FSAR FIG. 1 - 1 STANDARD SYMBOLS Revised per UCR-70 17 PROCESS ACTUATED (EXTERNAL TAP) 17 I

I I

I F

I G

I H

I J

I K

I L

I M

I N

I 0

A I

B C

D E

~;. *rn:1 1:1vs:1 *oN *91,10 I INSTRUMENTATION AND S~MPLING FIRST LETTER V~L\\/E!I e

SA.MPL~

IDENTIFICATION LIST

&J TR~NSMITT!D t><l ti"TE SAF'ETY 1

1 A

AUXILIARY STE~M AND FEED PUMP TURBINE STEAM

~

e C8:J GLOBE.

AH&L~

STE~M GENERATOR.

LOGIII..L. 5,ii.MPL.E.

C CONDENSATE 1'NI) COOLING WATER

~

NO"-MALLY CLOSED Kl CHE'CK LOGALLV R&.MOTE D

DRIPS* l)~AINc; AND WA'tt-illNG STEAM

[)t::3 tel STo, C~ICK BUTTERFLY 2

2 MOUNTED MOUNTEO E

ENVIRONMENTAL MOHITO"IKG

+

e E3 F'

F'EEDWATE'R

~

THlllEE W1(

FLOAT CMI.C.K NON -T~,-..MSMITTIMtit G

GAS SYSTE.MS (e.'l<Cl'9T F'l,-_I. FIGHTING CO2,)

~

Dl~PHRli.titM Cfl NEEOl.E

~

H HEATE" 8L££DS AND DR.AIMS 8

B TR~NSMITTINEii TO M~LN CONTROL ROOM SAF'lTY 1NllC.TION1 RESIDUAL HEAT "EMO'IM. t CONTAINMtNT SPRAY VALVE OPER~TOR.S 3

3 J

k CONDl!... S,-TE ~NC CHC.MlCAL SER~ICES

~

AIR

~ COCK e

B L

L.U&~ OIL. ANO ELEC.'TR.O*HYDR~ULIC CONTROL. FI.UID I-TRANSMITTING. TO sue,-P~NEL

~.:: SOLE.NOID

,;., AIR PISTON M

MAIN STEAM

~

ELEC1"RIC MOTOR @_

N NUCLEAR REACTOR. COOLANT 6'.NO IN-Co~E INSTRUMENT$

1-.,l.OC.~LLV MOUNTED"' INSTRUMENT: ON.... PIPE, C.OLUMN, OR 0

IN"!>TRUMENT ~T~ND IN C.LOSE PROXIMITY TO SENSIN~ POINT.

~

p PLANT AIR MISC. SYMBOLS

~-.,REMOT& PA.NE~ MOUNTl:D.,\\tiSTP,UMEl'-lT: SIEiiNM. I\\L>N OIR£C.TL'<

~

CHEMICAL ~NO 'IOLUME. CONTROL FROM S.EMSlNEii POINT TO M...,IN CONTROL PP\\NE\\.. OP. SUB-P-'MEL.

R RAOIOACTIYI!. WAST£ DISPOSAL. AND SPENT 'FUU.

@]

SIGiHT F'LOW VIC. T-'ULIC.

s

$TEAM s;~LS AND AIR. REMOVAL C. OUPLINfii 5

5

~

NOZZLE DESIGNATIONS USED WITH ABOVE S'YM&OLS FLO~

T TURBINE

~

-+'\\,t-EX P"NS.ION JOINT F UUT LETTEFt, SECOND LITTS" THIRD LETTE.R u

B"f PASS SYSTEM

~

PROCI.S$ 09' MAIN V£NTILATION AND H[ATING STEAM

~

FL£.Xl8LE HOSE LETTER LITTER.

ME~SUIU.MENT FUNCTIC>N w

CIR..CULATIN<a WATER. AND SERVICE. WATER 9

STRAINE.A,.

