ML21130A183
| ML21130A183 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 04/21/2021 |
| From: | Nebraska Public Power District (NPPD) |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML21130A114 | List:
|
| References | |
| NLS2021013 | |
| Download: ML21130A183 (1) | |
Text
A B
C 0 --
F H
J K
~1 ____
2__._l_~!:~_.... l_....._1 ___ ~3 _____...,_! _____
4 ____
__.l..__ __
___.l _ _,,1:.... 5..;__._: _ ___.l _____ 6 ______ __.._l ___ __._l_7 ____
__,_j ___
..._i1 __,~..._!_..._l--'e _____ _..__1 ____
9 __ ~
__,___1 ____
1;.._;o---____ !..__._l_... i 1!.___,.:_;1..,;.I ____
__.l __ ~
cE_*_r_**-L_@_E_lE_c~r*,...1_c_--11~ IF 25'2. &.
r-1--,.,,-,,,,...,==-=--.--==,,-.--,.==,,,,.,,=:e-:,::-,, oe=,--+-----------<,,,,, PROCE"- C. DI" r -R". *,
-*,. ~"'
l
(
\\
1 MOI MO 12-I \\
E \\__f V 87. I' 14
!,,AAAA '
13 0
7 REACT~
PRESSURE:..
VE5SE.L A
- cp
. -EL 111 I
~
2:
i i l 3
4
~
MO
'2.6 I
LBJ
'y I
I I I I
I 01~1-+-
~
GRAOE EL 41.t.'
~
~..
r© Jl ~
iO't'---)
It
~---(3
'." ~
11
~I ELQ __
__,c__.,,~2 IO B
6 CONDENSATE.
__,,__:STORAGE.~
TAl'lK 17 UHlESS OTMEltWIS( SPEC!Fl!.O USE TH£ ~OLLOWING -
.J.;;;
~\\J
,.\\lVI
""'-'£0 ~*cnc,s su*'*CEs h,,.,~r,.";!.:;;;:r-*~'T'""";,.~:*:.-:,;:iii'.":='i'~*=*-,*-mr*.~ \\ C,, I ~ ?_8 2-BC CORE SPRA-Y S YSTE.M
,/
~
~
~
to,rt,,... ~m -
,., "° l
Wl'ST MAO£ F'~ NUCLEAR BOILER. SYS.
--~------------*-
CONDITION l NORMAL SYSTEM TE$T LOCATION I
- 2.
3 4
5 6
8 9
\\0 FLOW-C:,PM N/f>.. 4TZD 14120 0
0 l\\Tc.C 0
0
- PRESS-PSIA l4.7 TEMP -
°F 95 95 95 95 95 95 NOTE 13
\\3
\\3
\\3 13 6P-FT_ *"25 *
._8.34-
'--------~-----'---------'-----'-----'----'----'---"--***-
C..ONDIT!ON II. TEST U51NG CCNDE.NSATE. -STORAGE Ti\\NK LOCATION l
- 2.
3 4
'5 6
7 B
9 10 FLQ\\N -c, PM N/A,oor C,000 0
o c;ooo PR'e'Sti-P51A 14.7 14.7 TE.MP-OF 90 90 90 NOTE Go, 14 l,14 l.14 L'IP-i='T.
.._ 4eo
- -3'2.0....
...,3,5___.
... ~P,84.7 FT.
.. I (SEE NOTE. e, J CONDITION fil P\\JMP OPERATING 00 BYPA$S (1$0LA.TION VALVE~ CLOSE.DJ LOCATION I I Z.
- i.
4 5
7 8
9 10 FLON -c, PM N/A 475 475 0
0 0
0 0
475 0
PRES!::,*PSiA 14.7 TEMP* °F 140 140 140 140 NOTE CONDITION IV CORE. ':!PRAY IN..J(C,\\N8 AT REACTOR PRE55 LOCATION I
- 2.
=,
4 5
<o 7
B 9
10 FLOW *GPM N/A 4720
- 47.:':0 %25 0 0
0 PRESS* PSI ti-29.6 11-0.1 "TEMP
- OF 208.7 208.7 NOTE 10 l I L:,P- ~T
..-6~5 -11
..-e.,14..
.- I '18 -
I
- 6P*5c..4FT (SEE NOTE BJ FOR PREVIOUS REVISIONS, SEE SUPERSEDED CARDS.
