1 A
B C
D E
F G
H J
ci
- z 1
2 CONTROL ROD WITHDRAW RPSCW (NOT IN PMIS)
C1841 CR
/
ANNUNCIATING ROD WITHDRAW BLOCK CONTROL IS PERMISSIVE (CHANNELS A & B)
SH 5, H-9, H-10 PERMISSIVE AFTER TIME DELAY OF 0.85 SEC TABLE 1, SH 1 PERMISSIVE FOR TIME DELAY OF 1.50 SEC TABLE 1, SH 1 PERMISSIVE WHEN INSERT BUS IS NOT ENERGIZED G-7 ROD WITHDRAW CONTROL C-3 SH 3, C-4 (ROD OUT NOTCH OVERRIDE SWITCH)
PERMISSIVE WHEN EMERGENCY ROD IN SWITCH IS NOT ON RMS SH 1, 8-7 3
ROD WITHDRAW CONTROL IS PERMISSIVE 4
SELECT WITH-DRAW CONTROL IS PERMISSIVE 5
CONTINUOUS WITHDRAW CONTROL IS PERMISSIVE AFTER TIME DELAY OF 1.05 SEC NOT PERMISSIVE D-3 CONTINUOUS WITHDRAW CONTROL IS PERMISSIVE F-4 (ROD MOVEMENT CONTROL SWITCH)
PERMISSIVE WHEN ROD OUT NOTCH SWITCH IS ON RMS X
SH 3, C-7 (ROD OUT NOTCH OVERRIDE SWITCH)
PERMISSIVE WHEN NOTCH OVERRIDE SWITCH IS ON RMS X
SH 1, B-7 NON-ANNUNCIATING ROD WITHDRAW BLOCK CONTROL IS PERMISSIVE PERMISSIVE WHEN RPIS SH 5, G-10 HAS NOT MALFUNCTIONED PERMISSIVE FOR TIME DELAY OF 7.3 SEC CR CONTINUOUS WITHDRAW CONTROL C-3, C-6, E-5, B-6 SH 3, C-4, F-9, E-8 SH 1, E-1
/
1-------1 A
/
NOTCH OVERRIDE TABLE 1, SH 1 TABLE 1, SH 1 CONTINUOUS WITH-DRAW CONTROL IS NOT PERMISSIVE F-4 SETTLE CONTROL CR
/
A
/
SETTLE BUS ENERGIZED F-4 R 1----------l
/
WITHDRAW BUS ENERGIZED 2
WITHDRAW BUS SH 2, A-9 PERMISSIVE WHEN SELECTED ROD ENABLED SH 3, H-3 WITHDRAW SOLENOID VALVE OPEN WHEN ENERGIZED S0-122 LOCAL TYP FOR EACH ROD DRIVE REF 1 3
NOTE 1, SH I WITHDRAW CONTROL 4
WITHDRAW &
SETTLE BUS PERMISSIVE WHEN SELECTED ROD ENABLED SH 3, H-3 WITHDRAW &
SETTLE SOLENOID VALVE OPEN WHEN ENERGIZED S0-120 LOCAL TYP FOR EACH ROD DRIVE REF 1 5
6 CONTINUOUS WITHDRAW CONTROL IS PERMISSIVE F-4 CONTINUOUS INSERT CONTROL IS NOT PERMISSIVE F-8 PERMISSIVE AFTER TIME DELAY OF 0.2 SEC PERMISSIVE FOR TIME DELAY OF 0.65 SEC TABLE 1. SH 1 TABLE 1, SH 1 UNLATCH CONTROL CONTINUOUS INSERT 8
PERMISSIVE AFTER TIME DELAY OF 2.0 SEC PERMISSIVE FOR TIME DELAY OF 5.8 SEC TABLE 1. SH 1 TABLE 1, SH 1 (ROD MOVEMENT CONTROL SWITCH PERMISSIVE WHEN ROD IN SWITCH IS ON RMS RWM INSERT CONTROL X
SH 3, B-10 IS PERMISSIVE PERMISSIVE WHEN RPIS SH 7, G-11 HAS NOT MALFUNCTIONED CONTROL B-8, C-9, C-10, E-6 SH 3, F-12, E-11 SH 1, E-1 INSERT BUS E-2 9
SELECT INSERT CONTROL IS PERMISSIVE CONTINUOUS INSERT CONTROL IS NOT PERMISSIVE F-8 CR
/
CONTINUOUS INSERT CONTROL IS PERMISSIVE G
INSERT BUS
, ENERGIZED F-8 10 PERMISSIVE AFTER TIME DELAY OF 0.4 SEC PERMISSIVE FOR TIME DELAY OF 2.9 SEC TABLE 1, SH 1 TABLE 1, SH 1 ROD INSERT CONTROL 1 1 CONTINUOUS INSERT CONTROL IS PERMISSIVE POWER AVAILABLE RWM INSERT CONTROL F-8 IS PERMISSIVE SH 7, G-11 (ROD OUT NOTCH OVERRIDE SWITCH)
PERMISSIVE WHEN EMERGENCY ROD IN SWITCH IS ON RMS X
SH 1, B-7 EMERGENCY ROD INSERT CONTROL 12 NOTE 1, SH 1 SH 3, B-5 SH 2, A-10 PERMISSIVE WHEN SELECTED ROD ENABLED NOTE I, SH 1 INSERT SOLENOID VALVE OPEN WHEN ENERGIZED S0-121 LOCAL SH 3, H-3 TYP FOR EACH ROD DRIVE REF 1 INSERT CONTROL
- FOR PREVIOUS REVISIONS, SEE SUPERSEDED CARDS.
REVISIONS DCN REVISIONS BY N.P.P.D.
6 8
INFORMATION ONLY INSERT SOLENOID VALVE OPEN WHEN ENERGIZED NOTES:
S0-123 LOCAL FOR GENERAL NOTES AND REFERENCE DOCUMENTS SEE SHEET 1.
- THIS DRAWING GENERATED BY NPPD SIGNIFICANT NUMBER GROUP COOPER 2
3 NUCLEAR 4
5 6
STATION FUNCTIONAL CONTROL DIAGRAM CONTROL ROD DRIVE HYDRAULIC SYSTEM 9
10 1 1 DRAWN DR CHECKED JAC APPROVED AGB FILMED 452005835 CADD DRAWING DO NOT REVISE MANUALLY DATE 11-5-93 GENERAL DATE t')
11-10-93 CX)
ELECTRIC*
0 DATE 0
11-23-93 0
~ u REVISION Ii:
729E47188 SH. 4 N01
~
12 A
B C
D E
F G
H J