6 6

I)

DIFFEIUNTIAL CONTROL X

CONTROL AIR PAtSSUR.E s

SWITCH SYSTKM ALARM

'(

--f~ ORIFICE IDENTIFIC.ATION F

P:LOW A

-4L

~

ltN~TRUMIHT L

L.liVRL.

C CON'TltOLL~R

~

FIRE S"f<<J>TEMS THERMAL. SLEEVE Olt.SAMPLE LOC"TI0N )

P"ISSUltE 1

INDICAT01l

--.:r HE'AT T"ACEO SEE LIST T

TEMPElll."TUR~

R

,-rco1tDE~

7 7

R RESISTANCE ORIFICE s

SAMPLE X

i!ST POINT COM~UTER F 0, FAIL OPEN R

R~0IATION q

INPUT 0A1E: "*

DESCR IPTION APPO.

F. C.

FAIL CLOSED REVISIONS PROTECTION F' A t. FAIL._$ l'i

    • nns DRAWIMG IS THE PROPERTY OF THE AMl!RICAN V

Vl&R~TION p

SYSTEM l!Ll!CTltlC POWEi SlltVICE CORP *.t.ND IS LO,,IJ,E0 lPON CO~Ill t>I TK,,T J T IS NOT TO BE l!EPROOUCEO OIi OOPIED, 1"' IIHOL[ ml IN PART,

DR USED FDR FUR-8 8

INPUT L.O. LOCKED OR SEALED OPEN NtSHING llf'OR)l,t,TJON TO ANY PERSOO WITHOUT THE WRITTEN CONSENT a'" TI£ AEP' SERVICE CORP.,OR FQl'I "'"PUMPOU Ot:lRIHEf'IU.L TO THEI R INlEIIEIH,

/'HJ IS TO Ne RETU!NEO UPON REQUE5T' L. C.

LOCKED OR SEALED CLOSED lN~ MICHIGAN POWe:t COMPANY I-L&TTERS IN TOP H~LF 01= SYM!>O~

INDIC.-...TE FUNC.T\\ON ~WD SYSTEM DONALD C. COOK

~

0 M & OUTSIDE M,ss1LE NUCLEAR PLANT Pl'ICHIGAN 2.- NUMBERS IN t,OTTOM M~LF OF SYMe,OL I0ENT\\FY' INDIV\\DV~

0~1t*1e" INSTRUt--'l;NTS OR S~MPLE C.ONNEC'TIONS.

IM&

INSIOE M1$SIL!.

9 9

~"RR\\ER.

DWG. NO.

INSTRUMENT & SAMPLING CONNECTION SYMBOLS ARCH I ELEC I I IECH I I STR I 1~,

DATE!

I CKI DESIGN UGllGllttG Dl,IIJOJII s MllafCAN I AEP SERVICE CORP.

~ c~=~~ffAJ:,5 I-l I

I I

l cM 1 2

J F 4

s.

6 1-l G

[JlGINCH 4 H

l2 ll6 I TENTHS 110 K

120 130 L

IINCHES 11 M

12 1,

N a

IGS0G94 B

C D

E A

Removed per Regulatory Issue Summary 2015-17 INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT BRIDGMAN MICHIGAN PLOT PLAN 9

DWG, NO, ' FSAR FIG. 1.3-1 AR(H I I ELEC MECH I I STR I

--*-*-**1t10111 mau.ccr.11 AEP SERVICE CORP.

1 RIVERSIDE l'I.AZA COWMBlJS. OH..,,.

I 0

Removed per Regulatory Issue Summary 2015-17

~7.48 REVISED PER UCR 2100, REV.0

~7. 51 REVISED PER UCR 2219, REV.0

27. 54 REVISED PER UCR 2220, REV.0 DATE NO.

DESCRIPTION DR.

CHK'D APP'D RMSIONS AMERICAN ELECTRIC POWER TlnE KEY PLAN COOK NUCLEAR PLANT REFER TO DRAWING MICROFILM OR MASTER INDEX FOR NUCLEAR GENERATION GROUP APPROVAL DATES AND SIGNATURES. CCADD-RASTER>

BRIDGMAN, MICHIGAN DWG. NO.

