ML21125A582

From kanterella
Jump to navigation Jump to search
0 to Updated Final Safety Analysis Report, Chapter 14, Table 14.4.2-1A, Equipment Required to Shutdown Reactor (Unit 1)
ML21125A582
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 04/19/2021
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21126A238 List: ... further results
References
AEP-NRC-2021-19
Download: ML21125A582 (137)


Text

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page:

1 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-33-IRV-310 East RHR Heat Exchanger HE-17E Outlet Flow Control Valve IRV-310 Limit Switch 120V/220 Control and Instrumentation Auxiliary 609 East RHR Heat Exchanger Room 5

1-33-IRV-311 RHR Heat Exchanger Bypass Flow Control Steam Leakoff Valve IRV-311 Limit Switch 120V/220 Control and Instrumentation Auxiliary 609 East RHR Heat Exchanger Room 5

1-HE-17E East RHR Heat Exchanger Residual Heat Removal Auxiliary 609 East RHR Heat Exchanger Room 5

1-ICM-311 East RHR to RC Loops #1 and #4 Cold Legs Motor Operated Containment Isolation Valve Residual Heat Removal Auxiliary 609 East RHR Heat Exchanger Room 5

1-IMO-312 East RHR Heat Exchanger HE-17E Outlet Mini-Flow Line Motor Operated Shutoff Valve Residual Heat Removal Auxiliary 609 East RHR Heat Exchanger Room 5

1-IMO-314 East RHR Heat Exchanger 1-HE-17E Discharge Crosstie Shutoff Valve Residual Heat Removal Auxiliary 609 East RHR Heat Exchanger Room 5

UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page:

2 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-IMO-330 East RHR to Upper Containment Spray Motor Operated Shutoff Valve Residual Heat Removal Auxiliary 609 East RHR Heat Exchanger Room 5

1-IMO-340 East RHR Heat Exchanger to Charging Pumps Suction Motor Operated Shutoff Valve Residual Heat Removal Auxiliary 609 East RHR Heat Exchanger Room 5

1-IRV-310 East RHR Heat Exchanger HE-17E Air Operated Outlet Flow Control Steam Leakoff Valve Residual Heat Removal Auxiliary 609 East RHR Heat Exchanger Room 5

1-IRV-311 RHR Heat Exchangers Air Operated Bypass Flow Control Valve Residual Heat Removal Auxiliary 609 East RHR Heat Exchanger Room 5

1-RH-117 RHR Heat Exchanger Bypass Manual Isolation Valve Residual Heat Removal Auxiliary 609 East RHR Heat Exchanger Room 5

1-SV-104E East RHR Heat Exchanger HE-17E Outlet Safety Valve Residual Heat Removal Auxiliary 609 East RHR Heat Exchanger Room 5

UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page:

3 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-33-IRV-320 West RHR Heat Exchanger HE-17w Outlet Flow Control Valve IRV-320 Limit Switch 120V/220 Control and Instrumentation Auxiliary 609 West RHR Heat Exchanger Room 6

1-HE-17W West RHR Heat Exchanger Residual Heat Removal Auxiliary 609 West RHR Heat Exchanger Room 6

1-ICM-321 West RHR to Reactor Coolant Loops #2 and #3 Cold Legs Motor Operated Containment Isolation Valve Residual Heat Removal Auxiliary 609 West RHR Heat Exchanger Room 6

1-IMO-322 West RHR Heat Exchanger HE-17W Outlet Mini-Flow Line Motor Operated Shutoff Valve Residual Heat Removal Auxiliary 609 West RHR Heat Exchanger Room 6

1-IMO-324 West RHR Heat Exchanger 1-HE-17W Discharge Crosstie Shutoff Valve Residual Heat Removal Auxiliary 609 West RHR Heat Exchanger Room 6

1-IMO-331 West RHR to Upper Containment Spray Motor Operated Shutoff Valve Residual Heat Removal Auxiliary 609 West RHR Heat Exchanger Room 6

UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page:

4 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-IMO-350 West RHR Heat Exchanger Outlet to Safety Injection Pump Suction Motor Operated Shutoff Valve Residual Heat Removal Auxiliary 609 West RHR Heat Exchanger Room 6

1-IRV-320 West RHR Heat Exchanger HE-17W Air Operated Outlet Flow Control Steam Leakoff Valve Residual Heat Removal Auxiliary 609 West RHR Heat Exchanger Room 6

1-SV-104W West RHR Heat Exchanger HE-17W Outlet Safety Valve Residual Heat Removal Auxiliary 609 West RHR Heat Exchanger Room 6

1-HV-AES-1 Auxiliary Building Ventilation Engineered Safety Feature Exhaust Fan Auxiliary Building Ventilation Auxiliary 633 Normal Blowdown Flashtank Room 8

1-HV-AES-1 (FLT)

Auxiliary Building Ventilation Engineered Safety Feature Exhaust Air Filter Auxiliary Building Ventilation Auxiliary 633 Normal Blowdown Flashtank Room 8

1-HV-AES-1-D1 Auxiliary Building Ventilation Engineered Safety Feature Exhaust HV-AES-1 Charcoal Filter Bypass Damper #1 Auxiliary Building Ventilation Auxiliary 633 Normal Blowdown Flashtank Room 8

UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page:

5 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-HV-AES-1-D2 Auxiliary Building Ventilation Engineered Safety Feature Exhaust HV-AES-1 Charcoal Filter Bypass Damper #2 Auxiliary Building Ventilation Auxiliary 633 Normal Blowdown Flashtank Room 8

1-HV-AES-1-D3 Auxiliary Building Ventilation Engineered Safety Feature Exhaust HV-AES-1 Charcoal Filter Face Damper Auxiliary Building Ventilation Auxiliary 633 Normal Blowdown Flashtank Room 8

1-HV-AES-2 Auxiliary Building Ventilation Engineered Safety Feature Exhaust Fan Auxiliary Building Ventilation Auxiliary 633 Normal Blowdown Flashtank Room 8

1-HV-AES-2 (FLT)

Auxiliary Building Ventilation Engineered Safety Feature Exhaust Air Filter Auxiliary Building Ventilation Auxiliary 633 Normal Blowdown Flashtank Room 8

1-HV-AES-2-D1 Auxiliary Building Ventilation Engineered Safety Feature Exhaust HV-AES-2 Charcoal Filter Bypass Damper #1 Auxiliary Building Ventilation Auxiliary 633 Normal Blowdown Flashtank Room 8

1-HV-AES-2-D2 Auxiliary Building Ventilation Engineered Safety Feature Exhaust HV-AES-2 Charcoal Filter Bypass Damper #2 Auxiliary Building Ventilation Auxiliary 633 Normal Blowdown Flashtank Room 8

UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page:

6 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-HV-AES-2-D3 Auxiliary Building Ventilation Engineered Safety Feature Exhaust HV-AES-2 Charcoal Filter Face Damper Auxiliary Building Ventilation Auxiliary 633 Normal Blowdown Flashtank Room 8

1-XSO-560 Auxiliary Building Ventilation Engineered Safety Feature Exhaust Damper AES-2-D3 Control Solenoid Control Air Auxiliary 633 Normal Blowdown Flashtank Room 8

1-XSO-561 Auxiliary Building Ventilation Engineered Safety Feature Exhaust Damper AES-1-D3 Control Solenoid Control Air Auxiliary 633 Normal Blowdown Flashtank Room 8

1-XSO-562 Auxiliary Building Ventilation Engineered Safety Feature Exhaust Damper AES-1-D3 Control Solenoid Control Air Auxiliary 633 Normal Blowdown Flashtank Room 8

1-XSO-563 Auxiliary Building Ventilation Engineered Safety Feature Exhaust Damper AES-1-D3 Control Solenoid Control Air Auxiliary 633 Normal Blowdown Flashtank Room 8

1-XSO-564 Auxiliary Building Ventilation Engineered Safety Feature Exhaust Damper AES-2-D3 Control Solenoid Control Air Auxiliary 633 Normal Blowdown Flashtank Room 8

UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page:

7 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-XSO-565 Auxiliary Building Ventilation Engineered Safety Feature Exhaust Damper AES-2-D3 Control Solenoid Control Air Auxiliary 633 Normal Blowdown Flashtank Room 8

1-XSO-590 Auxiliary Building Ventilation Engineered Safety Feature Exhaust Dampers AES-2-D1 and 2-D2 Control Solenoid Control Air Auxiliary 633 Normal Blowdown Flashtank Room 8

1-XSO-591 Auxiliary Building Ventilation Engineered Safety Feature Exhaust Dampers AES-1-D1 and 1-D2 Control Solenoid Control Air Auxiliary 633 Normal Blowdown Flashtank Room 8

1-XSO-592 Auxiliary Building Ventilation Engineered Safety Feature Exhaust Dampers AES-1-D1 and 1-D2 Control Solenoid Control Air Auxiliary 633 Normal Blowdown Flashtank Room 8

1-XSO-593 AuxiliaryBuilding Ventilation Engineered Safety Feature Exhaust Dampers AES-1-D1 and 1-D2 Control Solenoid Control Air Auxiliary 633 Normal Blowdown Flashtank Room 8

UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page:

8 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-XSO-594 Auxiliary Building Ventilation Engineered Safety Feature Exhaust Dampers AES-2-D1 and 2-D2 Control Solenoid Control Air Auxiliary 633 Normal Blowdown Flashtank Room 8

1-XSO-595 Auxiliary Building Ventilation Engineered Safety Feature Exhaust Dampers AES-2-D1 and 2-D2 Control Solenoid Control Air Auxiliary 633 Normal Blowdown Flashtank Room 8

1-33-MRV-221 Steam Generator #2 Stop Valve MRV-220 Steam Cylinder Train A Dump Valve MRV-221 Limit Switch 250VDC Control and Instrumentation Auxiliary 633 West Main Steam Stop Enclosure 9

1-33-MRV-222 Steam Generator #2 Stop Valve MRV-220 Steam Cylinder Train B Dump Valve MRV-222 Limit Switch 250VDC Control and Instrumentation Auxiliary 633 West Main Steam Stop Enclosure 9

1-33-MRV-223 Steam Generator #2 PORV MRV-223 Limit Switch 250VDC Control and Instrumentation Auxiliary 633 West Main Steam Stop Enclosure 9

UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page:

9 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-33-MRV-231 Steam Generator #3 Stop Valve MRV-230 Steam Cylinder Train A Dump Valve MRV-231 Limit Switch 250VDC Control and Instrumentation Auxiliary 633 West Main Steam Stop Enclosure 9

1-33-MRV-232 Steam Generator #3 Stop Valve MRV-230 Steam Cylinder Train B Dump Valve MRV-232 Limit Switch 250VDC Control and Instrumentation Auxiliary 633 West Main Steam Stop Enclosure 9

1-33-MRV-233 Steam Generator #3 PORV MRV-233 Limit Switch 250VDC Control and Instrumentation Auxiliary 633 West Main Steam Stop Enclosure 9

1-33-SG2H Steam Generator #2 Stop Valve MRV-220 Limit Switch 120V/220 Control and Instrumentation Auxiliary 633 West Main Steam Stop Enclosure 9

1-33-SG3H Steam Generator #3 Stop Valve MRV-230 Limit Switch 120V/220 Control and Instrumentation Auxiliary 633 West Main Steam Stop Enclosure 9

1-FFI-220 Auxiliary Feedwater to Steam Generator OME-3-2 Flow Indicator Transmitter Auxiliary Feedwater Auxiliary 621 West Main Steam Stop Enclosure 9

UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page: 10 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-FFI-230 Auxiliary Feedwater to Steam Generator OME-3-3 Flow Indicator Transmitter Auxiliary Feedwater Auxiliary 621 West Main Steam Stop Enclosure 9

1-FW-118-2 Feedwater to Steam Generator #2 Containment Isolation Check Valve Feedwater Auxiliary 621 West Main Steam Stop Enclosure 9

1-FW-118-3 Feedwater to Steam Generator #3 Containment Isolation Check Valve Feedwater Auxiliary 621 West Main Steam Stop Enclosure 9

1-MCM-221 Main Steam Lead #2 to Auxiliary Feed Pump Turbine Motor Operated Shutoff Valve Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-MCM-231 Main Steam Lead #3 to Auxiliary Feed Pump Turbine Motor Operated Shutoff Valve Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-MMO-220 Steam Stop Valve MRV-220 Steam Cylinder Dump Valve 4" Motor Operated Selector Valve Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page: 11 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-MMO-230 Steam Stop Valve MRV-230 Steam Cylinder Dump Valve 4" Motor Operated Selector Valve Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-MPP-220 Steam Generator OME-3-2 Channel I Steam Pressure Transmitter Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-MPP-221 Steam Generator OME-3-2 Channel II Steam Pressure Transmitter Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-MPP-222 Steam Generator OME-3-2 Channel III Reactor Protection Input Steam Pressure Transmitter Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-MPP-230 Steam Generator OME-3-3 Channel I Steam Pressure Transmitter Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-MPP-231 Steam Generator OME-3-3 Channel II Steam Pressure Transmitter Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page: 12 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-MPP-232 Steam Generator OME-3-3 Channel III Reactor Protection Input Steam Pressure Transmitter Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-MRV-220 Steam Generator OME-3-2 Stop Valve Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-MRV-221 Steam Generator #2 Stop Valve MRV-220 Steam Cylinder Train 'A' Dump Valve Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-MRV-222 Steam Generator #2 Stop Valve MRV-220 Steam Cylinder Train 'B' Dump Valve Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-MRV-223 Steam Generator OME-3-2 Power Operated Relief Valve Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-MRV-230 Steam Generator OME-3-3 Stop Valve Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page: 13 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-MRV-231 Steam Generator #3 Stop Valve MRV-230 Steam Cylinder Train 'A' Dump Valve Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-MRV-232 Steam Generator #3 Stop Valve MRV-230 Steam Cylinder Train 'B' Dump Valve Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-MRV-233 Steam Generator OME-3-3 Power Operated Relief Valve Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-SV-1A-2 Steam Generator OME-3-2 Safety Valve 1A Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-SV-1A-3 Steam Generator OME-3-3 Safety Valve 1A Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-SV-1B-2 Steam Generator OME-3-2 Safety Valve 1B Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page: 14 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-SV-1B-3 Steam Generator OME-3-3 Safety Valve 1B Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-SV-2A-2 Steam Generator OME-3-2 Safety Valve 2A Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-SV-2A-3 Steam Generator OME-3-3 Safety Valve 2A Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-SV-2B-2 Steam Generator OME-3-2 Safety Valve 2B Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-SV-2B-3 Steam Generator OME-3-3 Safety Valve 2B Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-SV-3-2 Steam Generator OME-3-2 Safety Valve #3 Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page: 15 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-SV-3-3 Steam Generator OME-3-3 Safety Valve #3 Main Steam Auxiliary 633 West Main Steam Stop Enclosure 9

