ML21130A195
| ML21130A195 | |
| Person / Time | |
|---|---|
| Site: | Cooper (DPR-046) |
| Issue date: | 04/21/2021 |
| From: | Nebraska Public Power District (NPPD) |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML21130A114 | List:
|
| References | |
| NLS2021013 | |
| Download: ML21130A195 (1) | |
Text
A B
C D
E F
G H
j 1
2 3
4 5
6
- ..___.J...._ ____ 1 ____
___j_ ____ s ____
___L_ ____
9 ____
_L_ ____
1 o ____
_j_ ____
11 ____
..L_ ____
1_2 ___ ---,7 176 144 146
{201Al HY-I HY-IS 162 107 Z37 3/4"I-IY-15 3/4,"-so i 2-2 (10-R I* t 1" 0
- 119A -3/.1 "
- 8. REFERENCE DRAWING 11506013 SH. I, 2 AN03 FOR INSTRUMENT RACK 25-52.
9, ALL VALVES ARE IN THE CONTROL ROD DRIVE (CRD)
SYSTEM UNLESS DESIGNATED OTHERWISE.
N 1.C, E-69-II
@Jy
~ t;----------::--::----C,.(}---i f----{=]----,-----,r--=~.l.:l*"'C~RD!!;*:.,!1~19!!!.:-::,'l:!4_" ____
.!,3/4:!'4:.,"!;l-l~Y_:-'J_l:::S:__ ________ ~
~ i
~4"-51
- 10. THE START UP POSITION ASSUMES CRO-F-A IN SERVICE AND CRD-F-B IN STANDBY.
11, DEVICES 3-134, 3-135,3-136 AND 3-137 ARE INTERNAL TO THE HCU MANIFOLD CRD-HCU-M (XX-XX).
CONTRACT E-69-11 FOR CONT.
SEE DWG TOCOLDREFENCE--.:.LE;:G.:,:s __ ~_;
FOR CO~TlNUATJONr SEE DWG.2026 SH.1, ZONE H-8 028, ZONE K 7.ill (158)
(159)
DWG, 2028 !ONE G-6 r"\\i l/2'!26<1ri S7'A4IHlf/
1 CRD-17CV (3-15)
~OAJ71!A"-1; COWT;fl/&:T
~-,..---,-,IJ'--'--=---=~ /
- ., & 9--4
£ -t,,, - II
.5-IBS f-lYP/!AU< IC FOR CONT. SEE
\\
L--1
~ (50MICRa41 LJRIVIPVNP/4 FOR CON1: SE!'
,,<tlT~ )
(.1-J,;i}
.!IJ~ r., =C\\l DWG.202B ZONE G-6
/ (14 *J 13RV}
ri HV*'l.
3 153 4
11-130 1-tM-IDS-4'~
CH-3 "'
COND SUPPLY
\\
1 ~
0'.;;
FOR CON'T SEE I-*-*- Cr,.!lS _
'°'
DWG 2049 SH 4 (A.',
ZONE E-9 CI/-J FOR CONT SfE
_'7
/'CJt--.3 DWG.2028 ZONE G-~,......_ __,
/
t-"-..:r.?:'.--1 4" -ll51 04 RVJ,' m J.' *,,,,,,,,1 FOR CONT.
z *w--, "I SEE OWG. fie4 202B
~~ ZONE G-7 l H "t-I I 181 183 185 12018)
L **
142 182 (223) 2"
- 11---i---*-*-
1/2."-10""y.
I 39 )
l------'f l40 FOR CONT. SE£
<( _
72
,,,,:~";, A~M A
t DWG. 2028 a: -
ZONE G* 7 \\
I-,l, SEE DET A I L I
z ti)
'Al
,....l60.... ---1'---,'~~-F-\\139~~~~,164~~165~3*~*-t~'.---'::._~8:'.j!w!....--I 7'-
1.141 161 INER
{3-13)
CRD-18CV OPEN HYDRAULIC DRIVE HY-I I
PUMP lB (3-16 l _.CH=-3-'-S~
I "CR0-109 1/2,_"1Kl2) 1-C.li! 0- I II- -
'], "I,/ -I HY-I ~-H'f-1!5 1'!CRD-IIO TO FLOOR ORAIM 221 219 zzo tllHI (202U
'ti,' (I031
[il)
~"(1051 87 336 2*~17 1.-~,)
y i'"" '54' FOR CONT. SEf SEE DETAI~
~ T3.l..::'.:!.)