FSAR FIG. 1.3-1A

Removed per Regulatory Issue Summary 2015-17 INDlAHA MICtlOAN POW'ER COMPANY DONALD C. COOK NUCUAR PLAHI'........

SECTIONS "D-D". "E-E" &

"F-F" UNITS NO. 1 & 2 om;. NO. FSAR FIG. 1.3 - 2 A9 URVJC£ CORP.

tRJVEFISIOE nA.ZA COLUltJaU$..OH 4'21$

0 9

Removed per Regulatory Issue Summary 2015-17 INDIANA,.CHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLAN1' PLANT ARRANGEMENT SECTIONS G*G", "H*H",

"J*J I, "K<<"

lt4ITS NO. 1,_ 2

  • Mi. fSAR FIG. 1.3-3

Removed per Regulatory Issue Summary 2015-17 IHDlANA MICHIGAN POWER COMPANY DONALD C. COOK

~

NUCUAJI PIAHT PLANT ARRANGEMENT SECTIONS "L-L" & "M-M" UNITS NO. 1 & 2 9

DWG. Ml. FSAR FIG. 1.3 - 4

""'" I I ! L<C I l1t:CHI I $1A I 1..

a:t,Cll~Ntlrl.SJC..

s-1 A£P SERVICE CCN.

1 NVEMflJE 11.AU

!!m!IC COLUMBUS.OH 4:U1S I

0

Removed per Regulatory Issue Summary 2015-17 flfotANA MICHN3AN POWER COMPA!<tY I DONALD C. COOK NUCLEAR PLANT PLANT ARRANGEMENT SECTIONS "N-N", "P-P",

"Q-0" & "R-R"

~

UNITS NO. 1 & 2 DffllNJ. FSAR FIG. 1.3

  • 5

="I l *m l l ""°' I l.,. I

lc11, IIHKN c-=-a:IIUIO Ol'wtt,...
  • E*I AO SEJlVJCE CORI'.

1 IWIASIDt AAZ.11 COI.V.US. OH Cstt$

I 0

Removed per Regulatory Issue Summary 2015-17 INDIANA MfCHIGAN POWIR COHPAHY DONALD C. COOK

~

NUCUAAPUWT MICH-PLANT ARRANGEMENT PLAN BELOW BASEMENT UNITS NO. 1 & 2 9

DWG-NO. FSAR FIG. 1.3

  • 6

'"°' I l lil.<<I l,.<>< 11.,. I I"'

I<*

OC:S1oi.t111PC(11 D111> t 1Vmdw

=-1 All' se,rv,c~ CON',

t N WR$mt MAZA

=:="

Cot.~ OH 4.WS I

0

Removed per Regulatory Issue Summary 2015-17 INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT BRIDGMAN MICHIGAN PLANT ARRANGEMENT BASEMENT PLAN EL 591'-0" & 587'-0 UNITS 1 & 2 DWG, NO, FSAR FIG. 1. 3-7 ARCH SCALE**

DATEI

  • ELEC MECH STR DR**

CHI*

REFER TO ORIGINAL ISSUE MICROFILM FOR SIGNATUR ES AEP SERVICE CORP.

1 NVERSIDE l'I.AZA OOWMBUS. OH..,,.

0 9

Removed per Regulatory Issue Summary 2015-17 INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT BRIDGMAN MICHIGAN PLANT ARRANGEMENT MEZZANINE FLOOR EL. 609' -0 11 UNITS 1 & 2 9

DWG. NO. fSAR FIG. 1.3-8 ARCH ELEC MECH STR SCALE:

  • D*TE1
  • DESIGN ENGIICERING DIVISION*

REFER TO ORIGINAL ISSUE MICROFILM FOR SIGNATURES flJJflJlflitR AEP SERVICE CORP.

