L
(/J z:
0 vi i:;:j c:::
(/J z:
0 vi c:::
w ci z:
U.G. TO NEW __...---+ 72-D MET TOWER TO CORNFIELD SUB OPA-XFMR-BLDG102
12.5KV
'<-Q
\\ '
PAVED PARKING AREA TSB WEST PARKING 12.5KV_-i::::::;:::i JUNCTION MODULE U.G. TO MET TOWER TECH SUPPORT BUILDING 2-4" 3-1/0 CU UG TRAINING CENTER 1 -1 /0 ACSR SHIELD, 3-795 ACSR PR!.
12.5/7.2KV WITH 1/0 ACSR NEUT.
CRAFT CHANGE BUILDING NOR LOAD CTR TO FIRE TRAINING AREA AND OLD SHOOTING RANGE TO N. WAREHOUSE RANSF.
I '
E fz-2.4" I
I.if.:.
c.d I
=> I FAB F. P.
PUMP HOUSE 0
Q-...l 1-----u SHOP
---;I
- Fl;EX;
- ;ST;;O:;.RAG~E i:* I BUILDINGJL Q, J 2_ 3,,
NORTH SWGR.
g-~:~-4~A!:;_U~:_ _ _::~:\\_---
MPF EE-XFMR-LPFS I
2-6" v,aoo I
I I
I I
I I
I 1
1 1
EAST/
SWGR.
2-4 KCM AL U.G.
SCALE IN FEET 1" = 100'-Q" JUNCTION --+---t---+-
j
"-.!OTE.-:
3 4 !5 KV SWITCH YA RO I.
Al... T&..R.NATE. L OCA.. TiON Foe lf-JSTALLA 110"-l OF u,~-IZ..5 KV MOBILE. sui3 -
PRE..F' e_i::ii::f!.t:)
LOCATION JS THE:'
COR't-J Fl E..l...D SUB. '5 I TE. _ 5 E.E.
ND eoz B~Z. f"Ol< DE..T.A..IL:S.
REF. DW5. NC 66121 D PULL BOX 181 SWITCH GEAR
~
SWITCH GEAR MODULE J:;,iZ;. PAO MTO. TRANSFORMER 8
RISER POLE TERMINATOR 345KV OEAOENO TOWER 2-4" 4-4" 1-2" 3-1/0 CU UG
\\_4*' ~
3-1/0 CU UG 12.5KV JUNCTION MODULE PARKING AREA AUGMENTED RADWASTE BUILDING RAOWASTE BJILDING CONTROL BUILDING 3-1/0 CU UG IT SHACK U)
C) wz o-UG i:: ~
TURBINE-GENERATOR BUILDING 161 KV SWITCHVARO 12.5KV JUNCTION MODULE__...e:=-+---1 2-4 3-1/0 cu WHSE.
EXT.
i..-
o:::i m
2-4" 7-500MCM 1-4/0 CU UG SOUTH LOAD CTR. a AOMIN. BLOG. TRF.
WAREHOUSE DINING HALL 3-1/0 AL UG NPPD JOINT USE DRAWING THIS DRAWING PERTAINS TO MULTIPLE LAB/OFFICES AND D!Rs. UPDATES SHALL BE RECORDED ON THE PRIMARY DIR WITH PRIMARY LAB/OFFICE APPROVAL. THE SECONDARY DIR SHALL THEN BE VERSIONED BY A DOCUMENT MANAGER.
SECONDARY DIR:
492044587 SIGNIFICANT NUMBER 930096 REACTOR BUILDING ADHR SUBSTATION EE-XFMR-ADHR TRANSFORMER YARD 69KV TURN TOWER SOUTH SWGR MACHINE SHOP tfZ:.
EE-XFMR-SAWDECK=/
2-6" O
COND.
STORAGE TANK SKE-DDS 062381 2590 FOR PREVIOUS REVISIONS, SEE SUPERSEDED CARDS.
GROUP 2
3 4
5 6
VERSIONS/REVISIONS BY N.P.P.D.
NO.
DESCRIPTION OFT DATE ENG AC 16 DR-2014-0008 AE 17 DR-2014-0008 AD 18 DR-2013-0985 COOPER NUCLEAR STATION ROUTING OF 12.5 KV UNDERGROUND SYSTEM INTAKE STRUCnJRE INTAKE TRANSf.
STR. I i
I I
SLUDGE POND DRAWN DJF CHECKED WWW APPROVED GRK FILMED 9/10/81 AS BOTn.E STORAGE I
MISSOURI RIVER EL. 89~0 I
I
- I
\\
II,
\\
l I
- j I
DATE 6-23-81 DATE 8-28-81 DATE 8/28/81 AS BUILT 452206377 STATUS: Release STATUS DATE: 01/29/2016 DS APPROVED: DWHELMI VER: AD REV: 18 SIZE: C H
-.;I-N 0
Nebraska Public Power District I")
N 0
0 w w
.J NC44587 C, 5