Comment (007) of Marcus Nichol on Behalf of the Nuclear Energy Institute on PR-2,21,26,50,51,52,55,73 - Alignment of Licensing Processes and Lessons Learned from New Reactor Licensing
ML21265A444
Person / Time
Site: Nuclear Energy Institute
Issue date: 09/15/2021
From: Nichol M
Nuclear Energy Institute
To:
SECY/RAS
References
86FR7513, NRC-2009-0196, PR-2, PR-21, PR-26, PR-50, PR-73, RIN 3150-A166
Download: ML21265A444 (42)


Text

From: NICHOL, Marcus To: RulemakingComments Resource Cc: Veil, Andrea; Coyne, Kevin; Taylor, Robert; Smith - NRR, Brian; O"Driscoll, James; Fetter, Allen

Subject:

[External_Sender] Additional Industry Comments on the Regulatory Basis for Alignment of Licensing Processes and Lessons Learned from New Reactor Licensing (Docket ID: NRC-2009-0196)

Date: Wednesday, September 22, 2021 7:17:51 AM Attachments: 09-22-21_NRC_NEI Additional Comments on Draft Regulatory Basis.pdf NEI Letter and Paper on Non-Applicable Regulations (ML20308A662).pdf September 22, 2021 Office of Administration MS TWFN-7A06 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Attn: Program Management, Announcements and Editing Staff

Subject:

Additional Industry Comments on the Regulatory Basis for Alignment of Licensing Processes and Lessons Learned from New Reactor Licensing (Docket ID: NRC-2009-0196)

Submitted via email to Rulemaking.Comments@nrc.gov Project Number: 689

Dear Program Management,

Announcements and Editing Staff:

On behalf of the Nuclear Energy Institutes (NEI) members (hereinafter referred to as industry),

we provide the following supplemental comment on the NRCs draft Regulatory Basis for Alignment of Licensing Processes and Lessons Learned from New Reactor Licensing (Agencywide Documents Access and Management System (ADAMS) Accession No. ML20149K680) (draft Regulatory Basis). In our May 14, 2021 comments (ADAMS Accession No. ML21144A164) we commended the staffs efforts to address the lessons learned from Part 52 licensing activities as a part of the development of the draft regulatory basis and noted that the staff should make every effort to take advantage of this once in a decade opportunity to improve the regulations to be less burdensome while still assuring a high level of safety. Specifically, this comment supplements our earlier comments 2, 31, and response to Question 5 in the Federal Register Notice, where we expressed the need for the Part 50/52 Lessons Learned Rulemaking to 1) clarify the requirements that are not applicable to non-light-water reactors, and 2) ensure consistency in the treatment of non-applicable requirements in the Part 50 and Part 52 licensing processes.

In parallel, industry has been engaged with NRC staff in the Division of Advanced Reactors and Non-Power Production and Utilization Facilities (DANU) on the same topic in efforts to prepare an efficient pathway for the NRC review and licensing of non-light water reactors (non-LWRs). On October 30, 2020, NEI provided feedback (Accession No. ML20308A662) on an NRC draft white paper, Analysis of Applicability of NRC Regulations for Non-Light Water Reactors (Accession No. ML20241A017) (draft white paper). Following public meeting discussions, NRC staff issued an

appendix to the draft white paper (ADAMS Accession No. ML21049A098), that provided additional information on how to document compliance and request exemptions, and sent NEI a response to our letter on July 29, 2021 (ADAMS Accession No. ML21158A118) (NRCs response). In the NRCs response, staff acknowledged that certain regulatory requirements differ between 10 CFR Part 50 and 10 CFR Part 52. Some of these differences are due to NRCs expectation that most new reactor applicants would use 10 CFR Part 52, rather than 10 CFR Part 50, to construct and operate new reactor facilities. The ongoing rulemaking to clarify Parts 50 and 52 and their interrelationship (RIN 3150-AI66) is expected to ensure consistency in new reactor licensing reviews as well as address other new reactor licensing issues.

We agree with the NRC Staff that the Part 50/52 lessons learned rulemaking should be used to address the issue of non-applicable regulations. Therefore, we submit the following as a supplemental comment on the NRCs draft Regulatory Basis to ensure that the details of our positions submitted to DANU on the clarity of Parts 50 and 52 to address challenges related to the non-applicability of requirements for non-light water reactor designs are incorporated into the rulemaking. The following input is further detailed in our October 30, 2020 feedback to DANU (Accession No. ML20308A662), attached again for ease of reference.

The industry believes that NRC should clearly identify all regulations that are broadly not applicable to non-LWRs (using entry conditions, as needed). In determining whether a regulation is applicable or not applicable to non-LWRs, the NRC should base its determination on the technical aspects of the design and the underlying safety purpose of the regulation, neither of which changes based on the licensing process used (i.e., 10 CFR Part 50 versus 10 CFR Part 52).

As provided in the NRCs response, the staff has reviewed the regulations to determine whether any entry conditions not already identified are associated with a regulation listed in the tables in earlier drafts of the white paper, and whether any Three Mile Island items in 10 CFR Section 50.34(f) may be satisfied as a result of compliance with other regulations. The results of that review can be found in the latest revision of the white paper. Thus, the NRC staff found that they could not add entry conditions that were not already stated in the regulations. Therefore, the industry encourages the NRC to use the ongoing rulemaking to clarify Parts 50 and 52 and their interrelationship as the appropriate vehicle to clearly identify all regulations that are broadly not applicable to non-LWRs. NRC should propose additional entry conditions to include in the regulations such that the underlying safety purpose of each regulation is identified and applicability is considered within each regulation in light of the technical aspects of the design.

Successful clarification will result in consistent treatment of a given applicant irrespective of the choice to pursue Part 50 or Part 52 licensing.

We appreciate the NRCs effort in developing this draft and encourage your consideration of all stakeholder comments prior to finalizing the draft Regulatory Basis. We trust that you will find this comment useful and informative as you finalize the draft and we look forward to future engagement on this important matter. Please contact me at mrn@nei.org or 202.739.8131 or Kati Austgen at kra@nei.org 202.739.8068 with any questions or comments about the content of this letter.

Sincerely,

Marcus R. Nichol Senior Director New Reactors Nuclear Energy Institute 1201 F St NW, Suite 1100 Washington, DC 20004 www.nei.org

P: 202.739.8131 M: 202.316.4412 E: mrn@nei.org This electronic message transmission contains information from the Nuclear Energy Institute, Inc. The information is intended solely for the use of the addressee and its use by any other person is not authorized. If you are not the intended recipient, you have received this communication in error, and any review, use, disclosure, copying or distribution of the contents of this communication is strictly prohibited. If you have received this electronic transmission in error, please notify the sender immediately by telephone or by electronic mail and permanently delete the original message. IRS Circular 230 disclosure: To ensure compliance with requirements imposed by the IRS and other taxing authorities, we inform you that any tax advice contained in this communication (including any attachments) is not intended or written to be used, and cannot be used, for the purpose of (i) avoiding penalties that may be imposed on any taxpayer or (ii) promoting, marketing or recommending to another party any transaction or matter addressed herein.

MARCUS R. NICHOL Senior Director, New Reactors 1201 F Street, NW, Suite 1100 Washington, DC 20004 P: 202.739.8131 mrn@nei.org nei.org September 22, 2021 Office of Administration MS TWFN-7A06 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Attn: Program Management, Announcements and Editing Staff

Subject:

Additional Industry Comments on the Regulatory Basis for Alignment of Licensing Processes and Lessons Learned from New Reactor Licensing (Docket ID: NRC-2009-0196)

Submitted via email to Rulemaking.Comments@nrc.gov Project Number: 689

Dear Program Management,

Announcements and Editing Staff:

On behalf of the Nuclear Energy Institutes (NEI)1 members (hereinafter referred to as industry), we provide the following supplemental comment on the NRCs draft Regulatory Basis for Alignment of Licensing Processes and Lessons Learned from New Reactor Licensing (Agencywide Documents Access and Management System (ADAMS) Accession No. ML20149K680) (draft Regulatory Basis). In our May 14, 2021 comments (ADAMS Accession No. ML21144A164) we commended the staffs efforts to address the lessons learned from Part 52 licensing activities as a part of the development of the draft regulatory basis and noted that the staff should make every effort to take advantage of this once in a decade opportunity to improve the regulations to be less burdensome while still assuring a high level of safety. Specifically, this comment supplements our earlier comments 2 and 31, and response to Question 5 in the Federal Register Notice, where we expressed the need for the Part 50/52 Lessons Learned Rulemaking to 1) clarify the requirements that are not applicable to non-light-water reactors, and 2) ensure consistency in the treatment of non-applicable requirements in the Part 50 and Part 52 licensing processes.

1 The Nuclear Energy Institute (NEI) is responsible for establishing unified policy on behalf of its members relating to matters affecting the nuclear energy industry, including the regulatory aspects of generic operational and technical issues. NEIs members include entities licensed to operate commercial nuclear power plants in the United States, nuclear plant designers, major architect and engineering firms, fuel cycle facilities, nuclear materials licensees, and other organizations involved in the nuclear energy industry.

Program Management, Announcements and Editing Staff September 22, 2021 Page 2 In parallel, industry has been engaged with NRC staff in the Division of Advanced Reactors and Non-Power Production and Utilization Facilities (DANU) on the same topic in efforts to prepare an efficient pathway for the NRC review and licensing of non-light water reactors (non-LWRs). On October 30, 2020, NEI provided feedback (Accession No. ML20308A662) on an NRC draft white paper, Analysis of Applicability of NRC Regulations for Non-Light Water Reactors (Accession No. ML20241A017) (draft white paper). Following public meeting discussions, NRC staff issued an appendix to the draft white paper (ADAMS Accession No. ML21049A098), that provided additional information on how to document compliance and request exemptions, and sent NEI a response to our letter on July 29, 2021 (ADAMS Accession No. ML21158A118)

(NRCs response). In the NRCs response, staff acknowledged that certain regulatory requirements differ between 10 CFR Part 50 and 10 CFR Part 52. Some of these differences are due to NRCs expectation that most new reactor applicants would use 10 CFR Part 52, rather than 10 CFR Part 50, to construct and operate new reactor facilities. The ongoing rulemaking to clarify Parts 50 and 52 and their interrelationship (RIN 3150-AI66) is expected to ensure consistency in new reactor licensing reviews as well as address other new reactor licensing issues.

We agree with the NRC Staff that the Part 50/52 lessons learned rulemaking should be used to address the issue of non-applicable regulations. Therefore, we submit the following as a supplemental comment on the NRCs draft Regulatory Basis to ensure that the details of our positions submitted to DANU on the clarity of Parts 50 and 52 to address challenges related to the non-applicability of requirements for non-light water reactor designs are incorporated into the rulemaking. The following input is further detailed in our October 30, 2020 feedback to DANU (Accession No. ML20308A662), attached again for ease of reference.

The industry believes that NRC should clearly identify all regulations that are broadly not applicable to non-LWRs (using entry conditions, as needed). In determining whether a regulation is applicable or not applicable to non-LWRs, the NRC should base its determination on the technical aspects of the design and the underlying safety purpose of the regulation, neither of which changes based on the licensing process used (i.e., 10 CFR Part 50 versus 10 CFR Part 52). As provided in the NRCs response, the staff has reviewed the regulations to determine whether any entry conditions not already identified are associated with a regulation listed in the tables in earlier drafts of the white paper, and whether any Three Mile Island items in 10 CFR Section 50.34(f) may be satisfied as a result of compliance with other regulations. The results of that review can be found in the latest revision of the white paper. Thus, the NRC staff found that they could not add entry conditions that were not already stated in the regulations. Therefore, the industry encourages the NRC to use the ongoing rulemaking to clarify Parts 50 and 52 and their interrelationship as the appropriate vehicle to clearly identify all regulations that are broadly not applicable to non-LWRs. NRC should propose additional entry conditions to include in the regulations such that the underlying safety purpose of each regulation is identified and applicability is considered within each regulation in light of the technical aspects of the design. Successful clarification will result in consistent treatment of a given applicant irrespective of the choice to pursue Part 50 or Part 52 licensing.

Program Management, Announcements and Editing Staff September 22, 2021 Page 3 We appreciate the NRCs effort in developing this draft and encourage your consideration of all stakeholder comments prior to finalizing the draft Regulatory Basis. We trust that you will find this comment useful and informative as you finalize the draft and we look forward to future engagement on this important matter.

