ML21130A284
| ML21130A284 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 04/21/2021 |
| From: | Nebraska Public Power District (NPPD) |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML21130A114 | List:
|
| References | |
| NLS2021013 | |
| Download: ML21130A284 (1) | |
Text
1 A
B C
D E
F G
H
(/)
z 0
U)
~
J 0:::
ci z
1 2
2 POWER AVAILABLE REF PERMISSIVE WHEN REFUEL PLATFORM NOT OVER CORE AREA 11 3
3 POSITION INDICATOR PROBE (INSERT SWITCHES)
REF 7 CHANNEL A PERMISSIVE WHEN ALL RODS ARE IN SH 1, E-2 PERMISSIVE WHEN SELECTED ROD ENABLED SH 3, H-3 PERMISSIVE WHEN GRAPPLE IN FULL-UP POSITION PERMISSIVE WHEN GRAPPLE NOT FUEL LOADED (LOAD <400 LB)
PERMISSIVE WHEN FRAME HOIST NOT FUEL LOADED (LOAD <400 LB)
PERMISSIVE WHEN TROLLEY HOIST NOT FUEL LOADED (LOAD <400 LB)
PERMISSIVE WHEN SERVICE PLATFORM HOIST NOT FUEL LOADED (LOAD <400
+/- 50 LB) 4 4
CHANNEL A REFUEL MODE ON ROD CONTROL JS PERMISSIVE D-3 CHANNEL A REFUEL MODE ONE ROD CONTROL C-4, F-6 SH 3, F-1, G-4 SH 6, E-2, G-3 (REACTOR SYS MODE SWITCH)
PERMISSIVE WHEN RUN SWITCH IS ON RMS X
REF 11 5
REF PERMISSIVE WHEN REFUEL PLATFORM NOT OVER CORE AREA 5
11 6
POSITION INDICATOR PROBE (INSERT SWITCHES)
REF 7 CHANNEL B PERMISSIVE WHEN ALL RODS ARE IN SH 1, E-2 PERMISSIVE WHEN SELECTED ROD ENABLED SH 3, H-3 REACTOR SYS MODE WITCH) PERMISSIVE WHEN SHUTDOWN REFUEL OR RUN SWITCH IS ON RMS X
REF 11 CHANNEL A REFUEL MODE ONE ROD CONTROL IS PERMISSIVE D-3 CHANNEL B REFUEL MODE ONE ROD CONTROL IS PERMISSIVE D-6 PERMISSIVE WHEN SERVICE PLATFORM HOIST NOT FUEL LOADED (LOAD <400
+/- 50 LB)
CHANNEL B REFUEL MODE ON ROD CONTROL JS PERMISSIVE D-6 CHANNEL B REFUEL MODE ONE ROD CONTROL C-7, F-6 SH 3, F-1, G-5 SH 6, D-2, H-4 (REACTOR SYS MODE SWITCH)
PERMISSIVE WHEN RUN SWITCH IS ON RMS X
REF 11 8
9 I
REF 11 DISCHARGE VOLUME HIGH WATER LEVEL ROD BLOCK D500, 564 D501, 565 D502, 566 D503, 567 CHANNEL A ANNUNCIATING ROD BLOCK CONTROL SH 3, C-5 SH 4, B-2 RWM WITHDRAW CONTROL IS PERMISSIVE PERMISSIVE WHEN BOTH AUX INPUTS ARE PRESENT 10 SH 7, G-8
,cR,.
A WITHDRAW NON
, PERMISSIVE
~------~~SH 3, E-7 NON-ANNUCIATING ROD BLOCK CONTROL CR A
ROD OUT BLOCK RPSRBA C1650 SH 4, E-4 1 1 7
REF 11 CHANNEL B SH 3, C-5 ANNUNCIATING SH 4, B-2 ROD BLOCK CONTROL
- THIS DRAWING GENERATED BY NPPD
- FOR PREVIOUS REVISIONS, SEE SUPERSEDED CARDS.
SIGNIFICANT NUMBER GROUP 2
3 4
5 6
COOPER NUCLEAR STATION
- N02 REV & REDRAWN PER APA DCN C93-1577 DR JAC SJT 11-16-93 FUNCTIONAL CONTROL DIAGRAM NO.
REVISIONS DFT CKD APP DATE CONTROL ROD DRIVE HYDRAULIC SYSTEM DCN REVISIONS BY N.P.P.D.
6 8
9 10 1 1 12 INFORMATION ONLY NOTES:
1,
FOR GENERAL NOTES AND REFERENCE DOCUMENTS SEE SHEET 1,
452005836 DRAWN DATE DR 10-18-93 GENERAL CHECKED DATE APPROVED DATE ELECTRIC*
SJT 11-16-93 FILMED REVISION 729E47188 SH. 5 N02 12
~
Ii:
~
A B
C D
E F
G H
-,j-OCl 0
J 0
0
(.)