L-2021-099, 2020 Annual Radiological Environmental Operating Report

From kanterella
(Redirected from L-2021-099)
Jump to navigation Jump to search
2020 Annual Radiological Environmental Operating Report
ML21133A478
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 05/10/2021
From: Hess R
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2021-099
Download: ML21133A478 (55)


Text

May 10, 2021 L-2021-099 10 CFR 50.36b F=PL.

U. S. Nuclear Regulatory Commission Attn : Document Control Desk Washington, D.C. 20555-00001 Re: Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 2020 Annual Radiological Environmental Operating Report Enclosed is the 2020 Annual Radiological Environmental Operating Report for Turkey Point Units 3 and 4, as required by Technical Specification 6.9.1.3 .

Should there be any questions or comments regarding this information, please contact Mr. Robert J.

Hess, Licensing Manager, at (305) 246-4112 .

Licensing Manager Turkey Point Nuclear Plant SM Enclosure cc: Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, Turkey Point Plant Florida Power & Light Company 9760 S.W. 3441" Street Homestead , FL 33035

Page 1 of 54 Plant: Turkey Point Nuclear Units 3 & 4 YEAR: 2020 Docket NOS Number: 50-250, 50-251 Annual Radiological Environmental Operating Report

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 2 of 54 Annual Radiological Environmental Operating Report TABLE OF CONTENTS 1.1 EXECUTIVE

SUMMARY

.......................................................................................................... 5 1.2 Radiological Environmental Monitoring Program.................................................................. 5 1.3 Reporting Levels................................................................................................................ 6 1.4 Sample Deviations ............................................................................................................. 6 1.5 Program Modifications........................................................................................................ 6

2.1 INTRODUCTION

..................................................................................................................... 7 2.2 Radiological Environmental Monitoring Program.................................................................. 7 A. Purpose......................................................................................................................... 7 2.3 Pathways Monitored........................................................................................................... 8 2.4 Land Use Census .............................................................................................................. 8 3.0 RADIOLOGICAL ENVIRONMENTAL SAMPLING PROGRAM REQUIREMENTS...................... 9 4.1 INTERPRETATION AND TRENDS OF RESULTS .................................................................. 16 4.2 Air Particulate and Radioiodine Sample Results ................................................................ 16 4.3 Thermoluminescent Dosimetry (TLD) Sample Results....................................................... 17 4.4 Waterborne Sample Results ............................................................................................. 17 4.4.1 Surf ace Water Results.................................................................................................17 4.4.2 Sediment Sample Results ............................................................................................18 4.5 Ingestion Sample Results ................................................................................................. 18 4.5.1 Crustacea and Fish Sample Results ...............................................................................18 4.5.2 Broad Leaf Vegetation Sample Results ...........................................................................18 4.6 Land Use Census Results ................................................................................................ 18 4.7 Interlaboratory Comparison Results .................................................................................. 26 5.0 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

......................... 26

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 3 of 54 Annual Radiological Environmental Operating Report ATTACHMENTS - Sample Deviations..................................................................................................... 30 - Monitoring Results Tables.......................................................................................... 31 - Interlaboratory Comparison Program Results.............................................................. 48 1.0 Summary................................................................................................................................... 48 - Industry Initiative Ground Water Protection Program, 2020.......................................... 51 1.0 Description of Program............................................................................................................... 51 2.0 Discussion................................................................................................................................. 51 3.0 Results ............................................................................................................................... 51 TABLES Table 1: Exposure Pathway - Airborne ..................................................................................... 9 Table 2: Exposure Pathway - Direct Radiation ........................................................................ 10 Table 3: Exposure Pathway - Waterborne .............................................................................. 12 Table 4: Exposure Pathway - Ingestion .................................................................................. 13 Table 5: Land Use Census - 2020 Nearest Residence, Garden and Milk Animal Within 5 Miles........................................................................................................................ 19 Table 6: Radiological Environmental Monitoring Program Summary ........................................ 27 Table 7: Sample Deviations Table.......................................................................................... 30 Table 8: Air Particulate - Gross Beta ...................................................................................... 32 Table 9: Air Particulate Composite - Gamma .......................................................................... 33 Table 10: Air Cartridges - Iodine-131 ..................................................................................... 34 Table 11: Direct Radiation - Indicators ................................................................................... 35 Table 12: Direct Radiation- Controls ...................................................................................... 35 Table 13: Surface Water - Tritium and Gamma ....................................................................... 36 Table 14: Shoreline Sediment - Gamma ................................................................................. 37 Table 15: Crustacea - Gamma................................................................................................ 38 Table 16: Fish - Gamma......................................................................................................... 39 Table 17: Broad Leaf Vegetation - Gamma............................................................................. 40

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 4 of 54 Annual Radiological Environmental Operating Report TABLES (CONT'D)

Table 18: Supplemental Direct Radiation - Indicators .............................................................. 41 Table 19: Supplemental Air Particulate - Gross Beta............................................................... 42 Table 20: Supplemental Air Particulate Composite - Gamma................................................... 43 Table 21: Supplemental Air Cartridges - Iodine-131 ................................................................ 44 Table 22: Supplemental Surface Water - Tritium and Gamma ................................................. 45 Table 23: Supplemental Shoreline Sediment - Gamma ........................................................... 46 Table 24: Supplemental Broad Leaf Vegetation - Gamma ....................................................... 47 Table 25: DOE's Mixed Analyte Performance Evaluation Program (MAPEP) 42 results ................................................................................................................................... 49 Table 26: DOE's Mixed Analyte Performance Evaluation Program (MAPEP) 43 results ................................................................................................................................... 50 Table 27: Ground Water - Tritium ........................................................................................... 52 FIGURES Figure 1: Sample Collection Sites - Near Station .................................................................... 14 Figure 2: Sample Collection Sites - Distant from Station ......................................................... 15 Figure 3: Turkey Point 2020 REMP Gross Beta in Air pCi/m3 .................................................. 16 Figure 4: 2020 PTN Direct Exposure TLDs: Quarterly Collection ............................................. 17

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 5 of 54 Annual Radiological Environmental Operating Report 1.1 EXECUTIVE

SUMMARY

1.2 Radiological Environmental Monitoring Program The data obtained through the Turkey Point Radiological Environmental Monitoring Program (REMP) verifies that the levels of radiation and concentrations of radioactive materials in environmental samples are not increasing. These measurements verify that the dose or dose commitment to members of the public, due to operation of Turkey Point Units 3 & 4, during the surveillance year, is well within the limits established by 10 CFR 50, Appendix I. The sampling period was from January 1, 2020 to December 31, 2020. Additionally, supplemental samples collected by the State of Florida, DOH, do not indicate adverse trends in the radiological environment.

All required lower limit of detection (LLD) capabilities were achieved in all sample analyses during 2020, as required by the Turkey Point Units 3 & 4 Technical Specifications. No measurable levels of radiation above baseline levels attributable to Turkey Point Nuclear operation were detected in the vicinity of PTN. The 2020 Radiological Environmental Monitoring Program thus substantiated the adequacy of source control and effluent monitoring at Turkey Point Nuclear with no observed impact of plant operations on the environment.

Turkey Point Nuclear established the REMP prior to the stations becoming operational to provide data on background radiation and radioactivity normally present in the area. PTN has continued to monitor the environment by sampling air, water, sediment, crustacea, fish and broadleaf vegetation, as well as measuring direct radiation. PTN also samples milk if milk-producing animals used for human consumption are present within five miles (8 km) of the plant.

The REMP includes sampling indicator and control locations within an approximate 20-mile radius of the plant. The REMP utilizes indicator locations near the site to show any increases or buildup of radioactivity that might occur due to station operation and control locations farther away from the site to indicate the presence of only naturally occurring radioactivity. PTN personnel compare indicator results with control results to assess any impact PTN operation might have had on the surrounding environment.

In 2020, environmental samples were collected for radiological analysis. The results of indicator locations were compared with control locations. It was concluded that no significant relationship exists between PTN operation and effect on the area around the plant. The review of 2020 data showed radioactivity levels in the environment were undetectable in many locations and near background levels in significant pathways.

Radiological environmental monitoring for the Turkey Point Plant is conducted by the State of Florida, Department of Health (DOH). Samples are collected and analyzed by DOH personnel. Samples are analyzed at the DOH Environmental Radiation Control Laboratory in Orlando, Florida. The 2020 Radiological Surveillance Quarterly Report data is provided by the State of Florida Bureau of Radiation Control and is presented in Attachment 2.

The State of Florida is not involved in the (Industry Initiative) ground water monitoring program.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 6 of 54 Annual Radiological Environmental Operating Report 1.3 Reporting Levels No samples equaled or exceeded reporting levels.

1.4 Sample Deviations During 2020, environmental sampling was performed for seven media types addressed in the ODCM and for direct radiation. A total of 801 samples of the 802 scheduled were obtained. Of the scheduled samples, 99.9 percent were collected and analyzed in accordance with the requirements specified in the ODCM.

Attachment 1 contains the listing of sample deviations and actions taken.

1.5 Program Modifications

  • There were no program modifications during the reporting period.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 7 of 54 Annual Radiological Environmental Operating Report

2.1 INTRODUCTION

This report is submitted pursuant to Specification 6.9 of Turkey Point Units 3 & 4 Technical Specifications. The Annual Radiological Environmental Operating Report provides information, summaries and analytical results pertaining to the Radiological Environmental Monitoring Program for the calendar year indicated. This report covers surveillance activities described in the Offsite Dose Calculation Manual (ODCM) meeting the requirements of Unit 3 and Unit 4 Technical Specifications.

2.2 Radiological Environmental Monitoring Program The Radiological Environmental Monitoring Program for the Turkey Point Plant is conducted pursuant to Control 5.1 of Turkey Point Unit 3 & 4 ODCM.

A. Purpose The purpose of the Radiological Environmental Monitoring Program is to provide representative measurements of radiation and of radioactive materials in those exposure pathways and for those radionuclides which lead to the highest potential radiation exposures of members of the public resulting from station operation.

The Radiological Environmental Monitoring Program also supplements the radiological effluent monitoring program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and the modeling of the environmental exposure pathways.

Sample Locations, Types and Frequencies:

  • Direct radiation gamma exposure rate is monitored continuously at 23 locations by thermoluminescent dosimeters (TLDs). TLDs are collected and analyzed quarterly.
  • Airborne radioiodine and particulate samplers are operated continuously at six locations. Samples are collected and analyzed weekly. Analyses include Iodine-131, gross beta, and gamma isotopic measurements.
  • Surface water samples are collected from three locations. Samples are collected and analyzed monthly. Analyses include gamma isotopic and tritium measurements.
  • Shoreline sediment samples are collected from three locations coinciding with the locations for surface water samples. Samples are collected and analyzed semi-annually. Sediment samples are analyzed by gamma isotopic measurements.
  • Fish and invertebrate samples are collected from two locations coinciding with two of the locations for surface water samples. Samples are collected and analyzed semi-annually. Fish and invertebrate samples are analyzed by gamma isotopic measurements.
  • Broad leaf vegetation samples are collected from three locations. Samples are collected and analyzed monthly. Broad leaf vegetation samples are analyzed by gamma isotopic measurements.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 8 of 54 Annual Radiological Environmental Operating Report Table 1 through 4 provides specific information pertaining to sample locations, types, and frequencies.

