00 Xe-133m GONADS 1.420E-15 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 BREAST 1.700E-15 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.190E-15 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.100E-15 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 BONE SUR 3.230E-15 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 THYROID 1.360E-15 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 REMAINDER 1.150E-15 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.370E-15 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 1.040E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 Xe-135 GONADS 1.170E-14 5.455E-12 1.194E-11 2.530E-16-1.000E+00 0.000E+00 0.000E+00 BREAST 1.330E-14 5.325E-12 1.166E-11 2.470E-16-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.130E-14 4.959E-12 1.086E-11 2.300E-16-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.070E-14 4.959E-12 1.086E-11 2.300E-16-1.000E+00 0.000E+00 0.000E+00 BONE SUR 2.570E-14 9.120E-12 1.997E-11 4.230E-16-1.000E+00 0.000E+00 0.000E+00 THYROID 1.180E-14 5.023E-12 1.100E-11 2.330E-16-1.000E+00 0.000E+00 0.000E+00 REMAINDER 1.080E-14 4.829E-12 1.058E-11 2.240E-16-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 1.190E-14 5.217E-12 1.142E-11 2.420E-16-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 3.120E-14 4.506E-11 9.867E-11 2.090E-15-1.000E+00 0.000E+00 0.000E+00 Xe-135m GONADS 2.000E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 BREAST 2.290E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 LUNGS 1.980E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 RED MARR 1.910E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 BONE SUR 3.500E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 THYROID 2.040E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 REMAINDER 1.890E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 2.040E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 SKIN(FGR) 2.970E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 Xe-138 GONADS 5.590E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 BREAST 6.320E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 LUNGS 5.660E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 RED MARR 5.600E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 BONE SUR 8.460E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 THYROID 5.770E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 REMAINDER 5.490E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 EFFECTIVE 5.770E-14 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 84 SKIN(FGR) 1.070E-13 0.000E+00 0.000E+00 0.000E+00-1.000E+00 0.000E+00 0.000E+00 Cs-134 GONADS 7.400E-14 4.607E-11 9.646E-10 1.600E-15-1.000E+00 1.300E-08 2.060E-08 BREAST 8.430E-14 4.406E-11 9.224E-10 1.530E-15-1.000E+00 1.080E-08 1.720E-08 LUNGS 7.370E-14 4.204E-11 8.802E-10 1.460E-15-1.000E+00 1.180E-08 1.760E-08 RED MARR 7.190E-14 4.262E-11 8.922E-10 1.480E-15-1.000E+00 1.180E-08 1.870E-08 BONE SUR 1.200E-13 6.105E-11 1.278E-09 2.120E-15-1.000E+00 1.100E-08 1.740E-08 THYROID 7.570E-14 4.377E-11 9.163E-10 1.520E-15-1.000E+00 1.110E-08 1.760E-08 REMAINDER 7.060E-14 4.147E-11 8.681E-10 1.440E-15-1.000E+00 1.390E-08 2.210E-08 EFFECTIVE 7.570E-14 4.377E-11 9.163E-10 1.520E-15-1.000E+00 1.250E-08 1.980E-08 SKIN(FGR) 9.450E-14 6.249E-11 1.308E-09 2.170E-15-1.000E+00 0.000E+00 0.000E+00 Cs-136 GONADS 1.040E-13 6.223E-11 1.102E-09 2.180E-15-1.000E+00 1.880E-09 3.040E-09 BREAST 1.180E-13 5.966E-11 1.056E-09 2.090E-15-1.000E+00 1.670E-09 2.650E-09 LUNGS 1.040E-13 5.710E-11 1.011E-09 2.000E-15-1.000E+00 2.320E-09 2.620E-09 RED MARR 1.010E-13 5.824E-11 1.031E-09 2.040E-15-1.000E+00 1.860E-09 2.950E-09 BONE SUR 1.660E-13 8.422E-11 1.491E-09 2.950E-15-1.000E+00 1.700E-09 2.710E-09 THYROID 1.070E-13 5.852E-11 1.036E-09 2.050E-15-1.000E+00 1.730E-09 2.740E-09 REMAINDER 9.950E-14 5.652E-11 1.001E-09 1.980E-15-1.000E+00 2.190E-09 3.520E-09 EFFECTIVE 1.060E-13 5.966E-11 1.056E-09 2.090E-15-1.000E+00 1.980E-09 3.040E-09 SKIN(FGR) 1.250E-13 7.251E-11 1.284E-09 2.540E-15-1.000E+00 0.000E+00 0.000E+00 Cs-137 GONADS 2.669E-14 1.669E-11 3.530E-10 5.840E-16-1.000E+00 8.760E-09 1.390E-08 BREAST 3.047E-14 1.596E-11 3.376E-10 5.585E-16-1.000E+00 7.840E-09 1.240E-08 LUNGS 2.649E-14 1.517E-11 3.209E-10 5.309E-16-1.000E+00 8.820E-09 1.270E-08 RED MARR 2.583E-14 1.542E-11 3.260E-10 5.394E-16-1.000E+00 8.300E-09 1.320E-08 BONE SUR 4.382E-14 2.238E-11 4.734E-10 7.832E-16-1.000E+00 7.940E-09 1.260E-08 THYROID 2.725E-14 1.588E-11 3.358E-10 5.556E-16-1.000E+00 7.930E-09 1.260E-08 REMAINDER 2.536E-14 1.490E-11 3.152E-10 5.215E-16-1.000E+00 9.120E-09 1.450E-08 EFFECTIVE 2.725E-14 1.585E-11 3.353E-10 5.546E-16-1.000E+00 8.630E-09 1.350E-08 SKIN(FGR) 4.392E-14 5.253E-11 1.110E-09 1.836E-15-1.000E+00 0.000E+00 0.000E+00 Ba-139 GONADS 2.130E-15 3.368E-13 3.429E-13 4.790E-17-1.000E+00 2.560E-12 1.560E-12 BREAST 2.450E-15 3.297E-13 3.357E-13 4.690E-17-1.000E+00 2.460E-12 5.170E-13 LUNGS 2.030E-15 3.002E-13 3.057E-13 4.270E-17-1.000E+00 2.530E-10 3.890E-13 RED MARR 1.870E-15 2.932E-13 2.985E-13 4.170E-17-1.000E+00 3.410E-12 8.590E-13 BONE SUR 5.290E-15 6.841E-13 6.965E-13 9.730E-17-1.000E+00 2.490E-12 4.380E-13 THYROID 2.130E-15 3.044E-13 3.100E-13 4.330E-17-1.000E+00 2.400E-12 2.660E-13 REMAINDER 1.920E-15 2.932E-13 2.985E-13 4.170E-17-1.000E+00 4.820E-11 3.570E-10 EFFECTIVE 2.170E-15 3.227E-13 3.286E-13 4.590E-17-1.000E+00 4.640E-11 1.080E-10 SKIN(FGR) 6.160E-14 7.241E-11 7.373E-11 1.030E-14-1.000E+00 0.000E+00 0.000E+00 Ba-140 GONADS 8.410E-15 5.451E-12 9.607E-11 1.910E-16-1.000E+00 4.300E-10 9.960E-10 BREAST 9.640E-15 5.280E-12 9.305E-11 1.850E-16-1.000E+00 2.870E-10 1.590E-10 LUNGS 8.270E-15 4.852E-12 8.550E-11 1.700E-16-1.000E+00 1.660E-09 6.630E-11 RED MARR 7.930E-15 4.880E-12 8.601E-11 1.710E-16-1.000E+00 1.290E-09 4.390E-10 BONE SUR 1.550E-14 8.020E-12 1.413E-10 2.810E-16-1.000E+00 2.410E-09 5.530E-10 THYROID 8.530E-15 5.109E-12 9.003E-11 1.790E-16-1.000E+00 2.560E-10 5.250E-11 REMAINDER 7.890E-15 4.766E-12 8.399E-11 1.670E-16-1.000E+00 1.410E-09 7.370E-09 EFFECTIVE 8.580E-15 5.137E-12 9.053E-11 1.800E-16-1.000E+00 1.010E-09 2.560E-09 SKIN(FGR) 2.520E-14 5.565E-11 9.808E-10 1.950E-15-1.000E+00 0.000E+00 0.000E+00 La-140 GONADS 1.140E-13 6.027E-11 4.425E-10 2.240E-15-1.000E+00 4.540E-10 1.340E-09 BREAST 1.290E-13 5.758E-11 4.228E-10 2.140E-15-1.000E+00 1.450E-10 1.800E-10 LUNGS 1.150E-13 5.596E-11 4.109E-10 2.080E-15-1.000E+00 4.210E-09 4.010E-11 RED MARR 1.140E-13 5.731E-11 4.208E-10 2.130E-15-1.000E+00 2.140E-10 2.810E-10 BONE SUR 1.690E-13 7.776E-11 5.709E-10 2.890E-15-1.000E+00 1.410E-10 9.770E-11 THYROID 1.180E-13 5.462E-11 4.010E-10 2.030E-15-1.000E+00 6.870E-11 6.400E-12 REMAINDER 1.110E-13 5.569E-11 4.089E-10 2.070E-15-1.000E+00 2.120E-09 6.260E-09 EFFECTIVE 1.170E-13 5.812E-11 4.267E-10 2.160E-15-1.000E+00 1.310E-09 2.280E-09 SKIN(FGR) 1.660E-13 2.217E-10 1.628E-09 8.240E-15-1.000E+00 0.000E+00 0.000E+00 La-141 GONADS 2.330E-15 7.315E-13 9.675E-13 4.740E-17-1.000E+00 1.010E-11 3.770E-12 BREAST 2.640E-15 7.007E-13 9.267E-13 4.540E-17-1.000E+00 9.840E-12 7.070E-13 LUNGS 2.340E-15 6.713E-13 8.879E-13 4.350E-17-1.000E+00 6.460E-10 2.720E-13

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 85 RED MARR 2.310E-15 6.852E-13 9.063E-13 4.440E-17-1.000E+00 2.930E-11 1.070E-12 BONE SUR 3.490E-15 9.923E-13 1.312E-12 6.430E-17-1.000E+00 1.200E-10 6.060E-13 THYROID 2.390E-15 6.590E-13 8.716E-13 4.270E-17-1.000E+00 9.400E-12 5.290E-14 REMAINDER 2.260E-15 6.682E-13 8.838E-13 4.330E-17-1.000E+00 2.280E-10 1.240E-09 EFFECTIVE 2.390E-15 7.007E-13 9.267E-13 4.540E-17-1.000E+00 1.570E-10 3.740E-10 SKIN(FGR) 6.580E-14 1.667E-10 2.204E-10 1.080E-14-1.000E+00 0.000E+00 0.000E+00 La-142 GONADS 1.400E-13 1.978E-11 2.034E-11 2.540E-15-1.000E+00 1.660E-11 6.990E-11 BREAST 1.570E-13 1.885E-11 1.938E-11 2.420E-15-1.000E+00 1.130E-11 1.540E-11 LUNGS 1.420E-13 1.846E-11 1.898E-11 2.370E-15-1.000E+00 3.010E-10 8.400E-12 RED MARR 1.420E-13 1.900E-11 1.954E-11 2.440E-15-1.000E+00 1.360E-11 1.930E-11 BONE SUR 1.950E-13 2.484E-11 2.554E-11 3.190E-15-1.000E+00 1.110E-11 7.400E-12 THYROID 1.450E-13 1.768E-11 1.818E-11 2.270E-15-1.000E+00 8.740E-12 1.160E-12 REMAINDER 1.380E-13 1.853E-11 1.906E-11 2.380E-15-1.000E+00 8.070E-11 5.200E-10 EFFECTIVE 1.440E-13 1.916E-11 1.970E-11 2.460E-15-1.000E+00 6.840E-11 1.790E-10 SKIN(FGR) 2.160E-13 9.111E-11 9.368E-11 1.170E-14-1.000E+00 0.000E+00 0.000E+00 Ce-141 GONADS 3.380E-15 2.213E-12 4.332E-11 7.710E-17-1.000E+00 5.540E-11 1.080E-10 BREAST 3.930E-15 2.170E-12 4.247E-11 7.560E-17-1.000E+00 4.460E-11 1.110E-11 LUNGS 3.170E-15 1.951E-12 3.820E-11 6.800E-17-1.000E+00 1.670E-08 1.430E-12 RED MARR 2.830E-15 1.860E-12 3.641E-11 6.480E-17-1.000E+00 8.960E-11 3.390E-11 BONE SUR 9.410E-15 5.166E-12 1.011E-10 1.800E-16-1.000E+00 2.540E-10 2.300E-11 THYROID 3.350E-15 2.003E-12 3.922E-11 6.980E-17-1.000E+00 2.550E-11 1.800E-13 REMAINDER 2.980E-15 1.894E-12 3.708E-11 6.600E-17-1.000E+00 1.260E-09 2.500E-09 EFFECTIVE 3.430E-15 2.118E-12 4.146E-11 7.380E-17-1.000E+00 2.420E-09 7.830E-10 SKIN(FGR) 1.020E-14 3.788E-12 7.416E-11 1.320E-16-1.000E+00 0.000E+00 0.000E+00 Ce-143 GONADS 1.280E-14 7.900E-12 4.958E-11 2.980E-16-1.000E+00 7.530E-11 2.120E-10 BREAST 1.470E-14 7.688E-12 4.825E-11 2.900E-16-1.000E+00 1.660E-11 2.320E-11 LUNGS 1.230E-14 6.893E-12 4.325E-11 2.600E-16-1.000E+00 3.880E-09 3.820E-12 RED MARR 1.170E-14 6.787E-12 4.259E-11 2.560E-16-1.000E+00 2.960E-11 5.070E-11 BONE SUR 2.520E-14 1.323E-11 8.302E-11 4.990E-16-1.000E+00 1.640E-11 1.610E-11 THYROID 1.280E-14 7.211E-12 4.525E-11 2.720E-16-1.000E+00 6.230E-12 4.350E-13 REMAINDER 1.170E-14 6.734E-12 4.226E-11 2.540E-16-1.000E+00 1.420E-09 3.890E-09 EFFECTIVE 1.290E-14 7.396E-12 4.642E-11 2.790E-16-1.000E+00 9.160E-10 1.230E-09 SKIN(FGR) 3.960E-14 1.058E-10 6.638E-10 3.990E-15-1.000E+00 0.000E+00 0.000E+00 Ce-144 GONADS 2.725E-15 6.328E-13 1.319E-11 6.088E-17-1.000E+00 2.390E-10 6.987E-11 BREAST 3.129E-15 6.274E-13 1.307E-11 5.922E-17-1.000E+00 3.480E-10 1.223E-11 LUNGS 2.639E-15 5.228E-13 1.089E-11 5.362E-17-1.000E+00 7.911E-07 6.551E-12 RED MARR 2.507E-15 4.755E-13 9.907E-12 5.247E-17-1.000E+00 2.880E-09 8.923E-11 BONE SUR 5.441E-15 1.646E-12 3.429E-11 1.127E-16-1.000E+00 4.720E-09 1.280E-10 THYROID 2.753E-15 5.529E-13 1.152E-11 5.418E-17-1.000E+00 2.920E-10 5.154E-12 REMAINDER 2.534E-15 5.086E-13 1.060E-11 5.283E-17-1.000E+00 1.910E-08 1.890E-08 EFFECTIVE 2.773E-15 5.909E-13 1.231E-11 5.766E-17-1.000E+00 1.010E-07 5.711E-09 SKIN(FGR) 8.574E-14 7.648E-13 1.594E-11 1.250E-14-1.000E+00 0.000E+00 0.000E+00 Pr-143 GONADS 2.130E-17 2.264E-14 4.032E-13 7.930E-19-1.000E+00 4.370E-18 8.990E-18 BREAST 2.550E-17 2.330E-14 4.149E-13 8.160E-19-1.000E+00 2.220E-18 1.090E-18 LUNGS 1.860E-17 1.642E-14 2.923E-13 5.750E-19-1.000E+00 1.330E-08 1.910E-19 RED MARR 1.620E-17 1.493E-14 2.659E-13 5.230E-19-1.000E+00 1.480E-11 1.030E-12 BONE SUR 5.930E-17 5.454E-14 9.711E-13 1.910E-18-1.000E+00 1.490E-11 1.030E-12 THYROID 2.050E-17 1.802E-14 3.208E-13 6.310E-19-1.000E+00 1.680E-18 2.660E-20 REMAINDER 1.760E-17 1.642E-14 2.923E-13 5.750E-19-1.000E+00 1.970E-09 4.220E-09 EFFECTIVE 2.100E-17 2.002E-14 3.564E-13 7.010E-19-1.000E+00 2.190E-09 1.270E-09 SKIN(FGR) 1.760E-14 5.711E-11 1.017E-09 2.000E-15-1.000E+00 0.000E+00 0.000E+00 Nd-147 GONADS 6.130E-15 4.218E-12 7.235E-11 1.480E-16-1.000E+00 8.410E-11 1.790E-10 BREAST 7.120E-15 4.132E-12 7.088E-11 1.450E-16-1.000E+00 3.450E-11 1.870E-11 LUNGS 5.820E-15 3.648E-12 6.257E-11 1.280E-16-1.000E+00 1.060E-08 2.440E-12 RED MARR 5.400E-15 3.505E-12 6.013E-11 1.230E-16-1.000E+00 9.190E-11 5.050E-11 BONE SUR 1.320E-14 8.265E-12 1.418E-10 2.900E-16-1.000E+00 3.260E-10 2.220E-11 THYROID 6.120E-15 3.876E-12 6.648E-11 1.360E-16-1.000E+00 1.820E-11 2.640E-13 REMAINDER 5.530E-15 3.562E-12 6.111E-11 1.250E-16-1.000E+00 1.760E-09 3.760E-09 EFFECTIVE 6.190E-15 3.961E-12 6.795E-11 1.390E-16-1.000E+00 1.850E-09 1.180E-09

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 86 SKIN(FGR) 1.950E-14 3.135E-11 5.377E-10 1.100E-15-1.000E+00 0.000E+00 0.000E+00 Np-239 GONADS 7.530E-15 4.691E-12 4.380E-11 1.710E-16-1.000E+00 7.450E-11 1.620E-10 BREAST 8.730E-15 4.636E-12 4.329E-11 1.690E-16-1.000E+00 1.630E-11 1.720E-11 LUNGS 7.180E-15 4.115E-12 3.842E-11 1.500E-16-1.000E+00 2.360E-09 2.400E-12 RED MARR 6.500E-15 4.005E-12 3.740E-11 1.460E-16-1.000E+00 2.080E-10 4.660E-11 BONE SUR 2.000E-14 1.001E-11 9.349E-11 3.650E-16-1.000E+00 2.030E-09 3.590E-11 THYROID 7.520E-15 4.197E-12 3.919E-11 1.530E-16-1.000E+00 7.620E-12 2.070E-13 REMAINDER 6.760E-15 4.005E-12 3.740E-11 1.460E-16-1.000E+00 9.590E-10 2.770E-09 EFFECTIVE 7.690E-15 4.471E-12 4.175E-11 1.630E-16-1.000E+00 6.780E-10 8.820E-10 SKIN(FGR) 1.600E-14 7.215E-12 6.737E-11 2.630E-16-1.000E+00 0.000E+00 0.000E+00 Pu-241 GONADS 7.190E-20 6.653E-17 1.396E-15 2.310E-21-1.000E+00 2.760E-07 5.660E-11 BREAST 8.670E-20 7.229E-17 1.517E-15 2.510E-21-1.000E+00 2.140E-11 2.790E-15 LUNGS 6.480E-20 4.090E-17 8.584E-16 1.420E-21-1.000E+00 3.180E-06 4.480E-15 RED MARR 5.630E-20 4.003E-17 8.403E-16 1.390E-21-1.000E+00 1.430E-06 2.780E-10 BONE SUR 2.190E-19 1.385E-16 2.908E-15 4.810E-21-1.000E+00 1.780E-05 3.480E-09 THYROID 6.980E-20 4.522E-17 9.491E-16 1.570E-21-1.000E+00 9.150E-12 1.010E-15 REMAINDER 6.090E-20 4.291E-17 9.007E-16 1.490E-21-1.000E+00 6.020E-07 1.850E-10 EFFECTIVE 7.250E-20 5.558E-17 1.167E-15 1.930E-21-1.000E+00 1.340E-06 2.070E-10 SKIN(FGR) 1.170E-19 2.033E-16 4.268E-15 7.060E-21-1.000E+00 0.000E+00 0.000E+00 Cm-242 GONADS 7.830E-18 4.893E-14 1.013E-12 1.700E-18-1.000E+00 5.700E-07 5.200E-09 BREAST 1.480E-17 6.159E-14 1.275E-12 2.140E-18-1.000E+00 9.440E-10 8.950E-12 LUNGS 1.130E-18 3.022E-15 6.257E-14 1.050E-19-1.000E+00 1.550E-05 8.840E-12 RED MARR 1.890E-18 6.562E-15 1.359E-13 2.280E-19-1.000E+00 3.900E-06 3.570E-08 BONE SUR 1.060E-17 4.231E-14 8.759E-13 1.470E-18-1.000E+00 4.870E-05 4.460E-07 THYROID 4.910E-18 1.261E-14 2.610E-13 4.380E-19-1.000E+00 9.410E-10 8.820E-12 REMAINDER 2.270E-18 1.079E-14 2.235E-13 3.750E-19-1.000E+00 2.450E-06 4.020E-08 EFFECTIVE 5.690E-18 2.751E-14 5.697E-13 9.560E-19-1.000E+00 4.670E-06 3.100E-08 SKIN(FGR) 4.290E-17 2.700E-13 5.589E-12 9.380E-18-1.000E+00 0.000E+00 0.000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 87 Attachment E - RADTRAD Output Files NF-500_GNF2_0-24hr.o0 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:44:03 File information Plant file = D:\\Staum\\Fitz\\FHA\\0-24 hr\\NF-500_GNF2_0-24.psf Inventory file = D:\\Staum\\Fitz\\FHA\\JFHA_source_00.nif Release file = d:\\staum\\fitz\\fha\\jafha_rft_with_df.rft Dose Conversion file = d:\\staum\\fitz\\fha\\jafha_fg11&12.inp Radtrad 3.03 4/15/2001 JAF FHA Occurring In Reactor Bldg With RB Vent Release, Pool DF = 200, Peaking Factor =

1.82, Decay Time = 96 Hrs, CR Normal Flow Rate =2,112 cfm, No SGTS Filtration, and Plant Vent Release @ 99,800 cfm Nuclide Inventory File:

D:\\Staum\\Fitz\\FHA\\JFHA_source_00.nif Plant Power Level:

1.5780E+01 Compartments:

3 Compartment 1:

Reactor Building 3

2.6000E+06 0

0 0

0 0

Compartment 2:

Environment 2

0.0000E+00 0

0 0

0 0

Compartment 3:

Control Room 1

1.0100E+05 0

0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 88 0

0 0

Pathways:

3 Pathway 1:

Reactor Building to Environment 1

2 2

Pathway 2:

CR Air Intake 2

3 2

Pathway 3:

CR Exhaust to Environment 3

2 2

End of Plant Model File Scenario Description Name:

Plant Model Filename:

Source Term:

1 1 1.0000E+00 d:\\staum\\fitz\\fha\\jafha_fg11&12.inp d:\\staum\\fitz\\fha\\jafha_rft_with_df.rft 0.0000E+00 1

0.0000E+00 5.7000E-01 4.3000E-01 1.0000E+00 Overlying Pool:

0 0.0000E+00 0

0 0

0 Compartments:

3 Compartment 1:

0 1

0 0

0 0

0 0

0 Compartment 2:

0 1

0 0

0 0

0 0

0 Compartment 3:

1 1

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 89 0

0 0

0 0

0 0

Pathways:

3 Pathway 1:

0 0

0 0

0 1

3 0.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 2.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 2:

0 0

0 0

0 1

2 0.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 3:

0 0

0 0

0 1

2 0.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Dose Locations:

3 Location 1:

Exclusion Area Boundary 2

1 2

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 90 0.0000E+00 1.7900E-04 7.2000E+02 0.0000E+00 1

2 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 0

Location 2:

Low Population Zone 2

1 5

0.0000E+00 2.0000E-05 8.0000E+00 1.3400E-05 2.4000E+01 5.5900E-06 9.6000E+01 1.6000E-06 7.2000E+02 0.0000E+00 1

4 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 0.0000E+00 0

Location 3:

Control Room 3

0 1

2 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 1

4 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 0.0000E+00 Effective Volume Location:

1 6

0.0000E+00 3.5200E-03 3.3001E-02 9.2600E-07 8.0000E+00 6.7500E-07 2.4000E+01 3.3900E-07 9.6000E+01 1.2600E-07 7.2000E+02 0.0000E+00 Simulation Parameters:

6 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.0000E+00 7.2000E+02 0.0000E+00 Output Filename:

D:\\Staum\\Fitz\\FHA\\0-24 hr\\NF-500_GNF2_0-24.o0 1

1 1

0 0

End of Scenario File

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 91 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:44:03 Plant Description Number of Nuclides = 60 Inventory Power = 1.0000E+00 MWth Plant Power Level = 1.5780E+01 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.0000E+00

)

Name: Reactor Building Compartment volume = 2.6000E+06 (Cubic feet)

Compartment type is Normal Pathways into and out of compartment 1 Exit Pathway Number 1: Reactor Building to Environment Compartment number 2 Name: Environment Compartment type is Environment Pathways into and out of compartment 2 Inlet Pathway Number 1: Reactor Building to Environment Inlet Pathway Number 3: CR Exhaust to Environment Exit Pathway Number 2: CR Air Intake Compartment number 3 Name: Control Room Compartment volume = 1.0100E+05 (Cubic feet)

Compartment type is Control Room Pathways into and out of compartment 3 Inlet Pathway Number 2: CR Air Intake Exit Pathway Number 3: CR Exhaust to Environment Total number of pathways = 3 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:44:03 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled Release Fractions and Timings GAP EARLY IN-VESSEL LATE RELEASE RELEASE MASS 0.003600 hr 0.0000 hrs 0.0000 hrs (gm)

NOBLES 5.0000E-02 0.0000E+00 0.0000E+00 2.370E+00 IODINE 2.5000E-04 0.0000E+00 0.0000E+00 1.663E-03 CESIUM 1.2000E-01 0.0000E+00 0.0000E+00 0.000E+00 TELLURIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 STRONTIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 BARIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 RUTHENIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 92 CERIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 LANTHANUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 Inventory Power = 16. MWt Nuclide Group Specific half Whole Body Inhaled Inhaled Name Inventory life DCF Thyroid Effective (Ci/MWt) (s) (Sv-m3/Bq-s) (Sv/Bq) (Sv/Bq)

Kr-83m 1 3.890E+03 6.588E+03 1.500E-18 0.000E+00 0.000E+00 Kr-85 1 1.052E+03 3.383E+08 1.190E-16 0.000E+00 0.000E+00 Kr-85m 1 8.670E+03 1.613E+04 7.480E-15 0.000E+00 0.000E+00 Kr-87 1 1.740E+04 4.578E+03 4.120E-14 0.000E+00 0.000E+00 Kr-88 1 2.360E+04 1.022E+04 1.020E-13 0.000E+00 0.000E+00 Br-83 2 3.880E+03 8.604E+03 3.820E-16 3.290E-12 2.330E-11 Br-84 2 7.340E+03 1.908E+03 9.410E-14 3.120E-12 2.610E-11 I-130 2 7.070E+02 4.450E+04 1.040E-13 1.990E-08 7.140E-10 I-131 2 4.336E+04 6.947E+05 1.820E-14 2.920E-07 8.890E-09 I-132 2 3.960E+04 8.280E+03 1.120E-13 1.740E-09 1.030E-10 I-133 2 5.640E+04 7.488E+04 2.940E-14 4.860E-08 1.580E-09 I-134 2 6.430E+04 3.156E+03 1.300E-13 2.880E-10 3.550E-11 I-135 2 5.330E+04 2.380E+04 8.294E-14 8.460E-09 3.320E-10 Xe-131m 1 3.800E+02 1.028E+06 3.890E-16 0.000E+00 0.000E+00 Xe-133 1 5.630E+04 4.532E+05 1.560E-15 0.000E+00 0.000E+00 Xe-133m 1 1.730E+03 1.890E+05 1.370E-15 0.000E+00 0.000E+00 Xe-135 1 2.310E+04 3.272E+04 1.190E-14 0.000E+00 0.000E+00 Xe-135m 1 1.180E+04 9.174E+02 2.040E-14 0.000E+00 0.000E+00 Xe-138 1 4.990E+04 8.502E+02 5.770E-14 0.000E+00 0.000E+00 Nuclide Daughter Fraction Daughter Fraction Daughter Fraction Kr-85m Kr-85 0.21 none 0.00 none 0.00 Kr-87 Rb-87 1.00 none 0.00 none 0.00 Kr-88 Rb-88 1.00 none 0.00 none 0.00 Br-83 Kr-83m 1.00 none 0.00 none 0.00 I-131 Xe-131m 0.01 none 0.00 none 0.00 I-133 Xe-133m 0.03 Xe-133 0.97 none 0.00 I-135 Xe-135m 0.15 Xe-135 0.85 none 0.00 Xe-133m Xe-133 1.00 none 0.00 none 0.00 Xe-135 Cs-135 1.00 none 0.00 none 0.00 Xe-135m Xe-135 1.00 none 0.00 none 0.00 Xe-138 Cs-138 1.00 none 0.00 none 0.00 Iodine fractions Aerosol = 0.0000E+00 Elemental = 5.7000E-01 Organic = 4.3000E-01 COMPARTMENT DATA Compartment number 1: Reactor Building Compartment number 2: Environment Compartment number 3: Control Room PATHWAY DATA Pathway number 1: Reactor Building to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 2.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 93 Pathway number 2: CR Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 3: CR Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s

  • m^-3) 0.0000E+00 1.7900E-04 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 Location Low Population Zone is in compartment 2 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 0.0000E+00 2.0000E-05 8.0000E+00 1.3400E-05 2.4000E+01 5.5900E-06 9.6000E+01 1.6000E-06 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 0.0000E+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 0.0000E+00 3.5200E-03 3.3001E-02 9.2600E-07 8.0000E+00 6.7500E-07 2.4000E+01 3.3900E-07 9.6000E+01 1.2600E-07 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 Location Occupancy Factor Data Time (hr) Occupancy Factor

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 94 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 0.0000E+00 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.0000E+00 7.2000E+02 0.0000E+00 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:44:03 Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 1.4617E-02 6.0316E-02 1.6505E-02 Accumulated dose (rem) 1.4617E-02 6.0316E-02 1.6505E-02 Low Population Zone Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 1.6332E-03 6.7392E-03 1.8441E-03 Accumulated dose (rem) 1.6332E-03 6.7392E-03 1.8441E-03 Control Room Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 2.1166E-05 2.0850E-03 8.6430E-05 Accumulated dose (rem) 2.1166E-05 2.0850E-03 8.6430E-05 Control Room Compartment Nuclide Inventory:

Time (h) = 0.0036 Ci kg Atoms Decay Kr-83m 4.4402E-02 2.1521E-12 1.5615E+13 1.5120E+10 Kr-85 1.2021E-02 3.0640E-08 2.1708E+17 4.0915E+09 Kr-85m 9.9017E-02 1.2032E-11 8.5245E+13 3.3708E+10 Kr-87 1.9844E-01 7.0057E-12 4.8494E+13 6.7589E+10 Kr-88 2.6944E-01 2.1488E-11 1.4705E+14 9.1736E+10 Br-83 2.2145E-04 1.4018E-14 1.0171E+11 7.5402E+07 Br-84 4.1740E-04 5.9298E-15 4.2512E+10 1.4231E+08 I-130 4.0387E-05 2.0707E-14 9.5925E+10 1.3747E+07 I-131 2.4774E-03 1.9983E-11 9.1862E+13 8.4319E+08

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 95 I-132 2.2601E-03 2.1896E-13 9.9893E+11 7.6955E+08 I-133 3.2220E-03 2.8443E-12 1.2879E+13 1.0967E+09 I-134 3.6634E-03 1.3732E-13 6.1715E+11 1.2481E+09 I-135 3.0442E-03 8.6682E-13 3.8668E+12 1.0362E+09 Xe-131m 4.3423E-03 5.1841E-11 2.3832E+14 1.4779E+09 Xe-133 6.4333E-01 3.4369E-09 1.5562E+16 2.1897E+11 Xe-133m 1.9768E-02 4.4056E-11 1.9948E+14 6.7283E+09 Xe-135 2.6396E-01 1.0336E-10 4.6108E+14 8.9840E+10 Xe-135m 1.3369E-01 1.4677E-12 6.5470E+12 4.5661E+10 Xe-138 5.6422E-01 5.8678E-12 2.5606E+13 1.9276E+11 Control Room Transport Group Inventory:

Time (h) = 0.0036 Atmosphere Sump Noble gases (atoms) 2.3387E+17 0.0000E+00 Elemental I (atoms) 6.2964E+13 0.0000E+00 Organic I (atoms) 4.7499E+13 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 1.0905E-12 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 1.3062E-12 Total I (Ci) 1.4667E-02 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 0.0036 Filtered Transported Noble gases (atoms) 0.0000E+00 2.3423E+17 Elemental I (atoms) 0.0000E+00 6.3062E+13 Organic I (atoms) 0.0000E+00 4.7573E+13 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 0.0036 Filtered Transported Noble gases (atoms) 3.5241E+14 0.0000E+00 Elemental I (atoms) 9.4880E+10 0.0000E+00 Organic I (atoms) 7.1576E+10 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.5196E+00 1.4313E+01 2.9669E+00 Accumulated dose (rem) 2.5343E+00 1.4373E+01 2.9835E+00 Low Population Zone Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.8152E-01 1.5992E+00 3.3150E-01 Accumulated dose (rem) 2.8316E-01 1.6059E+00 3.3335E-01 Control Room Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.2901E-01 5.2541E+01 1.9695E+00 Accumulated dose (rem) 3.2903E-01 5.2543E+01 1.9696E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Decay Kr-83m 8.9020E-02 4.3146E-12 3.1305E+13 1.7008E+14 Kr-85 5.1119E-02 1.3030E-07 9.2312E+17 5.7212E+13 Kr-85m 3.0917E-01 3.7568E-11 2.6617E+14 4.2936E+14 Kr-87 2.8423E-01 1.0034E-11 6.9459E+13 6.9682E+14 Kr-88 7.0386E-01 5.6133E-11 3.8413E+14 1.1100E+15

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 96 Br-83 5.2779E-04 3.3409E-14 2.4240E+11 8.8926E+11 Br-84 1.3040E-04 1.8525E-15 1.3281E+10 1.0514E+12 I-130 1.5355E-04 7.8729E-14 3.6471E+11 1.8571E+11 I-131 1.0459E-02 8.4367E-11 3.8784E+14 1.1764E+13 I-132 5.2658E-03 5.1015E-13 2.3274E+12 9.0189E+12 I-133 1.2819E-02 1.1317E-11 5.1240E+13 1.5023E+13 I-134 3.2136E-03 1.2046E-13 5.4138E+11 1.1440E+13 I-135 1.0500E-02 2.9898E-12 1.3337E+13 1.3593E+13 Xe-131m 1.8376E-02 2.1939E-10 1.0085E+15 2.0635E+13 Xe-133 2.7068E+00 1.4461E-08 6.5478E+16 3.0517E+15 Xe-133m 8.1885E-02 1.8249E-10 8.2631E+14 9.3319E+13 Xe-135 9.7964E-01 3.8361E-10 1.7112E+15 1.2100E+15 Xe-135m 4.3535E-03 4.7792E-14 2.1319E+11 2.1937E+14 Xe-138 6.8449E-03 7.1185E-14 3.1064E+11 8.7294E+14 Control Room Transport Group Inventory:

Time (h) = 2.0000 Atmosphere Sump Noble gases (atoms) 9.9290E+17 0.0000E+00 Elemental I (atoms) 2.5987E+14 0.0000E+00 Organic I (atoms) 1.9604E+14 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 4.5216E-12 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 5.2462E-12 Total I (Ci) 4.2258E-02 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 2.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.1480E+19 Elemental I (atoms) 0.0000E+00 3.0906E+15 Organic I (atoms) 0.0000E+00 2.3315E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 2.0000 Filtered Transported Noble gases (atoms) 1.0481E+19 0.0000E+00 Elemental I (atoms) 2.7952E+15 0.0000E+00 Organic I (atoms) 2.1087E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.5343E+00 1.4373E+01 2.9835E+00 Low Population Zone Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.8316E-01 1.6059E+00 3.3335E-01 Control Room Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.3852E-02 4.8724E+00 1.6516E-01 Accumulated dose (rem) 3.4288E-01 5.7415E+01 2.1348E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Decay Kr-83m 5.0231E-06 2.4346E-16 1.7665E+09 1.7690E+14

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 97 Kr-85 2.7495E-05 7.0079E-11 4.9650E+14 6.2303E+13 Kr-85m 6.5720E-05 7.9859E-15 5.6579E+10 4.5677E+14 Kr-87 5.8078E-06 2.0504E-16 1.4193E+09 7.1656E+14 Kr-88 8.7533E-05 6.9807E-15 4.7772E+10 1.1687E+15 Br-83 4.9820E-08 3.1536E-18 2.2882E+07 9.3196E+11 I-130 5.8990E-08 3.0246E-17 1.4011E+08 2.0035E+11 I-131 5.5057E-06 4.4410E-14 2.0415E+11 1.2803E+13 I-132 4.6434E-07 4.4985E-17 2.0523E+08 9.4418E+12 I-133 5.6455E-06 4.9836E-15 2.2565E+10 1.6266E+13 I-134 1.5044E-08 5.6395E-19 2.5345E+06 1.1637E+13 I-135 3.0102E-06 8.5716E-16 3.8236E+09 1.4559E+13 Xe-131m 9.7418E-06 1.1630E-13 5.3466E+11 2.2462E+13 Xe-133 1.4101E-03 7.5336E-12 3.4111E+13 3.3201E+15 Xe-133m 4.0703E-05 9.0711E-14 4.1073E+11 1.0139E+14 Xe-135 3.3500E-04 1.3118E-13 5.8517E+11 1.3021E+15 Xe-135m 5.3653E-07 5.8899E-18 2.6274E+07 2.1960E+14 Control Room Transport Group Inventory:

Time (h) = 8.0000 Atmosphere Sump Noble gases (atoms) 5.3225E+14 0.0000E+00 Elemental I (atoms) 1.3162E+11 0.0000E+00 Organic I (atoms) 9.9293E+10 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 2.2851E-15 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 2.5462E-15 Total I (Ci) 1.4641E-05 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 8.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.1480E+19 Elemental I (atoms) 0.0000E+00 3.0906E+15 Organic I (atoms) 0.0000E+00 2.3315E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 8.0000 Filtered Transported Noble gases (atoms) 1.1473E+19 0.0000E+00 Elemental I (atoms) 3.0527E+15 0.0000E+00 Organic I (atoms) 2.3029E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.5343E+00 1.4373E+01 2.9835E+00 Low Population Zone Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.8316E-01 1.6059E+00 3.3335E-01 Control Room Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.2983E-06 2.4678E-03 7.8455E-05 Accumulated dose (rem) 3.4289E-01 5.7418E+01 2.1348E+00 Control Room Compartment Nuclide Inventory:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 98 Time (h) = 24.0000 Ci kg Atoms Decay Kr-85 5.2598E-14 1.3406E-19 9.4983E+05 6.2306E+13 Xe-133 2.4770E-12 1.3233E-20 5.9919E+04 3.3203E+15 Control Room Transport Group Inventory:

Time (h) = 24.0000 Atmosphere Sump Noble gases (atoms) 1.0117E+06 0.0000E+00 Elemental I (atoms) 2.2548E+02 0.0000E+00 Organic I (atoms) 1.7010E+02 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 3.8571E-24 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 4.1010E-24 Total I (Ci) 1.7365E-14 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 24.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.1480E+19 Elemental I (atoms) 0.0000E+00 3.0906E+15 Organic I (atoms) 0.0000E+00 2.3315E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 24.0000 Filtered Transported Noble gases (atoms) 1.1473E+19 0.0000E+00 Elemental I (atoms) 3.0528E+15 0.0000E+00 Organic I (atoms) 2.3030E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.5343E+00 1.4373E+01 2.9835E+00 Low Population Zone Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.8316E-01 1.6059E+00 3.3335E-01 Control Room Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.3877E-16 2.8253E-12 8.7381E-14 Accumulated dose (rem) 3.4289E-01 5.7418E+01 2.1348E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 96.0000 Ci kg Atoms Decay Control Room Transport Group Inventory:

Time (h) = 96.0000 Atmosphere Sump Noble gases (atoms) 5.8078E-34 0.0000E+00 Elemental I (atoms) 9.5880E-38 0.0000E+00 Organic I (atoms) 7.2331E-38 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 1.5930E-63 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 1.6049E-63 Total I (Ci) 4.8374E-54 CR Air Intake Transport Group Inventory:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 99 Pathway Time (h) = 96.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.1480E+19 Elemental I (atoms) 0.0000E+00 3.0906E+15 Organic I (atoms) 0.0000E+00 2.3315E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 96.0000 Filtered Transported Noble gases (atoms) 1.1473E+19 0.0000E+00 Elemental I (atoms) 3.0528E+15 0.0000E+00 Organic I (atoms) 2.3030E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.5343E+00 1.4373E+01 2.9835E+00 Low Population Zone Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.8316E-01 1.6059E+00 3.3335E-01 Control Room Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.1619E-55 7.7857E-52 2.3839E-53 Accumulated dose (rem) 3.4289E-01 5.7418E+01 2.1348E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 720.0000 Ci kg Atoms Decay Control Room Transport Group Inventory:

Time (h) = 720.0000 Atmosphere Sump Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 0.0000E+00 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 0.0000E+00 Total I (Ci) 0.0000E+00 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 720.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.1480E+19 Elemental I (atoms) 0.0000E+00 3.0906E+15 Organic I (atoms) 0.0000E+00 2.3315E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 720.0000 Filtered Transported Noble gases (atoms) 1.1473E+19 0.0000E+00 Elemental I (atoms) 3.0528E+15 0.0000E+00 Organic I (atoms) 2.3030E+15 0.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 100 Aerosols (kg) 0.0000E+00 0.0000E+00 838 I-131 Summary Reactor Building Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 0.000 2.6380E+01 1.6880E-02 5.9212E-05 0.004 1.7035E+02 7.0715E-01 2.4774E-03 0.400 6.8270E+01 1.0261E+02 7.8199E-02 0.700 3.4174E+01 1.3664E+02 5.3638E-02 1.000 1.7107E+01 1.5368E+02 3.6787E-02 1.300 8.5631E+00 1.6221E+02 2.5227E-02 1.600 4.2865E+00 1.6648E+02 1.7299E-02 1.900 2.1457E+00 1.6861E+02 1.1861E-02 2.000 1.7037E+00 1.6906E+02 1.0459E-02 2.300 1.7019E+00 1.6906E+02 7.1709E-03 2.600 1.7000E+00 1.6906E+02 4.9163E-03 2.900 1.6982E+00 1.6906E+02 3.3706E-03 3.200 1.6964E+00 1.6906E+02 2.3108E-03 3.500 1.6945E+00 1.6906E+02 1.5843E-03 3.800 1.6927E+00 1.6906E+02 1.0862E-03 4.100 1.6909E+00 1.6906E+02 7.4467E-04 4.400 1.6891E+00 1.6906E+02 5.1054E-04 4.700 1.6872E+00 1.6906E+02 3.5002E-04 5.000 1.6854E+00 1.6906E+02 2.3997E-04 5.300 1.6836E+00 1.6906E+02 1.6452E-04 5.600 1.6818E+00 1.6906E+02 1.1279E-04 5.900 1.6800E+00 1.6906E+02 7.7331E-05 6.200 1.6782E+00 1.6906E+02 5.3017E-05 6.500 1.6764E+00 1.6906E+02 3.6348E-05 6.800 1.6746E+00 1.6906E+02 2.4920E-05 7.100 1.6728E+00 1.6906E+02 1.7085E-05 7.400 1.6710E+00 1.6906E+02 1.1713E-05 7.700 1.6692E+00 1.6906E+02 8.0306E-06 8.000 1.6674E+00 1.6906E+02 5.5057E-06 8.300 1.6656E+00 1.6906E+02 3.7746E-06 8.600 1.6638E+00 1.6906E+02 2.5879E-06 8.900 1.6620E+00 1.6906E+02 1.7742E-06 9.200 1.6602E+00 1.6906E+02 1.2164E-06 9.500 1.6584E+00 1.6906E+02 8.3394E-07 9.800 1.6566E+00 1.6906E+02 5.7174E-07 10.100 1.6548E+00 1.6906E+02 3.9198E-07 10.400 1.6531E+00 1.6906E+02 2.6874E-07 24.000 1.5742E+00 1.6906E+02 9.9452E-15 96.000 1.2155E+00 1.6906E+02 4.5000E-54 720.000 1.2920E-01 1.6906E+02 0.0000E+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone Control Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 0.000 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.004 6.0316E-02 1.6505E-02 6.7392E-03 1.8441E-03 2.0850E-03 8.6430E-05 0.400 8.7439E+00 2.0969E+00 9.7697E-01 2.3429E-01 2.0452E+01 8.0990E-01 0.700 1.1634E+01 2.6009E+00 1.2999E+00 2.9061E-01 3.2135E+01 1.2445E+00 1.000 1.3077E+01 2.8165E+00 1.4611E+00 3.1469E-01 4.0126E+01 1.5332E+00 1.300 1.3797E+01 2.9135E+00 1.5416E+00 3.2553E-01 4.5591E+01 1.7272E+00 1.600 1.4157E+01 2.9583E+00 1.5817E+00 3.3054E-01 4.9329E+01 1.8582E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 101 1.900 1.4336E+01 2.9793E+00 1.6018E+00 3.3288E-01 5.1885E+01 1.9469E+00 2.000 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.2543E+01 1.9696E+00 2.300 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.4083E+01 2.0225E+00 2.600 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.5137E+01 2.0584E+00 2.900 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.5858E+01 2.0828E+00 3.200 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.6350E+01 2.0994E+00 3.500 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.6688E+01 2.1107E+00 3.800 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.6918E+01 2.1184E+00 4.100 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7076E+01 2.1236E+00 4.400 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7184E+01 2.1272E+00 4.700 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7258E+01 2.1296E+00 5.000 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7308E+01 2.1313E+00 5.300 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7343E+01 2.1324E+00 5.600 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7367E+01 2.1332E+00 5.900 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7383E+01 2.1337E+00 6.200 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7394E+01 2.1341E+00 6.500 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7401E+01 2.1343E+00 6.800 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7407E+01 2.1345E+00 7.100 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7410E+01 2.1346E+00 7.400 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7413E+01 2.1347E+00 7.700 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7414E+01 2.1347E+00 8.000 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7415E+01 2.1348E+00 8.300 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7416E+01 2.1348E+00 8.600 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7417E+01 2.1348E+00 8.900 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7417E+01 2.1348E+00 9.200 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7417E+01 2.1348E+00 9.500 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7417E+01 2.1348E+00 9.800 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7418E+01 2.1348E+00 10.100 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7418E+01 2.1348E+00 10.400 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7418E+01 2.1348E+00 24.000 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7418E+01 2.1348E+00 96.000 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7418E+01 2.1348E+00 720.000 1.4373E+01 2.9835E+00 1.6059E+00 3.3335E-01 5.7418E+01 2.1348E+00 Worst Two-Hour Doses Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 0.0 2.5343E+00 1.4373E+01 2.9835E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 102 NF-500_GNF3_0-24hr.o0 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:45:18 File information Plant file = D:\\Staum\\Fitz\\FHA\\0-24 hr\\NF-500_GNF3_0-24.psf Inventory file = D:\\Staum\\Fitz\\FHA\\JFHA_source_00.nif Release file = d:\\staum\\fitz\\fha\\jafha_rft_with_df.rft Dose Conversion file = d:\\staum\\fitz\\fha\\jafha_fg11&12.inp Radtrad 3.03 4/15/2001 JAF FHA Occurring In Reactor Bldg With RB Vent Release, Pool DF = 200, Peaking Factor =

1.82, Decay Time = 96 Hrs, CR Normal Flow Rate =2,112 cfm, No SGTS Filtration, and Plant Vent Release @ 99,800 cfm Nuclide Inventory File:

D:\\Staum\\Fitz\\FHA\\JFHA_source_00.nif Plant Power Level:

1.5027E+01 Compartments:

3 Compartment 1:

Reactor Building 3

2.6000E+06 0

0 0

0 0

Compartment 2:

Environment 2

0.0000E+00 0

0 0

0 0

Compartment 3:

Control Room 1

1.0100E+05 0

0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 103 0

0 0

Pathways:

3 Pathway 1:

Reactor Building to Environment 1

2 2

Pathway 2:

CR Air Intake 2

3 2

Pathway 3:

CR Exhaust to Environment 3

2 2

End of Plant Model File Scenario Description Name:

Plant Model Filename:

Source Term:

1 1 1.0000E+00 d:\\staum\\fitz\\fha\\jafha_fg11&12.inp d:\\staum\\fitz\\fha\\jafha_rft_with_df.rft 0.0000E+00 1

0.0000E+00 5.7000E-01 4.3000E-01 1.0000E+00 Overlying Pool:

0 0.0000E+00 0

0 0

0 Compartments:

3 Compartment 1:

0 1

0 0

0 0

0 0

0 Compartment 2:

0 1

0 0

0 0

0 0

0 Compartment 3:

1 1

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 104 0

0 0

0 0

0 0

Pathways:

3 Pathway 1:

0 0

0 0

0 1

3 0.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 2.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 2:

0 0

0 0

0 1

2 0.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 3:

0 0

0 0

0 1

2 0.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Dose Locations:

3 Location 1:

Exclusion Area Boundary 2

1 2

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 105 0.0000E+00 1.7900E-04 7.2000E+02 0.0000E+00 1

2 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 0

Location 2:

Low Population Zone 2

1 5

0.0000E+00 2.0000E-05 8.0000E+00 1.3400E-05 2.4000E+01 5.5900E-06 9.6000E+01 1.6000E-06 7.2000E+02 0.0000E+00 1

4 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 0.0000E+00 0

Location 3:

Control Room 3

0 1

2 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 1

4 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 0.0000E+00 Effective Volume Location:

1 6

0.0000E+00 3.5200E-03 3.3001E-02 9.2600E-07 8.0000E+00 6.7500E-07 2.4000E+01 3.3900E-07 9.6000E+01 1.2600E-07 7.2000E+02 0.0000E+00 Simulation Parameters:

6 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.0000E+00 7.2000E+02 0.0000E+00 Output Filename:

D:\\Staum\\Fitz\\FHA\\0-24 hr\\NF-500_GNF2_0-24.o0 1

1 1

0 0

End of Scenario File

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 106 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:45:18 Plant Description Number of Nuclides = 60 Inventory Power = 1.0000E+00 MWth Plant Power Level = 1.5027E+01 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.0000E+00

)

Name: Reactor Building Compartment volume = 2.6000E+06 (Cubic feet)

Compartment type is Normal Pathways into and out of compartment 1 Exit Pathway Number 1: Reactor Building to Environment Compartment number 2 Name: Environment Compartment type is Environment Pathways into and out of compartment 2 Inlet Pathway Number 1: Reactor Building to Environment Inlet Pathway Number 3: CR Exhaust to Environment Exit Pathway Number 2: CR Air Intake Compartment number 3 Name: Control Room Compartment volume = 1.0100E+05 (Cubic feet)

Compartment type is Control Room Pathways into and out of compartment 3 Inlet Pathway Number 2: CR Air Intake Exit Pathway Number 3: CR Exhaust to Environment Total number of pathways = 3 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:45:18 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled Release Fractions and Timings GAP EARLY IN-VESSEL LATE RELEASE RELEASE MASS 0.003600 hr 0.0000 hrs 0.0000 hrs (gm)

NOBLES 5.0000E-02 0.0000E+00 0.0000E+00 2.257E+00 IODINE 2.5000E-04 0.0000E+00 0.0000E+00 1.584E-03 CESIUM 1.2000E-01 0.0000E+00 0.0000E+00 0.000E+00 TELLURIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 STRONTIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 BARIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 RUTHENIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 107 CERIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 LANTHANUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 Inventory Power = 15. MWt Nuclide Group Specific half Whole Body Inhaled Inhaled Name Inventory life DCF Thyroid Effective (Ci/MWt) (s) (Sv-m3/Bq-s) (Sv/Bq) (Sv/Bq)

Kr-83m 1 3.890E+03 6.588E+03 1.500E-18 0.000E+00 0.000E+00 Kr-85 1 1.052E+03 3.383E+08 1.190E-16 0.000E+00 0.000E+00 Kr-85m 1 8.670E+03 1.613E+04 7.480E-15 0.000E+00 0.000E+00 Kr-87 1 1.740E+04 4.578E+03 4.120E-14 0.000E+00 0.000E+00 Kr-88 1 2.360E+04 1.022E+04 1.020E-13 0.000E+00 0.000E+00 Br-83 2 3.880E+03 8.604E+03 3.820E-16 3.290E-12 2.330E-11 Br-84 2 7.340E+03 1.908E+03 9.410E-14 3.120E-12 2.610E-11 I-130 2 7.070E+02 4.450E+04 1.040E-13 1.990E-08 7.140E-10 I-131 2 4.336E+04 6.947E+05 1.820E-14 2.920E-07 8.890E-09 I-132 2 3.960E+04 8.280E+03 1.120E-13 1.740E-09 1.030E-10 I-133 2 5.640E+04 7.488E+04 2.940E-14 4.860E-08 1.580E-09 I-134 2 6.430E+04 3.156E+03 1.300E-13 2.880E-10 3.550E-11 I-135 2 5.330E+04 2.380E+04 8.294E-14 8.460E-09 3.320E-10 Xe-131m 1 3.800E+02 1.028E+06 3.890E-16 0.000E+00 0.000E+00 Xe-133 1 5.630E+04 4.532E+05 1.560E-15 0.000E+00 0.000E+00 Xe-133m 1 1.730E+03 1.890E+05 1.370E-15 0.000E+00 0.000E+00 Xe-135 1 2.310E+04 3.272E+04 1.190E-14 0.000E+00 0.000E+00 Xe-135m 1 1.180E+04 9.174E+02 2.040E-14 0.000E+00 0.000E+00 Xe-138 1 4.990E+04 8.502E+02 5.770E-14 0.000E+00 0.000E+00 Nuclide Daughter Fraction Daughter Fraction Daughter Fraction Kr-85m Kr-85 0.21 none 0.00 none 0.00 Kr-87 Rb-87 1.00 none 0.00 none 0.00 Kr-88 Rb-88 1.00 none 0.00 none 0.00 Br-83 Kr-83m 1.00 none 0.00 none 0.00 I-131 Xe-131m 0.01 none 0.00 none 0.00 I-133 Xe-133m 0.03 Xe-133 0.97 none 0.00 I-135 Xe-135m 0.15 Xe-135 0.85 none 0.00 Xe-133m Xe-133 1.00 none 0.00 none 0.00 Xe-135 Cs-135 1.00 none 0.00 none 0.00 Xe-135m Xe-135 1.00 none 0.00 none 0.00 Xe-138 Cs-138 1.00 none 0.00 none 0.00 Iodine fractions Aerosol = 0.0000E+00 Elemental = 5.7000E-01 Organic = 4.3000E-01 COMPARTMENT DATA Compartment number 1: Reactor Building Compartment number 2: Environment Compartment number 3: Control Room PATHWAY DATA Pathway number 1: Reactor Building to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 2.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 108 Pathway number 2: CR Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 3: CR Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s

  • m^-3) 0.0000E+00 1.7900E-04 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 Location Low Population Zone is in compartment 2 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 0.0000E+00 2.0000E-05 8.0000E+00 1.3400E-05 2.4000E+01 5.5900E-06 9.6000E+01 1.6000E-06 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 0.0000E+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 0.0000E+00 3.5200E-03 3.3001E-02 9.2600E-07 8.0000E+00 6.7500E-07 2.4000E+01 3.3900E-07 9.6000E+01 1.2600E-07 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 Location Occupancy Factor Data Time (hr) Occupancy Factor

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 109 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 0.0000E+00 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.0000E+00 7.2000E+02 0.0000E+00 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:45:18 Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 1.3919E-02 5.7438E-02 1.5717E-02 Accumulated dose (rem) 1.3919E-02 5.7438E-02 1.5717E-02 Low Population Zone Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 1.5552E-03 6.4176E-03 1.7561E-03 Accumulated dose (rem) 1.5552E-03 6.4176E-03 1.7561E-03 Control Room Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 2.0156E-05 1.9855E-03 8.2306E-05 Accumulated dose (rem) 2.0156E-05 1.9855E-03 8.2306E-05 Control Room Compartment Nuclide Inventory:

Time (h) = 0.0036 Ci kg Atoms Decay Kr-83m 4.2283E-02 2.0494E-12 1.4870E+13 1.4398E+10 Kr-85 1.1448E-02 2.9178E-08 2.0672E+17 3.8963E+09 Kr-85m 9.4293E-02 1.1458E-11 8.1177E+13 3.2100E+10 Kr-87 1.8897E-01 6.6714E-12 4.6179E+13 6.4363E+10 Kr-88 2.5658E-01 2.0463E-11 1.4003E+14 8.7358E+10 Br-83 2.1089E-04 1.3349E-14 9.6856E+10 7.1804E+07 Br-84 3.9749E-04 5.6468E-15 4.0483E+10 1.3552E+08 I-130 3.8459E-05 1.9719E-14 9.1348E+10 1.3091E+07 I-131 2.3591E-03 1.9029E-11 8.7478E+13 8.0296E+08

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 110 I-132 2.1523E-03 2.0851E-13 9.5126E+11 7.3282E+08 I-133 3.0683E-03 2.7086E-12 1.2264E+13 1.0444E+09 I-134 3.4885E-03 1.3077E-13 5.8770E+11 1.1886E+09 I-135 2.8989E-03 8.2546E-13 3.6823E+12 9.8680E+08 Xe-131m 4.1350E-03 4.9367E-11 2.2694E+14 1.4074E+09 Xe-133 6.1263E-01 3.2729E-09 1.4820E+16 2.0852E+11 Xe-133m 1.8825E-02 4.1953E-11 1.8996E+14 6.4073E+09 Xe-135 2.5136E-01 9.8429E-11 4.3908E+14 8.5553E+10 Xe-135m 1.2731E-01 1.3976E-12 6.2346E+12 4.3482E+10 Xe-138 5.3729E-01 5.5878E-12 2.4384E+13 1.8357E+11 Control Room Transport Group Inventory:

Time (h) = 0.0036 Atmosphere Sump Noble gases (atoms) 2.2271E+17 0.0000E+00 Elemental I (atoms) 5.9960E+13 0.0000E+00 Organic I (atoms) 4.5233E+13 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 1.0385E-12 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 1.2439E-12 Total I (Ci) 1.3967E-02 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 0.0036 Filtered Transported Noble gases (atoms) 0.0000E+00 2.2305E+17 Elemental I (atoms) 0.0000E+00 6.0053E+13 Organic I (atoms) 0.0000E+00 4.5303E+13 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 0.0036 Filtered Transported Noble gases (atoms) 3.3559E+14 0.0000E+00 Elemental I (atoms) 9.0353E+10 0.0000E+00 Organic I (atoms) 6.8161E+10 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.3994E+00 1.3630E+01 2.8254E+00 Accumulated dose (rem) 2.4133E+00 1.3687E+01 2.8411E+00 Low Population Zone Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.6809E-01 1.5229E+00 3.1568E-01 Accumulated dose (rem) 2.6965E-01 1.5293E+00 3.1744E-01 Control Room Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.1331E-01 5.0034E+01 1.8755E+00 Accumulated dose (rem) 3.1333E-01 5.0036E+01 1.8756E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Decay Kr-83m 8.4772E-02 4.1087E-12 2.9811E+13 1.6197E+14 Kr-85 4.8680E-02 1.2408E-07 8.7907E+17 5.4482E+13 Kr-85m 2.9442E-01 3.5776E-11 2.5347E+14 4.0887E+14 Kr-87 2.7067E-01 9.5556E-12 6.6144E+13 6.6357E+14 Kr-88 6.7027E-01 5.3454E-11 3.6580E+14 1.0571E+15

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 111 Br-83 5.0260E-04 3.1815E-14 2.3084E+11 8.4682E+11 Br-84 1.2418E-04 1.7641E-15 1.2647E+10 1.0012E+12 I-130 1.4622E-04 7.4972E-14 3.4730E+11 1.7685E+11 I-131 9.9603E-03 8.0341E-11 3.6933E+14 1.1203E+13 I-132 5.0145E-03 4.8580E-13 2.2163E+12 8.5885E+12 I-133 1.2208E-02 1.0777E-11 4.8795E+13 1.4306E+13 I-134 3.0602E-03 1.1471E-13 5.1554E+11 1.0894E+13 I-135 9.9987E-03 2.8471E-12 1.2701E+13 1.2945E+13 Xe-131m 1.7499E-02 2.0892E-10 9.6041E+14 1.9650E+13 Xe-133 2.5777E+00 1.3771E-08 6.2354E+16 2.9061E+15 Xe-133m 7.7978E-02 1.7378E-10 7.8688E+14 8.8866E+13 Xe-135 9.3290E-01 3.6531E-10 1.6296E+15 1.1523E+15 Xe-135m 4.1457E-03 4.5511E-14 2.0302E+11 2.0890E+14 Xe-138 6.5182E-03 6.7789E-14 2.9582E+11 8.3128E+14 Control Room Transport Group Inventory:

Time (h) = 2.0000 Atmosphere Sump Noble gases (atoms) 9.4552E+17 0.0000E+00 Elemental I (atoms) 2.4747E+14 0.0000E+00 Organic I (atoms) 1.8668E+14 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 4.3058E-12 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 4.9958E-12 Total I (Ci) 4.0242E-02 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 2.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0932E+19 Elemental I (atoms) 0.0000E+00 2.9431E+15 Organic I (atoms) 0.0000E+00 2.2202E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 2.0000 Filtered Transported Noble gases (atoms) 9.9805E+18 0.0000E+00 Elemental I (atoms) 2.6618E+15 0.0000E+00 Organic I (atoms) 2.0080E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.4133E+00 1.3687E+01 2.8411E+00 Low Population Zone Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.6965E-01 1.5293E+00 3.1744E-01 Control Room Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.3191E-02 4.6399E+00 1.5728E-01 Accumulated dose (rem) 3.2652E-01 5.4676E+01 2.0329E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Decay Kr-83m 4.7834E-06 2.3184E-16 1.6822E+09 1.6846E+14

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 112 Kr-85 2.6183E-05 6.6735E-11 4.7281E+14 5.9330E+13 Kr-85m 6.2584E-05 7.6048E-15 5.3879E+10 4.3498E+14 Kr-87 5.5307E-06 1.9525E-16 1.3515E+09 6.8236E+14 Kr-88 8.3356E-05 6.6476E-15 4.5492E+10 1.1130E+15 Br-83 4.7443E-08 3.0032E-18 2.1790E+07 8.8748E+11 I-130 5.6175E-08 2.8803E-17 1.3343E+08 1.9079E+11 I-131 5.2430E-06 4.2290E-14 1.9441E+11 1.2192E+13 I-132 4.4218E-07 4.2838E-17 1.9544E+08 8.9913E+12 I-133 5.3761E-06 4.7458E-15 2.1489E+10 1.5490E+13 I-134 1.4326E-08 5.3704E-19 2.4135E+06 1.1081E+13 I-135 2.8666E-06 8.1625E-16 3.6412E+09 1.3864E+13 Xe-131m 9.2769E-06 1.1075E-13 5.0914E+11 2.1390E+13 Xe-133 1.3429E-03 7.1741E-12 3.2484E+13 3.1617E+15 Xe-133m 3.8760E-05 8.6383E-14 3.9113E+11 9.6552E+13 Xe-135 3.1901E-04 1.2492E-13 5.5725E+11 1.2399E+15 Xe-135m 5.1092E-07 5.6089E-18 2.5020E+07 2.0912E+14 Control Room Transport Group Inventory:

Time (h) = 8.0000 Atmosphere Sump Noble gases (atoms) 5.0685E+14 0.0000E+00 Elemental I (atoms) 1.2534E+11 0.0000E+00 Organic I (atoms) 9.4555E+10 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 2.1760E-15 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 2.4247E-15 Total I (Ci) 1.3942E-05 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 8.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0932E+19 Elemental I (atoms) 0.0000E+00 2.9431E+15 Organic I (atoms) 0.0000E+00 2.2202E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 8.0000 Filtered Transported Noble gases (atoms) 1.0925E+19 0.0000E+00 Elemental I (atoms) 2.9070E+15 0.0000E+00 Organic I (atoms) 2.1930E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.4133E+00 1.3687E+01 2.8411E+00 Low Population Zone Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.6965E-01 1.5293E+00 3.1744E-01 Control Room Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.1886E-06 2.3500E-03 7.4711E-05 Accumulated dose (rem) 3.2652E-01 5.4678E+01 2.0330E+00 Control Room Compartment Nuclide Inventory:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 113 Time (h) = 24.0000 Ci kg Atoms Decay Kr-85 5.0088E-14 1.2767E-19 9.0450E+05 5.9333E+13 Xe-133 2.3588E-12 1.2602E-20 5.7059E+04 3.1618E+15 Control Room Transport Group Inventory:

Time (h) = 24.0000 Atmosphere Sump Noble gases (atoms) 9.6344E+05 0.0000E+00 Elemental I (atoms) 2.1472E+02 0.0000E+00 Organic I (atoms) 1.6198E+02 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 3.6730E-24 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 3.9053E-24 Total I (Ci) 1.6537E-14 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 24.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0932E+19 Elemental I (atoms) 0.0000E+00 2.9431E+15 Organic I (atoms) 0.0000E+00 2.2202E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 24.0000 Filtered Transported Noble gases (atoms) 1.0926E+19 0.0000E+00 Elemental I (atoms) 2.9071E+15 0.0000E+00 Organic I (atoms) 2.1931E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.4133E+00 1.3687E+01 2.8411E+00 Low Population Zone Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.6965E-01 1.5293E+00 3.1744E-01 Control Room Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 7.0351E-16 2.6905E-12 8.3212E-14 Accumulated dose (rem) 3.2652E-01 5.4678E+01 2.0330E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 96.0000 Ci kg Atoms Decay Control Room Transport Group Inventory:

Time (h) = 96.0000 Atmosphere Sump Noble gases (atoms) 5.5307E-34 0.0000E+00 Elemental I (atoms) 9.1305E-38 0.0000E+00 Organic I (atoms) 6.8879E-38 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 1.5170E-63 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 1.5284E-63 Total I (Ci) 4.6066E-54 CR Air Intake Transport Group Inventory:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 114 Pathway Time (h) = 96.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0932E+19 Elemental I (atoms) 0.0000E+00 2.9431E+15 Organic I (atoms) 0.0000E+00 2.2202E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 96.0000 Filtered Transported Noble gases (atoms) 1.0926E+19 0.0000E+00 Elemental I (atoms) 2.9071E+15 0.0000E+00 Organic I (atoms) 2.1931E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.4133E+00 1.3687E+01 2.8411E+00 Low Population Zone Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 2.6965E-01 1.5293E+00 3.1744E-01 Control Room Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.1065E-55 7.4141E-52 2.2702E-53 Accumulated dose (rem) 3.2652E-01 5.4678E+01 2.0330E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 720.0000 Ci kg Atoms Decay Control Room Transport Group Inventory:

Time (h) = 720.0000 Atmosphere Sump Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 0.0000E+00 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 0.0000E+00 Total I (Ci) 0.0000E+00 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 720.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0932E+19 Elemental I (atoms) 0.0000E+00 2.9431E+15 Organic I (atoms) 0.0000E+00 2.2202E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 720.0000 Filtered Transported Noble gases (atoms) 1.0926E+19 0.0000E+00 Elemental I (atoms) 2.9071E+15 0.0000E+00 Organic I (atoms) 2.1931E+15 0.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 115 Aerosols (kg) 0.0000E+00 0.0000E+00 838 I-131 Summary Reactor Building Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 0.000 2.5122E+01 1.6075E-02 5.6387E-05 0.004 1.6222E+02 6.7341E-01 2.3591E-03 0.400 6.5012E+01 9.7709E+01 7.4467E-02 0.700 3.2543E+01 1.3012E+02 5.1078E-02 1.000 1.6290E+01 1.4635E+02 3.5031E-02 1.300 8.1545E+00 1.5447E+02 2.4023E-02 1.600 4.0819E+00 1.5853E+02 1.6473E-02 1.900 2.0433E+00 1.6057E+02 1.1295E-02 2.000 1.6224E+00 1.6099E+02 9.9603E-03 2.300 1.6206E+00 1.6099E+02 6.8287E-03 2.600 1.6189E+00 1.6099E+02 4.6817E-03 2.900 1.6172E+00 1.6099E+02 3.2097E-03 3.200 1.6154E+00 1.6099E+02 2.2006E-03 3.500 1.6137E+00 1.6099E+02 1.5087E-03 3.800 1.6119E+00 1.6099E+02 1.0343E-03 4.100 1.6102E+00 1.6099E+02 7.0913E-04 4.400 1.6085E+00 1.6099E+02 4.8618E-04 4.700 1.6067E+00 1.6099E+02 3.3332E-04 5.000 1.6050E+00 1.6099E+02 2.2852E-04 5.300 1.6033E+00 1.6099E+02 1.5667E-04 5.600 1.6015E+00 1.6099E+02 1.0741E-04 5.900 1.5998E+00 1.6099E+02 7.3641E-05 6.200 1.5981E+00 1.6099E+02 5.0488E-05 6.500 1.5964E+00 1.6099E+02 3.4614E-05 6.800 1.5947E+00 1.6099E+02 2.3731E-05 7.100 1.5929E+00 1.6099E+02 1.6270E-05 7.400 1.5912E+00 1.6099E+02 1.1154E-05 7.700 1.5895E+00 1.6099E+02 7.6473E-06 8.000 1.5878E+00 1.6099E+02 5.2430E-06 8.300 1.5861E+00 1.6099E+02 3.5945E-06 8.600 1.5844E+00 1.6099E+02 2.4644E-06 8.900 1.5827E+00 1.6099E+02 1.6896E-06 9.200 1.5810E+00 1.6099E+02 1.1583E-06 9.500 1.5793E+00 1.6099E+02 7.9415E-07 9.800 1.5776E+00 1.6099E+02 5.4446E-07 10.100 1.5759E+00 1.6099E+02 3.7328E-07 10.400 1.5742E+00 1.6099E+02 2.5592E-07 24.000 1.4991E+00 1.6099E+02 9.4706E-15 96.000 1.1575E+00 1.6099E+02 4.2853E-54 720.000 1.2304E-01 1.6099E+02 0.0000E+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone Control Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 0.000 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.004 5.7438E-02 1.5717E-02 6.4176E-03 1.7561E-03 1.9855E-03 8.2306E-05 0.400 8.3266E+00 1.9968E+00 9.3035E-01 2.2311E-01 1.9476E+01 7.7126E-01 0.700 1.1079E+01 2.4768E+00 1.2379E+00 2.7674E-01 3.0602E+01 1.1851E+00 1.000 1.2453E+01 2.6821E+00 1.3914E+00 2.9967E-01 3.8211E+01 1.4600E+00 1.300 1.3139E+01 2.7744E+00 1.4680E+00 3.0999E-01 4.3415E+01 1.6448E+00 1.600 1.3481E+01 2.8171E+00 1.5063E+00 3.1476E-01 4.6975E+01 1.7695E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 116 1.900 1.3652E+01 2.8371E+00 1.5254E+00 3.1700E-01 4.9409E+01 1.8540E+00 2.000 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.0036E+01 1.8756E+00 2.300 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.1503E+01 1.9260E+00 2.600 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.2506E+01 1.9602E+00 2.900 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.3192E+01 1.9834E+00 3.200 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.3661E+01 1.9992E+00 3.500 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.3983E+01 2.0100E+00 3.800 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4202E+01 2.0173E+00 4.100 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4352E+01 2.0223E+00 4.400 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4455E+01 2.0257E+00 4.700 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4526E+01 2.0280E+00 5.000 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4574E+01 2.0296E+00 5.300 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4607E+01 2.0307E+00 5.600 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4629E+01 2.0314E+00 5.900 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4645E+01 2.0319E+00 6.200 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4655E+01 2.0322E+00 6.500 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4662E+01 2.0325E+00 6.800 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4667E+01 2.0326E+00 7.100 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4671E+01 2.0327E+00 7.400 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4673E+01 2.0328E+00 7.700 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4674E+01 2.0329E+00 8.000 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4676E+01 2.0329E+00 8.300 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4676E+01 2.0329E+00 8.600 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4677E+01 2.0329E+00 8.900 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4677E+01 2.0329E+00 9.200 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4677E+01 2.0330E+00 9.500 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4678E+01 2.0330E+00 9.800 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4678E+01 2.0330E+00 10.100 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4678E+01 2.0330E+00 10.400 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4678E+01 2.0330E+00 24.000 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4678E+01 2.0330E+00 96.000 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4678E+01 2.0330E+00 720.000 1.3687E+01 2.8411E+00 1.5293E+00 3.1744E-01 5.4678E+01 2.0330E+00 Worst Two-Hour Doses Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 0.0 2.4133E+00 1.3687E+01 2.8411E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 117 NF-500_GNF2_24-104_CREVAS.o0 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:39:03 File information Plant file = D:\\Staum\\Fitz\\FHA\\24-104 hr\\NF-500_GNF2_24-104_CREVAS.psf Inventory file = d:\\staum\\fitz\\fha\\jfha_source_24.nif Release file = d:\\staum\\fitz\\fha\\jafha_rft_with_df.rft Dose Conversion file = d:\\staum\\fitz\\fha\\jafha_fg11&12.inp Radtrad 3.03 4/15/2001 JAF FHA Occurring In Reactor Bldg With RB Vent Release, Pool DF = 200, Peaking Factor =