OWG. 2028 ZONE F-7
'A' FROM "74 55 EIS 3-309t------
'I; I
m i ::
13 I
2-2
"' ',-:r
"" u I -
'SEE B \\ ~ 201,.2.
'5\\-1 I, ZONE C *4 345 346 343 344 39 rl><4:J---l
- i-....31-1 342 CRD-F-C.3 DP!
I I
~
_j r -
_J 4'B 2-2 2-2 (1I-R HY-2 FOR CONT. SEE DWG. 2028 ZONE F-7 1"
(187) l 11 Rv) a,;122 1* ~~
-~ [91 )
"78
- H~FI L j----==---. !lJ6) 16 I~
3
- ~
I LJ'zzs 229 11w*
1" (188) 132 f?
SEE DWG. 2027 SH.2
\\
ZONE F-2
_Jj r; s.::::J6f DWG. 2027 SH.1
_ __:J ~
!!2
~NE F-6
,_.!!!,~~3.;I:_.3 -
1 NOTE: LCAVE WELD5 OPEN TIL
-~
AFTER FLUSH/Hr;; AS /1,/DICATCD
/
-~,
=~rr L,.
-E-r<,9-4' Wt-I
~
_Pl:l;/
~
157
!132 )
.11.,.,~J E-<.9-1 OJ "'
- ' a ;:
- 12. DEVICE SHOWN THUS t (x xx) DENOTES INSTRUMENT LINE SNUBBER.
. ~o
- 13. CONFIGURATION IS
-_.,. !2 OR 1 AVCO VALVE
~ NC
- J I
EITHER 2 ASCO VALVES f,,
_'f:._4'-.L~/,:::1-1:,:Y-,,;-.:;' s~M L.-J Y:,"12661 CONTRACT E 69-4 CONTRACT E 69-11 U=
a, z,
.., 11 243 11/2*1/Y-Js ~1 1
-~~-~---
225 22 1/2"
,: 13'.l FOR NO. OF HCU CONNECTED TO EACH BRANCH, SEE E-69-11 CONTRACTORS FLOW DIAG. CP-001 SH 2 FOR CONT. SEE DWG. 2028 ZONE G*7 ZONE F-8 FROM EIS 3-309 ---------< TO 314' 73 VALVE TO COND. I STORAGE Tl<.
FOR CONT. SEE CING. 2049 SH;II T'
I
1 TO ~4 "74 VALVE rl4;>TAT:-,.:,J.,.C.'{\\'ii15i3=-rl),17(j3.;"f'.!,:,;,.t.:f'r.;-,..-.,.,,-~.J r-Tffl-1 I I' 9-19
'1 rln 54 n@j I'
9-*
- 1.
TO FC-301
~"
~
108 1/2,"J@
109
~
~" Ill I "115 246 244 240 1,z"113
'12"114
!63A)
!~s)
DETAIL 'A FROM I--', EIS 3-309 1---~ TO Fl 214 i ~*1~1
~
@---+--@
I I
I eo 1,--,~,;-*9eo
/2 119 1
f---f--1'-I VALVE 224 222 1/i'
!17 t,2"
- 118~
DETAIL 'B' J-Zf$'6 294
- s-21s-,11 C'lf2* IA-174 I -..,o:)
ii.