Please contact me at mrn@nei.org or 202.739.8131 or Kati Austgen at kra@nei.org 202.739.8068 with any questions or comments about the content of this letter.

Sincerely, Marcus R. Nichol Attachment c: Ms. Andrea Veil, NRR, NRC Mr. Kevin Coyne, NMSS, NRC Mr. Robert Taylor, NRR, NRC Mr. Brian Smith, NRR/DNRL, NRC Mr. James G. ODriscoll, NMSS, NRC Mr. Allen Fetter, NRR/DNRL, NRC

KATI R. AUSTGEN Senior Project Manager, New Reactors 1201 F Street, NW, Suite 1100 Washington, DC 20004 P: 202.739.8068 kra@nei.org nei.org October 30, 2020 Ms. Michelle W. Hayes Chief, Advanced Reactor Technical Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Subject:

NEI Input on Analysis of Applicability of NRC Regulations for Non-Light Water Reactors Project Number: 689

Dear Ms. Hayes:

The purpose of this letter is to provide the U.S. Nuclear Regulatory Commission (NRC) with the Nuclear Energy Institutes (NEI)1 input on the NRC Staff Draft White Paper Analysis of Applicability of NRC Regulations for Non-Light Water Reactors (Sept. 2020) (ML20241A017) (Draft White Paper). We are aligned with the NRC in the desire for a more efficient path for dispositioning regulations that are not applicable to non-light water reactors (non-LWRs). However, we are concerned that the Draft White Paper does not fully identify regulations that are not applicable to non-LWRs or clearly define a pathway to disposition these regulations without the need for an exemption. While we agree that in some cases exemptions will be required, the approach described in the NRCs Draft White Paper will likely require the extensive use of case-by-case exemptions.

Generically identifying regulations that do not apply to non-LWRs, and establishing an alternative to exemptions when they are not needed, will facilitate more streamlined non-LWR applications and more efficient NRC reviews by focusing the applications contents and the NRC staffs review thereof on the information that is directly relevant to the NRCs safety findings. If certain requirements are identified as either (1) not directly applicable to non-LWRs or (2) as specific to the characteristics of, or risk of events in, LWRs, then the underlying purpose of those regulations does not apply to non-LWRs. Consequently, compliance with those requirements is not necessary to support the NRCs required statutory findings (concerning adequate protection of the public health and safety and the common defense and security) under the Atomic Energy Act of 1954, as amended (AEA) and Title II of the Energy Reorganization Act of 1974 for non-LWRs. This is also consistent with the philosophy underlying the Commissions direction to the staff in SRM-SECY-19-0036: In any licensing review or other regulatory decision, the staff should apply risk-informed principles when strict, prescriptive application of deterministic criteria such as the single failure 1

The Nuclear Energy Institute (NEI) is responsible for establishing unified policy on behalf of its members relating to matters affecting the nuclear energy industry, including the regulatory aspects of generic operational and technical issues. NEIs members include entities licensed to operate commercial nuclear power plants in the United States, nuclear plant designers, major architect and engineering firms, fuel cycle facilities, nuclear materials licensees, and other organizations involved in the nuclear energy industry.

Ms. Michelle W. Hayes October 30, 2020 Page 2 criterion is unnecessary to provide for reasonable assurance of adequate protection of public health and safety.

Accordingly, in finalizing its Analysis of Applicability of NRC Regulations for Non-Light Water Reactors, we encourage the NRC to keep two overarching objectives in mind:

1. Clearly identify all regulations that are broadly not applicable to non-LWRs (using entry conditions, as needed). In determining whether a regulation is applicable or not applicable to non-LWRs, the NRC should base its determination on the technical aspects of the design and the underlying safety purpose of the regulation, neither of which changes based on the licensing process used (i.e., 10 CFR Part 50 versus 10 CFR Part 52).
2. Establish a process to address the regulations that are broadly not applicable to non-LWRs in a manner that minimizes the number of exemptions. This approach would provide consistency and predictability to the application process, as compared to expecting applicants to individually assess the entire body of regulations, and to seek numerous specific exemptions.

We discuss each of these two objectives in greater detail below.

A. Objective 1: Clearly identify all regulations that are broadly not applicable to non-LWRs.

The regulations in 10 CFR Part 50 and 10 CFR Part 52 were established around large light-water reactor (LWR) technology with prescriptive requirements that are specific to features of these designs. Non-LWRs differ substantially from LWRs and are expected to protect the public health and safety without the need for many of the features of LWRs. Thus, there are many regulations for which the underlying purpose does not apply to reactors that are not LWRs, because the purpose relates to design features that are not present in these designs. As such, non-LWRs need not comply with those regulations because they are not technically relevant and therefore are not relevant to the NRCs required safety findings.

The NRC should clearly identify all regulations that are broadly not applicable to non-LWRs (using entry conditions, as needed), and we appreciate the NRCs effort to document this in their draft White Paper.

The attached NEI paper was written to provide the industrys evaluation of the applicability of 10 CFR Part 52 content-of-application regulatory requirements to non-LWRs. It is not intended to be an exhaustive review of all regulatory requirements; it specifically focuses on the content-of-application requirements in 10 CFR 52.79 and associated Part 50 references. The majority of the regulations identified in the attached paper are listed in NRCs Table 2 - Part 52 Regulations Referencing Part 50 Regulations Limited to LWRs, in which the NRC staff has identified regulations that are applicable only to LWRs.

While we agree with much of the NRC staffs analysis of applicability, there are some regulations where we disagree with the NRCs conclusion that a regulation is applicable to non-LWRs. For example, 10 CFR 50.55a(a) should be identified as not applicable since the NRC staff acknowledges that it does not itself impose requirements. However, it remains identified as applicable to non-LWRs, implying that individual applicants should assess the list of standards, the vast majority of which have already been identified as not applicable.

We recognize that the applicability of some regulations to non-LWRs may depend on the specifics of a given reactor design. In such cases, the NRCs proposed use of entry conditions for ascertaining technical relevancy - as reflected in Table 4 - Applicability of 10 CFR 50.34(f) TMI Requirements to non-LWRs

Ms. Michelle W. Hayes October 30, 2020 Page 3 under Part 52 of the Draft White Paper - may be an acceptable performance-based solution. Therefore, we recommend that NRC consider expanding the use of such entry conditions in Table 4 for additional regulations that the NRC concludes cannot be deemed generically not applicable to non-LWRs. Additionally, several topical areas in Table 2 should be candidates for the use of performance-based entry conditions if they cannot be determined to be generically not applicable to non-LWRs, e.g., Analysis of Structures, Systems, and Components (SSCs) and Emergency Core Cooling System (ECCS) Evaluation, Station Blackout (SBO), Containment Leak Rate, and Reactor Vessel Surveillance Program.

B. Objective 2: Establish a process to address the regulations that are broadly not applicable to non-LWRs and minimize the number of exemptions required to the maximum extent practicable.

The NRCs Draft White Paper identifies several regulations that are not applicable to non-LWRs; however, the Draft White Paper is mostly silent on the process to disposition regulations identified as not applicable.

In the cases where the paper identifies a process, the NRC indicates that exemptions will be required. We are concerned that the NRCs approach is primarily focused on using the exemption process, which we believe is inefficient and, in most cases, not required. The NRC should establish a process to address the regulations that are broadly not applicable to non-LWRs in a manner that minimizes the number of exemptions. This approach would provide consistency and predictability in the application process, and minimize the need for non-LWR applicants to individually assess the entire body of regulations and/or seek numerous specific exemptions.

NEI recognizes that the NRC has a process for evaluating and granting exemptions from applicable requirements. An exemption is a Commission-granted dispensation from compliance with one or more of the Commissions rules and regulations which would otherwise apply to an entity, a license, permit or other approval such as a standard design certification rule. 2 However, we are concerned that the use of case-by-case exemptions from regulations that are not applicable to non-LWRs would be inefficient given the large volume of exemptions that would be needed under the staffs current proposed approach. 3 As Chairman Svinicki noted in a response to a question from Senator John Boozman in 2017:

[T]he NRC acknowledges the potential inefficiencies for non-LWR applications submitted under 10 CFR Part 50 or Part 52 that are reviewed against existing LWR requirements, using LWR-based processes, and licensed through the use of regulatory exemptions and imposition of new requirements where design-specific review, analysis, and additional engineering judgement may be required. The NRC's non-LWRs [sic] readiness activities are intended to address these potential inefficiencies and to provide increased regulatory certainty and predictability to non-LWR stakeholders. 4 2

Licenses, Certifications, and Approvals for Nuclear Power Plants; Final Rule, 72 Fed. Reg. 49,352, 49372 (Aug. 28, 2007) (emphasis added).

3 See Nuclear Innovation Alliance, Report on Strategies for Advanced Reactor Licensing, at 5, 52, 56 (Apr. 2016) (ADAMS Accession No. ML16104A147) (Advanced reactor designers from both traditional industrial organizations and small start-ups are concerned with the cost and schedule uncertainty associated with the exemption process (as well as potential negative perception that applicants are trying to avoid stringent safety regulation). As a result, they are hesitant to submit applications without first being assured that exemption requests will be meaningfully processed.).

4 Senate Committee on Environment and Public Works Hearing entitled "Oversight of the Nuclear Regulatory Commission" December 13, 2017 Questions for the Record, The Honorable John Boozman (Questions for Chairman Svinicki and Commissioners Baran and Burns)

(Response to Question 17), available at https://www.govinfo.gov/content/pkg/CHRG-115shrg28623/pdf/CHRG-115shrg28623.pdf.

Ms. Michelle W. Hayes October 30, 2020 Page 4 To avoid such inefficiencies, the NRC staff must establish clear, predictable, and efficient processes by which non-LWR applicants can demonstrate - without the repeated use of case-by-case exemptions - that certain regulations do not apply to their designs. While the NRC staff has determined that certain regulations are anticipated not to apply to non-LWRs (see NRC Tables 3 and 5 of the Draft White Paper), it is not clear how non-LWR applicants and NRC are expected to confirm and document that finding. Hence, we ask that the NRC work with stakeholders to identify a clearer and less complex process by which non-LWR applicants may document that a given regulation is not applicable to their reactor design, such that no exemption is required. We believe the rigid exemption process is not required to be exercised by non-LWR applicants and the NRC when it is clear that the purpose of the regulation does not apply to the design, and therefore does not trigger the need for an exemption pursuant to any of the special circumstance criteria listed in 10 CFR 50.12(a)(2). Notably, there is regulatory precedent for this approach; i.e., during case-specific reviews, the NRC has determined that exemptions were not necessary because the regulations in question were not applicable to the specific reactor design. In view of these considerations, and the additional information provided in the attached paper, NEI respectfully requests that the NRC Staff reexamine the premise that regulations that are not applicable to non-LWRs necessarily require exemptions from the regulations at issue for non-LWR designs.

Furthermore, the applicability of the underlying purpose of a technical requirement is not affected by the licensing process chosen, i.e., Part 50 or Part 52. We are concerned that the NRC intends to process non-applicable regulations for the same non-LWR applicant differently based on Part 50 or Part 52. As an example, we disagree with the NRC staff position that Part 52 regulations in Table 2 - Part 52 Regulations Referencing Part 50 Regulations Limited to LWRs necessarily require exemptions from the regulations for non-LWR designs. The Part 52 regulations at issue explicitly reference Part 50 regulations that the staff concedes do not apply to non-LWRs. We agree that these requirements are applicable only to LWRs; however, we disagree with the NRC staff conclusion that non-LWR applicants will need exemptions from these regulations. In the attached paper, we provide details supporting our position that because the underlying purpose of these regulations simply does not apply to non-LWRs as a class, they do not require exemptions. Engaging in case-by-case exemption analyses of whether the application of those regulations to non-LWRs would not serve the underlying purpose of the rule or is not necessary to achieve the underlying purpose of the rule (i.e., the likely relevant special circumstance under 10 CFR 50.12(a)(2)) 5 does not facilitate an optimally efficient and effective review. 6 Given the NRCs broad discretion under the AEA 7 and considerable flexibility under the Administrative Procedure Act to choose between rulemaking and adjudicatory procedures when making law, 8 we believe the staff can devise a more efficient approach that avoids what the Chairman described as licensing 5

10 CFR 50.12(a)(2)(ii). 10 CFR 52.7 cross-references the specific exemption criteria in 10 CFR 50.12.

6 Draft White Paper at 3.

7 See, e.g., Siegel v. AEC, 400 F.2d 778, 783 (D.C. Cir. 1968) (explaining that flexibility was a peculiar desideratum of the AEAs proponents, and that Congress agreed by enacting a regulatory scheme which is virtually unique in the degree to which broad responsibility is reposed in the administrating agency, free of close prescription in its charter as to how it shall proceed in achieving the statutory objectives); Ohio ex rel. Celebrezze v. NRC, 868 F.2d 810, 813 (6th Cir. 1989).

