L-2021-099, 2020 Annual Radiological Environmental Operating Report

From kanterella
(Redirected from ML21133A478)
Jump to navigation Jump to search
2020 Annual Radiological Environmental Operating Report
ML21133A478
Person / Time
Site: Turkey Point  
Issue date: 05/10/2021
From: Hess R
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2021-099
Download: ML21133A478 (55)


Text

F=PL.

U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-00001 Re:

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 2020 Annual Radiological Environmental Operating Report May 10, 2021 L-2021-099 10 CFR 50.36b Enclosed is the 2020 Annual Radiological Environmental Operating Report for Turkey Point Units 3 and 4, as required by Technical Specification 6.9.1.3.

Should there be any questions or comments regarding this information, please contact Mr. Robert J.

Hess, Licensing Manager, at (305) 246-4112.

Licensing Manager Turkey Point Nuclear Plant SM Enclosure cc:

Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, Turkey Point Plant Florida Power & Light Company 9760 S.W. 3441" Street Homestead, FL 33035

Plant: Turkey Point Nuclear Units 3 & 4 Page 1 of 54 YEAR: 2020 Docket NOS Number: 50-250, 50-251 Annual Radiological Environmental Operating Report

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 2 of 54 Annual Radiological Environmental Operating Report TABLE OF CONTENTS 1.1 EXECUTIVE

SUMMARY

.......................................................................................................... 5 1.2 Radiological Environmental Monitoring Program.................................................................. 5 1.3 Reporting Levels................................................................................................................ 6 1.4 Sample Deviations............................................................................................................. 6 1.5 Program Modifications........................................................................................................ 6

2.1 INTRODUCTION

..................................................................................................................... 7 2.2 Radiological Environmental Monitoring Program.................................................................. 7 A. Purpose......................................................................................................................... 7 2.3 Pathways Monitored........................................................................................................... 8 2.4 Land Use Census.............................................................................................................. 8 3.0 RADIOLOGICAL ENVIRONMENTAL SAMPLING PROGRAM REQUIREMENTS...................... 9 4.1 INTERPRETATION AND TRENDS OF RESULTS.................................................................. 16 4.2 Air Particulate and Radioiodine Sample Results................................................................ 16 4.3 Thermoluminescent Dosimetry (TLD) Sample Results....................................................... 17 4.4 Waterborne Sample Results............................................................................................. 17 4.4.1 Surface Water Results.................................................................................................17 4.4.2 Sediment Sample Results............................................................................................18 4.5 Ingestion Sample Results................................................................................................. 18 4.5.1 Crustacea and Fish Sample Results...............................................................................18 4.5.2 Broad Leaf Vegetation Sample Results...........................................................................18 4.6 Land Use Census Results................................................................................................ 18 4.7 Interlaboratory Comparison Results.................................................................................. 26 5.0 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

......................... 26

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 3 of 54 Annual Radiological Environmental Operating Report ATTACHMENTS

- Sample Deviations..................................................................................................... 30 - Monitoring Results Tables.......................................................................................... 31 - Interlaboratory Comparison Program Results.............................................................. 48 1.0 Summary................................................................................................................................... 48 - Industry Initiative Ground Water Protection Program, 2020.......................................... 51 1.0 Description of Program............................................................................................................... 51 2.0 Discussion................................................................................................................................. 51 3.0 Results............................................................................................................................... 51 TABLES Table 1: Exposure Pathway - Airborne..................................................................................... 9 Table 2: Exposure Pathway - Direct Radiation........................................................................ 10 Table 3: Exposure Pathway - Waterborne.............................................................................. 12 Table 4: Exposure Pathway - Ingestion.................................................................................. 13 Table 5: Land Use Census - 2020 Nearest Residence, Garden and Milk Animal Within 5 Miles........................................................................................................................ 19 Table 6: Radiological Environmental Monitoring Program Summary........................................ 27 Table 7: Sample Deviations Table.......................................................................................... 30 Table 8: Air Particulate - Gross Beta...................................................................................... 32 Table 9: Air Particulate Composite - Gamma.......................................................................... 33 Table 10: Air Cartridges - Iodine-131..................................................................................... 34 Table 11: Direct Radiation - Indicators................................................................................... 35 Table 12: Direct Radiation-Controls...................................................................................... 35 Table 13: Surface Water - Tritium and Gamma....................................................................... 36 Table 14: Shoreline Sediment - Gamma................................................................................. 37 Table 15: Crustacea - Gamma................................................................................................ 38 Table 16: Fish - Gamma......................................................................................................... 39 Table 17: Broad Leaf Vegetation - Gamma............................................................................. 40

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 4 of 54 Annual Radiological Environmental Operating Report TABLES (CONT'D)

Table 18: Supplemental Direct Radiation - Indicators.............................................................. 41 Table 19: Supplemental Air Particulate - Gross Beta............................................................... 42 Table 20: Supplemental Air Particulate Composite - Gamma................................................... 43 Table 21: Supplemental Air Cartridges - Iodine-131................................................................ 44 Table 22: Supplemental Surface Water - Tritium and Gamma................................................. 45 Table 23: Supplemental Shoreline Sediment - Gamma........................................................... 46 Table 24: Supplemental Broad Leaf Vegetation - Gamma....................................................... 47 Table 25: DOE's Mixed Analyte Performance Evaluation Program (MAPEP) 42 results................................................................................................................................... 49 Table 26: DOE's Mixed Analyte Performance Evaluation Program (MAPEP) 43 results................................................................................................................................... 50 Table 27: Ground Water - Tritium........................................................................................... 52 FIGURES Figure 1: Sample Collection Sites - Near Station.................................................................... 14 Figure 2: Sample Collection Sites - Distant from Station......................................................... 15 Figure 3: Turkey Point 2020 REMP Gross Beta in Air pCi/m3.................................................. 16 Figure 4: 2020 PTN Direct Exposure TLDs: Quarterly Collection............................................. 17

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 5 of 54 Annual Radiological Environmental Operating Report 1.1 EXECUTIVE

SUMMARY

1.2 Radiological Environmental Monitoring Program The data obtained through the Turkey Point Radiological Environmental Monitoring Program (REMP) verifies that the levels of radiation and concentrations of radioactive materials in environmental samples are not increasing. These measurements verify that the dose or dose commitment to members of the public, due to operation of Turkey Point Units 3 & 4, during the surveillance year, is well within the limits established by 10 CFR 50, Appendix I. The sampling period was from January 1, 2020 to December 31, 2020. Additionally, supplemental samples collected by the State of Florida, DOH, do not indicate adverse trends in the radiological environment.

All required lower limit of detection (LLD) capabilities were achieved in all sample analyses during 2020, as required by the Turkey Point Units 3 & 4 Technical Specifications. No measurable levels of radiation above baseline levels attributable to Turkey Point Nuclear operation were detected in the vicinity of PTN. The 2020 Radiological Environmental Monitoring Program thus substantiated the adequacy of source control and effluent monitoring at Turkey Point Nuclear with no observed impact of plant operations on the environment.

Turkey Point Nuclear established the REMP prior to the stations becoming operational to provide data on background radiation and radioactivity normally present in the area. PTN has continued to monitor the environment by sampling air, water, sediment, crustacea, fish and broadleaf vegetation, as well as measuring direct radiation. PTN also samples milk if milk-producing animals used for human consumption are present within five miles (8 km) of the plant.

The REMP includes sampling indicator and control locations within an approximate 20-mile radius of the plant. The REMP utilizes indicator locations near the site to show any increases or buildup of radioactivity that might occur due to station operation and control locations farther away from the site to indicate the presence of only naturally occurring radioactivity. PTN personnel compare indicator results with control results to assess any impact PTN operation might have had on the surrounding environment.

In 2020, environmental samples were collected for radiological analysis. The results of indicator locations were compared with control locations. It was concluded that no significant relationship exists between PTN operation and effect on the area around the plant. The review of 2020 data showed radioactivity levels in the environment were undetectable in many locations and near background levels in significant pathways.

Radiological environmental monitoring for the Turkey Point Plant is conducted by the State of Florida, Department of Health (DOH). Samples are collected and analyzed by DOH personnel. Samples are analyzed at the DOH Environmental Radiation Control Laboratory in Orlando, Florida. The 2020 Radiological Surveillance Quarterly Report data is provided by the State of Florida Bureau of Radiation Control and is presented in Attachment 2.

The State of Florida is not involved in the (Industry Initiative) ground water monitoring program.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 6 of 54 Annual Radiological Environmental Operating Report 1.3 Reporting Levels No samples equaled or exceeded reporting levels.

1.4 Sample Deviations During 2020, environmental sampling was performed for seven media types addressed in the ODCM and for direct radiation. A total of 801 samples of the 802 scheduled were obtained. Of the scheduled samples, 99.9 percent were collected and analyzed in accordance with the requirements specified in the ODCM. contains the listing of sample deviations and actions taken.

1.5 Program Modifications There were no program modifications during the reporting period.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 7 of 54 Annual Radiological Environmental Operating Report

2.1 INTRODUCTION

This report is submitted pursuant to Specification 6.9 of Turkey Point Units 3 & 4 Technical Specifications. The Annual Radiological Environmental Operating Report provides information, summaries and analytical results pertaining to the Radiological Environmental Monitoring Program for the calendar year indicated. This report covers surveillance activities described in the Offsite Dose Calculation Manual (ODCM) meeting the requirements of Unit 3 and Unit 4 Technical Specifications.

2.2 Radiological Environmental Monitoring Program The Radiological Environmental Monitoring Program for the Turkey Point Plant is conducted pursuant to Control 5.1 of Turkey Point Unit 3 & 4 ODCM.

A. Purpose The purpose of the Radiological Environmental Monitoring Program is to provide representative measurements of radiation and of radioactive materials in those exposure pathways and for those radionuclides which lead to the highest potential radiation exposures of members of the public resulting from station operation.

The Radiological Environmental Monitoring Program also supplements the radiological effluent monitoring program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and the modeling of the environmental exposure pathways.

Sample Locations, Types and Frequencies:

Direct radiation gamma exposure rate is monitored continuously at 23 locations by thermoluminescent dosimeters (TLDs). TLDs are collected and analyzed quarterly.

Airborne radioiodine and particulate samplers are operated continuously at six locations. Samples are collected and analyzed weekly. Analyses include Iodine-131, gross beta, and gamma isotopic measurements.

Surface water samples are collected from three locations. Samples are collected and analyzed monthly. Analyses include gamma isotopic and tritium measurements.

Shoreline sediment samples are collected from three locations coinciding with the locations for surface water samples. Samples are collected and analyzed semi-annually. Sediment samples are analyzed by gamma isotopic measurements.

Fish and invertebrate samples are collected from two locations coinciding with two of the locations for surface water samples. Samples are collected and analyzed semi-annually. Fish and invertebrate samples are analyzed by gamma isotopic measurements.

