U.S. NUCLEAR REGULATORY COMMISSION DOCKET 50-410 LICENSE NPF-69 NINE MILE POINT NUCLEAR STATION UNIT 2 UPDATED SAFETY ANALYSIS REPORT OCTOBER 2022 REVISION 25

NMP Unit 2 USAR CHAPTER 8 LIST OF EFFECTIVE FIGURES Chapter 08 EF 8-1 Rev. 25, October 2022 Revision Revision Figure No.

Number Figure No.

Number 8.1-1 R08 8.3-6 Sh 2 R00 8.2-1 R23 8.3-6 Sh 3 R00 8.2-1a R08 8.3-6 Sh 4 R00 8.2-1b R08 8.3-6 Sh 5 R08 8.2-1c R00 8.3-6 Sh 6 R05 8.2-2 A26 8.3-6 Sh 7 R00 8.2-3 A07 8.3-6 Sh 8 R03 8.2-4 A00 8.3-6 Sh 9 R00 8.2-5 A26 8.3-6 Sh 10 R03 8.2-5a A26 8.3-6 Sh 11 R00 8.2-6 A26 8.3-6 Sh 12 R00 8.2-6a A26 8.3-6 Sh 13 R16 8.2-6b A26 8.3-6 Sh 14 R00 8.2-6c A26 8.3-6 Sh 15 R03 8.2-6d R08 8.3-6 Sh 16 R03 8.2-6e R08 8.3-6 Sh 17 R03 8.2-6f R08 8.3-6 Sh 18 R00 8.2-6g R08 8.3-6 Sh 19 R24 8.2-6h R08 8.3-6 Sh 20 R03 8.2-6j R08 8.3-6 Sh 21 R03 8.2-6k R08 8.3-6 Sh 22 R03 8.2-6l R08 8.3-6 Sh 23 R00 8.2-6m R08 8.3-6 Sh 24 R00 8.2-6n R08 8.3-6 Sh 25 R25 8.2-6o R08 8.3-6 Sh 26 R00 8.2-6p R08 8.3-6 Sh 27 R25 8.2-6q R08 8.3-6 Sh 28 R03 8.2-6r R08 8.3-6 Sh 29 R03 8.2-6s R08 8.3-6 Sh 30 R00 8.2-6t R08 8.3-6 Sh 31 R00 8.2-6u R08 8.3-7 R01 8.2-7 R23 8.3-8 Sh 1 R00 8.2-8 R23 8.3-8 Sh 2 R00 8.2-9 R08 8.3-8A R00 8.3-1 R25 8.3-8B Sh 1 A15 8.3-2 R25 8.3-8B Sh 2 A15 8.3-3 Sh 1 R24 8.3-8B Sh 3 A15 8.3-3 Sh 2 R25 8.3-8B Sh 4 A15 8.3-4 R17 8.3-8B Sh 5 A15 8.3-5 R00 8.3-8B Sh 6 A15 8.3-6 Sh 1 R00 8.3-8B Sh 7 A15

NMP Unit 2 USAR CHAPTER 8 LIST OF EFFECTIVE FIGURES (contd.)

Chapter 08 EF 8-2 Rev. 25, October 2022 Revision Revision Figure No.

Number Figure No.

Number 8.3-8B Sh 8 A15 8.3-8B Sh 9 A15 8.3-8B Sh 10 A15 8.3-8B Sh 11 A15 8.3-8B Sh 12 R08 8.3-8B Sh 13 A23 8.3-8B Sh 13a A28 8.3-8B Sh 13b A28 8.3-8B Sh 13c A28 8.3-8B Sh 13d A28 8.3-8B Sh 13e A28 8.3-8B Sh 13e1 A28 8.3-8B Sh 13f A28 8.3-9 R04 8.3-10 R17 8.3-11 R09

NMP Unit 2 USAR CHAPTER 8 TABLE OF CONTENTS Section Title Chapter 08 8-i Rev. 25, October 2022

8.1 INTRODUCTION

8.1.1 Utility Grid 8.1.2 Interconnections 8.1.3 Offsite Power System 8.1.4 Onsite Ac Power System 8.1.5 Dc Power System 8.1.6 Uninterruptible Power Supply System 8.1.7 Design Criteria for Plant Auxiliary Power System 8.2 OFFSITE POWER SYSTEM 8.2.1 Description 8.2.1.1 Grid System 8.2.1.2 Main Generator 8.2.1.3 345-kV Switchyard and Generator Step-up Transformer 8.2.1.4 115-kV Switchyard 8.2.1.5 Protection System 8.2.1.6 Instrumentation and Control 8.2.1.7 Switchyard Dc Power Supply 8.2.1.8 Inspection and Testing 8.2.2 Analysis 8.3 ONSITE POWER SYSTEM 8.3.1 Ac Power System 8.3.1.1 Description 8.3.1.1.1 Systems and Identification 8.3.1.1.2 Power Supply Buses 8.3.1.1.3 Reactor Protection System Power Supply 8.3.1.1.4 Cables and Raceways 8.3.1.1.5 Containment Electrical Penetrations 8.3.1.1.6 Safety-Related Motors 8.3.1.1.7 Criteria for Interrupting Capacity of Class 1E Switchgear, Load Centers, Motor Control Centers, and Distribution Panels 8.3.1.1.8 Electric Circuit Protection 8.3.1.1.9 Grounding of Class 1E Systems 8.3.1.1.10 Periodic Testing and Maintenance 8.3.1.2 Analysis 8.3.1.3 Physical Identification of Safety-Related Equipment 8.3.1.3.1 Color Coding 8.3.1.3.2 Alphanumeric Coding 8.3.1.4 Independence of Redundant Systems 8.3.1.4.1 Electrical Isolation

NMP Unit 2 USAR CHAPTER 8 TABLE OF CONTENTS (Contd.)