8 All Power Reactor Licensees & Research Reactor Licensees Who Transport Spent Nuclear Fuel, CLI-05-6, 61 NRC 37, 40-41 (2005) (citing NLRB v. Bell Aerospace Co., 416 U.S. 267 (1974); SEC v. Chenery Corp., 332 U.S. 194 (1947) (recognizing the need for regulatory flexibility and administrative efficiency and explaining that the Commission can tailor its requirements to the peculiar needs of individual licensees if necessary, and do so in a single adjudicatory proceeding).

Ms. Michelle W. Hayes October 30, 2020 Page 5 through the use of exemptions. NEI requests that the NRC reconsider whether it has examined all procedural alternatives to a case-by-case exemption approach for non-LWR applications and develop a timely alternative to the exemption process. These options include documenting a generic determination that can be referenced by applicants, or the use of hearing orders. 9,10 While rulemaking such as Part 53 will be valuable in the long term, we do not think it is a timely solution for near-term applicants. Accordingly, we request that NRC work with stakeholders to determine the best approach to disposition regulations that are not applicable to non-LWRs without the need for an exemption.

We appreciate the NRC staffs efforts on this issue and its consideration of the industrys related recommendations. If you have questions concerning the industrys input, please contact me.

Sincerely, Katherine R. Austgen Attachment c: Mr. Boyce W. Travis, NRR/DANU/UART, NRC Ms. Amy E. Cubbage, NRR/DANU/UARP, NRC Mr. John P. Segala, NRR/DANU/UARP, NRC Mr. Mohamed K. Shams, NRR/DANU, NRC 9

See SECY-20-0032, Rulemaking Plan on "Risk Informed, Technology-Inclusive Regulatory Framework for Advanced Reactors (RIN-3150-AK31; NRC-2019-0062)", at 5 (Apr. 13, 2020) (To accomplish this flexibility in the past, the Commission has used tools such as rules of particular applicability and hearing orders.).

10 The Commission previously has used hearing orders for individual licensing proceedings to clarify both applicable and non-applicable regulations and other requirements. See, e.g., Notice of Receipt of Application for License Notice of Availability of Applicant's Environmental Report; Notice of Consideration of Issuance of License; and Notice of Hearing and Commission Order; Louisiana Energy Services, LP.; Claiborne Enrichment Center, 56 Fed. Reg. 23,310 (May 21, 1991); Louisiana Energy Services, L.P. (National Enrichment Facility); Notice of Receipt of Application for License; Notice of Availability of Applicants Environmental Report; Notice of Consideration of Issuance of License; and Notice of Hearing and Commission Order, 69 Fed. 5873 (Feb. 6, 2004); GE-Hitachi Global Laser Enrichment LLC; (GLE Commercial Facility); Notice of Receipt of Application for License; Notice of Consideration of Issuance of License; Notice of Hearing and Commission Order, 75 Fed. Reg. 1819 (Jan. 13, 2010).

Evaluation of the Applicability of 10 CFR Part 52 Content of Application Regulatory Requirements to non-Light Water Reactors Review and justifications for regulations found to be generically not applicable for non-light water reactors Prepared by the Nuclear Energy Institute October 2020

© NEI 2020. All rights reserved. nei.org

October 2020 Acknowledgements This document was developed by the Nuclear Energy Institute. NEI acknowledges and appreciates the contributions of NEI members and other organizations in providing input, reviewing and commenting on the document including

  • Marty ONeill, NEI
  • Alexandra Renner, Oklo
  • The NEI Advanced Reactor Regulatory Task Force NEI Project Lead: Kati Austgen Notice Neither NEI, nor any of its employees, members, supporting organizations, contractors, or consultants make any warranty, expressed or implied, or assume any legal responsibility for the accuracy or completeness of, or assume any liability for damages resulting from any use of, any information apparatus, methods, or process disclosed in this report or that such may not infringe privately owned rights.

© NEI 2020. All rights reserved. nei.org

October 2020 Table of Contents 1 Introduction ..................................................................................................................................... 6 2 Applicability of Regulations for Non-Light Water Reactors ............................................................. 7 2.1 Disposition of applicability of regulations for contents of the FSAR .................................. 7 2.2 Format of this Paper ........................................................................................................... 8 2.3 Legal Justification ................................................................................................................ 9 3 General design criteria - 10 CFR 52.79(a)(4) ................................................................................. 10 3.1 Purpose ............................................................................................................................. 10 3.2 Technical Justification ....................................................................................................... 10 3.3 Regulatory Justification..................................................................................................... 10 4 ECCS and RCS vents - 10 CFR 52.79(a)(5) ...................................................................................... 11 4.1 Purpose ............................................................................................................................. 11 4.2 Technical Justification ....................................................................................................... 12 4.2.1 Background .......................................................................................................... 12 4.2.2 ECCS Cooling Performance .................................................................................. 12 4.2.3 Need for high-point vents following postulated loss of coolant accidents ......... 12 4.3 Regulatory Justification..................................................................................................... 13 4.3.1 10 CFR 50.46 ........................................................................................................ 13 4.3.2 10 CFR 50.46a ...................................................................................................... 13 5 Fire protection General Design Criterion - 10 CFR 52.79(a)(6) ..................................................... 14 5.1 Purpose ............................................................................................................................. 14 5.2 Technical Justification ....................................................................................................... 14 5.3 Regulatory Justification..................................................................................................... 15 6 Pressurized thermal shock - 10 CFR 52.79(a)(7) ........................................................................... 15 6.1 Purpose ............................................................................................................................. 15 6.2 Technical Justification ....................................................................................................... 15 6.3 Regulatory Justification..................................................................................................... 15 6.3.1 10 CFR 50.60 ........................................................................................................ 15 6.3.2 10 CFR 50.61 ........................................................................................................ 16 7 Station blackout - 10 CFR 52.79(a)(9) ........................................................................................... 16 7.1 Purpose ............................................................................................................................. 16 7.2 Technical Justification ....................................................................................................... 16 7.3 Regulatory Justification..................................................................................................... 17

© NEI 2020. All rights reserved. nei.org

October 2020 8 Codes and standards - 10 CFR 52.79(a)(11) .................................................................................. 17 8.1 Purpose ............................................................................................................................. 17 8.2 Technical Justification ....................................................................................................... 17 8.3 Regulatory Justification..................................................................................................... 18 8.3.1 LWR-specific 10 CFR 50.55a requirements .......................................................... 19 8.3.1.1 ASME BPV Code ...................................................................................... 20 8.3.1.2 ASME OM Code....................................................................................... 21 8.3.2 Outdated 10 CFR 50.55a requirements ............................................................... 21 9 Primary containment leakage rate testing program - 10 CFR 52.79(a)(12) .................................. 22 9.1 Purpose ............................................................................................................................. 22 9.2 Technical Justification ....................................................................................................... 22 9.3 Regulatory Justification..................................................................................................... 23 10 Reactor vessel material surveillance program - 10 CFR 52.79(a)(13) ........................................... 23 10.1 Purpose ............................................................................................................................. 23 10.2 Technical Justification ....................................................................................................... 23 10.3 Regulatory Justification..................................................................................................... 24 11 Effluent monitoring and sampling - 10 CFR 52.79(a)(16).............................................................. 24 11.1 Purpose ............................................................................................................................. 24 11.2 Technical Justification ....................................................................................................... 25 11.3 Regulatory Justification..................................................................................................... 25 12 Three Mile Island requirements - 10 CFR 52.79(a)(17) ................................................................. 25 12.1 Purpose ............................................................................................................................. 25 12.2 Technical Justification ....................................................................................................... 26 12.3 Regulatory Justification..................................................................................................... 26 13 Severe accidents - 10 CFR 52.79(a)(38) ......................................................................................... 27 13.1 Purpose ............................................................................................................................. 27 13.2 Technical Justification ....................................................................................................... 27 13.3 Regulatory Justification..................................................................................................... 28 14 Standard Review Plan evaluation - 10 CFR 52.79(a)(41) ............................................................... 28 14.1 Purpose ............................................................................................................................. 28 14.2 Technical Justification ....................................................................................................... 28 14.3 Regulatory Justification..................................................................................................... 29 15 Anticipated transients without scram - 10 CFR 52.79(a)(42) ........................................................ 29

© NEI 2020. All rights reserved. nei.org

October 2020 15.1 Purpose ............................................................................................................................. 29 15.2 Technical Justification ....................................................................................................... 29 15.3 Regulatory Justification..................................................................................................... 30 16 References ..................................................................................................................................... 31

© NEI 2020. All rights reserved. nei.org

October 2020 1 INTRODUCTION Section 50.1, General provisions, to Title 10 of the Code of Federal Regulations (10 CFR), states, in part, The regulations in this part are promulgated by the Nuclear Regulatory Commission pursuant to the Atomic Energy Act of 1954 (AEA), as amended (68 Stat. 919), and Title II of the Energy Reorganization Act of 1974 (88 Stat. 1242), to provide for the licensing of production and utilization facilities. Further, the U.S. Nuclear Regulatory Commission (NRC) mission states the following:

The NRC licenses and regulates the Nation's civilian use of radioactive materials to provide reasonable assurance of adequate protection of public health and safety and to promote the common defense and security and to protect the environment.

The NRC generally implements the relevant portions of the Atomic Energy Act (AEA), as codified in U.S.

Code (USC), through regulations, although the NRC retains the authority to establish the level of protection that it considers adequate and reasonable.

Regulations from the CFR for nuclear power plants generally have two characteristics: (1) they contain assumptions about the facility, and (2) they evoke that adequate protection is assured, in part, through compliance.

The delineation between regulations that apply and those that do not is nested in the former - the assumptions in each regulation. Many regulations in 10 CFR Part 50 and 10 CFR Part 52 were tailored to large light water reactors (LWRs) and make assumptions about the technology in the language of each requirement. Many of the assumptions that these regulations make can be applied to other reactor technologies, besides large LWRs. However, some regulations make assumptions that are specific to either large reactors or reactors that are water-cooled. These regulations do not apply, that is their underlying purpose does not apply and they are not technically relevant, to reactors that are not large LWRs. Identification of these regulations should facilitate more streamlined non-light water reactor (non-LWR) applications and more efficient NRC reviews by focusing the application and the NRC staffs review thereof on the information that is directly relevant to the NRCs safety findings.

For the regulations that do apply, the premise is that if compliance is demonstrated, the intent of the regulation is met, and adequate protection is assured. However, because some regulations are overly prescriptive or are technology-specific, this logic does not hold for all regulations for all reactors. If a non-LWR meets the underlying intent of applicable regulations without prescriptive compliance, the process to demonstrate this conclusion should be streamlined and consistent between Part 50 and Part 52. However, the question of how to optimize exemptions or otherwise streamline the documentation of meeting the underlying intent of applicable regulations is not the topic of this paper.

This document presents an evaluation of the applicability of 10 CFR Part 52 content of application regulatory requirements to non-LWRs. Specifically, the content of application requirements in 10 CFR 52.79 and associated Part 50 references have been considered. Thus, it is not intended to be an exhaustive review of all regulatory requirements.

© NEI 2020. All rights reserved. nei.org 6

October 2020 2 APPLICABILITY OF REGULATIONS FOR NON-LIGHT WATER REACTORS 2.1 Disposition of applicability of regulations for contents of the FSAR Applicants for a combined license are required by 10 CFR 52.79, Contents of applications; technical information in final safety analysis report, to submit a final safety analysis report (FSAR). Section 52.79 to 10 CFR contains 47 specific requirements for information that must be submitted. Most of these requirements apply to non-LWR designs, and compliance with them should be discussed in the FSAR.