Broad leaf vegetation samples are collected from three locations. Samples are collected and analyzed monthly. Broad leaf vegetation samples are analyzed by gamma isotopic measurements.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 8 of 54 Annual Radiological Environmental Operating Report Table 1 through 4 provides specific information pertaining to sample locations, types, and frequencies.

Note: Ground Water Protection, NEI Initiative: The program and results are described in Attachment 4.

2.3 Pathways Monitored The airborne, direct radiation, waterborne and ingestion pathways are monitored as required by Control 5.1 of Turkey Point Unit 3 & 4 ODCM. A description of the REMP utilized to monitor the exposure pathways is described in the attached Tables and Figures.

Section 4.0 of this report provides a discussion of 2020 sampling results with Section 5.0 providing a summary of results for the monitored exposure pathways.

2.4 Land Use Census PTN conducts a land use census annually, as required by Turkey Point Units 3 & 4 ODCM. The purpose of this census is to identify changes in uses of land within five miles of PTN that would require modifications to the REMP and the Offsite Dose Calculation Manual (ODCM). Section 4.5 on the report contains a narrative on the results of the 2020 land use census.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 9 of 54 Annual Radiological Environmental Operating Report 3.0 RADIOLOGICAL ENVIRONMENTAL SAMPLING PROGRAM REQUIREMENTS Table 1: Exposure Pathway - Airborne Requirement Sample Point Description Distance and Direction Sampling and Collection Frequency Type and Frequency of Analyses RADIOIODINE AND PARTICULATES 5 sample indicator locations and 1 sample control location.

T-51 (2 mi. NNW) - Entrance Area to Biscayne National Park.

T-57 (4 mi. NW) - Siren Pole 27, intersection of SW 112th Ave and SW 304th St.

T-58 (1 mi. NW) - Turkey Point Entrance Road.

T-72 (<1 mi. WSW) - Just before entrance to Land Utilizations access gate.

T-41 (1.6 mi. WNW) - Palm Dr.

West of FPL Satellite School near the site boundary.

T-64* (22 mi. NNE) - Natoma Substation, 2475 SW 16 Ct.

Continuous sampler operation with sample collection weekly or more frequently if required by dust loading.

Radioiodine Canisters - I-131 analysis weekly.

Air Particulate - Gross beta radioactivity analysis following filter change.

Air Particulate - Gamma Isotopic analysis quarterly.

  • Denotes Control sample

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 10 of 54 Annual Radiological Environmental Operating Report Table 2: Exposure Pathway - Direct Radiation Requirement Sample Point Description Distance and Direction Sampling and Collection Frequency Type and Frequency of Analyses TLDS 22 indicator sample locations and 1 control sample location.

N-2 (2 mi N) - Convoy Point N-7 (7.1 mi N) - Black Point Marina parking lot on siren pole N-10 (10.6 mi N) - Old Cutler Rd across from Perdue Med. Ctr. On siren pole.

NNW-2 (2.2 mi NNW) - East End of N. Canal Dr. on siren pole E. of 117th Ave.

NNW-10 (9.2 mi NNW) - Bailes Rd.

E. of US 1 on siren pole.

NW-1 (1.4 mi NW) - Turkey Point Entrance Rd.

NW-5 (3.9 mi NW) - Intersection of Mowry Dr. and 117th Ave. on siren pole.

NW-10 (10 mi NW) - On Newtown Rd. N. of Coconut Palm Drive on siren pole.

W-5 (5.3 mi W) - Palm Drive 0.3 mi west of Tallahassee Rd.

WNW-10 (9.8 mi WNW) - NW 2nd Ave. S. of Campbell Dr. at Hmstd.

Middle School on siren pole.

W-1 (0.7 mi W) - On site north side of Discharge Canal.

Quarterly mR exposure quarterly.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 11 of 54 Annual Radiological Environmental Operating Report Table 2: Exposure Pathway - Direct Radiation Requirement Sample Point Description Distance and Direction Sampling and Collection Frequency Type and Frequency of Analyses TLDS (Contd) 22 indicator sample locations and 1 control sample location.

W-9 (8.6 mi W) - Card Sound Rd. 0.6 mi SSE of US 1 on siren pole.

WSW-8 (7.8 mi WSW) - Card Sound Rd. 3.4 mi. SSE of US 1 on siren Pole.

SW-1 (1 mi SW) - On site near land utilization offices.

SSE-1 (1 mi SSE) - On-site South-East side of cooling canals at Turtle Point.

SW-8 (8 mi SW) - Card Sound Rd. 5 mi. SSE of US 1 at entrance to Navy facility.

SSW-5 (5 mi SSW) - On site, southwest corner of cooling canals.

SSW-10 (10 mi SSW) - At Card Sound Bridge on siren pole.

S-5 (5 mi S) - On site, south east end of cooling canals.

S-10 (10 mi S) - Card Sound Road at Steamboat Creek.

SSE-10 (9 mi SSE) - Ocean Reef.

NNE-22* (22.6 mi NNE) - Natoma Substation.

WNW2 (1.6 mi WNW) - Palm Dr.

West of FPL Satellite School, near Site Boundary.

Quarterly mR exposure quarterly.

  • Denotes Control sample

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 12 of 54 Annual Radiological Environmental Operating Report Table 3: Exposure Pathway - Waterborne Requirement Sample Point Description Distance and Direction Sampling and Collection Frequency Type and Frequency of Analyses SURFACE WATER 2 indicator sample locations and 1 control sample location.

T-42 (<1 mi. ENE) - Biscayne Bay at Turkey Point.

T-81 (6 mi. S) - Card Sound, near Mouth of Old Discharge Canal.

T-67* (13-18 mi. N, NNE) - Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park Grab samples Monthly Gamma isotopic analysis and tritium analysis monthly.

SEDIMENT FROM SHORELINE 2 indicator sample locations and 1 control sample location. Locations coincide with the surface water sample locations.

T-42 (<1 mi ENE) - Biscayne Bay at Turkey Point.

T-81 (6 mi. S) - Card Sound, near Mouth of Old Discharge Canal.

T-67* (13-18 mi. N, NNE) - Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park Semi-annually Gamma isotopic analysis semi-annually.

  • Denotes Control sample

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 13 of 54 Annual Radiological Environmental Operating Report Table 4: Exposure Pathway - Ingestion Requirement Sample Point Description Distance and Direction Sampling and Collection Frequency Type and Frequency of Analyses CRUSTACEA AND FISH 1 indicator sample location and 1 control sample location.

T-81 (6 mi. S) - Card Sound, near Mouth of Old Discharge Canal.

T-67* (13-18 mi. N, NNE) - Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park Semi-annually Gamma isotopic analysis semi-annually.

BROADLEAF VEGATATION 2 indicator sample locations and 1 control sample location.

T-40 (3 mi W) - South of Palm Dr. on S.W. 117th Street Extension.

T-41 (2 mi WNW) - Palm Dr. West of FPL Satellite School near the site boundary.

T-67* (13-18 mi. N, NNE) - Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park Monthly Gamma isotopic analysis monthly.

  • Denotes Control sample

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 14 of 54 Annual Radiological Environmental Operating Report Figure 1: Sample Collection Sites - Near Station

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 15 of 54 Annual Radiological Environmental Operating Report Figure 2: Sample Collection Sites - Distant from Station

Figure 3: Turkey Point 2020 REMP Gross Beta in Air, pCi/m3 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0.00 13 5

7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 week of year Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 16 of 54 Annual Radiological Environmental Operating Report 4.1 INTERPRETATION AND TRENDS OF RESULTS 4.2 Air Particulate and Radioiodine Sample Results In 2020 there were no samples above the LLD for I-131. Indicator gross beta air particulate results for 2020 were comparable to results obtained from 2017-2019 of the operational REMP. Results are reported in picocuries per cubic meter (pCi/m3).

Monitoring Period Result 2017 - 2019 (Minimum Value) 0.002 2020 Average Value 0.012 2017 - 2019 (Maximum Value) 0.032 Gross beta activity is attributed to naturally occurring radionuclides. Table 6, which include gross beta concentrations and provide a comparison of the indicator and control means and ranges emphasizes the consistent trends seen in this pathway to support the presence of naturally occurring activity. Figure 3 is a comparison of the weekly Gross Beta results for 2020.Therefore, it can be concluded that the airborne pathway continues to be unaffected by Turkey Point Nuclear operations.

Minimum Average Maximum Conc. pCi/m3

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 17 of 54 Annual Radiological Environmental Operating Report 4.3 Thermoluminescent Dosimetry (TLD) Sample Results Turkey Point Nuclear reports relies on comparison of the indicator locations to the control as a measure of plant impact. Turkey Point Nuclears comparison of the indicator to the control, as seen in Table 6, identified no noticeable trend that would indicate that the ambient radiation levels are being affected by plant operations. In addition, the quarterly indicator averages shown in the TLD radiation dose comparison graph below shows the 2020 indicator results are comparable to control location results. Overall, Turkey Point Nuclear concluded that the ambient radiation levels are not being affected by plant operations.

4.4 Waterborne Sample Results Analytical results for 2020 surface water samples were similar to those reported in previous years. Gamma radionuclides and tritium analytical results for 2020 waterborne samples were below the ODCM-required LLD similar to those reported in previous years. These results are further explained below.

4.4.1 Surface Water Results Samples were collected from two indicator and one control location and analyzed for gamma radionuclides and tritium. Tritium was detected in 2 out of 24 indicator location samples with an average concentration of 93 pCi/L which is consistent with results seen in previous operational years. There were no plant related gamma radionuclides detected in any of the control or indicator location samples. Therefore, the operation of Turkey Point Nuclear had no definable impact on this waterborne pathway during 2020.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 18 of 54 Annual Radiological Environmental Operating Report 4.4.2 Shoreline Sediment Sample Results Sediment samples were collected from two indicators and one control location in 2020 and analyzed for gamma radionuclides. Plant related gamma radionuclides were below the LLD limits at both indicator and control locations. Turkey Point Nuclear operations had no significant impact on the environment or public by this waterborne pathway.

4.5 Ingestion Sample Results 4.5.1 Crustacea and Fish Sample Results Crustacea and Fish samples were collected from one indicator and one control location and analyzed for gamma radionuclides. In 2020, gamma radionuclides were below detectable limits which are consistent with the results seen in previously operational years. Therefore, based on these measurements, Turkey Point Nuclear operations had no significant radiological impact upon the environment or public by this ingestion pathway.

4.5.2 Broad Leaf Vegetation Sample Results The REMP has detected radionuclides prior to 1990 that are attributable to other sources. These include the radioactive plume release due to reactor core degradation at Chernobyl Nuclear Power Plant in 1986 and atmospheric weapons testing.

In 2020, Broad Leaf Vegetation samples were collected from two indicator and one control locations and analyzed for gamma radionuclides. The 2020 Cs-137 was detected in samples collected from the indicator and control locations. This activity identified could be from weapons fallout testing 30-40 years ago and reactor accidents at Chernobyl and are contributors. Therefore, based on these measurements, Turkey Point Nuclear operations had no significant radiological impact upon the environment or public by this ingestion pathway.

