NMP Unit 2 USAR Chapter 2 2B-814 Rev. 25, October 2022 TABLE 2B-40 COMPARISON OF ONSITE AND SYRACUSE NWS MAXIMUM PRECIPITATION TOTALS Time Period Nine Mile Point Syracuse NWS cm in cm in 1 hr 24 hr 1 mo 5.08 16.10 6.97 2.00 6.34 10.62 3.30 10.52 24.18 1.30 4.14 9.52 NOTE:

Period of record January 1974 through December 1976 and November 1978 through October 1980.

NMP Unit 2 USAR Chapter 2 2B-815 Rev. 25, October 2022 TABLE 2B-41 SYRACUSE NWS PRECIPITATION MEANS AND EXTREMES Month Mean(1)

(in)

Monthly(2)

Maximum (in)

Monthly(2)

Minimum (in) 24-Hour(2)

Maximum (in)

January February March April May June July August September October November December Annual 2.68 2.79 3.03 3.08 3.02 3.09 3.08 3.50 2.71 3.09 3.25 3.09 36.41 5.77 5.38 6.84 8.12 7.14 12.30 9.52 8.41 8.81 8.29 6.79 5.01 12.30 1.02 0.80 1.08 1.57 0.75 1.10 0.90 1.33 0.75 0.21 1.25 1.73 0.21 1.47 1.99 1.34 2.85 3.13 3.88 4.07 4.27 4.14 3.60 2.09 2.18 4.27 (1)

Period of record 1941-1970.

(2)

Period of record 1950-1980.

SOURCE:

Reference 3 of Section 2.3.6.

NMP Unit 2 USAR Chapter 2 2B-816 Rev. 25, October 2022 TABLE 2B-42 SYRACUSE NWS SNOWFALL MEANS AND EXTREMES Month Mean (in)

Monthly Maximum (in) 24-Hour Minimum (in)

January February March April May June July August September October November December Annual 27.8 26.9 17.3 3.2 0.1 0.0 0.0 0.0 0.0 0.6 9.4 26.2 111.5 72.2 72.6 37.2 12.0 1.2 0.0 0.0 0.0 0.0 4.4 25.9 52.5 72.6 24.5 21.4 14.7 7.1 1.2 0.0 0.0 0.0 0.0 2.4 12.1 15.6 24.5 NOTE:

Period of record 1950 through 1980.

SOURCE:

Reference 3 of Section 2.3.6.

NMP Unit 2 USAR Chapter 2 2B-817 Rev. 25, October 2022 TABLE 2B-42A MONTHLY RELATIVE HUMIDITY DATA RECOVERY Month Year Data Recovery Relative Humidity 61-m (200-ft)

(%)

9-m (30-ft)

(%)

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1974 100 100 100 100 100 100 100 100 100 90 100 100 100 100 100 100 100 100 100 100 100 100 99 100 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1975 91 100 100 100 100 100 97 100 100 100 100 100 91 100 100 100 100 100 100 92 0

0 0

0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1976 100 100 100 100 100 99 100 100 99 100 100 100 0

0 0

0 0

0 0

0 0

0 0

0

NMP Unit 2 USAR Chapter 2 2B-818 Rev. 25, October 2022 TABLE 2B-43 ONSITE RELATIVE HUMIDITY MEANS AND EXTREMES January 1974 Through December 1976 Combined Months Relative Humidity Mean

(%)

Hourly Maximum

(%)

Hourly Minimum

(%)

January February March April May June July August September October November December Annual 75 72 67 67 70 72 71 69 71 67 73 75 71 100 100 100 100 100 100 100 100 100 100 100 100 100 24 31 22 11 19 34 35 36 36 21 22 44 11 NOTE:

Relative humidity was measured at the 61-m (200-ft) level.

NMP Unit 2 USAR Chapter 2 2B-819 Rev.25, October 2022 TABLE 2B-44 ONSITE HOURLY RELATIVE HUMIDITY FREQUENCY DISTRIBUTIONS January 1974 Through December 1976 Relative Humidity

(%)

Month January February March April May June Sum Sum Sum Sum Sum Sum 100 124 5.7 105 5.2 192 8.6 156 7.2 185 8.3 117 5.4 95 - 99 101 4.7 81 4.0 85 3.8 72 3.3 79 3.5 78 3.6 90 - 94 122 5.6 157 7.7 111 5.0 137 6.4 167 7.5 178 8.3 85 - 89 153 7.1 149 7.3 133 6.0 98 4.5 152 6.8 144 6.7 80 - 84 279 12.9 206 10.1 133 6.0 157 7.3 206 9.2 198 9.2 75 - 79 363 16.8 199 9.8 184 8.2 167 7.7 180 8.1 204 9.5 70 - 74 336 15.5 249 12.2 179 8.0 181 8.4 207 9.3 259 12.0 65 - 69 198 9.2 237 11.6 171 7.7 206 9.6 162 7.3 267 12.4 60 - 64 163 7.5 171 8.4 190 8.5 205 9.5 218 9.8 246 11.4 55 - 59 125 5.8 107 5.3 151 6.8 177 8.2 161 7.2 215 10.0 50 - 54 92 4.3 133 6.5 148 6.6 184 8.5 156 7.0 127 5.9 45 - 49 48 2.2 106 5.2 190 8.5 129 6.0 96 4.3 70 3.3 40 - 44 47 2.2 76 3.7 177 7.9 94 4.4 107 4.8 30 1.4 35 - 39 6

0.3 44 2.2 110 4.9 67 3.1 75 3.4 20 0.9 30 - 34 2

0.1 20 1.0 51 2.3 78 3.6 49 2.2 1

0.1 25 - 29 4

0.2 0

0.0 22 1.0 36 1.7 17 0.8 0

0.0 20 - 24 1

0.1 0

0.0 5

0.2 8

0.4 10 0.5 0

0.0 15 - 19 0

0.0 0

0.0 0

0.0 2

0.1 2

0.1 0

0.0 10 - 14 0

0.0 0

0.0 0

0.0 3

0.1 0

0.0 0

0.0 5 - 9 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0 - 4 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 Total 2,164 100.0 2,040 100.0 2,232 100.0 2,157 100.0 2,229 100.0 2,154 100.0

NMP Unit 2 USAR Chapter 2 2B-820 Rev.25, October 2022 TABLE 2B-44 (Contd.)