0 0
<.J.,_
L.:._...J9-1 3,,
9.5 1TD 83 1-',
l2S T0 3/4!"84 VALVE L __ ---~7 233 231 232 71 DETAIL 'C' L
'/2: II r27 173) 280 279.,.__J 281 282 t
(:,1 j~£D(T'!'P) 3/4"' DRAIN CRD-CV-28CV
~
CRD-V-300 CRD-V-301 CRD-CV-32CV
~
RD-V-320 CRD-V-321 CRD-RV-22RV CRD-PRV-33 CRD-V-312 CRD-CV-40CV CRD-V-332 IIN IS IN/IS NO (50UTt-1)
BI..OCIC ~00 (TO\\
,..wJTHDJ..AWAL f
SL.OPE'f1FT 111 CV35 CV33 (218)
- Ul CRD-V-328
- z L.
- J
.(**
SL_Of>fl:FT VOt..UMES 209)
(211)
QH'I"*!
(SEE NOTE 16)
CONT. ON B&R DWG.2028 ZONE F-5 1/2" INST. AIR CRD-~30CV CRD-V-317 CRD-V-316 CRD-~34CV CRD-V-325 CRD-V-324
, 1-'-F"ICILcsl------lll tr"'---==--'..:;c.--=.
CV32A IIN IS IN/IS R
OPEN TO ATMOSPHERE T
FROM OTHER HYDRAULIC CONTROL ROD UNITS FOR (208
,(206) fa*,.,
(202)
(217)
CV34 CV36 Ul CRD-V-329
!:2::::
L.:J z 2:;
CONT. ON B&R DWG.202B ZONE E-1 RD- -31 B CRD- -319 CRD-Qi=-35CV 116
'1
3 if ~" :~1 ~ ~
~~ ~~
I e~ )
L - ~
- t4" (Bl) a
- d....
<J j
~*IA*f.S
/f!HI-IS 1/-z" IA 15
,1 "
- -ZIA-IS FROM REACTOR PROTECTION SYS
!11<-1 CRO-CV-29C
~
CRD-V-303 CRD-V-302 CRO-CV-33C
~
CRD-V-323 CRD-V-322 CRD-RV-23RV CRD-PRV-34 CRD-V-313 CRD-CV-41CV CRD-V-333 IIN IS NO IN/IS FC CV328
~.-
B"HY-3 IIN IS IN/IS 276 I
275 277 I
278
- CRD-299 CAO-I 27CV
!' "-38 I 92 )
I 't I P/*15 3/4 * (BQj FOR-CONT. SEE ~WG. 2026-SH.1, ZONE H-3 1
"'::""".'fl ~"1,;'";T 3"4" (83) J ti)
IA-V-985
- !'i
~
l I ".5 )
/
1/2' IA-(246) l----!Xl---.
J IA-1596 J
L_ ____ --" IA-245 1,z' IA-171 S-/874' [m) r /1--~-ttt"' ~A *!7C C~A..'T~cT ! CO,VT'RACT ~
c *'--,-11 E-G '7-4
'-11:
I!:D IA-6)
-C~0-104-1" (TYP)
FOR NUMBER OF HCU CONNECTED DRAIN BRANCH SEE CONTRACTORS FLOW DIAGRAM DWG CNS-CRD-13 FOR NO. OF DRAIN BRANCHES REQ'D SEE CONTRACTORS FLOW DIAGRAM DWG CNS-CRD-13 2
3 N
N N
I I
I
~N~~~N
=~.---
4 N
I
~~
5 B
FOR CONT. SEf DWG. 2028 ZONE F-3 B, ZONE F~6 1-Cli'O-lo2-2" FOR NUMBER OF HCU CONNECTED TO EACH BRANCH SEE E-69-11 CONTRACTORS FLOW DIAGRAM CP-001 SH 2 A
B C
D 3/4, r*~
3/4'.'-57J I VI'-/)
NOTES' (cont.)
- 13.
INSTRUMENT, SAMPLE, TEST, DRAIN
- 14.
AND VERT LINES ARE NOT ALWAYS THE SAME CLASS AS THE MAIN LINE AND THESE BOUNDARIES ARE TOO NUMEROUS TO IDENTIFY IN THIS MANNER (SEE ISI PROGRAM BOUNDARY DESCRIPl'IONS FOR DETAILS!