Section Title Chapter 08 8-ii Rev. 25, October 2022 8.3.1.4.2 Physical Separation 8.3.1.5 Conformance with 10CFR50.63, Station Blackout Rule 8.3.1.5.1 Station Blackout Duration 8.3.1.5.2 Station Blackout Coping Capability 8.3.1.5.3 Procedure and Training 8.3.1.5.4 Quality Assurance 8.3.1.5.5 EDG Reliability Program 8.3.2 Dc Power System 8.3.2.1 Description 8.3.2.1.1 General 8.3.2.1.2 Safety-Related Dc Systems 8.3.2.1.3 Nonsafety-Related Dc Power System 8.3.2.2 Analysis 8.3.2.3 Physical Identification of Safety-Related Dc System Equipment 8.3.2.4 Independence of Redundant Systems 8.3.2.5 Station Blackout Capability 8.3.3 Fire Protection for Cable System 8.3.4 References APPENDIX 8A FLEXIBLE CONDUIT AND FIRE-RETARDANT TAPE AS SEPARATION BARRIERS

NMP Unit 2 USAR CHAPTER 8 LIST OF TABLES Table Number Title Chapter 08 8-iii Rev. 25, October 2022 8.2-1 MINIMUM VOLTAGES AT VARIOUS EMERGENCY BUSES AND THEIR CONNECTED LOADS UNDER DIFFERENT LOADING CONDITIONS 8.3-1 DELETED 8.3-2 DELETED 8.3-3 DELETED 8.3-3A HPCS DIESEL GENERATOR CONDITIONS AND CORRESPONDING MAIN CONTROL ROOM ANNUNCIATIONS 8.3-4 LIST OF CLASS 1E SAFETY-RELATED LOADS BY POWER SOURCE 8.3-5 DELETED 8.3-6 DELETED 8.3-6a ANNUNCIATOR WINDOWS FOR THE DIESEL GENERATORS DISPLAYED IN CONTROL ROOM 8.3-7 CABLE SERVICE LEVELS AND TRAY FILL REQUIREMENTS 8.3-8 DIVISION I 125-V DC BATTERY 2BYS*BAT2A LOAD PROFILE 8.3-9 DIVISION II 125-V DC BATTERY 2BYS*BAT2B LOAD PROFILE 8.3-10 DIVISION III 125-V DC BATTERY 2BYS*BAT2C LOAD PROFILE 8.3-11 NORMAL 125-V DC BATTERY 2BYS-BAT1A LOAD PROFILE 8.3-12 NORMAL 125-V DC BATTERY 2BYS-BAT1B LOAD PROFILE 8.3-13 NORMAL 125-V DC BATTERY 2BYS-BAT1C LOAD PROFILE 8.3-14 NORMAL 24-V BATTERY 2BWS-BAT3A AND 3C LOAD PROFILE

NMP Unit 2 USAR CHAPTER 8 LIST OF TABLES (Contd.)

Table Number Title Chapter 08 8-iv Rev. 25, October 2022 8.3-15 NORMAL 24-V BATTERY 2BWS-BAT3B AND 3D LOAD PROFILE

NMP Unit 2 USAR CHAPTER 8 LIST OF FIGURES Figure Number Title Chapter 08 8-v Rev. 25, October 2022 8.1-1 NEW YORK POWER POOL 8.2-1 SITE TRANSMISSION NETWORK 8.2-1a UNIT 2 - VOLNEY TO UNIT 2 TRANSMISSION RIGHT OF WAY 8.2-1b TRANSMISSION PROJECT 8.2-1c SCRIBA STATION: STATION SERVICE 8.2-2 345 KV TRANSMISSION TOWER - 1 STEEL POLE STRUCTURE TYPE 345 KV ST 1.4 DE-TS 8.2-3 345 SINGLE CIRCUIT - 3 STEEL POLE STRUCTURE TYPE 345 KV ST 1.4 DE-TS-3P 8.2-4 115 KV TRANSMISSION TOWERS - SINGLE CIRCUIT - 3 STEEL POLE STRUCTURE TYPE 115 KV DE 8.2-5 115 KV TRANSMISSION TOWERS - TWO POLE TANGENT "H" FRAME - TYPE D-1331 8.2-5a 115 KV TRANSMISSION TOWERS - TWO POLE TANGENT "H" FRAME - TYPE D-1332 8.2-6 115 KV TRANSMISSION TOWERS - SINGLE CIRCUIT STEEL POLE TYPE SU 1.1 TS & SU 1.31 TS 8.2-6a 115 KV TRANSMISSION TOWERS - SINGLE CIRCUIT STEEL POLE TYPE ST 1.2 DE-TS & ST 1.3 DE-TS 8.2-6b 115 KV TRANSMISSION TOWERS - 3 WOOD POLE STRUCTURE 8.2-6c 115 KV TRANSMISSION TOWERS - 3 POLE ANGLE STRUCTURE 0°-90° STRUCTURE TYPE D-1335 8.2-6d 115 KV TRANSMISSION TOWER - 1 STEEL FLEX TOWER TYPE "C" 8.2-6e 115 KV TRANSMISSION STRUCTURE - THREE POLE DEAD END TAP STRUCTURE 45°-90°