Note: Ground Water Protection, NEI Initiative: The program and results are described in Attachment 4.

2.3 Pathways Monitored The airborne, direct radiation, waterborne and ingestion pathways are monitored as required by Control 5.1 of Turkey Point Unit 3 & 4 ODCM. A description of the REMP utilized to monitor the exposure pathways is described in the attached Tables and Figures.

Section 4.0 of this report provides a discussion of 2020 sampling results with Section 5.0 providing a summary of results for the monitored exposure pathways.

2.4 Land Use Census PTN conducts a land use census annually, as required by Turkey Point Units 3 & 4 ODCM. The purpose of this census is to identify changes in uses of land within five miles of PTN that would require modifications to the REMP and the Offsite Dose Calculation Manual (ODCM). Section 4.5 on the report contains a narrative on the results of the 2020 land use census.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 9 of 54 Annual Radiological Environmental Operating Report 3.0 RADIOLOGICAL ENVIRONMENTAL SAMPLING PROGRAM REQUIREMENTS Table 1: Exposure Pathway - Airborne Sample Point Description Sampling and Collection Requirement Type and Frequency of Analyses Distance and Direction Frequency RADIOIODINE AND PARTICULATES

  • T-51 (2 mi. NNW) - Entrance Area to Biscayne National Park.

5 sample indicator locations and 1 sample control location.

  • T-57 (4 mi. NW) - Siren Pole 27, intersection of SW 112th Ave and SW 304th St.
  • T-58 (1 mi. NW) - Turkey Point
  • Radioiodine Canisters - I-131 analysis weekly.

Entrance Road. Continuous sampler operation with sample collection weekly or

  • Air Particulate - Gross beta radioactivity analysis
  • T-72 (<1 mi. WSW) - Just more frequently if required by following filter change.

before entrance to Land dust loading.

Utilizations access gate.

  • Air Particulate - Gamma Isotopic analysis quarterly.
  • T-41 (1.6 mi. WNW) - Palm Dr.

West of FPL Satellite School near the site boundary.

  • T-64* (22 mi. NNE) - Natoma Substation, 2475 SW 16 Ct.
  • Denotes Control sample

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 10 of 54 Annual Radiological Environmental Operating Report Table 2: Exposure Pathway - Direct Radiation Sample Point Description Distance Sampling and Requirement Type and Frequency of Analyses and Direction Collection Frequency TLDS

  • N-2 (2 mi N) - Convoy Point 22 indicator sample locations and 1 control
  • N-7 (7.1 mi N) - Black Point Marina Quarterly
  • mR exposure quarterly.

sample location. parking lot on siren pole

  • N-10 (10.6 mi N) - Old Cutler Rd across from Perdue Med. Ctr. On siren pole.
  • NNW-2 (2.2 mi NNW) - East End of N. Canal Dr. on siren pole E. of 117th Ave.
  • NNW-10 (9.2 mi NNW) - Bailes Rd.

E. of US 1 on siren pole.

  • NW-1 (1.4 mi NW) - Turkey Point Entrance Rd.
  • NW-5 (3.9 mi NW) - Intersection of Mowry Dr. and 117th Ave. on siren pole.
  • NW-10 (10 mi NW) - On Newtown Rd. N. of Coconut Palm Drive on siren pole.
  • W-5 (5.3 mi W) - Palm Drive 0.3 mi west of Tallahassee Rd.
  • WNW-10 (9.8 mi WNW) - NW 2nd Ave. S. of Campbell Dr. at Hmstd.

Middle School on siren pole.

  • W-1 (0.7 mi W) - On site north side of Discharge Canal.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 11 of 54 Annual Radiological Environmental Operating Report Table 2: Exposure Pathway - Direct Radiation Sample Point Description Distance Sampling and Requirement Type and Frequency of Analyses and Direction Collection Frequency TLDS (Contd)

  • W-9 (8.6 mi W) - Card Sound Rd. 0.6 mi SSE of US 1 on siren pole.

22 indicator sample locations and 1 control Quarterly

  • mR exposure quarterly.

sample location.

  • WSW-8 (7.8 mi WSW) - Card Sound Rd. 3.4 mi. SSE of US 1 on siren Pole.
  • SW-1 (1 mi SW) - On site near land utilization offices.
  • SSE-1 (1 mi SSE) - On-site South-East side of cooling canals at Turtle Point.
  • SW-8 (8 mi SW) - Card Sound Rd. 5 mi. SSE of US 1 at entrance to Navy facility.
  • SSW-5 (5 mi SSW) - On site, southwest corner of cooling canals.
  • SSW-10 (10 mi SSW) - At Card Sound Bridge on siren pole.
  • S-5 (5 mi S) - On site, south east end of cooling canals.
  • S-10 (10 mi S) - Card Sound Road at Steamboat Creek.
  • SSE-10 (9 mi SSE) - Ocean Reef.
  • NNE-22* (22.6 mi NNE) - Natoma Substation.
  • WNW2 (1.6 mi WNW) - Palm Dr.

West of FPL Satellite School, near Site Boundary.

  • Denotes Control sample

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 12 of 54 Annual Radiological Environmental Operating Report Table 3: Exposure Pathway - Waterborne Sample Point Description Distance Sampling and Requirement Type and Frequency of Analyses and Direction Collection Frequency

  • T-42 (<1 mi. ENE) - Biscayne Bay at Turkey Point.

SURFACE WATER Grab samples Monthly

  • Gamma isotopic analysis and tritium analysis
  • T-81 (6 mi. S) - Card Sound, near monthly.

2 indicator sample locations and 1 control Mouth of Old Discharge Canal.

sample location.

  • T-67* (13-18 mi. N, NNE) - Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park SEDIMENT FROM SHORELINE
  • T-42 (<1 mi ENE) - Biscayne Bay at Turkey Point.

2 indicator sample locations and 1 control Semi-annually

  • Gamma isotopic analysis semi-annually.

sample location. Locations coincide with the

  • T-81 (6 mi. S) - Card Sound, near surface water sample locations. Mouth of Old Discharge Canal.
  • T-67* (13-18 mi. N, NNE) - Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park
  • Denotes Control sample

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 13 of 54 Annual Radiological Environmental Operating Report Table 4: Exposure Pathway - Ingestion Sample Point Description Distance Sampling and Collection Requirement Type and Frequency of Analyses and Direction Frequency CRUSTACEA AND FISH

  • T-81 (6 mi. S) - Card Sound, near Mouth of Old Discharge Canal.
  • 1 indicator sample location and 1 control Semi-annually Gamma isotopic analysis semi-annually.

sample location.

  • T-67* (13-18 mi. N, NNE) - Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park BROADLEAF VEGATATION
  • T-40 (3 mi W) - South of Palm Dr. on S.W. 117th Street Extension.
  • 2 indicator sample locations and 1 control Monthly Gamma isotopic analysis monthly.

sample location.

  • T-41 (2 mi WNW) - Palm Dr. West of FPL Satellite School near the site boundary.
  • T-67* (13-18 mi. N, NNE) - Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park
  • Denotes Control sample

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 14 of 54 Annual Radiological Environmental Operating Report Figure 1: Sample Collection Sites - Near Station

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 15 of 54 Annual Radiological Environmental Operating Report Figure 2: Sample Collection Sites - Distant from Station

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 16 of 54 Annual Radiological Environmental Operating Report 4.1 INTERPRETATION AND TRENDS OF RESULTS 4.2 Air Particulate and Radioiodine Sample Results In 2020 there were no samples above the LLD for I-131. Indicator gross beta air particulate results for 2020 were comparable to results obtained from 2017-2019 of the operational REMP. Results are reported in picocuries per cubic meter (pCi/m3).

Monitoring Period Result 2017 - 2019 (Minimum Value) 0.002 2020 Average Value 0.012 2017 - 2019 (Maximum Value) 0.032 Gross beta activity is attributed to naturally occurring radionuclides. Table 6, which include gross beta concentrations and provide a comparison of the indicator and control means and ranges emphasizes the consistent trends seen in this pathway to support the presence of naturally occurring activity. Figure 3 is a comparison of the weekly Gross Beta results for 2020.Therefore, it can be concluded that the airborne pathway continues to be unaffected by Turkey Point Nuclear operations.

Figure 3: Turkey Point 2020 REMP Gross Beta in Air, pCi/m3 0.08 0.07 0.06 0.05 0.04 Conc . pCi/m3 0.03 0.02 0.01 0.00 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 week of year Minimum Average Maximum

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 17 of 54 Annual Radiological Environmental Operating Report 4.3 Thermoluminescent Dosimetry (TLD) Sample Results Turkey Point Nuclear reports relies on comparison of the indicator locations to the control as a measure of plant impact. Turkey Point Nuclears comparison of the indicator to the control, as seen in Table 6, identified no noticeable trend that would indicate that the ambient radiation levels are being affected by plant operations. In addition, the quarterly indicator averages shown in the TLD radiation dose comparison graph below shows the 2020 indicator results are comparable to control location results. Overall, Turkey Point Nuclear concluded that the ambient radiation levels are not being affected by plant operations.

4.4 Waterborne Sample Results Analytical results for 2020 surface water samples were similar to those reported in previous years. Gamma radionuclides and tritium analytical results for 2020 waterborne samples were below the ODCM-required LLD similar to those reported in previous years. These results are further explained below.

4.4.1 Surface Water Results Samples were collected from two indicator and one control location and analyzed for gamma radionuclides and tritium. Tritium was detected in 2 out of 24 indicator location samples with an average concentration of 93 pCi/L which is consistent with results seen in previous operational years. There were no plant related gamma radionuclides detected in any of the control or indicator location samples. Therefore, the operation of Turkey Point Nuclear had no definable impact on this waterborne pathway during 2020.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 18 of 54 Annual Radiological Environmental Operating Report 4.4.2 Shoreline Sediment Sample Results Sediment samples were collected from two indicators and one control location in 2020 and analyzed for gamma radionuclides. Plant related gamma radionuclides were below the LLD limits at both indicator and control locations. Turkey Point Nuclear operations had no significant impact on the environment or public by this waterborne pathway.

4.5 Ingestion Sample Results 4.5.1 Crustacea and Fish Sample Results Crustacea and Fish samples were collected from one indicator and one control location and analyzed for gamma radionuclides. In 2020, gamma radionuclides were below detectable limits which are consistent with the results seen in previously operational years. Therefore, based on these measurements, Turkey Point Nuclear operations had no significant radiological impact upon the environment or public by this ingestion pathway.

4.5.2 Broad Leaf Vegetation Sample Results The REMP has detected radionuclides prior to 1990 that are attributable to other sources. These include the radioactive plume release due to reactor core degradation at Chernobyl Nuclear Power Plant in 1986 and atmospheric weapons testing.