1 RIVERSIDE PlAZA POWa COLUMBUS, OH 43216 I

0

Removed per Regulatory Issue Summary 2015-17 INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT BRIDGMAN MICHIGAN PLANT ARRANGEMENT TURBINE BUILDING MAIN FLOOR EL 633' -0" UNITS 1 &. 2 9

DWG. NO. FSAR FIG. 1. 3-9 ARCH ELEC MECH STR SCAl.11

  • DAl'II
  • OU*

DESIGN ENGINEERING DIYISIONI

=JIMfRICAN AEP SERVICE CORP.

B.KJRIC 1 RIVERSIDE PLAZA POWER COLUMBUS, OH 43215 I

0

Removed per Regulatory Issue Summary 2015-17 INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT BRIDGMAN MIQIIGAN PLANT ARRANGEMENT REACTOR BUILDING MAIN FLOOR EL 650'-0" 9

l.tl!TS NO. I ~ 2 DWG, NO, FSAR FIG. 1.3-10 AllCHll*uc MECH I I STR I 0.ftl *

  • IIOII IIIOIICPN OlvlllCINI t:!1:=="

AEP SERVICE CORP.

1 RIVERSIDE PLAZA COWMBUS, OH 43215 I

0 fsar-fig-1.3-10_23.dgn 08/28/2010 12:56: 13 PM

STANDARD SYMBOLS FSAR FIG. 1.3

- 11 L.O. LOCKED OR SEALED OPEN L.C. LOCKED OR SEALED CLOSED A

I B

I C

I D

I E

I F

I G

I H

I J

I K

I L

I M

I N

I 0

u-£T91~ H'lfS~ 'ON '9Ma I INSTRUMENTATION AND SAMPLING FIRST LETTER V~LVES e

IOENTIFf CATION LIST

&l TR1'NSMITTED SA.MPLI!

t><l &~TE sA,ETY I

I A

AUXILIAR"t' STE~M AND FEED PUMP TURBINE STE1'M C83

~

GLOBE.

ANGIL£ e

STEAM GENERATOR LOG,r,,.L. S,-.MPI.E.

C CONDENSATE ANI) COOLING WAT&:R

~

NO"-MALLY CLOSED t<] CHECK t-LOC.ALLY R&.MOTE D

DRIPS, D~AINfi "ND WArtMING STE"M

~ BUTTER~LY ten STOP C~RCK 2

2 MOUNTED MOUNTED E

ENVIRONMENTAL MOHITO,-.IMG

+

e E3 F

F"EE DWATE'"

~

THR£1 W"'<

FLOAT CHI.C.K NON-TA.~KSMITTIMtit 6

GAS SYSTEMS (1!.'ICCl:PT FIR.I. FIGHTING CO2,.)

~

DIA.PtlRlti.titM Cfl NEEOLE H

HEATE" BLE.E:DS "ND DRAINS e

B X

SAFETY INUGTI0N1 RESIDUAL HEAT "EMO"A\\.. t CONTAINMENT SPR"Y VALVE OPERATO~S 3

3 TRA.NSMITTINEii TO MMM CONTROL ROOM J

~

c(:

k CONO~NSATE,i.No CHEMICAL $ERV ICES AIR COCK 8

B LU&E OIL ANO ELEC.TRO-HYDR~ULIC CONTROL. FLUID

~

TRANSMliTlN<il TO sue>>-P"NEL L

~.:: SOLENOID

~., AilR PISTON MAIN STEAM

-.a M

~

N NUCLEAR REACTOR COOL~NT l!I..NO IN-C.oR.E \\NS.TR.UMl:.NTS 4

4 ELECTRIC MOTOR 1-.,LOC.~LLV MOUNTEO"' INSTRVMENT: ON Jti. PIPE, C.OLVMN, OR 0

INSTRUMENT 5T~MD INC.LOSE PROXIMITY TO SENSINEi POINT.

p PLANT AIR MISC. SYMBOLS 2.-"'REMOTi PA.MEL MOUNTE.D.\\MSTRUMEtllT: SIEtN~L S\\IJN D\\REc.TLV

~

CHEMICAL AND VOLUME CONTROL FROM SENSING POINT TO M"-\\N C.ONTROL P"NEL. OR sue-P"MEL.