4.6 Land Use Census Results The latest land use census (performed in 2020) did not identify any new locations that yielded a calculated dose or dose commitment greater than those currently calculated (see Table 5).

The land use census identified no changes in the new resident census.

There were no changes in the milk cows/goats or garden census in 2020.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 19 of 54 Annual Radiological Environmental Operating Report Table 5: Land Use Census -2020 Nearest Residence, Garden, and Milk Animal Within Five Miles SECTOR NEAREST RESIDENCE/BUSINESS NEAREST GARDEN (A)

NEAREST MILK ANIMAL N

1.9 mi @ 349° 1.98 mi @ 349° 2.0 mi @ 354° NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW 1.7 mi @ 302° 3.7 mi @ 302° 4.5 mi @ 303° 6.0 mi @ 295° NW 3.6 mi @ 304° 3.7 mi @ 311° 3.8 mi @ 316° 3.9 mi @ 314° NNW 4.4 mi @ 333° 4.7 mi @ 328° 4.4 mi @ 332° 4.7 mi @ 328° (A) - Only gardens with an estimated total area of 500 square feet, or more, and producing green leafy vegetables are considered.

  • - No suitable sites were located within a five-mile range.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 20 of 54 Annual Radiological Environmental Operating Report TURKEY POINT RESIDENCE SURVEY RESULTS August 2020 Sector Range Bearing Nearest Residence/Business Location N (A) 1.9 miles 349° This is the Homestead Bayfront Park complex. Contact is Jim Wyath. Office hours are 8:30 to 4:30, 7 days a week. Some occasional overnight recreational occupancy (up to 4 nights) on boats at the marina. Approximately 25 workers, 7 days a week, hours and number of varies. Summer weekends can see 1000+

visitors. There is always someone here 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> with more workers in the summer than the rest of the year (February thru September have the highest peak of workers). LaPlaya restaurant is open at the park with 8 to 10 employees weekdays from 11am to 8:30pm. Weekends open till 10:00 and may have up to 12 employees. N25° 27.683 W80° 20.200.

N (B) 1.98 miles 349° South Glade Outfitters. Located on opposite side of building from office of Homestead Bayfront Park. Manager is Robert and have 2 employees. Hours are M - Th 7 am to 5 pm. Fri - Sun 7 am -

6 pm. Hours may vary depending on the weather.

N25° 27.767 W80° 20.206.

N (C) 2.0 miles 354° Biscayne National Park at Convoy Point. No admin staff onsite due to Covid-19. Calls have not been returned. Contact includes J. Ernest Jutte, Chief Administration, 305-242-7721 (office) 202-438-6636 (mobile) and Cindy Holl (administrator) 239-695-1114.

N25° 27.817 W80° 20.067.

NNE No residences were located within a five-mile range.

NE No residences were located within a five-mile range.

ENE No residences were located within a five-mile range.

E No residences were located within a five-mile range.

ESE No residences were located within a five-mile range.

SE No residences were located within a five-mile range.

SSE No residences were located within a five-mile range.

S No residences were located within a five-mile range.

SSW No residences were located within a five-mile range.

SW No residences were located within a five-mile range.

WSW No residences were located within a five-mile range.

W No residences were located within a five-mile range.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 21 of 54 Annual Radiological Environmental Operating Report TURKEY POINT RESIDENCE SURVEY RESULTS August 2020 (cont.)

Sector Range Bearing Nearest Residence/Business Location WNW (A) 1.7 miles 302° FP&L daycare center and shooting range near the entrance to the Turkey Point Plant. Contact is Yudisvel Judy Diaz, Director.

There are 11 employees with 60 children currently enrolled, ages 6 months to 5 yrs. Occasionally, they will have school aged children. The center is open from 6am to 6pm Monday thru Friday. The number of people and times at the shooting range varies. N25° 26.817 W80° 21.217.

WNW (B) 3.7 miles 302° Two elderly people live at 11790 Canal Drive on the south side of Canal Drive (SW 328th St) west of SW 117th Ave (no gardens).

Their son lives onsite on weekends, 2-3 nights/week. Residents plan on selling soon. Next door, to the east, is a makeshift produce stand which sells coconuts, limes, mandarin oranges, flowers, garlic, mangoes, papaya, avocado, honey, melons, sugar cane, ginger, plantains and pumpkins. Is not associated with the house next door. One employee may be working there during normal hours. N25° 27.767 W80° 22.867.

NW (A) 3.6 miles 304° The Waste Management Homestead Landfill is located north of Canal Drive (SW 328th St) and east of SW 117th Ave. There are 9 full time employees onsite Monday thru Friday usually from 7 am to 3:30 pm. N25° 27.833 W80° 22.767.

NW (B) 3.7 miles 311° 11000 SW 320th St. Per property records, this house is on land zoned agriculture and the owners live in Texas. Unable to verify if anyone lives there because the gate is locked and the residence is too far from the road to see anything.

N25° 28.217 W80° 22.567.

NW (C) 3.8 miles 316° High Hope Nursery at 11400 SW 316th St. Contact is George Sprinkle, Owner and General Manager. This nursery has approximately 35 employees. Hours of operations are 7am to 5pm Monday thru Friday, with some work on Saturdays until noon. A couple lives here that also provide security.

N25° 28.441 W80° 22.430.

NW (D) 3.9 miles 314° Snapper Creek Nursery at 11600 SW 316th Street. 14 workers that work Monday thru Friday 7 am to 5 pm. Contact is Elmer.

Security is provided by another person who lives onsite.

N25° 28.444 W80° 22.560.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 22 of 54 Annual Radiological Environmental Operating Report TURKEY POINT RESIDENCE SURVEY RESULTS August 2020 (cont.)

Sector Range Bearing Nearest Residence/Business Location NNW (A) 4.4 miles 333° 29800 SW 107th Ave. Per property records, this is a small one bedroom residence on land zoned as mixed use agricultural.

Appears lived in, but gate locked and no people onsite.

N25° 29.450 W80° 21.817.

NNW (B) 4.7 miles 328° SFM Tree Farm. Entrance at SW 107th Ave & SW 296th St. Four people work on the property Mon-Fri 6:30-5:30. Contact is Mario.

Owner lives off property in Miami. N25° 29.564 W80° 22.264.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 23 of 54 Annual Radiological Environmental Operating Report TURKEY POINT GARDEN SURVEY RESULTS August 2020 Sector Range Bearing Nearest Garden Location (with estimated total area of 500 square feet, or more, and producing green leafy vegetables).

N No suitable gardens were located within a five-mile range.

NNE No suitable gardens were located within a five-mile range.

NE No suitable gardens were located within a five-mile range.

ENE No suitable gardens were located within a five-mile range.

E No suitable gardens were located within a five-mile range.

ESE No suitable gardens were located within a five-mile range.

SE No suitable gardens were located within a five-mile range.

SSE No suitable gardens were located within a five-mile range.

S No suitable gardens were located within a five-mile range.

SSW No suitable gardens were located within a five-mile range.

SW No suitable gardens were located within a five-mile range.

WSW No suitable gardens were located within a five-mile range.

W No suitable gardens were located within a five-mile range.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 24 of 54 Annual Radiological Environmental Operating Report TURKEY POINT GARDEN SURVEY RESULTS August 2020 (cont.)

Sector Range Bearing Nearest Garden Location (with estimated total area of 500 square feet, or more, and producing green leafy vegetables).

WNW (A) 4.5 miles 303° Thai Farms. South of Mowry Drive (SW 320th St) and about 0.6 miles west of Allapattah Rd (SW 117th Ave). Growing guava dragon fruit, papaya, palm, bamboo, and more. No one present.

Phone number on farm sign reached the previous owner who sold 3 years ago and does not know how to contact new owners.

N25° 28.217 W80° 23.467.

WNW (B) 6.0 miles 295° Farm Share, Inc at 14125 SW 320th St, where farmers donate locally grown produce to be given to charitable organizations.

Produce donations usually start in November and run through April. About 20 workers present from 8 am to 4:30 pm Monday thru Friday. The produce donated is usually tomatoes, bananas, squash, green beans, okra, corn, potatoes, watermelon and zucchini. The contact is now Nick Sanchez.

N25° 28.255 W80° 25.111.

NW No suitable gardens were located within a five-mile range.

NNW (A) 4.4 miles 332° Under the vine. 11100 SW 296th St. Entrance at SW 107th Ave &

SW 296th St just east of SFM Tree Farm. Growing only dragon fruit. Open Mon-Sat 8:00-5:00. 3 employees plus the owner work here. No onsite residents. N25° 29.464 W80° 21.828.

NNW (B) 4.7 miles 328° SFM Tree Farm. Entrance at SW 107th Ave & SW 296th St.

Noticed bananas, dragon fruit, plantain tress, coconuts and mangoes growing in various areas on the farm. Owner lives off property in Miami. Gate locked, waited 15 minutes, and did not see an employee. N25° 29.564 W80° 22.264.

Note: At the time of our survey, many fields in the area surveyed were bare soil or cover crops. Other than the sites already described above, the only non-ornamental crops known to have been grown in the survey area were: bananas, beans, corn, guava, malanga, papaya, eggplant, sorghum, squash, sugar cane, tambis, okra and melon.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 25 of 54 Annual Radiological Environmental Operating Report TURKEY POINT MILK ANIMAL SURVEY RESULTS August 2020 Sector Nearest Milk Animals (cows or goats).

N No potential milk animals were located within five miles.

NNE No potential milk animals were located within five miles.

NE No potential milk animals were located within five miles.

ENE No potential milk animals were located within five miles.

E No potential milk animals were located within five miles.

ESE No potential milk animals were located within five miles.

SE No potential milk animals were located within five miles.

SSE No potential milk animals were located within five miles.

S No potential milk animals were located within five miles.

SSW No potential milk animals were located within five miles.

SW No potential milk animals were located within five miles.

WSW No potential milk animals were located within five miles.

W No potential milk animals were located within five miles.

WNW No potential milk animals were located within five miles.

NW No potential milk animals were located within five miles.

NNW No potential milk animals were located within five miles.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 26 of 54 Annual Radiological Environmental Operating Report 4.7 Interlaboratory Comparison Results contains result summary for Interlaboratory Comparison program for the Department of Energy Mixed Analyte Performance Evaluation Program (MAPEP).

These satisfied the requirement of Control 5.3 of the ODCM for the Interlaboratory Comparison Program.

5.1 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

1.