NMP Unit 2 USAR CHAPTER 8 LIST OF FIGURES (Contd.)

Figure Number Title Chapter 08 8-vi Rev. 25, October 2022 8.2-6f 115 KV TRANSMISSION STRUCTURE - THREE POLE TERMINAL DEAD END STRUCTURE TYPE D-1336A (MODIFIED) 8.2-6g 345/115 KV TRANSMISSION TOWER - 1 STEEL POLE STRUCTURE TYPE 345 KV ST 2.1 TS 8.2-6h 345/115 KV TRANSMISSION TOWER - 1 STEEL POLE STRUCTURE TYPE 345 KV SU 2.1 TS 8.2-6i 345/115 KV TRANSMISSION TOWER - 1 STEEL POLE DEAD END STRUCTURE TYPE 115 KV ST 1.4 DE-TS 8.2-6j 115 KV TRANSMISSION STRUCTURE - 3 STEEL POLE DEAD END ANGLE STRUCTURE TYPE 115 KV ST 1.6 DE TS-3P 8.2-6k 115 KV TRANSMISSION STRUCTURE - THREE POLE STRUCTURE 8.2-6L 115 KV TRANSMISSION STRUCTURE - TWO POLE TANGENT "H" FRAME TYPE D-1330A (MODIFIED) 8.2-6m 115 KV TRANSMISSION STRUCTURE - THREE POLE STRAIN STRUCTURE 8.2-6n 115 KV TRANSMISSION STRUCTURE - SINGLE POLE -

VERTICAL DEAD END TAP STRUCTURE 8.2-6o 115 KV TRANSMISSION STRUCTURE - THREE POLE DEAD END STRUCTURE 0°-90° 8.2-6p 115 KV TRANSMISSION STRUCTURE - TWO POLE TANGENT "H" FRAME TYPE D-1331A 8.2-6q 115 KV TRANSMISSION STRUCTURE - THREE POLE STRAIN TAP STRUCTURE 8.2-6r 115 KV TRANSMISSION STRUCTURE - TWO POLE TANGENT STRAIN "H" FRAME TYPE D-1337A 8.2-6s 115 KV TRANSMISSION STRUCTURE - THREE POLE TANGENT STRAIN STRUCTURE 8.2-6t 115 KV TRANSMISSION STRUCTURE - THREE POLE DEAD END STRUCTURE 8.2-6u 115 KV TRANSMISSION STRUCTURE - SINGLE POLE DEAD END TAP STRUCTURE TYPE D-1304A

NMP Unit 2 USAR CHAPTER 8 LIST OF FIGURES (Contd.)

Figure Number Title Chapter 08 8-vii Rev. 25, October 2022 8.2-7 345 KV SWYD ONE LINE DIAGRAM 8.2-8 115 KV SWITCHYARD 8.2-9 NMPC GRID 8.3-1 PLANT MASTER ONE LINE DIAGRAM, NORMAL POWER DISTRIBUTION 8.3-2 PLANT MASTER ONE LINE DIAGRAM, EMERGENCY POWER DISTRIBUTION 8.3-3 PLANT MASTER ONE LINE DIAGRAM, NORMAL 600V AND 120V AC (SHEETS 1 AND 2) 8.3-4 PLANT MASTER ONE LINE DIAGRAM, EMERGENCY 600V AND 120V AC 8.3-5 25 KVA SINGLE PHASE UNINTERRUPTIBLE POWER SUPPLY SYSTEM 8.3-6 STANDBY DIESEL GENERATOR CONTROL AND PROTECTION LOGICS (SHEETS 1 THROUGH 31) 8.3-7 REACTOR PROTECTION SYSTEM MG SET CONTROL 8.3-8 ELECTRICAL PENETRATIONS MEDIUM VOLTAGE (TYPICAL)

Sh. 1 8.3-8 ELECTRICAL PENETRATIONS LOW VOLTAGE (TYPICAL)

Sh. 2 8.3-8A PENETRATION I2t CAPABILITY 8.3-8B PENETRATION PROTECTION (SHEETS 1 THROUGH 13F) 8.3-9 DELETED 8.3-10 PLANT MASTER ONE LINE DIAGRAM, EMERGENCY 125V DC SYSTEM AND NORMAL +/-24V DC SYSTEM 8.3-11 PLANT MASTER ONE LINE DIAGRAM, NORMAL 125V DC SYSTEM