R RADIOACTl'VI!. WAST£ DISPOSAL. AND SPENT 'FUS: L.

@]

SIGHT FLOW

-Q-VIC. T~VLIC.

AIR. REMO\\IAL COVPL\\N" 5

5 s

~TEAM SkALS AND

~

FLOW NOZ. ZLE DESIGNATIONS USED WITH ABOVE S"MBOLS T

TURBINE

REFERENCES:

+\\,+-

[)(.PANSION JOINT u

B"'(PAS'S SYSTEM

~

FIRS,,T LETTEI\\ SECOND LITTI" THIRD LETT£R PROClSS OR MAIN V.E.NTILATION AND HEATIN6 STEAM

~

FLE.X18LE HOSE LETTE~

LITTEil MEASUUMENT FUNCTION w

CIR.CULATINC. WATER AND SER\\/IC.E WATER 9

STR ~INEA.

6 6

I)

DIFFE"lNTI AL.

CONTROL X

CONTROL AIR PRESSURE s

SWITCH

-u-ORIFICE SYSTEM F

~LOW A

ALARM y

IDENTIFICATION

..dL l lNSTftUlll!NT L

L.EVEL.

C C0NTltOLL&.I\\

~

FIRE SY':,TEMS THE.RMA\\.. SLEE.VE OR S~MPLE LOCATION )

p PR.ltSSU9'E 1

INDI CAT01'

~

HrAT T1'ACED 7

7 SEE LIST T

TEMPERA"tURl R

"ltCORDER R

R£.SISTANCE. ORIFICE s

SAMPLE' X

TEST POINT It,.~ :i!0~~~R~f~zUCR 98-UFSAR-0409, COM~UTER F 0.

FAIL OPEN R~OIATION q

DATE "*

DESCRIPTION APPD -~

INPUT F. C.

FAIL CLOSED REVISIONS FILENAME: fsar-lig-1-3-11.163 (raster file): fsar-lig-1-3-11 163.cit PROTECTION FA 1, FAIL ~$ IS

'TtUS DRAWING IS THE PROPERTY OF TI--E AMERICAN ELECTRIC POWER SERVICE CORP. AND IS LOANED V

Vl&RI\\TION p

SYSTEM UPONCONOITIONTHATITISNOTTOBEREPRODUCED QR COPIED, W olHOL.E OR IN PART, OR USED FOR FUR-E 8

INPUT NlSHHIG !NFORHATIDNTOANY PERSON WITHOUT THE WRITTEN CONSENT OF HE Al:P SERVICE CORP., OR eOR,1.NYPURPOSEDETRIMENT,1.LTOTHO:IRINTERE$T, ANDISTOBERETURNEDVPONREQUEST' INDIANA MICHIGAN POWER COMPANY I-LETTER5 IN TOP H"l.F Of SYM!>OL INDIC.~TE FUNC.T\\ON It.WI) SYSTEM DONALD C. COOK -

0 M & OUTSIDE M\\SS\\LE NUCLEAR PLANT BRIDGMAN MICHIGAN 2-NUMf>ERS IN e>>OTTOM 14~LF OF &YMe,OL IOENT\\FY tNOIV\\DV-._L D~tta,eR.

INSTRUMENTS OR 51'.MPLE C.0NNECTIONS.

INSIDE M15CalLE

\\M 6 9

9

&"R.P.IER.

DWG. ND.

INSTRUMENT SAMPLING CONNECTION SYMBOLS ARCH I ELEC I I MECH I I STR I I"'

DAT[I I<><*

IESION EMG!tl:ERING DlWISl<N

=

JIMUICAN I AEP SERVICE CORP.

~~RIC c~ffftr:fff~~z:,5

+

116 J

l,rnrno Im K

I'° ho L

ITNn1F"~

11 M

1, 13 N

I 0

I I

~

I n

I

~

~ c' <I TI 13*--**-** 4 H

12