Relative Humidity

(%)

Month July August September October November December Annual Sum Sum Sum Sum Sum Sum Sum 100 48 2.2 15 0.7 15 0.7 17 0.8 49 2.3 46 2.1 1,069 4.1 95 - 99 49 2.2 32 1.4 66 3.1 32 1.5 100 4.6 91 4.1 866 3.3 90 - 94 119 5.4 67 3.0 86 4.0 113 5.3 118 5.5 189 8.5 1,564 6.0 85 - 89 163 7.4 105 4.7 140 6.5 137 6.4 144 6.7 133 6.0 1,651 6.3 80 - 84 211 9.6 227 10.2 214 9.9 157 7.3 211 9.8 282 12.7 2,481 9.5 75 - 79 252 11.4 288 12.9 255 11.8 213 9.9 305 14.1 339 15.2 2,949 11.3 70 - 74 302 13.7 386 17.3 332 15.4 259 12.0 340 15.8 367 16.5 3,397 13.0 65 - 69 317 14.4 329 14.8 320 14.9 247 11.5 361 16.7 319 14.3 3,134 12.0 60 - 64 324 14.7 326 14.6 317 14.7 323 15.0 239 11.0 263 11.8 2,984 11.4 55 - 59 227 10.3 224 10.1 233 10.8 289 13.4 125 5.8 118 5.3 2,152 8.2 50 - 54 137 6.2 108 4.9 97 4.5 171 8.0 104 4.8 41 1.8 1,498 5.7 45 - 49 40 1.8 75 3.4 42 2.0 69 3.2 34 1.6 35 1.6 934 3.6 40 - 44 11 0.5 35 1.6 24 1.1 57 2.6 8

0.4 6

0.3 672 2.6 35 - 39 8

0.4 10 0.5 12 0.6 32 1.5 7

0.3 0

0.0 391 1.5 30 - 34 0

0.0 0

0.0 0

0.0 22 1.0 4

0.2 0

0.0 227 0.9 25 - 29 0

0.0 0

0.0 0

0.0 8

0.4 4

0.2 0

0.0 91 0.4 20 - 24 0

0.0 0

0.0 0

0.0 6

0.3 5

0.2 0

0.0 35 0.1 15 - 19 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 4

0.0 10 - 14 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.0 5 - 9 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0 - 4 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 Total 2,208 100.0 2,227 100.0 2,153 100.0 2,152 100.0 2,157 100.0 2,229 100.0 26,102 100.0 NOTE: Relative humidity was measured at the 61-m (200-ft) level.

NMP Unit 2 USAR Chapter 2 2B-821 Rev.25, October 2022 TABLE 2B-45 ONSITE DIURNAL RELATIVE HUMIDITY VARIATIONS January 1974 through December 1976 Relative Humidity (%)

Hour January February March April May June July August September October November December Annual 1

75.8 72.3 66.7 69.3 69.4 73.0 72.7 69.6 70.4 66.7 73.5 75.1 71.2 2

75.7 72.7 67.9 69.5 71.0 74.3 74.1 70.8 71.3 67.7 73.9 75.0 72.0 3

76.1 72.5 68.0 70.3 72.3 76.4 74.5 72.1 72.7 68.0 74.2 75.0 72.7 4

76.3 74.2 67.7 70.8 72.9 78.5 75.5 73.9 74.0 69.0 74.7 75.5 73.6 5

76.5 74.7 67.5 71.4 74.5 80.1 76.4 76.1 75.4 70.0 75.6 76.0 74.5 6

77.0 75.1 67.8 71.5 76.0 80.8 77.2 77.2 76.6 70.7 76.5 76.2 75.2 7

77.3 75.5 68.7 71.8 77.0 80.4 77.1 76.4 77.0 71.4 76.3 76.4 75.4 8

77.4 75.5 69.7 72.1 76.5 79.8 76.1 75.9 76.5 71.6 76.8 77.2 75.4 9

76.9 74.4 69.1 70.7 74.9 77.9 74.5 73.7 74.9 70.7 75.9 76.5 74.2 10 75.8 73.9 68.4 69.5 73.1 75.5 71.8 71.5 73.0 70.0 74.8 76.2 72.8 11 74.3 72.3 68.3 68.4 72.1 73.2 70.2 69.2 71.1 67.8 72.9 74.8 71.2 12 73.7 69.3 67.0 67.1 70.7 71.5 69.5 67.9 69.3 66.3 71.3 73.9 69.8 13 72.6 68.0 65.5 65.5 68.9 69.4 68.7 66.8 67.8 65.3 69.8 73.4 68.5 14 71.8 67.9 65.1 64.1 67.7 67.7 67.2 66.0 67.1 64.8 69.8 72.9 67.7 15 72.0 68.1 64.8 62.7 65.9 66.9 66.4 64.6 66.1 64.0 69.7 72.8 67.0 16 72.2 67.9 64.4 62.0 65.2 66.7 66.1 63.9 65.8 64.6 70.2 72.7 66.8 17 71.9 68.5 65.0 61.3 64.7 64.9 65.8 63.5 65.1 64.9 70.9 73.2 66.6 18 73.0 69.5 65.5 61.6 64.9 65.3 66.4 63.6 66.2 65.7 70.5 73.2 67.1 19 73.8 69.3 65.4 63.3 65.1 65.6 67.2 64.4 67.1 66.1 70.7 73.2 67.6 20 73.3 69.5 66.4 64.6 66.2 66.8 68.2 65.9 68.0 65.9 71.1 73.6 68.3 21 73.9 70.6 66.5 65.1 67.3 68.8 68.8 66.8 68.7 66.3 71.5 73.5 69.0 22 74.8 71.0 66.5 65.5 67.8 70.3 70.6 67.2 69.5 65.9 72.1 74.2 69.6 23 75.2 71.4 67.0 65.9 68.6 71.8 70.8 67.5 69.6 66.2 72.8 74.8 70.1 24 75.5 72.8 67.0 67.4 69.1 72.6 72.2 68.4 69.6 65.9 73.8 75.3 70.8 NOTE:

Relative humidity was measured at the 61-m (200-ft) level.