1-33-MRV-211 Steam Generator #1 Stop Valve MRV-210 Steam Cylinder Train A Dump Valve MRV-211 Limit Switch 250VDC Control and Instrumentation Auxiliary 633 East Main Steam Stop Enclosure 10 1-33-MRV-212 Steam Generator #1 Stop Valve MRV-210 Steam Cylinder Train B Dump Valve MRV-212 Limit Switch 250VDC Control and Instrumentation Auxiliary 633 East Main Steam Stop Enclosure 10 1-33-MRV-213 Steam Generator #1 PORV MRV-213 Limit Switch 250VDC Control and Instrumentation Auxiliary 633 East Main Steam Stop Enclosure 10 1-33-MRV-241 Steam Generator #4 Stop Valve MRV-240 Steam Cylinder Train A Dump Valve MRV-241 Limit Switch 250VDC Control and Instrumentation Auxiliary 633 East Main Steam Stop Enclosure 10 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page: 16 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-33-MRV-242 Steam Generator #4 Stop Valve MRV-240 Steam Cylinder Train B Dump Valve MRV-242 Limit Switch 250VDC Control and Instrumentation Auxiliary 633 East Main Steam Stop Enclosure 10 1-33-MRV-243 Steam Generator #4 PORV MRV-243 Limit Switch 250VDC Control and Instrumentation Auxiliary 633 East Main Steam Stop Enclosure 10 1-33-SG1H Steam Generator #1 Stop Valve MRV-210 Limit Switch 120V/220 Control and Instrumentation Auxiliary 633 East Main Steam Stop Enclosure 10 1-33-SG4H Steam Generator #4 Stop Valve MRV-240 Limit Switch 120V/220 Control and Instrumentation Auxiliary 633 East Main Steam Stop Enclosure 10 1-FFC-210 Feedwater to Steam Generator #1 Channel I Flow Control Transmitter Feedwater Auxiliary 621 East Main Steam Stop Enclosure 10 1-FFC-211 Feedwater to Steam Generator #1 Channel Ii Flow Control Transmitter Feedwater Auxiliary 621 East Main Steam Stop Enclosure 10 1-FFI-210 Auxiliary Feedwater to Steam Generator OME-3-1 Flow Indicator Transmitter Auxiliary Feedwater Auxiliary 621 East Main Steam Stop Enclosure 10 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page: 17 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-FFI-240 Auxiliary Feedwater to Steam Generator OME-3-4 Flow Indicator Transmitter Auxiliary Feedwater Auxiliary 621 East Main Steam Stop Enclosure 10 1-FMO-212 West Motor Driven Auxiliary Feedwater Pump Pp-3w Supply to Steam Generator OME-3-1 Motor Operated Control Valve Auxiliary Feedwater Auxiliary 612 East Main Steam Stop Enclosure 10 1-FW-118-1 Feedwater to Steam Generator #1 Containment Isolation Check Valve Feedwater Auxiliary 621 East Main Steam Stop Enclosure 10 1-FW-118-4 Feedwater to Steam Generator #4 Containment Isolation Check Valve Feedwater Auxiliary 621 East Main Steam Stop Enclosure 10 1-MMO-210 Steam Stop Valve MRV-210 Steam Cylinder Dump Valve 4" Motor Operated Selector Valve Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-MMO-240 Steam Stop Valve MRV-240 Steam Cylinder Dump Valve 4" Motor Operated Selector Valve Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-MPP-210 Steam Generator Ome-3-1 Channel I Steam Pressure Transmitter Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-MPP-211 Steam Generator OME-3-1 Channel II Steam Pressure Transmitter Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page: 18 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-MPP-212 Steam Generator OME-3-1 Channel IV Reactor Protection Input Steam Pressure Transmitter Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-MPP-240 Steam Generator OME-3-4 Channel I Steam Pressure Transmitter Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-MPP-241 Steam Generator OME-3-4 Channel II Steam Pressure Transmitter Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-MPP-242 Steam Generator OME-3-4 Channel IV Reactor Protection Input Steam Pressure Transmitter Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-MRV-210 Steam Generator OME-3-1 Stop Valve Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-MRV-211 Steam Generator #1 Stop Valve MRV-210 Steam Cylinder Train 'A' Dump Valve Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-MRV-212 Steam Generator #1 Stop Valve MRV-210 Steam Cylinder Train 'B' Dump Valve Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page: 19 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-MRV-213 Steam Generator OME-3-1 Power Operated Relief Valve Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-MRV-240 Steam Generator OME-3-4 Stop Valve Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-MRV-241 Steam Generator #4 Stop Valve MRV-240 Steam Cylinder Train 'A' Dump Valve Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-MRV-242 Steam Generator #4 Stop Valve MRV-240 Steam Cylinder Train 'B' Dump Valve Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-MRV-243 Steam Generator OME-3-4 Power Operated Relief Valve Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-SV-1A-1 Steam Generator OME-3-1 Safety Valve 1A Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-SV-1A-4 Steam Generator OME-3-4 Safety Valve 1A Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-SV-1B-1 Steam Generator OME-3-1 Safety Valve 1B Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page: 20 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-SV-1B-4 Steam Generator OME-3-4 Safety Valve 1B Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-SV-2A-1 Steam Generator OME-3-1 Safety Valve 2A Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-SV-2A-4 Steam Generator OME-3-4 Safety Valve 2A Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-SV-2B-1 Steam Generator OME-3-1 Safety Valve 2B Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-SV-2B-4 Steam Generator OME-3-4 Safety Valve 2B Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-SV-3-1 Steam Generator OME-3-1 Safety Valve #3 Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-SV-3-4 Steam Generator OME-3-4 Safety Valve #3 Main Steam Auxiliary 633 East Main Steam Stop Enclosure 10 1-XSO-221 Steam Generator #2 Stop Valve MRV-220 Steam Cylinder Train 'A' Dump Valve MRV-221 Control Solenoid Control Air Auxiliary 612 West Non-Essential Service Water Valve Gallery 11 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page: 21 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-XSO-222 Steam Generator #2 Stop Valve MRV-220 Steam Cylinder Train 'B' Dump Valve MRV-222 Control Solenoid Control Air Auxiliary 633 West Non-Essential Service Water Valve Gallery 11 1-XSO-231 Steam Generator #3 Stop Valve MRV-230 Steam Cylinder Train 'A' Dump Valve MRV-231 Control Solenoid Control Air Auxiliary 612 West Non-Essential Service Water Valve Gallery 11 1-XSO-232 Steam Generator #3 Stop Valve MRV-230 Steam Cylinder Train 'B' Dump Valve MRV-232 Control Solenoid Control Air Auxiliary 612 West Non-Essential Service Water Valve Gallery 11 1-EPT-223 Steam Generator OME 3-2 PORV MRV-223 Control Air Electro-Pneumatic Transducer Control Air Auxiliary 612 612 Airlock 12 1-EPT-233 Steam Generator OME 3-3 PORV MRV-233 Control Air Electro-Pneumatic Transducer Control Air Auxiliary 612 612 Airlock 12 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page: 22 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-EPT-213 Steam Generator OME 3-1 PORV MRV-213 Control Air Electro-Pneumatic Transducer Control Air Auxiliary 612 East Feedwater Regulating Valve Area 13 1-EPT-243 Steam Generator OME 3-4 PORV MRV-243 Control Air Electro-Pneumatic Transducer Control Air Auxiliary 612 East Feedwater Regulating Valve Area 13 1-FFC-240 Feedwater to Steam Generator #4 Channel I Flow Control Transmitter Feedwater Auxiliary 612 East Feedwater Regulating Valve Area 13 1-FFC-241 Feedwater to Steam Generator #4 Channel II Flow Control Transmitter Feedwater Auxiliary 612 East Feedwater Regulating Valve Area 13 1-FRV-210 Steam Generator OME-3-1 Feedwater Regulating Valve Feedwater Auxiliary 612 East Feedwater Regulating Valve Area 13 1-FRV-240 Steam Generator OME-3-4 Feedwater Regulating Valve Feedwater Auxiliary 612 East Feedwater Regulating Valve Area 13 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 1 of 6 Page: 23 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-XSO-291-1(2)

Steam Generator #1 Feedwater Regulating Valve FRV-210 Train 'A' Control Solenoids Control Air Auxiliary 612 East Feedwater Regulating Valve Area 13 1-XSO-292-1(2)

Steam Generator #1 Feedwater Regulating Valve FRV-210 Train 'B' Control Solenoids Control Air Auxiliary 612 East Feedwater Regulating Valve Area 13 1-XSO-297-1(2)

Steam Generator #4 Feedwater Regulating Valve FRV-240 Train 'A' Control Solenoids Control Air Auxiliary 612 East Feedwater Regulating Valve Area 13 1-XSO-298-1(2)

Steam Generator #4 Feedwater Regulating Valve FRV-240 Train 'B' Control Solenoids Control Air Auxiliary 612 East Feedwater Regulating Valve Area 13 1-ICM-250 Boron Injection Tank Train 'A' Outlet Motor Operated Containment Isolation Valve Boron Injection Auxiliary 612 Bit Outlet Valve Room 15 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page:

1 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-ICM-251 Boron Injection Tank Train 'B' Outlet Motor Operated Containment Isolation Valve Boron Injection Auxiliary 612 Bit Outlet Valve Room 15 1-IMO-255 Boron Injection Tank Train 'A' Inlet Motor Operated Shutoff Valve Boron Injection Auxiliary 612 Bit Room 16 1-IMO-256 Boron Injection Tank Train 'B' Inlet Motor Operated Shutoff Valve Boron Injection Auxiliary 612 Bit Room 16 1-SI-210 Boron Injection to Charging Pump Crosstie Check Valve Boron Injection Auxiliary 612 Bit Room 16 1-SV-97 Boron Injection Tank TK-11 Outlet Safety Valve Boron Injection Auxiliary 612 Bit Room 16 1-TK-11 Boron Injection Tank Boron Injection Auxiliary 612 Bit Room 16 1-HE-11 Reactor Coolant Pump Seal Water Heat Exchanger CVCS (Charging)

Auxiliary 609 Seal Water Heat Exchanger Room 18 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page:

2 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-SV-54 Reactor Coolant Pump Seal Water Heat Exchanger HE-11 Safety Valve CVCS (Letdown)

Auxiliary 609 Seal Water Heat Exchanger Room 18 1-QMO-451 Reactor Coolant Letdown Volume Control Tank TK-10 to CVCS Charging Pumps Train 'A' Shutoff Motor Operated Valve CVCS (Letdown)

Auxiliary 609 Volume Control Tank East Hallway 19 1-QMO-452 Reactor Coolant Letdown Volume Control Tank TK-10 to CVCS Charging Pumps Train 'B' Shutoff Motor Operated Valve CVCS (Letdown)

Auxiliary 609 Volume Control Tank East Hallway 19 1-TK-32 Condensate Storage Tank Auxiliary Feedwater (CST Supply)

Grounds 609 Condensate Storage Tank Area 20 1-TK-33 Refueling Water Storage Tank RWST Supply Grounds 609 RWST Area 21 1-VTS-340 AB Emergency Diesel Generator Room Ventilation Supply Fan HV-DGS-1 Outside Air Thermostat Diesel Room Ventilation Grounds 609 RWST Area 21 1-NRI-21-AMP Nuclear Instrumentation Wide Range Radiation Amplifier Cabinet Nuclear Instrumentation Auxiliary 596 Reactor Cable

Tunnel, Quadrant #1 25 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page:

3 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-NRI-23-AMP Nuclear Instrumentation Source Range Radiation Detector NRI-23 Amplifier Cabinet Nuclear Instrumentation Auxiliary 596 Reactor Cable

Tunnel, Quadrant #1 25 1-NRI-23-ISOL Nuclear Instrumentation Source Range Signal Isolator Cabinet Nuclear Instrumentation Auxiliary 596 Reactor Cable
Tunnel, Quadrant #1 25 1-HV-DGS-DAB AB Emergency Diesel Generator Room Ventilation Supply Fan HV-DGS-1 Outside Air Shutoff Damper Diesel Room Ventilation Auxiliary 596 Reactor Cable
Tunnel, Quadrant #3 26 1-VTS-345 CD Emergency Diesel Generator Room Ventilation Supply Fan HV-DGS-2 Outside Air Thermostat Diesel Room Ventilation Auxiliary 596 Reactor Cable
Tunnel, Quadrant #3 26 1-33-QCR-300 Reactor Coolant Letdown Train B Containment Isolation Valve QCR-300 Limit Switch 250VDC Control and Instrumentation Auxiliary 591 Vestibule 28 1-ICM-305 Recirculation Sump to East RHR/CTS Pumps Suction Motor Operated Containment Isolation Valve Residual Heat Removal Auxiliary 591 Vestibule 28 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page:

4 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-ICM-306 Recirculation Sump to West RHR/CTS Pumps Suction Motor Operated Containment Isolation Valve Residual Heat Removal Auxiliary 591 Vestibule 28 1-IFI-335 Residual Heat Removal to Reactor Coolant Loops #2 and #3 Cold Legs Flow Indicator Transmitter Residual Heat Removal Auxiliary 591 Vestibule 28 1-IMO-390 Refueling Water Storage Tank TK-33 to Residual Heat Removal Pumps Suction Motor Operated Shutoff Valve Residual Heat Removal Auxiliary 591 Vestibule 28 1-ITR-335 Residual Heat Removal to Reactor Coolant Loops #2 & #3 Cold Legs Temperature Recorder Thermal Sensor Residual Heat Removal Auxiliary 591 Vestibule 28 1-QCM-350 Reactor Coolant Pump Seal Water Return Train 'B' Containment Isolation Motor Operated Valve CVCS (Charging)

Auxiliary 591 Vestibule 28 1-QCR-300 Reactor Coolant Letdown Train 'B' Containment Isolation Valve CVCS (Letdown)

Auxiliary 591 Vestibule 28 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page:

5 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-XSO-300 Reactor Coolant Letdown Train 'B' Containment Isolation Valve QCR-300 Control Solenoid Control Air Auxiliary 591 Vestibule 28 1-33-DCR-310 Steam Generator #1 Blowdown Containment Isolation Valve DCR-310 Limit Switch 250VDC Control and Instrumentation Auxiliary 591 Startup Blowdown Flashtank Room 29 1-33-DCR-320 Steam Generator #2 Blowdown Containment Isolation Valve DCR-320 Limit Switch 250VDC Control and Instrumentation Auxiliary 591 Startup Blowdown Flashtank Room 29 1-33-DCR-330 Steam Generator #3 Blowdown Containment Isolation Valve DCR-330 Limit Switch 250VDC Control and Instrumentation Auxiliary 591 Startup Blowdown Flashtank Room 29 1-33-DCR-340 Steam Generator #4 Blowdown Containment Isolation Valve DCR-340 Limit Switch 250VDC Control and Instrumentation Auxiliary 591 Startup Blowdown Flashtank Room 29 1-DCR-310 Steam Generator OME-3-1 Blowdown Containment Isolation Valve Main Steam (Blowdown)

Auxiliary 591 Startup Blowdown Flashtank Room 29 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page:

6 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-DCR-320 Steam Generator OME-3-2 Blowdown Containment Isolation Valve Main Steam (Blowdown)

Auxiliary 591 Startup Blowdown Flashtank Room 29 1-DCR-330 Steam Generator OME-3-3 Blowdown Containment Isolation Valve Main Steam (Blowdown)

Auxiliary 591 Startup Blowdown Flashtank Room 29 1-DCR-340 Steam Generator OME-3-4 Blowdown Containment Isolation Valve Main Steam (Blowdown)

Auxiliary 591 Startup Blowdown Flashtank Room 29 1-DRV-311 Steam Generator OME-3-1 Blowdown Flow Control Valve Main Steam (Blowdown)

Auxiliary 591 Startup Blowdown Flashtank Room 29 1-DRV-312 Steam Generator OME-3-1 Blowdown Flow Control Valve Main Steam (Blowdown)

Auxiliary 591 Startup Blowdown Flashtank Room 29 1-DRV-321 Steam Generator OME-3-2 Blowdown Flow Control Valve Main Steam (Blowdown)

Auxiliary 591 Startup Blowdown Flashtank Room 29 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page:

7 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-DRV-322 Steam Generator OME-3-2 Blowdown Flow Control Valve Main Steam (Blowdown)

Auxiliary 591 Startup Blowdown Flashtank Room 29 1-DRV-331 Steam Generator OME-3-3 Blowdown Flow Control Valve Main Steam (Blowdown)

Auxiliary 591 Startup Blowdown Flashtank Room 29 1-DRV-332 Steam Generator OME-3-3 Blowdown Flow Control Valve Main Steam (Blowdown)

Auxiliary 591 Startup Blowdown Flashtank Room 29 1-DRV-341 Steam Generator OME-3-4 Blowdown Flow Control Valve Main Steam (Blowdown)

Auxiliary 591 Startup Blowdown Flashtank Room 29 1-DRV-342 Steam Generator OME-3-4 Blowdown Flow Control Valve Main Steam (Blowdown)

Auxiliary 591 Startup Blowdown Flashtank Room 29 1-FMO-221 Turbine Driven Auxiliary Feed Pump PP-4 Discharge to Steam Generator OME-3-2 Motor Operated Control Valve Auxiliary Feedwater Auxiliary 591 Startup Blowdown Flashtank Room 29 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page:

8 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-FMO-222 East Motor Driven Auxiliary Feedwater Pump PP-3E Supply to Steam Generator OME-3-2 Motor Operated Control Valve Auxiliary Feedwater Auxiliary 591 Startup Blowdown Flashtank Room 29 1-FMO-231 Turbine Driven Auxiliary Feed Pump PP-4 Supply to Steam Generator OME-3-3 Motor Operated Control Valve Auxiliary Feedwater Auxiliary 591 Startup Blowdown Flashtank Room 29 1-FMO-232 East Motor Driven Auxiliary Feedwater Pump PP-3E Supply to Steam Generator OME-3-3 Motor Operated Control Valve Auxiliary Feedwater Auxiliary 591 Startup Blowdown Flashtank Room 29 1-XSO-311 Steam Generator OME-3-1 Blowdown Containment Isolation Valve DCR-310 Control Solenoid Control Air Auxiliary 591 Startup Blowdown Flashtank Room 29 1-XSO-321 Steam Generator OME-3-2 Blowdown Containment Isolation Valve DCR-320 Control Solenoid Control Air Auxiliary 591 Startup Blowdown Flashtank Room 29 1-XSO-331 Steam Generator OME-3-3 Blowdown Containment Isolation Valve DCR-330 Control Solenoid Control Air Auxiliary 591 Startup Blowdown Flashtank Room 29 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page:

9 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-XSO-341 Steam Generator OME-3-4 Blowdown Containment Isolation Valve DCR-340 Control Solenoid Control Air Auxiliary 591 Startup Blowdown Flashtank Room 29 1-SSV-A1 250VDC Train 'A' Nuclear Sampling Feeder Panel #1 250VDC Auxiliary 587 Nuclear Sampling Room 36 1-IMO-910 Refueling Water Storage Tank to CVCS Charging Pumps Suction Header Train 'A' Motor Operated Shutoff Valve CVCS (Charging)

Auxiliary 587 Reciprocating Charging Pump Room 39 1-QMO-200 CVCS Charging to Regenerative Heat Exchanger Train 'A' Motor Operated Shutoff Valve CVCS (Charging)

Auxiliary 587 Reciprocating Charging Pump Room 39 1-QMO-201 CVCS Charging to Regenerative Heat Exchanger Train 'B' Motor Operated Shutoff Valve CVCS (Charging)

Auxiliary 587 Reciprocating Charging Pump Room 39 1-QRV-251 CVCS Centrifugal Charging Pumps Air Operated Discharge Flow Control Valve CVCS (Charging)

Auxiliary 587 Reciprocating Charging Pump Room 39 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page: 10 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-SV-56 CVCS Charging Pumps Suction Header Safety Valve CVCS (Charging)

Auxiliary 587 Reciprocating Charging Pump Room 39 1-HE-37E East Centrifugal Charging Pump Gear Oil Cooler Component Cooling Water Auxiliary 587 East Centrifugal Charging Pump Room 40 1-HE-38E East Centrifugal Charging Pump Bearing Oil Cooler Component Cooling Water Auxiliary 587 East Centrifugal Charging Pump Room 40 1-IMO-911 Refueling Water Storage Tank to CVCS Charging Pumps Suction Header Train 'B' Motor Operated Shutoff Valve CVCS (Charging)

Auxiliary 587 East Centrifugal Charging Pump Room 40 1-PP-50E East Centrifugal Charging Pump CVCS (Charging)

Auxiliary 587 East Centrifugal Charging Pump Room 40 1-QMO-225 East Centrifugal Charging Pump Mini-Flow to RCP Seal Water Heat Exchanger HE-11 Motor Operated Shutoff Valve CVCS (Charging)

Auxiliary 587 East Centrifugal Charging Pump Room 40 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page: 11 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-HE-37W West Centrifugal Charging Pump Gear Oil Cooler Component Cooling Water Auxiliary 587 West Centrifugal Charging Pump Room 41 1-HE-38W West Centrifugal Charging Pump Bearing Oil Cooler Component Cooling Water Auxiliary 587 West Centrifugal Charging Pump Room 41 1-IMO-360 Safety Injection Pumps to CVCS Charging Pumps Suction Header Crosstie Motor Operated Shutoff Valve CVCS (Charging)

Auxiliary 587 West Centrifugal Charging Pump Room 41 1-PP-50W West Centrifugal Charging Pump CVCS (Charging)