1.82, Decay Time = 96 Hrs, CR Normal Flow Rate =2,112 cfm, No SGTS Filtration, and Plant Vent Release @ 99,800 cfm Nuclide Inventory File:

d:\\staum\\fitz\\fha\\jfha_source_24.nif Plant Power Level:

1.5780E+01 Compartments:

3 Compartment 1:

Reactor Building 3

2.6000E+06 0

0 0

0 0

Compartment 2:

Environment 2

0.0000E+00 0

0 0

0 0

Compartment 3:

Control Room 1

1.0100E+05 0

0 0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 118 0

0 Pathways:

4 Pathway 1:

Reactor Building to Environment 1

2 2

Pathway 2:

CR Air Intake - UnFiltered 2

3 2

Pathway 3:

CR Air Intake - Filtered 2

3 2

Pathway 4:

CR Exhaust to Environment 3

2 2

End of Plant Model File Scenario Description Name:

Plant Model Filename:

Source Term:

1 1 1.0000E+00 d:\\staum\\fitz\\fha\\jafha_fg11&12.inp d:\\staum\\fitz\\fha\\jafha_rft_with_df.rft 0.0000E+00 1

0.0000E+00 5.7000E-01 4.3000E-01 1.0000E+00 Overlying Pool:

0 0.0000E+00 0

0 0

0 Compartments:

3 Compartment 1:

0 1

0 0

0 0

0 0

0 Compartment 2:

0 1

0 0

0 0

0 0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 119 0

Compartment 3:

1 1

0 0

0 0

0 0

0 Pathways:

4 Pathway 1:

0 0

0 0

0 1

3 0.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 2.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 2:

0 0

0 0

0 1

2 0.0000E+00 4.0000E+02 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 3:

0 0

0 0

0 1

3 0.0000E+00 1.7120E+03 0.0000E+00 0.0000E+00 0.0000E+00 1.3333E-01 9.0000E+02 9.7000E+01 9.7000E+01 9.7000E+01 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 4:

0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 120 0

0 0

0 1

3 0.0000E+00 2.1120E+03 1.0000E+02 1.0000E+02 1.0000E+02 1.3333E-01 1.3000E+03 1.0000E+02 1.0000E+02 1.0000E+02 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Dose Locations:

3 Location 1:

Exclusion Area Boundary 2

1 2

0.0000E+00 1.7900E-04 7.2000E+02 0.0000E+00 1

2 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 0

Location 2:

Low Population Zone 2

1 5

0.0000E+00 2.0000E-05 8.0000E+00 1.3400E-05 2.4000E+01 5.5900E-06 9.6000E+01 1.6000E-06 7.2000E+02 0.0000E+00 1

4 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 0.0000E+00 0

Location 3:

Control Room 3

0 1

2 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 1

4 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 0.0000E+00 Effective Volume Location:

1 6

0.0000E+00 3.5200E-03 2.0000E+00 3.3100E-03

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 121 8.0000E+00 1.4300E-03 2.4000E+01 7.7300E-04 9.6000E+01 6.0700E-04 7.2000E+02 0.0000E+00 Simulation Parameters:

6 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.0000E+00 7.2000E+02 0.0000E+00 Output Filename:

D:\\Staum\\Fitz\\FHA\\24-120\\NF-500_GNF2_24_CREVAS.o0 1

1 1

0 0

End of Scenario File RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:39:03 Plant Description Number of Nuclides = 60 Inventory Power = 1.0000E+00 MWth Plant Power Level = 1.5780E+01 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.0000E+00

)

Name: Reactor Building Compartment volume = 2.6000E+06 (Cubic feet)

Compartment type is Normal Pathways into and out of compartment 1 Exit Pathway Number 1: Reactor Building to Environment Compartment number 2 Name: Environment Compartment type is Environment Pathways into and out of compartment 2 Inlet Pathway Number 1: Reactor Building to Environment Inlet Pathway Number 4: CR Exhaust to Environment Exit Pathway Number 2: CR Air Intake - UnFiltered Exit Pathway Number 3: CR Air Intake - Filtered Compartment number 3 Name: Control Room Compartment volume = 1.0100E+05 (Cubic feet)

Compartment type is Control Room Pathways into and out of compartment 3 Inlet Pathway Number 2: CR Air Intake - UnFiltered Inlet Pathway Number 3: CR Air Intake - Filtered Exit Pathway Number 4: CR Exhaust to Environment

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 122 Total number of pathways = 4 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:39:03 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled Release Fractions and Timings GAP EARLY IN-VESSEL LATE RELEASE RELEASE MASS 0.003600 hr 0.0000 hrs 0.0000 hrs (gm)

NOBLES 5.0000E-02 0.0000E+00 0.0000E+00 2.355E+00 IODINE 2.5000E-04 0.0000E+00 0.0000E+00 1.439E-03 CESIUM 1.2000E-01 0.0000E+00 0.0000E+00 0.000E+00 TELLURIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 STRONTIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 BARIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 RUTHENIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 CERIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 LANTHANUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 Inventory Power = 16. MWt Nuclide Group Specific half Whole Body Inhaled Inhaled Name Inventory life DCF Thyroid Effective (Ci/MWt) (s) (Sv-m3/Bq-s) (Sv/Bq) (Sv/Bq)

Kr-83m 1 1.580E+01 6.588E+03 1.500E-18 0.000E+00 0.000E+00 Kr-85 1 1.052E+03 3.383E+08 1.190E-16 0.000E+00 0.000E+00 Kr-85m 1 2.140E+02 1.613E+04 7.480E-15 0.000E+00 0.000E+00 Kr-87 1 3.680E-02 4.578E+03 4.120E-14 0.000E+00 0.000E+00 Kr-88 1 6.740E+01 1.022E+04 1.020E-13 0.000E+00 0.000E+00 Br-83 2 4.120E+00 8.604E+03 3.820E-16 3.290E-12 2.330E-11 Br-84 2 1.900E-10 1.908E+03 9.410E-14 3.120E-12 2.610E-11 I-130 2 1.850E+02 4.450E+04 1.040E-13 1.990E-08 7.140E-10 I-131 2 4.048E+04 6.947E+05 1.820E-14 2.920E-07 8.890E-09 I-132 2 3.220E+04 8.280E+03 1.120E-13 1.740E-09 1.030E-10 I-133 2 2.610E+04 7.488E+04 2.940E-14 4.860E-08 1.580E-09 I-134 2 1.560E-03 3.156E+03 1.300E-13 2.880E-10 3.550E-11 I-135 2 4.240E+04 2.380E+04 8.294E-14 8.460E-09 3.320E-10 Xe-131m 1 3.750E+02 1.028E+06 3.890E-16 0.000E+00 0.000E+00 Xe-133 1 5.430E+04 4.532E+05 1.560E-15 0.000E+00 0.000E+00 Xe-133m 1 1.550E+03 1.890E+05 1.370E-15 0.000E+00 0.000E+00 Xe-135 1 1.500E+04 3.272E+04 1.190E-14 0.000E+00 0.000E+00 Xe-135m 1 6.920E+02 9.174E+02 2.040E-14 0.000E+00 0.000E+00 Xe-138 1 8.190E-27 8.502E+02 5.770E-14 0.000E+00 0.000E+00 Nuclide Daughter Fraction Daughter Fraction Daughter Fraction Kr-85m Kr-85 0.21 none 0.00 none 0.00 Kr-87 Rb-87 1.00 none 0.00 none 0.00 Kr-88 Rb-88 1.00 none 0.00 none 0.00 Br-83 Kr-83m 1.00 none 0.00 none 0.00 I-131 Xe-131m 0.01 none 0.00 none 0.00 I-133 Xe-133m 0.03 Xe-133 0.97 none 0.00 I-135 Xe-135m 0.15 Xe-135 0.85 none 0.00 Xe-133m Xe-133 1.00 none 0.00 none 0.00 Xe-135 Cs-135 1.00 none 0.00 none 0.00 Xe-135m Xe-135 1.00 none 0.00 none 0.00 Xe-138 Cs-138 1.00 none 0.00 none 0.00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 123 Iodine fractions Aerosol = 0.0000E+00 Elemental = 5.7000E-01 Organic = 4.3000E-01 COMPARTMENT DATA Compartment number 1: Reactor Building Compartment number 2: Environment Compartment number 3: Control Room PATHWAY DATA Pathway number 1: Reactor Building to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 2.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 2: CR Air Intake - UnFiltered Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 4.0000E+02 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 3: CR Air Intake - Filtered Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 1.7120E+03 0.0000E+00 0.0000E+00 0.0000E+00 1.3333E-01 9.0000E+02 9.7000E+01 9.7000E+01 9.7000E+01 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 4: CR Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 2.1120E+03 1.0000E+02 1.0000E+02 1.0000E+02 1.3333E-01 1.3000E+03 1.0000E+02 1.0000E+02 1.0000E+02 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s

  • m^-3) 0.0000E+00 1.7900E-04 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 124 7.2000E+02 0.0000E+00 Location Low Population Zone is in compartment 2 Location X/Q Data Time (hr) X/Q (s

  • m^-3) 0.0000E+00 2.0000E-05 8.0000E+00 1.3400E-05 2.4000E+01 5.5900E-06 9.6000E+01 1.6000E-06 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 0.0000E+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 0.0000E+00 3.5200E-03 2.0000E+00 3.3100E-03 8.0000E+00 1.4300E-03 2.4000E+01 7.7300E-04 9.6000E+01 6.0700E-04 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 Location Occupancy Factor Data Time (hr) Occupancy Factor 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 0.0000E+00 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.0000E+00 7.2000E+02 0.0000E+00 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:39:03

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 125 Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 7.1640E-04 5.1063E-02 2.2990E-03 Accumulated dose (rem) 7.1640E-04 5.1063E-02 2.2990E-03 Low Population Zone Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 8.0045E-05 5.7054E-03 2.5687E-04 Accumulated dose (rem) 8.0045E-05 5.7054E-03 2.5687E-04 Control Room Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 1.0374E-06 1.7651E-03 5.5744E-05 Accumulated dose (rem) 1.0374E-06 1.7651E-03 5.5744E-05 Control Room Compartment Nuclide Inventory:

Time (h) = 0.0036 Ci kg Atoms Decay Kr-83m 1.8031E-04 8.7395E-15 6.3410E+10 6.1401E+07 Kr-85 1.2021E-02 3.0640E-08 2.1708E+17 4.0915E+09 Kr-85m 2.4440E-03 2.9698E-13 2.1041E+12 8.3201E+08 Kr-87 4.1969E-07 1.4817E-17 1.0256E+08 1.4295E+05 Kr-88 7.6951E-04 6.1368E-14 4.1996E+11 2.6199E+08 Br-83 2.3515E-07 1.4885E-17 1.0800E+08 8.0066E+04 I-130 1.0568E-05 5.4185E-15 2.5101E+10 3.5971E+06 I-131 2.3128E-03 1.8655E-11 8.5760E+13 7.8719E+08 I-132 1.8378E-03 1.7804E-13 8.1226E+11 6.2574E+08 I-133 1.4911E-03 1.3162E-12 5.9598E+12 5.0751E+08 I-134 8.8878E-11 3.3317E-21 1.4973E+04 3.0281E+01 I-135 2.4216E-03 6.8956E-13 3.0760E+12 8.2433E+08 Xe-131m 4.2851E-03 5.1159E-11 2.3518E+14 1.4585E+09 Xe-133 6.2048E-01 3.3148E-09 1.5009E+16 2.1119E+11 Xe-133m 1.7711E-02 3.9472E-11 1.7872E+14 6.0283E+09 Xe-135 1.7138E-01 6.7111E-11 2.9937E+14 5.8336E+10 Xe-135m 7.9635E-03 8.7422E-14 3.8998E+11 2.7182E+09 Control Room Transport Group Inventory:

Time (h) = 0.0036 Atmosphere Sump Noble gases (atoms) 2.3281E+17 0.0000E+00 Elemental I (atoms) 5.4511E+13 0.0000E+00 Organic I (atoms) 4.1122E+13 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 9.2381E-13 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 1.0416E-12 Total I (Ci) 8.0632E-03 CR Air Intake - UnFiltered Transport Group Inventory:

Pathway Time (h) = 0.0036 Filtered Transported Noble gases (atoms) 0.0000E+00 4.4159E+16 Elemental I (atoms) 0.0000E+00 1.0340E+13 Organic I (atoms) 0.0000E+00 7.8003E+12 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Air Intake - Filtered Transport Group Inventory:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 126 Pathway Time (h) = 0.0036 Filtered Transported Noble gases (atoms) 0.0000E+00 1.8900E+17 Elemental I (atoms) 0.0000E+00 4.4255E+13 Organic I (atoms) 0.0000E+00 3.3385E+13 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 0.0036 Filtered Transported Noble gases (atoms) 3.5080E+14 0.0000E+00 Elemental I (atoms) 8.2141E+10 0.0000E+00 Organic I (atoms) 6.1966E+10 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 0.1333 Whole Body Thyroid TEDE Delta dose (rem) 4.4398E-02 3.1761E+00 1.4283E-01 Accumulated dose (rem) 4.5114E-02 3.2272E+00 1.4513E-01 Low Population Zone Doses:

Time (h) = 0.1333 Whole Body Thyroid TEDE Delta dose (rem) 4.9606E-03 3.5488E-01 1.5959E-02 Accumulated dose (rem) 5.0407E-03 3.6058E-01 1.6216E-02 Control Room Doses:

Time (h) = 0.1333 Whole Body Thyroid TEDE Delta dose (rem) 2.9379E-03 5.0324E+00 1.5890E-01 Accumulated dose (rem) 2.9390E-03 5.0342E+00 1.5895E-01 Control Room Compartment Nuclide Inventory:

Time (h) = 0.1333 Ci kg Atoms Decay Kr-83m 9.9783E-03 4.8363E-13 3.5090E+12 1.4929E+11 Kr-85 6.9868E-01 1.7808E-06 1.2617E+19 1.0211E+13 Kr-85m 1.3923E-01 1.6918E-11 1.1986E+14 2.0543E+12 Kr-87 2.2727E-05 8.0236E-16 5.5540E+09 3.4360E+08 Kr-88 4.3330E-02 3.4556E-12 2.3648E+13 6.4289E+11 Br-83 1.3163E-05 8.3319E-16 6.0453E+09 1.9585E+08 I-130 6.0976E-04 3.1264E-13 1.4483E+12 8.9421E+09 I-131 1.3436E-01 1.0838E-09 4.9821E+15 1.9640E+12 I-132 1.0272E-01 9.9511E-12 4.5399E+13 1.5294E+12 I-133 8.6287E-02 7.6171E-11 3.4490E+14 1.2636E+12 I-134 4.6621E-09 1.7476E-19 7.8540E+05 7.1578E+04 I-135 1.3884E-01 3.9536E-11 1.7636E+14 2.0423E+12 Xe-131m 2.4898E-01 2.9725E-09 1.3665E+16 3.6391E+12 Xe-133 3.6038E+01 1.9253E-07 8.7175E+17 5.2683E+14 Xe-133m 1.0276E+00 2.2902E-09 1.0370E+16 1.5030E+13 Xe-135 9.8682E+00 3.8642E-09 1.7238E+16 1.4484E+14 Xe-135m 3.3365E-01 3.6628E-12 1.6339E+13 5.7035E+12 Control Room Transport Group Inventory:

Time (h) = 0.1333 Atmosphere Sump Noble gases (atoms) 1.3530E+19 0.0000E+00 Elemental I (atoms) 3.1636E+15 0.0000E+00 Organic I (atoms) 2.3866E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 5.3621E-11 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 6.0376E-11 Total I (Ci) 4.6221E-01

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 127 CR Air Intake - UnFiltered Transport Group Inventory:

Pathway Time (h) = 0.1333 Filtered Transported Noble gases (atoms) 0.0000E+00 2.7915E+18 Elemental I (atoms) 0.0000E+00 6.5347E+14 Organic I (atoms) 0.0000E+00 4.9297E+14 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Air Intake - Filtered Transport Group Inventory:

Pathway Time (h) = 0.1333 Filtered Transported Noble gases (atoms) 0.0000E+00 1.1948E+19 Elemental I (atoms) 0.0000E+00 2.7969E+15 Organic I (atoms) 0.0000E+00 2.1099E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 0.1333 Filtered Transported Noble gases (atoms) 1.2102E+18 0.0000E+00 Elemental I (atoms) 2.8324E+14 0.0000E+00 Organic I (atoms) 2.1367E+14 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.1888E-01 8.9550E+00 3.9617E-01 Accumulated dose (rem) 1.6399E-01 1.2182E+01 5.4130E-01 Low Population Zone Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.3282E-02 1.0006E+00 4.4265E-02 Accumulated dose (rem) 1.8323E-02 1.3611E+00 6.0481E-02 Control Room Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 9.5308E-02 1.0962E+02 3.4876E+00 Accumulated dose (rem) 9.8247E-02 1.1466E+02 3.6465E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Decay Kr-83m 4.2947E-03 2.0816E-13 1.5103E+12 2.6761E+12 Kr-85 6.0944E-01 1.5534E-06 1.1005E+19 2.4966E+14 Kr-85m 9.0980E-02 1.1055E-11 7.8326E+13 4.4033E+13 Kr-87 7.1669E-06 2.5302E-16 1.7514E+09 5.4372E+09 Kr-88 2.3966E-02 1.9113E-12 1.3079E+13 1.2810E+13 Br-83 3.4115E-06 2.1595E-16 1.5668E+09 2.2872E+09 I-130 2.4458E-04 1.2540E-13 5.8091E+11 1.2431E+11 I-131 5.9439E-02 4.7944E-10 2.2040E+15 2.8451E+13 I-132 2.6064E-02 2.5251E-12 1.1520E+13 1.7718E+13 I-133 3.6112E-02 3.1878E-11 1.4434E+14 1.7881E+13 I-134 4.7459E-10 1.7790E-20 7.9952E+04 6.0459E+05 I-135 5.0843E-02 1.4478E-11 6.4582E+13 2.7343E+13 Xe-131m 2.1620E-01 2.5811E-09 1.1866E+16 8.8792E+13 Xe-133 3.1123E+01 1.6627E-07 7.5287E+17 1.2822E+16 Xe-133m 8.7460E-01 1.9492E-09 8.8257E+15 3.6331E+14 Xe-135 7.4822E+00 2.9299E-09 1.3070E+16 3.3215E+15 Xe-135m 1.1311E-02 1.2417E-13 5.5390E+11 3.3503E+13

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 128 Control Room Transport Group Inventory:

Time (h) = 2.0000 Atmosphere Sump Noble gases (atoms) 1.1792E+19 0.0000E+00 Elemental I (atoms) 1.3823E+15 0.0000E+00 Organic I (atoms) 1.0428E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 2.3454E-11 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 2.5965E-11 Total I (Ci) 1.7246E-01 CR Air Intake - UnFiltered Transport Group Inventory:

Pathway Time (h) = 2.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0573E+19 Elemental I (atoms) 0.0000E+00 2.4661E+15 Organic I (atoms) 0.0000E+00 1.8604E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Air Intake - Filtered Transport Group Inventory:

Pathway Time (h) = 2.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 2.9455E+19 Elemental I (atoms) 3.9561E+15 2.9192E+15 Organic I (atoms) 2.9844E+15 2.2022E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 2.0000 Filtered Transported Noble gases (atoms) 2.8223E+19 0.0000E+00 Elemental I (atoms) 3.9514E+15 0.0000E+00 Organic I (atoms) 2.9809E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.6399E-01 1.2182E+01 5.4130E-01 Low Population Zone Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.8323E-02 1.3611E+00 6.0481E-02 Control Room Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.5526E-02 4.0552E+01 1.2865E+00 Accumulated dose (rem) 1.3377E-01 1.5521E+02 4.9330E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Decay Kr-83m 4.3115E-06 2.0897E-16 1.5162E+09 3.1537E+12 Kr-85 5.9230E-03 1.5097E-08 1.0696E+17 3.4978E+14 Kr-85m 3.4947E-04 4.2465E-14 3.0086E+11 5.6558E+13 Kr-87 2.6462E-09 9.3422E-20 6.4667E+05 6.1337E+09 Kr-88 5.3856E-05 4.2950E-15 2.9392E+10 1.5824E+13 Br-83 5.8190E-09 3.6834E-19 2.6726E+06 2.6979E+09

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 129 I-130 1.6979E-06 8.7056E-16 4.0328E+09 1.6187E+11 I-131 5.6538E-04 4.5604E-12 2.0964E+13 3.8173E+13 I-132 4.1531E-05 4.0235E-15 1.8356E+10 2.0823E+13 I-133 2.8737E-04 2.5368E-13 1.1486E+12 2.3578E+13 I-135 2.6340E-04 7.5002E-14 3.3457E+11 3.4730E+13 Xe-131m 2.0710E-03 2.4725E-11 1.1366E+14 1.2421E+14 Xe-133 2.9293E-01 1.5650E-09 7.0861E+15 1.7901E+16 Xe-133m 7.8538E-03 1.7503E-11 7.9253E+13 5.0469E+14 Xe-135 4.6154E-02 1.8073E-11 8.0622E+13 4.4449E+15 Xe-135m 4.6947E-05 5.1538E-16 2.2990E+09 3.4744E+13 Control Room Transport Group Inventory:

Time (h) = 8.0000 Atmosphere Sump Noble gases (atoms) 1.1432E+17 0.0000E+00 Elemental I (atoms) 1.2808E+13 0.0000E+00 Organic I (atoms) 9.6621E+12 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 2.1716E-13 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 2.3273E-13 Total I (Ci) 1.1577E-03 CR Air Intake - UnFiltered Transport Group Inventory:

Pathway Time (h) = 8.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0573E+19 Elemental I (atoms) 0.0000E+00 2.4661E+15 Organic I (atoms) 0.0000E+00 1.8604E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Air Intake - Filtered Transport Group Inventory:

Pathway Time (h) = 8.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 2.9455E+19 Elemental I (atoms) 3.9561E+15 2.9192E+15 Organic I (atoms) 2.9844E+15 2.2022E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 8.0000 Filtered Transported Noble gases (atoms) 3.9894E+19 0.0000E+00 Elemental I (atoms) 5.3061E+15 0.0000E+00 Organic I (atoms) 4.0028E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.6399E-01 1.2182E+01 5.4130E-01 Low Population Zone Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.8323E-02 1.3611E+00 6.0481E-02 Control Room Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.5726E-04 3.8016E-01 1.1930E-02 Accumulated dose (rem) 1.3403E-01 1.5559E+02 4.9450E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 130 Control Room Compartment Nuclide Inventory:

Time (h) = 24.0000 Ci kg Atoms Decay Kr-85 2.5477E-08 6.4938E-14 4.6008E+11 3.5076E+14 Kr-85m 1.2646E-10 1.5367E-20 1.0887E+05 5.6607E+13 I-131 2.2964E-09 1.8523E-17 8.5151E+07 3.8266E+13 I-133 7.2534E-10 6.4030E-19 2.8992E+06 2.3624E+13 I-135 2.1165E-10 6.0266E-20 2.6884E+05 3.4769E+13 Xe-131m 8.5710E-09 1.0233E-16 4.7040E+08 1.2455E+14 Xe-133 1.1566E-06 6.1788E-15 2.7977E+10 1.7949E+16 Xe-133m 2.7360E-08 6.0974E-17 2.7609E+08 5.0596E+14 Xe-135 5.8954E-08 2.3086E-17 1.0298E+08 4.4519E+15 Control Room Transport Group Inventory:

Time (h) = 24.0000 Atmosphere Sump Noble gases (atoms) 4.8890E+11 0.0000E+00 Elemental I (atoms) 5.0346E+07 0.0000E+00 Organic I (atoms) 3.7981E+07 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 8.4729E-19 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 8.7690E-19 Total I (Ci) 3.2348E-09 CR Air Intake - UnFiltered Transport Group Inventory:

Pathway Time (h) = 24.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0573E+19 Elemental I (atoms) 0.0000E+00 2.4661E+15 Organic I (atoms) 0.0000E+00 1.8604E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Air Intake - Filtered Transport Group Inventory:

Pathway Time (h) = 24.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 2.9455E+19 Elemental I (atoms) 3.9561E+15 2.9192E+15 Organic I (atoms) 2.9844E+15 2.2022E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 24.0000 Filtered Transported Noble gases (atoms) 4.0009E+19 0.0000E+00 Elemental I (atoms) 5.3188E+15 0.0000E+00 Organic I (atoms) 4.0124E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.6399E-01 1.2182E+01 5.4130E-01 Low Population Zone Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.8323E-02 1.3611E+00 6.0481E-02 Control Room Doses:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 131 Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.1059E-10 9.3609E-07 2.9024E-08 Accumulated dose (rem) 1.3403E-01 1.5559E+02 4.9450E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 96.0000 Ci kg Atoms Decay Control Room Transport Group Inventory:

Time (h) = 96.0000 Atmosphere Sump Noble gases (atoms) 3.4049E-13 0.0000E+00 Elemental I (atoms) 2.6729E-17 0.0000E+00 Organic I (atoms) 2.0164E-17 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 4.4313E-43 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 4.4479E-43 Total I (Ci) 1.3064E-33 CR Air Intake - UnFiltered Transport Group Inventory:

Pathway Time (h) = 96.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0573E+19 Elemental I (atoms) 0.0000E+00 2.4661E+15 Organic I (atoms) 0.0000E+00 1.8604E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Air Intake - Filtered Transport Group Inventory:

Pathway Time (h) = 96.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 2.9455E+19 Elemental I (atoms) 3.9561E+15 2.9192E+15 Organic I (atoms) 2.9844E+15 2.2022E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 96.0000 Filtered Transported Noble gases (atoms) 4.0009E+19 0.0000E+00 Elemental I (atoms) 5.3188E+15 0.0000E+00 Organic I (atoms) 4.0124E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.6399E-01 1.2182E+01 5.4130E-01 Low Population Zone Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.8323E-02 1.3611E+00 6.0481E-02 Control Room Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 9.5957E-35 3.2677E-31 1.0049E-32 Accumulated dose (rem) 1.3403E-01 1.5559E+02 4.9450E+00 Control Room Compartment Nuclide Inventory:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 132 Time (h) = 720.0000 Ci kg Atoms Decay Control Room Transport Group Inventory:

Time (h) = 720.0000 Atmosphere Sump Noble gases (atoms) 1.6820-222 0.0000E+00 Elemental I (atoms) 1.4616-227 0.0000E+00 Organic I (atoms) 1.1026-227 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 2.4178-253 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 2.4178-253 Total I (Ci) 6.9150-244 CR Air Intake - UnFiltered Transport Group Inventory:

Pathway Time (h) = 720.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0573E+19 Elemental I (atoms) 0.0000E+00 2.4661E+15 Organic I (atoms) 0.0000E+00 1.8604E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Air Intake - Filtered Transport Group Inventory:

Pathway Time (h) = 720.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 2.9455E+19 Elemental I (atoms) 3.9561E+15 2.9192E+15 Organic I (atoms) 2.9844E+15 2.2022E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 720.0000 Filtered Transported Noble gases (atoms) 4.0009E+19 0.0000E+00 Elemental I (atoms) 5.3188E+15 0.0000E+00 Organic I (atoms) 4.0124E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 839 I-131 Summary Reactor Building Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 0.000 2.4628E+01 1.5759E-02 5.5279E-05 0.004 1.5903E+02 6.6018E-01 2.3128E-03 0.133 1.1790E+02 4.1719E+01 1.3436E-01 0.500 5.0606E+01 1.0890E+02 1.4176E-01 0.800 2.5332E+01 1.3413E+02 1.2808E-01 1.100 1.2681E+01 1.4676E+02 1.0937E-01 1.400 6.3475E+00 1.5308E+02 9.0607E-02 1.700 3.1774E+00 1.5624E+02 7.3768E-02 2.000 1.5905E+00 1.5783E+02 5.9439E-02 2.300 1.5888E+00 1.5783E+02 4.7096E-02 2.600 1.5871E+00 1.5783E+02 3.7316E-02 2.900 1.5854E+00 1.5783E+02 2.9567E-02 3.200 1.5837E+00 1.5783E+02 2.3427E-02 3.500 1.5820E+00 1.5783E+02 1.8563E-02 3.800 1.5803E+00 1.5783E+02 1.4708E-02 4.100 1.5786E+00 1.5783E+02 1.1654E-02 4.400 1.5769E+00 1.5783E+02 9.2337E-03 4.700 1.5752E+00 1.5783E+02 7.3163E-03

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 133 5.000 1.5735E+00 1.5783E+02 5.7970E-03 5.300 1.5718E+00 1.5783E+02 4.5932E-03 5.600 1.5701E+00 1.5783E+02 3.6394E-03 5.900 1.5684E+00 1.5783E+02 2.8837E-03 6.200 1.5667E+00 1.5783E+02 2.2848E-03 6.500 1.5650E+00 1.5783E+02 1.8104E-03 6.800 1.5633E+00 1.5783E+02 1.4344E-03 7.100 1.5617E+00 1.5783E+02 1.1366E-03 7.400 1.5600E+00 1.5783E+02 9.0056E-04 7.700 1.5583E+00 1.5783E+02 7.1355E-04 8.000 1.5566E+00 1.5783E+02 5.6538E-04 8.300 1.5549E+00 1.5783E+02 4.4797E-04 8.600 1.5533E+00 1.5783E+02 3.5495E-04 8.900 1.5516E+00 1.5783E+02 2.8124E-04 9.200 1.5499E+00 1.5783E+02 2.2284E-04 9.500 1.5483E+00 1.5783E+02 1.7656E-04 9.800 1.5466E+00 1.5783E+02 1.3990E-04 10.100 1.5449E+00 1.5783E+02 1.1085E-04 10.400 1.5433E+00 1.5783E+02 8.7830E-05 24.000 1.4697E+00 1.5783E+02 2.2964E-09 96.000 1.1347E+00 1.5783E+02 1.2596E-33 720.000 1.2062E-01 1.5783E+02 6.9150-244 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone Control Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 0.000 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.004 5.1063E-02 2.2990E-03 5.7054E-03 2.5687E-04 1.7651E-03 5.5744E-05 0.133 3.2272E+00 1.4513E-01 3.6058E-01 1.6216E-02 5.0342E+00 1.5895E-01 0.500 8.4166E+00 3.7627E-01 9.4040E-01 4.2041E-02 3.3171E+01 1.0514E+00 0.800 1.0361E+01 4.6197E-01 1.1577E+00 5.1617E-02 5.5213E+01 1.7530E+00 1.100 1.1333E+01 5.0448E-01 1.2662E+00 5.6367E-02 7.4498E+01 2.3675E+00 1.400 1.1818E+01 5.2560E-01 1.3205E+00 5.8726E-02 9.0678E+01 2.8830E+00 1.700 1.2061E+01 5.3609E-01 1.3476E+00 5.9898E-02 1.0394E+02 3.3053E+00 2.000 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.1466E+02 3.6465E+00 2.300 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.2320E+02 3.9184E+00 2.600 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.2997E+02 4.1334E+00 2.900 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.3532E+02 4.3033E+00 3.200 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.3955E+02 4.4376E+00 3.500 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.4290E+02 4.5437E+00 3.800 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.4555E+02 4.6277E+00 4.100 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.4764E+02 4.6940E+00 4.400 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.4930E+02 4.7465E+00 4.700 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5061E+02 4.7880E+00 5.000 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5165E+02 4.8208E+00 5.300 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5247E+02 4.8468E+00 5.600 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5312E+02 4.8673E+00 5.900 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5364E+02 4.8835E+00 6.200 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5404E+02 4.8964E+00 6.500 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5437E+02 4.9065E+00 6.800 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5462E+02 4.9145E+00 7.100 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5482E+02 4.9209E+00 7.400 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5498E+02 4.9259E+00 7.700 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5511E+02 4.9299E+00 8.000 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5521E+02 4.9330E+00 8.300 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5529E+02 4.9355E+00 8.600 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5535E+02 4.9375E+00 8.900 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5540E+02 4.9391E+00 9.200 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5544E+02 4.9403E+00 9.500 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5547E+02 4.9413E+00 9.800 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5549E+02 4.9420E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 134 10.100 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5551E+02 4.9426E+00 10.400 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5553E+02 4.9431E+00 24.000 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5559E+02 4.9450E+00 96.000 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5559E+02 4.9450E+00 720.000 1.2182E+01 5.4130E-01 1.3611E+00 6.0481E-02 1.5559E+02 4.9450E+00 Worst Two-Hour Doses Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 0.0 1.6399E-01 1.2182E+01 5.4130E-01

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 135 NF-500_GNF3_24-104_CREVAS.o0 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:39:18 File information Plant file = D:\\Staum\\Fitz\\FHA\\24-104 hr\\NF-500_GNF3_24-104_CREVAS.psf Inventory file = d:\\staum\\fitz\\fha\\jfha_source_24.nif Release file = d:\\staum\\fitz\\fha\\jafha_rft_with_df.rft Dose Conversion file = d:\\staum\\fitz\\fha\\jafha_fg11&12.inp Radtrad 3.03 4/15/2001 JAF FHA Occurring In Reactor Bldg With RB Vent Release, Pool DF = 200, Peaking Factor =

1.82, Decay Time = 96 Hrs, CR Normal Flow Rate =2,112 cfm, No SGTS Filtration, and Plant Vent Release @ 99,800 cfm Nuclide Inventory File:

d:\\staum\\fitz\\fha\\jfha_source_24.nif Plant Power Level:

1.5027E+01 Compartments:

3 Compartment 1:

Reactor Building 3

2.6000E+06 0

0 0

0 0

Compartment 2:

Environment 2

0.0000E+00 0

0 0

0 0

Compartment 3:

Control Room 1

1.0100E+05 0

0 0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 136 0

0 Pathways:

4 Pathway 1:

Reactor Building to Environment 1

2 2

Pathway 2:

CR Air Intake - UnFilter 2

3 2

Pathway 3:

CR Air Intake - Filter 2

3 2

Pathway 4:

CR Exhaust to Environment 3

2 2

End of Plant Model File Scenario Description Name:

Plant Model Filename:

Source Term:

1 1 1.0000E+00 d:\\staum\\fitz\\fha\\jafha_fg11&12.inp d:\\staum\\fitz\\fha\\jafha_rft_with_df.rft 0.0000E+00 1

0.0000E+00 5.7000E-01 4.3000E-01 1.0000E+00 Overlying Pool:

0 0.0000E+00 0

0 0

0 Compartments:

3 Compartment 1:

0 1

0 0

0 0

0 0

0 Compartment 2:

0 1

0 0

0 0

0 0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 137 0

Compartment 3:

1 1

0 0

0 0

0 0

0 Pathways:

4 Pathway 1:

0 0

0 0

0 1

3 0.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 2.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 2:

0 0

0 0

0 1

2 0.0000E+00 4.0000E+02 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 3:

0 0

0 0

0 1

3 0.0000E+00 1.7120E+03 0.0000E+00 0.0000E+00 0.0000E+00 1.3333E-01 9.0000E+02 9.7000E+01 9.7000E+01 9.7000E+01 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 4:

0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 138 0

0 0

0 1

3 0.0000E+00 2.1120E+03 1.0000E+02 1.0000E+02 1.0000E+02 1.3333E-01 1.3000E+03 1.0000E+02 1.0000E+02 1.0000E+02 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Dose Locations:

3 Location 1:

Exclusion Area Boundary 2

1 2

0.0000E+00 1.7900E-04 7.2000E+02 0.0000E+00 1

2 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 0

Location 2:

Low Population Zone 2

1 5

0.0000E+00 2.0000E-05 8.0000E+00 1.3400E-05 2.4000E+01 5.5900E-06 9.6000E+01 1.6000E-06 7.2000E+02 0.0000E+00 1

4 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 0.0000E+00 0

Location 3:

Control Room 3

0 1

2 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 1

4 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 0.0000E+00 Effective Volume Location:

1 6

0.0000E+00 3.5200E-03 2.0000E+00 3.3100E-03

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 139 8.0000E+00 1.4300E-03 2.4000E+01 7.7300E-04 9.6000E+01 6.0700E-04 7.2000E+02 0.0000E+00 Simulation Parameters:

6 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.0000E+00 7.2000E+02 0.0000E+00 Output Filename:

D:\\Staum\\Fitz\\FHA\\24-120\\NF-500_GNF3_24_CREVAS.o0 1

1 1

0 0

End of Scenario File RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:39:18 Plant Description Number of Nuclides = 60 Inventory Power = 1.0000E+00 MWth Plant Power Level = 1.5027E+01 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.0000E+00

)

Name: Reactor Building Compartment volume = 2.6000E+06 (Cubic feet)

Compartment type is Normal Pathways into and out of compartment 1 Exit Pathway Number 1: Reactor Building to Environment Compartment number 2 Name: Environment Compartment type is Environment Pathways into and out of compartment 2 Inlet Pathway Number 1: Reactor Building to Environment Inlet Pathway Number 4: CR Exhaust to Environment Exit Pathway Number 2: CR Air Intake - UnFilter Exit Pathway Number 3: CR Air Intake - Filter Compartment number 3 Name: Control Room Compartment volume = 1.0100E+05 (Cubic feet)

Compartment type is Control Room Pathways into and out of compartment 3 Inlet Pathway Number 2: CR Air Intake - UnFilter Inlet Pathway Number 3: CR Air Intake - Filter Exit Pathway Number 4: CR Exhaust to Environment

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 140 Total number of pathways = 4 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:39:18 Scenario Description Radioactive Decay is enabled Calculation of Daughters is enabled Release Fractions and Timings GAP EARLY IN-VESSEL LATE RELEASE RELEASE MASS 0.003600 hr 0.0000 hrs 0.0000 hrs (gm)

NOBLES 5.0000E-02 0.0000E+00 0.0000E+00 2.243E+00 IODINE 2.5000E-04 0.0000E+00 0.0000E+00 1.371E-03 CESIUM 1.2000E-01 0.0000E+00 0.0000E+00 0.000E+00 TELLURIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 STRONTIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 BARIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 RUTHENIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 CERIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 LANTHANUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 Inventory Power = 15. MWt Nuclide Group Specific half Whole Body Inhaled Inhaled Name Inventory life DCF Thyroid Effective (Ci/MWt) (s) (Sv-m3/Bq-s) (Sv/Bq) (Sv/Bq)

Kr-83m 1 1.580E+01 6.588E+03 1.500E-18 0.000E+00 0.000E+00 Kr-85 1 1.052E+03 3.383E+08 1.190E-16 0.000E+00 0.000E+00 Kr-85m 1 2.140E+02 1.613E+04 7.480E-15 0.000E+00 0.000E+00 Kr-87 1 3.680E-02 4.578E+03 4.120E-14 0.000E+00 0.000E+00 Kr-88 1 6.740E+01 1.022E+04 1.020E-13 0.000E+00 0.000E+00 Br-83 2 4.120E+00 8.604E+03 3.820E-16 3.290E-12 2.330E-11 Br-84 2 1.900E-10 1.908E+03 9.410E-14 3.120E-12 2.610E-11 I-130 2 1.850E+02 4.450E+04 1.040E-13 1.990E-08 7.140E-10 I-131 2 4.048E+04 6.947E+05 1.820E-14 2.920E-07 8.890E-09 I-132 2 3.220E+04 8.280E+03 1.120E-13 1.740E-09 1.030E-10 I-133 2 2.610E+04 7.488E+04 2.940E-14 4.860E-08 1.580E-09 I-134 2 1.560E-03 3.156E+03 1.300E-13 2.880E-10 3.550E-11 I-135 2 4.240E+04 2.380E+04 8.294E-14 8.460E-09 3.320E-10 Xe-131m 1 3.750E+02 1.028E+06 3.890E-16 0.000E+00 0.000E+00 Xe-133 1 5.430E+04 4.532E+05 1.560E-15 0.000E+00 0.000E+00 Xe-133m 1 1.550E+03 1.890E+05 1.370E-15 0.000E+00 0.000E+00 Xe-135 1 1.500E+04 3.272E+04 1.190E-14 0.000E+00 0.000E+00 Xe-135m 1 6.920E+02 9.174E+02 2.040E-14 0.000E+00 0.000E+00 Xe-138 1 8.190E-27 8.502E+02 5.770E-14 0.000E+00 0.000E+00 Nuclide Daughter Fraction Daughter Fraction Daughter Fraction Kr-85m Kr-85 0.21 none 0.00 none 0.00 Kr-87 Rb-87 1.00 none 0.00 none 0.00 Kr-88 Rb-88 1.00 none 0.00 none 0.00 Br-83 Kr-83m 1.00 none 0.00 none 0.00 I-131 Xe-131m 0.01 none 0.00 none 0.00 I-133 Xe-133m 0.03 Xe-133 0.97 none 0.00 I-135 Xe-135m 0.15 Xe-135 0.85 none 0.00 Xe-133m Xe-133 1.00 none 0.00 none 0.00 Xe-135 Cs-135 1.00 none 0.00 none 0.00 Xe-135m Xe-135 1.00 none 0.00 none 0.00 Xe-138 Cs-138 1.00 none 0.00 none 0.00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 141 Iodine fractions Aerosol = 0.0000E+00 Elemental = 5.7000E-01 Organic = 4.3000E-01 COMPARTMENT DATA Compartment number 1: Reactor Building Compartment number 2: Environment Compartment number 3: Control Room PATHWAY DATA Pathway number 1: Reactor Building to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 2.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 2: CR Air Intake - UnFilter Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 4.0000E+02 0.0000E+00 0.0000E+00 0.0000E+00 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 3: CR Air Intake - Filter Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 1.7120E+03 0.0000E+00 0.0000E+00 0.0000E+00 1.3333E-01 9.0000E+02 9.7000E+01 9.7000E+01 9.7000E+01 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 4: CR Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 0.0000E+00 2.1120E+03 1.0000E+02 1.0000E+02 1.0000E+02 1.3333E-01 1.3000E+03 1.0000E+02 1.0000E+02 1.0000E+02 7.2000E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s

  • m^-3) 0.0000E+00 1.7900E-04 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 142 7.2000E+02 0.0000E+00 Location Low Population Zone is in compartment 2 Location X/Q Data Time (hr) X/Q (s

  • m^-3) 0.0000E+00 2.0000E-05 8.0000E+00 1.3400E-05 2.4000E+01 5.5900E-06 9.6000E+01 1.6000E-06 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 8.0000E+00 1.8000E-04 2.4000E+01 2.3000E-04 7.2000E+02 0.0000E+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 0.0000E+00 3.5200E-03 2.0000E+00 3.3100E-03 8.0000E+00 1.4300E-03 2.4000E+01 7.7300E-04 9.6000E+01 6.0700E-04 7.2000E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 0.0000E+00 3.5000E-04 7.2000E+02 0.0000E+00 Location Occupancy Factor Data Time (hr) Occupancy Factor 0.0000E+00 1.0000E+00 2.4000E+01 6.0000E-01 9.6000E+01 4.0000E-01 7.2000E+02 0.0000E+00 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.0000E+00 7.2000E+02 0.0000E+00 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:39:18

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 143 Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 6.8221E-04 4.8626E-02 2.1893E-03 Accumulated dose (rem) 6.8221E-04 4.8626E-02 2.1893E-03 Low Population Zone Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 7.6225E-05 5.4331E-03 2.4462E-04 Accumulated dose (rem) 7.6225E-05 5.4331E-03 2.4462E-04 Control Room Doses:

Time (h) = 0.0036 Whole Body Thyroid TEDE Delta dose (rem) 9.8786E-07 1.6809E-03 5.3084E-05 Accumulated dose (rem) 9.8786E-07 1.6809E-03 5.3084E-05 Control Room Compartment Nuclide Inventory:

Time (h) = 0.0036 Ci kg Atoms Decay Kr-83m 1.7171E-04 8.3225E-15 6.0384E+10 5.8471E+07 Kr-85 1.1448E-02 2.9178E-08 2.0672E+17 3.8963E+09 Kr-85m 2.3274E-03 2.8281E-13 2.0037E+12 7.9231E+08 Kr-87 3.9966E-07 1.4110E-17 9.7667E+07 1.3612E+05 Kr-88 7.3279E-04 5.8440E-14 3.9992E+11 2.4949E+08 Br-83 2.2393E-07 1.4175E-17 1.0285E+08 7.6245E+04 I-130 1.0064E-05 5.1599E-15 2.3903E+10 3.4255E+06 I-131 2.2024E-03 1.7765E-11 8.1668E+13 7.4962E+08 I-132 1.7501E-03 1.6954E-13 7.7350E+11 5.9588E+08 I-133 1.4199E-03 1.2534E-12 5.6755E+12 4.8330E+08 I-134 8.4637E-11 3.1727E-21 1.4258E+04 2.8836E+01 I-135 2.3061E-03 6.5665E-13 2.9292E+12 7.8500E+08 Xe-131m 4.0806E-03 4.8718E-11 2.2396E+14 1.3889E+09 Xe-133 5.9087E-01 3.1567E-09 1.4293E+16 2.0111E+11 Xe-133m 1.6866E-02 3.7588E-11 1.7020E+14 5.7406E+09 Xe-135 1.6320E-01 6.3908E-11 2.8508E+14 5.5553E+10 Xe-135m 7.5835E-03 8.3251E-14 3.7137E+11 2.5885E+09 Control Room Transport Group Inventory:

Time (h) = 0.0036 Atmosphere Sump Noble gases (atoms) 2.2170E+17 0.0000E+00 Elemental I (atoms) 5.1910E+13 0.0000E+00 Organic I (atoms) 3.9160E+13 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 8.7972E-13 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 9.9191E-13 Total I (Ci) 7.6785E-03 CR Air Intake - UnFilter Transport Group Inventory:

Pathway Time (h) = 0.0036 Filtered Transported Noble gases (atoms) 0.0000E+00 4.2052E+16 Elemental I (atoms) 0.0000E+00 9.8465E+12 Organic I (atoms) 0.0000E+00 7.4281E+12 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Air Intake - Filter Transport Group Inventory:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 144 Pathway Time (h) = 0.0036 Filtered Transported Noble gases (atoms) 0.0000E+00 1.7998E+17 Elemental I (atoms) 0.0000E+00 4.2143E+13 Organic I (atoms) 0.0000E+00 3.1792E+13 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 0.0036 Filtered Transported Noble gases (atoms) 3.3406E+14 0.0000E+00 Elemental I (atoms) 7.8221E+10 0.0000E+00 Organic I (atoms) 5.9009E+10 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 0.1333 Whole Body Thyroid TEDE Delta dose (rem) 4.2279E-02 3.0246E+00 1.3602E-01 Accumulated dose (rem) 4.2961E-02 3.0732E+00 1.3821E-01 Low Population Zone Doses:

Time (h) = 0.1333 Whole Body Thyroid TEDE Delta dose (rem) 4.7239E-03 3.3794E-01 1.5197E-02 Accumulated dose (rem) 4.8002E-03 3.4338E-01 1.5442E-02 Control Room Doses:

Time (h) = 0.1333 Whole Body Thyroid TEDE Delta dose (rem) 2.7977E-03 4.7923E+00 1.5132E-01 Accumulated dose (rem) 2.7987E-03 4.7940E+00 1.5137E-01 Control Room Compartment Nuclide Inventory:

Time (h) = 0.1333 Ci kg Atoms Decay Kr-83m 9.5021E-03 4.6055E-13 3.3416E+12 1.4216E+11 Kr-85 6.6534E-01 1.6959E-06 1.2015E+19 9.7234E+12 Kr-85m 1.3258E-01 1.6111E-11 1.1414E+14 1.9562E+12 Kr-87 2.1643E-05 7.6408E-16 5.2889E+09 3.2721E+08 Kr-88 4.1263E-02 3.2907E-12 2.2519E+13 6.1221E+11 Br-83 1.2534E-05 7.9343E-16 5.7568E+09 1.8651E+08 I-130 5.8066E-04 2.9772E-13 1.3792E+12 8.5154E+09 I-131 1.2795E-01 1.0320E-09 4.7444E+15 1.8703E+12 I-132 9.7815E-02 9.4762E-12 4.3233E+13 1.4565E+12 I-133 8.2170E-02 7.2536E-11 3.2844E+14 1.2033E+12 I-134 4.4396E-09 1.6642E-19 7.4792E+05 6.8163E+04 I-135 1.3222E-01 3.7649E-11 1.6795E+14 1.9448E+12 Xe-131m 2.3710E-01 2.8306E-09 1.3012E+16 3.4654E+12 Xe-133 3.4318E+01 1.8334E-07 8.3015E+17 5.0169E+14 Xe-133m 9.7859E-01 2.1809E-09 9.8751E+15 1.4313E+13 Xe-135 9.3973E+00 3.6798E-09 1.6415E+16 1.3793E+14 Xe-135m 3.1773E-01 3.4880E-12 1.5559E+13 5.4313E+12 Control Room Transport Group Inventory:

Time (h) = 0.1333 Atmosphere Sump Noble gases (atoms) 1.2885E+19 0.0000E+00 Elemental I (atoms) 3.0127E+15 0.0000E+00 Organic I (atoms) 2.2727E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 5.1062E-11 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 5.7494E-11 Total I (Ci) 4.4015E-01

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 145 CR Air Intake - UnFilter Transport Group Inventory:

Pathway Time (h) = 0.1333 Filtered Transported Noble gases (atoms) 0.0000E+00 2.6583E+18 Elemental I (atoms) 0.0000E+00 6.2229E+14 Organic I (atoms) 0.0000E+00 4.6945E+14 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Air Intake - Filter Transport Group Inventory:

Pathway Time (h) = 0.1333 Filtered Transported Noble gases (atoms) 0.0000E+00 1.1378E+19 Elemental I (atoms) 0.0000E+00 2.6634E+15 Organic I (atoms) 0.0000E+00 2.0092E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 0.1333 Filtered Transported Noble gases (atoms) 1.1524E+18 0.0000E+00 Elemental I (atoms) 2.6972E+14 0.0000E+00 Organic I (atoms) 2.0347E+14 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.1320E-01 8.5277E+00 3.7727E-01 Accumulated dose (rem) 1.5616E-01 1.1601E+01 5.1547E-01 Low Population Zone Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 1.2648E-02 9.5282E-01 4.2153E-02 Accumulated dose (rem) 1.7449E-02 1.2962E+00 5.7595E-02 Control Room Doses:

Time (h) = 2.0000 Whole Body Thyroid TEDE Delta dose (rem) 9.0760E-02 1.0439E+02 3.3211E+00 Accumulated dose (rem) 9.3558E-02 1.0918E+02 3.4725E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 2.0000 Ci kg Atoms Decay Kr-83m 4.0898E-03 1.9822E-13 1.4382E+12 2.5484E+12 Kr-85 5.8036E-01 1.4792E-06 1.0480E+19 2.3774E+14 Kr-85m 8.6639E-02 1.0528E-11 7.4588E+13 4.1932E+13 Kr-87 6.8249E-06 2.4094E-16 1.6678E+09 5.1777E+09 Kr-88 2.2822E-02 1.8201E-12 1.2455E+13 1.2199E+13 Br-83 3.2487E-06 2.0564E-16 1.4921E+09 2.1781E+09 I-130 2.3290E-04 1.1942E-13 5.5319E+11 1.1837E+11 I-131 5.6603E-02 4.5657E-10 2.0989E+15 2.7093E+13 I-132 2.4820E-02 2.4046E-12 1.0970E+13 1.6872E+13 I-133 3.4388E-02 3.0357E-11 1.3745E+14 1.7028E+13 I-134 4.5194E-10 1.6941E-20 7.6137E+04 5.7574E+05 I-135 4.8417E-02 1.3787E-11 6.1501E+13 2.6038E+13 Xe-131m 2.0588E-01 2.4580E-09 1.1299E+16 8.4555E+13 Xe-133 2.9638E+01 1.5834E-07 7.1694E+17 1.2210E+16 Xe-133m 8.3287E-01 1.8562E-09 8.4045E+15 3.4597E+14 Xe-135 7.1252E+00 2.7901E-09 1.2446E+16 3.1630E+15 Xe-135m 1.0771E-02 1.1825E-13 5.2747E+11 3.1904E+13

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 146 Control Room Transport Group Inventory:

Time (h) = 2.0000 Atmosphere Sump Noble gases (atoms) 1.1229E+19 0.0000E+00 Elemental I (atoms) 1.3163E+15 0.0000E+00 Organic I (atoms) 9.9302E+14 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 2.2335E-11 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 2.4726E-11 Total I (Ci) 1.6423E-01 CR Air Intake - UnFilter Transport Group Inventory:

Pathway Time (h) = 2.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0068E+19 Elemental I (atoms) 0.0000E+00 2.3484E+15 Organic I (atoms) 0.0000E+00 1.7716E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Air Intake - Filter Transport Group Inventory:

Pathway Time (h) = 2.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 2.8050E+19 Elemental I (atoms) 3.7673E+15 2.7799E+15 Organic I (atoms) 2.8420E+15 2.0971E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 2.0000 Filtered Transported Noble gases (atoms) 2.6876E+19 0.0000E+00 Elemental I (atoms) 3.7629E+15 0.0000E+00 Organic I (atoms) 2.8386E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.5616E-01 1.1601E+01 5.1547E-01 Low Population Zone Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.7449E-02 1.2962E+00 5.7595E-02 Control Room Doses:

Time (h) = 8.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.3831E-02 3.8617E+01 1.2251E+00 Accumulated dose (rem) 1.2739E-01 1.4780E+02 4.6976E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 8.0000 Ci kg Atoms Decay Kr-83m 4.1058E-06 1.9900E-16 1.4439E+09 3.0032E+12 Kr-85 5.6403E-03 1.4376E-08 1.0185E+17 3.3309E+14 Kr-85m 3.3279E-04 4.0439E-14 2.8650E+11 5.3860E+13 Kr-87 2.5200E-09 8.8964E-20 6.1581E+05 5.8410E+09 Kr-88 5.1286E-05 4.0901E-15 2.7990E+10 1.5069E+13 Br-83 5.5413E-09 3.5077E-19 2.5450E+06 2.5692E+09

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 147 I-130 1.6169E-06 8.2902E-16 3.8403E+09 1.5415E+11 I-131 5.3840E-04 4.3428E-12 1.9964E+13 3.6351E+13 I-132 3.9549E-05 3.8315E-15 1.7480E+10 1.9829E+13 I-133 2.7365E-04 2.4157E-13 1.0938E+12 2.2453E+13 I-135 2.5083E-04 7.1423E-14 3.1861E+11 3.3073E+13 Xe-131m 1.9722E-03 2.3545E-11 1.0824E+14 1.1828E+14 Xe-133 2.7896E-01 1.4903E-09 6.7479E+15 1.7047E+16 Xe-133m 7.4790E-03 1.6668E-11 7.5471E+13 4.8060E+14 Xe-135 4.3952E-02 1.7211E-11 7.6775E+13 4.2328E+15 Xe-135m 4.4706E-05 4.9078E-16 2.1893E+09 3.3086E+13 Control Room Transport Group Inventory:

Time (h) = 8.0000 Atmosphere Sump Noble gases (atoms) 1.0886E+17 0.0000E+00 Elemental I (atoms) 1.2197E+13 0.0000E+00 Organic I (atoms) 9.2010E+12 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 2.0680E-13 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 2.2162E-13 Total I (Ci) 1.1024E-03 CR Air Intake - UnFilter Transport Group Inventory:

Pathway Time (h) = 8.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0068E+19 Elemental I (atoms) 0.0000E+00 2.3484E+15 Organic I (atoms) 0.0000E+00 1.7716E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Air Intake - Filter Transport Group Inventory:

Pathway Time (h) = 8.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 2.8050E+19 Elemental I (atoms) 3.7673E+15 2.7799E+15 Organic I (atoms) 2.8420E+15 2.0971E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 8.0000 Filtered Transported Noble gases (atoms) 3.7991E+19 0.0000E+00 Elemental I (atoms) 5.0529E+15 0.0000E+00 Organic I (atoms) 3.8118E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.5616E-01 1.1601E+01 5.1547E-01 Low Population Zone Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.7449E-02 1.2962E+00 5.7595E-02 Control Room Doses:

Time (h) = 24.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.4499E-04 3.6202E-01 1.1361E-02 Accumulated dose (rem) 1.2763E-01 1.4816E+02 4.7090E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 148 Control Room Compartment Nuclide Inventory:

Time (h) = 24.0000 Ci kg Atoms Decay Kr-85 2.4262E-08 6.1839E-14 4.3812E+11 3.3402E+14 Kr-85m 1.2043E-10 1.4634E-20 1.0368E+05 5.3905E+13 I-131 2.1868E-09 1.7639E-17 8.1088E+07 3.6440E+13 I-133 6.9073E-10 6.0975E-19 2.7609E+06 2.2496E+13 I-135 2.0155E-10 5.7391E-20 2.5601E+05 3.3110E+13 Xe-131m 8.1620E-09 9.7443E-17 4.4795E+08 1.1860E+14 Xe-133 1.1014E-06 5.8840E-15 2.6642E+10 1.7093E+16 Xe-133m 2.6054E-08 5.8065E-17 2.6291E+08 4.8182E+14 Xe-135 5.6141E-08 2.1984E-17 9.8067E+07 4.2394E+15 Control Room Transport Group Inventory:

Time (h) = 24.0000 Atmosphere Sump Noble gases (atoms) 4.6557E+11 0.0000E+00 Elemental I (atoms) 4.7944E+07 0.0000E+00 Organic I (atoms) 3.6168E+07 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 8.0686E-19 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 8.3505E-19 Total I (Ci) 3.0805E-09 CR Air Intake - UnFilter Transport Group Inventory:

Pathway Time (h) = 24.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0068E+19 Elemental I (atoms) 0.0000E+00 2.3484E+15 Organic I (atoms) 0.0000E+00 1.7716E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Air Intake - Filter Transport Group Inventory:

Pathway Time (h) = 24.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 2.8050E+19 Elemental I (atoms) 3.7673E+15 2.7799E+15 Organic I (atoms) 2.8420E+15 2.0971E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 24.0000 Filtered Transported Noble gases (atoms) 3.8099E+19 0.0000E+00 Elemental I (atoms) 5.0650E+15 0.0000E+00 Organic I (atoms) 3.8209E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.5616E-01 1.1601E+01 5.1547E-01 Low Population Zone Doses:

Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.7449E-02 1.2962E+00 5.7595E-02 Control Room Doses:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 149 Time (h) = 96.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.9100E-10 8.9142E-07 2.7639E-08 Accumulated dose (rem) 1.2763E-01 1.4816E+02 4.7090E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 96.0000 Ci kg Atoms Decay Control Room Transport Group Inventory:

Time (h) = 96.0000 Atmosphere Sump Noble gases (atoms) 3.2424E-13 0.0000E+00 Elemental I (atoms) 2.5454E-17 0.0000E+00 Organic I (atoms) 1.9202E-17 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 4.2199E-43 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 4.2356E-43 Total I (Ci) 1.2441E-33 CR Air Intake - UnFilter Transport Group Inventory:

Pathway Time (h) = 96.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0068E+19 Elemental I (atoms) 0.0000E+00 2.3484E+15 Organic I (atoms) 0.0000E+00 1.7716E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Air Intake - Filter Transport Group Inventory:

Pathway Time (h) = 96.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 2.8050E+19 Elemental I (atoms) 3.7673E+15 2.7799E+15 Organic I (atoms) 2.8420E+15 2.0971E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 96.0000 Filtered Transported Noble gases (atoms) 3.8099E+19 0.0000E+00 Elemental I (atoms) 5.0650E+15 0.0000E+00 Organic I (atoms) 3.8209E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.5616E-01 1.1601E+01 5.1547E-01 Low Population Zone Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 1.7449E-02 1.2962E+00 5.7595E-02 Control Room Doses:

Time (h) = 720.0000 Whole Body Thyroid TEDE Delta dose (rem) 9.1378E-35 3.1118E-31 9.5691E-33 Accumulated dose (rem) 1.2763E-01 1.4816E+02 4.7090E+00 Control Room Compartment Nuclide Inventory:

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 150 Time (h) = 720.0000 Ci kg Atoms Decay Control Room Transport Group Inventory:

Time (h) = 720.0000 Atmosphere Sump Noble gases (atoms) 1.6017-222 0.0000E+00 Elemental I (atoms) 1.3918-227 0.0000E+00 Organic I (atoms) 1.0500-227 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 2.3025-253 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 2.3025-253 Total I (Ci) 6.5851-244 CR Air Intake - UnFilter Transport Group Inventory:

Pathway Time (h) = 720.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 1.0068E+19 Elemental I (atoms) 0.0000E+00 2.3484E+15 Organic I (atoms) 0.0000E+00 1.7716E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Air Intake - Filter Transport Group Inventory:

Pathway Time (h) = 720.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 2.8050E+19 Elemental I (atoms) 3.7673E+15 2.7799E+15 Organic I (atoms) 2.8420E+15 2.0971E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 720.0000 Filtered Transported Noble gases (atoms) 3.8099E+19 0.0000E+00 Elemental I (atoms) 5.0650E+15 0.0000E+00 Organic I (atoms) 3.8209E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 839 I-131 Summary Reactor Building Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 0.000 2.3453E+01 1.5007E-02 5.2641E-05 0.004 1.5144E+02 6.2868E-01 2.2024E-03 0.133 1.1228E+02 3.9728E+01 1.2795E-01 0.500 4.8191E+01 1.0370E+02 1.3499E-01 0.800 2.4123E+01 1.2773E+02 1.2197E-01 1.100 1.2075E+01 1.3976E+02 1.0415E-01 1.400 6.0447E+00 1.4578E+02 8.6283E-02 1.700 3.0258E+00 1.4879E+02 7.0248E-02 2.000 1.5146E+00 1.5030E+02 5.6603E-02 2.300 1.5130E+00 1.5030E+02 4.4849E-02 2.600 1.5114E+00 1.5030E+02 3.5536E-02 2.900 1.5097E+00 1.5030E+02 2.8156E-02 3.200 1.5081E+00 1.5030E+02 2.2310E-02 3.500 1.5065E+00 1.5030E+02 1.7677E-02 3.800 1.5049E+00 1.5030E+02 1.4006E-02 4.100 1.5032E+00 1.5030E+02 1.1098E-02 4.400 1.5016E+00 1.5030E+02 8.7931E-03 4.700 1.5000E+00 1.5030E+02 6.9672E-03

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 151 5.000 1.4984E+00 1.5030E+02 5.5204E-03 5.300 1.4968E+00 1.5030E+02 4.3740E-03 5.600 1.4952E+00 1.5030E+02 3.4657E-03 5.900 1.4936E+00 1.5030E+02 2.7461E-03 6.200 1.4920E+00 1.5030E+02 2.1758E-03 6.500 1.4903E+00 1.5030E+02 1.7240E-03 6.800 1.4887E+00 1.5030E+02 1.3660E-03 7.100 1.4871E+00 1.5030E+02 1.0823E-03 7.400 1.4855E+00 1.5030E+02 8.5758E-04 7.700 1.4839E+00 1.5030E+02 6.7950E-04 8.000 1.4823E+00 1.5030E+02 5.3840E-04 8.300 1.4807E+00 1.5030E+02 4.2659E-04 8.600 1.4791E+00 1.5030E+02 3.3801E-04 8.900 1.4776E+00 1.5030E+02 2.6782E-04 9.200 1.4760E+00 1.5030E+02 2.1220E-04 9.500 1.4744E+00 1.5030E+02 1.6814E-04 9.800 1.4728E+00 1.5030E+02 1.3322E-04 10.100 1.4712E+00 1.5030E+02 1.0556E-04 10.400 1.4696E+00 1.5030E+02 8.3639E-05 24.000 1.3995E+00 1.5030E+02 2.1868E-09 96.000 1.0806E+00 1.5030E+02 1.1995E-33 720.000 1.1486E-01 1.5030E+02 6.5851-244 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone Control Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 0.000 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.004 4.8626E-02 2.1893E-03 5.4331E-03 2.4462E-04 1.6809E-03 5.3084E-05 0.133 3.0732E+00 1.3821E-01 3.4338E-01 1.5442E-02 4.7940E+00 1.5137E-01 0.500 8.0149E+00 3.5831E-01 8.9552E-01 4.0035E-02 3.1588E+01 1.0012E+00 0.800 9.8669E+00 4.3993E-01 1.1024E+00 4.9154E-02 5.2578E+01 1.6694E+00 1.100 1.0792E+01 4.8041E-01 1.2058E+00 5.3677E-02 7.0943E+01 2.2545E+00 1.400 1.1254E+01 5.0052E-01 1.2575E+00 5.5924E-02 8.6351E+01 2.7454E+00 1.700 1.1485E+01 5.1051E-01 1.2833E+00 5.7040E-02 9.8977E+01 3.1476E+00 2.000 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.0918E+02 3.4725E+00 2.300 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.1733E+02 3.7315E+00 2.600 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.2377E+02 3.9361E+00 2.900 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.2886E+02 4.0979E+00 3.200 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.3289E+02 4.2258E+00 3.500 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.3608E+02 4.3269E+00 3.800 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.3860E+02 4.4068E+00 4.100 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4060E+02 4.4700E+00 4.400 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4218E+02 4.5200E+00 4.700 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4342E+02 4.5595E+00 5.000 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4441E+02 4.5908E+00 5.300 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4520E+02 4.6155E+00 5.600 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4581E+02 4.6350E+00 5.900 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4630E+02 4.6505E+00 6.200 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4669E+02 4.6627E+00 6.500 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4700E+02 4.6724E+00 6.800 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4724E+02 4.6800E+00 7.100 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4743E+02 4.6861E+00 7.400 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4759E+02 4.6909E+00 7.700 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4771E+02 4.6946E+00 8.000 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4780E+02 4.6976E+00 8.300 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4788E+02 4.7000E+00 8.600 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4794E+02 4.7019E+00 8.900 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4798E+02 4.7034E+00 9.200 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4802E+02 4.7045E+00 9.500 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4805E+02 4.7055E+00 9.800 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4807E+02 4.7062E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 152 10.100 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4809E+02 4.7068E+00 10.400 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4811E+02 4.7072E+00 24.000 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4816E+02 4.7090E+00 96.000 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4816E+02 4.7090E+00 720.000 1.1601E+01 5.1547E-01 1.2962E+00 5.7595E-02 1.4816E+02 4.7090E+00 Worst Two-Hour Doses Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 0.0 1.5616E-01 1.1601E+01 5.1547E-01

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 153 NF-500_GNF2_104.o0 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:36:35 File information Plant file = D:\\Staum\\Fitz\\FHA\\104 hr\\NF-500_GNF2_104.psf Inventory file = d:\\staum\\fitz\\fha\\jfha_source_96.nif Release file = d:\\staum\\fitz\\fha\\jafha_rft_with_df.rft Dose Conversion file = d:\\staum\\fitz\\fha\\jafha_fg11&12.inp Radtrad 3.03 4/15/2001 JAF FHA Occurring In Reactor Bldg With RB Vent Release, Pool DF = 200, Peaking Factor =

1.82, Decay Time = 96 Hrs, CR Normal Flow Rate =2,112 cfm, No SGTS Filtration, and Plant Vent Release @ 99,800 cfm Nuclide Inventory File:

d:\\staum\\fitz\\fha\\jfha_source_96.nif Plant Power Level:

1.5780E+01 Compartments:

3 Compartment 1:

Reactor Building 3

2.6000E+06 0

0 0

0 0

Compartment 2:

Environment 2

0.0000E+00 0

0 0

0 0

Compartment 3:

Control Room 1

1.0100E+05 0

0 0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 154 0

0 Pathways:

3 Pathway 1:

Reactor Building to Environment 1

2 2

Pathway 2:

CR Air Intake 2

3 2

Pathway 3:

CR Exhaust to Environment 3

2 2

End of Plant Model File Scenario Description Name:

Plant Model Filename:

Source Term:

1 1 1.0000E+00 d:\\staum\\fitz\\fha\\jafha_fg11&12.inp d:\\staum\\fitz\\fha\\jafha_rft_with_df.rft 8.0000E+00 1

0.0000E+00 5.7000E-01 4.3000E-01 1.0000E+00 Overlying Pool:

0 0.0000E+00 0

0 0

0 Compartments:

3 Compartment 1:

0 1

0 0

0 0

0 0

0 Compartment 2:

0 1

0 0

0 0

0 0

0 Compartment 3:

1 1

0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 155 0

0 0

0 0

0 Pathways:

3 Pathway 1:

0 0

0 0

0 1

3 8.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 1.0000E+01 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2800E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 2:

0 0

0 0

0 1

2 8.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2800E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 3:

0 0

0 0

0 1

2 8.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2800E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Dose Locations:

3 Location 1:

Exclusion Area Boundary 2

1 2

8.0000E+00 1.7900E-04

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 156 7.2800E+02 0.0000E+00 1

2 8.0000E+00 3.5000E-04 7.2800E+02 0.0000E+00 0

Location 2:

Low Population Zone 2

1 5

8.0000E+00 2.0000E-05 1.6000E+01 1.3400E-05 3.2000E+01 5.5900E-06 1.0400E+02 1.6000E-06 7.2800E+02 0.0000E+00 1

4 8.0000E+00 3.5000E-04 1.6000E+01 1.8000E-04 3.2000E+01 2.3000E-04 7.2800E+02 0.0000E+00 0

Location 3:

Control Room 3

0 1

2 8.0000E+00 3.5000E-04 7.2800E+02 0.0000E+00 1

4 8.0000E+00 1.0000E+00 3.2000E+01 6.0000E-01 1.0400E+02 4.0000E-01 7.2800E+02 0.0000E+00 Effective Volume Location:

1 6

8.0000E+00 3.5200E-03 1.0000E+01 3.3100E-03 1.6000E+01 1.4300E-03 3.2000E+01 7.7300E-04 1.0400E+02 6.0700E-04 7.2800E+02 0.0000E+00 Simulation Parameters:

6 8.0000E+00 1.0000E-01 1.0000E+01 5.0000E-01 1.6000E+01 1.0000E+00 3.2000E+01 2.0000E+00 1.0400E+02 4.0000E+00 7.2800E+02 0.0000E+00 Output Filename:

D:\\Staum\\Fitz\\FHA\\104 hr\\NF-500_GNF2_104.o0 1

1 1

0 0

End of Scenario File

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 157 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:36:35 Plant Description Number of Nuclides = 60 Inventory Power = 1.0000E+00 MWth Plant Power Level = 1.5780E+01 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.0000E+00

)

Name: Reactor Building Compartment volume = 2.6000E+06 (Cubic feet)

Compartment type is Normal Pathways into and out of compartment 1 Exit Pathway Number 1: Reactor Building to Environment Compartment number 2 Name: Environment Compartment type is Environment Pathways into and out of compartment 2 Inlet Pathway Number 1: Reactor Building to Environment Inlet Pathway Number 3: CR Exhaust to Environment Exit Pathway Number 2: CR Air Intake Compartment number 3 Name: Control Room Compartment volume = 1.0100E+05 (Cubic feet)

Compartment type is Control Room Pathways into and out of compartment 3 Inlet Pathway Number 2: CR Air Intake Exit Pathway Number 3: CR Exhaust to Environment Total number of pathways = 3 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:36:35 Scenario Description Time between shutdown and first release = 8.0000E+00 (Hours)

Radioactive Decay is enabled Calculation of Daughters is enabled Release Fractions and Timings GAP EARLY IN-VESSEL LATE RELEASE RELEASE MASS 0.003600 hr 0.0000 hrs 0.0000 hrs (gm)

NOBLES 5.0000E-02 0.0000E+00 0.0000E+00 2.288E+00 IODINE 2.5000E-04 0.0000E+00 0.0000E+00 1.028E-03 CESIUM 1.2000E-01 0.0000E+00 0.0000E+00 0.000E+00 TELLURIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 STRONTIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 158 BARIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 RUTHENIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 CERIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 LANTHANUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 Inventory Power = 16. MWt Nuclide Group Specific half Whole Body Inhaled Inhaled Name Inventory life DCF Thyroid Effective (Ci/MWt) (s) (Sv-m3/Bq-s) (Sv/Bq) (Sv/Bq)