NMP Unit 2 USAR Chapter 2 2B-822 Rev. 25, October 2022 TABLE 2B-46 SYRACUSE NWS DIURNAL RELATIVE HUMIDITY VARIATIONS Month Hour (local time) 01

(%)

07

(%)

13

(%)

19

(%)

January February March April May June July August September October November December Annual 76 75 76 74 78 82 84 86 85 81 79 78 80 76 77 77 75 75 79 81 86 87 84 81 79 80 68 65 61 51 55 57 56 59 62 61 68 71 61 74 72 68 58 60 63 63 69 75 74 76 77 69 NOTE: Period of record 1964 through 1980.

SOURCE: Reference 3 of Section 2.3.6

NMP Unit 2 USAR Chapter 2 2B-823 Rev. 25, October 2022 TABLE 2B-47 ONSITE ABSOLUTE HUMIDITY MEANS AND EXTREMES January 1974 Through December 1976 Combined Months Mean (g/m3)

Hourly Maximum (g/m3)

Hourly Minimum (g/m3)

January February March April May June July August September October November December Annual 2.9 3.0 3.5 4.9 7.3 10.9 12.2 11.8 9.2 6.4 5.2 3.2 6.7 9.5 8.2 14.6 13.3 16.7 18.6 20.1 20.3 16.7 13.4 13.5 9.2 20.3 0.5 0.6 0.7 1.0 1.2 4.8 6.7 6.1 2.8 1.5 1.3 0.6 0.5 NOTE:

Absolute humidity is calculated from the 61-m (200-ft) relative humidity and the temperature at 61 m (200 ft),

(the 8-m (27-ft) temperature plus the 61-8 m (200-27 ft) temperature difference).

NMP Unit 2 USAR Chapter 2 2B-824 Rev. 25, October 2022 TABLE 2B-48 ONSITE HOURLY ABSOLUTE HUMIDITY FREQUENCY DISTRIBUTIONS January 1974 through December 1976 Absolute Humidity (g/m3)

Month January February March April May June Sum Sum Sum Sum Sum Sum 0 - 1.0 131 6.1 63 3.2 65 3.0 0

0.0 0

0.0 0

0.0 1.1 - 2.0 549 25.7 536 27.4 437 19.9 32 1.5 11 0.5 0

0.0 2.1 - 3.0 603 28.2 487 24.9 514 23.4 326 15.5 28 1.3 0

0.0 3.1 - 4.0 423 19.8 421 21.6 427 19.5 518 24.7 89 4.0 0

0.0 4.1 - 5.0 246 11.5 249 12.7 365 16.6 474 22.6 279 12.6 2

0.1 5.1 - 6.0 108 5.1 131 6.7 194 8.8 335 16.0 417 18.8 51 2.4 6.1 - 7.0 49 2.3 46 2.4 81 3.7 108 5.2 333 15.0 118 5.5 7.1 - 8.0 19 0.9 18 0.9 67 3.1 61 2.9 333 15.0 177 8.2 8.1 - 9.0 8

0.4 3

0.2 35 1.6 69 3.3 174 7.9 215 10.0 9.1 - 10.0 2

0.1 0

0.0 9

0.4 83 4.0 135 6.1 264 12.3 10.1 - 11.0 0

0.0 0

0.0 0

0.0 44 2.1 168 7.6 301 14.0 11.1 - 12.0 0

0.0 0

0.0 0

0.0 31 1.5 114 5.2 304 14.2 12.1 - 13.0 0

0.0 0

0.0 0

0.0 14 0.7 59 2.7 253 11.8 13.1 - 14.0 0

0.0 0

0.0 0

0.0 4

0.2 47 2.1 166 7.7 14.1 - 15.0 0

0.0 0

0.0 1

0.1 0

0.0 19 0.9 159 7.4 15.1 - 16.0 0

0.0 0

0.0 0

0.0 0

0.0 8

0.4 83 3.9 16.1 - 17.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.1 39 1.8 17.1 - 18.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 14 0.6 18.1 - 19.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 19.1 - 20.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 20.1 - 21.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 21.1 - 22.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0

NMP Unit 2 USAR Chapter 2 2B-825 Rev. 25, October 2022 TABLE 2B-48 (Contd.)

Absolute Humidity (g/m3)

Month July August September October November December Annual Sum Sum Sum Sum Sum Sum Sum 0 - 1.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 53 2.4 312 1.2 1.1 - 2.0 0

0.0 0

0.0 0

0.0 15 0.7 32 1.5 441 20.0 2,053 8.0 2.1 - 3.0 0

0.0 0

0.0 3

0.1 120 5.6 240 11.4 632 28.7 2,953 11.5 3.1 - 4.0 0

0.0 0

0.0 14 0.7 220 10.3 433 20.6 522 23.7 3,067 11.9 4.1 - 5.0 0

0.0 0

0.0 52 2.4 310 14.5 461 21.9 349 15.8 2,787 10.8 5.1 - 6.0 0

0.0 0

0.0 114 5.3 345 16.1 368 17.5 123 5.6 2,186 8.5 6.1 - 7.0 3

0.1 27 1.2 297 13.8 344 16.1 197 9.4 31 1.4 1,634 6.3 7.1 - 8.0 36 1.6 78 3.5 338 15.7 252 11.8 108 5.1 31 1.4 1,518 5.9 8.1 - 9.0 132 6.0 227 10.2 325 15.1 252 11.8 103 4.9 16 0.7 1,559 6.1 9.1 - 10.0 237 10.7 299 13.5 248 11.5 132 6.2 67 3.2 6

