Form 4.1-PWR Pressurized-Water Reactor Examination Outline Facility:

Byron Station, Units 1 and 2 K/A Catalog Rev. 3 Rev.

0 Date of Exam:

12/22/2022 Tier Group RO K/A Category Points SRO-Only Points K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G*

Total A2 G*

Total

1.

Emergency and Abnormal Plant Evolutions 1

3 3

3 3

3 3

18 3

3 6

2 2

1 1

1 2

1 8

2 2

4 Tier Totals 5

4 4

4 5

4 26 5

5 10

2.

Plant Systems 1

2 3

2 3

2 3

3 3

2 2

3 28 2

3 5

2 1

0 1

1 1

0 1

1 1

1 1

9 0

1 2

3 Tier Totals 3

3 3

4 3

3 4

4 3

3 4

37 3

5 8

3.

Generic Knowledge and Abilities Categories CO EC RC EM 6

CO EC RC EM 7

2 2

1 1

2 2

1 2

4. Theory Reactor Theory Thermodynamics 6

3 3

Notes:

CO = Conduct of Operations; EC = Equipment Control; RC = Radiation Control; EM = Emergency Procedures/Plan

ES-4.1-PWR PWR Examination Outline (Byron)

Emergency and Abnormal Plant EvolutionsTier 1/Group 1 (RO/SRO)

Item E/APE # / Name /

Safety Function K1 K2 K3 A1 A2 G

K/A Topic(s)

IR Q#

1 (000007) (EPE 7)

Reactor Trip X

(000007EK2.17) Knowledge of the relationship between a (EPE 7) Reactor Trip and the following systems or components (CFR: 41.7 / 45.7): SGS 3.6 1

2 (000009) (EPE 9)

Small-Break LOCA X

(000009EK3.04) Knowledge of the reasons for the following responses and/or actions as they apply to a (EPE

9) Small-Break LOCA (CFR: 41.5 / 41.10 / 45.6 / 45.13):

Starting additional charging pumps 3.7 2

3 (000011) (EPE 11)

Large Break LOCA X

(000011) (EPE 11) Large Break LOCA (G2.4.29)

EMERGENCY PROCEDURES/PLAN: Knowledge of the emergency plan implementing procedures (CFR: 41.10 /

43.5 / 45.11) 3.1 3

4 (000022) (APE 22)

Loss of Reactor Coolant Makeup X

(000022AA2.07) Ability to determine and/or interpret the following as they apply to (APE 22) Loss of Reactor Coolant Makeup (CFR: 41.10 / 43.5 / 45.13): VCT level 3.8 4

5 (000025) (APE 25)

Loss of Residual Heat Removal System X

(000025AA1.20) Ability to operate and/or monitor the following as they apply to the (APE 25) Loss of the Residual Heat Removal System (CFR: 41.7 / 45.5 / 45.6):

ECCS 3.7 5

6 (000026) (APE 26)

Loss of Component Cooling Water X

(000026AK1.03) Knowledge of the operational implications and/or cause and effect relationships of the following concepts as they apply to (APE 26) Loss of Component Cooling Water (CFR: 41.5 / 41.7 / 45.7 / 45.8): Loss of CCWS to CVCS charging pumps and/or letdown heat exchanger 3.7 6

7 (000027) (APE 27)

Pressurizer Pressure Control System Malfunction X

(000027) (APE 27) Pressurizer Pressure Control System Malfunction (G2.2.39) EQUIPMENT CONTROL:

Knowledge of less than or equal to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> TS action statements (does not include action statements of 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or less that follow the expiration of a completion time for a TS condition for which an action statement has already been entered) (CFR: 41.7 / 41.10 / 43.2 / 45.13) 3.9 7

8 (000029) (EPE 29)

Anticipated Transient Without Scram X

(000029EA2.09) Ability to determine and/or interpret the following as they apply to an (EPE 29) Anticipated Transient Without Scram (ATWS) (CFR: 41.10 / 43.5 /

45.13): Occurrence of a main turbine trip 4.1 8

9 (000040) (APE 40; W E12) Steam Line Rupture - Excessive Heat Transfer X

(000040AK1.12) Knowledge of the operational implications and/or cause and effect relationships of the following as they apply to a (APE 40) Steam Line Rupture (CFR: 41.8 /

41.10 / 45.3): Normal operating steam parameters as a function of power 3.5 9

10 (000054) (APE 54)

