0 to Updated Final Safety Analysis Report, Drawing 729E471BB, Sheet 3, Functional Control Diagram Control Rod Drive Hydraulic System
ML21130A228
Person / Time
Site: Cooper 
Issue date: 04/21/2021
From:
Nebraska Public Power District (NPPD)
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21130A114 List: ... further results
References
NLS2021013
Download: ML21130A228 (1)


Text

1 A

B C

D E

F G

H J

ci

z 1

POWER AVAILABLE (ROD SELECT POWER SWITCH)

PERMISSIVE WHEN SWITCH IS ON RMS PERMISSIVE WHEN RMS CR HAS NOT MALFUNCTIONED SH 1, E-1 PERMISSIVE IF ROD TIMING CONTROL HAS NOT MALFUNCTIONED 2

SELECT WITHDRAW CONTROL IS PERMISSIVE G-7 PERMISSIVE WHEN SELECTED ROD IS ENABLED H-3 (ROD OUT NOTCH OVERRIDE SWITCH)

PERMISSIVE WHEN EMERGENCY ROD IN SWITCH IS ON RMS X

SH 1, B-7 3

SELECT INSERT CONTROL IS PERMISSIVE G-10 4

ROD WITHDRAW CONTROL IS PERMISSIVE 5

POWER AVAILABLE PERMISSIVE WHEN INSERT BUS IS NOT ENERGIZED SH 4, G-7 SH 4, D-2 CONTINUOUS WITHDRAW CONTROL IS NOT PERMISSIVE SH 4, F-4 ANNUNCIATING ROD WITHDRAW BLOCK CONTROL IS NOT PERMISSIVE (CHANNELS A & B)

SH 5, H-9, H-10 PERMISSIVE AFTER TIME DELAY OF 2 +.05 SEC

-0,0 TIMER TEST SWITCH PERMISSIVE WHEN TEST SWITCH IS ON RMS CR 6

E-5 SELECT WITH-DRAW CONTROL IS NOT PERMISSIVE G-7 SELECT INSERT CONTROL IS NOT PERMISSIVE G-10 ROD MOVEMENT CONTROL SWITCH PERMISSIVE WHEN ROD OUT SWITCH IS ON RMS CR C-11, D-8, D-11 SH 4, D-4 PERMISSIVE FOR TIME DELAY OF 1 +1 SEC

-0 ROD MOVEMENT CONTROL SWITCH PERMISSIVE WHEN ROD IN SWITCH IS ON RMS B-7 PERMISSIVE WHEN SELECT INSERT CONTROL IS NOT PERMISSIVE G-10 NON-ANNUNCIATIN ROD WITHDRAW BLOCK CONTROL IS PERMISSIVE 8

SELECT WITH-DRAW CONTROL IS PERMISSIVE G-7 9

(ROD OUT NOTCH OVERRIDE SWITCH)

PERMISSIVE WHEN EMERGENCY ROD IN SWITCH IS NOT ON RMS SH 1, 8-7 10 ROD MOVEMENT CONTROL SWITCH PERMISSIVE WHEN ROD IN SWITCH IS ON RMS CR B-7 SH 4, E-8 PERMISSIVE FOR TIME DELAY OF 1 +1 SEC

-0 ROD MOVEMENT CONTROL SWITCH PERMISSIVE WHEN ROD OUT NOTCH SWITCH IS ON RMS B-7 PERMISSIVE WHEN SELECT WITHDRAW CONTROL IS NOT PERMISSIVE RWM INSERT CONTROL JS PERMISSIVE G-7 1 1 SELECT INSERT CONTROL IS PERMISSIVE G-10 12 (CONTROL ROD &

SELECT PB) PERM.

WHEN CONTROL ROD SELECTED BY OPERATOR C

CONTROL ROD TIMER MALFUNCTION RPSCTF

~t---------1 rrL._ ___

~

SH 5, G-10 SH 7, G-11 RMS CHANNEL A REFUEL MODE X

ONE ROD CONTROL NOT PERMISSIVE SH 1, 8-3 NOTE 1, SH SH 5, D-3 CHANNEL B REFUEL MODE ONE ROD CONTROL NOT PERMISSIVE SH 5, D-6 SELECT WITHDRAW CONTROL IS NOT PERMISSIVE G-7 SELECT INSERT CONTROL IS NOT PERMISSIVE G-10 2

SELECT WITHDRAW CONTROL IS PERMISSIVE G-7 PERMISSIVE WHEN SELECTED ROD ENABLED H-3 SELECTED ROD ENABLED 3

C1604 SELECT INSERT CONTROL IS PERMISSIVE G-10 C-2, G-3 CHANNEL A REFUEL MODE ONE ROD CONTROL IS PERMISSIVE SH 5, D-3 SH 1, A-7, 8-3 SH 4, G-3, G-5, G-8 SH 5, C-3, C-6 SH 7, C-11 4

(TIMER TEST SWITCH)

PERMISSIVE WHEN RESET SWITCH IS NOT ON RMS CR CHANNEL B REFUEL MODE C-5 ONE ROD CONTROL NOT PERMISSIVE SH 5, D-6 5

PERMISSIVE FOR TIME DELAY OF 9.8 SEC TABLE 1, SH 1 SELECT WITH-DRAW CONTROL PERMISSIVE FOR TIME DELAY OF 6.5 SEC TABLE 1, SH 1 CONTINUOUS WITHDRAW CONTROL IS NOT PERMISSIVE SH 4, F-4 B-2, C-5, C-8, F-2, D-10, G-2 SH 1, A-8 CONTINUOUS WITHDRAW CONTROL IS PERMISSIVE SH 4, F-4 PERMISSIVE FOR TIME DELAY OF 9.0 SEC TABLE I, SH 1 SELECT INSERT CONTROL PERMISSIVE FOR TIME DELAY OF 5.0 SEC TABLE 1, SH 1 CONTINUOUS INSERT CONTROL IS NOT PERMISSIVE SH 4, F-8 B-3, D-5, D-7, F-3, C-11, G-2 SH 1, A-8 NOTES:

CONTINUOUS INSERT CONTROL IS PERMISSIVE SH 4, F-8

1. FOR GENERAL NOTES AND REFERENCE DOCUMENTS SEE SHEET 1.
    • FOR PREVIOUS REVISIONS, SEE SUPERSEDED CARDS.
    • N02 REVISED AND REDRAWN PER APA DCN C93-1816 DR JAC AGB 11-23-93 DFT CKD APP DATE NO.

REVISIONS DCN REVISIONS BY N.P.P.D.

6 8

INFORMATION ONLY

  • THIS DRAWING GENERATED BY NPPD SIGNIFICANT NUMBER GROUP COOPER 2

3 NUCLEAR 4

5 6

STATION FUNCTIONAL CONTROL DIAGRAM CONTROL ROD DRIVE HYDRAULIC SYSTEM 9

10 1 1 452005834 CADD DRAWING DO NOT REVISE MANUALLY DRAWN DATE DR 10-29-93 GENERAL CHECKED DATE N

JAC 11-9-93 CX)

ELECTRIC*

0 APPROVED DATE 0

AGB 11-23-93 0

~ u FILMED REVISION Ii:

729E47188 SH. 3 N02 ~