Kr-83m 1 1.800E-08 6.588E+03 1.500E-18 0.000E+00 0.000E+00 Kr-85 1 1.052E+03 3.383E+08 1.190E-16 0.000E+00 0.000E+00 Kr-85m 1 3.110E-03 1.613E+04 7.480E-15 0.000E+00 0.000E+00 Kr-87 1 3.360E-19 4.578E+03 4.120E-14 0.000E+00 0.000E+00 Kr-88 1 1.570E-06 1.022E+04 1.020E-13 0.000E+00 0.000E+00 Br-83 2 3.840E-09 8.604E+03 3.820E-16 3.290E-12 2.330E-11 I-130 2 3.270E+00 4.450E+04 1.040E-13 1.990E-08 7.140E-10 I-131 2 3.184E+04 6.947E+05 1.820E-14 2.920E-07 8.890E-09 I-132 2 1.700E+04 8.280E+03 1.120E-13 1.740E-09 1.030E-10 I-133 2 2.370E+03 7.488E+04 2.940E-14 4.860E-08 1.580E-09 I-134 2 2.970E-28 3.156E+03 1.300E-13 2.880E-10 3.550E-11 I-135 2 2.130E+00 2.380E+04 8.294E-14 8.460E-09 3.320E-10 Xe-131m 1 3.540E+02 1.028E+06 3.890E-16 0.000E+00 0.000E+00 Xe-133 1 3.980E+04 4.532E+05 1.560E-15 0.000E+00 0.000E+00 Xe-133m 1 7.450E+02 1.890E+05 1.370E-15 0.000E+00 0.000E+00 Xe-135 1 1.050E+02 3.272E+04 1.190E-14 0.000E+00 0.000E+00 Xe-135m 1 3.480E-01 9.174E+02 2.040E-14 0.000E+00 0.000E+00 Nuclide Daughter Fraction Daughter Fraction Daughter Fraction Kr-85m Kr-85 0.21 none 0.00 none 0.00 Kr-87 Rb-87 1.00 none 0.00 none 0.00 Kr-88 Rb-88 1.00 none 0.00 none 0.00 Br-83 Kr-83m 1.00 none 0.00 none 0.00 I-131 Xe-131m 0.01 none 0.00 none 0.00 I-133 Xe-133m 0.03 Xe-133 0.97 none 0.00 I-135 Xe-135m 0.15 Xe-135 0.85 none 0.00 Xe-133m Xe-133 1.00 none 0.00 none 0.00 Xe-135 Cs-135 1.00 none 0.00 none 0.00 Xe-135m Xe-135 1.00 none 0.00 none 0.00 Iodine fractions Aerosol = 0.0000E+00 Elemental = 5.7000E-01 Organic = 4.3000E-01 COMPARTMENT DATA Compartment number 1: Reactor Building Compartment number 2: Environment Compartment number 3: Control Room PATHWAY DATA Pathway number 1: Reactor Building to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 8.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 1.0000E+01 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2800E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 159 Pathway number 2: CR Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 8.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2800E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 3: CR Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 8.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2800E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s

  • m^-3) 8.0000E+00 1.7900E-04 7.2800E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 8.0000E+00 3.5000E-04 7.2800E+02 0.0000E+00 Location Low Population Zone is in compartment 2 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 8.0000E+00 2.0000E-05 1.6000E+01 1.3400E-05 3.2000E+01 5.5900E-06 1.0400E+02 1.6000E-06 7.2800E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 8.0000E+00 3.5000E-04 1.6000E+01 1.8000E-04 3.2000E+01 2.3000E-04 7.2800E+02 0.0000E+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 8.0000E+00 3.5200E-03 1.0000E+01 3.3100E-03 1.6000E+01 1.4300E-03 3.2000E+01 7.7300E-04 1.0400E+02 6.0700E-04 7.2800E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 8.0000E+00 3.5000E-04 7.2800E+02 0.0000E+00 Location Occupancy Factor Data Time (hr) Occupancy Factor 8.0000E+00 1.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 160 3.2000E+01 6.0000E-01 1.0400E+02 4.0000E-01 7.2800E+02 0.0000E+00 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.0000E+00 7.2000E+02 0.0000E+00 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:36:35 Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:

Time (h) = 8.0036 Whole Body Thyroid TEDE Delta dose (rem) 1.4131E-04 3.4496E-02 1.1925E-03 Accumulated dose (rem) 1.4131E-04 3.4496E-02 1.1925E-03 Low Population Zone Doses:

Time (h) = 8.0036 Whole Body Thyroid TEDE Delta dose (rem) 1.5789E-05 3.8544E-03 1.3324E-04 Accumulated dose (rem) 1.5789E-05 3.8544E-03 1.3324E-04 Control Room Doses:

Time (h) = 8.0036 Whole Body Thyroid TEDE Delta dose (rem) 2.0464E-07 1.1925E-03 3.6543E-05 Accumulated dose (rem) 2.0464E-07 1.1925E-03 3.6543E-05 Control Room Compartment Nuclide Inventory:

Time (h) = 8.0036 Ci kg Atoms Decay Kr-85 1.2021E-02 3.0639E-08 2.1707E+17 4.0913E+09 Kr-85m 1.0301E-08 1.2518E-18 8.8686E+06 3.5069E+03 I-130 1.1927E-07 6.1152E-17 2.8328E+08 4.0597E+04 I-131 1.7676E-03 1.4258E-11 6.5545E+13 6.0163E+08 I-132 8.7061E-05 8.4343E-15 3.8479E+10 2.9643E+07 I-133 1.0371E-04 9.1551E-14 4.1454E+11 3.5300E+07 I-135 5.2576E-08 1.4971E-17 6.6783E+07 1.7897E+04 Xe-131m 4.0432E-03 4.8271E-11 2.2190E+14 1.3762E+09 Xe-133 4.3653E-01 2.3321E-09 1.0560E+16 1.4858E+11 Xe-133m 7.7286E-03 1.7224E-11 7.7990E+13 2.6306E+09

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 161 Xe-135 6.5901E-04 2.5806E-13 1.1512E+12 2.2432E+08 Xe-135m 1.8195E-06 1.9974E-17 8.9101E+07 6.2141E+05 Control Room Transport Group Inventory:

Time (h) = 8.0036 Atmosphere Sump Noble gases (atoms) 2.2793E+17 0.0000E+00 Elemental I (atoms) 3.7619E+13 0.0000E+00 Organic I (atoms) 2.8379E+13 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 6.2427E-13 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 6.2884E-13 Total I (Ci) 1.9585E-03 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 8.0036 Filtered Transported Noble gases (atoms) 0.0000E+00 2.2827E+17 Elemental I (atoms) 0.0000E+00 3.7676E+13 Organic I (atoms) 0.0000E+00 2.8422E+13 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 8.0036 Filtered Transported Noble gases (atoms) 3.4345E+14 0.0000E+00 Elemental I (atoms) 5.6686E+10 0.0000E+00 Organic I (atoms) 4.2763E+10 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 10.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.3576E-02 8.2142E+00 2.8388E-01 Accumulated dose (rem) 3.3717E-02 8.2487E+00 2.8508E-01 Low Population Zone Doses:

Time (h) = 10.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.7515E-03 9.1779E-01 3.1719E-02 Accumulated dose (rem) 3.7673E-03 9.2164E-01 3.1852E-02 Control Room Doses:

Time (h) = 10.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.3191E-02 1.3580E+02 4.1612E+00 Accumulated dose (rem) 2.3192E-02 1.3580E+02 4.1612E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 10.0000 Ci kg Atoms Decay Kr-85 4.5722E-01 1.1654E-06 8.2566E+18 2.5957E+14 Kr-85m 2.8772E-07 3.4961E-17 2.4770E+08 1.9484E+08 Kr-88 5.9440E-11 4.7403E-21 3.2440E+04 4.4689E+04 I-130 4.0561E-06 2.0797E-15 9.6340E+09 2.4529E+09 I-131 6.6755E-02 5.3846E-10 2.4753E+15 3.8050E+13 I-132 1.8144E-03 1.7578E-13 8.0194E+11 1.4603E+12 I-133 3.6909E-03 3.2582E-12 1.4753E+13 2.1754E+12 I-135 1.6221E-06 4.6189E-16 2.0604E+09 1.0371E+09 Xe-131m 1.5305E-01 1.8273E-09 8.4000E+15 8.7125E+13 Xe-133 1.6426E+01 8.7755E-08 3.9735E+17 9.3819E+15 Xe-133m 2.8633E-01 6.3813E-10 2.8894E+15 1.6498E+14 Xe-135 2.1529E-02 8.4305E-12 3.7607E+13 1.3322E+13 Xe-135m 5.9097E-07 6.4876E-18 2.8940E+07 7.7815E+09

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 162 Control Room Transport Group Inventory:

Time (h) = 10.0000 Atmosphere Sump Noble gases (atoms) 8.6653E+18 0.0000E+00 Elemental I (atoms) 1.4198E+15 0.0000E+00 Organic I (atoms) 1.0711E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 2.3560E-11 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 2.3709E-11 Total I (Ci) 7.2262E-02 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 10.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 5.4658E+19 Elemental I (atoms) 0.0000E+00 9.0090E+15 Organic I (atoms) 0.0000E+00 6.7963E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 10.0000 Filtered Transported Noble gases (atoms) 4.5991E+19 0.0000E+00 Elemental I (atoms) 7.5668E+15 0.0000E+00 Organic I (atoms) 5.7083E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 16.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.3717E-02 8.2487E+00 2.8508E-01 Low Population Zone Doses:

Time (h) = 16.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.7673E-03 9.2164E-01 3.1852E-02 Control Room Doses:

Time (h) = 16.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.3189E-03 2.5508E+01 7.8149E-01 Accumulated dose (rem) 2.7511E-02 1.6131E+02 4.9427E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 16.0000 Ci kg Atoms Decay Kr-85 2.4591E-04 6.2678E-10 4.4407E+15 3.0510E+14 Kr-85m 6.1159E-11 7.4317E-21 5.2653E+04 2.2035E+08 I-130 1.5583E-09 7.9898E-19 3.7012E+06 2.8396E+09 I-131 3.5139E-05 2.8344E-13 1.3030E+12 4.4680E+13 I-132 1.6000E-07 1.5500E-17 7.0715E+07 1.6060E+12 I-133 1.6254E-06 1.4349E-15 6.4969E+09 2.5334E+12 I-135 4.6504E-10 1.3242E-19 5.9071E+05 1.1862E+09 Xe-131m 8.1136E-05 9.6867E-13 4.4530E+12 1.0234E+14 Xe-133 8.5526E-03 4.5692E-11 2.0689E+14 1.1011E+16 Xe-133m 1.4228E-04 3.1710E-13 1.4358E+12 1.9320E+14 Xe-135 7.3284E-06 2.8697E-15 1.2801E+10 1.5343E+13 Control Room Transport Group Inventory:

Time (h) = 16.0000 Atmosphere Sump Noble gases (atoms) 4.6535E+15 0.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 163 Elemental I (atoms) 7.4644E+11 0.0000E+00 Organic I (atoms) 5.6311E+11 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 1.2381E-14 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 1.2440E-14 Total I (Ci) 3.6925E-05 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 16.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 5.4658E+19 Elemental I (atoms) 0.0000E+00 9.0090E+15 Organic I (atoms) 0.0000E+00 6.7963E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 16.0000 Filtered Transported Noble gases (atoms) 5.4650E+19 0.0000E+00 Elemental I (atoms) 8.9817E+15 0.0000E+00 Organic I (atoms) 6.7757E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 32.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.3717E-02 8.2487E+00 2.8508E-01 Low Population Zone Doses:

Time (h) = 32.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.7673E-03 9.2164E-01 3.1852E-02 Control Room Doses:

Time (h) = 32.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.2310E-06 1.3417E-02 4.1092E-04 Accumulated dose (rem) 2.7513E-02 1.6132E+02 4.9431E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 32.0000 Ci kg Atoms Decay Kr-85 4.7042E-13 1.1990E-18 8.4950E+06 3.0513E+14 Xe-133 1.5004E-11 8.0158E-20 3.6295E+05 1.1012E+16 Control Room Transport Group Inventory:

Time (h) = 32.0000 Atmosphere Sump Noble gases (atoms) 8.8684E+06 0.0000E+00 Elemental I (atoms) 1.3457E+03 0.0000E+00 Organic I (atoms) 1.0152E+03 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 2.2300E-23 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 2.2364E-23 Total I (Ci) 6.5301E-14 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 32.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 5.4658E+19 Elemental I (atoms) 0.0000E+00 9.0090E+15

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 164 Organic I (atoms) 0.0000E+00 6.7963E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 32.0000 Filtered Transported Noble gases (atoms) 5.4654E+19 0.0000E+00 Elemental I (atoms) 8.9825E+15 0.0000E+00 Organic I (atoms) 6.7763E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 104.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.3717E-02 8.2487E+00 2.8508E-01 Low Population Zone Doses:

Time (h) = 104.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.7673E-03 9.2164E-01 3.1852E-02 Control Room Doses:

Time (h) = 104.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.6335E-15 1.6349E-11 5.0055E-13 Accumulated dose (rem) 2.7513E-02 1.6132E+02 4.9431E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 104.0000 Ci kg Atoms Decay Control Room Transport Group Inventory:

Time (h) = 104.0000 Atmosphere Sump Noble gases (atoms) 5.1240E-33 0.0000E+00 Elemental I (atoms) 6.0726E-37 0.0000E+00 Organic I (atoms) 4.5811E-37 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 1.0048E-62 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 1.0051E-62 Total I (Ci) 2.8818E-53 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 104.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 5.4658E+19 Elemental I (atoms) 0.0000E+00 9.0090E+15 Organic I (atoms) 0.0000E+00 6.7963E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 104.0000 Filtered Transported Noble gases (atoms) 5.4654E+19 0.0000E+00 Elemental I (atoms) 8.9825E+15 0.0000E+00 Organic I (atoms) 6.7763E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 728.0000 Whole Body Thyroid TEDE

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 165 Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.3717E-02 8.2487E+00 2.8508E-01 Low Population Zone Doses:

Time (h) = 728.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.7673E-03 9.2164E-01 3.1852E-02 Control Room Doses:

Time (h) = 728.0000 Whole Body Thyroid TEDE Delta dose (rem) 6.9477E-55 4.9113E-51 1.5022E-52 Accumulated dose (rem) 2.7513E-02 1.6132E+02 4.9431E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 728.0000 Ci kg Atoms Decay Control Room Transport Group Inventory:

Time (h) = 728.0000 Atmosphere Sump Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 0.0000E+00 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 0.0000E+00 Total I (Ci) 0.0000E+00 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 728.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 5.4658E+19 Elemental I (atoms) 0.0000E+00 9.0090E+15 Organic I (atoms) 0.0000E+00 6.7963E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 728.0000 Filtered Transported Noble gases (atoms) 5.4654E+19 0.0000E+00 Elemental I (atoms) 8.9825E+15 0.0000E+00 Organic I (atoms) 6.7763E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 838 I-131 Summary Reactor Building Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 8.000 1.8823E+01 1.2044E-02 4.2249E-05 8.004 1.2154E+02 5.0456E-01 1.7676E-03 8.400 4.8712E+01 7.3211E+01 1.9452E-01 8.700 2.4384E+01 9.7496E+01 2.0283E-01 9.000 1.2206E+01 1.0965E+02 1.7383E-01 9.300 6.1099E+00 1.1574E+02 1.3658E-01 9.600 3.0585E+00 1.1878E+02 1.0235E-01 9.900 1.5310E+00 1.2031E+02 7.4532E-02 10.000 1.2156E+00 1.2062E+02 6.6755E-02 10.300 1.2143E+00 1.2062E+02 4.5767E-02

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 166 10.600 1.2130E+00 1.2062E+02 3.1377E-02 10.900 1.2117E+00 1.2062E+02 2.1512E-02 11.200 1.2104E+00 1.2062E+02 1.4748E-02 11.500 1.2091E+00 1.2062E+02 1.0111E-02 11.800 1.2078E+00 1.2062E+02 6.9323E-03 12.100 1.2065E+00 1.2062E+02 4.7527E-03 12.400 1.2052E+00 1.2062E+02 3.2584E-03 12.700 1.2039E+00 1.2062E+02 2.2340E-03 13.000 1.2026E+00 1.2062E+02 1.5316E-03 13.300 1.2013E+00 1.2062E+02 1.0500E-03 13.600 1.2000E+00 1.2062E+02 7.1990E-04 13.900 1.1987E+00 1.2062E+02 4.9355E-04 14.200 1.1974E+00 1.2062E+02 3.3838E-04 14.500 1.1961E+00 1.2062E+02 2.3199E-04 14.800 1.1948E+00 1.2062E+02 1.5905E-04 15.100 1.1935E+00 1.2062E+02 1.0904E-04 15.400 1.1923E+00 1.2062E+02 7.4759E-05 15.700 1.1910E+00 1.2062E+02 5.1254E-05 16.000 1.1897E+00 1.2062E+02 3.5139E-05 16.300 1.1884E+00 1.2062E+02 2.4091E-05 16.600 1.1871E+00 1.2062E+02 1.6517E-05 16.900 1.1858E+00 1.2062E+02 1.1324E-05 17.200 1.1846E+00 1.2062E+02 7.7634E-06 17.500 1.1833E+00 1.2062E+02 5.3225E-06 17.800 1.1820E+00 1.2062E+02 3.6491E-06 18.100 1.1807E+00 1.2062E+02 2.5018E-06 18.400 1.1795E+00 1.2062E+02 1.7152E-06 32.000 1.1232E+00 1.2062E+02 6.3474E-14 104.000 8.6726E-01 1.2062E+02 2.8721E-53 728.000 9.2187E-02 1.2062E+02 0.0000E+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone Control Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 8.000 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 8.004 3.4496E-02 1.1925E-03 3.8544E-03 1.3324E-04 1.1925E-03 3.6543E-05 8.400 5.0068E+00 1.7307E-01 5.5942E-01 1.9337E-02 2.3517E+01 7.2067E-01 8.700 6.6675E+00 2.3045E-01 7.4497E-01 2.5749E-02 5.2826E+01 1.6188E+00 9.000 7.4987E+00 2.5917E-01 8.3784E-01 2.8958E-02 8.0179E+01 2.4569E+00 9.300 7.9147E+00 2.7354E-01 8.8432E-01 3.0563E-02 1.0256E+02 3.1429E+00 9.600 8.1229E+00 2.8073E-01 9.0759E-01 3.1367E-02 1.1973E+02 3.6688E+00 9.900 8.2272E+00 2.8433E-01 9.1924E-01 3.1769E-02 1.3241E+02 4.0572E+00 10.000 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.3580E+02 4.1612E+00 10.300 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.4383E+02 4.4071E+00 10.600 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.4933E+02 4.5757E+00 10.900 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.5310E+02 4.6913E+00 11.200 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.5569E+02 4.7705E+00 11.500 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.5746E+02 4.8248E+00 11.800 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.5867E+02 4.8620E+00 12.100 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.5951E+02 4.8875E+00 12.400 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6008E+02 4.9050E+00 12.700 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6047E+02 4.9170E+00 13.000 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6074E+02 4.9252E+00 13.300 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6092E+02 4.9309E+00 13.600 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6105E+02 4.9347E+00 13.900 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6114E+02 4.9374E+00 14.200 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6119E+02 4.9392E+00 14.500 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6123E+02 4.9404E+00 14.800 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6126E+02 4.9413E+00 15.100 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6128E+02 4.9419E+00 15.400 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6130E+02 4.9423E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 167 15.700 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6130E+02 4.9425E+00 16.000 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6131E+02 4.9427E+00 16.300 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6131E+02 4.9429E+00 16.600 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6132E+02 4.9430E+00 16.900 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6132E+02 4.9430E+00 17.200 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6132E+02 4.9431E+00 17.500 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6132E+02 4.9431E+00 17.800 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6132E+02 4.9431E+00 18.100 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6132E+02 4.9431E+00 18.400 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6132E+02 4.9431E+00 32.000 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6132E+02 4.9431E+00 104.000 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6132E+02 4.9431E+00 728.000 8.2487E+00 2.8508E-01 9.2164E-01 3.1852E-02 1.6132E+02 4.9431E+00 Worst Two-Hour Doses Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 8.0 3.3717E-02 8.2487E+00 2.8508E-01

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 168 NF-500_GNF3_104.o0 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:37:25 File information Plant file = D:\\Staum\\Fitz\\FHA\\104 hr\\NF-500_GNF3_104.psf Inventory file = d:\\staum\\fitz\\fha\\jfha_source_96.nif Release file = d:\\staum\\fitz\\fha\\jafha_rft_with_df.rft Dose Conversion file = d:\\staum\\fitz\\fha\\jafha_fg11&12.inp Radtrad 3.03 4/15/2001 JAF FHA Occurring In Reactor Bldg With RB Vent Release, Pool DF = 200, Peaking Factor =

1.82, Decay Time = 96 Hrs, CR Normal Flow Rate =2,112 cfm, No SGTS Filtration, and Plant Vent Release @ 99,800 cfm Nuclide Inventory File:

d:\\staum\\fitz\\fha\\jfha_source_96.nif Plant Power Level:

1.5027E+01 Compartments:

3 Compartment 1:

Reactor Building 3

2.6000E+06 0

0 0

0 0

Compartment 2:

Environment 2

0.0000E+00 0

0 0

0 0

Compartment 3:

Control Room 1

1.0100E+05 0

0 0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 169 0

0 Pathways:

3 Pathway 1:

Reactor Building to Environment 1

2 2

Pathway 2:

CR Air Intake 2

3 2

Pathway 3:

CR Exhaust to Environment 3

2 2

End of Plant Model File Scenario Description Name:

Plant Model Filename:

Source Term:

1 1 1.0000E+00 d:\\staum\\fitz\\fha\\jafha_fg11&12.inp d:\\staum\\fitz\\fha\\jafha_rft_with_df.rft 8.0000E+00 1

0.0000E+00 5.7000E-01 4.3000E-01 1.0000E+00 Overlying Pool:

0 0.0000E+00 0

0 0

0 Compartments:

3 Compartment 1:

0 1

0 0

0 0

0 0

0 Compartment 2:

0 1

0 0

0 0

0 0

0 Compartment 3:

1 1

0

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 170 0

0 0

0 0

0 Pathways:

3 Pathway 1:

0 0

0 0

0 1

3 8.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 1.0000E+01 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2800E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 2:

0 0

0 0

0 1

2 8.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2800E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Pathway 3:

0 0

0 0

0 1

2 8.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2800E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 0

0 0

0 0

0 Dose Locations:

3 Location 1:

Exclusion Area Boundary 2

1 2

8.0000E+00 1.7900E-04

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 171 7.2800E+02 0.0000E+00 1

2 8.0000E+00 3.5000E-04 7.2800E+02 0.0000E+00 0

Location 2:

Low Population Zone 2

1 5

8.0000E+00 2.0000E-05 1.6000E+01 1.3400E-05 3.2000E+01 5.5900E-06 1.0400E+02 1.6000E-06 7.2800E+02 0.0000E+00 1

4 8.0000E+00 3.5000E-04 1.6000E+01 1.8000E-04 3.2000E+01 2.3000E-04 7.2800E+02 0.0000E+00 0

Location 3:

Control Room 3

0 1

2 8.0000E+00 3.5000E-04 7.2800E+02 0.0000E+00 1

4 8.0000E+00 1.0000E+00 3.2000E+01 6.0000E-01 1.0400E+02 4.0000E-01 7.2800E+02 0.0000E+00 Effective Volume Location:

1 6

8.0000E+00 3.5200E-03 1.0000E+01 3.3100E-03 1.6000E+01 1.4300E-03 3.2000E+01 7.7300E-04 1.0400E+02 6.0700E-04 7.2800E+02 0.0000E+00 Simulation Parameters:

6 8.0000E+00 1.0000E-01 1.0000E+01 5.0000E-01 1.6000E+01 1.0000E+00 3.2000E+01 2.0000E+00 1.0400E+02 4.0000E+00 7.2800E+02 0.0000E+00 Output Filename:

D:\\Staum\\Fitz\\FHA\\104 hr\\NF-500_GNF3_104.o0 1

1 1

0 0

End of Scenario File

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 172 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:37:25 Plant Description Number of Nuclides = 60 Inventory Power = 1.0000E+00 MWth Plant Power Level = 1.5027E+01 MWth Number of compartments = 3 Compartment information Compartment number 1 (Source term fraction = 1.0000E+00

)

Name: Reactor Building Compartment volume = 2.6000E+06 (Cubic feet)

Compartment type is Normal Pathways into and out of compartment 1 Exit Pathway Number 1: Reactor Building to Environment Compartment number 2 Name: Environment Compartment type is Environment Pathways into and out of compartment 2 Inlet Pathway Number 1: Reactor Building to Environment Inlet Pathway Number 3: CR Exhaust to Environment Exit Pathway Number 2: CR Air Intake Compartment number 3 Name: Control Room Compartment volume = 1.0100E+05 (Cubic feet)