In 2020, Broad Leaf Vegetation samples were collected from two indicator and one control locations and analyzed for gamma radionuclides. The 2020 Cs-137 was detected in samples collected from the indicator and control locations. This activity identified could be from weapons fallout testing 30-40 years ago and reactor accidents at Chernobyl and are contributors. Therefore, based on these measurements, Turkey Point Nuclear operations had no significant radiological impact upon the environment or public by this ingestion pathway.

4.6 Land Use Census Results The latest land use census (performed in 2020) did not identify any new locations that yielded a calculated dose or dose commitment greater than those currently calculated (see Table 5).

The land use census identified no changes in the new resident census.

There were no changes in the milk cows/goats or garden census in 2020.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 19 of 54 Annual Radiological Environmental Operating Report Table 5: Land Use Census -2020 Nearest Residence, Garden, and Milk Animal Within Five Miles SECTOR NEAREST NEAREST NEAREST RESIDENCE/BUSINESS GARDEN (A) MILK ANIMAL N 1.9 mi @ 349° *

  • 1.98 mi @ 349° 2.0 mi @ 354° NNE * *
  • NE * *
  • ENE * *
  • E * *
  • ESE * *
  • S * *
  • WSW * *
  • W * *
  • WNW 1.7 mi @ 302° 4.5 mi @ 303°
  • 3.7 mi @ 302° 6.0 mi @ 295° NW 3.6 mi @ 304° *
  • 3.7 mi @ 311° 3.8 mi @ 316° 3.9 mi @ 314° NNW
  • 4.4 mi @ 333° 4.4 mi @ 332° 4.7 mi @ 328° 4.7 mi @ 328° (A) - Only gardens with an estimated total area of 500 square feet, or more, and producing green leafy vegetables are considered.
  • - No suitable sites were located within a five-mile range.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 20 of 54 Annual Radiological Environmental Operating Report TURKEY POINT RESIDENCE SURVEY RESULTS August 2020 Range Sector Bearing Nearest Residence/Business Location N (A) 1.9 miles This is the Homestead Bayfront Park complex. Contact is Jim 349° Wyath. Office hours are 8:30 to 4:30, 7 days a week. Some occasional overnight recreational occupancy (up to 4 nights) on boats at the marina. Approximately 25 workers, 7 days a week, hours and number of varies. Summer weekends can see 1000+

visitors. There is always someone here 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> with more workers in the summer than the rest of the year (February thru September have the highest peak of workers). LaPlaya restaurant is open at the park with 8 to 10 employees weekdays from 11am to 8:30pm. Weekends open till 10:00 and may have up to 12 employees. N25° 27.683 W80° 20.200.

N (B) 1.98 miles South Glade Outfitters. Located on opposite side of building from 349° office of Homestead Bayfront Park. Manager is Robert and have 2 employees. Hours are M - Th 7 am to 5 pm. Fri - Sun 7 am -

6 pm. Hours may vary depending on the weather.

N25° 27.767 W80° 20.206.

N (C) 2.0 miles Biscayne National Park at Convoy Point. No admin staff onsite 354° due to Covid-19. Calls have not been returned. Contact includes J. Ernest Jutte, Chief Administration, 305-242-7721 (office) 202-438-6636 (mobile) and Cindy Holl (administrator) 239-695-1114.

N25° 27.817 W80° 20.067.

NNE No residences were located within a five-mile range.

NE No residences were located within a five-mile range.

ENE No residences were located within a five-mile range.

E No residences were located within a five-mile range.

ESE No residences were located within a five-mile range.

SE No residences were located within a five-mile range.

SSE No residences were located within a five-mile range.

S No residences were located within a five-mile range.

SSW No residences were located within a five-mile range.

SW No residences were located within a five-mile range.

WSW No residences were located within a five-mile range.

W No residences were located within a five-mile range.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 21 of 54 Annual Radiological Environmental Operating Report TURKEY POINT RESIDENCE SURVEY RESULTS August 2020 (cont.)

Range Sector Bearing Nearest Residence/Business Location WNW (A) 1.7 miles FP&L daycare center and shooting range near the entrance to the 302° Turkey Point Plant. Contact is Yudisvel Judy Diaz, Director.

There are 11 employees with 60 children currently enrolled, ages 6 months to 5 yrs. Occasionally, they will have school aged children. The center is open from 6am to 6pm Monday thru Friday. The number of people and times at the shooting range varies. N25° 26.817 W80° 21.217.

WNW (B) 3.7 miles Two elderly people live at 11790 Canal Drive on the south side of 302° Canal Drive (SW 328th St) west of SW 117th Ave (no gardens).

Their son lives onsite on weekends, 2-3 nights/week. Residents plan on selling soon. Next door, to the east, is a makeshift produce stand which sells coconuts, limes, mandarin oranges, flowers, garlic, mangoes, papaya, avocado, honey, melons, sugar cane, ginger, plantains and pumpkins. Is not associated with the house next door. One employee may be working there during normal hours. N25° 27.767 W80° 22.867.

NW (A) 3.6 miles The Waste Management Homestead Landfill is located north of 304° Canal Drive (SW 328th St) and east of SW 117 th Ave. There are 9 full time employees onsite Monday thru Friday usually from 7 am to 3:30 pm. N25° 27.833 W80° 22.767.

NW (B) 3.7 miles 11000 SW 320th St. Per property records, this house is on land 311° zoned agriculture and the owners live in Texas. Unable to verify if anyone lives there because the gate is locked and the residence is too far from the road to see anything.

N25° 28.217 W80° 22.567.

NW (C) 3.8 miles High Hope Nursery at 11400 SW 316th St. Contact is George 316° Sprinkle, Owner and General Manager. This nursery has approximately 35 employees. Hours of operations are 7am to 5pm Monday thru Friday, with some work on Saturdays until noon. A couple lives here that also provide security.

N25° 28.441 W80° 22.430.

NW (D) 3.9 miles Snapper Creek Nursery at 11600 SW 316th Street. 14 workers 314° that work Monday thru Friday 7 am to 5 pm. Contact is Elmer.

Security is provided by another person who lives onsite.

N25° 28.444 W80° 22.560.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 22 of 54 Annual Radiological Environmental Operating Report TURKEY POINT RESIDENCE SURVEY RESULTS August 2020 (cont.)

Range Sector Bearing Nearest Residence/Business Location NNW (A) 4.4 miles 29800 SW 107th Ave. Per property records, this is a small one 333° bedroom residence on land zoned as mixed use agricultural.

Appears lived in, but gate locked and no people onsite.

N25° 29.450 W80° 21.817.

NNW (B) 4.7 miles SFM Tree Farm. Entrance at SW 107th Ave & SW 296th St. Four 328° people work on the property Mon-Fri 6:30-5:30. Contact is Mario.

Owner lives off property in Miami. N25° 29.564 W80° 22.264.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 23 of 54 Annual Radiological Environmental Operating Report TURKEY POINT GARDEN SURVEY RESULTS August 2020 Range Nearest Garden Location (with estimated total area of 500 Sector Bearing square feet, or more, and producing green leafy vegetables).

N No suitable gardens were located within a five-mile range.

NNE No suitable gardens were located within a five-mile range.

NE No suitable gardens were located within a five-mile range.

ENE No suitable gardens were located within a five-mile range.

E No suitable gardens were located within a five-mile range.

ESE No suitable gardens were located within a five-mile range.

SE No suitable gardens were located within a five-mile range.

SSE No suitable gardens were located within a five-mile range.

S No suitable gardens were located within a five-mile range.

SSW No suitable gardens were located within a five-mile range.

SW No suitable gardens were located within a five-mile range.

WSW No suitable gardens were located within a five-mile range.

W No suitable gardens were located within a five-mile range.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 24 of 54 Annual Radiological Environmental Operating Report TURKEY POINT GARDEN SURVEY RESULTS August 2020 (cont.)

Range Nearest Garden Location (with estimated total area of 500 Sector Bearing square feet, or more, and producing green leafy vegetables).

WNW (A) 4.5 miles Thai Farms. South of Mowry Drive (SW 320th St) and about 0.6 303° miles west of Allapattah Rd (SW 117th Ave). Growing guava dragon fruit, papaya, palm, bamboo, and more. No one present.

Phone number on farm sign reached the previous owner who sold 3 years ago and does not know how to contact new owners.

N25° 28.217 W80° 23.467.

WNW (B) 6.0 miles Farm Share, Inc at 14125 SW 320th St, where farmers donate 295° locally grown produce to be given to charitable organizations.

Produce donations usually start in November and run through April. About 20 workers present from 8 am to 4:30 pm Monday thru Friday. The produce donated is usually tomatoes, bananas, squash, green beans, okra, corn, potatoes, watermelon and zucchini. The contact is now Nick Sanchez.

N25° 28.255 W80° 25.111.

NW No suitable gardens were located within a five-mile range.

NNW (A) 4.4 miles Under the vine. 11100 SW 296th St. Entrance at SW 107th Ave &

332° SW 296th St just east of SFM Tree Farm. Growing only dragon fruit. Open Mon-Sat 8:00-5:00. 3 employees plus the owner work here. No onsite residents. N25° 29.464 W80° 21.828.

NNW (B) 4.7 miles SFM Tree Farm. Entrance at SW 107th Ave & SW 296th St.

328° Noticed bananas, dragon fruit, plantain tress, coconuts and mangoes growing in various areas on the farm. Owner lives off property in Miami. Gate locked, waited 15 minutes, and did not see an employee. N25° 29.564 W80° 22.264.

Note: At the time of our survey, many fields in the area surveyed were bare soil or cover crops. Other than the sites already described above, the only non-ornamental crops known to have been grown in the survey area were: bananas, beans, corn, guava, malanga, papaya, eggplant, sorghum, squash, sugar cane, tambis, okra and melon.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 25 of 54 Annual Radiological Environmental Operating Report TURKEY POINT MILK ANIMAL SURVEY RESULTS August 2020 Sector Nearest Milk Animals (cows or goats).

N No potential milk animals were located within five miles.

NNE No potential milk animals were located within five miles.

NE No potential milk animals were located within five miles.

ENE No potential milk animals were located within five miles.

E No potential milk animals were located within five miles.

ESE No potential milk animals were located within five miles.

SE No potential milk animals were located within five miles.

SSE No potential milk animals were located within five miles.

S No potential milk animals were located within five miles.

SSW No potential milk animals were located within five miles.

SW No potential milk animals were located within five miles.

WSW No potential milk animals were located within five miles.

W No potential milk animals were located within five miles.

WNW No potential milk animals were located within five miles.

NW No potential milk animals were located within five miles.

NNW No potential milk animals were located within five miles.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 26 of 54 Annual Radiological Environmental Operating Report 4.7 Interlaboratory Comparison Results Attachment 3 contains result summary for Interlaboratory Comparison program for the Department of Energy Mixed Analyte Performance Evaluation Program (MAPEP).

These satisfied the requirement of Control 5.3 of the ODCM for the Interlaboratory Comparison Program.