THE REDUNDANT SEALS AND RESTRICTIVE FLOW AREAS THAT ARE INHERENT TO THE CRD'S PROVIDE THE REQUIRED REDUN-DANT REACTOR COOLANT PRESSURE BOUNDARY ISOLATION.
- 15.
VALVES 25CV &: 26CV ARE ESSENTIAL, CLASS IS.
(REFERENCE DC 89-285) AND THE CHECK VALVE ASSEMBLY IS RESTRAINED TO SEISMIC CLASS IS CRITERIA.
- 16.
SIGHT GLASS ASSEMBLY MOUNTED ON EACH INSTRUMENT VOLUME, AND ONLY CONNECTED DURING TESTING.
FOR NUMBER OF HCU CONNECTED TO EACH BRANCH SEE E-69-11 CONTRACTORS FLOW DIAGRAM CP-001 SH 2 t
1/4" 1/fr'HY. IS i-CRD-103-11'&
0 thil~ I.$
L-----~-------------------,---~'--'-'-~-=--,-,------~~=.:.=..--__;~ ______ ___.!..~!...!.:.~---_:_----~h--4--,--~---4-Cir.tt-]
COOi.iA./¥ W"f!Z /-iOJZ
~
~
~
'-9-4" 58 l,2" IA-I69
[1/(1 )
SC N2*26 11/2" IA-I68 I 12? )
,t"',OM RGAt:7cR Pt</ t:7T £cT/QN s y,;n,J1 IA-1601 3/4"JA-(244)
I N2-51 l (N2
- 13'ill~ \\
@1A"'. \\
1'12-27"'):
' IA-578 IA
'ST!
IA*
575 IA*
576
/-IA-/Of-1-N,~ Jl):5'-1/.& *1.
>12" Al*IS NZ-29 I l2~A) j "~")
N2*22 l
HOSES FOR
=r ACCUMULATOR S-165 1 HE Ao ER V-4LV£ ((YI_P._:) ~..,t.---
}-..,,..2
,;. CYt 1ND~.r:( VAtVE11"YP)-
- - RcllE~ VIILVE{r'r'P.)-.:.
NITROGEN CHARGING MANIFOLD SYS. 1 B
-~.. s__ l I Vlf-4-)
_:i,,
U + V -
SOUTH W + X -
NORTH FOR NO. OF HCU CONNECTED TO EACH BRANCH SEE E-69-11 CONTRACTORS FLOW DIAGRAM CP-001 SH 2
~
II\\
~
}..
I
.~,.~t.~
A4
- I~ ~ ~I u
V w
0 Q.,_
' ~~-------'
X NOTE:
ALL ITEMS MARKED THUS 0 ARE "AS-BUILT" INTEMS AND ARE NOT SHOWN ON PIPING DRAWINGS.
REVISIONS TO THIS DRAWING REQUIRES A REVISION TO THE CORRESPONDING ISOKEY.
SIGNIFICANT NUIIIBER GROUP 4
~
G DRAWN DATE CHEO<ED DATE AS BUILT 454003632 STATUS: Release STATUS DATE: 06/13/2019 DS APPROVED: NEWERNE VER: AF REV: 63 SIZE: F VERSIONS/REVISIONS BY NPPD BURNS & ROE
~
NO.
DESCRIPTION ORDER DFT DATE ENG 6030460 DJB 10 18 1 KKKUKE 6030460 PAM 10 21 1 KKKUKE APPROVED DATE N
0 Q
CONNECTIONS TO A.
s L_-----------------GIVEN SCRAM VOLUME
_j AD 61 DR-2013-0598 FROW VERSION AB AE 62 DR-2013-0598 FROW VERSION AC AF 63 DR-2018-0001 DJB 6 13 1 EWERN FLOW DIAGRAM CONTROL ROD DRIVE HYDRAULIC SYSTEM COOPER NUCLEAR STATION SEE ~q_ip05SEDED O
~u 1--_:c;=c__....1... _________ -< C HOR., SEE CONTRACTOR FLOW DIAGRAM CP-001 SH.2 FILMED
~
2039 1
2 3
4 5
6 7
8 9
10 1 1 12 A
B C
D E
F G
H j