0.3 1,482 5.8 10.1 - 11.0 333 15.1 305 13.7 206 9.6 96 4.5 74 3.5 0

0.0 1,527 5.9 11.1 - 12.0 386 17.5 305 13.7 183 8.5 39 1.8 12 0.6 0

0.0 1,374 5.3 12.1 - 13.0 327 14.8 267 12.0 159 7.4 15 0.7 3

0.1 0

0.0 1,097 4.3 13.1 - 14.0 280 12.7 235 10.6 102 4.7 3

0.1 3

0.1 0

0.0 840 3.3 14.1 - 15.0 207 9.4 201 9.1 75 3.5 0

0.0 0

0.0 0

0.0 662 2.6 15.1 - 16.0 124 5.6 119 5.4 28 1.3 0

0.0 0

0.0 0

0.0 362 1.4 16.1 - 17.0 81 3.7 95 4.3 8

0.4 0

0.0 0

0.0 0

0.0 224 0.9 17.1 - 18.0 52 2.4 50 2.3 0

0.0 0

0.0 0

0.0 0

0.0 116 0.5 18.1 - 19.0 9

0.4 9

0.4 0

0.0 0

0.0 0

0.0 0

0.0 20 0.1 19.1 - 20.0 0

0.0 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 3

0.0 20.1 - 21.0 1

0.1 1

0.1 0

0.0 0

0.0 0

0.0 0

0.0 2

0.0 21.1 - 22.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 NOTE:

Absolute humidity is calculated from the 61-m (200-ft) relative humidity and the temperature at 61-m (the 8-m (27-ft) temperature plus the 61-8 m (200-27 ft) temperature difference).

NMP Unit 2 USAR Chapter 2 2B-826 Rev. 25, October 2022 TABLE 2B-49 ONSITE DIURNAL ABSOLUTE HUMIDITY VARIATIONS January 1974 through December 1976 Absolute Humidity (g/m3)

Hour January February March April May June July August September October November December Annual 1

2.8 2.9 3.4 5.0 7.1 10.7 12.0 11.7 9.0 6.1 5.1 3.1 6.6 2

2.8 2.9 3.5 4.9 7.2 10.6 12.0 11.7 9.0 6.2 5.1 3.1 6.6 3

2.8 2.9 3.4 4.9 7.2 10.7 12.0 11.6 8.9 6.1 5.1 3.1 6.6 4

2.8 2.8 3.3 4.8 7.1 10.7 11.9 11.7 8.9 6.1 5.1 3.1 6.6 5

2.7 2.8 3.3 4.8 7.1 10.7 11.9 11.8 8.9 6.1 5.1 3.1 6.6 6

2.8 2.8 3.3 4.8 7.2 10.7 11.9 11.7 8.9 6.1 5.1 3.1 6.6 7

2.8 2.8 3.3 4.8 7.3 10.7 11.8 11.7 8.9 6.2 5.1 3.1 6.6 8

2.8 2.9 3.3 4.8 7.3 10.8 11.9 11.7 9.0 6.2 5.1 3.1 6.6 9

2.8 2.8 3.3 4.9 7.5 10.9 12.1 11.8 9.1 6.3 5.1 3.1 6.7 10 2.8 2.9 3.4 4.9 7.5 11.1 12.2 11.9 9.2 6.5 5.1 3.1 6.8 11 2.8 2.9 3.4 4.9 7.5 11.0 12.1 11.8 9.3 6.5 5.1 3.1 6.8 12 2.8 2.9 3.4 4.8 7.4 10.9 12.2 11.8 9.3 6.5 5.2 3.2 6.8 13 2.9 2.9 3.4 4.9 7.4 11.0 12.2 11.8 9.4 6.6 5.2 3.2 6.8 14 2.9 3.0 3.5 4.8 7.3 10.8 12.1 11.8 9.4 6.6 5.3 3.2 6.8 15 2.9 3.0 3.5 4.7 7.3 10.8 12.1 11.7 9.4 6.6 5.2 3.2 6.8 16 2.9 3.1 3.5 4.8 7.2 10.9 12.1 11.7 9.4 6.6 5.2 3.2 6.8 17 2.9 3.0 3.5 4.8 7.2 10.8 12.2 11.8 9.4 6.7 5.2 3.2 6.8 18 2.9 3.1 3.6 4.7 7.3 11.0 12.4 11.9 9.4 6.6 5.2 3.2 6.8 19 2.9 3.1 3.5 4.8 7.4 10.8 12.4 11.9 9.4 6.5 5.2 3.1 6.8 20 2.8 3.1 3.6 4.8 7.4 10.8 12.2 11.9 9.4 6.5 5.1 3.1 6.8 21 2.8 3.1 3.5 4.9 7.4 10.9 12.2 12.0 9.4 6.4 5.1 3.1 6.8 22 2.8 3.1 3.5 4.9 7.4 11.0 12.4 12.0 9.3 6.3 5.1 3.1 6.8 23 2.8 3.1 3.5 4.9 7.4 11.0 12.2 11.8 9.2 6.2 5.1 3.1 6.7 24 2.8 3.0 3.5 4.9 7.3 10.8 12.2 11.7 9.1 6.1 5.1 3.1 6.7 NOTE:

Absolute humidity is calculated from the 61-m (200-ft) relative humidity and the temperature at 61 m, the 8-m (27-ft) temperature plus the 61-8 m (200-27 ft) temperature difference.

NMP Unit 2 USAR Chapter 2 2B-827 Rev. 25, October 2022 TABLE 2B-50 ONSITE DEW POINT TEMPERATURE MEANS AND EXTREMES January 1974 through December 1976 Combined Months Mean (F)

Hourly Maximum (F)

Hourly Minimum (F)

January February March April May June July August September October November December Annual 17 18 21 31 42 54 57 56 49 38 32 20 37 50.6 46.0 62.9 60.9 67.4 71.0 72.8 73.3 67.0 60.7 60.8 49.5 73.3

-16.0

-12.3

-10.0

-2.6 0.8 32.8 41.8 38.3 19.4 4.7 2.4

-13.5

-16.0 NOTE:

Dew point temperature is calculated from the 61-m (200-ft) relative humidity and the temperature at 61 m (the 8-m (27-ft) temperature plus the 61-8 m (200-27-ft) temperature difference).