5.1 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

1. Table 6, Radiological Environmental Monitoring Program Summary, summarizes data for the 2020 REMP program.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 27 of 54 Annual Radiological Environmental Operating Report Table 6: Radiological Environmental Monitoring Program Summary Indicator Locations Indicator (4)

(3)

Control Number of Sample Type Type / Number (2) (3) Mean (F)

(1) LLD Mean (F) Location [Highest Locations Mean Non-Routine (Units) of Analyses [Range] (3) (5)

[Range] Annual Mean] (F) [Range] Results GB / 312 0.01 0.0123 (250 / 260) T58 0.0129 (49 / 52) 0.0120 (51 / 52) 0

[0.0040 - 0.0290] (1 mi. NW) [0.0060 - 0.0290] [0.0010 - 0.0230]

GS / 24 Be-7 -- 0.1242 (20 / 20) T72 0.1375 (4 / 4) 0.1242 (4 / 4) 0

[0.0738 - 0.1750] (<1 mi. WSW) [0.1190 - 0.1720] [0.0926 - 0.1670]

Air Particulate 3

(pCi/m ) K-40 -- < LLD N/A N/A < LLD 0 Cs-134 0.05 < LLD N/A N/A < LLD 0 Cs-137 0.06 < LLD N/A N/A < LLD 0 Pb-210 -- 0.0093 (8 / 20) T58 0.0105 (1 / 4) 0.0103 (2 / 4) 0

[0.0058 - 0.0133] (1.3 mi. NW) [<LLD - 0.0105] [ 0.0082 - 0.0123]

I-131 / 312 0.07 < LLD N/A N/A < LLD 0 Airborne Iodine 3

(pCi/m )

Gamma / 87 (6) 3.4 (87 / 87) NW-10 4.1 (4 / 4) N/A 0 Direct Radiation Indicator TLD [2.4 - 4.7] (10 mi. NW) [3.8 - 4.4]

(µR/hour)

(6)

Direct Radiation Gamma / 4 N/A N/A N/A 3.7 (4 / 4) 0 Control TLD [3.5 - 4.1]

(µR/hour)

LEGEND:

(1)

- GB = Gross beta; I-131 = Iodine-131; H-3 = Tritium; GS = Gamma scan.

(2)

- LLD = Required lower limit of detection based on Turkey Point ODCM.

(3)

- Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parenthesis (F).

(4)

- Locations are specified (1) by name and (2) direction relative to reactor site.

(5)

- Non-routine results are those which exceed ten times the control station value. If no control station value is available, the result is considered non-routine if it exceeds ten times the preoperational value for the location.

(6)

- LLD is not defined in Turkey Point ODCM.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 28 of 54 Annual Radiological Environmental Operating Report Table 6: Radiological Environmental Monitoring Program Summary Indicator Locations Indicator (4)

(3) Control Number of Sample Type Type / Number (3) Mean (F)

(1) LLD (2) Mean (F) Location [Highest Locations Mean Non-Routine (Units) of Analyses [Range] (3) (5)

[Range] Annual Mean] (F) [Range] Results H-3 / 36 3,000 93 (2 / 24) T42, T81 93 (1 / 12) <LLD 0

[<LLD - 93] (<1 mi. ENE) [93]

(6 mi. S)

Surface Water (pCi/L)

GS / 36 K-40 -- 315 (24 / 24) T81 335 (12 /12) 255 (12 / 12) 0

[146 - 475] (6 mi. S) [264 - 433] [161 - 334]

GS / 6 Be-7 -- < LLD N/A N/A < LLD 0 K-40 -- 182 (3 / 4) T67 465 (2 / 2) 465 (2 / 2) 0

[92 - 308] (13 - 18 mi. N, NNE) [104 - 826] [104 - 826]

Cs-137 180 < LLD N/A N/A < LLD 0 Pb-210 -- 430 (2 / 4) T67 939 (1 / 2) 939 (1 / 2) 0

[393 - 466] (13 - 18 mi. N, NNE) [939] [<LLD - 939]

Sediment Ra-226 -- 546 (4 / 4) T67 1370 (1 / 2) 1370 (1 / 2) 0 (pCi/kg dry) [466 - 681] (13 - 18 mi. N, NNE) [1370] [<LLD - 1370]

Th-232 -- <LLD T67 245 (1 / 2) 245 (1 / 2) 0 (13 - 18 mi. N, NNE) [245] [<LLD - 245]

U-235 -- 52 (4 / 4) T67 182 (1 / 2) 182 (1 / 2) 0

[29 - 74] (13 - 18 mi. N, NNE) [182] [<LLD - 182]

U-238 -- 319 (4 / 4) T67 820 (1 / 2) 820 (1 / 2) 0

[247 - 467] (13 - 18 mi. N, NNE) [820] [<LLD - 820]

LEGEND:

(1)

- GB = Gross beta; I-131 = Iodine-131; H-3 = Tritium; GS = Gamma scan.

(2)

- LLD = Required lower limit of detection based on Turkey Point ODCM.

(3)

- Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parenthesis (F).

(4)

- Locations are specified (1) by name and (2) direction relative to reactor site.

(5)

- Non-routine results are those which exceed ten times the control station value. If no control station value is available, the result is considered non-routine if it exceeds ten times the preoperational value for the location.

(6)

- LLD is not defined in Turkey Point ODCM.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 29 of 54 Annual Radiological Environmental Operating Report Table 6: Radiological Environmental Monitoring Program Summary Indicator Locations Indicator (4)

(3) Control Number of Sample Type Type / Number (3) Mean (F)

(1) LLD (2) Mean (F) Location [Highest Locations Mean Non-Routine (Units) of Analyses [Range] (3) (5)

[Range] Annual Mean] (F) [Range] Results GS / 4 K-40 1525 (2 / 2) T81 1525 (2 / 2) 1415 (2 / 2)

-- 0 Crustacea [1400 - 1650] (6 mi. S) [1400 - 1650] [1350 - 1480]

(pCi/kg wet) Ra-226 706 (1 / 2) T81 706 (1 / 2) 370 (1 / 2)

-- 0

[<LLD - 706] (6 mi. S) [<LLD - 706] [<LLD - 370]

Ra-228 -- <LLD N/A N/A <LLD 0 GS / 4 K-40 -- 3120 (2 / 2) T81 3120 (2 / 2) 2190 (2 / 2) 0 Fish

[2900 - 3340] (6 mi. S) [2900 - 3340] [2020 - 2360]

(pCi/kg wet) Ra-226 -- < LLD N/A N/A < LLD 0 Ra-228 -- < LLD N/A N/A < LLD 0 GS / 36 Be-7 -- 1890 (24 / 24) T40 2135 (12 / 12) 1514 (12 / 24) 0

[998 - 3650] (3 mi. W / WNW) [998 - 3650] [723 - 2290]

K-40 -- 4254 (24 / 24) T41 4358 (12 / 12) 4068 (12 / 12) 0

[2280 - 5530] (1.6 mi. WNW) [2890 - 5530] [1860 - 5720]

Broad Leaf Cs-137 80 125 (11 / 24) T41 289 (4 / 12) 16 (3 / 12) 0 (pCi/kg wet) [6 - 981] (1.6 mi. WNW) [6 - 981] [10 - 27]

Pb-210 -- 634 (6 / 24) T41 724 (2 / 12) 296 (5 / 12) 0

[209 - 1239] (1.6 mi. WNW) [209 - 1239] [182 - 370]

Pb-212 -- 16 (1 / 24) T67 23 (1 / 12) 23 (1 / 12) 0

[16] 13 - 18 mi. N, NNE) [<LLD - 23] [<LLD - 23]

Ra-226 -- 193 (2 / 24) T40 256 (1 / 12) 32 (1 / 12) 0

[129 - 256] (3 mi. W / WNW) [<LLD - 256] [<LLD - 32]

LEGEND:

(1)

- GB = Gross beta; I-131 = Iodine-131; H-3 = Tritium; GS = Gamma scan.

(2)

- LLD = Required lower limit of detection based on Turkey Point ODCM.

(3)

- Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parenthesis (F).

(4)

- Locations are specified (1) by name and (2) direction relative to reactor site.

(5)

- Non-routine results are those which exceed ten times the control station value. If no control station value is available, the result is considered non-routine if it exceeds ten times the preoperational value for the location.

(6)

- LLD is not defined in Turkey Point ODCM.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 30 of 54 Annual Radiological Environmental Operating Report Attachment 1 Page 1 of 1 Sample Deviations Table 7: Sample Deviations Table Sample Comment Sample Media Date Problem Evaluation / Actions No. Location Affected Low pump flow & unable to adjust flowrate. Unable to adjust flowrate due to valve Air 1 T-41 06/24/20 Faulty Equipment being at maximum stroke. Replaced pump and flow meter. Flow adjusted and Sample continuous sampling restored. Condition Report (AR) # 02389161 Air Found in-line flow meter obstructed. Identified and replaced the obstructed in-line 2 Sample T-41 07/07/20 Faulty Equipment flow meter. AR# 02389161 Air Collection time not recorded on 11/4/20. An estimated time based on reading of 3 T-56 11/04/20 Data record Error Sample 539,100 at 12:05 on 11/09/20 was recorded. AR# 02389161 Sample Goat milk sample was unavailable this year. The farm has not had any milking 4 Milk T-99 11/30/20 Unavailable goats. AR# 02389161 Direct 5 SSW-10 12/10/20 Sample Missing TLD & cricket cage missing. Replaced cage & deployed new TLD. AR# 02389161 Radiation Pump ran for 2 hrs. on 12/16/20, then removed to replace failed pump at T58.

