6 to Updated Final Safety Analysis Report, Figure 3.2-21, Sheet 5 of 35, Drawing 102021-4, Diesel Engine Generator Associated Systems
ML21305A738
Person / Time
Site: Diablo Canyon  Pacific Gas & Electric icon.png
Issue date: 10/11/2021
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21306A142 List: ... further results
References
DCL-21-074
Download: ML21305A738 (1)


Text

40 41 42 43 44 45 56 47 48 49

oc-t,63082-72 /41'( 1 ?- TO ENG I NE E CONTROL PANEL E

TO UNLOADER AIR INTAKE FROM ~

r.7 ENG-GEN" ROOM ~ GIZ) 0 RV-387 SWAGELOCK SS-4P4T D

~ I - I TURBO CHARGER AIR SV-5 4~7 ON DIESEL ENGINE COMPRESSOR {fAV 2. ~ DC-663082-31 I - I DC-6630f?c-72 DC-663082-18 C TURBO CHARGER AIR ASSIST SYSTEM C

~ [:,.l.-..L---~~-:-:-::-......-..,,..........-::] TYPICAL FOR THREE ENG, GEN UNITS UNIT UNIT ITEM /\\ I REF, DWG, DC-663082-31 UNIT,-, SPEC 1166 REF, DWG, DC-437667-1 (ELECTRICAL)

.SER Vi(E /-2 /-3 S/C 95-4677 &

AIA. lOMP. DISC.ti, f-lEAD RV 367 388 38'1 ON I -3

!\\EL.IE F VALVE £ I,* DENOTES MANUFACTURER SUPPLIED INSTRUMENTS AND EQUIPMENT, IT IS ACCEPTABLE TO REPLACE Al 317 318 319 MANUFACTURER SUPPLIED INSTRUMENT TUBING WITH PG&E SUPPLIED S-SPEC STAINLESS STEEL TUBING AIR RECEIVER PRESSURE Pl 8'40 84/ 8'42 TURBO CHARGER AIR ASSIST I ND I CA TORS 2, FIELD PIPING THIS SYSTEM SHALL BE PG&E CLASS IT] UNLESS NOTED INLET PRESS" I ND I CA TOR 8'4 3 844 8'4 5

- B AIR COM!=-~E= S$OR 3, AIR RECEIVER OUTLET STRAINERS BE INSTALLED HORIZONTALLY <46-D/E) B 0 PS 312. 313 314 N START PRE.SS. 5.AIITCH 4, MOUNTED ON ENGINE CONTROL PANEL <TI])

I 0 AIR REC.E/VER RV c99 RELi EF VAL-YES 2.97 2.98 5, ALL VALVE ON THIS SHEET WITH PG&E ITEM NOS, SHALL BE UNDER SPEC 8729 I

0 (DWG 102039), UNLESS NOTED,<41/45/46-C&D)

00 Q)

C +- TURBO Cl!AR6ER {A SY 505 501 DELETED Al CTI 0 INLET.SOLENOID B &

u 0 oc VALVES 500 506 IF GLOBE VALVES s;;r CTI (IJU INDICATING FLOW ARE INSTALLED THE PREFERRED ORIENTATION IS WITH THE FLOW ARROW TOWARDS THE AIR COMPRESSOR, <TI])

- o----:J AIR COMPRES N7LL it LUBE OIL D /\\5 o(f)----:i A VALVE & 8, FIBERGLASS BLANKET TYPE PERSONNEL PROTECTION INSULATION, LJ NIT N-<( A oN "" ~ DIABLO CANYON POWER PLANT - PG&E CO"

-OL 36 11 N Q) A\\R RcCEIIIER. f STA_ 4LI 83 DIESEL ENGINE-GENERATOR ASSOCIATED SYSTEMS er: 0 U) OUTLET SiA.AI.\\Jf ~ B w-=::i 37 45 84 DRAWING SHEET PAGE REV f-11 VJ Z 0

<( C) <( 102021 4 0 62 er: 0 U INPGIC I Size I O f---------+------+----+-------+-----------------+------f---------+------------l - I O - 2 0 I I A J F J R xG 2 K ER S I J, DA L A L MECH AN I CA L M I 6 6 9 0 3 / 3 I / 2 0 I 2 R EV I S ED P ER D F T - 7

  • I 3 0 3 DATE OWN RE IV PROFESSIONAL ENGINEER PE DISCO PE"" PE EXPO