Table 6, Radiological Environmental Monitoring Program Summary, summarizes data for the 2020 REMP program.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 27 of 54 Annual Radiological Environmental Operating Report Table 6: Radiological Environmental Monitoring Program Summary Sample Type (Units)

Type / Number of Analyses (1)

LLD (2)

Indicator Locations Mean (F)(3)

[Range]

Indicator (4)

Location [Highest Annual Mean]

Mean (F)(3)

[Range]

Control Locations Mean (F)(3) [Range]

Number of Non-Routine Results (5)

Air Particulate GB / 312 0.01 0.0123 (250 / 260)

T58 0.0129 (49 / 52) 0.0120 (51 / 52) 0

[0.0040 - 0.0290]

(1 mi. NW)

[0.0060 - 0.0290]

[0.0010 - 0.0230]

GS / 24 Be-7 0.1242 (20 / 20)

T72 0.1375 (4 / 4) 0.1242 (4 / 4) 0

[0.0738 - 0.1750]

(<1 mi. WSW)

[0.1190 - 0.1720]

[0.0926 - 0.1670]

(pCi/m3)

K-40

< LLD N/A N/A

< LLD 0

Cs-134 0.05

< LLD N/A N/A

< LLD 0

Cs-137 0.06

< LLD N/A N/A

< LLD 0

Pb-210 0.0093 (8 / 20)

T58 0.0105 (1 / 4) 0.0103 (2 / 4) 0

[0.0058 - 0.0133]

(1.3 mi. NW)

[<LLD - 0.0105]

[ 0.0082 - 0.0123]

Airborne Iodine (pCi/m3)

I-131 / 312 0.07

< LLD N/A N/A

< LLD 0

Direct Radiation Gamma / 87 (6) 3.4 (87 / 87)

NW-10 4.1 (4 / 4)

N/A 0

Indicator TLD

[2.4 - 4.7]

(10 mi. NW)

[3.8 - 4.4]

(µR/hour)

Direct Radiation Gamma / 4 (6)

N/A N/A N/A 3.7 (4 / 4) 0 Control TLD

[3.5 - 4.1]

(µR/hour)

LEGEND:

(1) - GB = Gross beta; I-131 = Iodine-131; H-3 = Tritium; GS = Gamma scan.

(2) - LLD = Required lower limit of detection based on Turkey Point ODCM.

(3) - Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parenthesis (F).

(4) - Locations are specified (1) by name and (2) direction relative to reactor site.

(5) - Non-routine results are those which exceed ten times the control station value. If no control station value is available, the result is considered non-routine if it exceeds ten times the preoperational value for the location.

(6) - LLD is not defined in Turkey Point ODCM.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 28 of 54 Annual Radiological Environmental Operating Report Table 6: Radiological Environmental Monitoring Program Summary Sample Type (Units)

Type / Number of Analyses (1)

LLD (2)

Indicator Locations Mean (F)(3)

[Range]

Indicator (4)

Location [Highest Annual Mean]

Mean (F)(3)

[Range]

Control Locations Mean (F)(3) [Range]

Number of Non-Routine Results (5)

Surface Water H-3 / 36 3,000 93 (2 / 24)

T42, T81 93 (1 / 12)

<LLD 0

[<LLD - 93]

(<1 mi. ENE)

[93]

(6 mi. S)

(pCi/L)

GS / 36 K-40 315 (24 / 24)

T81 335 (12 /12) 255 (12 / 12) 0

[146 - 475]

(6 mi. S)

[264 - 433]

[161 - 334]

Sediment GS / 6

< LLD N/A N/A

< LLD 0

Be-7 K-40 182 (3 / 4)

T67 465 (2 / 2) 465 (2 / 2) 0

[92 - 308]

(13 - 18 mi. N, NNE)

[104 - 826]

[104 - 826]

Cs-137 180

< LLD N/A N/A

< LLD 0

Pb-210 430 (2 / 4)

T67 939 (1 / 2) 939 (1 / 2) 0

[393 - 466]

(13 - 18 mi. N, NNE)

[939]

[<LLD - 939]

Ra-226 546 (4 / 4)

T67 1370 (1 / 2) 1370 (1 / 2) 0 (pCi/kg dry)

[466 - 681]

(13 - 18 mi. N, NNE)

[1370]

[<LLD - 1370]

Th-232

<LLD T67 245 (1 / 2) 245 (1 / 2) 0 (13 - 18 mi. N, NNE)

[245]

[<LLD - 245]

U-235 52 (4 / 4)

T67 182 (1 / 2) 182 (1 / 2) 0

[29 - 74]

(13 - 18 mi. N, NNE)

[182]

[<LLD - 182]

U-238 319 (4 / 4)

T67 820 (1 / 2) 820 (1 / 2) 0

[247 - 467]

(13 - 18 mi. N, NNE)

[820]

[<LLD - 820]

LEGEND:

(1) - GB = Gross beta; I-131 = Iodine-131; H-3 = Tritium; GS = Gamma scan.

(2) - LLD = Required lower limit of detection based on Turkey Point ODCM.

(3) - Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parenthesis (F).

(4) - Locations are specified (1) by name and (2) direction relative to reactor site.

(5) - Non-routine results are those which exceed ten times the control station value. If no control station value is available, the result is considered non-routine if it exceeds ten times the preoperational value for the location.

(6) - LLD is not defined in Turkey Point ODCM.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 29 of 54 Annual Radiological Environmental Operating Report Table 6: Radiological Environmental Monitoring Program Summary Sample Type (Units)

Type / Number of Analyses (1)

LLD (2)

Indicator Locations Mean (F)(3)

[Range]

Indicator (4)

Location [Highest Annual Mean]

Mean (F)(3)

[Range]

Control Locations Mean (F)(3) [Range]

Number of Non-Routine Results (5)

Crustacea GS / 4 1525 (2 / 2)

[1400 - 1650]

T81 (6 mi. S) 1525 (2 / 2)

[1400 - 1650]

1415 (2 / 2)

[1350 - 1480]

0 K-40 (pCi/kg wet)

Ra-226 706 (1 / 2)

[<LLD - 706]

T81 (6 mi. S) 706 (1 / 2)

[<LLD - 706]

370 (1 / 2)

[<LLD - 370]

0 Ra-228

<LLD N/A N/A

<LLD 0

Fish (pCi/kg wet)

GS / 4 3120 (2 / 2)

[2900 - 3340]

< LLD T81 (6 mi. S)

N/A 3120 (2 / 2)

[2900 - 3340]

N/A 2190 (2 / 2)

[2020 - 2360]

< LLD 0

0 K-40 Ra-226 Ra-228

< LLD N/A N/A

< LLD 0

Broad Leaf GS / 36 1890 (24 / 24)

T40 2135 (12 / 12) 1514 (12 / 24) 0 Be-7

[998 - 3650]

(3 mi. W / WNW)

[998 - 3650]

[723 - 2290]

K-40 4254 (24 / 24)

T41 4358 (12 / 12) 4068 (12 / 12) 0

[2280 - 5530]

(1.6 mi. WNW)

[2890 - 5530]

[1860 - 5720]

Cs-137 80 125 (11 / 24)

T41 289 (4 / 12) 16 (3 / 12) 0 (pCi/kg wet)

[6 - 981]

(1.6 mi. WNW)

[6 - 981]

[10 - 27]

Pb-210 634 (6 / 24)

T41 724 (2 / 12) 296 (5 / 12) 0

[209 - 1239]

(1.6 mi. WNW)

[209 - 1239]

[182 - 370]

Pb-212 16 (1 / 24)

T67 23 (1 / 12) 23 (1 / 12) 0

[16]

13 - 18 mi. N, NNE)

[<LLD - 23]

[<LLD - 23]

Ra-226 193 (2 / 24)

T40 256 (1 / 12) 32 (1 / 12) 0

[129 - 256]

(3 mi. W / WNW)

[<LLD - 256]

[<LLD - 32]

LEGEND:

(1) - GB = Gross beta; I-131 = Iodine-131; H-3 = Tritium; GS = Gamma scan.

(2) - LLD = Required lower limit of detection based on Turkey Point ODCM.

(3) - Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parenthesis (F).

(4) - Locations are specified (1) by name and (2) direction relative to reactor site.

(5) - Non-routine results are those which exceed ten times the control station value. If no control station value is available, the result is considered non-routine if it exceeds ten times the preoperational value for the location.

(6) - LLD is not defined in Turkey Point ODCM.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 30 of 54 Annual Radiological Environmental Operating Report Page 1 of 1 Sample Deviations Table 7: Sample Deviations Table Comment No.

Sample Media Affected Sample Location Date Problem Evaluation / Actions 1

Air Sample T-41 06/24/20 Faulty Equipment Low pump flow & unable to adjust flowrate. Unable to adjust flowrate due to valve being at maximum stroke. Replaced pump and flow meter. Flow adjusted and continuous sampling restored. Condition Report (AR) # 02389161 2

Air Sample T-41 07/07/20 Faulty Equipment Found in-line flow meter obstructed. Identified and replaced the obstructed in-line flow meter. AR# 02389161 3

Air Sample T-56 11/04/20 Data record Error Collection time not recorded on 11/4/20. An estimated time based on reading of 539,100 at 12:05 on 11/09/20 was recorded. AR# 02389161 4

Milk T-99 11/30/20 Sample Unavailable Goat milk sample was unavailable this year. The farm has not had any milking goats. AR# 02389161 5

Direct Radiation SSW-10 12/10/20 Sample Missing TLD & cricket cage missing. Replaced cage & deployed new TLD. AR# 02389161 6

Air Sample T-52 12/16/20 Pump Failure Pump ran for 2 hrs. on 12/16/20, then removed to replace failed pump at T58.