Air 6 T-52 12/16/20 Pump Failure Pump replaced on 12/17/20 & time interval adjusted to include runtime from Sample 12/16/20. AR# 02389161 Air Pump failed, estimated run time 101 out of 165 hours0.00191 days <br />0.0458 hours <br />2.728175e-4 weeks <br />6.27825e-5 months <br />. T-58 pump failed and 7 T-58 12/16/20 Pump Failure Sample replaced with T-52 pump on 12/16/20. AR# 02389161 Air Pump failed, estimated run time 78 out of 187 hours0.00216 days <br />0.0519 hours <br />3.091931e-4 weeks <br />7.11535e-5 months <br />. Pump failed and replace 8 T-64 12/16/20 Pump Failure Sample with pump from T-56 on 12/16/20. AR# 02389161 T-56 had no vacuum pump for approximately one day. The pump was removed Air 9 Sample T-56 12/16/20 Power Outage from service to replace the failing pump at T-64. A new pump was installed at this location on 12/17/20. AR# 02389161

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 31 of 54 Annual Radiological Environmental Operating Report ATTACHMENT 2 Monitoring Results Tables RADIOLOGICAL SURVEILLANCE OF FLORIDA POWER AND LIGHT COMPANY'S TURKEY POINT SITE 2020 First Quarter, 2020 Second Quarter, 2020 Third Quarter, 2020 Fourth Quarter, 2020

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 32 of 54 Annual Radiological Environmental Operating Report Attachment 2 Page 1 of 16 Monitoring Results Tables Table 8: Air Particulate - Gross Beta 3

Analysis: Gross Beta Units: pCi/m T41 T51 T57 T58(1) T64 End Date T72 (Indicator)

(Indicator) (Indicator) (Indicator) (Indicator) (Control)

LLD 0.01 0.01 0.01 0.01 0.01 0.01 01/07/2020 0.014 0.015 0.017 0.021 0.022 0.017 01/15/2020 0.014 0.009 0.013 0.012 0.014 0.011 01/21/2020 0.013 0.013 0.014 0.013 0.014 0.016 01/28/2020 0.013 0.013 0.011 0.012 0.016 0.013 02/05/2020 0.010 0.011 0.017 0.016 0.013 0.017 02/12/2020 0.014 0.016 0.014 0.013 0.015 0.011 02/19/2020 0.007 0.009 0.009 0.012 0.010 0.009 02/25/2020 0.005 0.005 0.004 0.006 0.004 <0.009 03/03/2020 0.010 0.014 0.013 0.014 0.013 0.009 03/10/2020 0.009 0.009 0.009 0.010 0.008 0.012 03/18/2020 0.010 0.012 0.008 0.010 0.008 0.012 03/25/2020 0.009 0.012 0.008 0.017 0.012 0.008 04/01/2020 0.007 0.011 0.010 0.008 0.010 0.009 04/08/2020 0.022 0.019 0.024 0.029 0.023 0.019 04/13/2020 0.018 0.025 0.025 0.026 0.021 0.019 04/22/2020 0.014 0.015 0.019 0.016 0.017 0.015 04/29/2020 0.010 0.020 0.016 0.017 0.014 0.015 05/06/2020 0.018 0.018 0.018 0.016 0.018 0.017 05/13/2020 0.016 0.016 0.015 0.016 0.018 0.015 05/18/2020 0.012 0.011 0.009 0.012 0.012 0.008 05/27/2020 0.013 0.012 0.013 0.015 0.014 0.017 06/03/2020 0.008 0.009 0.011 0.008 0.007 0.012 06/10/2020 0.010 0.009 0.011 0.014 0.011 0.010 06/17/2020 0.013 0.012 0.008 0.007 0.009 0.009 06/24/2020 0.010 0.008 0.006 0.009 0.006 0.005 06/30/2020 0.009 0.012 0.011 0.011 0.012 0.012 07/07/2020 0.008 0.012 0.007 0.011 0.016 0.011 07/13/2020 0.020 0.024 0.017 0.020 0.018 0.020 07/21/2020 0.011 0.011 0.012 0.011 0.013 0.013 07/27/2020 0.005 0.010 0.007 0.006 0.005 0.008 08/04/2020 0.013 0.013 0.011 0.015 0.013 0.014 08/11/2020 0.009 0.010 0.012 0.010 0.006 0.010 08/17/2020 0.012 0.012 0.014 0.007 0.011 0.016 08/26/2020 0.014 0.010 0.013 0.012 0.012 0.011 09/01/2020 0.011 0.010 0.007 0.006 0.008 0.012 09/08/2020 0.018 0.022 0.018 0.017 0.016 0.015 09/14/2020 <0.009 0.006 <0.009 <0.009 0.008 0.004 09/22/2020 0.007 0.007 0.009 0.006 0.006 0.010 09/29/2020 0.006 0.007 0.006 0.008 0.007 0.009 10/06/2020 0.010 0.011 0.010 0.007 0.010 0.010 10/12/2020 0.013 0.008 0.009 0.010 0.007 0.012 10/19/2020 0.009 0.010 0.009 0.011 0.008 0.009 10/26/2020 0.008 0.005 0.008 0.007 0.001 0.005 11/04/2020 0.013 0.011 0.014 0.006 0.015 0.012 11/10/2020 0.007 0.005 <0.011 <0.009 0.004 0.004 11/19/2020 0.012 0.012 0.010 0.012 0.009 0.011 11/25/2020 0.004 <0.008 <0.008 <0.007 <0.008 <0.007 12/02/2020 0.010 0.013 0.012 0.016 0.013 0.010 12/09/2020 0.019 0.019 0.011 0.016 0.018 0.019 12/16/2020 0.014 0.019 0.016 0.024 0.022 0.017 12/23/2020 0.017 0.021 0.019 0.020 0.016 0.020 12/29/2020 0.015 0.014 0.013 0.013 0.010 0.013 (1)

Station with highest annual mean.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 33 of 54 Annual Radiological Environmental Operating Report Attachment 2 Page 2 of 16 Monitoring Results Tables Table 9: Air Particulate Composite - Gamma Analysis: Gamma Isotopic Units: pCi/m 3 Location Collection Date Be-7 K-40 Cs-134 Cs-137 Pb-210 REQUIRED LLD -- -- 0.05 0.06 --

T41 (Indicator) 03/25/2020 0.1260 <0.0129 <0.0012 <0.0008 <0.0141 T51 (Indicator) 03/25/2020 0.1280 <0.0201 <0.0011 <0.0009 <0.0282 T57 (Indicator) 03/25/2020 0.1180 <0.0134 <0.0012 <0.0009 <0.0147 T58 (Indicator) 03/25/2020 0.1050 <0.0209 <0.0011 <0.0009 <0.0344 T64 (Control) 03/25/2020 0.1060 <0.0156 <0.0010 <0.0010 <0.0148 T72 (Indicator) 03/25/2020 0.1190 <0.0157 <0.0011 <0.0009 <0.0253 T41 (Indicator) 06/30/2020 0.1300 <0.0189 <0.0009 <0.0008 0.0133 T51 (Indicator) 06/30/2020 0.1220 <0.0142 <0.0012 <0.0010 0.0107 T57 (Indicator) 06/30/2020 0.1370 <0.0128 <0.0012 <0.0011 <0.0154 T58 (Indicator) 06/30/2020 0.1240 <0.0183 <0.0011 <0.0012 <0.0303 T64 (Control) 06/30/2020 0.1310 <0.0196 <0.0009 <0.0006 0.0123 T72 (Indicator) 06/30/2020 0.1390 <0.0127 <0.0012 <0.0009 <0.0154 T41 (Indicator) 09/29/2020 0.0738 <0.0134 <0.0011 <0.0008 0.0058 T51 (Indicator) 09/29/2020 0.0939 <0.0218 <0.0008 <0.0007 0.0086 T57 (Indicator) 09/29/2020 0.0949 <0.0223 <0.0013 <0.0010 0.0058 T58 (Indicator) 09/29/2020 0.0845 <0.0131 <0.0014 <0.0011 <0.0155 T64 (Control) 09/29/2020 0.0926 <0.0197 <0.0010 <0.0006 0.0082 T72 (Indicator) 09/29/2020 0.1200 <0.0208 <0.0011 <0.0009 <0.0088 T41 (Indicator) 12/29/2020 0.1440 <0.0172 <0.0010 <0.0009 0.0079 T51 (Indicator) 12/29/2020 0.1750 <0.0134 <0.0016 <0.0012 <0.0155 T57 (Indicator) 12/29/2020 0.1440 <0.0179 <0.0008 <0.0008 0.0115 T58 (Indicator) 12/29/2020 0.1340 <0.0142 <0.0015 <0.0011 0.0105 T64 (Control) 12/29/2020 0.1670 <0.0211 <0.0010 <0.0009 <0.0105 T72 (Indicator) 12/29/2020 0.1720 <0.0158 <0.0013 <0.0010 <0.0155

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 34 of 54 Annual Radiological Environmental Operating Report Attachment 2 Page 3 of 16 Monitoring Results Tables Table 10: Air Cartridges - Iodine-131 3

Analysis: Gross Beta Units: pCi/m T41 T51 T57 T58 T64 End Date T72 (Indicator)

(Indicator) (Indicator) (Indicator) (Indicator) (Control)

LLD 0.07 0.07 0.07 0.07 0.07 0.07 01/07/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 01/15/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 01/21/2020 <0.03 <0.02 <0.02 <0.03 <0.02 <0.02 01/28/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 02/05/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 02/12/2020 <0.02 <0.01 <0.01 <0.01 <0.01 <0.01 02/19/2020 <0.02 <0.01 <0.01 <0.02 <0.02 <0.01 02/25/2020 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 03/03/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 03/10/2020 <0.03 <0.02 <0.02 <0.02 <0.02 <0.02 03/18/2020 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 03/25/2020 <0.03 <0.02 <0.02 <0.03 <0.02 <0.02 04/01/2020 <0.02 <0.01 <0.01 <0.02 <0.01 <0.01 04/08/2020 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 04/13/2020 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 04/22/2020 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 04/29/2020 <0.02 <0.01 <0.02 <0.02 <0.01 <0.02 05/06/2020 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 05/13/2020 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 05/18/2020 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 05/27/2020 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 06/03/2020 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 06/10/2020 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 06/17/2020 <0.02 <0.01 <0.01 <0.01 <0.02 <0.01 06/24/2020 <0.02 <0.02 <0.01 <0.01 <0.01 <0.01 06/30/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 07/07/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 07/13/2020 <0.01 <0.02 <0.02 <0.02 <0.02 <0.02 07/21/2020 <0.01 <0.02 <0.01 <0.02 <0.02 <0.01 07/27/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 08/04/2020 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 08/11/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 08/17/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 08/26/2020 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 09/01/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 09/08/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 09/14/2020 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 09/22/2020 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 09/29/2020 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 10/06/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 10/12/2020 <0.03 <0.03 <0.03 <0.03 <0.02 <0.03 10/19/2020 <0.02 <0.03 <0.03 <0.02 <0.03 <0.02 10/26/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 11/04/2020 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 11/10/2020 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 11/19/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 11/25/2020 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 12/02/2020 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 12/09/2020 <0.01 <0.02 <0.02 <0.01 <0.02 <0.02 12/16/2020 <0.02 <0.02 <0.02 <0.03 <0.04 <0.02 12/23/2020 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 12/29/2020 <0.04 <0.04 <0.04 <0.04 <0.04 <0.04

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 35 of 54 Annual Radiological Environmental Operating Report Attachment 2 Page 4 of 16 Monitoring Results Tables Table 11: Direct Radiation- Indicators Analysis: Gamma Dose Units: mrem/hr st nd rd th 1 Qtr 2 Qtr 3 Qtr 4 Qtr Annual Mean Station 2020 2020 2020 2020 2020 N-2 3.9 4.0 4.7 3.6 4.0 N-7 3.1 3.3 3.8 2.9 3.3 N-10 3.5 3.6 4.3 3.5 3.7 NNW-2 3.4 3.7 3.7 3.3 3.5 NNW-10 3.3 3.8 4.0 3.3 3.6 NW-1 3.7 3.9 4.4 3.5 3.8 NW-5 2.9 3.3 3.7 3.0 3.2 (1)

NW-10 4.0 4.4 4.4 3.8 4.1 WNW-2 3.0 3.5 3.7 3.2 3.4 WNW-10 4.1 4.3 4.4 3.5 4.0 W-1 4.0 3.9 4.1 3.6 3.9 W-5 3.2 3.7 4.1 3.2 3.5 W-9 2.6 3.2 3.6 2.8 3.1 WSW-8 3.3 3.4 3.4 3.0 3.3 SW-1 3.9 3.7 3.7 3.1 3.6 SW-8 2.9 2.9 3.1 2.5 2.8 SSW-5 2.7 3.0 3.2 2.7 2.9 (2)

SSW-10 3.4 3.3 3.6 3.4 S-5 2.9 3.0 3.1 2.6 2.9 S-10 3.7 3.5 3.8 3.1 3.5 SSE-1 2.9 2.9 3.0 2.4 2.8 SSE-10 3.0 3.1 3.0 2.8 3.0 (1)

Indicator station with highest annual mean.