Auxiliary 587 West Centrifugal Charging Pump Room 41 1-QMO-226 West Centrifugal Charging Pump Mini-Flow to RCP Seal Water Heat Exchanger HE-11 Motor Operated Shutoff Valve CVCS (Charging)

Auxiliary 587 West Centrifugal Charging Pump Room 41 1-HE-34NE North Safety Injection Pump Mech Seal Heat Exchanger Component Cooling Water Auxiliary 587 North Safety Injection Pump Room 42 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page: 12 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-HE-34NW North Safety Injection Pump Mech Seal Heat Exchanger Component Cooling Water Auxiliary 587 North Safety Injection Pump Room 42 1-HE-35N North Safety Injection Pump Oil Cooler Component Cooling Water Auxiliary 587 North Safety Injection Pump Room 42 1-ICM-260 North Safety Injection Pump PP-26N Discharge Motor Operated Containment Isolation Valve Safety Injection Auxiliary 587 North Safety Injection Pump Room 42 1-IFI-260 Safety Injection Pump Discharge Flow Indicator Safety Injection Auxiliary 587 North Safety Injection Pump Room 42 1-IMO-262 Safety Injection Pumps Recirc to Refueling Water Storage Tank TK-33 Train 'A' Motor Operated Shutoff Valve Safety Injection Auxiliary 587 North Safety Injection Pump Room 42 1-IMO-263 Safety Injection Pumps Recirc to Refueling Water Storage Tank TK-33 Train 'B' Motor Operated Shutoff Valve Safety Injection Auxiliary 587 North Safety Injection Pump Room 42 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page: 13 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-IMO-270 Safety Injection Pumps Discharge Crosstie Train 'A' Motor Operated Shutoff Valve Safety Injection Auxiliary 587 North Safety Injection Pump Room 42 1-IMO-361 Safety Injection Pumps Suction to and From Charging Pumps Suction Train 'A' Motor Operated Shutoff Valve Safety Injection Auxiliary 587 North Safety Injection Pump Room 42 1-IMO-362 Safety Injection Pumps Suction to and From Charging Pumps Suction Train 'B' Motor Operated Shutoff Valve Safety Injection Auxiliary 587 North Safety Injection Pump Room 42 1-PP-26N North Safety Injection Pump Safety Injection Auxiliary 587 North Safety Injection Pump Room 42 1-SV-98N North Safety Injection Pump PP-26N Discharge Header Safety Valve Safety Injection Auxiliary 587 North Safety Injection Pump Room 42 1-HE-34SE South Safety Injection Pump Mech Seal Heat Exchanger Component Cooling Water Auxiliary 587 South Safety Injection Pump Room 43 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page: 14 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-HE-34SW South Safety Injection Pump Mech Seal Heat Exchanger Component Cooling Water Auxiliary 587 South Safety Injection Pump Room 43 1-HE-35S South Safety Injection Pump Oil Cooler Component Cooling Water Auxiliary 587 South Safety Injection Pump Room 43 1-ICM-265 South Safety Injection Pump PP-26S Discharge Motor Operated Containment Isolation Valve Safety Injection Auxiliary 587 South Safety Injection Pump Room 43 1-IFI-266 Safety Injection Pump Discharge Flow Indicator Safety Injection Auxiliary 587 South Safety Injection Pump Room 43 1-IMO-261 Refueling Water Storage Tank TK-33 Supply to Safety Injection Pumps Motor Operated Shutoff Valve Safety Injection Auxiliary 587 South Safety Injection Pump Room 43 1-IMO-275 Safety Injection Pumps Discharge Crosstie Train 'B' Motor Operated Shutoff Valve Safety Injection Auxiliary 587 South Safety Injection Pump Room 43 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page: 15 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-PP-26S South Safety Injection Pump Safety Injection Auxiliary 587 South Safety Injection Pump Room 43 1-SV-96 Safety Injection Pumps Suction Header Safety Valve Safety Injection Auxiliary 587 South Safety Injection Pump Room 43 1-SV-98S South Safety Injection Pump PP-26S Discharge Header Safety Valve Safety Injection Auxiliary 587 South Safety Injection Pump Room 43 1-FFC-220 Feedwater to Steam Generator #2 Channel I Flow Control Transmitter Feedwater Auxiliary 587 West Feedwater Regulating Valve Area 48 1-FFC-221 Feedwater to Steam Generator #2 Channel II Flow Control Transmitter Feedwater Auxiliary 587 West Feedwater Regulating Valve Area 48 1-FFC-230 Feedwater to Steam Generator #3 Channel I Flow Control Transmitter Feedwater Auxiliary 587 West Feedwater Regulating Valve Area 48 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page: 16 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-FFC-231 Feedwater to Steam Generator #3 Channel II Flow Control Transmitter Feedwater Auxiliary 587 West Feedwater Regulating Valve Area 48 1-FRV-220 Steam Generator OME-3-2 Feedwater Regulating Valve Feedwater Auxiliary 587 West Feedwater Regulating Valve Area 48 1-FRV-230 Steam Generator OME-3-3 Feedwater Regulating Valve Feedwater Auxiliary 612 West Feedwater Regulating Valve Area 48 1-XSO-293-1(2)

Steam Generator #2 Feedwater Regulating Valve FRV-220 Train 'A' Control Solenoids Control Air Auxiliary 587 West Feedwater Regulating Valve Area 48 1-XSO-294-1(2)

Steam Generator #2 Feedwater Regulating Valve FRV-220 Train 'B' Control Solenoids Control Air Auxiliary 587 West Feedwater Regulating Valve Area 48 1-XSO-295-1(2)

Steam Generator #3 Feedwater Regulating Valve FRV-230 Train 'A' Control Solenoids Control Air Auxiliary 587 West Feedwater Regulating Valve Area 48 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page: 17 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-XSO-296-1(2)

Steam Generator #3 Feedwater Regulating Valve FRV-230 Train 'B' Control Solenoids Control Air Auxiliary 587 West Feedwater Regulating Valve Area 48 1-FFS-258 Turbine Driven Auxiliary Feedwater Pump PP-4 Discharge Flow Switch Auxiliary Feedwater Turbine 591 TDAFP Room 49 1-FFS-259 Turbine Driven Auxiliary Feedwater Pump PP-4 Discharge Flow Switch Auxiliary Feedwater Turbine 591 TDAFP Room 49 1-FFS-260 Turbine Driven Auxiliary Feedwater Pump PP-4 Discharge Flow Switch Auxiliary Feedwater Turbine 591 TDAFP Room 49 1-FFS-261 Turbine Driven Auxiliary Feedwater Pump PP-4 Discharge Flow Switch Auxiliary Feedwater Turbine 591 TDAFP Room 49 1-FRV-256 Turbine Driven Auxiliary Feedwater Pump PP-4 Air Operated Test Valve Auxiliary Feedwater Turbine 591 TDAFP Room 49 1-FRV-258 Turbine Driven Auxiliary Feedwater Pump PP-4 Air Operated Emergency Leakoff Valve Auxiliary Feedwater Turbine 591 TDAFP Room 49 1-HV-AFP-T1AC Turbine Driven Auxiliary Feedwater Pump Room Cooler Turbine Building Ventilation Turbine 591 TDAFP Room 49 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page: 18 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-HV-AFP-T2AC Turbine Driven Auxiliary Feedwater Pump Room Cooler Turbine Building Ventilation Turbine 591 TDAFP Room 49 1-OME-33 Turbine Driven Auxiliary Feedwater Pump PP-4 Duplex Strainer Auxiliary Feedwater Turbine 591 TDAFP Room 49 1-OME-39 AFW Pump Turbine Main Steam Turbine 591 TDAFP Room 49 1-PP-4 Turbine Driven Auxiliary Feedwater Pump Auxiliary Feedwater Turbine 591 TDAFP Room 49 1-QT-506 TDAFP Trip Throttle Valve Main Steam Turbine 591 TDAFP Room 49 1-QT-507 TDAFP Governor Valve Main Steam Turbine 591 TDAFP Room 49 1-SV-140-1 Turbine Driven Auxiliary Feedwater Pump Governor Oil Cooler Cooling Water Inlet Safety Valve Auxiliary Feedwater Turbine 591 TDAFP Room 49 1-SV-140-2 Turbine Driven Auxiliary Feedwater Pump Oil Cooler Cooling Water Inlet Safety Valve Auxiliary Feedwater Turbine 591 TDAFP Room 49 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page: 19 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-VTS-203 Turbine Driven Auxiliary Feedwater Pump Room Cooler 1-HV-AFP-T1AC Temperature Switch Turbine Building Ventilation Turbine 591 TDAFP Room 49 1-VTS-204 Turbine Driven Auxiliary Feedwater Pump Room Cooler 1-HV-AFP-T2AC Temperature Switch Turbine Building Ventilation Turbine 591 TDAFP Room 49 1-XSO-256 Turbine Driven Auxiliary Feedwater Pump Test Valve FRV-256 Control Solenoid Auxiliary Feedwater Turbine 591 TDAFP Room 49 1-XSO-258 Turbine Driven Auxiliary Feedwater Pump Emergency Leakoff Valve FRV-258 Control Solenoid Auxiliary Feedwater Turbine 591 TDAFP Room 49 1-FFS-257 East Motor Driven Auxiliary Feedwater Pump PP-3E Discharge Flow Switch Auxiliary Feedwater Turbine 591 East Motor Driven Feed Pump Room 50 1-FRV-255 East Motor Driven Auxiliary Feedwater Pump PP-3E Air Operated Test Valve Auxiliary Feedwater Turbine 591 East MDAFP Room 50 1-FRV-257 East Motor Driven Auxiliary Feedwater Pump PP-3E Air Operated Emergency Leakoff Valve Auxiliary Feedwater Turbine 591 East MDAFP Room 50 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page: 20 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-HV-AFP-EAC East Motor Driven Auxiliary Feedwater Pump Room Cooler Turbine Building Ventilation Turbine 591 East MDAFP Room 50 1-OME-32E East Motor Driven Auxiliary Feedwater Pump PP-3E Duplex Strainer Auxiliary Feedwater Turbine 591 East MDAFP Room 50 1-PP-3E East Motor Driven Auxiliary Feedwater Pump Auxiliary Feedwater Turbine 591 East MDAFP Room 50 1-SV-169E East Motor Driven Auxiliary Feedwater Pump PP-3E Suction Safety Valve Auxiliary Feedwater Turbine 591 East MDAFP Room 50 1-VTS-201 East Motor Driven Auxiliary Feedwater Pump Room Cooler 1-HV-AFP-EAC Temperature Switch Turbine Building Ventilation Turbine 591 East MDAFP Room 50 1-XSO-255 Turbine Driven Auxiliary Feedwater Pump Test Valve FRV-255 Control Solenoid Auxiliary Feedwater Turbine 591 TDAFP Room 49 1-XSO-257 Turbine Driven Auxiliary Feedwater Pump Emergency Leakoff Valve FRV-257 Control Solenoid Auxiliary Feedwater Turbine 591 TDAFP Room 49 1-FFS-244 West Motor Driven Auxiliary Feedwater Pump PP-3W Discharge Flow Switch Auxiliary Feedwater Turbine 591 West MDAFP Room 51 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page: 21 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-FFS-245 West Motor Driven Auxiliary Feedwater Pump PP-3W Discharge Flow Switch Auxiliary Feedwater Turbine 591 West MDAFP Room 51 1-FFS-247 West Motor Driven Auxiliary Feedwater Pump PP-3W Discharge Flow Switch Auxiliary Feedwater Turbine 591 West MDAFP Room 51 1-FRV-245 West Motor Driven Auxiliary Feedwater Pump PP-3W Air Operated Test Valve Auxiliary Feedwater Turbine 591 West MDAFP Room 51 1-FRV-247 West Motor Driven Auxiliary Feedwater Pump PP-3W Air Operated Emergency Leakoff Valve Auxiliary Feedwater Turbine 591 West MDAFP Room 51 1-HV-AFP-WAC West Motor Driven Auxiliary Feedwater Pump Room Cooler Turbine Building Ventilation Turbine 591 West MDAFP Room 51 1-OME-32W West Motor Driven Auxiliary Feedwater Pump PP-3W Duplex Strainer Auxiliary Feedwater Turbine 591 West MDAFP Room 51 1-PP-3W West Motor Driven Auxiliary Feedwater Pump Auxiliary Feedwater Turbine 591 West MDAFP Room 51 1-SV-169W West Motor Driven Auxiliary Feed Pump PP-3W Suction Safety Valve Auxiliary Feedwater Turbine 591 West MDAFP Room 51 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page: 22 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-VTS-206 West Motor Driven Auxiliary Feedwater Pump Room Cooler1-HV-AFP-WAC Temperature Switch Turbine Building Ventilation Turbine 591 West MDAFP Room 51 1-XSO-345 West Motor Driven Auxiliary Feedwater Pump Test Valve FRV-245 Control Solenoid Auxiliary Feedwater Turbine 591 West MDAFP Room 51 1-XSO-347 West Motor Driven Auxiliary Feedwater Pump Emergency Leakoff Valve FRV-247 Control Solenoid Auxiliary Feedwater Turbine 591 West MDAFP Room 51 1-HE-32E East Residual Heat Removal Pump PP-35E Mechanical Seal Heat Exchanger Residual Heat Removal Auxiliary 573 East RHR Pump Room 54 1-IMO-310 East Residual Heat Removal Pump PP-35E Suction Motor Operated Shutoff Valve Residual Heat Removal Auxiliary 573 East RHR Pump Room 54 1-PP-35E East Residual Heat Removal Pump Residual Heat Removal Auxiliary 573 East RHR Pump Room 54 1-HE-32W West Residual Heat Removal Pump PP-35W Mechanical Seal Heat Exchanger Component Cooling Water Auxiliary 573 West RHR Pump Room 55 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 29.0 Table:14.4.2-1A Part 2 of 6 Page: 23 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-IMO-320 West Residual Heat Removal Pump PP-35W Suction Motor Operated Shutoff Valve Residual Heat Removal Auxiliary 573 West RHR Pump Room 55 1-PP-35W West Residual Heat Removal Pump Residual Heat Removal Auxiliary 573 West RHR Pump Room 55 1-IFI-53 Boron Injection to Reactor Coolant Loop

  1. 3 Flow Indicator Transmitter Boron Injection Containment 598 Annulus -

Quadrant #3 56 1-IMO-53 Boron Injection to Reactor Coolant Loop

  1. 3 Motor Operated Shutoff Valve Boron Injection Containment 598 Annulus -

Quadrant #3 56 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page:

1 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-MFC-130 Steam Generator OME-3-3 Channel II Steam Flow Control Transmitter Main Steam Containment 598 Annulus -

Quadrant #3 56 1-MFC-131 Steam Generator OME-3-3 Channel I Steam Flow Control Transmitter Main Steam Containment 598 Annulus -

Quadrant #3 56 1-SV-50 RC Pumps Seal #1 and Startup Seal System Bypass to Seal Water Return Filters Safety Valve Reactor Coolant (Pump Seal Water Inj/Leakoff)

Containment 598 Annulus -

Quadrant #3 56 1-XSO-27 Reactor Coolant Pump #3 Seal #1 Leakoff to RCP Seal Water Return Filter Air Operated Shutoff Valve QRV-30 Control Solenoid Control Air Containment 598 Annulus -

Quadrant #3 56 1-IFI-54 Boron Injection to Reactor Coolant Loop

  1. 4 Flow Indicator Transmitter Boron Injection Containment 598 Annulus -

Quadrant #4 57 1-IMO-54 Boron Injection to Reactor Coolant Loop

  1. 4 Motor Operated Shutoff Valve Boron Injection Containment 598 Annulus -

Quadrant #4 57 1-MFC-140 Steam Generator OME-3-4 Channel I Steam Flow Control Transmitter Main Steam Containment 598 Annulus -

Quadrant #4 57 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page:

2 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-33-QCR-301 Reactor Coolant Letdown Train A Containment Isolation Valve QCR-301 Limit Switch 250vdc Control and Instrumentation Containment 598 Annulus -

Quadrant #1 58 1-IFI-51 Boron Injection to Reactor Coolant Loop

  1. 1 Flow Indicator Transmitter Boron Injection Containment 598 Annulus -

Quadrant #1 58 1-IMO-51 Boron Injection to Reactor Coolant Loop

  1. 1 Motor Operated Shutoff Valve Boron Injection Containment 598 Annulus -

Quadrant #1 58 1-MFC-110 Steam Generator OME-3-1 Channel I Steam Flow Control Transmitter Main Steam Containment 598 Annulus -

Quadrant #1 58 1-MFC-111 Steam Generator OME-3-1 Channel II Steam Flow Control Transmitter Main Steam Containment 598 Annulus -

Quadrant #1 58 1-MFC-141 Steam Generator OME-3-4 Channel II Steam Flow Control Transmitter Main Steam Containment 598 Annulus -

Quadrant #1 58 1-XSO-25 Reactor Coolant Pump #1 Seal #1 Leakoff to RCP Seal Water Return Filter Air Operated Shutoff Valve QRV-10 Control Solenoid Control Air Containment 598 Annulus -

Quadrant #1 58 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page:

3 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-33-IRV-60 Safety Injection to Accumulator Fill Line Control Valve IRV-60 Limit Switch 250VDC Control and Instrumentation Containment 598 Annulus -

Quadrant #2 59 1-33-QRV-150 RCP Startup Seal System Bypass to Seal Water Return Filter Shutoff Valve QRV-150 Limit Switch 250VDC Control and Instrumentation Containment 598 Annulus -

Quadrant #2 59 1-ICM-111 RHR to Reactor Coolant Loops #2 & #3 Cold Legs Motor Operated Containment Isolation Valve Residual Heat Removal Containment 598 Annulus -

Quadrant #2 59 1-ICM-129 Reactor Coolant Loop #2 Hot Leg to Residual Heat Removal Pumps Suction Motor Operated Containment Isolation Valve Residual Heat Removal Containment 598 Annulus -

Quadrant #2 59 1-IFI-52 Boron Injection to Reactor Coolant Loop

  1. 2 Flow Indicator Transmitter Boron Injection Containment 598 Annulus -

Quadrant #2 59 1-IMO-52 Boron Injection to Reactor Coolant Loop

  1. 2 Motor Operated Shutoff Valve Boron Injection Containment 598 Annulus -

Quadrant #2 59 1-IRV-60 Safety Injection to Accumulator Fill Line Air Operated Control Valve Safety Injection Containment 598 Annulus -