Pump replaced on 12/17/20 & time interval adjusted to include runtime from 12/16/20. AR# 02389161 7

Air Sample T-58 12/16/20 Pump Failure Pump failed, estimated run time 101 out of 165 hours0.00191 days <br />0.0458 hours <br />2.728175e-4 weeks <br />6.27825e-5 months <br />. T-58 pump failed and replaced with T-52 pump on 12/16/20. AR# 02389161 8

Air Sample T-64 12/16/20 Pump Failure Pump failed, estimated run time 78 out of 187 hours0.00216 days <br />0.0519 hours <br />3.091931e-4 weeks <br />7.11535e-5 months <br />. Pump failed and replace with pump from T-56 on 12/16/20. AR# 02389161 9

Air Sample T-56 12/16/20 Power Outage T-56 had no vacuum pump for approximately one day. The pump was removed from service to replace the failing pump at T-64. A new pump was installed at this location on 12/17/20. AR# 02389161

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 31 of 54 Annual Radiological Environmental Operating Report ATTACHMENT 2 Monitoring Results Tables RADIOLOGICAL SURVEILLANCE OF FLORIDA POWER AND LIGHT COMPANY'S TURKEY POINT SITE 2020 First Quarter, 2020 Second Quarter, 2020 Third Quarter, 2020 Fourth Quarter, 2020

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 32 of 54 Annual Radiological Environmental Operating Report Monitoring Results Tables Table 8: Air Particulate - Gross Beta Page 1 of 16 Analysis: Gross Beta Units: pCi/m3 End Date T41 (Indicator)

T51 (Indicator)

T57 (Indicator)

T58(1)

(Indicator)

T64 (Control)

T72 (Indicator)

LLD 0.01 0.01 0.01 0.01 0.01 0.01 01/07/2020 0.014 0.015 0.017 0.021 0.022 0.017 01/15/2020 0.014 0.009 0.013 0.012 0.014 0.011 01/21/2020 0.013 0.013 0.014 0.013 0.014 0.016 01/28/2020 0.013 0.013 0.011 0.012 0.016 0.013 02/05/2020 0.010 0.011 0.017 0.016 0.013 0.017 02/12/2020 0.014 0.016 0.014 0.013 0.015 0.011 02/19/2020 0.007 0.009 0.009 0.012 0.010 0.009 02/25/2020 0.005 0.005 0.004 0.006 0.004

<0.009 03/03/2020 0.010 0.014 0.013 0.014 0.013 0.009 03/10/2020 0.009 0.009 0.009 0.010 0.008 0.012 03/18/2020 0.010 0.012 0.008 0.010 0.008 0.012 03/25/2020 0.009 0.012 0.008 0.017 0.012 0.008 04/01/2020 0.007 0.011 0.010 0.008 0.010 0.009 04/08/2020 0.022 0.019 0.024 0.029 0.023 0.019 04/13/2020 0.018 0.025 0.025 0.026 0.021 0.019 04/22/2020 0.014 0.015 0.019 0.016 0.017 0.015 04/29/2020 0.010 0.020 0.016 0.017 0.014 0.015 05/06/2020 0.018 0.018 0.018 0.016 0.018 0.017 05/13/2020 0.016 0.016 0.015 0.016 0.018 0.015 05/18/2020 0.012 0.011 0.009 0.012 0.012 0.008 05/27/2020 0.013 0.012 0.013 0.015 0.014 0.017 06/03/2020 0.008 0.009 0.011 0.008 0.007 0.012 06/10/2020 0.010 0.009 0.011 0.014 0.011 0.010 06/17/2020 0.013 0.012 0.008 0.007 0.009 0.009 06/24/2020 0.010 0.008 0.006 0.009 0.006 0.005 06/30/2020 0.009 0.012 0.011 0.011 0.012 0.012 07/07/2020 0.008 0.012 0.007 0.011 0.016 0.011 07/13/2020 0.020 0.024 0.017 0.020 0.018 0.020 07/21/2020 0.011 0.011 0.012 0.011 0.013 0.013 07/27/2020 0.005 0.010 0.007 0.006 0.005 0.008 08/04/2020 0.013 0.013 0.011 0.015 0.013 0.014 08/11/2020 0.009 0.010 0.012 0.010 0.006 0.010 08/17/2020 0.012 0.012 0.014 0.007 0.011 0.016 08/26/2020 0.014 0.010 0.013 0.012 0.012 0.011 09/01/2020 0.011 0.010 0.007 0.006 0.008 0.012 09/08/2020 0.018 0.022 0.018 0.017 0.016 0.015 09/14/2020

<0.009 0.006

<0.009

<0.009 0.008 0.004 09/22/2020 0.007 0.007 0.009 0.006 0.006 0.010 09/29/2020 0.006 0.007 0.006 0.008 0.007 0.009 10/06/2020 0.010 0.011 0.010 0.007 0.010 0.010 10/12/2020 0.013 0.008 0.009 0.010 0.007 0.012 10/19/2020 0.009 0.010 0.009 0.011 0.008 0.009 10/26/2020 0.008 0.005 0.008 0.007 0.001 0.005 11/04/2020 0.013 0.011 0.014 0.006 0.015 0.012 11/10/2020 0.007 0.005

<0.011

<0.009 0.004 0.004 11/19/2020 0.012 0.012 0.010 0.012 0.009 0.011 11/25/2020 0.004

<0.008

<0.008

<0.007

<0.008

<0.007 12/02/2020 0.010 0.013 0.012 0.016 0.013 0.010 12/09/2020 0.019 0.019 0.011 0.016 0.018 0.019 12/16/2020 0.014 0.019 0.016 0.024 0.022 0.017 12/23/2020 0.017 0.021 0.019 0.020 0.016 0.020 12/29/2020 0.015 0.014 0.013 0.013 0.010 0.013 (1) Station with highest annual mean.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 33 of 54 Annual Radiological Environmental Operating Report Monitoring Results Tables Table 9: Air Particulate Composite - Gamma Page 2 of 16 Analysis: Gamma Isotopic Units: pCi/m3 Location Collection Date Be-7 K-40 Cs-134 Cs-137 Pb-210 REQUIRED LLD 0.05 0.06 T41 (Indicator) 03/25/2020 0.1260

<0.0129

<0.0012

<0.0008

<0.0141 T51 (Indicator) 03/25/2020 0.1280

<0.0201

<0.0011

<0.0009

<0.0282 T57 (Indicator) 03/25/2020 0.1180

<0.0134

<0.0012

<0.0009

<0.0147 T58 (Indicator) 03/25/2020 0.1050

<0.0209

<0.0011

<0.0009

<0.0344 T64 (Control) 03/25/2020 0.1060

<0.0156

<0.0010

<0.0010

<0.0148 T72 (Indicator) 03/25/2020 0.1190

<0.0157

<0.0011

<0.0009

<0.0253 T41 (Indicator) 06/30/2020 0.1300

<0.0189

<0.0009

<0.0008 0.0133 T51 (Indicator) 06/30/2020 0.1220

<0.0142

<0.0012

<0.0010 0.0107 T57 (Indicator) 06/30/2020 0.1370

<0.0128

<0.0012

<0.0011

<0.0154 T58 (Indicator) 06/30/2020 0.1240

<0.0183

<0.0011

<0.0012

<0.0303 T64 (Control) 06/30/2020 0.1310

<0.0196

<0.0009

<0.0006 0.0123 T72 (Indicator) 06/30/2020 0.1390

<0.0127

<0.0012

<0.0009

<0.0154 T41 (Indicator) 09/29/2020 0.0738

<0.0134

<0.0011

<0.0008 0.0058 T51 (Indicator) 09/29/2020 0.0939

<0.0218

<0.0008

<0.0007 0.0086 T57 (Indicator) 09/29/2020 0.0949

<0.0223

<0.0013

<0.0010 0.0058 T58 (Indicator) 09/29/2020 0.0845

<0.0131

<0.0014

<0.0011

<0.0155 T64 (Control) 09/29/2020 0.0926

<0.0197

<0.0010

<0.0006 0.0082 T72 (Indicator) 09/29/2020 0.1200

<0.0208

<0.0011

<0.0009

<0.0088 T41 (Indicator) 12/29/2020 0.1440

<0.0172

<0.0010

<0.0009 0.0079 T51 (Indicator) 12/29/2020 0.1750

<0.0134

<0.0016

<0.0012

<0.0155 T57 (Indicator) 12/29/2020 0.1440

<0.0179

<0.0008

<0.0008 0.0115 T58 (Indicator) 12/29/2020 0.1340

<0.0142

<0.0015

<0.0011 0.0105 T64 (Control) 12/29/2020 0.1670

<0.0211

<0.0010

<0.0009

<0.0105 T72 (Indicator) 12/29/2020 0.1720

<0.0158

<0.0013

<0.0010

<0.0155

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 34 of 54 Annual Radiological Environmental Operating Report Page 3 of 16 Monitoring Results Tables Table 10: Air Cartridges - Iodine-131 Analysis: Gross Beta Units: pCi/m3 End Date T41 (Indicator)

T51 (Indicator)

T57 (Indicator)

T58 (Indicator)

T64 (Control)

T72 (Indicator)

LLD 0.07 0.07 0.07 0.07 0.07 0.07 01/07/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 01/15/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 01/21/2020

<0.03

<0.02

<0.02

<0.03

<0.02

<0.02 01/28/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 02/05/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 02/12/2020

<0.02

<0.01

<0.01

<0.01

<0.01

<0.01 02/19/2020

<0.02

<0.01

<0.01

<0.02

<0.02

<0.01 02/25/2020

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 03/03/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 03/10/2020

<0.03

<0.02

<0.02

<0.02

<0.02

<0.02 03/18/2020

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 03/25/2020

<0.03

<0.02

<0.02

<0.03

<0.02

<0.02 04/01/2020

<0.02

<0.01

<0.01

<0.02

<0.01

<0.01 04/08/2020

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 04/13/2020

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 04/22/2020

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 04/29/2020

<0.02

<0.01

<0.02

<0.02

<0.01

<0.02 05/06/2020

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 05/13/2020

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 05/18/2020

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 05/27/2020

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 06/03/2020

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 06/10/2020

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 06/17/2020

<0.02

<0.01

<0.01

<0.01

<0.02

<0.01 06/24/2020

<0.02

<0.02

<0.01

<0.01

<0.01

<0.01 06/30/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 07/07/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 07/13/2020

<0.01

<0.02

<0.02

<0.02

<0.02

<0.02 07/21/2020

<0.01

<0.02

<0.01

<0.02

<0.02

<0.01 07/27/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 08/04/2020

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 08/11/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 08/17/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 08/26/2020

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 09/01/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 09/08/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 09/14/2020

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 09/22/2020

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 09/29/2020

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 10/06/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 10/12/2020

<0.03

<0.03

<0.03

<0.03

<0.02

<0.03 10/19/2020

<0.02

<0.03

<0.03

<0.02

<0.03

<0.02 10/26/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 11/04/2020

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 11/10/2020

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 11/19/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 11/25/2020

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 12/02/2020

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 12/09/2020

<0.01

<0.02

<0.02

<0.01

<0.02

<0.02 12/16/2020

<0.02

<0.02

<0.02

<0.03

<0.04

<0.02 12/23/2020

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 12/29/2020

<0.04

<0.04

<0.04

<0.04

<0.04

<0.04

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 35 of 54 Annual Radiological Environmental Operating Report Page 4 of 16 Monitoring Results Tables Table 11: Direct Radiation-Indicators (1) Indicator station with highest annual mean.

(2) See Sample Deviations Table.