(2) .

See Sample Deviations Table Table 12: Direct Radiation - Control Analysis: Gamma Dose Units: mrem/Hr st nd rd th 1 Qtr 2 Qtr 3 Qtr 4 Qtr Annual Mean Station 2020 2020 2020 2020 2020 NNE-22 3.6 3.8 4.1 3.5 3.7

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 36 of 54 Annual Radiological Environmental Operating Report Attachment 2 Page 5 of 16 Monitoring Results Tables Table 13: Surface Water - Tritium and Gamma Analysis: Gamma Isotopic Units: pCi/L Location End Date H-3 K-40 Location End Date H-3 K-40 Location End Date H-3 K-40 REQUIRED LLD 3,000 -- REQUIRED LLD 3,000 -- REQUIRED LLD 3,000 --

T42 T67 T81 01/07/2020 <140 230 01/06/2020 <138 219 01/07/2020 <140 398 (Indicator) (Control) (Indicator)

T42 T67 T81 02/05/2020 <146 269 02/04/2020 <146 220 02/05/2020 <138 277 (Indicator) (Control) (Indicator)

T42 T67 T81 03/11/2020 <141 287 03/10/2020 <141 304 03/11/2020 <141 308 (Indicator) (Control) (Indicator)

T42 T67 T81 04/10/2020 93 475 04/10/2020 <136 334 04/10/2020 <138 433 (Indicator) (Control) (Indicator)

T42 T67 T81 05/15/2020 <151 435 05/19/2020 <144 186 05/15/2020 <144 420 (Indicator) (Control) (Indicator)

T42 T67 T81 06/16/2020 <137 310 06/17/2020 <137 231 06/16/2020 <137 311 (Indicator) (Control) (Indicator)

T42 T67 T81 07/10/2020 <139 335 07/13/2020 <139 277 07/10/2020 <139 381 (Indicator) (Control) (Indicator)

T42 T67 T81 08/14/2020 <142 372 08/17/2020 <141 265 08/14/2020 <139 332 (Indicator) (Control) (Indicator)

T42 T67 T81 09/11/2020 <139 245 09/14/2020 <139 161 09/11/2020 <139 310 (Indicator) (Control) (Indicator)

T42 T67 T81 10/09/2020 <134 280 10/12/2020 <134 226 10/09/2020 93 323 (Indicator) (Control) (Indicator)

T42 T67 T81 11/24/2020 <139 160 11/25/2020 <139 333 11/24/2020 <139 264 (Indicator) (Control) (Indicator)

T42 T67 T81 12/10/2020 <139 146 12/08/2020 <139 299 12/10/2020 <139 265 (Indicator) (Control) (Indicator)

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 37 of 54 Annual Radiological Environmental Operating Report Attachment 2 Page 6 of 16 Monitoring Results Tables Table 14: Shoreline Sediment - Gamma Analysis: Gamma Isotopic Units: pCi/kg (dry)

Location Collection Date Be-7 K-40 Cs-137 Pb-210 Ra-226 Th-232 U-235 U-238 REQUIRED LLD -- -- 180 -- -- -- -- --

T42 (Indicator) 01/07/2020 <120 92 <11 <1100 556 <49 73 287 T67 (Control) 01/06/2020 <143 826 <13 939 1370 245 182 820 T81 (Indicator) 01/07/2020 <128 308 <11 <1120 681 <52 74 467 T42 (Indicator) 07/10/2020 <110 147 <9 393 466 <39 29 276 T67 (Control) 07/13/2020 <63 104 <5 <292 <183 <26 <12 <86 T81 (Indicator) 07/10/2020 <110 <148 <8 466 481 <38 30 247

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 38 of 54 Annual Radiological Environmental Operating Report Attachment 2 Page 7 of 16 Monitoring Results Tables Table 15: Crustacea - Gamma Analysis: Gamma Isotopic Units: pCi/kg (wet)

Collection Location Sample Type K-40 Ra-226 Ra-228 Date REQUIRED LLD -- -- --

T67 (Control) 03/11/2020 Blue Crab 1480 <64 <102 T81 (Indicator) 05/18/2020 Blue Crab 1650 <346 <82 T67 (Control) 10/22/2020 Blue Crab 1350 370 <110 T81 (Indicator) 10/21/2020 Blue Crab 1400 706 <83

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 39 of 54 Annual Radiological Environmental Operating Report Attachment 2 Page 8 of 16 Monitoring Results Tables Table 16: Fish - Gamma Analysis: Gamma Isotopic Units: pCi/kg (wet)

Collection Location Sample Type K-40 Ra-226 Ra-228 Date REQUIRED LLD -- -- --

T67 (Control) 03/10/2020 Mixed 2020 <44 <73 Species Mixed T81 (Indicator) 03/11/2020 2900 <51 <96 Species Mixed T67 (Control) 10/21/2020 2360 <308 <55 Species Mixed T81 (Indicator) 10/15/2020 3340 <419 <89 Species

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 40 of 54 Annual Radiological Environmental Operating Report Attachment 2 Page 9 of 16 Monitoring Results Tables Table 17: Broad Leaf Vegetation - Gamma Analysis: Gamma Isotopic Units: pCi/kg (wet)

Collection Location Sample Type Be-7 K-40 Cs-137 Pb-210 Pb-212 Ra-226 Date REQUIRED LLD -- -- 80 -- -- --

T40 (Indicator) 01/07/2020 Brazilian Pepper 2300 3690 9 423 <19 <22 T40 (Indicator) 02/05/2020 Brazilian Pepper 3650 4330 <21 <1380 <28 <33 T40 (Indicator) 03/10/2020 Brazilian Pepper 1680 3310 62 877 <24 <33 T40 (Indicator) 04/10/2020 Brazilian Pepper 998 3218 <20 <1034 <28 256 T40 (Indicator) 05/15/2020 Brazilian Pepper 1070 2280 <16 <729 16 <277 T40 (Indicator) 06/17/2020 Brazilian Pepper 2260 5290 <16 764 <24 <298 T40 (Indicator) 07/13/2020 Brazilian Pepper 2320 4950 18 <294 <21 <259 T40 (Indicator) 08/17/2020 Brazilian Pepper 2070 4120 25 <603 <18 <229 T40 (Indicator) 09/14/2020 Brazilian Pepper 1930 4860 78 <301 <23 <263 T40 (Indicator) 10/12/2020 Brazilian Pepper 1660 5190 11 <283 <22 <251 T40 (Indicator) 11/24/2020 Brazilian Pepper 2200 3470 17 289 <18 <202 T40 (Indicator) 12/09/2020 Brazilian Pepper 3480 5090 <17 <942 <26 <301 T41(Indicator) 01/07/2020 Brazilian Pepper 1210 5030 <17 <906 <26 <33 T41(Indicator) 02/05/2020 Brazilian Pepper 1860 5010 <20 <1380 <29 <30 T41(Indicator) 03/10/2020 Brazilian Pepper 1870 4580 <13 <853 <22 <29 T41(Indicator) 04/10/2020 Brazilian Pepper 1260 4620 <17 1239 <29 <349 T41(Indicator) 05/15/2020 Brazilian Pepper 1140 3800 17 <867 <20 <309 T41(Indicator) 06/17/2020 Brazilian Pepper 1430 3940 6 209 <19 <231 T41(Indicator) 07/13/2020 Brazilian Pepper 1010 4870 981 <959 <28 <429 T41(Indicator) 08/17/2020 Brazilian Pepper 1980 5530 <11 <290 <21 129 T41(Indicator) 09/14/2020 Brazilian Pepper 1950 2890 150 <708 <20 <247 T41(Indicator) 10/12/2020 Brazilian Pepper 2150 4330 <10 <625 <18 <227 T41(Indicator) 11/24/2020 Brazilian Pepper 2370 4230 <12 <678 <18 <241 T41(Indicator) 12/10/2020 Brazilian Pepper 1520 3470 <11 <246 <18 <238 T67 (Control) 01/07/2020 Brazilian Pepper 1780 4820 <18 <1130 <27 <33 T67 (Control) 03/04/2020 Brazilian Pepper 1340 5200 <11 <1020 <22 32 T67 (Control) 03/10/2020 Brazilian Pepper 1190 4990 <18 <1050 <27 <32 T67 (Control) 04/10/2020 Brazilian Pepper 1060 4160 <17 <1060 <24 <359 T67 (Control) 05/19/2020 Brazilian Pepper 723 1860 <12 <766 23 <222 T67 (Control) 06/17/2020 Brazilian Pepper 1600 4460 <11 316 <20 <221 T67 (Control) 07/13/2020 Brazilian Pepper 2290 3850 <12 370 <20 <230 T67 (Control) 08/17/2020 Brazilian Pepper 1850 3700 12 356 <18 <208 T67 (Control) 09/14/2020 Brazilian Pepper 1650 2950 27 182 <20 <233 T67 (Control) 10/12/2020 Brazilian Pepper 2000 5720 10 255 <23 <264 T67 (Control) 11/25/2020 Brazilian Pepper 1650 2630 <12 <561 <16 <201 T67 (Control) 12/08/2020 Brazilian Pepper 1040 4470 <13 <684 <21 <231

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 41 of 54 Annual Radiological Environmental Operating Report Attachment 2 Page 10 of 16 Monitoring Results Tables Table 18: Supplemental Direct Radiation- Indicators Analysis: Gamma Dose Units: mrem/hr st nd rd th 1 Qtr 2 Qtr 3 Qtr 4 Qtr Annual Mean Station 2020 2020 2020 2020 2020 NNW-6 3.2 3.5 3.7 3.2 3.4 (1)

NW-7 3.9 4.0 4.1 3.6 3.9 NW-8 3.5 4.1 4.1 3.4 3.8 WNW-3 3.1 3.5 3.6 3.2 3.4 WNW-6 3.2 3.4 3.5 3.0 3.3 W-8 3.5 3.8 4.1 3.4 3.7 ENE-1 3.0 2.9 3.1 2.3 2.8 T72 3.3 3.5 3.8 3.2 3.5 PTN-1 3.2 3.5 3.4 3.2 3.3 (1)

Indicator station with highest annual mean.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 42 of 54 Annual Radiological Environmental Operating Report Page 11 of 16 Monitoring Results Tables Table 19: Supplemental Air Particulate - Gross Beta 3

Analysis: Gross Beta Units: pCi/m (1)

End Date T52 (Indicator) T56 (Indicator)