REVISIONS BY N.P.P.O.
NO.
REVISIONS OFT CKD APP DATE N06 EE 02-03.3 (DCN 02-0720)
RAC RHG KG 11-2-02 la 9
10 I l l t 1 238XIOOBB I
FC.F 2.39X358BB MPL 14-101 NOTES:
- 1.
ALL ELEVATIONS ARE WITH RESPECT TO PUMP & ELEVATION WHICH IS ASSUMED "O".
- 2.
ALLOWANCE FOR SYSTEM PIPE FRICTION, VALVE & FITTING LOSSES ETC. ARE REFLECTED BY THE PRESSURES REPORTED IN THIS TABULATION.
THIS ALLOWANCE IS BASED ON PRELIMINARY LAYOUTS
& THE DATA & METHODS PRESENTED IN CRANE TECHNICAL PAPER 410 ASSUMING CLEAN PIPE EXCEPT FOR CARBON STEEL PIPE.
FOR RUNS OF CARBON STEEL PIPE (NOT CARBON STEEL VALVES &
FITTINGS) A MARGIN OF 20% ABOVE THE CLEAN FRICTION LOSS IS INCLUDED.
PIPE FRICTION, VALVE & FITTING LOSSES ETC. MAY BE DISTRIBUTED THROUGHOUT SYSTEM AS REQUIRED BY FINAL SYSTEM LAYOUT CONSIDERATIONS AS LONG AS THE TOTAL DOES NOT EXCEED THAT INDICATED ON THIS DIAGRAM.
- 3.
A.E. WILL BE RESPONSIBLE TO INSURE THAT THE PIPING LOSSES ARE WITH IN THE LIMITS SPECIFIED ON THIS DRAWING AND SHALL REPORT DEVATION TO A.P.E.D.
- 4.
THE BY-PASS FLOW IS APPROXIMATE AND WILL BE SPECIFIED BY THE PUMP VENDOR.
- 5.
ONLY ONE CORE SPRAY LOOP IS SHOWN.
THE SECOND LOOP IS IDENTICAL.
EXCEPT FOR S.W. INTERTIE.
- 6.
IN CONDITION II THE NET POSITIVE SUCTION HEAD (NPSH)
AVAILABLE AT THE PUMP INLET (LOCATION 2) MUST BE GREATER THAN OR EQUAL TO 32 FT OR PUMP MANUFACTURE SPECIFIED NPSH.
- 7.
PARTS ARE NUMBERED AS PER CORE SPRAY P & ID MPL # 14.
- 8.
THIS L':.P DOES NOT INCLUDE ELEVATION LOSSES OR GE SUPPLIED EQUIPMENT L':.P.
- 9.
- 10.
IN CONDITION IV THE NET POSITIVE SUCTION PRESSURE (NPSH) IS EVALUATED IN NEDC 97-044A.
- 11. 95 GPM THERMAL SLEEVE LEAKAGE.
- 12. THIS DRAWING REFLECTS THE AS BUILT CONFIGUATION PER BURNS & ROE CORE SPRAY SYSTEM P & ID, DRAWING #2045, REV 17.
- 13. TECHNICAL SPECIFICATION SURVEILLANCE REQUIRES A MINIMUM FLOW OF 4720 GPM AT 113 PSID.
THIS ENSURES THAT THE ECCS ANALYSIS ASSUMED FLOW RATES ARE MET.
- 14.
CONDITION II TESTS ARE NOT PERFORMED AS PART OF SURVEILLANCE TEST! NG PROGRAM.
- 15.
CONDITION IV TEMPERATURE AND PRESSURE REFLECT DBA-LOCA CONDITIONS (NEDC 94-034C).
VALVE ~ITIONS VALVE NO.
C.OOOITION 5
7 e 12 2.<.
I C
0 C
C
?
Il C
C 0
0 C
m 0
0 C.
C C
N C
0 C
0 C
0 - FU.J... OPEN C
- FULL CL.OSE.D P-PARTl~lJ.. Y OPEN AS BUILT 454004929 ta SCAN/CADD DWG DO NOT REVISE MANUALLY CADD FlLE; C0046340 CENEIAl@ lllCTIIC REV N06 NEBO
~.. N ~
161 F282BC SH. 1 I P~L-.. I