ML22278A817
Text
.
1-
- c
~
H G
F E
D c
B A
8 8031-M-56 8
SH. 1 OF TURBll'<IE SPEED
~-
<SH.3 H, ll 7
I I
I I
LOW PUMP SUCTION PRESSURE
_j r
HIGH TURBIN~HAUST PRESSURE -- --
r - - - - - - - -,
r- - -----) REF I t..- -
) REF 2 7
REACTOR VESSEL HIGH WATER LEVEL I
AUTO ISOLATION SIGNAL I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I 6
2' HBB-115 1',D-1561 Y'
DAW Ji* HBB-110 I Yi HBB-110 Y'
ORW Y'
ORW 6
5
~
4 VENT TO HPCI COMPARTMENT 3
2 TURBll'<IE HYDRAULIC COl'<ITROL SYSTEt.t EGM OUTPUT
~----
~
~~RAMP I,----- - - - - -
GENERATOR I
OUTPUT t
I C201 C201 HS HS I
C847 t STEAM SUPPLY C647 0*
~
H2
[;] I I __ _
I L_
&______.L___;fo\
w--~
L TURBINE CONTROL LOGIC REFERENCE 2 & REFERENCE 1 I 10" EBB-lOB M-55
<SH.I D,31 I
I I
I C618 L
W IS*
COl-4 IO" 900* ANSI SG FLANGE z
"' a:
0 6....
~~
u a:
Y' ORW BOOSTER PUt.tP N - z dJ 4
"' 0:
<.> 0 Y'
DAW HPCJ PUt.tP IOP204*
1C001
!NOTE Bl DRIVE SHAFT 12*
- Y' ORW Ji,* SBD-156 I SUCTION t VENT ~
DAW 14' EBB-129 20' HBB-108 1
INGSSS L-~
~
C014 PT INOSIF r-~---;
1 ~
r--w DRIVE SHAFT PSE 10003 IFD99 1F06i_
~ z
<(iJE!>~ ~
Y' ORW Y' Y' ORW DRW 1" HBB-113 Ji,* SBD-156 Y'
DRW
~~.
~
o~
ORAll'<I POT~~
r.i=
I' HBB-108 CASING DRAIN Ji* HBS-108 HPCI TURBINE
""iOS2ii
- iCo'02""
<NOTE 8 & 151
(,)
(,)
SEAT &
CHEST DRAINS f.:l CB47
~
1---1--
HV IF059 C647
~
~
-L.-SREF 2 1
CGl8 PIS
- INGIGF
- ?
Y2'
~
RVL-113 f--] DRAIN BAROt.tETRIC CONOEl'<ISER
~
I PCV N'-..~----..... ~~~-IF_Q_35~--f)l()-:.*~~~.._..,._...-.....-.._--jL8~~~"-~~...l~~~~~-"'-*N..&.~-~
..... ~-;,.,-N..&.~-~.... ~{)
2' HBB-IOB r-CB47
~
~
2" HBB-108 i
Y' ORW 2'
1F048
~
- J DRAIN
~
Dh LUBE OIL COOLER
~
I0E213*
DRAIN ~--tI..----1 1043 r---
1 C647 I
I
~
_J I
I I
I I r-1 2*
I IFOS2
_L __ _
IF058 1065 LOCKED THROTTLED
-1 I
_J C647 C647 1--fili HPCI VACUUM TANK CONDENSATE PUt.tP IOP215
- TEST ~--lllt----1 HV-IF026<ASJ
<SH~~~\8, ~ I ac I
1F043
:-1
~~-f)--.,p--,~~~-tl(]---<M-M-T515('. I I
~..
HV-1F02S<ASI ISH.J4 B,Bl 1 !
~z
~l l
V1 Q
REF 2 DRW VACUUt.I TANK Ji* SBD-156 a;~
O LU
~....
-o z
Y' ORW TO REACTOR ENCLOSURE EQUIPMENT COMPARTMENT EXHAUST 5
4 3
/
HPCI BAROMfiRIC CONDENSER VACuut.t
""""Pijijji"""
IOP216*
1' HBB-108 1' HBB-108 1" HBB-108 I
_J Cb47
~
~
L Y'
ORW
SREF 2 2
REF No.
REFERENCE DRAWINGS BECHTEL No.
GE No.
