1. Transmittal Letter Request for Supplemental Information, Model No. Castor(R) geo69 Storage Cask Design
ML21266A241
Person / Time
Site: 07201052
Issue date: 10/18/2021
From: Garcia-Santos N
Storage and Transportation Licensing Branch
To: Bussmann D
Gesellschaft fur Nuklear-Service mbH
N Garcia Santos NMSS/DFM/STL 301-4156999
Shared Package
ML21266A240 List:
References
EPID L-2021-NEW-0006
Download: ML21266A241 (4)


Text

OFFICIAL USE ONLY - PROPRIETARY INFORMATION Mr. Dominik Bussmann, Licensing Manager Gesellschaft für Nuklear-Service mbH Frohnhauser Strae 67 45127 Essen Germany

SUBJECT:

REQUEST FOR CERTIFICATE OF COMPLIANCE FOR THE MODEL NO.

CASTOR GEO69 STORAGE CASK - REQUEST FOR SUPPLEMENTAL INFORMATION

Dear Mr. Bussmann:

By letter dated June 7, 2021 (Agencywide Documents Access and Management System Accession No. ML21188A178), Gesellschaft für Nuklear-Service mbH submitted an application for a certificate of compliance for the Model No. CASTOR geo69 storage cask. The U.S.

Nuclear Regulatory Commission staff performed an acceptance review of your application to determine whether the application contains sufficient technical information in scope and depth to allow the staff to complete a detailed technical review.

This letter is to advise you that, based on our acceptance review, the application does not contain sufficient technical information. The information needed to continue our review is described as a request for supplemental information (RSI) in the enclosures to this letter.

Please note that addressing this RSI does not preclude the staff from issuing further requests for additional information during the course of the detailed technical review of this application.

The staff also included observations to allow you to start earlier on items that may be asked at a later date. Observations are not the result of a detailed technical review and may be resolved once staff begins a detailed review. Responses to observations are not required for staff to begin its technical review.

In order to schedule our technical review, the RSI response should be provided within 8 weeks from the date of this letter. If the RSI responses are not received by this date, the application may not be accepted for review and the staff may discontinue any further review.

OFFICIAL USE ONLY - PROPRIETARY INFORMATION Upon removal of Enclosure 2, this document is uncontrolled.

October 18, 2021

D. Bussmann OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION Please reference Docket No. 72-1052 and Enterprise Project Identifier (EPID) No. L-2021-NEW-0006 in future correspondence related to this request. The staff is available to meet to discuss your proposed responses. If you have any questions, I may be contacted at

+1 (301) 415-6999 or via email at Norma.GarciaSantos@nrc.gov.

Sincerely, Norma García Santos, Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 72-1052 EPID No. L-2021-NEW-0006

Enclosures:

1. Non-proprietary RSI
2. Proprietary RSI Signed by Garcia Santos, Norma on 10/18/21

ML21266A240 (pkg)

Office NMSS/DFM NMSS/DFM NMSS/DFM NMSS/DFM NMSS/DFM Name NGarcía-Santos WWheatley JWoodfield PPatel OKhan Date 9/ 24 /2021 9/ 24 /2021 9/ 27 /2021 10/4 /2021 9/ 30 /2021 Office NMSS/DFM NMSS/DFM NMSS/DFM NMSS/DFM NMSS/DFM Name ASotoMayor-Rivera JBorowsky CBajwa TBoyce FPeduzzi Date 9/ 30 /2021 9/ 30 /2021 9/ 29 /2021 10/ 4 /2021 10/ 7 /2021 Office NMSS/DFM NMSS/DFM NMSS/DFM Name ZCruz-Perez JMarcano JMcKirgan Date 10/ 4 /2021 10/ 7 /2021 10/ 15 /2021

ML21266A240; Ltr ML21266A241 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/STLB NAME NGarcia BWhite WWheatley BWhite DATE Sep 24, 2021 Sep 24, 2021 Sep 24, 2021 Sep 24, 2021 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/STLB NAME BWhite BWhite JMcKirgan NGarcia DATE Oct 4, 2021 Oct 7, 2021 Oct 15, 2021 Oct 18, 2021