NMP Unit 2 USAR Chapter 2 2B-828 Rev. 25, October 2022 TABLE 2B-51 ONSITE HOURLY DEW POINT TEMPERATURE FREQUENCY DISTRIBUTIONS January 1974 through December 1976 Dew Point Temperature

(°F)

Month January February March April May June Sum Sum Sum Sum Sum Sum

>80 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 75

- 79 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 70

- 74 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 7

0.3 65

- 69 0

0.0 0

0.0 0

0.0 0

0.0 5

0.2 130 6.1 60

- 64 0

0.0 0

0.0 1

0.1 8

0.4 89 4.0 393 18.3 55

- 59 0

0.0 0

0.0 0

0.0 49 2.3 202 9.1 583 27.1 50

- 54 2

0.1 0

0.0 14 0.6 122 5.8 256 11.6 483 22.5 45

- 49 19 0.9 6

0.3 59 2.7 86 4.1 314 14.2 326 15.2 40

- 44 36 1.7 37 1.9 92 4.2 107 5.1 443 20.0 156 7.3 35

- 39 97 4.5 107 5.5 170 7.7 264 12.6 440 19.9 68 3.2 30

- 34 177 8.3 228 11.7 323 14.7 491 23.4 283 12.8 2

0.1 25

- 29 284 13.3 290 14.8 287 13.1 382 18.2 131 5.9 0

0.0 20

- 24 349 16.3 288 14.7 332 15.1 313 14.9 18 0.8 0

0.0 15

- 19 380 17.8 289 14.8 302 13.8 183 8.7 20 0.9 0

0.0 10

- 14 237 11.1 285 14.6 231 10.5 72 3.4 8

0.4 0

0.0 5

- 9 228 10.7 205 10.5 176 8.0 19 0.9 3

0.1 0

0.0 0

- 4 168 7.9 126 6.5 112 5.1 2

0.1 3

0.1 0

0.0

-5

- -1 90 4.2 80 4.1 72 3.3 1

0.1 0

0.0 0

0.0

-10

- -6 52 2.4 11 0.6 24 1.1 0

0.0 0

0.0 0

0.0

-15

- -11 18 0.8 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0

-20

- -16 1

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 Total 2,138 100.0 1,954 100.0 2,195 100.0 2,099 100.0 2,215 100.0 2,148 100.0

NMP Unit 2 USAR Chapter 2 2B-829 Rev. 25, October 2022 TABLE 2B-51 (Contd.)

Dew Point Temperature

(°F)

Month July August September October November December Annual Sum Sum Sum Sum Sum Sum Sum

>80 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 75 -

79 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 70 -

74 26 1.2 23 1.0 0

0.0 0

0.0 0

0.0 0

0.0 56 0.2 65 -

69 243 11.0 247 11.1 32 1.5 0

0.0 0

0.0 0

0.0 657 2.6 60 -

64 616 27.9 533 24.0 240 11.2 4

0.2 3

0.1 0

0.0 1,887 7.3 55 -

59 702 31.8 600 27.0 346 16.1 89 4.2 30 1.4 0

0.0 2,601 10.1 50 -

54 470 21.3 531 23.9 417 19.4 198 9.2 126 6.0 1

0.1 2,620 10.2 45 -

49 139 6.3 236 10.6 493 22.9 377 17.6 147 7.0 37 1.7 2,239 8.7 40 -

44 12 0.5 49 2.2 400 18.6 390 18.2 213 10.1 39 1.8 1,974 7.7 35 -

39 0

0.0 2

0.1 141 6.6 364 17.0 329 15.7 90 4.1 2,072 8.0 30 -

34 0

0.0 0

0.0 60 2.8 319 14.8 432 20.6 282 12.8 2,596 10.1 25 -

29 0

0.0 0

0.0 13 0.6 167 7.8 348 16.6 350 15.9 2,252 8.7 20 -

24 0

0.0 0

0.0 10 0.5 129 6.0 266 12.7 309 18.1 2,103 8.2 15 -

19 0

0.0 0

0.0 0

0.0 73 3.4 137 6.5 379 17.2 1,763 6.8 10 -

14 0

0.0 0

0.0 0

0.0 30 1.4 48 2.3 280 12.7 1,191 4.6 5 -

9 0

0.0 0

0.0 0

0.0 4

0.2 19 0.9 145 6.6 799 3.1 0 -

4 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 130 5.9 544 2.1

-1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 61 2.8 304 1.2

-6 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 10 0.5 97 0.4

-11 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 22 0.1

-16 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 Total 2,208 100.0 2,221 100.0 2,152 100.0 2,143 100.0 2,101 100.0 2,204 100.0 25,778 100.0 NOTE:

Dew point temperature is calculated from the 61-m (200-ft) relative humidity and the temperature at 61 m, the 8-m (27-ft) temperature plus the 61-8 m (200-27 ft) temperature difference).

NMP Unit 2 USAR Chapter 2 2B-830 Rev. 25, October 2022 TABLE 2B-52 ONSITE DIURNAL DEW POINT TEMPERATURE VARIATIONS January 1974 through December 1976 Dew Point Temperature (°F)

Hour January February March April May June July August September October November December Annual 1