The remainder of the 10 CFR 52.79 requirements do not apply to non-LWRs and are discussed in this paper, with justifications. The regulations that do not apply make assumptions about design features that are not present in non-LWRs. Since many 10 CFR 52.79 requirements point back to 10 CFR Part 50, the relevant section from 10 CFR Part 50 is discussed, where appropriate.

Table 2-1 summarizes the disposition of the 10 CFR 52.79 requirements with their generic applicability to non-LWRs. We recognize that the applicability of some regulations to non-LWRs may depend on the specifics of a reactor design. In such cases, the development and use of performance-based entry conditions may be an acceptable solution.

Table 2-1: Applicability of 10 CFR 52.79 to non-light water reactors Section Short description Applicable 52.79(a)(1) Site envelope and boundary Yes 52.79(a)(2) Design and analysis of SSCs Yes 52.79(a)(3) Radioactive materials produced in operation Yes 52.79(a)(4) Principal design criteria Partial 52.79(a)(5) Transient analysis Partial 52.79(a)(6) Fire protection Partial 52.79(a)(7) Pressurized thermal shock No 52.79(a)(8) Combustible gas control Yes 52.79(a)(9) Station blackout No 52.79(a)(10) Environmental qualification of electric equipment Yes 52.79(a)(11) Codes and standards No 52.79(a)(12) Primary containment leakage rate testing program No 52.79(a)(13) Reactor vessel material surveillance program No 52.79(a)(14) Operator training program Yes 52.79(a)(15) Maintenance rule Yes 52.79(a)(16) Effluent monitoring and sampling No 52.79(a)(17) Three Mile Island requirements No 52.79(a)(18) Risk-informed treatment of SSCs Yes 52.79(a)(19) Earthquake criteria Yes 52.79(a)(20) Unresolved and generic safety issues Yes 52.79(a)(21) Emergency planning Yes 52.79(a)(22) Emergency planning with state and local governments Yes

© NEI 2020. All rights reserved. nei.org 7

October 2020 Section Short description Applicable 52.79(a)(23) Reserved -

52.79(a)(24) Prototype operational conditions Yes 52.79(a)(25) Quality Assurance Program - design Yes 52.79(a)(26) Organizational structure for operations Yes 52.79(a)(27) Quality Assurance Program - operation Yes 52.79(a)(28) Preoperational testing and initial operations Yes 52.79(a)(29) Operational plans Yes 52.79(a)(30) Technical Specifications Yes 52.79(a)(31) Multi-unit sites Yes 52.79(a)(32) Technical qualifications of the applicant Yes 52.79(a)(33) Training Program description Yes 52.79(a)(34) Operator requalification Yes 52.79(a)(35) Physical security plans Yes 52.79(a)(36) Safeguards and other security plans Yes 52.79(a)(37) Incorporation of operational insights Yes 52.79(a)(38) Severe accidents No 52.79(a)(39) Radiation Protection Program description Yes 52.79(a)(40) Fire Protection Program description Yes 52.79(a)(41) Standard Review Plan evaluation No 52.79(a)(42) Anticipated transients without scram No 52.79(a)(43) Criticality accidents Yes 52.79(a)(44) Fitness-for-Duty Program description Yes 52.79(a)(45) Minimization of contamination Yes 52.79(a)(46) Probabilistic risk assessment summary Yes 52.79(a)(47) Aircraft impact assessment Yes 2.2 Format of this Paper The regulations identified in Table 2-1 as not applicable, i.e., the response in the Applicable column is No, or Partial, are discussed in this paper in the context of generic non-applicability to non-LWRs.

Specific regulations discussed in this paper are shown in Table 2-2. An additional column is added to indicate the NRC staff position on the generic non-applicability to non-LWRs of each regulation.

Table 2-2: Regulations generically not applicable to non-light water reactors Section Short description Non-applicability description NRC staff position1 52.79(a)(4) Principal design criteria General design criteria In agreement 52.79(a)(5) Transient analysis ECCS and RCS vents In agreement Fire protection General Design 52.79(a)(6) Fire protection Criterion In agreement

© NEI 2020. All rights reserved. nei.org 8

October 2020 52.79(a)(7) Pressurized thermal shock Pressurized thermal shock In agreement 52.79(a)(9) Station blackout Station blackout In agreement 52.79(a)(11) Codes and standards Codes and standards In agreement Primary containment leakage Primary containment leakage 52.79(a)(12) rate testing program rate testing program In agreement Reactor vessel material Reactor vessel material 52.79(a)(13) surveillance program surveillance program In agreement Effluent monitoring and Effluent monitoring and 52.79(a)(16) sampling sampling Partial agreement 52.79(a)(17) Three Mile Island requirements Three Mile Island requirements In agreement 52.79(a)(38) Severe accidents Severe accidents In agreement 52.79(a)(41) Standard Review Plan evaluation Standard Review Plan evaluation In agreement Anticipated transients without Anticipated transients without 52.79(a)(42) scram scram In agreement 1

Per the NRC staff white paper, Non-light water review strategy. Sep. 2019.

This paper discusses each of the regulations in Table 2-2. Each non-applicability discussion has the same format and includes the following items:

  • Purpose
  • Technical justification
  • Regulatory justification The purpose section describes the portion(s) of the regulation that does not apply generically to non-LWRs. Strikeout text is used to denote this non-applicability. Certain regulations do not apply in full, whereas others only partially do not apply. The technical justification section describes the technical reason for why the particular regulation does not apply and suggests entry criteria where useful in identifying non-LWR design characteristics. The regulatory justification provides information such as regulatory precedent that shows that the intent of the regulation was for light water reactors.

2.3 Legal Justification Additionally, the following legal justification shows legal compliance with the relevant portions of the AEA, as codified in U.S. Code (USC). The regulations identified as not applicable in Table 2-2, above, do not preclude compliance with applicable law or the Commissions required statutory findings. AEA Section 182 (License Applications), 42 USC 2232, requires that applicants provide such technical information, including the specific characteristics of the facility, as the Commission may, by rule or regulation, deem necessary to enable it to find that operation of the facility will be in accordance with the common defense and security and provide adequate protection of the public health and safety. AEA Section 185.b, 42 USC 2235(b), Construction Permits and Operating Licenses, requires, in pertinent part, that an application contain sufficient information to support the issuance of a combined license.

Given that the requirements identified in the corresponding regulations listed in Table 2-2 either do not

© NEI 2020. All rights reserved. nei.org 9

October 2020 directly apply to non-LWRs or are specific to the characteristics of, or risk of events in, LWRs, compliance with those identified as not applicable is not necessary to support the NRCs required statutory findings under the AEA for non-LWRs.

3 GENERAL DESIGN CRITERIA - 10 CFR 52.79(A)(4) 3.1 Purpose This section explains why 10 CFR 52.79(a)(4) does not fully apply to non-LWRs. Specifically, the part of the requirement that does not apply is 10 CFR 52.79(a)(4)(i), which points to Appendix A, General design criteria for nuclear power plants, to Part 50 of 10 CFR. The specific non-applicability is shown in the below quoted text, using strike out:

(10)The principal design criteria for the facility. Appendix A to part 50 of this chapter, General Design Criteria for Nuclear Power Plants, establishes minimum requirements for the principal design criteria for water-cooled nuclear power plants similar in design and location to plants for which construction permits have previously been issued by the Commission and provides guidance to applicants in establishing principal design criteria for other types of nuclear power units; (ii) The design bases and the relation of the design bases to the principal design criteria; (iii) Information relative to materials of construction, arrangement, and dimensions, sufficient to provide reasonable assurance that the design will conform to the design bases with adequate margin for safety.

3.2 Technical Justification The portion of 10 CFR 52.79(a)(4) that does not apply is only with regard to the reference to 10 CFR Part 50, Appendix A. The remainder of 10 CFR 52.79(a)(4) applies and should be covered in the FSAR. Specifically, the FSAR should propose principal design criteria, discuss the design bases and the relation of the design bases to the principal design criteria, and provide information relative to material of construction arrangement, and dimensions, sufficient to provide reasonable assurance that the design will conform to the design bases with adequate margin for safety.

3.3 Regulatory Justification Principal design criteria are required for each facility licensed under 10 CFR Part 52. Since 10 CFR 52.79 was developed after LWRs were already operating, many of the requirements for contents of the safety analysis report were informed by the operating LWR fleet. Specifically, Appendix A to 10 CFR Part 50 sets forth the minimum requirements for water-cooled reactor principal design criteria, referred to as the General Design Criteria (GDC), and notes that the GDC may provide guidance in establishing the PDC for other types of nuclear power units.

© NEI 2020. All rights reserved. nei.org 10

October 2020 These points are reinforced by Regulatory Guide (RG) 1.232, Guidance for developing principal design criteria for non-light-water reactors, Revision 0, which notes:

A key part of the regulatory requirements is in the general design criteria (GDC) in Appendix A to 10 CFR Part 50. These high-level GDC requirements support the design of the current nuclear power plants and are addressed in 10 CFR 50.34, Contents of Applications; Technical Information. Because the current GDC are based on LWR technology, the NRC developed the non-LWR design criteria, included as appendices to this RG, to provide guidance for developing PDC for non-LWR technology.

Although non-LWRs licensed under 10 CFR Part 50 and 10 CFR Part 52 must propose principal design criteria, they do not need to comply with the GDC described in 10 CFR Part 50, Appendix A. As stated by the NRC staff in RG 1.232:

Together, these requirements recognize that different requirements may need to be adapted for non-LWR designs and that the GDC in 10 CFR 50 Appendix A are not regulatory requirements for non LWR designs but provide guidance in establishing the PDC for non-LWR designs.

RG 1.232 is a guidance document and therefore imposes no regulatory requirements itself. Thus, while the RG offers design criteria that might be useful for non-LWR technologies, its use is voluntary. This fact is reflected in the Purpose of Regulatory Guides section of RG 1.232:

The NRC issues RGs to describe to the public methods that the staff considers acceptable for use in implementing specific parts of the agencys regulations, to explain techniques that the staff uses in evaluating specific problems or postulated events, and to provide guidance to applicants.

Regulatory guides are not substitutes for regulations and compliance with them is not required.

Therefore, Appendix A to 10 CFR Part 50 does not strictly apply to non-LWRs or otherwise impose binding legal requirements on non-LWR combined license applicants. NRC staff also recently acknowledged that this regulation is based on LWR technology, and that the principal design criteria provided by the non-LWR designer or applicant establish the necessary design, fabrication, construction, testing, and performance of safety-significant structures, systems, and components (SSCs).[1] Instead of utilizing Appendix A to 10 CFR Part 50, principal design criteria should be proposed in the FSAR, as per 10 CFR 52.79(a)(4).

4 ECCS AND RCS VENTS - 10 CFR 52.79(A)(5) 4.1 Purpose This section explains why 10 CFR 52.79(a)(5) does not apply, in part, to non-light water reactors. The parts of the regulation that do not apply are the analysis and evaluation of emergency core cooling system (ECCS) cooling performance and the need for high-point vents following postulated loss of coolant accidents, to be performed in accordance with the requirements of 10 CFR 50.46, Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors, and 10 CFR 50.46a, Acceptance criteria for reactor coolant system venting systems. The specific non-applicability is shown in the below-quoted text, using strike out:

© NEI 2020. All rights reserved. nei.org 11

October 2020 An analysis and evaluation of the design and performance of structures, systems, and components with the objective of assessing the risk to public health and safety resulting from operation of the facility and including determination of the margins of safety during normal operations and transient conditions anticipated during the life of the facility, and the adequacy of structures, systems, and components provided for the prevention of accidents and the mitigation of the consequences of accidents. Analysis and evaluation of ECCS cooling performance and the need for high-point vents following postulated loss-of-coolant accidents shall be performed in accordance with the requirements of §§ 50.46 and 50.46a of this chapter; 4.2 Technical Justification 4.2.1 Background 10 CFR 52.79(a)(5) requires an analysis of the ECCS cooling performance following postulated loss of coolant accidents, as well as an evaluation of whether high point vents are required. Since 10 CFR 52.79 was developed with LWRs in mind, it explicitly references systems that are incorporated by LWRs, such as the ECCS. The ECCS is used by LWRs to provide core decay heat removal capability in the event of a failure of the reactor coolant system. The successful operation of the decay heat removal capability of the ECCS is important for ensuring that LWRs do not exceed fuel safety limits following a loss of coolant accident.