Quadrant #2 59 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page:

4 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-MFC-120 Steam Generator OME-3-2 Channel II Steam Flow Control Transmitter Main Steam Containment 598 Annulus -

Quadrant #2 59 1-MFC-121 Steam Generator OME-3-2 Channel I Steam Flow Control Transmitter Main Steam Containment 598 Annulus -

Quadrant #2 59 1-QCM-250 Reactor Coolant Pump Seal Water Return Train 'A' Containment Isolation Motor Operated Valve CVCS (Charging)

Containment 598 Annulus -

Quadrant #2 59 1-QCR-301 CVCS Letdown Isolation CVCS (Letdown)

Containment 598 Annulus -

Quadrant #2 59 1-QRV-150 Reactor Coolant Pumps Startup Seal System Bypass to Seal Water Return Filter QC-109 0.75" Air Operated Shutoff Valve Reactor Coolant (Pump Seal Water Inj/Leakoff)

Containment 598 Annulus -

Quadrant #2 59 1-SV-102 Residual Heat Removal to Reactor Coolant Loops #2 & #3 Cold Legs Safety Valve Residual Heat Removal Containment 598 Annulus -

Quadrant #2 59 1-SV-103 Reactor Coolant Loop #2 Hot Leg to Residual Heat Removal Pumps Safety Valve Residual Heat Removal Containment 598 Annulus -

Quadrant #2 59 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page:

5 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-XSO-166 Safety Injection to Accumulator Fill Line Control Valve IRV-60 Control Solenoid Control Air Containment 598 Annulus -

Quadrant #2 59 1-XSO-250 Reactor Coolant Pumps Startup Seal System Bypass to Seal Water Return Filter Air Operated Shutoff Valve QRV-150 Control Solenoid Control Air Containment 598 Annulus -

Quadrant #2 59 1-XSO-26 Reactor Coolant Pump #2 Seal #1 Leakoff to RCP Seal Water Return Filter Air Operated Shutoff Valve QRV-20 Control Solenoid Control Air Containment 598 Annulus -

Quadrant #2 59 1-33-QRV-10 Reactor Coolant Pump #1 Seal #1 Leakoff to RCP Seal Water Return Filter Shutoff Valve QRV-10 Limit Switch 250VDC Control and Instrumentation Containment 617 Lower Containment, Quadrant #1 60 1-OME-3-1 Steam Generator No. 1 Main Steam Containment 609 Lower Containment, Quadrant #1 60 1-QRV-10 Reactor Coolant Pump #1 Seal #1 Leakoff to RCP Seal Water Return Filter QC-109 2" Air Operated Shutoff Valve Reactor Coolant (Pump Seal Water Inj/Leakoff)

Containment 617 Lower Containment, Quadrant #1 60 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page:

6 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-33-QRV-20 Reactor Coolant Pump #2 Seal #1 Leakoff to RCP Seal Water Return Filter Shutoff Valve QRV-20 Limit Switch 250VDC Control and Instrumentation Containment 625 Lower Containment, Quadrant #2 61 1-IMO-128 Reactor Coolant Loop #2 Hot Leg to Residual Heat Removal Pumps Suction Motor Operated Shutoff Valve Residual Heat Removal Containment 617 Lower Containment, Quadrant #2 61 1-OME-3-2 Steam Generator No. 2 Main Steam Containment 609 Lower Containment, Quadrant #2 61 1-QRV-20 Reactor Coolant Pump #2 Seal #1 Leakoff to RCP Seal Water Return Filter QC-109 2" Air Operated Shutoff Valve Reactor Coolant (Pump Seal Water Inj/Leakoff)

Containment 625 Lower Containment, Quadrant #2 61 1-33-QRV-30 Reactor Coolant Pump #3 Seal #1 Leakoff to RCP Seal Water Return Filter Shutoff Valve QRV-30 Limit Switch 250VDC Control and Instrumentation Containment 612 Lower Containment, Quadrant #3 62 1-OME-3-3 Steam Generator No. 3 Main Steam Containment 609 Lower Containment, Quadrant #3 62 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page:

7 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-QRV-30 Reactor Coolant Pump #3 Seal #1 Leakoff to RCP Seal Water Return Filter QC--09 2" Air Operated Shutoff Globe Valve Reactor Coolant (Pump Seal Water Inj/Leakoff)

Containment 612 Lower Containment, Quadrant #3 62 1-TK-253-1 Pressurizer Train 'B' Pressure Relief Valve NRV-152 Reserve Control Air Tank Control Air Containment 625 Lower Containment, Quadrant #3 62 1-TK-253-2 Pressurizer Train 'A' Pressure Relief Valve NRV-153 Reserve Control Air Tank Control Air Containment 625 Lower Containment, Quadrant #3 62 1-33-QRV-40 Reactor Coolant Pump #4 Seal #1 Leakoff to RCP Seal Water Return Filter Shutoff Valve QRV-40 Limit Switch 250VDC Control and Instrumentation Containment 612 Lower Containment, Quadrant #4 63 1-CA-554 Containment 85 PSI Control Air Ring Header #2 to Control Valve NRV-153 Check Valve Control Air Containment 625 Lower Containment, Quadrant #4 63 1-CA-565 Containment 85 PSI Control Air Ring Header #2 to Control Valve NRV-152 Check Valve Control Air Containment 625 Lower Containment, Quadrant #4 63 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page:

8 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-OME-3-4 Steam Generator No. 4 Main Steam Containment 609 Lower Containment, Quadrant #4 63 1-QRV-40 Reactor Coolant Pump #4 Seal #1 Leakoff to RCP Seal Water Return Filter QC-109 2" Air Operated Shutoff Globe Valve Reactor Coolant (Pump Seal Water Inj/Leakoff)

Containment 612 Lower Containment, Quadrant #4 63 1-NRI-21 Nuclear Instrumentation Channel I Wide Range Radiation Detector Nuclear Instrumentation Containment 621 Reactor Vessel Head Area 64 1-XSO-28 Reactor Coolant Pump #4 Seal #1 Leakoff to RCP Seal Water Return Filter Air Operated Shutoff Valve QRV-40 Control Solenoid Control Air Containment 612 Regenerative Heat Exchanger Room 66 1-NLI-151 Pressurizer OME-4 Level Indicator Transmitter Reactor Coolant Containment 612 Instrumentation Room 67 1-NLP-151 Pressurizer OME-4 Protection Channel I Level Transmitter Reactor Coolant Containment 612 Instrumentation Room 67 1-NLP-152 Pressurizer OME-4 Protection Channel II Level Transmitter Reactor Coolant Containment 612 Instrumentation Room 67 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page:

9 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-NLP-153 Pressurizer OME-4 Protection Channel III Level Transmitter Reactor Coolant Containment 612 Instrumentation Room 67 1-NPP-151 Pressurizer OME-4 Protection Channel I Pressure Transmitter Reactor Coolant Containment 612 Instrumentation Room 67 1-NPP-152 Pressurizer OME-4 Protection Channel II Pressure Transmitter Reactor Coolant Containment 612 Instrumentation Room 67 1-NPP-153 Pressurizer OME-4 Protection Channel III Pressure Transmitter Reactor Coolant Containment 612 Instrumentation Room 67 1-NPS-153 Pressurizer OME-4 Protection Channel IV Pressure Transmitter Reactor Coolant Containment 612 Instrumentation Room 67 1-BLP-110 Steam Generator OME-3-1 Channel 4 Reactor Protection Input Narrow Range Level Transmitter Main Steam (SG)

Containment 612 Accumulator Tank #1 Area 68 1-BLI-120 Steam Generator OME-3-2 Wide Range Level Indicator Transmitter Main Steam (SG)

Containment 612 Accumulator Tank #2 Area 69 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page: 10 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-BLP-120 Steam Generator OME-3-2 Channel 4 Reactor Protection Input Narrow Range Level Transmitter Main Steam (SG)

Containment 612 Accumulator Tank #2 Area 69 1-BLP-122 Steam Generator OME-3-2 Channel 3 Reactor Protection Input Narrow Range Level Transmitter Main Steam (SG)

Containment 612 Accumulator Tank #2 Area 69 1-BLP-131 Steam Generator OME-3-3 Channel 1 Reactor Protection Input Narrow Range Level Transmitter Main Steam (SG)

Containment 612 Accumulator Tank #3 Area 70 1-BLI-140 Steam Generator OME-3-4 Wide Range Level Indicator Transmitter Main Steam (SG)

Containment 612 Accumulator Tank #4 Area 71 1-BLP-140 Steam Generator OME-3-4 Channel 4 Reactor Protection Input Narrow Range Level Transmitter Main Steam (SG)

Containment 612 Accumulator Tank #4 Area 71 1-BLP-142 Steam Generator OME-3-4 Channel 3 Reactor Protection Input Narrow Range Level Transmitter Main Steam (SG)

Containment 612 Accumulator Tank #4 Area 71 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page: 11 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-BLI-110 Steam Generator OME-3-1 Wide Range Level Indicator Transmitter Main Steam (SG)

Containment 612 East Containment Lower Vent Room 72 1-BLP-111 Steam Generator OME-3-1 Channel 2 Reactor Protection Input Narrow Range Level Transmitter Main Steam (SG)

Containment 612 East Containment Lower Vent Room 72 1-BLP-112 Steam Generator OME-3-1 Channel 3 Reactor Protection Input Narrow Range Level Transmitter Main Steam (SG)

Containment 612 East Containment Lower Vent Room 72 1-BLP-141 Steam Generator OME-3-4 Channel 2 Reactor Protection Input Narrow Range Level Transmitter Main Steam (SG)

Containment 612 East Containment Lower Vent Room 72 1-IMO-315 East RHR and North Safety Injection to Reactor Coolant Loops #1 and #4 Hot Legs Motor Operated Shutoff Valve Residual Heat Removal Containment 612 East Containment Lower Vent Room 72 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page: 12 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-IMO-316 East RHR and North Safety Injection to Reactor Coolant Loops #1 and #4 Cold Legs Motor Operated Shutoff Valve Residual Heat Removal Containment 612 East Containment Lower Vent Room 72 1-NPS-122 Reactor Coolant Loop #1 Hot Leg Wide Range Pressure Transmitter Reactor Coolant Containment 612 East Containment Lower Vent Room 72 1-SI-152N RHR to SI Pumps Check Valve Residual Heat Removal Containment 612 East Containment Lower Vent Room 72 1-BLI-130 Steam Generator OME-3-3 Wide Range Level Indicator Transmitter Main Steam (SG)

Containment 612 West Containment Lower Vent Room 73 1-BLP-121 Steam Generator OME-3-2 Channel 1 Reactor Protection Input Narrow Range Level Transmitter Main Steam (SG)

Containment 612 West Containment Lower Vent Room 73 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page: 13 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-BLP-130 Steam Generator OME-3-3 Channel 4 Reactor Protection Input Narrow Range Level Transmitter Main Steam (SG)

Containment 612 West Containment Lower Vent Room 73 1-BLP-132 Steam Generator OME-3-3 Channel 3 Reactor Protection Input Narrow Range Level Transmitter Main Steam (SG)

Containment 612 West Containment Lower Vent Room 73 1-IMO-325 West RHR and South Safety Injection to Reactor Coolant Loops #2 and #3 Hot Legs Motor Operated Shutoff Valve Residual Heat Removal Containment 612 West Containment Lower Vent Room 73 1-IMO-326 West RHR and South Safety Injection to Reactor Coolant Loops #2 and #3 Cold Legs Motor Operated Shutoff Valve Residual Heat Removal Containment 612 West Containment Lower Vent Room 73 1-NPS-121 Reactor Coolant Loop #2 Hot Leg Wide Range Pressure Transmitter Reactor Coolant Containment 612 West Containment Lower Vent Room 73 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page: 14 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-SI-152S RHR to SI Pumps Check Valve Residual Heat Removal Containment 612 West Containment Lower Vent Room 73 1-XSO-320 CVCS Letdown Isolation Valve QCR-301 Control Solenoid Control Air Containment 612 Hv-Ceq-2 Fan Room 74 1-33-NRV-151 Pressurizer Train B Pressure Relief Valve NRV-151 Limit Switch 250VDC Control and Instrumentation Containment 650 Pressurizer Enclosure, Interior 81 1-33-NRV-152 Pressurizer Train B Pressure Relief Valve NRV-152 Limit Switch 250VDC Control and Instrumentation Containment 650 Pressurizer Enclosure, Interior 81 1-33-NRV-153 Pressurizer Train A Pressure Relief Valve NRV-153 Limit Switch 250VDC Control and Instrumentation Containment 650 Pressurizer Enclosure, Interior 81 1-NMO-151 Pressurizer Relief Valve NRV-151 Upstream Motor Operated Shutoff Valve Reactor Coolant Containment 650 Pressurizer Enclosure, Interior 81 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page: 15 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-NMO-152 Pressurizer Relief Valve NRV-152 Upstream Motor Operated Shutoff Valve Reactor Coolant Containment 650 Pressurizer Enclosure, Interior 81 1-NMO-153 Pressurizer Relief Valve NRV-153 Upstream Motor Operated Shutoff Valve Reactor Coolant Containment 650 Pressurizer Enclosure, Interior 81 1-NRV-151 Pressurizer Train 'B' Pressure Relief Valve Reactor Coolant Containment 650 Pressurizer Enclosure, Interior 81 1-NRV-152 Pressurizer Train 'B' Pressure Relief Valve Reactor Coolant Containment 650 Pressurizer Enclosure, Interior 81 1-NRV-153 Pressurizer OME-4 Train 'A' Pressure Relief Valve Reactor Coolant Containment 650 Pressurizer Enclosure, Interior 81 1-NS0-62 Pressurizer OME-4 Post Accident Vent Train 'A' Solenoid Valve Reactor Coolant Containment 650 Pressurizer Enclosure, Interior 81 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page: 16 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-NSO-61 Post Accident Vent Valve Reactor Coolant Containment 650 Pressurizer Enclosure, Interior 81 1-NSO-63 Post Accident Vent Valve Reactor Coolant Containment 650 Pressurizer Enclosure, Interior 81 1-NSO-64 Pressurizer OME-4 Post Accident Vent Train 'B' Solenoid Valve Reactor Coolant Containment 650 Pressurizer Enclosure, Interior 81 1-SV-45A Pressurizer OME-4 Safety Valve 'A' Reactor Coolant Containment 650 Pressurizer Enclosure, Interior 81 1-SV-45B Pressurizer OME-4 Safety Valve 'B' Reactor Coolant Containment 650 Pressurizer Enclosure, Interior 81 1-SV-45C Pressurizer OME-4 Safety Valve 'C' Reactor Coolant Containment 650 Pressurizer Enclosure, Interior 81 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page: 17 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-XSO-503 Pressurizer Train 'B' Pressure Relief Valve NRV-151 Control Solenoid Control Air Containment 650 Pressurizer Enclosure, Interior 81 1-XSO-505 Pressurizer Train 'B' Pressure Relief Valve NRV-152 Control Solenoid Control Air Containment 652 Pressurizer Enclosure, Interior 81 1-XSO-507 Pressurizer Train 'A' Pressure Relief Valve NRV-153 Control Solenoid Control Air Containment 652 Pressurizer Enclosure, Interior 81 1-FFS-254 East Motor Driven Auxiliary Feedwater Pump PP-3E Discharge Flow Switch Auxiliary Feedwater Turbine 591 Auxiliary Feed Pump East Hallway 83 1-FFS-255 East Motor Driven Auxiliary Feedwater Pump PP-3E Discharge Flow Switch Auxiliary Feedwater Turbine 591 Auxiliary Feed Pump East Hallway 83 1-TK-253-3 Pressurizer Train 'B' Pressure Relief Valve NRV-152 Emergency Air Tank Control Air Containment 650 Upper Containment, Quadrant #4 86 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page: 18 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-TK-253-4 Pressurizer Train 'A' Pressure Relief Valve NRV-153 Emergency Air Tank Control Air Containment 650 Upper Containment, Quadrant #4 86 1-XRV-152 Backup Air to 1-NRV-152 Pressure Regulator Valve Control Air Containment 650 Upper Containment, Quadrant #4 86 1-XRV-153 Backup Air to 1-NRV-153 Pressure Regulator Valve Control Air Containment 650 Upper Containment, Quadrant #4 86 1-XRV-154 Backup Air to 1-NRV-152 Low Pressure Trip Valve Control Air Containment 650 Upper Containment, Quadrant #4 86 1-XRV-155 Backup Air to 1-NRV-152 Positive Air Shutoff Valve Control Air Containment 650 Upper Containment, Quadrant #4 86 1-XRV-156 Backup Air to 1-NRV-153 Low Pressure Trip Valve Control Air Containment 650 Upper Containment, Quadrant #4 86 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page: 19 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-XRV-157 Backup Air to 1-NRV-153 Positive Air Shutoff Valve Control Air Containment 650 Upper Containment, Quadrant #4 86 1-NRI-23 Nuclear Instrumentation Channel III Source Range Radiation Detector Nuclear Instrumentation Containment 626 Reactor Cavity 105 1-20-SV-1-AB Solenoid Valve to POV-1-AB Compressed Air Auxiliary 587 AB EDG Room 121 1-20-SV-2-AB Solenoid Valve to POV-2-AB Compressed Air Auxiliary 587 AB EDG Room 121 1-20-SV-3-AB Solenoid Valve to XRV-220 Compressed Air Auxiliary 587 AB EDG Room 121 1-ABD-A 600VAC Motor Control Center ABD-A 600VAC Auxiliary 587 AB EDG Room 121 1-ABD-B 600VAC Motor Control Center ABD-B 600VAC Auxiliary 587 AB EDG Room 121 1-CPS-312 AB Emergency Diesel Jacket Water Pump QT-130-AB1 Discharge Pressure Switch Diesel Jacket Water Auxiliary 587 AB EDG Room 121 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page: 20 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-CPS-314 AB Emergency Diesel Jacket Water Pump QT-130-AB2 Discharge Pressure Switch Diesel Jacket Water Auxiliary 587 AB EDG Room 121 1-DG-101A AB Emergency Diesel Starting Air Compressor QT-142-AB2 Outlet Check Valve Diesel Starting Air Auxiliary 587 AB EDG Room 121 1-DG-103A AB Emergency Diesel Starting Air Compressor QT-142-AB1 Outlet Check Valve Diesel Starting Air Auxiliary 587 AB EDG Room 121 1-DGAB AB Emergency Diesel Generator OME-150-AB Control Subpanel Diesel Generator, Control and Instrumentation Auxiliary 587 AB EDG Room 121 1-DGAB-FFCKT AB Emergency Diesel Generator OME-150-AB Field Flash Circuit Transformer Diesel Generator, Control and Instrumentation Auxiliary 587 AB EDG Room 121 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page: 21 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-DGAB-INV AB Emergency Diesel Generator OME-150-AB Inverter Diesel Generator, Control and Instrumentation Auxiliary 587 AB EDG Room 121 1-DGABX OME-150-CD Auxiliary Subpanel Diesel Generator, Control and Instrumentation Auxiliary 587 AB EDG Room 121 1-ELSC 120/128 VAC Emergency Local Shutdown Distribution Panel 120/208VAC Misc Safety Related Power Distribution Auxiliary 587 AB EDG Room 121 1-ELSCX 120/208VAC Emergency Local Shutdown Auxiliary Distribution Panel 120/208VAC Misc Safety Related Power Distribution Auxiliary 587 AB EDG Room 121 1-HE-47-ABN AB Emergency Diesel North Combustion Air Aftercooler Diesel Combustion Air Auxiliary 587 AB EDG Room 121 1-HE-47-ABS AB Emergency Diesel South Combustion Air Aftercooler Diesel Combustion Air Auxiliary 587 AB EDG Room 121 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page: 22 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-HE-55-AB Governor Oil Cooler For AB Emergency Diesel Engine Diesel Jacket Water Auxiliary 587 AB EDG Room 121 1-HV-DDP-AB1 AB Emergency Diesel Generator Room Ventilation Exhaust Fan HV-DGX-1 Tempering Air Damper Diesel Room Ventilation Auxiliary 587 AB EDG Room 121 1-HV-DDP-AB2 AB Emergency Diesel Generator Room Ventilation Supply Fan HV-DGS-1 Tempering Air Damper Diesel Room Ventilation Auxiliary 587 AB EDG Room 121 1-HV-DGS-2 CD Emergency Diesel Generator Room Ventilation Supply Fan Diesel Room Ventilation Auxiliary 587 AB EDG Room 121 1-HV-DGS-3 AB Emergency Diesel Generator Room Cabinet Ventilation Supply Fan Diesel Room Ventilation Auxiliary 587 AB EDG Room 121 1-HV-DGX-1 AB Emergency Diesel Generator Room Ventilation Exhaust Fan Diesel Room Ventilation Auxiliary 587 AB EDG Room 121 1-LLS-120 AB Emergency Diesel Fuel Oil Day Tank QT-107-AB High Level Switch #1 Diesel Fuel Oil Auxiliary 587 AB EDG Room 121 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 3 of 6 Page: 23 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-LLS-121 AB Emergency Diesel Fuel Oil Day Tank QT-107-AB Low Level Switch #1 Diesel Fuel Oil Auxiliary 587 AB EDG Room 121 1-LLS-122 AB Emergency Diesel Fuel Oil Day Tank QT-107-AB High Level Switch #2 Diesel Fuel Oil Auxiliary 587 AB EDG Room 121 1-LLS-123 AB Emergency Diesel Fuel Oil Day Tank QT-107-AB Low Level Switch #2 Diesel Fuel Oil Auxiliary 587 AB EDG ROOM 121 1-LRV-240 AB Emergency Diesel Upper Valve Gear Lube Oil Regulator #1 Diesel Lube Oil Auxiliary 587 AB EDG Room 121 1-LRV-241 AB Emergency Diesel Upper Valve Gear Lube Oil Regulator #2 Diesel Lube Oil Auxiliary 587 AB EDG Room 121 1-LSO-240 AB Emergency Diesel Upper Valve Gear Lubrication Control Solenoid #1 Diesel Lube Oil Auxiliary 587 AB EDG Room 121 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page:

1 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-LSO-241 AB Emergency Diesel Upper Valve Gear Lubrication Control Solenoid #2 Diesel Lube Oil Auxiliary 587 AB EDG Room 121 1-OME-150-AB AB Emergency Diesel Generator Diesel Generator, Control and Instrumentation Auxiliary 587 AB EDG Room 121 1-POV-1-AB Starting Air Syst/Pilot Operated 4-Way Valve For Air Start of XRVS For Diesel Engine Compressed Air Auxiliary 587 AB EDG Room 121 1-POV-2-AB Starting Air Syst/Pilot Operated 4-Way Valve For Air Start of XRVS For Diesel Engine Compressed Air Auxiliary 587 AB EDG Room 121 1-PP-120-AB Engine Driven Pump Diesel Fuel Oil Auxiliary 587 AB EDG Room 121 1-PP-122-AB Engine Driven Lube Oil Pump Diesel Lube Oil Auxiliary 587 AB EDG Room 121 1-PRV-1-AB Pressure Regulator For Starting Air Solenoid 20-SV-1-AB Compressed Air Auxiliary 587 AB EDG Room 121 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page:

2 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-PRV-1-CD Pressure Regulator For Starting Air Solenoid 20-SV-1-CD Compressed Air Auxiliary 587 AB EDG Room 121 1-QT-101-AB AB Emergency Diesel Air Intake Silencer Diesel Combustion Air Auxiliary 587 AB EDG Room 121 1-QT-107-AB AB Emergency Diesel Fuel Oil Day Tank Diesel Fuel Oil Auxiliary 587 AB EDG Room 121 1-QT-110-AB AB Emergency Diesel Lube Oil Cooler Diesel Lube Oil Auxiliary 587 AB EDG Room 121 1-QT-114-AB AB Emergency Diesel Lube Oil Cooler QT-110-AB Lube Oil Thermostatic Inlet/Bypass Valve Diesel Lube Oil Auxiliary 587 AB EDG Room 121 1-QT-130-AB1 AB Emergency Diesel Jacket Water Pump #1 Diesel Jacket Water Auxiliary 587 AB EDG Room 121 1-QT-130-AB2 AB Emergency Diesel Jacket Water Pump #2 Diesel Jacket Water Auxiliary 587 AB EDG Room 121 1-QT-131-AB AB Emergency Diesel Jacket Water Cooler Diesel Jacket Water Auxiliary 587 AB EDG Room 121 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page:

3 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-QT-132-AB AB Emergency Diesel Jacket Water Cooler QT-131-AB Thermostatic Inlet/Bypass Valve Diesel Jacket Water Auxiliary 587 AB EDG Room 121 1-QT-133-AB Ab Emergency Diesel Jacket Water Surge Tank Diesel Jacket Water Auxiliary 587 AB EDG Room 121 1-QT-135-AB AB Emergency Diesel Auxiliary Jacket Water Pump Diesel Jacket Water Auxiliary 587 AB EDG Room 121 1-QT-141-AB1 AB Emergency Diesel Starting Air Receiver #1 Diesel Starting Air Auxiliary 587 AB EDG Room 121 1-QT-141-AB2 AB Emergency Diesel Starting Air Receiver #2 Diesel Starting Air Auxiliary 587 AB EDG Room 121 1-QT-143-AB1 AB Emergency Diesel Control Air Dryer #1 Diesel Control Air Auxiliary 587 AB EDG Room 121 1-QT-143-AB2 AB Emergency Diesel Control Air Dryer #2 Diesel Control Air Auxiliary 587 AB EDG Room 121 1-QT-144-AB AB Emergency Diesel Fuel Oil Transfer Filter Diesel Fuel Oil Auxiliary 587 AB EDG Room 121 1-QT-502-AB AB Emergency Diesel Turbocharger Diesel Combustion Air Auxiliary 587 AB EDG Room 121 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page:

4 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-SV-120-AB 1-XTC-301 & 1-XTC-302 Control Air Safety Valve Control Air Auxiliary 587 AB EDG Room 121 1-SV-139-AB AB Emergency Diesel Starting Air to Turbocharger Safety Valve Diesel Starting Air Auxiliary 587 AB EDG Room 121 1-SV-200-AB AB Emergency Diesel Fuel Oil Manifolds to Fuel Oil Day Tank Safety Valve Diesel Fuel Oil Auxiliary 587 AB EDG Room 121 1-SV-201-AB2 AB Emergency Diesel Rear Bank Fuel Oil Manifold Safety Valve Diesel Fuel Oil Auxiliary 587 AB EDG Room 121 1-SV-216-AB AB Engine Driven Lube Oil Pump PP-122-AB Integral Relief Valve Diesel Lube Oil Auxiliary 587 AB EDG Room 121 1-SV-61-AB AB Emergency Diesel Auxiliary Jacket Water Heater QT-134-AB Safety Valve Diesel Jacket Water Auxiliary 587 AB EDG Room 121 1-SV-78-AB1 AB Emergency Diesel Starting Air Receiver QT-141-AB1 Safety Valve Diesel Starting Air Auxiliary 587 AB EDG Room 121 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page:

5 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-SV-78-AB2 AB Emergency Diesel Starting Air Receiver QT-141-AB2 Safety Valve Diesel Starting Air Auxiliary 587 AB EDG Room 121 1-SV-79-AB1 AB Emergency Diesel Control Air Dryer QT-143-AB1 Safety Valve Diesel Starting Air Auxiliary 587 AB EDG Room 121 1-SV-79-AB2 AB Emergency Diesel Control Air Dryer QT-143-AB2 Safety Valve Diesel Starting Air Auxiliary 587 AB EDG Room 121 1-TR-ELSC 120/208VAC Emergency Local Shutdown Distribution Transformer 120/208VAC Misc Safety Related Power Distribution Auxiliary 587 AB EDG Room 121 1-VTS-341 AB Emergency Diesel Generator Room Ventilation Exhaust FAN HV-DGX-1 Thermostat Diesel Room Ventilation Auxiliary 587 AB EDG Room 121 1-WRV-721 AB Emergency Diesel South Combustion Air Aftercooler HE ABS ESW Inlet/Bypass Valve Essential Service Water Auxiliary 587 AB EDG Room 121 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page:

6 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-WRV-723 AB Emergency Diesel North Combustion Air Aftercooler HE ABN ESW Inlet/Bypass Valve Essential Service Water Auxiliary 587 AB EDG Room 121 1-XPS-300 Diesel Combustion Air/AB Front Bank Air Chest Extreme High Pressure Switch Diesel Combustion Air Auxiliary 587 AB EDG Room 121 1-XRV-220 AB Emergency Diesel Starting Air Jet Assist Control Valve Diesel Starting Air Auxiliary 587 AB EDG Room 121 1-XRV-221 AB Emergency Diesel Front Bank Starting Air Shutoff Valve Diesel Starting Air Auxiliary 587 AB EDG Room 121 1-XRV-222 AB Emergency Diesel Rear Bank Starting Air Shutoff Valve Diesel Starting Air Auxiliary 587 AB EDG Room 121 1-XRV-223 AB Emergency Diesel Starting Air to Turbocharger Pressure Reducing Valve Diesel Starting Air Auxiliary 587 AB EDG Room 121 1-XRV-225 CD Emergency Diesel Starting Air Jet Assist Control Valve Diesel Starting Air Auxiliary 587 CD EDG Room 121 1-XRV-231 AB Emergency Diesel Starting Air to Control Air Dryer #1 Pressure Reducing Valve Diesel Starting Air Auxiliary 587 AB EDG Room 121 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page:

7 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-XRV-232 AB Emergency Diesel Starting Air to Control Air Dryer #2 Pressure Reducing Valve Diesel Starting Air Auxiliary 587 AB EDG Room 121 1-XRV-240 1-XTC-301 and 1-XTC-302 Control Air Pressure Reducing Valve (AB)

Diesel Control Air Auxiliary 587 AB EDG Room 121 QC-225-AB Duplex Engine Fuel Oil Filter Diesel Fuel Oil Auxiliary 587 AB EDG Room 121 1-20-SV-1-CD Solenoid Valve to POV-1-CD Compressed Air Auxiliary 587 CD EDG Room 122 1-20-SV-2-CD Solenoid Valve to POV-2-CD Compressed Air Auxiliary 587 CD EDG Room 122 1-20-SV-3-CD Solenoid Valve to XRV-225 Compressed Air Auxiliary 587 CD EDG Room 122 1-ABD-C 600VAC Motor Control Center ABD-C 600VAC Auxiliary 587 CD EDG Room 122 1-ABD-D 600VAC Motor Control Center ABD-D 600VAC Auxiliary 587 CD EDG Room 122 1-AFW 120/208VAC Distribution Panel 120/208VAC Misc Safety Related Power Distribution Auxiliary 587 CD EDG Room 122 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page:

8 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-AFWX 120/208VAC Auxiliary Distribution Panel 120/208VAC Misc Safety Related Power Distribution Auxiliary 587 CD EDG Room 122 1-CPS-317 CD Emergency Diesel Jacket Water Pump QT-130-CD1 Discharge Pressure Switch Diesel Jacket Water Auxiliary 587 CD EDG Room 122 1-CPS-319 CD Emergency Diesel Jacket Water Pump QT-130-CD2 Discharge Pressure Switch Diesel Jacket Water Auxiliary 587 CD EDG Room 122 1-DG-101C CD Emergency Diesel Starting Air Compressor QT-142-CD2 Outlet Check Valve Diesel Starting Air Auxiliary 587 CD EDG Room 122 1-DG-103C CD Emergency Diesel Starting Air Compressor QT-142-CD1 Outlet Check Valve Diesel Starting Air Auxiliary 587 CD EDG Room 122 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page:

9 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-DGCD CD Emergency Diesel Generator OME-150-CD Control Subpanel Diesel Generator, Control and Instrumentation Auxiliary 587 CD EDG Room 122 1-DGCD-FFCKT CD Emergency Diesel Generator OME-150-CD Field Flash CKT Transformer Diesel Generator, Control and Instrumentation Auxiliary 587 CD EDG Room 122 1-DGCD-INV CD Emergency Diesel Generator OME-150-CD Inverter Diesel Generator, Control and Instrumentation Auxiliary 587 CD EDG Room 122 1-DGCDX Equi p Ctrl and Indication Stn/Cd Emergency Diesel Generator 150 Aux Panel Diesel Generator, Control and Instrumentation Auxiliary 587 CD EDG Room 122 1-HE-47-CDN CD Emergency Diesel North Combustion Air Aftercooler Diesel Combustion Air Auxiliary 587 CD EDG Room 122 1-HE-47-CDS CD Emergency Diesel South Combustion Air Aftercooler Diesel Combustion Air Auxiliary 587 CD EDG Room 122 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page: 10 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-HE-55-CD Governor Oil Cooler For CD Emergency Diesel Engine Diesel Jacket Water Auxiliary 587 CD EDG Room 122 1-HV-DDP-CD1 CD Emergency Diesel Generator Room Ventilation Exhaust Fan HV-DGX-2 Tempering Air Damper Diesel Room Ventilation Auxiliary 587 CD EDG Room 122 1-HV-DDP-CD2 CD Emergency Diesel Generator Room Ventilation Supply Fan HV-DGS-2 Tempering Air Damper Diesel Room Ventilation Auxiliary 587 CD EDG Room 122 1-HV-DGS-1 AB Emergency Diesel Generator Room Ventilation Supply Fan Diesel Room Ventilation Auxiliary 587 CD EDG Room 122 1-HV-DGS-4 CD Emergency Diesel Generator Room Cabinet Ventilation Supply Fan Diesel Room Ventilation Auxiliary 587 CD EDG Room 122 1-HV-DGX-2 CD Emergency Diesel Generator Room Ventilation Exhaust Fan Diesel Room Ventilation Auxiliary 587 CD EDG Room 122 1-LLS-125 CD Emergency Diesel Fuel Oil Day Tank QT-107-CD High Level Switch #1 Diesel Fuel Oil Auxiliary 587 CD EDG Room 122 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page: 11 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-LLS-126 CD Emergency Diesel Fuel Oil Day Tank QT-107-CD Low Level Switch #1 Diesel Fuel Oil Auxiliary 587 CD EDG Room 122 1-LLS-127 CD Emergency Diesel Fuel Oil Day Tank QT-107-CD High Level Switch #2 Diesel Fuel Oil Auxiliary 587 CD EDG Room 122 1-LLS-128 CD Emergency Diesel Fuel Oil Day Tank QT-107-CD Low Level Switch #2 Diesel Fuel Oil Auxiliary 587 CD EDG Room 122 1-LRV-245 CD Emergency Diesel Upper Valve Gear Lube Oil Regulator #1 Diesel Lube Oil Auxiliary 587 CD EDG Room 122 1-LRV-246 CD Emergency Diesel Upper Valve Gear Lube Oil Regulator #2 Diesel Lube Oil Auxiliary 587 CD EDG Room 122 1-LSO-245 CD Emergency Diesel Gen Upper Valve Gear Lubrication Control Solenoid #1 Diesel Lube Oil Auxiliary 587 CD EDG Room 122 1-LSO-246 CD Emergency Diesel Gen Upper Valve Gear Lubrication Control Solenoid #2 Diesel Lube Oil Auxiliary 587 CD EDG Room 122 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page: 12 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-OME-150-CD CD Emergency Diesel Generator Diesel Generator, Control &