Table 12: Direct Radiation - Control Analysis: Gamma Dose Units: mrem/Hr Station 1st Qtr 2020 2nd Qtr 2020 3rd Qtr 2020 4th Qtr 2020 Annual Mean 2020 NNE-22 3.6 3.8 4.1 3.5

3.7 Analysis

Gamma Dose Units: mrem/hr Station 1st Qtr 2020 2nd Qtr 2020 3rd Qtr 2020 4th Qtr 2020 Annual Mean 2020 N-2 3.9 4.0 4.7 3.6 4.0 N-7 3.1 3.3 3.8 2.9 3.3 N-10 3.5 3.6 4.3 3.5 3.7 NNW-2 3.4 3.7 3.7 3.3 3.5 NNW-10 3.3 3.8 4.0 3.3 3.6 NW-1 3.7 3.9 4.4 3.5 3.8 NW-5 2.9 3.3 3.7 3.0 3.2 NW-10(1) 4.0 4.4 4.4 3.8 4.1 WNW-2 3.0 3.5 3.7 3.2 3.4 WNW-10 4.1 4.3 4.4 3.5 4.0 W-1 4.0 3.9 4.1 3.6 3.9 W-5 3.2 3.7 4.1 3.2 3.5 W-9 2.6 3.2 3.6 2.8 3.1 WSW-8 3.3 3.4 3.4 3.0 3.3 SW-1 3.9 3.7 3.7 3.1 3.6 SW-8 2.9 2.9 3.1 2.5 2.8 SSW-5 2.7 3.0 3.2 2.7 2.9 SSW-10 3.4 3.3 3.6 (2) 3.4 S-5 2.9 3.0 3.1 2.6 2.9 S-10 3.7 3.5 3.8 3.1 3.5 SSE-1 2.9 2.9 3.0 2.4 2.8 SSE-10 3.0 3.1 3.0 2.8

3.0 Plant

Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 36 of 54 Annual Radiological Environmental Operating Report Monitoring Results Tables Table 13: Surface Water - Tritium and Gamma Page 5 of 16 Analysis: Gamma Isotopic Units: pCi/L Location End Date H-3 K-40 Location End Date H-3 K-40 Location End Date H-3 K-40 REQUIRED LLD 3,000 REQUIRED LLD 3,000 REQUIRED LLD 3,000 T42 (Indicator) 01/07/2020

<140 230 T67 (Control) 01/06/2020

<138 219 T81 (Indicator) 01/07/2020

<140 398 T42 (Indicator) 02/05/2020

<146 269 T67 (Control) 02/04/2020

<146 220 T81 (Indicator) 02/05/2020

<138 277 T42 (Indicator) 03/11/2020

<141 287 T67 (Control) 03/10/2020

<141 304 T81 (Indicator) 03/11/2020

<141 308 T42 (Indicator) 04/10/2020 93 475 T67 (Control) 04/10/2020

<136 334 T81 (Indicator) 04/10/2020

<138 433 T42 (Indicator) 05/15/2020

<151 435 T67 (Control) 05/19/2020

<144 186 T81 (Indicator) 05/15/2020

<144 420 T42 (Indicator) 06/16/2020

<137 310 T67 (Control) 06/17/2020

<137 231 T81 (Indicator) 06/16/2020

<137 311 T42 (Indicator) 07/10/2020

<139 335 T67 (Control) 07/13/2020

<139 277 T81 (Indicator) 07/10/2020

<139 381 T42 (Indicator) 08/14/2020

<142 372 T67 (Control) 08/17/2020

<141 265 T81 (Indicator) 08/14/2020

<139 332 T42 (Indicator) 09/11/2020

<139 245 T67 (Control) 09/14/2020

<139 161 T81 (Indicator) 09/11/2020

<139 310 T42 (Indicator) 10/09/2020

<134 280 T67 (Control) 10/12/2020

<134 226 T81 (Indicator) 10/09/2020 93 323 T42 (Indicator) 11/24/2020

<139 160 T67 (Control) 11/25/2020

<139 333 T81 (Indicator) 11/24/2020

<139 264 T42 (Indicator) 12/10/2020

<139 146 T67 (Control) 12/08/2020

<139 299 T81 (Indicator) 12/10/2020

<139 265

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 37 of 54 Annual Radiological Environmental Operating Report Page 6 of 16 Monitoring Results Tables Table 14: Shoreline Sediment - Gamma Analysis: Gamma Isotopic Units: pCi/kg (dry)

Location Collection Date Be-7 K-40 Cs-137 Pb-210 Ra-226 Th-232 U-235 U-238 REQUIRED LLD 180 T42 (Indicator) 01/07/2020

<120 92

<11

<1100 556

<49 73 287 T67 (Control) 01/06/2020

<143 826

<13 939 1370 245 182 820 T81 (Indicator) 01/07/2020

<128 308

<11

<1120 681

<52 74 467 T42 (Indicator) 07/10/2020

<110 147

<9 393 466

<39 29 276 T67 (Control) 07/13/2020

<63 104

<5

<292

<183

<26

<12

<86 T81 (Indicator) 07/10/2020

<110

<148

<8 466 481

<38 30 247

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 38 of 54 Annual Radiological Environmental Operating Report Page 7 of 16 Monitoring Results Tables Table 15: Crustacea - Gamma Analysis: Gamma Isotopic Units: pCi/kg (wet)

Location Collection Date Sample Type K-40 Ra-226 Ra-228 REQUIRED LLD T67 (Control) 03/11/2020 Blue Crab 1480

<64

<102 T81 (Indicator) 05/18/2020 Blue Crab 1650

<346

<82 T67 (Control) 10/22/2020 Blue Crab 1350 370

<110 T81 (Indicator) 10/21/2020 Blue Crab 1400 706

<83

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 39 of 54 Annual Radiological Environmental Operating Report Page 8 of 16 Monitoring Results Tables Table 16: Fish - Gamma Analysis: Gamma Isotopic Units: pCi/kg (wet)

Location Collection Date Sample Type K-40 Ra-226 Ra-228 REQUIRED LLD T67 (Control) 03/10/2020 Mixed Species 2020

<44

<73 T81 (Indicator) 03/11/2020 Mixed Species 2900

<51

<96 T67 (Control) 10/21/2020 Mixed Species 2360

<308

<55 T81 (Indicator) 10/15/2020 Mixed Species 3340

<419

<89

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 40 of 54 Annual Radiological Environmental Operating Report Page 9 of 16 Monitoring Results Tables Table 17: Broad Leaf Vegetation - Gamma Analysis: Gamma Isotopic Units: pCi/kg (wet)

Location Collection Date Sample Type Be-7 K-40 Cs-137 Pb-210 Pb-212 Ra-226 REQUIRED LLD 80 T40 (Indicator) 01/07/2020 Brazilian Pepper 2300 3690 9

423

<19

<22 T40 (Indicator) 02/05/2020 Brazilian Pepper 3650 4330

<21

<1380

<28

<33 T40 (Indicator) 03/10/2020 Brazilian Pepper 1680 3310 62 877

<24

<33 T40 (Indicator) 04/10/2020 Brazilian Pepper 998 3218

<20

<1034

<28 256 T40 (Indicator) 05/15/2020 Brazilian Pepper 1070 2280

<16

<729 16

<277 T40 (Indicator) 06/17/2020 Brazilian Pepper 2260 5290

<16 764

<24

<298 T40 (Indicator) 07/13/2020 Brazilian Pepper 2320 4950 18

<294

<21

<259 T40 (Indicator) 08/17/2020 Brazilian Pepper 2070 4120 25

<603

<18

<229 T40 (Indicator) 09/14/2020 Brazilian Pepper 1930 4860 78

<301

<23

<263 T40 (Indicator) 10/12/2020 Brazilian Pepper 1660 5190 11

<283

<22

<251 T40 (Indicator) 11/24/2020 Brazilian Pepper 2200 3470 17 289

<18

<202 T40 (Indicator) 12/09/2020 Brazilian Pepper 3480 5090

<17

<942

<26

<301 T41(Indicator) 01/07/2020 Brazilian Pepper 1210 5030

<17

<906

<26

<33 T41(Indicator) 02/05/2020 Brazilian Pepper 1860 5010

<20

<1380

<29

<30 T41(Indicator) 03/10/2020 Brazilian Pepper 1870 4580

<13

<853

<22

<29 T41(Indicator) 04/10/2020 Brazilian Pepper 1260 4620

<17 1239

<29

<349 T41(Indicator) 05/15/2020 Brazilian Pepper 1140 3800 17

<867

<20

<309 T41(Indicator) 06/17/2020 Brazilian Pepper 1430 3940 6

209

<19

<231 T41(Indicator) 07/13/2020 Brazilian Pepper 1010 4870 981

<959

<28

<429 T41(Indicator) 08/17/2020 Brazilian Pepper 1980 5530

<11

<290

<21 129 T41(Indicator) 09/14/2020 Brazilian Pepper 1950 2890 150

<708

<20

<247 T41(Indicator) 10/12/2020 Brazilian Pepper 2150 4330

<10

<625

<18

<227 T41(Indicator) 11/24/2020 Brazilian Pepper 2370 4230

<12

<678

<18

<241 T41(Indicator) 12/10/2020 Brazilian Pepper 1520 3470

<11

<246

<18

<238 T67 (Control) 01/07/2020 Brazilian Pepper 1780 4820

<18

<1130

<27

<33 T67 (Control) 03/04/2020 Brazilian Pepper 1340 5200

<11

<1020

<22 32 T67 (Control) 03/10/2020 Brazilian Pepper 1190 4990

<18

<1050

<27

<32 T67 (Control) 04/10/2020 Brazilian Pepper 1060 4160

<17

<1060

<24

<359 T67 (Control) 05/19/2020 Brazilian Pepper 723 1860

<12

<766 23

<222 T67 (Control) 06/17/2020 Brazilian Pepper 1600 4460

<11 316

<20

<221 T67 (Control) 07/13/2020 Brazilian Pepper 2290 3850

<12 370

<20

<230 T67 (Control) 08/17/2020 Brazilian Pepper 1850 3700 12 356

<18

<208 T67 (Control) 09/14/2020 Brazilian Pepper 1650 2950 27 182

<20

<233 T67 (Control) 10/12/2020 Brazilian Pepper 2000 5720 10 255

<23

<264 T67 (Control) 11/25/2020 Brazilian Pepper 1650 2630

<12

<561

<16

<201 T67 (Control) 12/08/2020 Brazilian Pepper 1040 4470

<13

<684

<21

<231

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 41 of 54 Annual Radiological Environmental Operating Report Page 10 of 16 Monitoring Results Tables Table 18: Supplemental Direct Radiation-Indicators Analysis: Gamma Dose Units: mrem/hr Station 1st Qtr 2020 2nd Qtr 2020 3rd Qtr 2020 4th Qtr 2020 Annual Mean 2020 NNW-6 3.2 3.5 3.7 3.2 3.4 NW-7(1) 3.9 4.0 4.1 3.6 3.9 NW-8 3.5 4.1 4.1 3.4 3.8 WNW-3 3.1 3.5 3.6 3.2 3.4 WNW-6 3.2 3.4 3.5 3.0 3.3 W-8 3.5 3.8 4.1 3.4 3.7 ENE-1 3.0 2.9 3.1 2.3 2.8 T72 3.3 3.5 3.8 3.2 3.5 PTN-1 3.2 3.5 3.4 3.2 3.3 (1) Indicator station with highest annual mean.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 42 of 54 Annual Radiological Environmental Operating Report Page 11 of 16 Monitoring Results Tables Table 19: Supplemental Air Particulate - Gross Beta Analysis: Gross Beta Units: pCi/m 3

End Date T52 (Indicator)

T56(1) (Indicator)