17.1 18.3 21.1 31.0 41.2 53.1 57.0 55.8 48.2 36.9 31.8 19.7 36.2 2

17.1 18.0 21.3 30.8 41.3 53.0 56.8 55.9 47.9 37.0 31.9 19.5 36.1 3

17.0 17.5 21.0 30.8 41.3 53.2 56.6 55.7 47.8 36.8 31.8 19.3 36.0 4

16.9 17.5 20.3 30.5 41.1 53.1 56.5 55.7 47.7 36.7 31.8 19.2 35.8 5

16.5 17.5 20.2 30.6 41.2 53.1 56.5 56.1 47.9 36.9 31.7 19.3 35.8 6

16.5 17.4 20.1 30.2 41.4 53.3 56.5 56.0 47.8 36.9 31.9 19.3 35.8 7

16.5 17.4 20.2 30.1 42.0 53,3 56.4 55.9 47.9 36.9 31.7 19.2 35.9 8

16.6 17.4 20.4 30.5 42.2 53.9 56.9 56.1 48.1 37.1 31.8 19.3 36.1 9

16.6 17.2 20.5 30.8 42.6 54.4 57.6 56.7 48.7 37.7 32.1 19.1 36.4 10 16.9 17.6 21.0 30.8 42.6 54.6 57.8 57.0 49.2 38.5 32.4 19.3 36.7 11 16.7 18.0 20.8 31.0 42.7 54.4 57.8 56.9 49.5 38.8 32.5 19.7 36.8 12 17.0 17.8 21.2 30.4 42.2 54.2 58.0 56.7 49.5 38.7 32.5 20.2 36.7 13 17.4 18.2 21.1 30.4 42.3 54.2 57.9 56.9 49.5 39.0 32.5 20.4 36.9 14 17.5 18.7 21.6 30.1 41.8 53.8 57.8 56.9 49.6 38.9 32.8 20.5 36.9 15 17.8 19.1 22.0 29.8 41.8 53.8 57.9 56.7 49.7 39.1 32.7 20.8 37.0 16 17.8 19.4 21.9 30.2 41.7 54.2 57.8 56.7 49.7 39.3 32.6 20.7 37.1 17 17.2 19.1 22.3 30.1 41.6 53.9 57.9 56.9 49.6 39.4 32.8 20.5 37.0 18 17.3 19.4 22.5 30.0 41.7 54.4 58.2 57.0 49.5 39.1 32.5 20.3 37.0 19 17.3 19.5 22.4 30.3 42.1 54.0 58.2 56.8 49.4 38.7 32.4 20.2 37.0 20 17.1 19.2 22.5 30.5 42.1 53.7 57.7 56.6 49.4 38.4 32.2 20.1 36.8 21 17.0 19.3 22.2 30.9 42.3 53.6 57.6 56.9 49.2 38.1 32.1 19.9 36.8 22 17.2 19.2 21.9 30.8 42.1 53.8 57.8 56.7 49.0 37.5 32.2 20.0 36.7 23 16.9 19.2 21.9 30.9 42.0 53.7 57.5 56.3 48.5 37.3 31.8 19.9 36.5 24 16.9 19.1 21.6 31.1 41.9 53.5 57.4 56.1 48.2 36.8 31.6 19.8 36.4 NOTE:

Dew point temperature is calculated from the 61-m (200-ft) relative humidity and the temperature at 61 m (200 ft), (the 8-m (27-ft) temperature plus the 61-8 m (200-27 ft) temperature difference).

NMP Unit 2 USAR Chapter 2 2B-831 Rev. 25, October 2022 TABLE 2B-52A MONTHLY DEW POINT TEMPERATURE DATA RECOVERY Month Year Data Recovery Dew Point Temperature(%)

Nov 1978 25 Dec 90 Jan 1979 5

Feb 68 Mar 60 Apr 53 May 93 Jun 75 Jul 96 Aug 26 Sep 0

Oct 45 Nov 77 Dec 100 Jan 1980 29 Feb 0

Mar 0

Apr 0

May 0

Jun 0

Jul 0

Aug 0

Sep 71 Oct 94 NOTE:

Dew point temperature is measured at the 8-m (25-ft) level of the meteorological tower.

NMP Unit 2 USAR Chapter 2 2B-832 Rev. 25, October 2022 TABLE 2B-53 MEAN NUMBER OF DAYS AT SYRACUSE NWS WITH FOG, HAZE AND/OR SMOKE Fog Visibility Month

<11 km (7 mi)

<0.40 km (0.25 mi)

Haze and/or Smoke January February March April May June July August September October November December Annual 7

5 9

8 10 10 9

11 12 10 12 10 113 1

1 1

1 1

1 1

1 1

1 9

6 5

7 4

6 10 13 14 11 7

4 5

91

  • Less than 0.5 day.

SOURCE: Reference 31 of Section 2.3.6.

NMP Unit 2 USAR Chapter 2 2B-833 Rev. 25, October 2022 TABLE 2B-54 NRC FORMAT FOR NINE MILE POINT METEOROLOGICAL DATA TAPE January 1974 Through December 1976 and November 1978 Through October 1980 Data Description Unit Format Column ID number (000041)

I6 1-6 Year I2 7-8 Julian day I3 9-11 Hour I4 12-15 Upper height (m x 10) (610)

I5 16-20 200-ft wind direction (deg Az x 10)

I5 21-25 200-ft wind speed (m/sec x 10)

I5 26-30 Blank 5X 31-35 Blank 5X 36-40 200-ft relative humidity

(% x 10)

I5 41-45 Blank 5X 46-50 Intermediate wind height (m x 10) (305)

I5 51-55 100-ft wind direction (deg Az x 10)

I5 56-60 100-ft wind speed (m/sec x 10)

I5 61-65 Blank 5X 66-70 Blank 5X 71-75 Blank 5X 76-80 Blank 5X 81-85 Lower wind height (m x 10) (91)

I5 86-90

NMP Unit 2 USAR Chapter 2 2B-834 Rev. 25, October 2022 TABLE 2B-54 (contd.)

Data Description Unit Format Column 30-ft vane direction (deg Az x 10)

I5 91-95 30-ft cup speed (m/sec x 10)

I5 96-100 Blank 5X 101-105 27-ft ambient temperature (°C x 10)

I5 106-110 30-ft relative humidity

(% x 10)

I5 111-115 Pressure (mb x 10)

I5 116-120 200-27-ft temperature difference

(°C/100 m x 10)

I5 121-125 Blank 5X 126-130 100-27-ft temperature difference

(°C/100 m x 10)

I5 131-135 Precipitation (mm x 10)

I5 136-140 25-ft dry bulb temperature

(°C x 10)

I5 141-145 250-ft dew point temperature

(°C x 10)

I5 146-150 30-ft aerovane direction (deg Az x 10)

I5 151-155 30-ft aerovane speed (m/sec x 10)

I5 156-160

NMP Unit 2 USAR Chapter 2 2B-836 Rev. 25, October 2022 TABLE 2B-55 JOINT FREQUENCY DISTRIBUTIONS OF WIND SPEED AND WIND DIRECTION BY ATMOSPHERIC STABILITY CLASS BASED ON 200-FT WINDS (1997-2001)