Instrumentation Auxiliary 587 CD EDG Room 122 1-POV-1-CD Starting Air Syst/Pilot Operated 4-Way Valve For Air Start of XRVS For Diesel Engine Compressed Air Auxiliary 587 CD EDG Room 122 1-POV-2-CD Starting Air Syst/Pilot Operated 4-Way Valve For Air Start of XRVS For Diesel Engine Compressed Air Auxiliary 587 CD EDG Room 122 1-PP-120-CD Engine Driven Pump Diesel Fuel Oil Auxiliary 587 CD EDG Room 122 1-PP-122-CD Engine Driven Lube Oil Pump Diesel Lube Oil Auxiliary 587 CD EDG Room 122 1-QT-101-CD CD Emergency Diesel Air Intake Silencer Diesel Combustion Air Auxiliary 587 CD EDG Room 122 1-QT-107-CD CD Emergency Diesel Fuel Oil Day Tank Diesel Fuel Oil Auxiliary 587 CD EDG Room 122 1-QT-110-CD CD Emergency Diesel Lube Oil Cooler Diesel Lube Oil Auxiliary 587 CD EDG Room 122 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page: 13 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-QT-114-CD CD Emergency Diesel Lube Oil Cooler QT-110-CD Lube Oil Thermostatic Inlet/Bypass Valve Diesel Lube Oil Auxiliary 587 CD EDG Room 122 1-QT-130-CD1 CD Emergency Diesel Jacket Water Pump #1 Diesel Jacket Water Auxiliary 587 CD EDG Room 122 1-QT-130-CD2 Cd Emergency Diesel Jacket Water Pump #2 Diesel Jacket Water Auxiliary 587 CD EDG Room 122 1-QT-131-CD CD Emergency Diesel Jacket Water Cooler Diesel Jacket Water Auxiliary 587 CD EDG Room 122 1-QT-132-CD CD Emergency Diesel Jacket Water Cooler QT-131-CD Thermostatic Inlet/Bypass Valve Diesel Jacket Water Auxiliary 587 CD EDG Room 122 1-QT-133-CD CD Emergency Diesel Jacket Water Surge Tank Diesel Jacket Water Auxiliary 587 CD EDG Room 122 1-QT-135-CD CD Emergency Diesel Auxiliary Jacket Water Pump Diesel Jacket Water Auxiliary 587 CD EDG Room 122 1-QT-141-CD1 CD Emergency Diesel Starting Air Receiver #1 Diesel Starting Air Auxiliary 587 CD EDG Room 122 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page: 14 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-QT-141-CD2 CD Emergency Diesel Starting Air Receiver #2 Diesel Starting Air Auxiliary 587 CD EDG Room 122 1-QT-143-CD1 CD Emergency Diesel Control Air Dryer #1 Diesel Control Air Auxiliary 587 CD EDG Room 122 1-QT-143-CD2 CD Emergency Diesel Control Air Dryer #2 Diesel Control Air Auxiliary 587 CD EDG Room 122 1-QT-144-CD CD Emergency Diesel Fuel Oil Transfer Filter Diesel Fuel Oil Auxiliary 587 CD EDG Room 122 1-QT-502-CD CD Emergency Diesel Turbocharger Diesel Combustion Air Auxiliary 587 CD EDG Room 122 1-SV-120-CD 1-XTC-306 and 1-XTC-307 Control Air Safety Valve Control Air Auxiliary 587 CD EDG Room 122 1-SV-139-CD CD Emergency Diesel Starting Air to Turbocharger Safety Valve Diesel Starting Air Auxiliary 587 CD EDG Room 122 1-SV-200-CD CD Emergency Diesel Fuel Oil Manifolds to Fuel Oil Day Tank Safety Valve Diesel Fuel Oil Auxiliary 587 CD EDG Room 122 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page: 15 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-SV-201-AB1 AB Emergency Diesel Front Bank Fuel Oil Manifold Safety Valve Diesel Fuel Oil Auxiliary 587 CD EDG Room 122 1-SV-201-CD1 CD Emergency Diesel Front Bank Fuel Oil Manifold Safety Valve Diesel Fuel Oil Auxiliary 587 CD EDG Room 122 1-SV-201-CD2 CD Emergency Diesel Rear Bank Fuel Oil Manifold Safety Valve Diesel Fuel Oil Auxiliary 587 CD EDG Room 122 1-SV-216-CD CD Engine Driven Lube Oil Pump PP-122-CD Integral Relief Valve Diesel Lube Oil Auxiliary 587 CD EDG Room 122 1-SV-61-CD CD Emergency Diesel Auxiliary Jacket Water Heater QT-134-CD Safety Valve Diesel Jacket Water Auxiliary 587 CD EDG Room 122 1-SV-78-CD1 CD Emergency Diesel Starting Air Receiver QT-141-CD1 Safety Valve Diesel Starting Air Auxiliary 587 CD EDG Room 122 1-SV-78-CD2 CD Emergency Diesel Starting Air Receiver QT-141-CD2 Safety Valve Diesel Starting Air Auxiliary 587 CD EDG Room 122 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page: 16 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-SV-79-CD1 CD Emergency Diesel Control Air Dryer QT-143-CD1 Safety Valve Diesel Starting Air Auxiliary 587 CD EDG Room 122 1-SV-79-CD2 CD Emergency Diesel Control Air Dryer QT-143-CD2 Safety Valve Diesel Starting Air Auxiliary 587 CD EDG Room 122 1-TR-AFW Auxiliary Feedwater 120/208VAC Distribution Panel AFW Supply Transformer 120/208VAC Misc Safety Related Power Distribution Auxiliary 587 CD EDG Room 122 1-VTS-346 CD Emergency Diesel Generator Room Ventilation Exhaust Fan HV-DGX-2 Thermostat Diesel Room Ventilation Auxiliary 587 CD EDG Room 122 1-WRV-725 CD Emergency Diesel South Combustion Air Aftercooler HE CDS ESW Inlet/Bypass Valve Essential Service Water Auxiliary 587 CD EDG Room 122 1-WRV-727 CD Emergency Diesel North Combustion Air Aftercooler HE CDN ESW Inlet/Bypass Valve Essential Service Water Auxiliary 587 CD EDG Room 122 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page: 17 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-XPS-305 Diesel Combustion Air/Cd Front Bank Air Chest Extreme High Pressure Switch Diesel Combustion Air Auxiliary 587 CD EDG Room 122 1-XRV-226 CD Emergency Diesel Front Bank Starting Air Shutoff Valve Diesel Starting Air Auxiliary 587 CD EDG Room 122 1-XRV-227 CD Emergency Diesel Rear Bank Starting Air Shutoff Valve Diesel Starting Air Auxiliary 587 CD EDG Room 122 1-XRV-228 CD Emergency Diesel Starting Air to Turbocharger Pressure Reducing Valve Diesel Starting Air Auxiliary 587 CD EDG Room 122 1-XRV-236 CD Emergency Diesel Starting Air to Control Air Dryer #1 Pressure Reducing Valve Diesel Starting Air Auxiliary 587 CD EDG Room 122 1-XRV-237 CD Emergency Diesel Starting Air to Control Air Dryer #2 Pressure Reducing Valve Diesel Starting Air Auxiliary 587 CD EDG Room 122 1-XRV-245 1-XTC-306 and 1-XTC-307 Control Air Pressure Reducing Valve (CD)

Diesel Control Air Auxiliary 587 CD EDG Room 122 QC-225-CD Duplex Engine Fuel Oil Filter Diesel Fuel Oil Auxiliary 587 CD EDG Room 122 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page: 18 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-ARA-2 Reactor Protection Train 'A' Auxiliary Relay Cabinet #2 120/220VAC Control and Instrumentation Auxiliary 633 Control Room 123 1-ARB-2 Reactor Protection Train 'B' Auxiliary Relay Cabinet #2 120/220VAC Control and Instrumentation Auxiliary 633 Control Room 123 1-CCV-AB 250VDC Train 'B' Critical Solenoid Valves Distribution Panel 250VDC Auxiliary 633 Control Room 123 1-CCV-CD 250VDC Train 'A' Critical Solenoid Valves Distribution Panel 250VDC Auxiliary 633 Control Room 123 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page: 19 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-CRAB 250VDC Control Room Distribution Panel CRAB 250VDC Auxiliary 633 Control Room 123 1-CRCD 250VDC Control Room Distribution Panel CRCD 250VDC Auxiliary 633 Control Room 123 1-CRID-I 120VAC Control Room Instrument Distribution Channel I Distribution Panel 120VAC Control Room Instrumentation Distr Auxiliary 633 Control Room 123 1-CRID-II 120VAC Control Room Instrument Distribution Channel II Distribution Panel 120VAC Control Room Instrumentation Distr Auxiliary 633 Control Room 123 1-CRID-III 120VAC Control Room Instrument Distribution Channel III Distribution Panel 120VAC Control Room Instrumentation Distr Auxiliary 633 Control Room 123 1-CRID-IV 120VAC Control Room Instrument Distribution Channel IV Distribution Panel 120VAC Control Room Instrumentation Distr Auxiliary 633 Control Room 123 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page: 20 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-CRID-IV-INV 120VAC Control Room Instrument Distribution System Channel Iv Inverter 120VAC Control Room Instrumentation Distr Auxiliary 633 Control Room 123 1-NIS-I Nuclear Instrumentation System Protection Channel I Control Panel Equi pment Control and Indication Stations Auxiliary 633 Control Room 123 1-NIS-III Nuclear Instrumentation System Protection Channel III Control Panel Equi pment Control and Indication Stations Auxiliary 633 Control Room 123 1-NRI-1 Nuclear Instrumentation Source Range Monitor Reactor Coolant Auxiliary 633 Control Room 123 1-NRI-21-PRCSR Nuclear Instrumentation Wide Range Signal Processor Cabinet Nuclear Instrumentation Auxiliary 633 Control Room 123 1-NRI-23-PRCSR Nuclear Instrumentation Source Range Signal Processor Cabinet Nuclear Instrumentation Auxiliary 633 Control Room 123 1-NRI-5 Nuclear Instrumentation Source Range Monitor Reactor Coolant Auxiliary 633 Control Room 123 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page: 21 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-PRZ Pressurizer Control Panel Reactor Coolant Auxiliary 633 Control Room 123 1-RC Reactor Control Rods Control Panel Rod Control and Instrumentation Auxiliary 633 Control Room 123 1-RHR Residual Heat Removal Control Panel Residual Heat Removal Auxiliary 633 Control Room 123 1-RPC-I Reactor Protection Channel I Cab #1, 2, 3 & 4 Reactor Protection Auxiliary 633 Control Room 123 1-RPC-II Reactor Protection Channel II Cabinet #5, 6, 7, & 8 Reactor Protection Auxiliary 633 Control Room 123 1-RPC-III Reactor Protection Channel III Cabinet #9, 10 & 11 Reactor Protection Auxiliary 633 Control Room 123 1-RPC-IV Reactor Protection Channel IV Cabinet #12 & 13 Reactor Protection Auxiliary 633 Control Room 123 1-RPS-A Reactor Protection and Safeguard Actuation Train 'A' Cabinet Reactor Protection Auxiliary 633 Control Room 123 1-RPS-B Reactor Protection and Safeguard Actuation Train 'B' Cabinet Reactor Protection Auxiliary 633 Control Room 123 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 4 of 6 Page: 22 of 22 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-RPSX-A Reactor Protection and Safeguard Actuation Train "A" Auxiliary Cabinet Reactor Protection Auxiliary 633 Control Room 123 1-RPSX-B Reactor Protection and Safeguard Actuation Train "B" Auxiliary Cabinet Reactor Protection Auxiliary 633 Control Room 123 1-SA Station Auxiliaries Control Panel 4160VAC Auxiliary 633 Control Room 123 1-SG Steam Generator and Auxiliary Feed Pump Control Panel Steam Generator Auxiliary 633 Control Room 123 1-VDAB-1 250VDC Valve Distribution Panel VDAB-1 250VDC Auxiliary 633 Control Room 123 1-VDAB-2 250VDC Valve Distribution Panel VDAB-2 250VDC Auxiliary 633 Control Room 123 1-VDCD-1 250VDC Valve Distribution Panel VDCD-1 250VDC Auxiliary 633 Control Room 123 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page:

1 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-QT-106-CD1 CD Emergency Diesel Fuel Oil Transfer Pump #1 Diesel Fuel Oil Auxiliary 587 CD EDG Fuel Oil Transfer Pump Room 125 1-QT-106-CD2 CD Emergency Diesel Fuel Oil Transfer Pump #2 Diesel Fuel Oil Auxiliary 587 CD EDG Fuel Oil Transfer Pump Room 125 1-QT-106-AB1 AB Emergency Diesel Fuel Oil Transfer Pump #1 Diesel Fuel Oil Auxiliary 587 AB EDG Fuel Oil Transfer Pump Room 126 1-QT-106-AB2 AB Emergency Diesel Fuel Oil Transfer Pump #2 Diesel Fuel Oil Auxiliary 587 AB EDG Fuel Oil Transfer Pump Room 126 1-HE-63N Control Room Air Conditioning North Liquid Chiller HV-ACR-1 Evaporator Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-HE-63S Control Room Air Conditioning South Liquid Chiller HV-ACR-2 Evaporator Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-HE-64N Control Room Air Conditioning North Liquid Chiller HV-ACR-1 Condenser Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page:

2 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-HE-64S Control Room Air Conditioning South Liquid Chiller HV-ACR-2 Condenser Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-HV-ACR-1 Control Room Air Conditioning System Liqui d Chiller Package (North)

Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-HV-ACR-2 Control Room Air Conditioning System Liqui d Chiller Package (South)

Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-HV-ACRA-1 Control Room Air Conditioning System Air Handling Package (North)

Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-HV-ACRA-2 Control Room Air Conditioning System Air Handling Package (South)

Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-HV-ACR-DA-1 Outside Air to Control Room Ventilation Units HV-ACRA-1 and HV-ACRA-2 Vent Damper Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-HV-ACR-DA-2 Control Room Ventilation Outside Air Intake Damper Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-HV-ACR-DA-3 Control Room Ventilation Return Air Damper Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-HV-ACRF-1 Control Room Pressurizer/Cleanup Filter Supply Fan (East)

Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page:

3 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-HV-ACRF-2 Control Room Pressurizer/Cleanup Filter Supply Fan (West)

Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-PP-82N Control Room Air Conditioning North Chill Water Circulation Pump Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-PP-82S Control Room Air Conditioning South Chill Water Circulation Pump Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-TK-76N Control Room Air Conditioning North Chill Water Expansion Tank Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-TK-76S Control Room Air Conditioning South Chill Water Expansion Tank Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-VRV-315 Control Room Ventilation Unit HV-ACRA-1 Chilled Water Inlet/Bypass Valve Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-VRV-325 Control Room Ventilation Unit HV-ACRA-2 Chilled Water Inlet/Bypass Valve Control Room Ventilation Auxiliary 650 Control Room A/C Room 129 1-WRV-711-1N ESW from CRAC N Lqd Chiller 1-HV-ACR-1 Cndsr Wtr Reg Vlv (CKT 1)

Essential Service Water Auxiliary 650 Control Room A/C Room 129 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page:

4 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-WRV-711-2N ESW from CRAC N Lqd Chiller 1-HV-ACR-1 Cndsr Wtr Reg Vlv (CKT 2)

Essential Service Water Auxiliary 650 Control Room A/C Room 129 1-WRV-712-1S ESW from CRAC S Lqd Chiller 1-HV-ACR-2 Cndsr Wtr Reg Vlv (Ckt 1)

Essential Service Water Auxiliary 650 Control Room A/C Room 129 1-WRV-712-2S ESW from CRAC S Lqd Chiller 1-HV-ACR-2 Cndsr Wtr Reg Vlv (Ckt 2)

Essential Service Water Auxiliary 650 Control Room A/C Room 129 1-XSO-315 Control Room Venitilation Unit HV-ACRA-1 Chilled Water Inlet/Bypass Valve VRV-315 Control Solenoid Control Air Auxiliary 650 Control Room A/C Room 129 1-XSO-325 Control Room Venitilation Unit HV-ACRA-2 Chilled Water Inlet/Bypass Valve VRV-325 Control Solenoid Control Air Auxiliary 650 Control Room A/C Room 129 1-WFA-701 East Essential Service Water Supply Header Flow Transmitter Essential Service Water Turbine 569 ESW Pipe Tunnel 131 1-WFA-705 West Essential Service Water Supply Header Flow Transmitter Essential Service Water Turbine 569 ESW Pipe Tunnel 131 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page:

5 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-WMO-705 West Essential Service Water Supply Header Crosstie to Unit 2 Motor Operated Shutoff Valve Essential Service Water Turbine 569 ESW Pipe Tunnel 131 1-WMO-707 East Essential Service Water Supply Header Crosstie to Unit 2 Motor Operated Shutoff Valve Essential Service Water Turbine 569 ESW Pipe Tunnel 131 1-WPI-705 West Essential Service Water Supply Header Pressure Indicator Transmitter Essential Service Water Turbine 569 ESW Pipe Tunnel 131 1-WPI-707 East Essential Service Water Supply Header Pressure Indicator Transmitter Essential Service Water Turbine 569 ESW Pipe Tunnel 131 1-WPS-701 East Essential Service Water Supply Header Pressure Switch Essential Service Water Turbine 569 ESW Pipe Tunnel 131 1-WPS-705 West Essential Service Water Supply Header Pressure Switch Essential Service Water Turbine 569 ESW Pipe Tunnel 131 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page:

6 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

12-HV-ESW-7 Unit 1 East Essential Service Water Pump Room Supply Ventilation Fan Esw Ventilation Screenhouse 591 East ESW Pump Room 135 12-HV-ESW-8 Unit 1 East Essential Service Water Pump Room Supply Ventilation Fan Esw Ventilation Screenhouse 591 East ESW Pump Room 135 1-OME-34E East Essential Service Water Pump PP-7E Duplex Strainer Essential Service Water Screenhouse 591 East ESW Pump Room 135 1-PP-7E East Essential Service Water Pump Essential Service Water Screenhouse 591 East ESW Pump Room 135 1-VTS-706 Unit 1 West Essential Service Water Pump Room Temperature Switch Esw Ventilation Screenhouse 591 East ESW Pump Room 135 1-WMO-701 East Essential Service Water Pump PP-7E Discharge Motor Operated Shutoff Valve Essential Service Water Screenhouse 591 East ESW Pump Room 135 12-HV-ESW-5 Unit 1 West Essential Service Water Pump Room Supply Ventilation Fan Esw Ventilation Screenhouse 591 West ESW Pump Room 136 12-HV-ESW-6 Unit 1 West Essential Service Water Pump Room Supply Ventilation Fan Esw Ventilation Screenhouse 591 West ESW Pump Room 136 1-OME-34W West Essential Service Water Pump PP-7W Duplex Strainer Essential Service Water Screenhouse 591 West ESW Pump Room 136 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page:

7 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-PP-7W West Essential Service Water Pump Essential Service Water Screenhouse 591 West ESW Pump Room 136 1-VTS-708 Unit 1 East Essential Service Water Pump Room Temperature Switch Esw Ventilation Screenhouse 591 West ESW Pump Room 136 1-WMO-702 West Essential Service Water Pump PP-7W Discharge Motor Operated Shutoff Valve Essential Service Water Screenhouse 591 West ESW Pump Room 136 1-HV-SGRS-2 4KV Room AB 4KV Switchgear Area Ventilation Supply Fan Elec. Swgr.