LLD 0.01 0.01 01/07/2020 0.018 0.015 01/15/2020 0.014 0.013 01/21/2020 0.010 0.013 01/28/2020 0.012 0.015 02/05/2020 0.014 0.013 02/12/2020 0.016 0.010 02/19/2020 0.005 0.008 02/25/2020

<0.009 0.007 03/03/2020 0.010 0.012 03/10/2020 0.009 0.011 03/18/2020 0.004 0.009 03/25/2020 0.007 0.007 04/01/2020 0.011 0.012 04/08/2020 0.023 0.020 04/13/2020 0.027 0.022 04/22/2020 0.015 0.017 04/29/2020 0.015 0.016 05/06/2020 0.014 0.011 05/13/2020 0.017 0.016 05/18/2020 0.009 0.008 05/27/2020 0.015 0.015 06/03/2020 0.010 0.010 06/10/2020 0.004 0.013 06/17/2020 0.011 0.009 06/24/2020 0.008 0.007 06/30/2020 0.009 0.012 07/07/2020 0.012 0.010 07/13/2020 0.021 0.022 07/21/2020 0.012 0.017 07/27/2020 0.005 0.006 08/04/2020 0.010 0.013 08/11/2020 0.010 0.009 08/17/2020 0.009 0.009 08/26/2020 0.012 0.011 09/01/2020 0.007 0.011 09/08/2020 0.019 0.016 09/14/2020

<0.010 0.007 09/22/2020 0.009 0.007 09/29/2020 0.008 0.009 10/06/2020 0.011 0.007 10/12/2020 0.008 0.011 10/19/2020 0.013 0.012 10/26/2020 0.007 0.007 11/04/2020 0.010 0.019 11/10/2020

<0.009 0.004 11/19/2020 0.012 0.009 11/25/2020

<0.007

<0.008 12/02/2020 0.015 0.018 12/09/2020 0.017 0.019 12/16/2020 0.017 0.016 12/23/2020 0.018 0.020 12/29/2020 0.012 0.013 (1) Station with highest annual mean.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 43 of 54 Annual Radiological Environmental Operating Report Page 12 of 16 Monitoring Results Tables Table 20: Supplemental Air Particulate Composite - Gamma Analysis: Gamma Isotopic Units: pCi/m3 Location Collection Date Be-7 K-40 Cs-134 Cs-137 Pb-210 REQUIRED LLD 0.05 0.06 T52 (Indicator) 03/25/2020 0.1090

<0.0132

<0.0013

<0.0008 0.014 T56 (Indicator) 03/25/2020 0.1320

<0.0213

<0.0012

<0.0009

<0.0343 T52 (Indicator) 06/30/2020 0.1390

<0.0215

<0.0010

<0.0010

<0.0317 T56 (Indicator) 06/30/2020 0.1090

<0.0170

<0.0009

<0.0006

<0.0097 T52 (Indicator) 09/29/2020 0.1070

<0.0228

<0.0014

<0.0010

<0.0096 T56 (Indicator) 09/29/2020 0.0937

<0.0173

<0.0008

<0.0007

<0.0094 T52 (Indicator) 12/29/2020 0.1550

<0.0155

<0.0010

<0.0008

<0.0100 T56 (Indicator) 12/29/2020 0.1920

<0.0157

<0.0012

<0.0010 0.0131

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 44 of 54 Annual Radiological Environmental Operating Report Page 13 of 16 Monitoring Results Tables Table 21: Supplemental Air Cartridges - Iodine-131 Analysis: Gross Beta Units: pCi/m 3

End Date T52 (Indicator)

T56(1) (Indicator)

LLD 0.07 0.07 01/07/2020

<0.02

<0.02 01/15/2020

<0.02

<0.02 01/21/2020

<0.02

<0.03 01/28/2020

<0.02

<0.02 02/05/2020

<0.02

<0.02 02/12/2020

<0.02

<0.01 02/19/2020

<0.01

<0.02 02/25/2020

<0.03

<0.03 03/03/2020

<0.02

<0.02 03/10/2020

<0.02

<0.02 03/18/2020

<0.01

<0.01 03/25/2020

<0.02

<0.02 04/01/2020

<0.01

<0.01 04/08/2020

<0.04

<0.03 04/13/2020

<0.03

<0.03 04/22/2020

<0.03

<0.03 04/29/2020

<0.02

<0.01 05/06/2020

<0.03

<0.03 05/13/2020

<0.03

<0.03 05/18/2020

<0.03

<0.03 05/27/2020

<0.02

<0.01 06/03/2020

<0.01

<0.03 06/10/2020

<0.03

<0.03 06/17/2020

<0.03

<0.01 06/24/2020

<0.01

<0.01 06/30/2020

<0.02

<0.02 07/07/2020

<0.01

<0.02 07/13/2020

<0.02

<0.02 07/21/2020

<0.02

<0.02 07/27/2020

<0.02

<0.02 08/04/2020

<0.01

<0.01 08/11/2020

<0.02

<0.02 08/17/2020

<0.02

<0.02 08/26/2020

<0.01

<0.01 09/01/2020

<0.02

<0.02 09/08/2020

<0.02

<0.02 09/14/2020

<0.03

<0.03 09/22/2020

<0.01

<0.01 09/29/2020

<0.03

<0.03 10/06/2020

<0.02

<0.02 10/12/2020

<0.03

<0.03 10/19/2020

<0.02

<0.03 10/26/2020

<0.02

<0.02 11/04/2020

<0.01

<0.01 11/10/2020

<0.03

<0.03 11/19/2020

<0.02

<0.02 11/25/2020

<0.03

<0.03 12/02/2020

<0.02

<0.02 12/09/2020

<0.02

<0.02 12/16/2020

<0.02

<0.02 12/23/2020

<0.02

<0.02 12/29/2020

<0.04

<0.04

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 45 of 54 Annual Radiological Environmental Operating Report Page 14 of 16 Monitoring Results Tables Table 22: Supplemental Surface Water - Tritium and Gamma Analysis: Gamma Isotopic Units: pCi/L Location End Date H-3 K-40 Location End Date H-3 K-40 Location End Date H-3 K-40 Location End Date H-3 K-40 REQUIRED LLD 3,000 REQUIRED LLD 3,000 REQUIRED LLD 3,000 REQUIRED LLD 3,000 T08 (Indicator) 01/07/2020 13455 585 T75 (Indicator) 01/07/2020

<140

<41 T84 (Indicator) 01/07/2020 12468 586 T97 (Indicator) 01/07/2020 12537 584 T08 (Indicator) 02/05/2020 10571 569 T75 (Indicator) 02/05/2020

<146

<38 T84 (Indicator) 02/05/2020 11034 573 T97 (Indicator) 02/05/2020 10727 654 T08 (Indicator) 03/11/2020 12904 619 T75 (Indicator) 03/09/2020

<141

<86 T84 (Indicator) 03/10/2020 14945 682 T97 (Indicator) 03/11/2020 13820 671 T08 (Indicator) 04/10/2020 27529 686 T75 (Indicator) 04/10/2020

<136

<45 T84 (Indicator) 04/10/2020 27099 646 T97 (Indicator) 04/10/2020 25519 738 T08 (Indicator) 05/15/2020 13349 650 T75 (Indicator) 05/15/2020

<144

<88 T84 (Indicator) 05/15/2020 12953 598 T97 (Indicator) 05/15/2020 12759 619 T08 (Indicator) 06/16/2020 5456 499 T75 (Indicator) 06/17/2020

<137

<42 T84 (Indicator) 06/17/2020 5584 560 T97 (Indicator) 06/16/2020 5959 437 T08 (Indicator) 07/10/2020 3809 456 T75 (Indicator) 07/13/2020

<139

<78 T84 (Indicator) 07/10/2020 3525 454 T97 (Indicator) 07/10/2020 3438 454 T08 (Indicator) 08/14/2020 3020 439 T75 (Indicator) 08/14/2020

<139

<58 T84 (Indicator) 08/14/2020 3535 413 T97 (Indicator) 08/14/2020 3496 413 T08 (Indicator) 09/11/2020 3553 487 T75 (Indicator) 09/14/2020

<139

<32 T84 (Indicator) 09/11/2020 3926 421 T97 (Indicator) 09/11/2020 4017 421 T08 (Indicator) 10/09/2020 7343 359 T75 (Indicator) 10/09/2020

<134

<71 T84 (Indicator) 10/09/2020 8129 334 T97 (Indicator) 10/09/2020 8114 372 T08 (Indicator) 11/24/2020 5318 349 T75 (Indicator) 11/24/2020

<139

<69 T84 (Indicator) 11/25/2020 5296 286 T97 (Indicator) 11/24/2020 5230 310 T08 (Indicator) 12/10/2020 5112 385 T75 (Indicator) 12/10/2020

<139

<61 T84 (Indicator) 12/10/2020 5051 290 T97 (Indicator) 12/10/2020 4826 315

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 46 of 54 Annual Radiological Environmental Operating Report Page 15 of 16 Monitoring Results Tables Table 23: Supplemental Shoreline Sediment - Gamma Analysis: Gamma Isotopic Units: pCi/kg (dry)

Location Collection Date Be-7 K-40 Cs-137 Pb-210 Ra-226 Th-232 U-235 U-238 REQUIRED LLD 180 T01 (Indicator) 01/07/2020

<145 494

<12 805 797

<57 86 193 T02 (Indicator) 01/07/2020

<154 814 12

<1380 851

<80 111 339 T03 (Indicator) 01/07/2020

<257 2940 110 4660 2620 215 266 974 T04 (Indicator) 01/07/2020 619 681 11 1100 769

<59 81 492 T07 (Indicator) 01/07/2020

<129 578 24 673 846

<60 64 278 T08 (Indicator) 01/07/2020

<133 912 15 1100 788 61 96 319 T10 (Indicator) 01/07/2020

<199 871

<20

<1660 760

<90

<29

<325 T84* (Indicator) 01/07/2020 71 599

<15 2140 1510 61 146 503 T85* (Indicator) 01/07/2020

<133 690

<11 863 996 65 113 696 T84* (Indicator) 07/10/2020

<148 531

<13 2420 1370

<67 86 173 T85* (Indicator) 07/10/2020

<126 560 9

633 837

<87 53 245

  • Note that site T48 is the same location as site T05, and site T85 is the same location as site T06.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 47 of 54 Annual Radiological Environmental Operating Report Page 16 of 16 Monitoring Results Tables Table 24: Supplemental Broad Leaf Vegetation - Gamma Analysis: Gamma Isotopic Units: pCi/kg (wet)

Location Collection Date Sample Type Be-7 K-40 Cs-137 Ra-226 REQUIRED LLD 80 T43 (Indicator) 01/07/2020 Corn

<68 3130

<8

<14 T44 (Indicator) 02/11/2020 Corn

<55 2230

<7

<14 T45 (Indicator) 04/08/2020 Green String Beans

<136 2348

<18

<337

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 48 of 54 Annual Radiological Environmental Operating Report Page 1 of 3 Interlaboratory Comparison Program Results 1.0 Summary The Interlaboratory Comparison Program consists of participating in the DOE Mixed Analyte Performance Evaluation Program (MAPEP).