LLD 0.01 0.01 01/07/2020 0.018 0.015 01/15/2020 0.014 0.013 01/21/2020 0.010 0.013 01/28/2020 0.012 0.015 02/05/2020 0.014 0.013 02/12/2020 0.016 0.010 02/19/2020 0.005 0.008 02/25/2020 <0.009 0.007 03/03/2020 0.010 0.012 03/10/2020 0.009 0.011 03/18/2020 0.004 0.009 03/25/2020 0.007 0.007 04/01/2020 0.011 0.012 04/08/2020 0.023 0.020 04/13/2020 0.027 0.022 04/22/2020 0.015 0.017 04/29/2020 0.015 0.016 05/06/2020 0.014 0.011 05/13/2020 0.017 0.016 05/18/2020 0.009 0.008 05/27/2020 0.015 0.015 06/03/2020 0.010 0.010 06/10/2020 0.004 0.013 06/17/2020 0.011 0.009 06/24/2020 0.008 0.007 06/30/2020 0.009 0.012 07/07/2020 0.012 0.010 07/13/2020 0.021 0.022 07/21/2020 0.012 0.017 07/27/2020 0.005 0.006 08/04/2020 0.010 0.013 08/11/2020 0.010 0.009 08/17/2020 0.009 0.009 08/26/2020 0.012 0.011 09/01/2020 0.007 0.011 09/08/2020 0.019 0.016 09/14/2020 <0.010 0.007 09/22/2020 0.009 0.007 09/29/2020 0.008 0.009 10/06/2020 0.011 0.007 10/12/2020 0.008 0.011 10/19/2020 0.013 0.012 10/26/2020 0.007 0.007 11/04/2020 0.010 0.019 11/10/2020 <0.009 0.004 11/19/2020 0.012 0.009 11/25/2020 <0.007 <0.008 12/02/2020 0.015 0.018 12/09/2020 0.017 0.019 12/16/2020 0.017 0.016 12/23/2020 0.018 0.020 12/29/2020 0.012 0.013 (1)

Station with highest annual mean.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 43 of 54 Annual Radiological Environmental Operating Report Attachment 2 Page 12 of 16 Monitoring Results Tables Table 20: Supplemental Air Particulate Composite - Gamma Analysis: Gamma Isotopic Units: pCi/m 3 Location Collection Date Be-7 K-40 Cs-134 Cs-137 Pb-210 REQUIRED LLD -- -- 0.05 0.06 --

T52 (Indicator) 03/25/2020 0.1090 <0.0132 <0.0013 <0.0008 0.014 T56 (Indicator) 03/25/2020 0.1320 <0.0213 <0.0012 <0.0009 <0.0343 T52 (Indicator) 06/30/2020 0.1390 <0.0215 <0.0010 <0.0010 <0.0317 T56 (Indicator) 06/30/2020 0.1090 <0.0170 <0.0009 <0.0006 <0.0097 T52 (Indicator) 09/29/2020 0.1070 <0.0228 <0.0014 <0.0010 <0.0096 T56 (Indicator) 09/29/2020 0.0937 <0.0173 <0.0008 <0.0007 <0.0094 T52 (Indicator) 12/29/2020 0.1550 <0.0155 <0.0010 <0.0008 <0.0100 T56 (Indicator) 12/29/2020 0.1920 <0.0157 <0.0012 <0.0010 0.0131

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 44 of 54 Annual Radiological Environmental Operating Report Page 13 of 16 Monitoring Results Tables Table 21: Supplemental Air Cartridges - Iodine-131 3

Analysis: Gross Beta Units: pCi/m (1)

End Date T52 (Indicator) T56 (Indicator)

LLD 0.07 0.07 01/07/2020 <0.02 <0.02 01/15/2020 <0.02 <0.02 01/21/2020 <0.02 <0.03 01/28/2020 <0.02 <0.02 02/05/2020 <0.02 <0.02 02/12/2020 <0.02 <0.01 02/19/2020 <0.01 <0.02 02/25/2020 <0.03 <0.03 03/03/2020 <0.02 <0.02 03/10/2020 <0.02 <0.02 03/18/2020 <0.01 <0.01 03/25/2020 <0.02 <0.02 04/01/2020 <0.01 <0.01 04/08/2020 <0.04 <0.03 04/13/2020 <0.03 <0.03 04/22/2020 <0.03 <0.03 04/29/2020 <0.02 <0.01 05/06/2020 <0.03 <0.03 05/13/2020 <0.03 <0.03 05/18/2020 <0.03 <0.03 05/27/2020 <0.02 <0.01 06/03/2020 <0.01 <0.03 06/10/2020 <0.03 <0.03 06/17/2020 <0.03 <0.01 06/24/2020 <0.01 <0.01 06/30/2020 <0.02 <0.02 07/07/2020 <0.01 <0.02 07/13/2020 <0.02 <0.02 07/21/2020 <0.02 <0.02 07/27/2020 <0.02 <0.02 08/04/2020 <0.01 <0.01 08/11/2020 <0.02 <0.02 08/17/2020 <0.02 <0.02 08/26/2020 <0.01 <0.01 09/01/2020 <0.02 <0.02 09/08/2020 <0.02 <0.02 09/14/2020 <0.03 <0.03 09/22/2020 <0.01 <0.01 09/29/2020 <0.03 <0.03 10/06/2020 <0.02 <0.02 10/12/2020 <0.03 <0.03 10/19/2020 <0.02 <0.03 10/26/2020 <0.02 <0.02 11/04/2020 <0.01 <0.01 11/10/2020 <0.03 <0.03 11/19/2020 <0.02 <0.02 11/25/2020 <0.03 <0.03 12/02/2020 <0.02 <0.02 12/09/2020 <0.02 <0.02 12/16/2020 <0.02 <0.02 12/23/2020 <0.02 <0.02 12/29/2020 <0.04 <0.04

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 45 of 54 Annual Radiological Environmental Operating Report Attachment 2 Page 14 of 16 Monitoring Results Tables Table 22: Supplemental Surface Water - Tritium and Gamma Analysis: Gamma Isotopic Units: pCi/L Location End Date H-3 K-40 Location End Date H-3 K-40 Location End Date H-3 K-40 Location End Date H-3 K-40 REQUIRED LLD 3,000 -- REQUIRED LLD 3,000 -- REQUIRED LLD 3,000 -- REQUIRED LLD 3,000 --

T08 T75 T84 T97 (Indicator) 01/07/2020 13455 585 (Indicator) 01/07/2020 <140 <41 (Indicator) 01/07/2020 12468 586 (Indicator) 01/07/2020 12537 584 T08 T75 T84 T97 02/05/2020 10571 569 02/05/2020 <146 <38 02/05/2020 11034 573 02/05/2020 10727 654 (Indicator) (Indicator) (Indicator) (Indicator)

T08 T75 T84 T97 03/11/2020 12904 619 03/09/2020 <141 <86 03/10/2020 14945 682 03/11/2020 13820 671 (Indicator) (Indicator) (Indicator) (Indicator)

T08 T75 T84 T97 04/10/2020 27529 686 04/10/2020 <136 <45 04/10/2020 27099 646 04/10/2020 25519 738 (Indicator) (Indicator) (Indicator) (Indicator)

T08 T75 T84 T97 (Indicator) 05/15/2020 13349 650 (Indicator) 05/15/2020 <144 <88 (Indicator) 05/15/2020 12953 598 (Indicator) 05/15/2020 12759 619 T08 T75 T84 T97 06/16/2020 5456 499 06/17/2020 <137 <42 06/17/2020 5584 560 06/16/2020 5959 437 (Indicator) (Indicator) (Indicator) (Indicator)

T08 T75 T84 T97 07/10/2020 3809 456 07/13/2020 <139 <78 07/10/2020 3525 454 07/10/2020 3438 454 (Indicator) (Indicator) (Indicator) (Indicator)

T08 T75 T84 T97 08/14/2020 3020 439 08/14/2020 <139 <58 08/14/2020 3535 413 08/14/2020 3496 413 (Indicator) (Indicator) (Indicator) (Indicator)

T08 T75 T84 T97 (Indicator) 09/11/2020 3553 487 (Indicator) 09/14/2020 <139 <32 (Indicator) 09/11/2020 3926 421 (Indicator) 09/11/2020 4017 421 T08 T75 T84 T97 10/09/2020 7343 359 10/09/2020 <134 <71 10/09/2020 8129 334 10/09/2020 8114 372 (Indicator) (Indicator) (Indicator) (Indicator)

T08 T75 T84 T97 11/24/2020 5318 349 11/24/2020 <139 <69 11/25/2020 5296 286 11/24/2020 5230 310 (Indicator) (Indicator) (Indicator) (Indicator)

T08 T75 T84 T97 12/10/2020 5112 385 12/10/2020 <139 <61 12/10/2020 5051 290 12/10/2020 4826 315 (Indicator) (Indicator) (Indicator) (Indicator)

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 46 of 54 Annual Radiological Environmental Operating Report Attachment 2 Page 15 of 16 Monitoring Results Tables Table 23: Supplemental Shoreline Sediment - Gamma Analysis: Gamma Isotopic Units: pCi/kg (dry)

Location Collection Date Be-7 K-40 Cs-137 Pb-210 Ra-226 Th-232 U-235 U-238 REQUIRED LLD -- -- 180 -- -- -- -- --

T01 (Indicator) 01/07/2020 <145 494 <12 805 797 <57 86 193 T02 (Indicator) 01/07/2020 <154 814 12 <1380 851 <80 111 339 T03 (Indicator) 01/07/2020 <257 2940 110 4660 2620 215 266 974 T04 (Indicator) 01/07/2020 619 681 11 1100 769 <59 81 492 T07 (Indicator) 01/07/2020 <129 578 24 673 846 <60 64 278 T08 (Indicator) 01/07/2020 <133 912 15 1100 788 61 96 319 T10 (Indicator) 01/07/2020 <199 871 <20 <1660 760 <90 <29 <325 T84* (Indicator) 01/07/2020 71 599 <15 2140 1510 61 146 503 T85* (Indicator) 01/07/2020 <133 690 <11 863 996 65 113 696 T84* (Indicator) 07/10/2020 <148 531 <13 2420 1370 <67 86 173 T85* (Indicator) 07/10/2020 <126 560 9 633 837 <87 53 245

  • Note that site T48 is the same location as site T05, and site T85 is the same location as site T06.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 47 of 54 Annual Radiological Environmental Operating Report Attachment 2 Page 16 of 16 Monitoring Results Tables Table 24: Supplemental Broad Leaf Vegetation - Gamma Analysis: Gamma Isotopic Units: pCi/kg (wet)

Collection Location Sample Type Be-7 K-40 Cs-137 Ra-226 Date REQUIRED LLD -- -- 80 --

T43 (Indicator) 01/07/2020 Corn <68 3130 <8 <14 T44 (Indicator) 02/11/2020 Corn <55 2230 <7 <14 T45 (Indicator) 04/08/2020 Green String Beans <136 2348 <18 <337

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 48 of 54 Annual Radiological Environmental Operating Report Attachment 3 Page 1 of 3 Interlaboratory Comparison Program Results 1.0 Summary The Interlaboratory Comparison Program consists of participating in the DOE Mixed Analyte Performance Evaluation Program (MAPEP).

