Form 3.2-1 Administrative Topics Outline Facility: Byron Nuclear Station Date of Examination: 12/12/22 Examination Level:

RO SRO Operating Test Number: 2022-301 Administrative Topic (Step 1)

Activity and Associated K/A (Step 2)

Type Code (Step 3)

RA-1 Conduct of Operations Perform AFD Weekly Surveillance KA: 2.1.25-Ability to interpret reference materials, such as graphs, curves, and tables (reference potential)

Candidate will complete 1BOSR 2.3.1-1, AXIAL FLUX DIFFERENCE WEEKLY SURVEILLANCE and determine if Axial Flux Difference (AFD) within limits.

R, N New for NRC 2022 RA-2 Conduct of Operations Manually Estimate Steam Generator Primary to Secondary Leak Rate KA: 2.1.19-Ability to use available indications to evaluate system or component status Candidate will perform 1BOSR SG-1 R, M Cert 2018 RA-3 Equipment Control Read a Print KA: - 2.2.41 Ability to obtain and interpret station electrical and mechanical drawings (reference potential) (3.5)

Candidate will obtain and use mechanical drawing to determine leak isolation points.

R, D Cert 2016 Radiation Control RA-4 Emergency Plan Perform a NARS Transmittal KA: 2.4.43 Knowledge of emergency communications systems and techniques Candidate will perform a NARS call S,D Cert 2019

Form 3.2-1 Administrative Topics Outline Facility: Byron Nuclear Station Date of Examination: 12/12/22 Examination Level:

RO SRO Operating Test Number: 2022-301 Administrative Topic (Step 1)

Activity and Associated K/A (Step 2)

Type Code (Step 3)

SA-1 Conduct of Operations Determine Shift Staffing KA: 2.1.5 Ability to use procedures related to shift staffing, such as minimum crew complement or overtime limitations (reference potential)

(3.9)

DETERMINE if the crew meets the Desired and Tech Spec required staffing levels R, D Cert 2017 SA-2 Conduct of Operations Review 1BOSR SG1 KA: 2.1.7 Ability to evaluate plant performance and make operational judgments based on operating characteristics, reactor behavior, and instrument interpretation.

(4.7)

Review 1BOSR SG-1, Steam Generator Primary to Secondary Leakage Estimation for completeness and accuracy of results.

R, D NRC 2008 SA-3 Equipment Control Determine Plant Barrier Impairment Requirements KA: 2.2.14 Knowledge of the process for controlling equipment configuration or status (4.3)

Determine required actions for door 0DSD701 being inoperable.

R, D Cert 2018 SA-4 Radiation Control Calculate Stay Times KA: 2.3.14 - Knowledge of radiation or contamination hazards that may arise during normal, abnormal, or emergency conditions or activities, such as analysis and interpretation of radiation and activity readings as they pertain to administrative, normal, abnormal, and emergency procedures or to analysis and interpretation of coolant activity, including comparison to emergency plan or regulatory limits (SRO Only)

(3.8)

Calculate the dose received and he maximum time allowed to perform the final task.

R, N New for NRC 2022 SA-5 Emergency Plan Evaluate EAL - SGTR KA: 2.4.41-Knowledge of the emergency action level thresholds and classifications (SRO Only)

(4.6)

Perform an Emergency Plan evaluation and classify the event. Fill out the NARS form for transmittal.

R, D NRC 2019