Ventilation Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-HV-SGRX-2 4KV Room AB 4KV Switchgear Area Ventilation Exhaust Fan Elec. Swgr.

Ventilation Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-T11A 4KV Bus T11A Switchgear 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-T11A1 South Safety Injection Pump PP-26S Supply Breaker 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page:

8 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-T11A10 Transformer TR11A to 600VAC Bus 11A Supply Breaker 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-T11A11 AB Emergency Diesel Generator to 4KV Bus T11A Supply Breaker 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-T11A12 Circuit Breaker From 69KV to Bus T11A 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-T11A2 West Motor Driven Aux Feedwater Pump PP-3W Supply Breaker 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-T11A4 West Residual Heat Removal Pump PP-35W Supply Breaker 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-T11A5 West Essential Service Water Pump PP-7W Supply Breaker 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page:

9 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-T11A7 West Component Cooling Water Pump PP-10W Supply Breaker 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-T11A8 West Centrifugal Charging Pump PP-50W Supply Breaker 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-T11A9 4KV Bus 1A to Bus T11A Tie Breaker 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-T11B 4KV Bus T11B Switchgear 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-T11B1 4KV Bus 1B to 4KV Bus T11B Tie Breaker 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-T11B2 Circuit Breaker From 69KV Bus to Bus T11B 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page: 10 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-T11B4 AB Emergency Diesel Generator to 4KV Bus T11B Supply Breaker 4160VAC Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-VTS-802 4KV Room AB 4KV Switchgear Area Ventilation Supply Fan HV-SGRS-2 Thermal Sensor Elec. Swgr.

Ventilation Auxiliary 609 4KV Room - AB 4KV Switchgear Area 140 1-WMO-721 West Essential Service Water Supply Header to AB Emergency Diesel Heat Exchangers Motor Operated Shutoff Valve Essential Service Water Auxiliary 587 AB EDG Room South Pipe Tunnel 170 1-WMO-723 East Essential Service Water Supply Header to AB Emergency Diesel Heat Exchangers Motor Operated Shutoff Valve Essential Service Water Auxiliary 587 AB EDG Room South Pipe Tunnel 170 1-WMO-725 East Essential Service Water Supply Header to CD Emergency Diesel Heat Exchangers Motor Operated Shutoff Valve Essential Service Water Auxiliary 587 AB EDG Room South Pipe Tunnel 170 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page: 11 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-WMO-727 West Essential Service Water Supply Header to CD Emergency Diesel Heat Exchangers Motor Operated Shutoff Valve Essential Service Water Auxiliary 587 AB EDG Room South Pipe Tunnel 170 1-BATT-AB Plant Battery AB 250VDC Auxiliary 609 AB Batt Equi p Area 200 1-HV-SGRX-5 AB Battery Equipment Area Battery Room Ventilation Exhaust Fan Elec. Swgr.

Ventilation Auxiliary 609 AB Batt Equi p Area 200 1-MCAB 250VDC Distribution Panel MCAB 250VDC Auxiliary 609 AB Batt Equi p Area 200 1-MDAB 250VDC Distribution Panel MDAB 250VDC Auxiliary 609 AB Batt Equi p Area 200 1-TDAB 250 VDC Train 'B' Transfer Cabinet 250VDC Auxiliary 609 AB Batt Equi p Area 200 1-BATT-CD Plant Battery CD 250VDC Auxiliary 626 CD Batt Equi p Area 201 1-BATT-CD-SH Plant Battery BATT-CD Ammeter Shunt Cabinet 250VDC Auxiliary 626 CD Batt Equi p Area 201 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page: 12 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-BC-CD1 Plant Battery BATT-CD Charger #1 250VDC Auxiliary 626 CD Batt Equi p Area 201 1-BC-CD2 Plant Battery BATT-CD Charger #2 250VDC Auxiliary 626 CD Batt Equi p Area 201 1-BC-CD-SH Plant Battery Charger Ammeter BC-CD Shunt Cabinet 250VDC Auxiliary 626 CD Batt Equi p Area 201 1-BCTC-CD Plant Battery Chargers BC-CD1 and BC-CD2 Transfer Switch Cabinet 250VDC Auxiliary 626 CD Batt Equi p Area 201 1-HV-SGRX-6 CD Battery Equipment Area Battery Room Ventilation Exhaust Fan Elec. Swgr.

Ventilation Auxiliary 626 CD Batt Equi p Area 201 1-MCCD 250VDC Distribution Panel MCCD 250VDC Auxiliary 626 CD Batt Equi p Area 201 1-MDCD 250VDC Distribution Panel MDCD 250VDC Auxiliary 626 CD Batt Equi p Area 201 1-TDCD 250 VDC Train 'A' Transfer Cabinet 250VDC Auxiliary 626 CD Batt Equi p Area 201 1-BATT-AB-SH Plant Battery Batt-AB Ammeter Shunt Cabinet 250VDC Auxiliary 609 Inverter Area 202 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page: 13 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-CRID-III-INV 120VAC Control Room Instrumentation Distribution System Channel III Inverter 120VAC Control Room Instrumentation Distr Auxiliary 609 Inverter Area 202 1-CRID-II-INV 120VAC Control Room Instrument Distribution System Channel II Inverter 120VAC Control Room Instrumentation Distr Auxiliary 609 Inverter Area 202 1-CRID-I-INV 120VAC Control Room Instrument Distribution System Channel I Inverter 120VAC Control Room Instrumentation Distr Auxiliary 609 Inverter Area 202 1-VTS-350 Control Rod Drive Equi p Room and Inv Area Vent North Supply Fan HV-SGRS-1A Temperature Switch Elec. Swgr.

Ventilation Auxiliary 609 Inverter Area 202 1-VTS-354 Ctrl Rod Drv Equi p Room and Inv Area Vent Outside Air Inlet Damper HV-SGR-MD-2 Temperature Switch Elec. Swgr.

Ventilation Auxiliary 609 Inverter Area 202 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page: 14 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-VTS-355 Ctrl Rod Drive Equi p Room and Inv Area Vent Recirc Air Inlet Damper HV-SGR-MD-1 Temperature Switch Elec. Swgr.

Ventilation Auxiliary 609 Inverter Area 202 1-VTS-356 Crd Equi pment Room and Inverter Area Ventilation North Supply Fan HV-SGRS-4A Temp Switch Elec. Swgr.

Ventilation Auxiliary 609 Inverter Area 202 1-52-BYA Reactor Rod Control Train 'A' Reactor Trip Bypass Circuit Breaker Rod Control and Instrumentation Auxiliary 609 Control Rod Drive Equi pment Room 203 1-52-BYB Reactor Rod Control Train 'B' Reactor Trip Bypass Circuit Breaker Rod Control and Instrumentation Auxiliary 609 Control Rod Drive Equi pment Room 203 1-52-RTA Reactor Rod Control Train 'A' Reactor Trip Circuit Breaker Rod Control and Instrumentation Auxiliary 609 Control Rod Drive Equi pment Room 203 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page: 15 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-52-RTB Reactor Rod Control Train 'B' Reactor Trip Circuit Breaker Rod Control and Instrumentation Auxiliary 609 Control Rod Drive Equi pment Room 203 1-VTS-351 Control Rod Drive Equi p Room and Inv Area Vent North Supply Fan HV-SGRS-1A Temperature Switch Elec. Swgr.

Ventilation Auxiliary 609 Control Rod Drive Equi pment Room 203 1-VTS-357 Ctrl Rod Drive Equi p Room and Inv Area Ventilation South Supply Fan HV-SGRS-4A Temperature Switch Elec. Swgr.

Ventilation Auxiliary 609 Control Rod Drive Equi pment Room 203 1-11A 600VAC BUS 11A Switchgear 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11A11 600VAC BUS 11A Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page: 16 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-11A2 600VAC MCC AM-A Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11A3 600VAC MCC EZC-A Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11A5 600VAC MCC ABD-A Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11A6 600VAC MCCS AB-A, PS-A, TPP-A, and VCCS ABV-A, AZV-A Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11B 600VAC BUS 11B Switchgear 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11B1 600VAC MCC ABD-B and 1-ELSC Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page: 17 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-11B11 600VAC BUS 11B Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11B2 600VAC MCC EZC-B Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11B4 600VAC MCC 1-AZ-BC Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11C 600VAC BUS 11C Switchgear 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11C1 600V BUS 11C Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11C10 600VAC MCC ABD-C and 1-AFW Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page: 18 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-11C6 600VAC MCC EZC-C Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11D 600VAC BUS 11D Switchgear 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11D1 600V BUS 11D Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11D14 600VAC MCC 1-AB-D, VCC 1-ABV-D, MCC 1-PS-D Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11D5 600VAC MCC ABD-D Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-11D6 600VAC MCC EZC-D Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page: 19 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-11D8 600VAC MCC AM-D Supply Breaker 600VAC Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-CRID-I-CVT 120VAC Control Room Instrument Distribution Channel I Constant Voltage Transformer 120VAC Control Room Instrumentation Distr Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-CRID-II-CVT 120VAC Control Room Instrument Distribution Channel II Constant Voltage Transformer 120VAC Control Room Instrumentation Distr Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-CRID-III-CVT 120VAC Control Room Instrument Distribution Channel III Constant Voltage Transformer 120VAC Control Room Instrumentation Distr Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-CRID-IV-CVT 120VAC Control Room Instrument Distribution Channel IV Constant Voltage Transformer 120VAC Control Room Instrumentation Distr Auxiliary 609 4KV Room -

600V Switchgear Area 204 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page: 20 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-HV-SGR-MD-1 Control Rod Drive Equi pment Room and Inverter Area Ventilation Recirculating Air Inlet Damper Elec. Swgr.

Ventilation Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-HV-SGR-MD-2 Control Rod Drive Equi pment Room and Inverter Area Ventilation Outside Air Inlet Damper Elec. Swgr.

Ventilation Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-HV-SGR-MD-3 4KV ROOM 600V Switchgear Transformers TR11A & TR11C Area Ventilation Supply Fan HV-SGRS-8 Suction Damper Elec. Swgr.

Ventilation Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-HV-SGR-MD-4 4KV ROOM 600V Switchgear Transformers TR11B & TR11D Area Ventilation Supply Fan HV-SGRS-7 Suction Damper Elec. Swgr.

Ventilation Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-HV-SGRS-1A Control Rod Drive Equi pment Room and Inverter Area Ventilation North Supply Fan Elec. Swgr.

Ventilation Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-HV-SGRS-4A Control Rod Drive Equi pment Room and Inverter Area Ventilation South Supply Fan Elec. Swgr.

Ventilation Auxiliary 609 4KV Room -

600V Switchgear Area 204 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page: 21 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-HV-SGRS-7 4KV ROOM 600 Volt Switchgear Transformers TR11B and TR11D Area Ventilation Supply Fan Elec. Swgr.

Ventilation Auxiliary 609 4KV Room -

600V Switchgear Area 204 1-HV-SGRS-8 4KV ROOM 600 Volt Switchgear Transformers TR11A and TR11C Area Ventilation Supply Fan Elec. Swgr.

Ventilation Auxiliary 609 4KV Room -

600v Switchgear Area 204 1-TR11A 600V BUS 11A Supply Transformer 600VAC Auxiliary 609 4KV Room -

600v Switchgear Area 204 1-TR11B 600V BUS 11B Supply Transformer 600VAC Auxiliary 609 4KV Room -

600v Switchgear Area 204 1-TR11C 600V BUS 11C Supply Transformer 600VAC Auxiliary 609 4KV Room -

600v Switchgear Area 204 1-TR11D 600V BUS 11D Supply Transformer 600VAC Auxiliary 609 4KV Room -

600v Switchgear Area 204 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page: 22 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-VTS-352 4KV ROOM 600 Volt Switchgear Xfrms TR11B and TR11D Area Vent Supply Fan HV-SGRS-7 Temperature Switch Elec. Swgr.

Ventilation Auxiliary 609 4KV Room -

600v Switchgear Area 204 1-VTS-808 4KV ROOM 600V Swgr Xfmrs TR11A and Tr11c Area Vent Supply Fan HV-SGRS-8 Temp Switch Temp Switch Elec. Swgr.

Ventilation Auxiliary 609 4KV Room -

600v Switchgear Area 204 1-BC-AB1 Plant Battery Batt-AB Battery Charger #1 250VDC Auxiliary 613 4KV Room -

Mezzanine Area 205 1-BC-AB2 Plant Battery Batt-AB Battery Charger #2 250VDC Auxiliary 613 4KV Room -

Mezzanine Area 205 1-BC-AB-SH Plant Battery Charger Ammeter BC-AB Shunt Cabinet 250VDC Auxiliary 613 4KV Room -

Mezzanine Area 205 1-BCTC-AB Plant Battery Chargers BC-AB1 and BC-AB2 250VDC Auxiliary 613 4KV Room -

Mezzanine Area 205 1-EZC-A 600VAC Motor Control Center EZC-A 600VAC Auxiliary 613 4KV Room -

Mezzanine Area 205 1-EZC-B 600VAC Motor Control Center EZC-B 600VAC Auxiliary 613 4KV Room -

Mezzanine Area 205 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 5 of 6 Page: 23 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-EZC-C 600VAC Motor Control Center EZC-C 600VAC Auxiliary 613 4KV Room -

Mezzanine Area 205 1-EZC-D 600VAC Motor Control Center EZC-D 600VAC Auxiliary 613 4KV Room -

Mezzanine Area 205 1-HV-SGR-MD-5 600VAC Motor Control Center Mezzanine Area VENTILATION Supply Fan HV-SGRS-9 Vent Damper Elec. Swgr.

Ventilation Auxiliary 613 4KV Room -

Mezzanine Area 205 1-HV-SGRS-9 600VAC Motor Control Center Mezzanine Area Ventilation Supply Fan Elec. Swgr.

Ventilation Auxiliary 613 4KV Room -

Mezzanine Area 205 1-VTS-353 600VAC Motor Control Center Mezzanine Area Vent Supply Fan HV-SGRS-9 Temperature Switch Elec. Swgr.

Ventilation Auxiliary 613 4KV Room -

Mezzanine Area 205 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page:

1 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-VTS-805 4KV Room 600V Swgr Xfmrs TR11B and TR11D HV-SGRS-7 Temp Switch Thermal Sensor Elec. Swgr.

Ventilation Auxiliary 613 4KV Room -

Mezzanine Area 205 1-HV-SGRS-3 4KV Room CD 4KV Switchgear Area Ventilation Supply Fan Elec. Swgr.

Ventilation Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-HV-SGRX-3 4KV Room CD 4KV Switchgear Area Ventilation Exhaust Fan Elec. Swgr.

Ventilation Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-T11C 4KV BUS T11C Switchgear 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-T11C1 4KV BUS 1C to 4KV BUS T11C Tie Breaker 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-T11C2 Circuit Breaker - 4KV FROM 69KV to BUS T11C 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page:

2 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-T11C3 CD Emergency Diesel Generator to 4KV BUS T11C Supply Breaker 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-T11D 4KV BUS T11D Switchgear 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-T11D1 4KV Emergency Power BUS EP to 4KV BUS T11D Supply Breaker 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-T11D10 East Essential Service Water Pump PP-7E Supply Breaker 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-T11D11 East Motor Driven Auxiliary Feedwater Pump PP-3E Supply Breaker 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-T11D12 4KV BUS 1D to 4KV BUS T11D Tie Breaker 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page:

3 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-T11D2 Transformer TR11D to 600VAC BUS 11D Supply Breaker 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-T11D3 East Component Cooling Water Pump PP-10E Supply Breaker 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-T11D5 North Safety Injection Pump PP-26N Supply Breaker 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-T11D6 East RHR Pump PP-35E Supply Breaker 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-T11D7 East Centrifugal Charging Pump PP-50E Supply Breaker 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-T11D8 CD Emergency Diesel Generator to 4KV BUS T11D Supply Breaker 4160VAC Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page:

4 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-VTS-803 4KV Room CD 4KV Switchgear Area Ventilation Supply Fan HV-SGRS-3 THERMAL SENSOR Elec. Swgr.