This program provides similar testing (matrices, nuclides, and levels) as the former EPA Interlaboratory Comparison Program and is referred to as the Mixed Analyte Performance Evaluation Program (MAPEP).

The samples are analyzed using the methods applicable to the REMP (gamma spectroscopy, Gross Beta, and Tritium for water).

From the MAPEP handbook:

Acceptance criteria were developed from a review of precision and accuracy data compiled by other performance evaluation programs (PEPs), the analytical methods literature, from several MAPEP pilot studies, and from what is considered reasonable, acceptable, and achievable for routine analyses among the more experienced laboratories.

The State laboratory participated in MAPEP 42 and 43. These satisfied the requirement of Control 5.3 of the ODCM for the Interlaboratory Comparison Program.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 49 of 54 Annual Radiological Environmental Operating Report Attachment 3 Page 2 of 3 Interlaboratory Comparison Program Results Table 25: DOEs Mixed Analyte Performance Evaluation Program (MAPEP) 42 RESULTS Program Ref. Flag Acceptance Result status Radionuclide Value (Evaluation) Range Matrix: RdF Air Filter Bq/filter Required MN54 0.001 A False Positive Test Required CO57 1.523 1.50 A 1.05-1.95 Required CO60 1.270 1.23 A 0.86-1.60 ZN65 1.380 1.18 A 0.83-1.53 Required CS134 0.585 0.600 A 0.420-0.780 Required CS137 0.766 0.735 A 0.515-0.956 Matrix: GrF Air Filter Bq/filter Required Gross Beta 2.13 2.00 A 1.00-3.00 Gross Required 1.71 1.24 A 0.37-2.11 Alpha Matrix: MaS Soil Bq/kg Required K40 652.00 625 A 438-813 MN54 980.20 945 A 662-1229 CO57 994.20 1071 A 750-1392 CO60 0.87 A False Positive Test ZN65 804.80 751 A 526-976 CS134 1166.54 1114 A 780-1448 Required CS137 1054.0 1020 A 714-1326 Matrix: MaW Water Bq/L Required H3 211.43 196 A 137-255 MN54 19.95 19.6 A 13.7-25.5 CO57 19.08 19.7 A 13.8-25.6 Required CO60 10.45 10.6 A 7.4-13.8 ZN65 22.120 22.2 A 15.5-28.9 Required CS134 17.547 18.5 A 13.0-24.1 Required CS137 11.68 11.3 A 7.9-14.7 SR90 -0.028 A False Positive Test Matrix: RdV Vegetation, Bq/sample MN54 4.867 4.58 A 3.21-5.95 CO57 -0.011 A False Positive Test Required CO60 2.733 2.79 A 1.95-3.63 ZN65 3.983 3.79 A 2.65-4.93 CS134 3.664 3.82 A 2.67-4.97 Required CS137 2.867 2.77 A 1.94-3.60 Evaluation: A = Acceptable, W = Acceptable with Warning, N = Not Acceptable, NR = Not Reported A false positive test with an A designation flag identifies the result as less than the detectable activity, since MAPEP does not report zero values. Sensitivity Evaluation has no acceptance range but an identified value at low activity.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 50 of 54 Annual Radiological Environmental Operating Report Attachment 3 Page 3 of 3 Interlaboratory Comparison Program Results Table 26: DOEs Mixed Analyte Performance Evaluation Program (MAPEP) 43 RESULTS Program Ref. Flag Acceptance Result status Radionuclide Value (Evaluation) Range Matrix: RdF Air Filter Bq/filter Required MN54 1.433 1.40 A 0.98 - 1.82 Required CO57 0.005 A False Positive Test Required CO60 1.632 1.73 A 1.21 - 2.25 ZN65 2.117 2.00 A 1.40 - 2.60 Required CS134 1.561 1.83 A 1.28 - 2.38 Required CS137 0.944 0.996 A 0.697 - 1.295 Matrix: GrF Air Filter Bq/filter Required Gross Beta 1.022 0.915 A 0.458 - 1.373 Gross Required 0.549 0.528 A 0.158 - 0.898 Alpha Matrix: MaS Soil Bq/kg Required K40 573.94 622 A 435 - 809 MN54 579.44 610 A 427 - 793 CO57 936.42 1100 A 770 - 1430 CO60 925.00 1000 A 700 - 1300 ZN65 448.06 470 A 329 - 611 CS134 682.26 710 A 497 - 923 Required CS137 0.80 A False Positive Test Matrix: MaW Water Bq/L Required H3 381.57 360 A 252 - 468 MN54 0.010 A False Positive Test CO57 -0.015 A False Positive Test Required CO60 11.612 12.2 A 8.5 - 15.9 ZN65 17.212 16.9 A 11.8 - 22.0 Required CS134 13.549 15.2 A 10.6 - 19.8 Required CS137 14.268 14.3 A 10.0 - 18.6 SR90 11.468 11.6 A 8.1 - 15.1 Matrix: RdV Vegetation, Bq/sample:

MN54 6.261 5.84 A 4.09 - 7.59 CO57 7.992 6.67 A 4.67 - 8.67 Required CO60 4.425 4.13 A 2.89 - 5.37 ZN65 7.075 6.38 A 4.47 - 8.29 CS134 4.911 4.94 A 3.46 - 6.42 Required CS137 0.028 A False Positive Test Evaluation: A = Acceptable, W = Acceptable with Warning, N = Not Acceptable, NR = Not Reported A false positive test with an A designation flag identifies the result as less than the detectable activity, since MAPEP does not report zero values. Sensitivity Evaluation has no acceptance range but an identified value at low activity.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 51 of 54 Annual Radiological Environmental Operating Report Attachment 4 Page 1 of 4 Industry Initiative Ground Water Protection Program 2020 1.0 Description of Program Turkey Point Nuclear maintains a sampling and analysis program to meet procedural requirements.

The procedures that govern the performance are EV-AA-100-1001, Fleet Ground Water Protection Program Implementing Guideline and 0-ADM-654, Ground Water Protection Program.

The sampling frequency is quarterly; more often if conditions warrant.

Sample assay is performed by a private contractor GEL lab.

2.0 Discussion The Turkey Point Nuclear site is surrounded on three sides by the closed cooling canal system.

This canal system, in addition to being the source of tertiary cooling, is the body of water receiving permitted liquid radiological waste the canal system tritium level averages was 9317 pCi/L in 2020 with a max concentration of 27,529 pCi/L. This supports the expectation to see tritium in subsurface water collected either on-site or off-site close to the (within the Owner Controlled Area) cooling canal system. Twenty-eight (28) wells were involved in the 2020 monitoring program; some locations have multiple (two or three) depths.

Samples are analyzed for Tritium & Gamma emitters. As conditions warrant, analysis included Fe-55, Ni-63, Sr-89/90 and alpha (all were < LLD).

3.0 Results The tritium results for the groundwater wells were from <MDA to 9380 pCi/L. All results were less than the limits of the Offsite Dose Calculation Manual, Table 5.1-2, Reporting Levels for Radioactivity Concentrations in Environmental Samples. Storm drain outfalls occasionally are below the tidal mark of the canal and will have ingress of canal water into the storm drain. The higher levels of tritium in the storm drain section are due to the canal water ingress into the storm drain.

Tabular results follow:

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 52 of 54 Annual Radiological Environmental Operating Report Attachment 4 Page 2 of 4 Monitoring Results Tables Table 27: Ground Water - Tritium Analysis: Tritium Units: pCi/L First Quarter Second Quarter Third Quarter Fourth Quarter Location 2020 2020 2020 2020 H-3 H-3 H-3 H-3 REQUIRED LLD 3,000 3,000 3,000 3,000 PTPED-1 237 270 101 101 CD-1 327 399 50 50 P-94-2 --- 577 529 ---

P-94-4 554 395 529 529 STP-1 --- 52 84 ---

PTN-MW-1s --- 4 244 ---

PTN-MW-1i --- 232 197 ---

PTN-MW-1d --- 1670 1410 ---

PTN-MW-2s --- 143 25 ---

PTN-MW-3s --- 37 66 ---

PTN-MW-4s 80 88 45 45 PTN-MW-4i -95 35 1610 -17 PTN-MW-4d -6 1 45 6 PTN-MW-5s --- 209 951 951 PTN-MW-5i 208 334 136 89 PTN-MW-5d 1810 1590 1500 1500 PTN-MW-6s --- -83 -90 ---

PTN-MW-6i --- --- --- ---

PTN-MW-6d --- 1180 1340 ---

PTN-MW-7s 563 613 564 434 PTN-MW-7i 528 762 35.2 -57 PTN-MW-7d 27 125 151 120 PTN-MW-8s 4200 1760 2100 1300 PTN-MW-9s 633 1760 2100 843 PTN-MW-10s --- -2 -43 ---

PTN-MW-10i --- 643 923 ---

PTN-MW-10d --- 16 44 ---

PTN-MW-11s 58 106 94 94 PTN-MW-12s 726 470 582 582 NE StrmDrain 534 8240 612 1630 SE StrmDrain 9380 113 dry 5050 W StrmDrain 346 343 1570 4970 CRF StrmDrain dry dry dry dry

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 53 of 54 Annual Radiological Environmental Operating Report Attachment 4 Page 3 of 4 Industry Initiative Ground Water Protection Program 2020 D. List of wells and their locations Well Name Location PTN-MW-1s PTN-MW-1i Northeast of Switch Yard, South of entrance road to Fossil Plant PTN-MW-1d PTN-MW-2s South Switch Yard by parking lot PTN-MW-3s Northeast of new Issues Warehouse PTN-MW-4s PTN-MW-4i SW corner of parking lot South of Training Bldg.

PTN-MW-4d PTN-MW-5s PTN-MW-5i SW of CRF, by canal PTN-MW-5d PTN-MW-6s NE of site in the berm for fossil oil tanks PTN-MW-6d PTN-MW-7s PTN-MW-7i NE of RCA, by Neutralization Tank PTN-MW-7d PTN-MW-8s Near U3 RWST PTN-MW-9s Near U4 RWST PTN-MW-10s PTN-MW-10i SE of Radwaste Bldg. by S/G Bldg.

PTN-MW-10d PTN-MW-11s South of truck entrance to Rad Waste Bldg.

PTN-MW-12s West of Condenser Polisher road STP-1 West of Maintenance Bldg. on corner or road into parking lot P-94-4 East of Dressout Building, under delay fence P-94-2 By Neutralization Basin, East of the RCA CD-1 By Neutralization Basin, East of the RCA PTPED-1 By Neutralization Basin, East of the RCA Note: s, i and d refer to well depth: shallow - 20 ft., intermediate - 40 ft. and deep - 60 ft Maps depicting the well locations follow.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2020 Page 54 of 54 Annual Radiological Environmental Operating Report Page 4 of 4 Industry Initiative Ground Water Protection Program 2020 Figure 5: Onsite Tritium Monitoring Wells