4.2.2 ECCS Cooling Performance Non-LWRs do not possess an ECCS. A loss of coolant accident is defined in 10 CFR 50.46(c)(1) in the following way:

Loss-of-coolant accidents (LOCA's) are hypothetical accidents that would result from the loss of reactor coolant, at a rate in excess of the capability of the reactor coolant makeup system, from breaks in pipes in the reactor coolant pressure boundary up to and including a break equivalent in size to the double-ended rupture of the largest pipe in the reactor coolant system.

A LOCA is a specific major accident for LWRs and the ECCS is a specific LWR system. LOCAs might not be possible or not be technically relevant for non-LWRs; subsequently, ECCS likely does not exist in non-LWRs or has no equivalent. The remainder of the applicable regulation in 10 CFR 52.79(a)(5) already requires the safety analysis during normal operations and transient conditions, which is broad enough to scope the relevant challenging accidents, and should be documented in the FSAR. The specific requirement in 10 CFR 52.79(a)(5) relates to an LWR specific accident and system. Therefore, the requirement to analyze the performance of an ECCS following a loss of coolant accident is not technically relevant for non-LWRs and those accidents that are technically relevant are already scoped by the applicable portion of 10 CFR 52.79(a)(5).

4.2.3 Need for high-point vents following postulated loss of coolant accidents High point vents are required for LWRs for the reactor coolant system, the reactor vessel head, and for other systems required to maintain adequate core cooling if the accumulation of noncondensible gases could cause the loss of function of these systems. 10 CFR 52.79(a)(5) requires an analysis to determine whether, following a LOCA, high point vents are needed as part of the system design to eliminate the challenge posed by a possible accumulation of these noncondensible gases, in order to ensure that adequate core cooling can be maintained.

© NEI 2020. All rights reserved. nei.org 12

October 2020 As discussed in Section 4.2.2, the requirement to evaluate LOCAs is specific to LWRs. LOCAs might not be possible or not be technically relevant for non-LWRs, non-LWRs might not have a reactor coolant system or a reactor vessel head, and non-LWRs might not need to protect against the accumulation of noncondensible gases because the noncondensible gasses or the systems that need to be protected might not exist. The remainder of the applicable regulation in 10 CFR 52.79(a)(5) already requires a safety analysis during normal operations and transient conditions, which is broad enough to scope the relevant challenging accidents, and should be documented in the FSAR. Therefore, the requirement to analyze the need for high-point vents following postulated LOCAs is not technically relevant for non-LWRs and those accidents that are technically relevant are already scoped by the applicable portion of 10 CFR 52.79(a)(5).

4.3 Regulatory Justification The relevant portion of 10 CFR 52.79(a)(5) for this non-applicability is the following text, Analysis and evaluation of ECCS cooling performance and the need for high-point vents following postulated loss-of-coolant accidents shall be performed in accordance with the requirements of §§ 50.46 and 50.46a of this chapter. Section 50.46 and Section 50.46a to 10 CFR are further discussed in this section.

4.3.1 10 CFR 50.46 10 CFR 50.46 specifically applies to boiling and pressurized water reactors, as stated in 10 CFR 50.46(a)(1)(i):

Each boiling or pressurized light-water nuclear power reactor fueled with uranium oxide pellets within cylindrical zircaloy or ZIRLO cladding must be provided with an emergency core cooling system (ECCS) that must be designed so that its calculated cooling performance following postulated loss-of-coolant accidents conforms to the criteria set forth in paragraph (b) of this section.

Non-LWRs are not boiling or pressurized water reactors. The NRC staff has recently acknowledged that this regulation does not apply to non-LWRs, stating, in part:

However, the second sentence of each citation states that an analysis and evaluation of the ECCS cooling performance shall be provided in accordance with 10 CFR 50.46, which is not applicable to non-LWRs.[1]

Therefore, the design features that are assumed to be present by this regulation do not exist in non-LWRs, and this regulation is not applicable.

4.3.2 10 CFR 50.46a 10 CFR 50.46a has the following language in terms of applicability of the regulation:

Each nuclear power reactor must be provided with high point vents for the reactor coolant system, for the reactor vessel head, and for other systems required to maintain adequate core cooling if the accumulation of noncondensible gases would cause the loss of function of these systems. High point vents are not required for the tubes in U-tube steam generators.

© NEI 2020. All rights reserved. nei.org 13

October 2020 The need for this regulation was established in 1981 as an amendment to 10 CFR 50.44 because this requirement is more closely related to the regulation for ECCS in 10 CFR 50.46. The need for high point venting was specifically recognized as important to safety in reactor systems that can use natural circulation of the reactor coolant. It was also recognized as important in reactor systems that utilize an ECCS, in order to assure that any noncondensibles could be vented before they cause operational concerns with the ECCS pumps. As such, this requirement strives to mitigate the core cooling function and does not apply to aggravation that will be inevitably placed on the containment. 1 Specifically, the original requirement in 10 CFR 50.44 and the subsequent requirement in 10 CFR 50.46a seek to assure the safety of plants that rely on natural circulation and ECCS for cooling, as stated by the NRC:

This process is regarded as an important safety feature in accident sequences that credit natural circulation of the reactor coolant system. In other sequences, the pockets of noncondensible gases may interfere with pump operation. The high point vents could be instrumental for terminating a core damage accident if ECCS operation is restored. Under these circumstances, venting noncondensible gases from the vessel allows emergency core cooling flow to reach the damaged reactor core and thus, prevents further accident progression. 2 The assumption that non-LWRs have an ECCS, a reactor coolant system, a reactor vessel head, or systems required to maintain adequate core cooling, considering the accumulation of noncondensible gases, is too prescriptive and not technically relevant. The NRC staff also recently acknowledged that this regulation is based on LWR technology and is likely to not apply to non-LWRs.[1] Therefore, because these design features do not exist in non-LWRs, this regulation is not applicable.

5 FIRE PROTECTION GENERAL DESIGN CRITERION - 10 CFR 52.79(A)(6) 5.1 Purpose This section explains why 10 CFR 52.79(a)(6) does not apply, in part, to non-LWRs. Specifically, 10 CFR 52.79(a)(6) does not apply to non-LWRs insofar as it requires compliance with GDC 3 of Appendix A to 10 CFR Part 50, with regard to the fire protection plan. The specific non-applicability is shown in the below quoted text, using strike out:

A description and analysis of the fire protection design features for the reactor necessary to comply with 10 CFR part 50, appendix A, GDC 3, and § 50.48 of this chapter.

5.2 Technical Justification The portion of 10 CFR 52.79(a)(6) that does not apply is only with regard to the reference to 10 CFR Part 50, Appendix A, GDC 3. The remainder of 10 CFR 52.79(a)(6) applies to non-LWRs and should be covered in the FSAR.

1 68 FR 54129, September 16, 2003 2

68 FR 54133, September 16, 2003

© NEI 2020. All rights reserved. nei.org 14

October 2020 5.3 Regulatory Justification As discussed in Section 3.3, the GDC do not apply to non-LWRs because they are based on water-cooled reactor technology. Therefore, GDC 3 of Appendix A to 10 CFR does not apply to non-LWRs as the entire set of the GDC do not apply to non-LWRs.

6 PRESSURIZED THERMAL SHOCK - 10 CFR 52.79(A)(7) 6.1 Purpose This section explains why 10 CFR 52.79(a)(7) does not apply to non-LWRs. Specifically, no portion of 10 CFR 52.79(a)(7) applies to non-LWRs, as shown using strike out in the below quoted text:

A description of protection provided against pressurized thermal shock events, including projected values of the reference temperature for the reactor vessel beltline materials as defined in 10 CFR 50.60 and 50.61(b)(1) and (b)(2) of this chapter; 6.2 Technical Justification Pressurized thermal shock is an event or transient in pressurized water reactors causing severe overcooling (thermal shock) concurrent with or followed by significant pressure in the reactor vessel.

This kind of event challenges the integrity of the reactor pressure vessel, especially in vessels that have experienced embrittlement from exposure to a high neutron fluence [2]. Because the reactor pressure vessel is a vital component in LWR designs, its integrity needs to be ensured.

Non-LWRs are neither LWRs, generally, nor pressurized water reactors, specifically. Pressurized thermal shock is an event historically identified particular to pressurized water reactors. Since non-LWRs will analyze and identify important events in different ways than historical events specific to LWRs, maintaining applicability of an event specifically important to a pressurized water reactor introduces inconsistencies for non-LWR regulation. Further, 10 CFR 52.79(a) already requires a thorough safety analysis of any design that is the subject of a combined license application.

6.3 Regulatory Justification 6.3.1 10 CFR 50.60 The requirements of 10 CFR 52.79(a)(7) point to 10 CFR 50.60, Acceptance criteria for fracture prevention measures for light water nuclear power reactors for normal operation, and 10 CFR 50.61, Fracture toughness requirements for protection against pressurized thermal shock events.

Specifically, 10 CFR 50.60(a) states the applicability of the regulation as follows:

Except as provided in paragraph (b) of this section, all light-water nuclear power reactors, other than reactor facilities for which the certifications required under § 50.82(a)(1) have been submitted, must meet the fracture toughness and material surveillance program requirements for the reactor coolant pressure boundary set forth in appendices G and H to this part.

© NEI 2020. All rights reserved. nei.org 15

October 2020 Non-LWRs do not have the design features assumed by 10 CFR 50.60, specifically as they are not light-water nuclear power reactors. The NRC staff has recently acknowledged that this regulation does not apply to non-LWRs.[1] Therefore, the requirements of 10 CFR 50.60 do not apply.

6.3.2 10 CFR 50.61 Additionally, 10 CFR 50.61(b)(1) describes the applicability of this regulation as follows, in part:

For each pressurized water nuclear power reactor for which an operating license has been issued under this part or a combined license issued under Part 52 of this chapter, other than a nuclear power reactor facility for which the certification required under § 50.82(a)(1) has been submitted, the licensee shall have projected values of RTPTS or RTMAX-X, accepted by the NRC, for each reactor vessel beltline material Because non-LWRs are not pressurized water nuclear power reactors, the design features assumed by 10 CFR 50.61 do not exist. The NRC staff has recently acknowledged that this regulation does not apply to non-LWRs.[1] Therefore, the requirements of 10 CFR 50.61 do not apply.

7 STATION BLACKOUT - 10 CFR 52.79(A)(9) 7.1 Purpose This section explains why 10 CFR 52.79(a)(9) does not apply to non-LWRs. Specifically, no portion of 10 CFR 52.79(a)(9) applies to non-LWRs, as shown using strike out in the below quoted text:

The coping analyses, and any design features necessary to address station blackout, as described in § 50.63 of this chapter; 7.2 Technical Justification 10 CFR 50.63, Loss of all alternating current power, requires LWRs to submit analyses, plans, procedures, and other information related to the ability of the plant to cope and recover from a station blackout. Currently operating LWRs in the U.S. are large and subsequently produce large amounts of decay heat following reactor shutdown. Because of this large amount of decay heat, these LWRs have many safety-related systems, especially active core cooling systems, that rely on alternating current (AC) electrical power to operate. The AC electrical power must be available after reactor shutdown to keep these safety-related systems operational in order to ensure that LWR safety limits are maintained.

Non-LWRs generally are designed such that they do not rely on the use of offsite AC power or emergency onsite power to shut down the reactor, ensure that the core is cooled, or ensure appropriate containment integrity is maintained in the event of an indefinite duration station blackout. Therefore, station blackout is not challenging for most non-LWRs because the reactor has been designed with this LWR experience in mind. Other regulations in 10 CFR 52.79(a) already require a thorough safety analysis.

If a station blackout event were relevant to the design, it would be scoped under other portions of 10 CFR 52.79(a). Therefore, station blackout is not technically relevant for non-LWRs and 10 CFR 50.63 is not applicable.

© NEI 2020. All rights reserved. nei.org 16

October 2020 7.3 Regulatory Justification The requirements of 10 CFR 52.79(a)(9) point to 10 CFR 50.63. Specifically, 10 CFR 50.63(a)(1) outlines the applicability of this requirement, as follows:

Each light-water-cooled nuclear power plant licensed to operate under this part, each light-water-cooled nuclear power plant licensed under subpart C of 10 CFR part 52 after the Commission makes the finding under § 52.103(g) of this chapter, and each design for a light-water-cooled nuclear power plant approved under a standard design approval, standard design certification, and manufacturing license under part 52 of this chapter must be able to withstand for a specified duration and recover from a station blackout as defined in § 50.2.