STABILITY CLASS: A Direction 0.44 1.0 2.0 3.0 4.0 5.0 6.0 8.0 10.0 13.0 18.0

>18.0 Total MAXIMUM METERS PER SECOND N

0 0

7 44 45 43 45 108 85 91 24 7

499 NNE 0

0 1

18 42 40 28 70 45 48 21 0

313 NE 0

0 2

3 14 5

3 5

2 2

0 0

36 ENE 0

0 0

1 0

0 0

1 0

0 0

0 2

E 0

0 0

1 2

0 0

1 0

0 0

0 4

ESE 0

0 0

1 6

8 5

5 1

1 0

0 27 SE 0

0 2

1 4

16 17 24 19 9

3 0

95 SSE 0

0 0

3 3

12 11 26 10 5

1 0

71 S

0 0

0 3

6 7

8 3

3 0

0 0

30 SSW 0

0 3

0 0

3 2

4 0

0 0

0 12 SW 0

0 2

1 0

1 1

0 0

0 0

0 5

WSW 0

0 0

1 10 46 91 172 71 19 36 3

449 W

0 1

4 7

9 18 25 35 21 46 44 16 226 WNW 0

0 7

33 34 29 19 36 29 69 141 34 431 NW 0

1 10 63 64 53 37 71 73 147 95 9

623 NNW 0

0 25 64 65 53 44 87 80 121 31 0

570 TOTAL 0

2 63 244 34 334 336 648 439 558 396 69 3393

NMP Unit 2 USAR Chapter 2 2B-837 Rev. 25, October 2022 TABLE 2B-55 (Contd.)

STABILITY CLASS: B Direction 0.44 1.0 2.0 3.0 4.0 5.0 6.0 8.0 10.0 13.0 18.0

>18.0 Total MAXIMUM METERS PER SECOND N

0 0

6 11 17 14 17 56 57 39 15 0

232 NNE 0

0 4

15 19 16 11 37 45 35 13 0

195 NE 0

0 0

11 7

10 1

6 0

0 0

0 35 ENE 0

0 1

1 3

0 0

1 0

0 0

0 6

E 0

0 1

1 0

1 1

0 0

0 0

0 4

ESE 0

1 1

2 6

6 7

3 3

0 0

0 29 SE 0

0 0

5 8

12 21 21 8

2 0

0 77 SSE 0

0 1

4 17 15 18 19 6

1 0

0 81 S

0 0

2 1

13 16 10 10 9

3 0

0 64 SSW 0

0 3

5 4

5 3

0 0

0 0

0 20 SW 0

0 1

1 0

2 0

4 1

0 0

0 9

WSW 0

0 0

4 9

27 36 58 38 33 39 5

249 W

0 0

3 5

23 30 25 44 58 62 83 16 349 WNW 0

0 1

21 24 26 11 36 36 84 83 5

327 NW 0

0 5

11 6

14 27 82 65 95 30 0

335 NNW 0

0 6

5 9

12 20 50 71 51 9

0 233 TOTAL 0

1 35 103 165 206 208 427 397 405 272 26 2245

NMP Unit 2 USAR Chapter 2 2B-838 Rev. 25, October 2022 TABLE 2B-55 (Contd.)

STABILITY CLASS: C Direction 0.44 1.0 2.0 3.0 4.0 5.0 6.0 8.0 10.0 13.0 18.0

>18.0 Total MAXIMUM METERS PER SECOND N

0 1

10 10 18 11 26 84 54 38 20 0

272 NNE 0

0 2

22 22 25 17 71 53 57 18 1

288 NE 0

0 1

20 15 7

4 12 6

6 0

0 71 ENE 0

0 2

2 7

0 0

0 0

0 0

0 11 E

0 0

3 3

0 0

1 1

0 0

0 0

8 ESE 0

0 2

4 19 6

7 7

1 0

0 0

46 SE 0

1 1

8 17 16 30 29 21 20 1

0 144 SSE 0

0 1

4 27 25 27 27 9

5 0

0 125 S

0 1

2 4

22 32 36 21 17 2

0 0

137 SSW 0

0 0

8 7

8 6

2 3

0 0

0 34 SW 0

0 3

2 3

0 3

3 0

5 1

0 20 WSW 0

0 3

5 16 25 33 69 26 59 62 9

307 W

0 0

3 20 42 47 63 86 80 130 98 12 581 WNW 0

3 4

17 26 32 21 58 73 84 95 5

418 NW 0

1 11 22 11 14 43 84 85 62 19 1

353 NNW 0

0 6

13 9

15 27 45 57 55 1

0 228 TOTAL 0

7 54 164 261 263 344 599 485 523 315 28 3043

NMP Unit 2 USAR Chapter 2 2B-839 Rev. 25, October 2022 TABLE 2B-55 (Contd.)

STABILITY CLASS: D Direction 0.44 1.0 2.0 3.0 4.0 5.0 6.0 8.0 10.0 13.0 18.0

>18.0 Total MAXIMUM METERS PER SECOND N

0 4

36 84 65 94 104 170 100 98 33 0

788 NNE 1

7 49 101 105 108 134 356 234 161 40 0

1296 NE 0

9 61 129 181 189 137 185 79 29 1

0 1000 ENE 0

8 44 73 67 37 18 12 1

0 0

0 260 E

1 4

45 51 66 51 45 29 3

1 0

0 296 ESE 1

4 33 83 97 100 153 179 79 14 2

0 745 SE 1

5 25 81 134 185 289 587 303 125 11 0

1746 SSE 1

2 35 63 129 143 175 332 191 67 10 0

1148 S

1 6

15 61 132 199 216 412 179 45 3

0 1269 SSW 1

4 24 62 108 172 198 276 40 10 0

0 895 SW 2

3 23 38 58 92 144 229 140 49 2

0 780 WSW 0

6 18 61 99 160 219 443 298 286 195 20 1805 W

1 7

33 117 178 181 178 394 376 387 289 24 2165 WNW 0

2 51 82 94 104 131 300 232 251 139 12 1398 NW 2

6 50 73 70 81 127 231 204 117 23 0

984 NNW 0

5 40 60 50 87 106 188 119 62 14 0

731 TOTAL 12 82 582 1219 1633 1983 2374 4323 2578 1702 762 56 17306

NMP Unit 2 USAR Chapter 2 2B-840 Rev. 25, October 2022 TABLE 2B-55 (Contd.)