Loss of Main Feedwater X

(000054AA2.09) Ability to determine and/or interpret the following as they apply to (APE 54) Loss of Main Feedwater (CFR: 41.10 / 43.5 / 45.13): S/G dryout conditions 4.1 10 11 (000055) (EPE 55)

Station Blackout X

(000055EK3.01) Knowledge of the reasons for the following responses and/or actions as they apply to a (EPE

55) Station Blackout (CFR: 41.5 / 41.10 / 45.6 / 45.13):

Length of time for which battery capacity is designed 4.1 11 12 (000056) (APE 56)

Loss of Offsite Power X

(000056AK3.02) Knowledge of the reasons for the following responses and/or actions as they apply to (APE

56) Loss of Offsite Power (CFR: 41.5 / 41.10 / 45.6 /

45.13): Actions contained in AOPs 4.1 12

13 (000057) (APE 57)

Loss of Vital AC Instrument Bus X

(000057AK1.01) Knowledge of the operational implications and/or cause and effect relationships of the following concepts as they apply to (APE 57) Loss of Vital AC Electrical Instrument Bus (CFR: 41.8 / 41.10 / 45.3): Effect of a loss of power to instruments powered by a vital instrument bus on plant operation 4.3 13 14 (000058) (APE 58)

Loss of DC Power X

(000058AK2.04) Knowledge of the relationship between (APE 58) Loss of DC Power and the following systems or components (CFR: 41.7 / 45.7): Battery charger 3.6 14 15 (000065) (APE 65)

Loss of Instrument Air X

(000065AK2.15) Knowledge of the relationship between (APE 65) Loss of Instrument Air and the following systems or components (CFR: 41.7 / 45.7): MFW 3.4 15 16 (000077) (APE 77)

Generator Voltage and Electric Grid Disturbances X

(000077AA1.02) Ability to operate and/or monitor the following as they apply to (APE 77) Generator Voltage and Electric Grid Disturbances (CFR: 41.5 / 41.10 / 45.5 / 45.7

/ 45.8): Turbine/generator controls 3.6 16 17 (W E11) Loss of Emergency Coolant Recirculation X

(W E11) Loss of Emergency Coolant Recirculation (G2.2.41) EQUIPMENT CONTROL: Ability to obtain and interpret station electrical and mechanical drawings (reference potential) (CFR: 41.10 / 45.12 / 45.13) 3.5 17 18 (W E05) Inadequate Heat Transfer - Loss of Secondary Heat Sink X

(WE05EA1.07) Ability to operate and/or monitor the following as they apply to (W E05) Loss of Secondary Heat Sink (CFR: 41.5 to 41.8 / 45.5 to 45.8): ITM 3.7 18 19 (000008) (APE 8)

Pressurizer Vapor Space Accident X

(000008AA2.32) Ability to determine and/or interpret the following as they apply to a (APE 8) Pressurizer Vapor Space Accident (CFR: 43.5 / 45.13): PRT/quench tank level, pressure, and temperature 3.5 76 20 (000015) (APE 15)

Reactor Coolant Pump Malfunctions X

(000015AA2.10) Ability to determine and/or interpret the following as they apply to (APE 15) Reactor Coolant Pump Malfunctions (CFR: 43.5 / 45.13): Loss of cooling or seal injection 3.8 77 21 (000038) (EPE 38)

Steam Generator Tube Rupture X

(000038) (EPE 38) Steam Generator Tube Rupture (G2.1.39) CONDUCT OF OPERATIONS: Knowledge of conservative decision-making practices (CFR: 41.10 /

43.5 / 45.12) 4.3 78 22 (000062) (APE 62)

Loss of Service Water X

(000062) (APE 62) Loss of Service Water (G2.4.45)

EMERGENCY PROCEDURES/PLAN: Ability to prioritize and interpret the significance of each annunciator or alarm (CFR: 41.10 / 43.5 / 45.3 / 45.12) 4.3 79 23 (W E04) LOCA Outside Containment X

(W E04) LOCA Outside Containment (G2.3.12)

RADIATION CONTROL: Knowledge of radiological safety principles and procedures pertaining to licensed operator duties, such as response to radiation monitor alarms, containment entry requirements, fuel handling responsibilities, access to locked high-radiation areas, or alignment of filters (CFR: 41.12 / 43.4 / 45.9 / 45.10) 3.7 80 24 (W E05) Inadequate Heat Transfer -