The purpose of this rule was to ensure that LWRs can withstand a total loss of AC electric power (i.e.,

station blackout) for a specified duration and can maintain reactor core cooling during that period. The assumption in this regulation is that AC electric power is needed for both essential and nonessential service and is provided by offsite power. These systems are assumed to provide power for various safety functions, including decay heat removal and containment heat removal. 3 Non-LWRs are not light-water-cooled nuclear power plants and generally do not require AC electric power to maintain reactor core cooling. The NRC staff has recently acknowledged that this regulation does not apply to non-LWRs.[1] Additionally, other regulations in 10 CFR 52.79(a) already require a thorough safety analysis. If a station blackout event were relevant to the design, it would be scoped under other portions of 10 CFR 52.79(a). Therefore, the design features that are assumed to be present by this regulation do not exist in non-LWRs, and this regulation is not applicable.

8 CODES AND STANDARDS - 10 CFR 52.79(A)(11) 8.1 Purpose This section explains why 10 CFR 52.79(a)(11) does not apply to non-LWRs. Specifically, effectively no portion of 10 CFR 52.79(a)(11) applies to non-LWRs, as shown using strike out in the below quoted text:

A description of the program(s), and their implementation, necessary to ensure that the systems and components meet the requirements of the ASME Boiler and Pressure Vessel Code and the ASME Code for Operation and Maintenance of Nuclear Power Plants in accordance with 50.55a of this chapter.

8.2 Technical Justification 10 CFR 50.55a, Codes and standards, requires compliance with certain codes and standards from the American Society of Mechanical Engineers (ASME) and the Institute of Electrical and Electronics Engineers (IEEE). Specifically, 10 CFR 50.55a(a) incorporates codes and standards from ASME and IEEE by reference, and the remainder of Section 50.55a specifies when the incorporated codes and standards must be followed. In the September 2020 NRC Staff Draft White Paper, Analysis of Applicability of NRC Regulations for Non-Light Water Reactors, NRC staff acknowledge that 10 CFR 50.55a(a) does not itself impose requirements, and thus the basis for calling it applicable to non-LWRs is unclear. Further, 3

53 FR 23203, June 21, 1988

© NEI 2020. All rights reserved. nei.org 17

October 2020 continuing to guide individual applicants to assess the list of standards is a missed opportunity for regulatory efficiency.

Sections 50.55a(b)-(g) of 10 CFR require that certain components and systems meet specific ASME codes. These sections refer to (b) the ASME Boiler and Pressure Vessel (ASME BPV) Code and the ASME Operation and Maintenance (ASME OM) Code, (c)-(e) Quality Groups, (f) preservice and inservice testing, and (g) preservice and inservice inspection. Each of these requirements are specifically for boiling and pressurized water-cooled nuclear reactors. Examples of differences in technologies between LWRs (i.e., boiling and pressurized water-cooled nuclear reactors) and non-LWRs include operating temperatures and operating pressures. Most non-LWRs are designed to operate at significantly different conditions than those for which these code requirements were developed to address, including temperature, materials, pressure, and other characteristics. Further, certain ASME Codes that are incorporated by reference by the NRC specifically state that they are not applicable to non-LWRs. In contrast, non-LWRs might be able to use other portions of ASME Codes, which are not for pressure vessels, or other industry vessel standards altogether, such as ASTM standards. Therefore, these portions of 10 CFR 50.55a(b) through (g) are not technically relevant to non-light water reactors.

10 CFR 50.55a(h)(2) is dated and thus not applicable to non-LWR applications. Conversely, 10 CFR 50.55a(h)(3) does apply for safety related instrumentation and control in non-LWRs.

10 CFR 50.55a(z) provides for alternatives to 10 CFR 50.55a and is therefore outside of the scope of this document.

8.3 Regulatory Justification Section 50.55a of 10 CFR is broken up into several paragraphs, which are further grouped for purposes of discussion in this document and shown in Table 8-1. There are five groups discussed: (1) LWR-specific, (2) Outdated, (3) Reserved, (4) Quality, and (5) Safety-related instrumentation and control (I&C). 10 CFR 50.55a(z) is ungrouped because this paragraph provides for alternatives to 10 CFR 50.55a and is therefore outside of the scope of this document. This discussion focuses on the first and second group, LWR-specific and Outdated, respectively.

Table 8-1: 10 CFR 50.55a groups 10 CFR 50.55a paragraph Group (a) Documents approved for incorporation by reference (1) American Society of Mechanical Engineers (ASME) LWR-specific (i) ASME Boiler and Pressure Vessel Code,Section III LWR-specific (ii) ASME Boiler and Pressure Vessel Code,Section XI LWR-specific (iii) ASME Code Cases: Nuclear Components LWR-specific (iv) ASME Operation and Maintenance Code LWR-specific (v) ASME Quality Assurance Requirements Quality (2) Institute of Electrical and Electronics Engineers (IEEE)

(i) IEEE standard 279-1968 Outdated (ii) IEEE standard 279-1971 Outdated (iii) IEEE standard 603-1991 Safety-related I&C

© NEI 2020. All rights reserved. nei.org 18

October 2020 (iv) IEEE standard 603-1991, correction sheet Safety-related I&C (3) U.S. Nuclear Regulatory Commission (NRC) Public Document Room (i) NRC Regulatory Guide 1.84, Revision 36 LWR-specific (ii) NRC Regulatory Guide 1.147, Revision 17 LWR-specific (iii) NRC Regulatory Guide 1.192, Revision 1 LWR-specific (b) Use and conditions on the use of standards (1) Conditions on ASME BPV Code Section III LWR-specific (2) Conditions on ASME BPV Code,Section XI LWR-specific (3) Conditions on ASME OM Code LWR-specific (4) Conditions on Design, Fabrication, and Materials Code Cases LWR-specific (5) Conditions on inservice inspection Code Cases LWR-specific (6) Conditions on ASME OM Code Cases LWR-specific (c) Reactor coolant pressure boundary LWR-specific (d) Quality Group B components LWR-specific (e) Quality Group C components LWR-specific (f) Preservice and inservice testing requirements LWR-specific (g) Preservice and inservice inspection requirements LWR-specific (h) Protection and safety systems (1) Reserved Reserved (2) Protection systems Outdated (3) Safety systems Safety-related I&C (i)-(y) Reserved Reserved (z) Alternatives to codes and standards requirements None 8.3.1 LWR-specific 10 CFR 50.55a requirements The paragraphs discussed under this section are 10 CFR 50.55a(a)(1)(i)-(a)(1)(iv), 10 CFR 50.55a(a)(3),

10 CFR 50.55a(b), 10 CFR 50.55a(c), 10 CFR 50.55a(d), 10 CFR 50.55a(e), 10 CFR 50.55a(f), and 10 CFR 50.55a(g).

Section 50.55a(a)(1)(i)-(a)(1)(iv) of 10 CFR refer to the following items, respectively:

  • ASME Code Cases: Nuclear Components(A) ASME BPV Code Case N-513-3 Mandatory Appendix I; ASME BPV Code Case N-513-3, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division 1, Mandatory Appendix I, Relations for F m, F b, and F for Through-Wall Flaws
  • ASME Operation and Maintenance Code

© NEI 2020. All rights reserved. nei.org 19

October 2020 10 CFR 50.55a(a)(3) refers to the following NRC RGs and respective restrictions:

  • RG 1.84, Revision 36, Design, Fabrication, and Materials Code Case Acceptability, ASME Section III, dated August 2014, with the requirements in paragraph (b)(4) of this section.
  • RG 1.147, Revision 17, Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1, dated August 2014, which lists ASME Code Cases that the NRC has approved in accordance with the requirements in paragraph (b)(5) of this section.
  • RG 1.192, Revision 1, Operation and Maintenance Code Case Acceptability, ASME OM Code, dated August 2014, which lists ASME Code Cases that the NRC has approved in accordance with the requirements in paragraph (b)(6) of this section.

10 CFR 50.55a(b) provides requirements on the use and conditions of the codes and RGs listed in 10 CFR 50.55a(a)(1)(i)-(a)(1)(iv) and 10 CFR 50.55a(a)(3), respectively. Therefore, 10 CFR 50.55a(b) is not discussed separately.

10 CFR 50.55a(c), 10 CFR 50.55a(d), 10 CFR 50.55a(e), 10 CFR 50.55a(f), and 10 CFR 50.55a(g) provide requirements on the use and conditions of the ASME BPV Code. Therefore, 10 CFR 50.55a(c),

10 CFR 50.55a(d), 10 CFR 50.55a(e), 10 CFR 50.55a(f), and 10 CFR 50.55a(g) are not discussed separately from the ASME BPV Code discussion in Section 8.3.1.1.

8.3.1.1 ASME BPV Code The NRC has incorporated by reference parts of the ASME BPV Code Section III in its regulations.

Specifically, the only portions of the ASME BPV Code Section III that are incorporated by reference are located in Division 1. The ASME Codes generally apply only to boiling and pressurized water-cooled reactors, as stated during the time the rule was created: 4 It has been generally recognized that, for boiling and pressurized water-cooled reactors, pressure vessels, piping, pumps, and valves which are part of the reactor coolant pressure boundary should, as a minimum, be designed, fabricated, inspected, and tested in accordance with the requirements of the applicable American Society of Mechanical Engineers (ASME) codes in effect at the time the equipment is purchased Further, the NRC underscored the importance of important to safety components in water-cooled reactor designs: 5 The Commission considers that a significant improvement in the level of quality in design, fabrication, and testing of systems and components important to safety of water-cooled reactors will be afforded by compliance with the requirements of more recent versions of the codes than those specified in the amendments, or portions thereof, and encourages such compliance whenever practicable, regardless of the date of purchase of equipment or the provisions of these amendments.

4 36 FR 11423, June 12, 1971 5

36 FR 11424, June 12, 1971

© NEI 2020. All rights reserved. nei.org 20

October 2020 The use of the ASME BPV Code is required by the regulations for LWRs. Further, many non-LWRs will operate at temperatures and with materials that might not be covered by those ASME Codes that are incorporated by reference into 10 CFR 50.55a. Because non-LWRs are not water-cooled designs, 10 CFR 50.55a(a)(1)(i)-(iii), 10 CFR 50.55a(a)(3)(i)-(ii), 10 CFR 50.55a(b)(1)-(2), 10 CFR 50.55a(b)(4)-(5),

and 10 CFR 50.55a(c)-(g) do not apply. The NRC staff has recently acknowledged that these regulations do not apply to non-LWRs.[1, 3] Therefore, because these design features do not exist in non-LWRs, this regulation is not applicable.

8.3.1.2 ASME OM Code The NRC has incorporated by reference parts of the ASME OM Code. As stated in RG 1.192, Revision 2, the ASME OM Code was developed in the context of rules for the IST and inservice examination of pumps, valves, and dynamic restraints:

In 1990, the ASME published the initial edition of the OM Code that provides rules for IST and inservice examination of pumps, valves, and dynamic restraints (snubbers). The OM Code was developed and is maintained by the ASME Committee on Operation and Maintenance of Nuclear Power Plants. The OM Code was developed in response to the ASME Board on Nuclear Codes and Standards directive that transferred responsibility for development and maintenance of rules for the IST and inservice examination of pumps, valves, and dynamic restraints (snubbers) from the ASME Section XI Subcommittee on Nuclear Inservice Inspection to the ASME OM Committee. The ASME intended the OM Code to replace Section XI rules for IST and inservice examination of pumps, valves, and dynamic restraints (snubbers), and the Section XI rules for IST and inservice examination of these components that had been incorporated by reference into NRC regulations have been deleted from Section XI.

The ASME OM Code was incorporated by reference in NRC regulations in September 1999, with the following clarification from the NRC: 6 These provisions provide updated rules for the construction of components of light water-cooled nuclear power plants, and for the inservice inspection and inservice testing of those components Further the ASME OM Code is specific to LWRs and LWR components. As such, 10 CFR 50.55a(a)(1)(iv),

10 CFR 50.55a(a)(3)(iii), 10 CFR 50.55a(b)(3), and 10 CFR 50.55a(b)(6) do not apply to non-LWRs. The NRC staff has recently acknowledged that these regulations do not apply to non-LWRs.[1, 3] Therefore, because these design features do not exist in non-LWRs, this regulation is not applicable.