Ventilation Auxiliary 609 4KV Room - CD 4KV Switchgear Area 206 1-PS-A 600VAC Motor Control Center PS-A 600VAC Screenhouse 594 Traveling Screen MCC Upper Room 221 1-PS-D 600VAC Motor Control Center PS-D 600VAC Screenhouse 594 Traveling Screen MCC Upper Room 221 12-TK-47-AB AB Diesel Fuel Oil Storage Tank Diesel Fuel Oil Grounds 609 Inner Plant Grounds 244 12-TK-47-CD CD Diesel Fuel Oil Storage Tank Diesel Fuel Oil Grounds 609 Inner Plant Grounds 244 1-HV-DGS-DCD CD Emergency Diesel Generator Room Ventilation Supply Fan HV-DGS-2 Outside Air Shutoff Damper Diesel Room Ventilation Auxiliary 609 Inner Plant Grounds 244 1-QT-100-AB AB Emergency Diesel Air Intake Filter Diesel Combustion Air Grounds 609 Inner Plant Grounds 244 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page:

5 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-QT-100-CD CD Emergency Diesel Air Intake Filter Diesel Combustion Air Grounds 609 Inner Plant Grounds 244 1-QT-104-AB AB Emergency Diesel Exhaust Silencer Diesel Combustion Air Grounds 609 Inner Plant Grounds 244 1-QT-104-CD CD Emergency Diesel Exhaust Silencer Diesel Combustion Air Grounds 609 Inner Plant Grounds 244 1-QT-111-AB AB Emergency Diesel Lube Oil Before and After Pump Diesel Lube Oil Auxiliary 579 AB EDG Lube Oil Pit 257 1-QT-112-AB AB Emergency Diesel Full Flow Lube Oil Filter Diesel Lube Oil Auxiliary 579 AB EDG Lube Oil Pit 257 1-QT-113-AB1 AB Emergency Diesel Full Flow Lube Oil Strainer #1 Diesel Lube Oil Auxiliary 579 AB EDG Lube Oil Pit 257 1-QT-113-AB2 AB Emergency Diesel Full Flow Lube Oil Strainer #2 Diesel Lube Oil Auxiliary 579 AB EDG Lube Oil Pit 257 1-QT-115-AB AB Emergency Diesel Lube Oil Sump Tank Diesel Lube Oil Auxiliary 579 AB EDG Lube Oil Pit 257 1-QT-116-AB AB Emergency Diesel Lube Oil Heater Tank Diesel Lube Oil Auxiliary 579 AB EDG Lube Oil Pit 257 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page:

6 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-QT-117-AB AB Emergency Diesel Lube Oil Heater QT-116-AB Pump Diesel Lube Oil Auxiliary 579 AB EDG Lube Oil Pit 257 1-QT-118-AB AB Emergency Diesel Bypass Lube Oil Filter Diesel Lube Oil Auxiliary 579 AB EDG Lube Oil Pit 257 1-QT-119-AB AB Emergency Diesel Bypass Lube Oil Filter QT-118-AB Pump Diesel Lube Oil Auxiliary 579 AB EDG Lube Oil Pit 257 1-QT-111-CD CD Emergency Diesel Lube Oil Before and After Pump Diesel Lube Oil Auxiliary 579 CD EDG Lube Oil Pit 258 1-QT-112-CD CD Emergency Diesel Full Flow Lube Oil Filter Diesel Lube Oil Auxiliary 579 CD EDG Lube Oil Pit 258 1-QT-113-CD1 CD Emergency Diesel Full Flow Lube Oil Strainer #1 Diesel Lube Oil Auxiliary 587 CD EDG Lube Oil Pit 258 1-QT-113-CD2 CD Emergency Diesel Full Flow Lube Oil Strainer #2 Diesel Lube Oil Auxiliary 579 CD EDG Lube Oil Pit 258 1-QT-115-CD CD Emergency Diesel Lube Oil Sump Tank Diesel Lube Oil Auxiliary 579 CD EDG Lube Oil Pit 258 1-QT-116-CD CD Emergency Diesel Lube Oil Heater Tank Diesel Lube Oil Auxiliary 579 CD EDG Lube Oil Pit 258 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page:

7 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-QT-117-CD CD Emergency Diesel Lube Oil Heater QT-116-CD Pump Diesel Lube Oil Auxiliary 579 CD EDG Lube Oil Pit 258 1-QT-118-CD CD Emergency Diesel Bypass Lube Oil Filter Diesel Lube Oil Auxiliary 579 CD EDG Lube Oil Pit 258 1-QT-119-CD CD Emergency Diesel Bypass Lube Oil Filter QT-118-CD Pump Diesel Lube Oil Auxiliary 579 CD EDG Lube Oil Pit 258 1-HV-AFP-BRE-1 Train 'N' Battery Room East Exhaust Fan Afw Battery Rm Ventilation Auxiliary 633 Plant Battery Train 'N' Auxiliary Equi pment Room 263 1-HV-AFP-BRE-2 Train 'N' Battery Room West Exhaust Fan Afw Battery Rm Ventilation Auxiliary 633 Plant Battery Train 'N' Auxiliary Equi pment Room 263 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page:

8 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-FMO-211 Turbine Driven Auxiliary Feed Pump PP-4 Discharge to Steam Generator OME-3-1 Motor Operated Control Valve Auxiliary Feedwater Auxiliary 612 East Non-Essential Service Water Valve Gallery 289 1-FMO-241 Turbine Driven Auxiliary Feed Pump PP-4 Supply to Steam Generator OME-3-4 Motor Operated Control Valve Auxiliary Feedwater Auxiliary 612 East Non-Essential Service Water Valve Gallery 289 1-FMO-242 West Motor Driven Auxiliary Feedwater Pump PP-3W Supply to Steam Generator OME-3-4 Motor Operated Control Valve Auxiliary Feedwater Auxiliary 612 East Non-Essential Service Water Valve Gallery 289 1-XSO-211 Steam Generator #1 Stop Valve MRV-210 Steam Cylinder Train 'A' Dump Valve MRV-211 Control Solenoid Control Air Auxiliary 612 East Non-Essential Service Water Valve Gallery 289 1-XSO-212 Steam Generator #1 Stop Valve MRV-210 Steam Cylinder Train 'B' Dump Valve MRV-212 Control Solenoid Control Air Auxiliary 612 East Non-Essential Service Water Valve Gallery 289 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page:

9 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-XSO-241 Steam Generator #4 Stop Valve MRV-240 Steam Cylinder Train 'A' Dump Valve MRV-241 Control Solenoid Control Air Auxiliary 612 East Non-Essential Service Water Valve Gallery 289 1-XSO-242 Steam Generator #4 Stop Valve MRV-240 Steam Cylinder Train 'B' Dump Valve MRV-242 Control Solenoid Control Air Auxiliary 612 East Non-Essential Service Water Valve Gallery 289 1-IFC-315 East Residual Heat Removal Pump PP-35E Discharge Flow Switch Residual Heat Removal Auxiliary 573 573 Hallway 573 1-IFC-325 West Residual Heat Removal Pump PP-35W Discharge Flow Switch Residual Heat Removal Auxiliary 573 573 Hallway 573 1-AB-A 600VAC Motor Control Center AB-A 600VAC Auxiliary 587 587 Hallway 587 1-AB-D 600VAC Motor Control Center AB-D 600VAC Auxiliary 587 587 Hallway 587 1-AB-N 250VDC Valve Control Center AB-N 250VDC Distribution Auxiliary 587 587 Hallway 587 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page: 10 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-ABV-A 600VAC Valve Control Center ABV-A 600VAC Auxiliary 587 587 Hallway 587 1-ABV-D 600VAC Valve Control Center ABV-D 600VAC Auxiliary 587 587 Hallway 587 1-EPT-251 CVCS Centrifugal Pumps Discharge Flow Control Valve QRV-251 Electro-Pneumatic Transducer Control Air Auxiliary 587 587 Hallway 587 1-QFA-210 RCP Seal Water Injection to Reactor Coolant Pump PP-45-1 Low Flow Alarm Transmitter Reactor Coolant Pump Seal Water Inj/Leakoff Auxiliary 587 587 Hallway 587 1-QFA-220 RCP Seal Water Injection to Reactor Coolant Pump PP-45-2 Low Flow Alarm Transmitter Reactor Coolant Pump Seal Water Inj/Leakoff Auxiliary 587 587 Hallway 587 1-QFA-230 RCP Seal Water Injection to Reactor Coolant Pump PP-45-3 Low Flow Alarm Transmitter Reactor Coolant Pump Seal Water Inj/Leakoff Auxiliary 587 587 Hallway 587 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page: 11 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-QFA-240 RCP Seal Water Injection to Reactor Coolant Pump PP-45-4 Low Flow Alarm Transmitter Reactor Coolant Pump Seal Water Inj/Leakoff Auxiliary 587 587 Hallway 587 1-QFI-200 CVCS Charging Pumps Discharge Flow Indicator Transmitter CVCS (Charging)

Auxiliary 587 587 Hallway 587 1-AZ-BC 600VAC Motor Control Center AZ-BC 600VAC Auxiliary 609 609 Hallway 609 1-AZV-A 600VAC Valve Control Center AZV-A 600VAC Auxiliary 609 609 Hallway 609 1-CMO-410 East CCW Heat Exchanger HE-15E CCW Outlet Motor Operated Shutoff Valve Component Cooling Water Auxiliary 609 609 Hallway 609 1-CMO-411 CCW Pumps Suction Crosstie Train 'A' Motor Operated Shutoff Valve Component Cooling Water Auxiliary 609 609 Hallway 609 1-CMO-412 CCW Pumps Discharge Crosstie Train 'A' Motor Operated Shutoff Valve Component Cooling Water Auxiliary 609 609 Hallway 609 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page: 12 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-CMO-413 CCW Pumps Suction Crosstie Train 'B' Motor Operated Shutoff Valve Component Cooling Water Auxiliary 609 609 Hallway 609 1-CMO-414 CCW Pumps Discharge Crosstie Train 'B' Motor Operated Shutoff Valve Component Cooling Water Auxiliary 609 609 Hallway 609 1-CMO-415 CCW to Miscellaneous Service Train 'A' Motor Operated Shutoff Valve Component Cooling Water Auxiliary 609 609 Hallway 609 1-CMO-416 CCW to Miscellaneous Service Train 'B' Motor Operated Shutoff Valve Component Cooling Water Auxiliary 609 609 Hallway 609 1-CMO-419 East RHR Heat Exchanger HE-17E CCW Outlet Motor Operated Shutoff Valve Component Cooling Water Auxiliary 609 609 Hallway 609 1-CMO-420 West CCW Heat Exchanger CCW Outlet Motor Operated Shutoff Valve Component Cooling Water Auxiliary 609 609 Hallway 609 1-CPS-410 East Component Cooling Water Pump PP-10E Discharge Pressure Switch Component Cooling Water Auxiliary 609 609 Hallway 609 1-CPS-420 West Component Cooling Water Pump PP-10W Discharge Pressure Switch Component Cooling Water Auxiliary 609 609 Hallway 609 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page: 13 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-CTR-415 East Component Cooling Water Heat Exchanger HE-15E CCW Outlet Temperature Recorder Thermal Sensor Component Cooling Water Auxiliary 609 609 Hallway 609 1-CTR-425 West Component Cooling Water Heat Exchanger HE-15W CCW Outlet Temperature Recorder Thermal Sensor Component Cooling Water Auxiliary 609 609 Hallway 609 1-EPT-310 East RHR Heat Exchanger Flow Control Valve IRV-310 Electro-Pneumatic Transducer Control Air Auxiliary 609 609 Hallway 609 1-EPT-311 RHR Heat Exchangers Bypass Flow Control Valve IRV-311 Electro-Pneumatic Transducer Control Air Auxiliary 609 609 Hallway 609 1-EPT-320 West Rhr Heat Exchanger Flow Control Valve IRV-320 Electro-Pneumatic Transducer Control Air Auxiliary 609 609 Hallway 609 1-HE-15E East CCW Heat Exchanger Component Cooling Water Auxiliary 609 609 Hallway 609 1-HE-15W West CCW Heat Exchanger Component Cooling Water Auxiliary 609 609 Hallway 609 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page: 14 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-IFI-310 East Residual Heat Removal Heat Exchanger HE-17E Outlet Low Range Flow Indicator Transmitter Residual Heat Removal Auxiliary 609 609 Hallway 609 1-IFI-311 East Residual Heat Removal Heat Exchanger HE-17E Outlet High Range Flow Indicator Transmitter Residual Heat Removal Auxiliary 609 609 Hallway 609 1-IFI-320 West Residual Heat Removal Heat Exchanger HE-17W Outlet Low Range Flow Indicator Transmitter Residual Heat Removal Auxiliary 609 609 Hallway 609 1-IFI-321 West Residual Heat Removal Heat Exchanger HE-17W Outlet High Range Flow Indicator Transmitter Residual Heat Removal Auxiliary 609 609 Hallway 609 1-PP-10E East CCW Pump Component Cooling Water Auxiliary 609 609 Hallway 609 1-PP-10W West CCW Pump Component Cooling Water Auxiliary 609 609 Hallway 609 1-WMO-731 East Component Cooling Water Heat Exchanger HE-15E Essential Service Water Inlet Motor Operated Shutoff Valve Essential Service Water Auxiliary 609 609 Hallway 609 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page: 15 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-WMO-733 East Component Cooling Water Heat Exchanger HE-15E Essential Service Water Outlet Motor Operated Shutoff Valve Essential Service Water Auxiliary 609 609 Hallway 609 1-WMO-735 West Component Cooling Water Heat Exchanger Essential Service Water Inlet Motor Operated Shutoff Valve Essential Service Water Auxiliary 609 609 Hallway 609 1-WMO-737 West Component Cooling Water Heat Exchanger Essential Service Water Outlet Motor Operated Shutoff Valve Essential Service Water Auxiliary 609 609 Hallway 609 12-HV-ACCP-1 CCW Pump Ventilation North Supply Fan Auxiliary Building Ventilation Auxiliary 633 633 Hallway 633 12-HV-ACCP-2 CCW Pump Ventilation Middle Supply Fan Auxiliary Building Ventilation Auxiliary 633 633 Hallway 633 12-HV-ACCP-3 CCW Pump Ventilation South Supply Fan Auxiliary Building Ventilation Auxiliary 633 633 Hallway 633 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page: 16 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-AM-A 600VAC Motor Control Center AM-A 600VAC Auxiliary 633 633 Hallway 633 1-AM-D 600VAC Motor Control Center AM-D 600VAC Auxiliary 633 633 Hallway 633 1-BATT-N Train 'N' Plant Battery 250VDC Auxiliary 633 633 Hallway 633 1-BATT-N-SH Train 'N' Plant Battery Ammeter Shunt Cabinet 250VDC Auxiliary 633 633 Hallway 633 1-BC-A Train 'N' Battery Distribution Train 'A' Battery Charger 250VDC Auxiliary 633 633 Hallway 633 1-BC-B Train 'N' Battery Distribution Train 'B' Battery Charger 250VDC Auxiliary 633 633 Hallway 633 1-CAS Containment Auxiliaries Subpanel (Ventilation)

Containment Ventilation Auxiliary 633 633 Hallway 633 1-CMO-429 West Rhr Heat Exchanger HE-17W CCW Outlet Motor Operated Shutoff Valve Component Cooling Water Auxiliary 633 633 Hallway 633 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page: 17 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-DCN Train 'N' Battery Distribution Panel 250VDC Auxiliary 633 633 Hallway 633 1-WMO-711 East CS HX HE-18E ESW Inlet Motor Operated Shutoff Valve Essential Service Water Auxiliary 633 633 Hallway 633 1-WMO-715 West CS HX HE-18W ESW Inlet Motor Operated Shutoff Valve Essential Service Water Auxiliary 633 633 Hallway 633 1-TK-37 Component Cooling Water Surge Tank Component Cooling Water Auxiliary 650 650 Hallway 650 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page: 18 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-NTP-110A Reactor Coolant Loop #1 Hot Leg Channel I Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #1 60 1-NTP-110B Reactor Coolant Loop #1 Hot Leg Channel I Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #1 60 1-NTP-111A Reactor Coolant Loop #1 Hot Leg Channel I Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #1 60 1-NTP-111B Reactor Coolant Loop #1 Hot Leg Channel I Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #1 60 1-NTP-112A Reactor Coolant Loop #1 Hot Leg Channel I Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #1 60 1-NTP-112B Reactor Coolant Loop #1 Hot Leg Channel I Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #1 60 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page: 19 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-NTP-120A Reactor Coolant Loop #2 Hot Leg Channel II Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #2 61 1-NTP-120B Reactor Coolant Loop #2 Hot Leg Channel II Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #2 61 1-NTP-121A Reactor Coolant Loop #2 Hot Leg Channel II Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #2 61 1-NTP-121B Reactor Coolant Loop #2 Hot Leg Channel II Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #2 61 1-NTP-122A Reactor Coolant Loop #2 Hot Leg Channel II Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #2 61 1-NTP-122B Reactor Coolant Loop #2 Hot Leg Channel II Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #2 61 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page: 20 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-NTP-130A Reactor Coolant Loop #3 Hot Leg Channel III Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #3 62 1-NTP-130B Reactor Coolant Loop #3 Hot Leg Channel III Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #3 62 1-NTP-131A Reactor Coolant Loop #3 Hot Leg Channel III Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #3 62 1-NTP-131B Reactor Coolant Loop #3 Hot Leg Channel III Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #3 62 1-NTP-132A Reactor Coolant Loop #3 Hot Leg Channel III Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #3 62 1-NTP-132B Reactor Coolant Loop #3 Hot Leg Channel III Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #3 62 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page: 21 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-NTP-140A Reactor Coolant Loop #4 Hot Leg Channel IV Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #4 63 1-NTP-140B Reactor Coolant Loop #4 Hot Leg Channel IV Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #4 63 1-NTP-141A Reactor Coolant Loop #4 Hot Leg Channel IV Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #4 63 1-NTP-141B Reactor Coolant Loop #4 Hot Leg Channel IV Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #4 63 1-NTP-142A Reactor Coolant Loop #4 Hot Leg Channel IV Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #4 63 1-NTP-142B Reactor Coolant Loop #4 Hot Leg Channel IV Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 598 Lower Containment, Quadrant #4 63 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page: 22 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-NTP-210A Reactor Coolant Loop #1 Cold Leg Channel I Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 625 Lower Containment, Quadrant #1 60 1-NTP-210B Reactor Coolant Loop #1 Cold Leg Channel I Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 625 Lower Containment, Quadrant #1 60 1-NTP-220A Reactor Coolant Loop #2 Cold Leg Channel II Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 617 Lower Containment, Quadrant #2 61 1-NTP-220B Reactor Coolant Loop #2 Cold Leg Channel II Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 617 Lower Containment, Quadrant #2 61 1-NTP-230A Reactor Coolant Loop #3 Cold Leg Channel III Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 617 Lower Containment, Quadrant #3 62 1-NTP-230B Reactor Coolant Loop #3 Cold Leg Channel III Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 617 Lower Containment, Quadrant #3 62 UFSAR Revision 30.0

INDIANA MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revised: 27.0 Table:14.4.2-1A Part 6 of 6 Page: 23 of 23 Unit 1 Equipment Required to Shutdown Reactor (Unit 1)

(for High Energy Pipe Ruptures Outside the Containment)

Equipment ID Equipment Description System Building Elev Room Rm #

1-NTP-240A Reactor Coolant Loop #4 Cold Leg Channel IV Reactor Protection Input Spare Narrow Range Thermal Sensor Reactor Coolant Containment 625 Lower Containment, Quadrant #4 63 1-NTP-240B Reactor Coolant Loop #4 Cold Leg Channel IV Reactor Protection Input Narrow Range Thermal Sensor Reactor Coolant Containment 625 Lower Containment, Quadrant #4 63 UFSAR Revision 30.0