STABILITY CLASS: E Direction 0.44 1.0 2.0 3.0 4.0 5.0 6.0 8.0 10.0 13.0 18.0

>18.0 Total MAXIMUM METERS PER SECOND N

0 8

27 35 27 21 16 36 24 18 2

0 214 NNE 0

7 23 42 31 33 23 29 18 23 6

0 235 NE 0

6 52 73 93 37 24 17 6

5 0

0 313 ENE 0

8 34 92 71 28 10 4

0 0

0 0

247 E

1 7

32 57 71 38 16 15 0

1 0

0 238 ESE 2

8 25 49 63 73 76 67 11 2

1 0

377 SE 1

5 16 33 74 116 246 630 235 44 5

0 1405 SSE 2

2 27 46 83 104 170 605 320 62 1

0 1422 S

0 5

16 41 52 106 213 614 245 24 0

0 1316 SSW 1

5 20 37 48 108 216 404 58 1

0 0

898 SW 1

6 31 51 60 97 139 213 62 7

2 0

669 WSW 0

8 45 58 102 212 183 349 236 175 56 5

1429 W

0 3

29 95 98 102 84 136 105 106 56 4

818 WNW 0

3 31 56 38 37 22 52 54 54 20 2

369 NW 0

11 13 41 29 12 12 30 21 7

5 0

181 NNW 2

5 20 39 15 18 20 19 11 12 1

0 162 TOTAL 10 97 441 845 955 1142 1470 3220 1406 541 155 11 10293

NMP Unit 2 USAR Chapter 2 2B-841 Rev. 25, October 2022 TABLE 2B-55 (Contd.)

STABILITY CLASS: F Direction 0.44 1.0 2.0 3.0 4.0 5.0 6.0 8.0 10.0 13.0 18.0

>18.0 Total MAXIMUM METERS PER SECOND N

1 4

13 17 8

9 9

13 8

10 0

0 92 NNE 0

2 15 19 13 10 11 7

7 4

0 0

88 NE 0

4 22 40 17 6

4 5

2 0

0 0

100 ENE 0

9 26 41 23 16 2

0 0

0 0

0 117 E

1 6

21 30 51 22 18 8

0 0

0 0

157 ESE 1

3 12 32 21 25 45 24 0

0 0

0 163 SE 0

0 16 21 26 36 39 109 8

0 0

0 255 SSE 0

4 13 18 27 39 52 187 25 0

0 0

365 S

2 2

14 17 18 33 30 158 25 0

0 0

299 SSW 1

3 14 17 23 31 42 138 17 0

0 0

286 SW 0

9 25 30 58 70 85 93 1

0 0

0 371 WSW 1

4 28 40 80 71 53 50 20 17 11 0

375 W

0 2

21 44 38 39 18 24 26 28 5

0 245 WNW 2

2 24 34 21 9

3 15 9

7 1

0 127 NW 0

1 25 10 12 8

2 3

8 5

0 0

74 NNW 0

5 12 15 9

11 7

6 9

2 0

0 76 TOTAL 9

60 301 425 445 435 420 840 165 73 17 0

3190

NMP Unit 2 USAR Chapter 2 2B-842 Rev. 25, October 2022 TABLE 2B-55 (Contd.)

STABILITY CLASS: G Direction 0.44 1.0 2.0 3.0 4.0 5.0 6.0 8.0 10.0 13.0 18.0

>18.0 Total MAXIMUM METERS PER SECOND N

1 7

21 14 8

5 1

10 14 8

2 0

91 NNE 1

7 25 15 10 2

4 10 5

9 0

0 88 NE 0

8 27 36 3

0 2

1 1

0 0

0 78 ENE 0

10 33 30 16 3

2 0

0 0

0 0

94 E

3 12 32 49 37 21 7

4 0

0 0

0 165 ESE 1

6 36 38 30 33 28 19 0

0 0

0 191 SE 0

8 23 25 29 35 29 36 3

0 0

0 188 SSE 4

8 25 27 41 34 54 95 2

0 0

0 290 S

1 14 31 31 26 40 45 90 2

0 0

0 280 SSW 1

5 28 42 46 52 47 45 0

0 0

0 266 SW 1

5 46 58 86 80 63 21 0

0 0

0 360 WSW 0

7 44 62 81 54 18 14 3

7 2

0 292 W

1 14 33 40 17 12 5

4 7

8 1

0 142 WNW 1

11 34 21 7

0 1

1 1

1 1

0 79 NW 0

7 13 12 3

1 1

3 4

3 1

0 48 NNW 1

4 26 12 5

3 2

7 8

6 0

0 74 TOTAL 16 133 477 512 445 375 309 360 50 42 7

0 2726

NMP Unit 2 USAR Chapter 2 2B-843 Rev. 25, October 2022 TABLE 2B-55 (Contd.)

STABILITY CLASS: ALL Direction 0.44 1.0 2.0 3.0 4.0 5.0 6.0 8.0 10.0 13.0 18.0

>18.0 Total MAXIMUM METERS PER SECOND N

2 24 120 215 188 197 218 477 342 302 96 7

2188 NNE 2

23 119 232 242 234 228 580 407 337 98 1

2503 NE 0

27 165 312 330 254 175 231 96 42 1

0 1633 ENE 0

35 140 240 187 84 32 18 1

0 0

0 737 E

6 29 134 192 227 133 88 58 3

2 0

0 872 ESE 5

22 109 209 242 251 321 304 95 17 3

0 1578 SE 2

19 83 174 292 416 671 1436 597 200 20 0

3910 SSE 7

16 102 165 327 372 507 1291 563 140 12 0

3502 S

4 28 80 158 269 433 558 1308 480 74 3

0 3395 SSW 4

17 92 171 236 379 514 869 118 11 0

0 2411 SW 4

23 131 181 265 342 435 563 204 61 5

0 2214 WSW 1

25 138 231 397 595 633 1155 692 596 401 42 4906 W

2 27 126 328 405 429 398 723 673 767 576 72 4526 WNW 3

21 152 264 244 237 208 498 434 550 480 58 3149 NW 2

27 127 232 195 183 249 504 460 436 173 10 2598 NNW 3

19 135 208 162 199 226 402 355 309 56 0

2074 TOTAL 47 382 1953 3512 4208 4738 5461 10417 5520 3844 1924 190 42196