8.3.2 Outdated 10 CFR 50.55a requirements The paragraphs discussed under this section are 10 CFR 50.55a(a)(2)(i)-(a)(2)(ii) and 10 CFR 50.55a(h)(2).

Sections 50.55a(a)(2)(i) and(a)(2)(ii) of 10 CFR both have the following reference, referenced in paragraph (h)(2) of this section. 10 CFR 50.55a(h)(2) states as follows:

Protection systems. For nuclear power plants with construction permits issued after January 1, 1971, but before May 13, 1999, protection systems must meet the requirements in IEEE Std 6

64 FR 51370, September 22, 1999

© NEI 2020. All rights reserved. nei.org 21

October 2020 279-1968, Proposed IEEE Criteria for Nuclear Power Plant Protection Systems, or the requirements in IEEE Std 279-1971, Criteria for Protection Systems for Nuclear Power Generating Stations, or the requirements in IEEE Std 603-1991, Criteria for Safety Systems for Nuclear Power Generating Stations, and the correction sheet dated January 30, 1995. For nuclear power plants with construction permits issued before January 1, 1971, protection systems must be consistent with their licensing basis or may meet the requirements of IEEE Std. 603-1991 and the correction sheet dated January 30, 1995.

Since future non-LWR applications will be filed after 1999, neither IEEE 279-1968, IEEE 279-1971, nor IEEE 603-1991 will apply to such applications. Therefore, the requirements of 10 CFR 50.55a(a)(2)(i)-

(a)(2)(ii) and 10 CFR 50.55a(h)(2) are dated and do not apply to the already-filed non-LWR application or to any future non-LWR application that could be filed. Therefore, 10 CFR 50.55a(h)(3) will apply to non-LWRs going forward. [3]

9 PRIMARY CONTAINMENT LEAKAGE RATE TESTING PROGRAM - 10 CFR 52.79(A)(12) 9.1 Purpose This section explains why 10 CFR 52.79(a)(12) does not apply to non-LWRs. Specifically, 10 CFR 52.79(a)(12), in its entirety, does not apply to non-LWRs, as shown using strike out in the below quoted text:

A description of the primary containment leakage rate testing program, and its implementation, necessary to ensure that the containment meets the requirements of Appendix J to 10 CFR 50; 9.2 Technical Justification 10 CFR 52.79(a)(12) requires compliance with Appendix J to 10 CFR 50. Appendix J, "Primary reactor containment leakage testing for water-cooled power reactors, to 10 CFR Part 50 was developed as a technology-specific appendix for water-cooled reactors. In this appendix are descriptions for necessary tests to verify that the primary containment or related systems do not exceed allowable leakage rates as specified in the designs technical specifications. In addition to confirming that leakage rates are below set limits, monitoring leakage for a water-cooled containment provides confidence that the containment structure is maintained during its service life.

This regulation makes the assumption that the design has a primary reactor containment and that its leakage has a significance to safety. In contrast, these design features are likely not to be present in non-LWRs or not have an impact on safety. As identified in SECY-18-0096, and approved in the corresponding staff requirements memorandum, non-LWRs may rely upon functional containment without a pressure retaining containment structure. Other regulations in 10 CFR 52.79(a) already require a thorough safety analysis and an analysis of the radioactive materials produced during operation. If leakage of any sort were relevant to the design, it would be scoped under other portions of 10 CFR 52.79(a). Because of drastic differences in reactor design between LWR and non-LWR designs, there is no such equivalent system in non-LWRs for which 10 CFR 52.79(a)(12) was written. Therefore, preoperational and verification testing as described in Appendix J does not apply to non-LWRs.

© NEI 2020. All rights reserved. nei.org 22

October 2020 9.3 Regulatory Justification The relevant portion of 10 CFR 52.79(a)(12) for this non-applicability is the following text, A description of the primary containment leakage rate testing program, and its implementation, necessary to ensure that the containment meets the requirements of Appendix J to 10 CFR 50. Appendix to J to 10 CFR Part 50 expressly applies only to water-cooled reactors:

One of the conditions of all operating licenses under this part and combined licenses under part 52 of this chapter for water-cooled power reactors as specified in § 50.54(o) is that primary reactor containments shall meet the containment leakage test requirements set forth in this appendix.

Non-LWRs are not water-cooled nuclear power reactors. Additionally, the NRC staff has recently acknowledged that this regulation does not apply to non-LWRs.[1] Therefore, the design features that are assumed to be present by this regulation do not exist in non-LWRs, and this regulation is not applicable.

10 REACTOR VESSEL MATERIAL SURVEILLANCE PROGRAM - 10 CFR 52.79(A)(13) 10.1 Purpose This section explains why 10 CFR 52.79(a)(13) does not apply to non-LWRs. Specifically, 10 CFR 52.79(a)(13), in its entirety, does not apply to non-LWRs, as shown using strike out in the below quoted text:

A description of the reactor vessel material surveillance program required by Appendix H to 10 CFR Part 50 and its implementation; 10.2 Technical Justification Commercial LWR designs utilize reactor pressure vessels that are important components to the safety of the reactors. Reactor vessels are typically pressure vessels for LWRs because of the pressurized nature of the coolant, among other considerations. Since the reactor pressure vessel is the main boundary for the reactor coolant boundary and is intended to operate for over 40 years without replacement, the structural integrity is of importance from a safety perspective.

Specifically, the structural integrity is determined through fracture mechanics evaluations that include the measurements or estimates of the fracture toughness of the material resulting from exposure to neutron irradiation and the thermal environment. During operation, neutrons escaping from the reactor core impact the reactor pressure vessel beltline materials, causing embrittlement to those materials.

The main factors affecting steel embrittlement include the following [4]:

  • Type of steel and its composition and microstructure
  • Exposure temperature
  • Neutron environment
  • Stress state

© NEI 2020. All rights reserved. nei.org 23

October 2020

  • Combined embrittlement effects To ensure structural integrity, if a reactor pressure vessel using a ferritic material exceeds a neutron fluence of 1017 n/cm2, for neutron energies greater than 1 MeV, in the beltline region of the reactor pressure vessel, a material surveillance program is required by Appendix H to 10 CFR Part 50.

Specifically, it is important for LWRs to maintain the reactor vessel integrity in order for the fission product barrier to be effective, as well as the maintenance of the reactor coolant. 7 This regulation makes the assumption that the design has a reactor pressure vessel, the material of which must be monitored to assure the safe operation of the facility. However, non-LWRs might not use pressure vessels for many reasons, including not having a pressurized system. Further, this regulation discusses concerns with carbon steels, which are common in LWR applications but might not be used in non-LWR designs. Other regulations in 10 CFR 52.79(a) already require a thorough safety analysis, which would encompass degradation and potential leakage or structural support concerns. Because of drastic differences in reactor design between LWR and non-LWR designs, there is no such equivalent system in non-LWRs for which 10 CFR 52.79(a)(13) was written. Therefore, reactor vessel material surveillance program as described in Appendix H does not apply to non-LWRs.

10.3 Regulatory Justification The relevant portion of 10 CFR 52.79(a)(13) for this non-applicability is the following text, A description of the reactor vessel material surveillance program required by Appendix H to 10 CFR Part 50 and its implementation. Appendix H to 10 CFR Part 50 expressly applies only to light water nuclear power reactors:

The purpose of the material surveillance program required by this appendix is to monitor changes in the fracture toughness properties of ferritic materials in the reactor vessel beltline region of light water nuclear power reactors which result from exposure of these materials to neutron irradiation and the thermal environment.

Non-LWRs are not light water nuclear power reactors. Additionally, the NRC staff has recently acknowledged that this regulation does not apply to non-LWRs.[1] Therefore, the design features that are assumed to be present by this regulation do not exist in non-LWRs, and this regulation is not applicable.

11 EFFLUENT MONITORING AND SAMPLING - 10 CFR 52.79(A)(16) 11.1 Purpose This section explains why 10 CFR 52.79(a)(16) does not apply to non-light water reactors. Specifically, 10 CFR 52.79(a)(16) does not apply to non-light water reactors, in part, as shown using strike out in the below quoted text:

(i) The information with respect to the design of equipment to maintain control over radioactive materials in gaseous and liquid effluents produced during normal reactor operations, as described in § 50.34a(d) of this chapter; 7 60 FR 65456, December 19, 1995

© NEI 2020. All rights reserved. nei.org 24

October 2020 (ii) A description of the process and effluent monitoring and sampling program by Appendix I to 10 CFR part 50 and its implementation.

11.2 Technical Justification The control of radioactive materials in liquid and gaseous effluents is required by 10 CFR 52.79 to ensure that occupational dose limits and dose limits to members of the public are maintained to levels as low as reasonably achievable (ALARA) and within design objectives. In order to meet the requirements of this section, an applicant must provide design objectives for limiting effluents and means for keeping radioactive materials in effluents ALARA. In addition, information describing equipment and procedures to control radioactive material in effluents as well as maintenance descriptions for radioactive waste systems must be provided.

The regulations in 10 CFR 52.79(a)(16)(ii) and 10 CFR 50.34a(a) point to Appendix I, Numerical guides for design objectives and limiting conditions for operation to meet the criterion As low as is reasonably achievable for radioactive materials in light-water-cooled nuclear power plants, to 10 CFR Part 50.

Appendix I to 10 CFR Part 50 is technology-specific and was written for the use of LWRs. Applying numerical guides developed for one technology, LWRs, to a different technology, non-LWRs, is not technologically relevant as non-LWRs might have entirely different effluent compositions and pathways.

Further, 10 CFR Part 20, Standards for the protection against radiation, provides numerical guides for many different isotopes that are technology-agnostic and are applicable to non-LWRs. Therefore, Appendix I to 10 CFR Part 50 is not technologically relevant for non-LWRs and does not apply.

11.3 Regulatory Justification The requirements of Appendix I to 10 CFR Part 50 state the applicability of the regulation in the title of the appendix and also in Section II, as follows:

Guides on design objectives for light-water-cooled nuclear power reactors licensed under 10 CFR part 50 or part 52 of this chapter.

Because any potential effluents, and their subsequent limits are dependent on the reactor technology, its important to highlight that this appendix is for LWRs. For non-LWRs, any potential effluents might vary significantly. Therefore, since non-LWRs are not LWRs, 10 CFR 50, Appendix I does not apply.

Furthermore, non-LWR applicants must comply with other portions of 10 CFR 50.34a(d), namely 10 CFR 50.34a(b)(2), and 10 CFR Part 20, which address the control of gaseous and liquid effluents during normal operations and related ALARA considerations.

12 THREE MILE ISLAND REQUIREMENTS - 10 CFR 52.79(A)(17) 12.1 Purpose This section explains why 10 CFR 52.79(a)(17) does not apply to non-LWRs. Specifically, 10 CFR 52.79(a)(17), in its entirety, does not apply to non-LWRs, as shown using strike out in the below quoted text:

© NEI 2020. All rights reserved. nei.org 25

October 2020 The information with respect to compliance with technically relevant positions of the Three Mile Island requirements in § 50.34(f) of this chapter, with the exception of § 50.34(f)(1)(xii), (f)(2)(ix),

(f)(2)(xxv), and (f)(3)(v).

12.2 Technical Justification 10 CFR 50.34(f) was created for LWRs following the Three Mile Island (TMI) Unit 2 accident. The TMI accident occurred on March 28, 1979 and involved a partial meltdown of the Unit 2 reactor core. The accident involved a small radioactive release, but had no detectable health effects on plant workers or the public. The majority of regulatory changes that occurred following the TMI accident were in the areas of emergency response planning, reactor operator training, human factors engineering, and radiation protection.

The TMI accident involved a failure on the secondary side of the plant, specifically of the main feedwater pumps failing to send water to the steam generators. Because heat was not able to be removed from the reactor, the turbine automatically tripped and subsequently, the reactor tripped. To control the increasing pressure on the primary side, the pilot operated relief valve opened, which was located on top of the pressurizer. However, this valve failed to close and became stuck open. Control room instrumentation falsely indicated that the valve was closed, meaning plant personnel were unaware that steam (i.e., cooling water) was being lost through the pressurizer valve. These events were that of a small break LOCA.