Loss of Secondary Heat Sink X

(W E05 EA2.03) Ability to determine and/or interpret the following as they apply to (W E05) Loss of Secondary Heat Sink (CFR: 41.10 / 43.5 / 45.13): Feed flow to S/Gs 4.3 81 K/A Category Totals:

3 3

3 3

3/3 3/3 Group Point Total:

18/6

ES-4.1-PWR PWR Examination Outline (Byron)

Emergency and Abnormal Plant EvolutionsTier 1/Group 2 (RO/SRO)

Item E/APE # / Name /

Safety Function K1 K2 K3 A1 A2 G

K/A Topic(s)

IR Q#

25 (000003) (APE 3)

Dropped Control Rod X

(000003AK1.23) Knowledge of the operational implications and/or cause and effect relationships of the following concepts as they apply to (APE 3) Dropped Control Rod (CFR: 41.8 / 41.10 / 45.3): Multiple rod drops 4.1 19 26 (000032) (APE 32)

Loss of Source Range Nuclear Instrumentation X

(000032AA1.02) Ability to operate and/or monitor the following as they apply to (APE 32) Loss of Source Range Nuclear Instrumentation (CFR: 41.7 / 45.5 / 45.6): RPS 3.7 20 27 (000037) (APE 37)

Steam Generator Tube Leak X

(000037AK3.14) Knowledge of the reasons for the following responses and/or actions as they apply to (APE

37) Steam Generator Tube Leak (CFR: 41.5 / 41.7 / 41.10

/ 45.6 / 45.13): Isolation of effected S/G 4.3 21 28 (000059) (APE 59)

Accidental Liquid Radwaste Release X

(000059AA2.03) Ability to determine and/or interpret the following as they apply to an (APE 59) Accidental Liquid Radwaste Release (CFR: 41.10 / 43.5 / 45.13): Failure modes, symptoms, and/or indications of a radioactive-liquid monitor failure 3.2 22 29 (000061) (APE 61)

Area Radiation Monitoring System Alarms X

(000061AK1.02) Knowledge of the operational implications and/or cause and effect relationships of the following concepts as they apply to (APE 61) Area Radiation Monitoring (ARM) System Alarms (CFR: 41.8 /

41.10 / 45.3): Adverse containment conditions 3.6 23 30 (000068) (APE 68)

Control Room Evacuation X

(000068) (APE 68) Control Room Evacuation (G2.1.21)

CONDUCT OF OPERATIONS: Ability to verify that a copy of a controlled procedure is the proper revision (CFR:

41.10 / 45.10 / 45.13) 3.5 24 31 (W E15)

Containment Flooding X

(WE15EA2.03) Ability to determine and/or interpret the following as they apply to (W E15) Containment Flooding (CFR: 41.10 / 43.5 / 45.13): Containment sump water level 3.0 25 32 (W E09 & E10)

Natural Circulation X

(WE09EK2.05) Knowledge of the relationship between (W E09) Natural Circulation Operations and the following systems or components (CFR: 41.7 / 41.8 / 45.2 / 45.4):

RVLIS 3.8 26 33 (000005) (APE 5)

Inoperable/Stuck Control Rod X

(000005) (APE 5) Inoperable/Stuck Control Rod (G2.4.20) EMERGENCY PROCEDURES/PLAN:

Knowledge of the operational implications of emergency and abnormal operating procedures warnings, cautions, and notes (CFR: 41.10 / 43.5 / 45.13) 4.3 82 34 (W E13) Steam Generator Overpressure X

(WE13.EA2.02) Ability to determine and/or interpret the following as they apply to Steam Generator Overpressure (CFR: 41.10 / 43.5 / 45.13): Adherence to appropriate procedures and operation within the limitations of the facilitys license and amendments 3.9 83 35 (000074) (EPE 74; W E06 & E07)

Inadequate Core Cooling X

(000074EA2.02) Ability to determine and/or interpret the following as they apply to (EPE 74) Inadequate Core Cooling (CFR: 43.5 / 45.13): Availability of MFW or AFW 4.1 84 36 (W E16) High Containment Radiation X

(W E16) High Containment Radiation (G2.4.4)

EMERGENCY PROCEDURES/PLAN: Ability to recognize abnormal indications for system operating parameters that are entry-level conditions for emergency and abnormal operating procedures (CFR: 41.10 / 43.2 / 45.6) 4.7 85 K/A Category Totals:

2 1

1 1

2/2 1/2 Group Point Total:

8/4

ES-4.1-PWR PWR Examination Outline (Byron)

Plant SystemsTier 2/Group 1 (RO/SRO)

Item System / Name K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G

K/A Topic(s)

IR Q#

37 (003) (SF4P RCP)

REACTOR COOLANT PUMP SYSTEM X

(003) (SF4P RCP) REACTOR COOLANT PUMP SYSTEM (G2.4.34) EMERGENCY PROCEDURES/PLAN:

Knowledge of RO responsibilities outside the main control room during an emergency (CFR: 41.10 / 43.5 /

45.13) 4.2 27 38 (003) (SF4P RCP)

REACTOR COOLANT PUMP SYSTEM X

(003K6.08) Knowledge of the effect of the following plant conditions, system malfunctions, or component malfunctions on the (SF4P RCP) REACTOR COOLANT PUMP SYSTEM (CFR: 41.7 / 45.5): Anti-Reverse rotation device 2.8 28 39 (004) (SF1; SF2 CVCS)

CHEMICAL AND VOLUME CONTROL SYSTEM X

(004A2.16) Ability to (a) predict the impacts of the following on the (SF1; SF2 CVCS)

CHEMICAL AND VOLUME CONTROL SYSTEM and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal operations (CFR: 41.5 to 41.7 / 43.5 / 45.3 /

45.5): T-avg. and T-ref.

deviations 3.0 29 40 (004) (SF1; SF2 CVCS)

CHEMICAL AND VOLUME CONTROL SYSTEM X

(004K4.01) Knowledge of (SF1; SF2 CVCS) CHEMICAL AND VOLUME CONTROL SYSTEM design features and/or interlocks that provide for the following (CFR: 41.6 / 41.7):

Oxygen control in RCS 2.9 30 41 (005) (SF4P RHR)

RESIDUAL HEAT REMOVAL SYSTEM X

(005K2.02) Knowledge of electrical power supplies to the following (CFR: 41.7): (SF4P RHR) RESIDUAL HEAT REMOVAL SYSTEM Containment isolation valves 3.3 31 42 (006) (SF2; SF3 ECCS)

EMERGENCY CORE COOLING SYSTEM X

(006K1.14) Knowledge of the physical connections and/or cause and effect relationships between the (SF2; SF3 ECCS)

EMERGENCY CORE COOLING SYSTEM and the following systems (CFR: 41.2 to 41.8 / 45.3 / 45.7 / 45.8):

Instrument Air System (IAS) 3.1 32 43 (007) (SF5 PRTS)

PRESSURIZER RELIEF/QUENCH TANK SYSTEM X

(007A3.01) Ability to monitor automatic features of the (SF5 PRTS) PRESSURIZER RELIEF/QUENCH TANK SYSTEM, including (CFR: 41.5 /

41.7 / 45.5): Components that discharge to the PRT/quench tank 3.4 33

44 (007) (SF5 PRTS)

PRESSURIZER RELIEF/QUENCH TANK SYSTEM X

(007K4.04) Knowledge of (SF5 PRTS) PRESSURIZER RELIEF/QUENCH TANK SYSTEM design features and/or interlocks that provide for the following (CFR: 41.7):

PRT/quench tank rupture disk 3.7 34 45 (008) (SF8 CCW)

COMPONENT COOLING WATER SYSTEM X

(008K3.01) Knowledge of the effect that a loss or malfunction of the (SF8 CCW)

COMPONENT COOLING WATER SYSTEM will have on the following systems or system parameters (CFR: 41.4 to 41.7 /

45.7 to 45.9): Loads cooled by CCWS 4.0 35 46 (010) (SF3 PZR PCS)

PRESSURIZER PRESSURE CONTROL SYSTEM X

(010A2.05) Ability to (a) predict the impacts of the following on the (SF3 PZR PCS)

PRESSURIZER PRESSURE CONTROL SYSTEM and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal operations (CFR: 41.5 / 43.5 / 45.3 / 45.13):

Loss of RCP loop flow to normal spray valves 3.5 36 47 (012) (SF7 RPS)

REACTOR PROTECTION SYSTEM X

(012A4.02) Ability to manually operate and/or monitor the (SF7 RPS) REACTOR PROTECTION SYSTEM in the control room (CFR: 41.7 / 45.5 to 45.8):

Components for individual channels 3.8 37 48 (013) (SF2 ESFAS)