Compartment type is Control Room Pathways into and out of compartment 3 Inlet Pathway Number 2: CR Air Intake Exit Pathway Number 3: CR Exhaust to Environment Total number of pathways = 3 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:37:25 Scenario Description Time between shutdown and first release = 8.0000E+00 (Hours)

Radioactive Decay is enabled Calculation of Daughters is enabled Release Fractions and Timings GAP EARLY IN-VESSEL LATE RELEASE RELEASE MASS 0.003600 hr 0.0000 hrs 0.0000 hrs (gm)

NOBLES 5.0000E-02 0.0000E+00 0.0000E+00 2.179E+00 IODINE 2.5000E-04 0.0000E+00 0.0000E+00 9.789E-04 CESIUM 1.2000E-01 0.0000E+00 0.0000E+00 0.000E+00 TELLURIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 STRONTIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 173 BARIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 RUTHENIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 CERIUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 LANTHANUM 0.0000E+00 0.0000E+00 0.0000E+00 0.000E+00 Inventory Power = 15. MWt Nuclide Group Specific half Whole Body Inhaled Inhaled Name Inventory life DCF Thyroid Effective (Ci/MWt) (s) (Sv-m3/Bq-s) (Sv/Bq) (Sv/Bq)

Kr-83m 1 1.800E-08 6.588E+03 1.500E-18 0.000E+00 0.000E+00 Kr-85 1 1.052E+03 3.383E+08 1.190E-16 0.000E+00 0.000E+00 Kr-85m 1 3.110E-03 1.613E+04 7.480E-15 0.000E+00 0.000E+00 Kr-87 1 3.360E-19 4.578E+03 4.120E-14 0.000E+00 0.000E+00 Kr-88 1 1.570E-06 1.022E+04 1.020E-13 0.000E+00 0.000E+00 Br-83 2 3.840E-09 8.604E+03 3.820E-16 3.290E-12 2.330E-11 I-130 2 3.270E+00 4.450E+04 1.040E-13 1.990E-08 7.140E-10 I-131 2 3.184E+04 6.947E+05 1.820E-14 2.920E-07 8.890E-09 I-132 2 1.700E+04 8.280E+03 1.120E-13 1.740E-09 1.030E-10 I-133 2 2.370E+03 7.488E+04 2.940E-14 4.860E-08 1.580E-09 I-134 2 2.970E-28 3.156E+03 1.300E-13 2.880E-10 3.550E-11 I-135 2 2.130E+00 2.380E+04 8.294E-14 8.460E-09 3.320E-10 Xe-131m 1 3.540E+02 1.028E+06 3.890E-16 0.000E+00 0.000E+00 Xe-133 1 3.980E+04 4.532E+05 1.560E-15 0.000E+00 0.000E+00 Xe-133m 1 7.450E+02 1.890E+05 1.370E-15 0.000E+00 0.000E+00 Xe-135 1 1.050E+02 3.272E+04 1.190E-14 0.000E+00 0.000E+00 Xe-135m 1 3.480E-01 9.174E+02 2.040E-14 0.000E+00 0.000E+00 Nuclide Daughter Fraction Daughter Fraction Daughter Fraction Kr-85m Kr-85 0.21 none 0.00 none 0.00 Kr-87 Rb-87 1.00 none 0.00 none 0.00 Kr-88 Rb-88 1.00 none 0.00 none 0.00 Br-83 Kr-83m 1.00 none 0.00 none 0.00 I-131 Xe-131m 0.01 none 0.00 none 0.00 I-133 Xe-133m 0.03 Xe-133 0.97 none 0.00 I-135 Xe-135m 0.15 Xe-135 0.85 none 0.00 Xe-133m Xe-133 1.00 none 0.00 none 0.00 Xe-135 Cs-135 1.00 none 0.00 none 0.00 Xe-135m Xe-135 1.00 none 0.00 none 0.00 Iodine fractions Aerosol = 0.0000E+00 Elemental = 5.7000E-01 Organic = 4.3000E-01 COMPARTMENT DATA Compartment number 1: Reactor Building Compartment number 2: Environment Compartment number 3: Control Room PATHWAY DATA Pathway number 1: Reactor Building to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 8.0000E+00 9.9800E+04 0.0000E+00 0.0000E+00 0.0000E+00 1.0000E+01 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 7.2800E+02 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 174 Pathway number 2: CR Air Intake Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 8.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2800E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 Pathway number 3: CR Exhaust to Environment Pathway Filter: Removal Data Time (hr) Flow Rate Filter Efficiencies (%)

(cfm) Aerosol Elemental Organic 8.0000E+00 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 7.2800E+02 2.1120E+03 0.0000E+00 0.0000E+00 0.0000E+00 LOCATION DATA Location Exclusion Area Boundary is in compartment 2 Location X/Q Data Time (hr) X/Q (s

  • m^-3) 8.0000E+00 1.7900E-04 7.2800E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 8.0000E+00 3.5000E-04 7.2800E+02 0.0000E+00 Location Low Population Zone is in compartment 2 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 8.0000E+00 2.0000E-05 1.6000E+01 1.3400E-05 3.2000E+01 5.5900E-06 1.0400E+02 1.6000E-06 7.2800E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 8.0000E+00 3.5000E-04 1.6000E+01 1.8000E-04 3.2000E+01 2.3000E-04 7.2800E+02 0.0000E+00 Location Control Room is in compartment 3 Location X/Q Data Time (hr) X/Q (s
  • m^-3) 8.0000E+00 3.5200E-03 1.0000E+01 3.3100E-03 1.6000E+01 1.4300E-03 3.2000E+01 7.7300E-04 1.0400E+02 6.0700E-04 7.2800E+02 0.0000E+00 Location Breathing Rate Data Time (hr) Breathing Rate (m^3
  • sec^-1) 8.0000E+00 3.5000E-04 7.2800E+02 0.0000E+00 Location Occupancy Factor Data Time (hr) Occupancy Factor 8.0000E+00 1.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 175 3.2000E+01 6.0000E-01 1.0400E+02 4.0000E-01 7.2800E+02 0.0000E+00 USER SPECIFIED TIME STEP DATA - SUPPLEMENTAL TIME STEPS Time Time step 0.0000E+00 1.0000E-01 2.0000E+00 5.0000E-01 8.0000E+00 1.0000E+00 2.4000E+01 2.0000E+00 9.6000E+01 4.0000E+00 7.2000E+02 0.0000E+00 RADTRAD Version 3.03 (Spring 2001) run on 5/23/2023 at 15:37:25 Dose, Detailed model and Detailed Inventory Output Exclusion Area Boundary Doses:

Time (h) = 8.0036 Whole Body Thyroid TEDE Delta dose (rem) 1.3457E-04 3.2850E-02 1.1356E-03 Accumulated dose (rem) 1.3457E-04 3.2850E-02 1.1356E-03 Low Population Zone Doses:

Time (h) = 8.0036 Whole Body Thyroid TEDE Delta dose (rem) 1.5035E-05 3.6704E-03 1.2689E-04 Accumulated dose (rem) 1.5035E-05 3.6704E-03 1.2689E-04 Control Room Doses:

Time (h) = 8.0036 Whole Body Thyroid TEDE Delta dose (rem) 1.9487E-07 1.1355E-03 3.4799E-05 Accumulated dose (rem) 1.9487E-07 1.1355E-03 3.4799E-05 Control Room Compartment Nuclide Inventory:

Time (h) = 8.0036 Ci kg Atoms Decay Kr-85 1.1447E-02 2.9177E-08 2.0671E+17 3.8961E+09 Kr-85m 9.8099E-09 1.1920E-18 8.4454E+06 3.3396E+03 I-130 1.1358E-07 5.8234E-17 2.6977E+08 3.8660E+04 I-131 1.6833E-03 1.3578E-11 6.2417E+13 5.7292E+08 I-132 8.2906E-05 8.0319E-15 3.6643E+10 2.8229E+07 I-133 9.8761E-05 8.7182E-14 3.9475E+11 3.3616E+07 I-135 5.0067E-08 1.4257E-17 6.3596E+07 1.7043E+04 Xe-131m 3.8503E-03 4.5968E-11 2.1132E+14 1.3105E+09 Xe-133 4.1570E-01 2.2208E-09 1.0056E+16 1.4149E+11 Xe-133m 7.3598E-03 1.6402E-11 7.4269E+13 2.5050E+09

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 176 Xe-135 6.2757E-04 2.4575E-13 1.0962E+12 2.1362E+08 Xe-135m 1.7327E-06 1.9021E-17 8.4849E+07 5.9176E+05 Control Room Transport Group Inventory:

Time (h) = 8.0036 Atmosphere Sump Noble gases (atoms) 2.1705E+17 0.0000E+00 Elemental I (atoms) 3.5824E+13 0.0000E+00 Organic I (atoms) 2.7025E+13 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 5.9448E-13 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 5.9884E-13 Total I (Ci) 1.8650E-03 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 8.0036 Filtered Transported Noble gases (atoms) 0.0000E+00 2.1738E+17 Elemental I (atoms) 0.0000E+00 3.5878E+13 Organic I (atoms) 0.0000E+00 2.7066E+13 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 8.0036 Filtered Transported Noble gases (atoms) 3.2706E+14 0.0000E+00 Elemental I (atoms) 5.3981E+10 0.0000E+00 Organic I (atoms) 4.0722E+10 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 10.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.1974E-02 7.8222E+00 2.7034E-01 Accumulated dose (rem) 3.2108E-02 7.8551E+00 2.7147E-01 Low Population Zone Doses:

Time (h) = 10.0000 Whole Body Thyroid TEDE Delta dose (rem) 3.5725E-03 8.7399E-01 3.0205E-02 Accumulated dose (rem) 3.5875E-03 8.7766E-01 3.0332E-02 Control Room Doses:

Time (h) = 10.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.2085E-02 1.2932E+02 3.9626E+00 Accumulated dose (rem) 2.2085E-02 1.2932E+02 3.9627E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 10.0000 Ci kg Atoms Decay Kr-85 4.3540E-01 1.1098E-06 7.8626E+18 2.4718E+14 Kr-85m 2.7399E-07 3.3293E-17 2.3588E+08 1.8554E+08 Kr-88 5.6604E-11 4.5141E-21 3.0892E+04 4.2556E+04 I-130 3.8626E-06 1.9805E-15 9.1743E+09 2.3359E+09 I-131 6.3570E-02 5.1277E-10 2.3572E+15 3.6235E+13 I-132 1.7278E-03 1.6739E-13 7.6368E+11 1.3906E+12 I-133 3.5148E-03 3.1027E-12 1.4049E+13 2.0715E+12 I-135 1.5447E-06 4.3985E-16 1.9621E+09 9.8760E+08 Xe-131m 1.4575E-01 1.7401E-09 7.9992E+15 8.2967E+13 Xe-133 1.5642E+01 8.3568E-08 3.7839E+17 8.9342E+15 Xe-133m 2.7267E-01 6.0768E-10 2.7515E+15 1.5710E+14 Xe-135 2.0502E-02 8.0282E-12 3.5813E+13 1.2686E+13 Xe-135m 5.6277E-07 6.1780E-18 2.7559E+07 7.4102E+09

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 177 Control Room Transport Group Inventory:

Time (h) = 10.0000 Atmosphere Sump Noble gases (atoms) 8.2518E+18 0.0000E+00 Elemental I (atoms) 1.3521E+15 0.0000E+00 Organic I (atoms) 1.0200E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 2.2435E-11 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 2.2578E-11 Total I (Ci) 6.8814E-02 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 10.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 5.2050E+19 Elemental I (atoms) 0.0000E+00 8.5791E+15 Organic I (atoms) 0.0000E+00 6.4720E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 10.0000 Filtered Transported Noble gases (atoms) 4.3796E+19 0.0000E+00 Elemental I (atoms) 7.2057E+15 0.0000E+00 Organic I (atoms) 5.4359E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 16.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.2108E-02 7.8551E+00 2.7147E-01 Low Population Zone Doses:

Time (h) = 16.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.5875E-03 8.7766E-01 3.0332E-02 Control Room Doses:

Time (h) = 16.0000 Whole Body Thyroid TEDE Delta dose (rem) 4.1128E-03 2.4291E+01 7.4420E-01 Accumulated dose (rem) 2.6198E-02 1.5361E+02 4.7069E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 16.0000 Ci kg Atoms Decay Kr-85 2.3417E-04 5.9687E-10 4.2288E+15 2.9055E+14 Kr-85m 5.8241E-11 7.0771E-21 5.0140E+04 2.0983E+08 I-130 1.4839E-09 7.6085E-19 3.5246E+06 2.7041E+09 I-131 3.3462E-05 2.6991E-13 1.2408E+12 4.2547E+13 I-132 1.5236E-07 1.4761E-17 6.7341E+07 1.5294E+12 I-133 1.5479E-06 1.3664E-15 6.1869E+09 2.4126E+12 I-135 4.4285E-10 1.2610E-19 5.6252E+05 1.1296E+09 Xe-131m 7.7265E-05 9.2244E-13 4.2405E+12 9.7455E+13 Xe-133 8.1445E-03 4.3511E-11 1.9702E+14 1.0485E+16 Xe-133m 1.3549E-04 3.0197E-13 1.3673E+12 1.8398E+14 Xe-135 6.9787E-06 2.7328E-15 1.2190E+10 1.4611E+13 Control Room Transport Group Inventory:

Time (h) = 16.0000 Atmosphere Sump Noble gases (atoms) 4.4314E+15 0.0000E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 178 Elemental I (atoms) 7.1083E+11 0.0000E+00 Organic I (atoms) 5.3624E+11 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 1.1791E-14 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 1.1847E-14 Total I (Ci) 3.5163E-05 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 16.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 5.2050E+19 Elemental I (atoms) 0.0000E+00 8.5791E+15 Organic I (atoms) 0.0000E+00 6.4720E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 16.0000 Filtered Transported Noble gases (atoms) 5.2042E+19 0.0000E+00 Elemental I (atoms) 8.5531E+15 0.0000E+00 Organic I (atoms) 6.4524E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 32.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.2108E-02 7.8551E+00 2.7147E-01 Low Population Zone Doses:

Time (h) = 32.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.5875E-03 8.7766E-01 3.0332E-02 Control Room Doses:

Time (h) = 32.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.1246E-06 1.2776E-02 3.9131E-04 Accumulated dose (rem) 2.6200E-02 1.5363E+02 4.7073E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 32.0000 Ci kg Atoms Decay Kr-85 4.4797E-13 1.1418E-18 8.0896E+06 2.9057E+14 Xe-133 1.4288E-11 7.6333E-20 3.4563E+05 1.0486E+16 Control Room Transport Group Inventory:

Time (h) = 32.0000 Atmosphere Sump Noble gases (atoms) 8.4452E+06 0.0000E+00 Elemental I (atoms) 1.2815E+03 0.0000E+00 Organic I (atoms) 9.6676E+02 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 2.1236E-23 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 2.1297E-23 Total I (Ci) 6.2185E-14 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 32.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 5.2050E+19 Elemental I (atoms) 0.0000E+00 8.5791E+15

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 179 Organic I (atoms) 0.0000E+00 6.4720E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 32.0000 Filtered Transported Noble gases (atoms) 5.2046E+19 0.0000E+00 Elemental I (atoms) 8.5538E+15 0.0000E+00 Organic I (atoms) 6.4529E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 104.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.2108E-02 7.8551E+00 2.7147E-01 Low Population Zone Doses:

Time (h) = 104.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.5875E-03 8.7766E-01 3.0332E-02 Control Room Doses:

Time (h) = 104.0000 Whole Body Thyroid TEDE Delta dose (rem) 2.5079E-15 1.5569E-11 4.7666E-13 Accumulated dose (rem) 2.6200E-02 1.5363E+02 4.7073E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 104.0000 Ci kg Atoms Decay Control Room Transport Group Inventory:

Time (h) = 104.0000 Atmosphere Sump Noble gases (atoms) 4.8795E-33 0.0000E+00 Elemental I (atoms) 5.7828E-37 0.0000E+00 Organic I (atoms) 4.3624E-37 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 9.5683E-63 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 9.5716E-63 Total I (Ci) 2.7442E-53 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 104.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 5.2050E+19 Elemental I (atoms) 0.0000E+00 8.5791E+15 Organic I (atoms) 0.0000E+00 6.4720E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 104.0000 Filtered Transported Noble gases (atoms) 5.2046E+19 0.0000E+00 Elemental I (atoms) 8.5538E+15 0.0000E+00 Organic I (atoms) 6.4529E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Exclusion Area Boundary Doses:

Time (h) = 728.0000 Whole Body Thyroid TEDE

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 180 Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.2108E-02 7.8551E+00 2.7147E-01 Low Population Zone Doses:

Time (h) = 728.0000 Whole Body Thyroid TEDE Delta dose (rem) 0.0000E+00 0.0000E+00 0.0000E+00 Accumulated dose (rem) 3.5875E-03 8.7766E-01 3.0332E-02 Control Room Doses:

Time (h) = 728.0000 Whole Body Thyroid TEDE Delta dose (rem) 6.6162E-55 4.6769E-51 1.4306E-52 Accumulated dose (rem) 2.6200E-02 1.5363E+02 4.7073E+00 Control Room Compartment Nuclide Inventory:

Time (h) = 728.0000 Ci kg Atoms Decay Control Room Transport Group Inventory:

Time (h) = 728.0000 Atmosphere Sump Noble gases (atoms) 0.0000E+00 0.0000E+00 Elemental I (atoms) 0.0000E+00 0.0000E+00 Organic I (atoms) 0.0000E+00 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 Dose Effective (Ci/cc) I-131 (Thyroid) 0.0000E+00 Dose Effective (Ci/cc) I-131 (ICRP2 Thyroid) 0.0000E+00 Total I (Ci) 0.0000E+00 CR Air Intake Transport Group Inventory:

Pathway Time (h) = 728.0000 Filtered Transported Noble gases (atoms) 0.0000E+00 5.2050E+19 Elemental I (atoms) 0.0000E+00 8.5791E+15 Organic I (atoms) 0.0000E+00 6.4720E+15 Aerosols (kg) 0.0000E+00 0.0000E+00 CR Exhaust to Environment Transport Group Inventory:

Pathway Time (h) = 728.0000 Filtered Transported Noble gases (atoms) 5.2046E+19 0.0000E+00 Elemental I (atoms) 8.5538E+15 0.0000E+00 Organic I (atoms) 6.4529E+15 0.0000E+00 Aerosols (kg) 0.0000E+00 0.0000E+00 838 I-131 Summary Reactor Building Environment Control Room Time (hr) I-131 (Curies) I-131 (Curies) I-131 (Curies) 8.000 1.7925E+01 1.1470E-02 4.0233E-05 8.004 1.1574E+02 4.8049E-01 1.6833E-03 8.400 4.6387E+01 6.9717E+01 1.8524E-01 8.700 2.3220E+01 9.2844E+01 1.9315E-01 9.000 1.1623E+01 1.0442E+02 1.6553E-01 9.300 5.8184E+00 1.1022E+02 1.3006E-01 9.600 2.9125E+00 1.1312E+02 9.7466E-02 9.900 1.4579E+00 1.1457E+02 7.0975E-02 10.000 1.1576E+00 1.1487E+02 6.3570E-02 10.300 1.1564E+00 1.1487E+02 4.3583E-02

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 181 10.600 1.1551E+00 1.1487E+02 2.9880E-02 10.900 1.1539E+00 1.1487E+02 2.0486E-02 11.200 1.1526E+00 1.1487E+02 1.4045E-02 11.500 1.1514E+00 1.1487E+02 9.6289E-03 11.800 1.1501E+00 1.1487E+02 6.6015E-03 12.100 1.1489E+00 1.1487E+02 4.5259E-03 12.400 1.1477E+00 1.1487E+02 3.1029E-03 12.700 1.1464E+00 1.1487E+02 2.1274E-03 13.000 1.1452E+00 1.1487E+02 1.4585E-03 13.300 1.1440E+00 1.1487E+02 9.9993E-04 13.600 1.1427E+00 1.1487E+02 6.8554E-04 13.900 1.1415E+00 1.1487E+02 4.7000E-04 14.200 1.1403E+00 1.1487E+02 3.2223E-04 14.500 1.1390E+00 1.1487E+02 2.2092E-04 14.800 1.1378E+00 1.1487E+02 1.5146E-04 15.100 1.1366E+00 1.1487E+02 1.0384E-04 15.400 1.1354E+00 1.1487E+02 7.1191E-05 15.700 1.1341E+00 1.1487E+02 4.8808E-05 16.000 1.1329E+00 1.1487E+02 3.3462E-05 16.300 1.1317E+00 1.1487E+02 2.2942E-05 16.600 1.1305E+00 1.1487E+02 1.5729E-05 16.900 1.1293E+00 1.1487E+02 1.0783E-05 17.200 1.1280E+00 1.1487E+02 7.3930E-06 17.500 1.1268E+00 1.1487E+02 5.0685E-06 17.800 1.1256E+00 1.1487E+02 3.4750E-06 18.100 1.1244E+00 1.1487E+02 2.3824E-06 18.400 1.1232E+00 1.1487E+02 1.6333E-06 32.000 1.0696E+00 1.1487E+02 6.0445E-14 104.000 8.2587E-01 1.1487E+02 2.7350E-53 728.000 8.7788E-02 1.1487E+02 0.0000E+00 Cumulative Dose Summary Exclusion Area Bounda Low Population Zone Control Room Time Thyroid TEDE Thyroid TEDE Thyroid TEDE (hr) (rem) (rem) (rem) (rem) (rem) (rem) 8.000 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 0.0000E+00 8.004 3.2850E-02 1.1356E-03 3.6704E-03 1.2689E-04 1.1355E-03 3.4799E-05 8.400 4.7679E+00 1.6481E-01 5.3273E-01 1.8414E-02 2.2395E+01 6.8628E-01 8.700 6.3493E+00 2.1946E-01 7.0942E-01 2.4520E-02 5.0305E+01 1.5415E+00 9.000 7.1408E+00 2.4680E-01 7.9786E-01 2.7576E-02 7.6353E+01 2.3397E+00 9.300 7.5370E+00 2.6049E-01 8.4213E-01 2.9105E-02 9.7670E+01 2.9929E+00 9.600 7.7353E+00 2.6734E-01 8.6428E-01 2.9870E-02 1.1402E+02 3.4937E+00 9.900 7.8346E+00 2.7076E-01 8.7537E-01 3.0253E-02 1.2609E+02 3.8636E+00 10.000 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.2932E+02 3.9627E+00 10.300 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.3696E+02 4.1968E+00 10.600 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.4220E+02 4.3574E+00 10.900 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.4580E+02 4.4674E+00 11.200 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.4826E+02 4.5428E+00 11.500 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.4995E+02 4.5945E+00 11.800 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5110E+02 4.6300E+00 12.100 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5190E+02 4.6543E+00 12.400 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5244E+02 4.6710E+00 12.700 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5281E+02 4.6824E+00 13.000 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5307E+02 4.6902E+00 13.300 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5324E+02 4.6956E+00 13.600 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5336E+02 4.6992E+00 13.900 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5345E+02 4.7018E+00 14.200 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5350E+02 4.7035E+00 14.500 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5354E+02 4.7047E+00 14.800 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5357E+02 4.7055E+00 15.100 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5359E+02 4.7061E+00 15.400 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5360E+02 4.7064E+00

CALCULATION NO. JAF-CALC-RAD-04410 REV. No. 4 PAGE NO. 182 15.700 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5361E+02 4.7067E+00 16.000 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5361E+02 4.7069E+00 16.300 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5362E+02 4.7070E+00 16.600 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5362E+02 4.7071E+00 16.900 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5362E+02 4.7071E+00 17.200 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5362E+02 4.7072E+00 17.500 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5362E+02 4.7072E+00 17.800 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5362E+02 4.7072E+00 18.100 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5362E+02 4.7072E+00 18.400 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5362E+02 4.7072E+00 32.000 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5363E+02 4.7073E+00 104.000 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5363E+02 4.7073E+00 728.000 7.8551E+00 2.7147E-01 8.7766E-01 3.0332E-02 1.5363E+02 4.7073E+00 Worst Two-Hour Doses Exclusion Area Boundary Time Whole Body Thyroid TEDE (hr) (rem) (rem) (rem) 8.0 3.2108E-02 7.8551E+00 2.7147E-01