ML21130A228
| ML21130A228 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 04/21/2021 |
| From: | Nebraska Public Power District (NPPD) |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML21130A114 | List:
|
| References | |
| NLS2021013 | |
| Download: ML21130A228 (1) | |
Text
1 A
B C
D E
F G
H J
ci
- z 1
POWER AVAILABLE (ROD SELECT POWER SWITCH)
PERMISSIVE WHEN SWITCH IS ON RMS PERMISSIVE WHEN RMS CR HAS NOT MALFUNCTIONED SH 1, E-1 PERMISSIVE IF ROD TIMING CONTROL HAS NOT MALFUNCTIONED 2
SELECT WITHDRAW CONTROL IS PERMISSIVE G-7 PERMISSIVE WHEN SELECTED ROD IS ENABLED H-3 (ROD OUT NOTCH OVERRIDE SWITCH)
PERMISSIVE WHEN EMERGENCY ROD IN SWITCH IS ON RMS X
SH 1, B-7 3
SELECT INSERT CONTROL IS PERMISSIVE G-10 4
ROD WITHDRAW CONTROL IS PERMISSIVE 5
POWER AVAILABLE PERMISSIVE WHEN INSERT BUS IS NOT ENERGIZED SH 4, G-7 SH 4, D-2 CONTINUOUS WITHDRAW CONTROL IS NOT PERMISSIVE SH 4, F-4 ANNUNCIATING ROD WITHDRAW BLOCK CONTROL IS NOT PERMISSIVE (CHANNELS A & B)
SH 5, H-9, H-10 PERMISSIVE AFTER TIME DELAY OF 2 +.05 SEC
-0,0 TIMER TEST SWITCH PERMISSIVE WHEN TEST SWITCH IS ON RMS CR 6
E-5 SELECT WITH-DRAW CONTROL IS NOT PERMISSIVE G-7 SELECT INSERT CONTROL IS NOT PERMISSIVE G-10 ROD MOVEMENT CONTROL SWITCH PERMISSIVE WHEN ROD OUT SWITCH IS ON RMS CR C-11, D-8, D-11 SH 4, D-4 PERMISSIVE FOR TIME DELAY OF 1 +1 SEC
-0 ROD MOVEMENT CONTROL SWITCH PERMISSIVE WHEN ROD IN SWITCH IS ON RMS B-7 PERMISSIVE WHEN SELECT INSERT CONTROL IS NOT PERMISSIVE G-10 NON-ANNUNCIATIN ROD WITHDRAW BLOCK CONTROL IS PERMISSIVE 8
SELECT WITH-DRAW CONTROL IS PERMISSIVE G-7 9
(ROD OUT NOTCH OVERRIDE SWITCH)
PERMISSIVE WHEN EMERGENCY ROD IN SWITCH IS NOT ON RMS SH 1, 8-7 10 ROD MOVEMENT CONTROL SWITCH PERMISSIVE WHEN ROD IN SWITCH IS ON RMS CR B-7 SH 4, E-8 PERMISSIVE FOR TIME DELAY OF 1 +1 SEC
-0 ROD MOVEMENT CONTROL SWITCH PERMISSIVE WHEN ROD OUT NOTCH SWITCH IS ON RMS B-7 PERMISSIVE WHEN SELECT WITHDRAW CONTROL IS NOT PERMISSIVE RWM INSERT CONTROL JS PERMISSIVE G-7 1 1 SELECT INSERT CONTROL IS PERMISSIVE G-10 12 (CONTROL ROD &
SELECT PB) PERM.
WHEN CONTROL ROD SELECTED BY OPERATOR C
CONTROL ROD TIMER MALFUNCTION RPSCTF
~t---------1 rrL._ ___
~
SH 5, G-10 SH 7, G-11 RMS CHANNEL A REFUEL MODE X
ONE ROD CONTROL NOT PERMISSIVE SH 1, 8-3 NOTE 1, SH SH 5, D-3 CHANNEL B REFUEL MODE ONE ROD CONTROL NOT PERMISSIVE SH 5, D-6 SELECT WITHDRAW CONTROL IS NOT PERMISSIVE G-7 SELECT INSERT CONTROL IS NOT PERMISSIVE G-10 2
SELECT WITHDRAW CONTROL IS PERMISSIVE G-7 PERMISSIVE WHEN SELECTED ROD ENABLED H-3 SELECTED ROD ENABLED 3
C1604 SELECT INSERT CONTROL IS PERMISSIVE G-10 C-2, G-3 CHANNEL A REFUEL MODE ONE ROD CONTROL IS PERMISSIVE SH 5, D-3 SH 1, A-7, 8-3 SH 4, G-3, G-5, G-8 SH 5, C-3, C-6 SH 7, C-11 4
(TIMER TEST SWITCH)
PERMISSIVE WHEN RESET SWITCH IS NOT ON RMS CR CHANNEL B REFUEL MODE C-5 ONE ROD CONTROL NOT PERMISSIVE SH 5, D-6 5
PERMISSIVE FOR TIME DELAY OF 9.8 SEC TABLE 1, SH 1 SELECT WITH-DRAW CONTROL PERMISSIVE FOR TIME DELAY OF 6.5 SEC TABLE 1, SH 1 CONTINUOUS WITHDRAW CONTROL IS NOT PERMISSIVE SH 4, F-4 B-2, C-5, C-8, F-2, D-10, G-2 SH 1, A-8 CONTINUOUS WITHDRAW CONTROL IS PERMISSIVE SH 4, F-4 PERMISSIVE FOR TIME DELAY OF 9.0 SEC TABLE I, SH 1 SELECT INSERT CONTROL PERMISSIVE FOR TIME DELAY OF 5.0 SEC TABLE 1, SH 1 CONTINUOUS INSERT CONTROL IS NOT PERMISSIVE SH 4, F-8 B-3, D-5, D-7, F-3, C-11, G-2 SH 1, A-8 NOTES:
CONTINUOUS INSERT CONTROL IS PERMISSIVE SH 4, F-8
- 1. FOR GENERAL NOTES AND REFERENCE DOCUMENTS SEE SHEET 1.
- FOR PREVIOUS REVISIONS, SEE SUPERSEDED CARDS.
REVISIONS DCN REVISIONS BY N.P.P.D.
6 8
INFORMATION ONLY
- THIS DRAWING GENERATED BY NPPD SIGNIFICANT NUMBER GROUP COOPER 2
3 NUCLEAR 4
5 6
STATION FUNCTIONAL CONTROL DIAGRAM CONTROL ROD DRIVE HYDRAULIC SYSTEM 9
10 1 1 452005834 CADD DRAWING DO NOT REVISE MANUALLY DRAWN DATE DR 10-29-93 GENERAL CHECKED DATE N
JAC 11-9-93 CX)
ELECTRIC*
0 APPROVED DATE 0
AGB 11-23-93 0
~ u FILMED REVISION Ii:
729E47188 SH. 3 N02 ~
12 A
B C
D E
F G
H J