This program provides similar testing (matrices, nuclides, and levels) as the former EPA Interlaboratory Comparison Program and is referred to as the Mixed Analyte Performance Evaluation Program (MAPEP).

The samples are analyzed using the methods applicable to the REMP (gamma spectroscopy, Gross Beta, and Tritium for water).

From the MAPEP handbook:

Acceptance criteria were developed from a review of precision and accuracy data compiled by other performance evaluation programs (PEPs), the analytical methods literature, from several MAPEP pilot studies, and from what is considered reasonable, acceptable, and achievable for routine analyses among the more experienced laboratories.

The State laboratory participated in MAPEP 42 and 43. These satisfied the requirement of Control 5.3 of the ODCM for the Interlaboratory Comparison Program.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 49 of 54 Annual Radiological Environmental Operating Report Page 2 of 3 Interlaboratory Comparison Program Results Table 25: DOEs Mixed Analyte Performance Evaluation Program (MAPEP) 42 RESULTS Evaluation: A = Acceptable, W = Acceptable with Warning, N = Not Acceptable, NR = Not Reported A false positive test with an A designation flag identifies the result as less than the detectable activity, since MAPEP does not report zero values. Sensitivity Evaluation has no acceptance range but an identified value at low activity.

Program status Radionuclide Result Ref.

Value Flag (Evaluation)

Acceptance Range Matrix: RdF Air Filter Bq/filter Required MN54 0.001 A

False Positive Test Required CO57 1.523 1.50 A

1.05-1.95 Required CO60 1.270 1.23 A

0.86-1.60 ZN65 1.380 1.18 A

0.83-1.53 Required CS134 0.585 0.600 A

0.420-0.780 Required CS137 0.766 0.735 A

0.515-0.956 Matrix: GrF Air Filter Bq/filter Required Gross Beta 2.13 2.00 A

1.00-3.00 Required Gross Alpha 1.71 1.24 A

0.37-2.11 Matrix: MaS Soil Bq/kg Required K40 652.00 625 A

438-813 MN54 980.20 945 A

662-1229 CO57 994.20 1071 A

750-1392 CO60 0.87 A

False Positive Test ZN65 804.80 751 A

526-976 CS134 1166.54 1114 A

780-1448 Required CS137 1054.0 1020 A

714-1326 Matrix: MaW Water Bq/L Required H3 211.43 196 A

137-255 MN54 19.95 19.6 A

13.7-25.5 CO57 19.08 19.7 A

13.8-25.6 Required CO60 10.45 10.6 A

7.4-13.8 ZN65 22.120 22.2 A

15.5-28.9 Required CS134 17.547 18.5 A

13.0-24.1 Required CS137 11.68 11.3 A

7.9-14.7 SR90

-0.028 A

False Positive Test Matrix: RdV Vegetation, Bq/sample MN54 4.867 4.58 A

3.21-5.95 CO57

-0.011 A

False Positive Test Required CO60 2.733 2.79 A

1.95-3.63 ZN65 3.983 3.79 A

2.65-4.93 CS134 3.664 3.82 A

2.67-4.97 Required CS137 2.867 2.77 A

1.94-3.60

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 50 of 54 Annual Radiological Environmental Operating Report Page 3 of 3 Interlaboratory Comparison Program Results Table 26: DOEs Mixed Analyte Performance Evaluation Program (MAPEP) 43 RESULTS Evaluation: A = Acceptable, W = Acceptable with Warning, N = Not Acceptable, NR = Not Reported A false positive test with an A designation flag identifies the result as less than the detectable activity, since MAPEP does not report zero values. Sensitivity Evaluation has no acceptance range but an identified value at low activity.

Program status Radionuclide Result Ref.

Value Flag (Evaluation)

Acceptance Range Matrix: RdF Air Filter Bq/filter Required MN54 1.433 1.40 A

0.98 - 1.82 Required CO57 0.005 A

False Positive Test Required CO60 1.632 1.73 A

1.21 - 2.25 ZN65 2.117 2.00 A

1.40 - 2.60 Required CS134 1.561 1.83 A

1.28 - 2.38 Required CS137 0.944 0.996 A

0.697 - 1.295 Matrix: GrF Air Filter Bq/filter Required Gross Beta 1.022 0.915 A

0.458 - 1.373 Required Gross Alpha 0.549 0.528 A

0.158 - 0.898 Matrix: MaS Soil Bq/kg Required K40 573.94 622 A

435 - 809 MN54 579.44 610 A

427 - 793 CO57 936.42 1100 A

770 - 1430 CO60 925.00 1000 A

700 - 1300 ZN65 448.06 470 A

329 - 611 CS134 682.26 710 A

497 - 923 Required CS137 0.80 A

False Positive Test Matrix: MaW Water Bq/L Required H3 381.57 360 A

252 - 468 MN54 0.010 A

False Positive Test CO57

-0.015 A

False Positive Test Required CO60 11.612 12.2 A

8.5 - 15.9 ZN65 17.212 16.9 A

11.8 - 22.0 Required CS134 13.549 15.2 A

10.6 - 19.8 Required CS137 14.268 14.3 A

10.0 - 18.6 SR90 11.468 11.6 A

8.1 - 15.1 Matrix: RdV Vegetation, Bq/sample:

MN54 6.261 5.84 A

4.09 - 7.59 CO57 7.992 6.67 A

4.67 - 8.67 Required CO60 4.425 4.13 A

2.89 - 5.37 ZN65 7.075 6.38 A

4.47 - 8.29 CS134 4.911 4.94 A

3.46 - 6.42 Required CS137 0.028 A

False Positive Test

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 51 of 54 Annual Radiological Environmental Operating Report Page 1 of 4 Industry Initiative Ground Water Protection Program 2020 1.0 Description of Program Turkey Point Nuclear maintains a sampling and analysis program to meet procedural requirements.

The procedures that govern the performance are EV-AA-100-1001, Fleet Ground Water Protection Program Implementing Guideline and 0-ADM-654, Ground Water Protection Program.

The sampling frequency is quarterly; more often if conditions warrant.

Sample assay is performed by a private contractor GEL lab.

2.0 Discussion The Turkey Point Nuclear site is surrounded on three sides by the closed cooling canal system.

This canal system, in addition to being the source of tertiary cooling, is the body of water receiving permitted liquid radiological waste the canal system tritium level averages was 9317 pCi/L in 2020 with a max concentration of 27,529 pCi/L. This supports the expectation to see tritium in subsurface water collected either on-site or off-site close to the (within the Owner Controlled Area) cooling canal system. Twenty-eight (28) wells were involved in the 2020 monitoring program; some locations have multiple (two or three) depths.

Samples are analyzed for Tritium & Gamma emitters. As conditions warrant, analysis included Fe-55, Ni-63, Sr-89/90 and alpha (all were < LLD).

3.0 Results The tritium results for the groundwater wells were from <MDA to 9380 pCi/L. All results were less than the limits of the Offsite Dose Calculation Manual, Table 5.1-2, Reporting Levels for Radioactivity Concentrations in Environmental Samples. Storm drain outfalls occasionally are below the tidal mark of the canal and will have ingress of canal water into the storm drain. The higher levels of tritium in the storm drain section are due to the canal water ingress into the storm drain.

Tabular results follow:

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 52 of 54 Annual Radiological Environmental Operating Report Monitoring Results Tables Table 27: Ground Water - Tritium Page 2 of 4 Analysis: Tritium Units: pCi/L Location First Quarter 2020 H-3 Second Quarter 2020 H-3 Third Quarter 2020 H-3 Fourth Quarter 2020 H-3 REQUIRED LLD 3,000 3,000 3,000 3,000 PTPED-1 237 270 101 101 CD-1 327 399 50 50 P-94-2 577 529 P-94-4 554 395 529 529 STP-1 52 84 PTN-MW-1s 4

244 PTN-MW-1i 232 197 PTN-MW-1d 1670 1410 PTN-MW-2s 143 25 PTN-MW-3s 37 66 PTN-MW-4s 80 88 45 45 PTN-MW-4i

-95 35 1610

-17 PTN-MW-4d

-6 1

45 6

PTN-MW-5s 209 951 951 PTN-MW-5i 208 334 136 89 PTN-MW-5d 1810 1590 1500 1500 PTN-MW-6s

-83

-90 PTN-MW-6i PTN-MW-6d 1180 1340 PTN-MW-7s 563 613 564 434 PTN-MW-7i 528 762 35.2

-57 PTN-MW-7d 27 125 151 120 PTN-MW-8s 4200 1760 2100 1300 PTN-MW-9s 633 1760 2100 843 PTN-MW-10s

-2

-43 PTN-MW-10i 643 923 PTN-MW-10d 16 44 PTN-MW-11s 58 106 94 94 PTN-MW-12s 726 470 582 582 NE StrmDrain 534 8240 612 1630 SE StrmDrain 9380 113 dry 5050 W StrmDrain 346 343 1570 4970 CRF StrmDrain dry dry dry dry

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 53 of 54 Annual Radiological Environmental Operating Report Page 3 of 4 Industry Initiative Ground Water Protection Program 2020 D. List of wells and their locations Well Name Location PTN-MW-1s PTN-MW-1i PTN-MW-1d Northeast of Switch Yard, South of entrance road to Fossil Plant PTN-MW-2s South Switch Yard by parking lot PTN-MW-3s Northeast of new Issues Warehouse PTN-MW-4s PTN-MW-4i PTN-MW-4d SW corner of parking lot South of Training Bldg.

PTN-MW-5s PTN-MW-5i PTN-MW-5d SW of CRF, by canal PTN-MW-6s PTN-MW-6d NE of site in the berm for fossil oil tanks PTN-MW-7s PTN-MW-7i PTN-MW-7d NE of RCA, by Neutralization Tank PTN-MW-8s Near U3 RWST PTN-MW-9s Near U4 RWST PTN-MW-10s PTN-MW-10i PTN-MW-10d SE of Radwaste Bldg. by S/G Bldg.

PTN-MW-11s South of truck entrance to Rad Waste Bldg.

PTN-MW-12s West of Condenser Polisher road STP-1 West of Maintenance Bldg. on corner or road into parking lot P-94-4 East of Dressout Building, under delay fence P-94-2 By Neutralization Basin, East of the RCA CD-1 By Neutralization Basin, East of the RCA PTPED-1 By Neutralization Basin, East of the RCA Note: s, i and d refer to well depth: shallow - 20 ft., intermediate - 40 ft. and deep - 60 ft Maps depicting the well locations follow.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 54 of 54 Annual Radiological Environmental Operating Report Page 4 of 4 Industry Initiative Ground Water Protection Program 2020 Figure 5: Onsite Tritium Monitoring Wells