ENGINEERED SAFETY FEATURES ACTUATION SYSTEM X

(013A3.10) Ability to monitor operation of the (SF2 ESFAS)

ENGINEERED SAFETY FEATURES ACTUATION SYSTEM, including (CFR: 41.6 /

41.7 / 41.8 / 45.5): Recirculation actuation/signal 4.2 38 49 (022) (SF5 CCS)

CONTAINMENT COOLING SYSTEM X

(022A1.01) Ability to predict and/or monitor changes in parameters associated with operation of the (SF5 CCS)

CONTAINMENT COOLING SYSTEM, including (CFR: 41.5 /

45.5): Containment temperature 3.8 39 50 (026) (SF5 CSS)

CONTAINMENT SPRAY SYSTEM X

(026K3.01) Knowledge of the effect that a loss or malfunction of the (SF5 CSS)

CONTAINMENT SPRAY SYSTEM will have on the following systems or system parameters (CFR: 41.7 / 45.6):

CCS 3.8 40 51 (039) (SF4S MSS)

MAIN AND REHEAT STEAM SYSTEM X

(039A1.12) Ability to predict and/or monitor changes in parameters associated with operation of the (SF4S MSS)

MAIN AND REHEAT STEAM SYSTEM, including (CFR: 41.5 /

45.5): MT/G temperatures 2.7 41

52 (039) (SF4S MSS)

MAIN AND REHEAT STEAM SYSTEM X

(039A2.06) Ability to (a) predict the impacts of the following on the (SF4S MSS) MAIN AND REHEAT STEAM SYSTEM and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal operations (CFR: 41.5

/ 43.5 / 45.3 / 45.13):

Atmospheric relief valve malfunctions 4.2 42 53 (059) (SF4S MFW) MAIN FEEDWATER SYSTEM X

(059K4.22) Knowledge of (SF4S MFW) MAIN FEEDWATER SYSTEM design features and/or interlocks that provide for the following (CFR: 41.7): S/G water LCS 3.8 43 54 (061) (SF4S AFW)

AUXILIARY /

EMERGENCY FEEDWATER SYSTEM X

(061K2.02) Knowledge of electrical power supplies to the following (CFR: 41.7): (SF4S AFW)

AUXILIARY/EMERGENCY FEEDWATER SYSTEM AFW electric-driven pumps 4.1 44 55 (062) (SF6 ED AC) AC ELECTRICAL DISTRIBUTION SYSTEM X

(062A1.05) Ability to predict and/or monitor changes in parameters associated with operation of the (SF6 ED AC)

AC ELECTRICAL DISTRIBUTION SYSTEM, including (CFR: 41.5 / 45.5):

Bus voltages 3.5 45 56 (062) (SF6 ED AC) AC ELECTRICAL DISTRIBUTION SYSTEM X

(062K5.05) Knowledge of the operational implications or cause and effect relationships of the following concepts as they apply to the (SF6 ED AC) AC ELECTRICAL DISTRIBUTION SYSTEM (CFR: 41.5 / 45.7):

Fault on a bus 3.5 46 57 (063) (SF6 ED DC) DC ELECTRICAL DISTRIBUTION SYSTEM X

(063) (SF6 ED DC) DC ELECTRICAL DISTRIBUTION SYSTEM (G2.1.20) CONDUCT OF OPERATIONS: Ability to interpret and execute procedure steps (CFR: 41.10 / 43.5 /

45.12) 4.6 47 58 (063) (SF6 ED DC) DC ELECTRICAL DISTRIBUTION SYSTEM X

(063K2.02) Knowledge of electrical power supplies to the following (CFR: 41.7): (SF6 ED DC) DC ELECTRICAL DISTRIBUTION SYSTEM Battery room ventilation 2.5 48 59 (064) (SF6 EDG)

EMERGENCY DIESEL GENERATOR SYSTEM X

(064A4.05) Ability to manually operate and/or monitor the (SF6 EDG) EMERGENCY DIESEL GENERATOR SYSTEM in the control room (CFR: 41.7 / 45.5 to 45.8): Transfer of EDG control between manual and automatic 3.6 49

60 (073) (SF7 PRM)

PROCESS RADIATION MONITORING SYSTEM X

(073K1.04) Knowledge of the physical connections and/or cause and effect relationships between the (SF7 PRM)

PROCESS RADIATION MONITORING SYSTEM and the following systems (CFR:

41.7 to 41.9 / 41.11 / 45.8 /

45.9): S/GB 3.4 50 61 (073) (SF7 PRM)

PROCESS RADIATION MONITORING SYSTEM X

(073K6.01) Knowledge of the effect of the following plant conditions, system malfunctions, or component malfunctions on the (SF7 PRM) PROCESS RADIATION MONITORING SYSTEM (CFR: 41.7 / 45.8 /

45.9): PRM component failures 3.2 51 62 (076) (SF4S SW)

SERVICE WATER SYSTEM X

(076) (SF4S SW) SERVICE WATER SYSTEM (191003K1.04) CONTROLLERS AND POSITIONERS (CFR:

41.7): Function and operation of pressure and temperature controllers, including pressure and temperature control valves 3.0 52 63 (078) (SF8 IAS)

INSTRUMENT AIR SYSTEM X

(078K5.03) Knowledge of the operational implications or cause and effect relationships of the following concepts as they apply to the (SF8 IAS)

INSTRUMENT AIR SYSTEM (CFR: 41.5 / 45.7): Loss of instrument air 3.9 53 64 (103) (SF5 CNT)

CONTAINMENT SYSTEM X

(103K6.13) Knowledge of the effect of the following plant conditions, system malfunctions, or component malfunctions on the (SF5 CNT) CONTAINMENT SYSTEM (CFR: 41.7 / 45.7):

MFW 3.2 54 65 (006) (SF2; SF3 ECCS)

EMERGENCY CORE COOLING SYSTEM X

(006A2.15) Ability to (a) predict the impacts of the following on the (SF2; SF3 ECCS) EMERGENCY CORE COOLING SYSTEM and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal operations (CFR:

41.5 / 43.5 / 45.3 / 45.4):

Vortex/cavitation 3.5 86 66 (026) (SF5 CSS)

CONTAINMENT SPRAY SYSTEM X

(026) (SF5 CSS)

CONTAINMENT SPRAY SYSTEM (G2.1.34) CONDUCT OF OPERATIONS: Knowledge of RCS or balance-of-plant chemistry controls, including parameters measured and reasons for the control (CFR:

41.10 / 43.5 / 45.12) 3.5 87

67 (061) (SF4S AFW)

AUXILIARY /

EMERGENCY FEEDWATER SYSTEM X

(061A2.01) Ability to (a) predict the impacts of the following on the (SF4S AFW)

AUXILIARY/EMERGENCY FEEDWATER SYSTEM and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal operations (CFR:

41.5 / 43.5 / 45.6): Inadvertent actuation of AFW at power 3.3 88 68 (064) (SF6 EDG)

EMERGENCY DIESEL GENERATOR SYSTEM X

(064) (SF6 EDG) EMERGENCY DIESEL GENERATOR SYSTEM (G2.4.14)

EMERGENCY PROCEDURES/PLAN:

Knowledge of general guidelines for emergency and abnormal operating procedures usage (CFR: 41.10

/ 43.1 / 45.13) 4.5 89 69 (103) (SF5 CNT)

CONTAINMENT SYSTEM X

(103) (SF5 CNT)

CONTAINMENT SYSTEM (G2.2.17) EQUIPMENT CONTROL: Knowledge of the process for managing maintenance activities during power operations, such as risk assessments, work prioritization, and coordination with the transmission system operator (CFR: 41.10 / 43.5 / 45.13) 3.8 90 K/A Category Totals:

2 3

2 3

2 3

3 3/2 2

2 3/3 Group Point Total:

28/5

ES-4.1-PWR PWR Examination Outline (Byron)

Plant SystemsTier 2/Group 2 (RO/SRO)

Item System / Name K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G

K/A Topic(s)

IR Q#

70 (014) (SF1 RPI) ROD POSITION INDICATION SYSTEM X

(014A2.09) Ability to (a) predict the impacts of the following on the (SF1 RPI)

ROD POSITION INDICATION SYSTEM and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal operations (CFR: 41.5 to 41.7 / 43.5 / 43.6 / 45.3 /

45.12 / 45.13): Urgent alarm 3.3 55 71 (015) (SF7 NI)

NUCLEAR INSTRUMENTATION SYSTEM X

(015A1.03) Ability to predict and/or monitor changes in parameters associated with operation of the (SF7 NI)

NUCLEAR INSTRUMENTATION SYSTEM, including (CFR:

41.5 / 45.5): NIS power indication 4.0 56 72 (033) (SF8 SFPCS)