1 NUCLEAR BOILER P&ID M-4 I HPCI FUNTIONAL CONTROL DIAGRAM 603HAl-E41-1030-F 729E627AD HPCI PUMP/TURBINE P&ID M-56 1--+-----------+---------t-------1 P&ID LEGEND M-00 CORE SPRAY PidO M-52 RCIC P&ID M-49 AUXILIARY STEAM P&ID M-21 MAIN STEAM P&IO M-01 CONDENSATE P&ID M-05 11 TURBINE CONTROLS DIAGRAM B031-Ml-E41-C002-K VPF 2763-92-1 12 HPCI SYSTEM P&ID B03H<l-E41-IOIO-D 761E230AO 22Al732 14 HPCI SYSTEM DESIGN SPEC BOlHAl-E<l-4010-L 22Al021 8031-M-B30 NA I.
HPCI IS A SEISMIC CATEGORY I SYSTEM EXCEPT AS NOTED.
- 2.
AC POWER FOR HPCI INSTRUMENTS SHALL 8£ DERIVED FROM THE PLANT DC POWER SYSTEM, VIA AN INVERTER. THE DC SOURCE IS TO BE SEPARATE FROM THAT WHICH SUPPLIES THE RCIC SYSTEM.
- 3.
THE GE MPL NUMBER FOR THIS SYSTEM IS E-41.
- 4.
THE BAROMETRIC CONDENSER AND VACUUM TANK SHALL BE LOCATED SO THAT ITS WATER LEVEL IS BELOW THE BOTTOM OF THE TURBINE EXHAUST.
- 5.
ALL INSTRUMENT PIPING ANO TUBING SHALL BE INSTALLED IN ACCORDANCE WITH REFERENCE 13. FOR DEVIATIONS TO SLOPE CRITERIA SEE REF. 15.
- 6.
All STEAM L!NES SHALL BE SLOPED WHERE PRACTICAL.
- 7.
NON-0 DRAIN ANO VENT LINES AND CAPPED ENDS EXTENDING FROM SEISMIC CATEGORY I PIPING ARE SEISMIC CATEGORY IIA DOWNSTREAM OF THE LAST ISOLATION VALVE.
- 8.
THIS EQUIPMENT IF,3-51 IS BEING MONITORED BY THE VIBRATION MONITORING SYTEM IVMSI. FOR THE TYPE OF SENSORS BEING USED, SEE VMS 1/0
SUMMARY
, VP DWG 8031-M-247-108,
- 9.
PORTION OF THE HBB-110 SUCTION LINE FROM THE PUMP TO TH[ FLANGE MAY BE TESTED AT THE SAME PRESSURE AS GBB-125. IF,61 IO.
DELETED.
- 11.
FOR ALL NON-SEISMIC CATEGORY I CAPPED VENTS. DRAINS, ANO TEST CONNECTIONS, DESIGN, FABRICATION, MATERIAL PROCUREMENT, ERECTION AND TESTING FOR ALL PIPING DOWNSTREAM OF THE LAST ISOLATION VALVE MAY BE IN ACCORDANCE WITH DESIGN CODE "O'.
- 12.
DELETED.
- 13.
FOR ALL SEISMIC CATEGORY !IA HBB-113 PIPING DOWNSTREAM OF FO-IDOll ANO PSE-10004: DESIGN, FABRICATION, MATERIAL PROCUREMENT, ERECTION AND TESTING MAY BE IN ACCORDANCE W!TH PIPING CLASS DESIGNATION, DESIGN CODE 'D' IH,41.
- 14.
REMOVE VALVE INTERNALS FROM BAROMETRIC CONDENSER VACUUM PUMP DISCHARGE LINE CHECK VALVE 1F081 IA,3J, PER MOCP-614.
IS.
PERMANENT REMOVAL OF ONE "ACTIVE' CARBON RING PER HPCI TURBINE GLAND IS ACCEPTABLE PER LG ECR 05-00126.
- 16.
- DELETED,
- 17.
POINT CONNECTIONS SHOWN ON DRAWING H12-P614-E-002 SHT,I, II INCORP. ECR LG 13-00310 REV.3 PER W/O C025B360.
w D >-
Z"'
0 ADDED NOTE < 6.
AT iE-ll.
INCORP. ECR LG 05-00126 R/D PER W/O C02130B6.
15 AND A REFERENCE TO IT DESCRIPTION TABLE OF AODITIONS & CHANGES USE ONLY PRINTS SHOWING LATEST DATE MECHANICAL P&ID HPCI PUMP/TURBINE J
JC NT H
G F
E D
c (UNIT 1>
1--~~~~L-lt.t_E_R-IC_K_G_E_NE_R_A_T_ING~S-T_A_Tl_O_N~~~--tA EXELON NUCLEAR CORP.
SCALE DRAWN
!GOS CHECKED INSPECTED APPROVED DATE NONE BECHTEL BECHTEL BECHTEL BECHTEL BECH BECH 01/:31/'Jl APPROVED BECHTEL APPROVED SHEET OF 8031-M-56 E 43 I CA TE GORY A 1