This regulation was written specifically to ensure that LWRs in the U.S. were retrofitted to ensure that the probability of an accident such as the TMI accident was reduced or eliminated. Non-LWRs do not use water for cooling, and do not contain a feedwater system, pressurizer, or pilot-operated relief valves on a pressurizer. As noted in Section 4.2.2, a LOCA is a specific major accident for LWRs. Thus, LOCAs might not be possible and likely are not technically relevant for most non-LWR designs. Since the TMI accident was a small break LOCA, there is no discernible analogue in non-LWR designs.

Further, a major issue during the TMI accident was that the instrumentation did not accurately indicate to the control room staff the ongoing conditions in the plant. However, many non-LWRs do not plan to have reactor operators or might not have credited operator actions, such as the operators at TMI.

Instead, the plants may function fully automatically. Although human factors are taken into consideration for usability of the monitoring functions of non-LWR designs, they are not a critical safety consideration as they were during the TMI accident. In conclusion, the highly automated nature of non-LWRs obviates the human errors that occurred during the TMI accident.

12.3 Regulatory Justification The requirements of 10 CFR 52.79(a)(17) point to 10 CFR 50.34(f). Specifically, 10 CFR 50.34(f) states the applicability of the regulation as follows:

In addition to the requirements of paragraph (a) of this section, each applicant for a light-water-reactor construction permit or manufacturing license whose application was pending as of February 16, 1982, shall meet the requirements in paragraphs (f)(1) through (3) of this section.

This regulation applies to the pending applications by Duke Power Company (Perkins Nuclear Station, Units 1, 2, and 3) In addition, each applicant for a design certification, design approval, combined license, or manufacturing license under part 52 of this chapter shall

© NEI 2020. All rights reserved. nei.org 26

October 2020 demonstrate compliance with the technically relevant portions of the requirements in paragraphs (f)(1) through (3) of this section, except for paragraphs (f)(1)(xii), (f)(2)(ix), and (f)(3)(v).

Because non-LWRs are not light water nuclear power reactors, are not expected to be challenged by LOCAs, and operate under different control systems from the LWRs of the 1970s and earlier, the design features assumed by 10 CFR 50.34(f) do not exist. The NRC staff has recently acknowledged that this regulation does not apply to non-LWRs.[1] Therefore, the requirements of 10 CFR 50.34(f) do not apply to non-LWRs.

13 SEVERE ACCIDENTS - 10 CFR 52.79(A)(38) 13.1 Purpose This section explains why 10 CFR 52.79(a)(38) does not apply to non-LWRs. Specifically, no portion of 10 CFR 52.79(a)(38) applies to non-LWRs, as shown using strike out in the below quoted text:

For light-water reactor designs, a description and analysis of design features for the prevention and mitigation of severe accidents, e.g., challenges to containment integrity caused by core-concrete interaction, steam explosion, high-pressure core melt ejection, hydrogen combustion, and containment bypass.

13.2 Technical Justification The NRC historically has defined an LWR severe accident as an accident involving multiple failures of equipment or function, whose likelihood is generally lower than design-basis accidents, but where consequences may be higher. 8 Thus, by definition, severe accidents are postulated events whose probability of occurrence is so low that they are excluded from the spectrum of design-basis accidents postulated by NRC regulations. Moreover, they involve multiple failures that may result in changes to the reactor core configuration and significant radionuclide releases from the damaged core. For LWRs licensed under Part 52, 10 CFR 52.79(a)(38) makes this clear insofar as it refers to severe accidents as involving challenges to containment integrity caused by core-concrete interaction, steam explosion, high-pressure core melt ejection, hydrogen combustion, and containment bypass.

It is recognized that the requirement to consider severe accident mitigation design alternatives (SAMDAs) is a NEPA-based requirement derived from a judicial decision 9 and implemented through certain regulations in 10 CFR Part 51, Environmental protection regulations for domestic licensing and related regulatory functions. However, the NRCs concept of credible severe accident progression sequences (and related SAMDAs) does not appear to apply to other technologies, outside of LWRs.

The example severe accidents (i.e., challenges to containment integrity caused by core-concrete interaction, steam explosion, high-pressure core melt ejection, hydrogen combustion, and containment bypass) do not have an equivalent in non-LWRs and do not necessitate further evaluation. Therefore, the requirements of 10 CFR 52.79(a)(38) do not apply and no further information should be included in the FSAR.

8 NUREG-1437, Vol. 1 at 5-1 (1996); NUREG-1437, Rev. 1 at 1-27 (2013) 9 See Limerick Ecology Action v. NRC, 869 F.2d 719 (3rd Cir. 1989).

© NEI 2020. All rights reserved. nei.org 27

October 2020 13.3 Regulatory Justification The requirements of 10 CFR 52.79(a)(38) state the applicability of the regulation as follows:

For light-water reactor designs, a description and analysis of design features for the prevention and mitigation of severe accidents, e.g., challenges to containment integrity caused by core-concrete interaction, steam explosion, high-pressure core melt ejection, hydrogen combustion, and containment bypass.

The NRC staff has recently acknowledged that this regulation does not apply to non-LWRs and could be included in the non-LWR design probabilistic risk assessment (PRA), as stated, in part:

Furthermore, 10 CFR 52.47(a)(23), 10 CFR 52.79(a)(38), 10 CFR 52.137(a)(23), and 10 CFR 52.157(f)(23) require that applications for LWR designs include a description and analysis of design features for the prevention and mitigation of severe accidents and their consequences.

The risk consideration associated with these BDBEs [beyond design basis events], as well as other low frequency event sequences, will be considered as part of the required PRA.

Because non-LWRs are not an LWR design, the design features assumed by 10 CFR 52.79(a)(38) do not exist. Furthermore, other regulations that are applicable to non-LWRs require applicants to address the adequacy of SSCs for the prevention and mitigation of the consequences of accidents, including BDBEs.

Therefore, the requirements of 10 CFR 52.79(a)(38) do not apply.

14 STANDARD REVIEW PLAN EVALUATION - 10 CFR 52.79(A)(41) 14.1 Purpose This section explains why 10 CFR 52.79(a)(41) does not apply to non-light water reactors. Specifically, 10 CFR 52.79(a)(41), in its entirety, does not apply to non-light water reactors, as shown using strike out in the below quoted text:

For applications for light-water-cooled nuclear power plant combined licenses, an evaluation of the facility against the Standard Review Plan (SRP) revision in effect 6 months before the docket date of the application. The evaluation required by this section shall include an identification and description of all differences in design features, analytical techniques, and procedural measures proposed for a facility and those corresponding features, techniques, and measures given in the SRP acceptance criteria. Where a difference exists, the evaluation shall discuss how the proposed alternative provides an acceptable method of complying with the Commission's regulations, or portions thereof, that underlie the corresponding SRP acceptance criteria. The SRP is not a substitute for the regulations, and compliance is not a requirement 14.2 Technical Justification 10 CFR 52.79(a)(41) specifically requires applicants for an LWR combined license to perform an evaluation against the light water SRP, otherwise known as NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition. Because NUREG-0800 was written specifically for LWRs, it makes assumptions that the design that would follow this guidance would be an LWR. Non-LWRs do not have the design features assumed by NUREG-0800.

© NEI 2020. All rights reserved. nei.org 28

October 2020 Although there are several standard review plans issued as NUREGs, none of those standard review plans apply to the review of a non-LWR license application. Therefore the requirements of 10 CFR 52.79(a)(41) are not technically relevant for non-LWRs.

14.3 Regulatory Justification 10 CFR 52.79(a)(41) describes its applicability as follows:

For applications for light-water-cooled nuclear power plant combined licenses, an evaluation of the facility against the Standard Review Plan (SRP) revision in effect 6 months before the docket date of the application Because non-LWRs are not light-water-cooled nuclear power plants, the design features assumed by 10 CFR 52.79(a)(41) do not exist. The NRC staff has recently acknowledged that this regulation does not apply to non-LWRs.[1] Therefore, the requirements of 10 CFR 52.79(a)(41) do not apply.

15 ANTICIPATED TRANSIENTS WITHOUT SCRAM - 10 CFR 52.79(A)(42) 15.1 Purpose This section explains why 10 CFR 52.79(a)(42) does not apply to non-LWRs. Specifically, 10 CFR 52.79(a)(42), in its entirety, does not apply to non-LWRs, as shown using strike out in the below quoted text:

Information demonstrating how the applicant will comply with requirements for reduction of risk from anticipated transients without scram (ATWS) events in § 50.62 of this chapter.

15.2 Technical Justification Anticipated transient without scram is defined in 10 CFR 50.62, Requirements for the reduction of risk from anticipated transients without scram (ATWS) events for light-water-cooled nuclear power plants, in the following way:

an anticipated operational occurrence as defined in appendix A of this part followed by the failure of the reactor trip portion of the protection system specified in General Design Criterion 20 of appendix A of this part.

Appendix A, General design criteria for nuclear power plants, to 10 CFR Part 50 defines anticipated operational occurrences as follows:

those conditions of normal operation which are expected to occur one or more times during the life of the nuclear power unit and include but are not limited to loss of power to all recirculation pumps, tripping of the turbine generator set, isolation of the main condenser, and loss of all offsite power.

Concern related to the consequences of an ATWS, the uncertainty around the reliability of the reactor protection system, and some precursor events in the industry (primarily an event at Browns Ferry 3) led to the ATWS rule in June 1984. The rule included required improvements in the design and operation of LWRs to, reduce the likelihood of failure of the reactor protection system to shut down the reactor

© NEI 2020. All rights reserved. nei.org 29

October 2020 (scram) following anticipated transients and to mitigate the consequences of anticipated transients without scram (ATWS) event. 10 The ATWS rule was developed for LWRs and has specific equipment requirements for various types of LWRs. These requirements include the following items:

  • For pressurized water reactors, equipment to automatically initiate the auxiliary (or emergency) feedwater system and initiate a turbine trip
  • For boiling water reactors, an alternate rod injection system that is independent from the existing reactor trip system Non-LWRs generally do not rely on auxiliary or emergency feedwater systems and do not use borated water for reactivity control. Because of the substantial differences in design of non-LWRs and LWRs, the equipment requirements do not have technical relevance.

The ATWS rule was developed in response to concern about ATWS events for LWRs. The requirements of 10 CFR 50.62 are specific to LWRs and do not apply directly to non-LWRs. Other regulations in 10 CFR 52.79(a) already require a thorough safety analysis. If ATWS events were relevant to the design, it would be scoped under other portions of 10 CFR 52.79(a). Therefore, the ATWS requirements of 10 CFR 52.79(a)(44) and 10 CFR 50.62 are not technically relevant for non-light water reactors.

15.3 Regulatory Justification The relevant portion of 10 CFR 52.79(a)(42) for this non-applicability is the following text:

Information demonstrating how the applicant will comply with requirements for reduction of risk from anticipated transients without scram (ATWS) events in § 50.62 of this chapter 10 CFR 50.62 specifically applies to commercial light water cooled nuclear reactors, as stated in 10 CFR 50.62(a):

The requirements of this section apply to all commercial light-water-cooled nuclear power plants, other than nuclear power reactor facilities for which the certifications required under § 50.82(a)(1) have been submitted.

Non-LWRs are not light-water-cooled nuclear power plants. Additionally, the NRC staff has recently acknowledged that this regulation does not apply to non-LWRs.[1] Other regulations in 10 CFR 52.79(a) already require a thorough safety analysis. If ATWS events were relevant to the design, it would be scoped under other portions of 10 CFR 52.79(a). Therefore, the design features that are assumed to be present by this regulation do not exist in non-LWRs and this regulation is not applicable.

10 49 FR 26036, June, 1984

© NEI 2020. All rights reserved. nei.org 30

October 2020 16 REFERENCES

[1] Nuclear Regulatory Commission Staff, Non-light water review strategy. Sep. 2019.

[2] Christopher Boyd, Pressurized Thermal Shock, PTS. Nuclear Regulatory Commission, 2008.

[3] Nuclear Regulatory Commission Staff, "Draft White Paper Analysis of Applicability of NRC Regulations for Non-Light Water Reactors." Sep. 2020.

[4] L. E. Steele, Neutron Irradiation Embrittlement of Reactor Pressure Vessel Steels, IAEA, Vienna, Austria, Technical Report 163, 1975.

© NEI 2020. All rights reserved. nei.org 31