SPENT FUEL POOL COOLING SYSTEM X

(033A4.03) Ability to manually operate and/or monitor the (SF8 SFPCS)

SPENT FUEL POOL COOLING SYSTEM in the control room (CFR: 41.7 /

45.5 to 45.8): Support systems for fill and transfer of SFPCS water 3.0 57 73 (041) (SF4S SDS)

STEAM DUMP/TURBINE BYPASS CONTROL SYSTEM X

(041K5.01) Knowledge of the operational implications or cause and effect relationships of the following concepts as they apply to the (SF4S SDS) STEAM DUMP/TURBINE BYPASS CONTROL SYSTEM (CFR:

41.5 / 45.7): Relationship of no-load T-avg. to atmospheric dump valve setpoint on a reactor trip 3.5 58 74 (045) (SF4S MTG)

MAIN TURBINE GENERATOR SYSTEM X

(045K4.41) Knowledge of (SF4S MTG) MAIN TURBINE GENERATOR SYSTEM design features and/or interlocks that provide for the following (CFR: 41.7): Lockout of command relay to generator breaker 2.7 59 75 (056) (SF4S CDS)

CONDENSATE SYSTEM X

(056K3.04) Knowledge of the effect that a loss or malfunction of the (SF4S CDS) CONDENSATE SYSTEM will have on the following systems or system parameters (CFR: 41.7 /

45.6): Heater drain system 3.1 60 76 (068) (SF9 LRS)

LIQUID RADWASTE SYSTEM X

(068A3.02) Ability to monitor automatic features of the (SF9 LRS) LIQUID RADWASTE SYSTEM, including (CFR: 41.7 / 45.8 /

45.9): Automatic isolation 3.6 61

77 (072) (SF7 ARM)

AREA RADIATION MONITORING SYSTEM X

(072K1.05) Knowledge of the physical connections and/or cause and effect relationships between the (SF7 ARM) AREA RADIATION MONITORING SYSTEM and the following systems (CFR: 41.7 to 41.9

/ 45.8 / 45.9 / 45.11): MRSS 3.3 62 78 (050) (SF 9 CRV*)

CONTROL ROOM VENTILATION X

(050) (SF 9 CRV*)

CONTROL ROOM VENTILATION (191005K1.05) MOTORS AND GENERATORS (CFR:

41.7): Explanation of the difference between starting current and operating (running) current in a motor 2.8 63 79 (002) (SF2; SF4P RCS) REACTOR COOLANT SYSTEM X

(002) (SF2; SF4P RCS)

REACTOR COOLANT SYSTEM (G2.2.25)

EQUIPMENT CONTROL:

Knowledge of the bases in TS for limiting conditions for operation and safety limits (SRO Only) (CFR:

43.2) 4.2 91 80 (029) (SF8 CPS)

CONTAINMENT PURGE SYSTEM X

(029) (SF8 CPS)

CONTAINMENT PURGE SYSTEM (G2.2.13)

EQUIPMENT CONTROL:

Knowledge of tagging and clearance procedures (CFR: 41.10 / 43.1 / 45.13) 4.3 92 81 075 (SF8 CW)

CIRCULATING WATER SYSTEM X

(075A2.12) Ability to (a) predict the impacts of the following on the (SF8 CW)

CIRCULATING WATER SYSTEM and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal operations (CFR: 41.5 / 43.5 / 45.3 /

45.13): Main condenser tube leak 3.3 93 K/A Category Totals:

1 0

1 1

1 0

1 1/1 1

1 1/2 Group Point Total:

9/3

Form 4.1-COMMON Common Examination Outline ES-4.1-COMMON COMMON Examination Outline (Byron)

Facility:

Byron Date of Exam:

12/12/2022 Generic Knowledge and Abilities Outline (Tier 3) (RO/SRO)

Category K/A #

Topic RO SRO-Only Item #

IR Q#

IR Q#

1.

