OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION January 26, 2023 Ms. Gayle Elliott, Director Licensing and Regulatory Affairs Framatome, Inc.

3315 Old Forest Road Lynchburg, VA 24501

SUBJECT:

FIRST SET OF REQUEST FOR ADDITIONAL INFORMATION REGARDING FRAMATOME TOPICAL REPORT, ANP-10350P, REVISION 0, FRAMATOME METHODOLOGY FOR BOILING WATER REACTORS: EVALUATION AND VALIDATION OF APOLLO2-A/ARTEMIS-B (EPID L-2022-TOP-0038)

Dear Ms. Elliott:

By letter dated June 30, 2022 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML22186A025), Framatome Inc. (Framatome) submitted Topical Report (TR) ANP-10350P, Revision 0, Framatome Methodology for Boiling Water Reactors:

Evaluation and Validation of APOLLO2-A/ ARTEMIS-B (ADAMS Package No. ML22186A071),

to the U.S. Nuclear Regulatory Commission (NRC) for review and approval. The NRC staff has reviewed the proposed TR and determined that additional information is needed to complete the review. Enclosed is the NRC staffs request for additional information questions.

If you have any questions, please contact me at 301-415-6695 or by e-mail to Ngola.Otto@nrc.gov.

Sincerely,

/RA/

Ngola Otto, Project Manager Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 99902041 Project No. 728

Enclosure:

RAI Questions (Proprietary)

NOTICE: Enclosure transmitted herewith contains proprietary information. When separated from Enclosure, this transmittal document is decontrolled.

ML23018A166 (Package)

ML23018A153 (Letter)

ML23018A154 (RAI Questions - Proprietary)

  • by e-mail OFFICE NRR/DORL/LLPB/PM*

NRR/DORL/LLPB/LA*

NRR/DSS/SNPB/BC*

NAME NOtto DHarrison SKrepel DATE 01/18/2023 01/25/2023 01/26/2023 OFFICE NRR/DORL/LLPB/Acting BC*

NRR/DORL/LLPB/PM*

NAME CRosales-Cooper NOtto DATE 01/26/2023 01/26/2023