Conduct of Operations G2.1.29 (G2.1.29) CONDUCT OF OPERATIONS: Knowledge of how to conduct system lineups, such as valves, breakers, or switches (CFR: 41.10 / 45.1 / 45.12) 82 4.1 64 G2.1.43 (G2.1.43) CONDUCT OF OPERATIONS: Ability to use an online power distribution monitoring system and/or procedures to determine the effects on reactivity of plant changes, such as RCS temperature, secondary plant, or fuel depletion (CFR: 41.10 /

43.6 / 45.6) 83 4.1 65 G2.1.37 (G2.1.37) CONDUCT OF OPERATIONS: Knowledge of procedures, guidelines, or limitations associated with reactivity management (CFR: 41.1 / 41.5 / 41.10 / 43.6 / 45.6) 84 4.6 94 G2.1.42 (G2.1.42) CONDUCT OF OPERATIONS: Knowledge of new and spent fuel movement procedures (SRO Only) (CFR: 43.7

/ 45.13) 85 3.4 95 Subtotal N/A 2

N/A 2

2.

Equipment Control G2.2.1 (G2.2.1) EQUIPMENT CONTROL: Ability to perform pre-startup procedures for the facility, including operating those controls associated with plant equipment that could affect reactivity (CFR:

41.5 / 41.10 / 43.5 / 43.6 / 45.1) 86 4.5 66 G2.2.35 (G2.2.35) EQUIPMENT CONTROL: Ability to determine TS for mode of operation (CFR: 41.7 / 41.10 / 43.2 / 45.13) 87 3.6 67 G2.2.6 (G2.2.6) EQUIPMENT CONTROL: Knowledge of the process for making changes to procedures (CFR: 41.10 / 43.3 / 45.13) 88 3.6 96 G2.2.42 (G2.2.42) EQUIPMENT CONTROL: Ability to recognize system parameters that are entry-level conditions for TS (CFR: 41.7 / 41.10 / 43.2 / 43.3 / 45.3) 89 4.6 97 Subtotal N/A 2

N/A 2

3.

Radiation Control G2.3.5 (G2.3.5) RADIATION CONTROL: Ability to use RMSs, such as fixed radiation monitors and alarms or personnel monitoring equipment (CFR: 41.11 / 41.12 / 43.4 / 45.9) 90 2.9 68 G2.3.11 (G2.3.11) RADIATION CONTROL: Ability to control radiation releases (CFR: 41.11 / 43.4 / 45.10) 91 4.3 98 Subtotal N/A 1

N/A 1

4.

Emergency Procedures /

Plan G2.4.12 (G2.4.12) EMERGENCY PROCEDURES/PLAN: Knowledge of operating crew responsibilities during emergency and abnormal operations (CFR: 41.10 / 45.12) 92 4.0 69 G2.4.18 (G2.4.18) EMERGENCY PROCEDURES/PLAN: Knowledge of the specific bases for emergency and abnormal operating procedures (CFR: 41.10 / 43.1 / 45.13) 93 4.0 99 G2.4.30 (G2.4.30) EMERGENCY PROCEDURES/PLAN: Knowledge of events related to system operation/status that must be reported to internal organizations or external agencies, such as the State, the NRC, or the transmission system operator (CFR: 41.10 / 43.5 / 45.11) 94 4.1 100 Subtotal N/A 1

N/A 2

Tier 3 Point Total N/A 6

N/A 7

Form 4.1-COMMON Common Examination Outline ES-4.1-COMMON COMMON Examination Outline (Byron)

Facility:

Byron Date of Exam:

12/12/2022 Theory (Tier 4) (RO)

Category K/A #

Topic RO Item #

IR Q#

Reactor Theory 192006 (192006K1.05) FISSION PRODUCT POISONS (CFR: 41.1):

Describe the following processes and state their effect on reactor operations: -- equilibrium xenon 95 3.1 70 192007 (192007K1.04) FUEL DEPLETION AND BURNABLE POISONS (CFR: 41.1): Describe how and why boron concentration changes over core life 96 3.4 71 192008 (192008K1.05) REACTOR OPERATIONAL PHYSICS (CFR:

41.1): (STARTUP AND APPROACH TO CRITICALITY) Explain characteristics to be observed when the reactor is very close to criticality 97 3.9 72 Subtotal N/A 3

Thermodynamics 193003 (193003K1.16) STEAM (CFR: 41.14): Define the following term: --

subcooled and compressed liquids 98 2.7 73 193004 (193004K1.15) THERMODYNAMIC PROCESS (CFR: 41.14):

(THROTTLING AND THE THROTTLING PROCESS) Determine the exit conditions for a throttling process based on the use of steam and/or water 99 2.8 74 193009 (193009K1.03) CORE THERMAL LIMITS (CFR: 41.14): Explain local peaking factor 100 2.7 75 Subtotal N/A 3

Tier 4 Point Total N/A 6