IR 05000327/2021401

From kanterella
(Redirected from ML21111A176)
Jump to navigation Jump to search
NRC Inspection Report 05000327/2021401 and 05000328/2021401 (U)
ML21111A176
Person / Time
Site: Sequoyah  Tennessee Valley Authority icon.png
Issue date: 04/21/2021
From: Otis Smith
Division of Reactor Safety II
To: Jim Barstow
Tennessee Valley Authority
References
IR 2021401
Download: ML21111A176 (4)


Text

April 21, 2021

SUBJECT:

SEQUOYAH NUCLEAR PLANT, UNITS 1 AND 2 - NRC INSPECTION REPORT 05000327/2021401 AND 05000328/2021401 (U)

Dear Mr. Barstow:

On March 25, 2021, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Sequoyah Nuclear Plant, Units 1 and 2, and discussed the results of this inspection with you and other members of your staff. The results of this inspection are documented in the enclosed report.

One finding of very low security significance (Green) is documented in this report. This finding involved a violation of NRC requirements. We are treating this violation as a non-cited violation (NCV) consistent with Section 2.3.2 of the Enforcement Policy.

If you contest the violation or the significance or severity of the violation documented in this inspection report, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN:

Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region II; the Director, Office of Enforcement; the Director, Office of Nuclear Security and Incident Response; and the NRC Resident Inspector at Sequoyah.

The following cross cutting aspect was assigned to a finding using Inspection Manual Chapter 0310 Aspects Within Cross Cutting Areas: [H.8] - Procedure Adherence.

If you disagree with a cross-cutting aspect assignment in this report, you should provide a response within 30 days of the date of this inspection report, with the basis for your disagreement, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region II; the Director, Office of Nuclear Security and Incident Response; and the NRC Resident Inspector at Sequoyah. This letter will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

The enclosed report contains Security-Related Information, so the enclosed report will not be made publicly available in accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390(d)(1). If you choose to provide a response that contains Security-Related Information, please mark your entire response Security-Related Information-Withhold from public disclosure under 10 CFR 2.390 in accordance with 10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390(b)(1). The NRC is waiving the affidavit requirements for your response in accordance with 10 CFR 2.390(b)(1)(ii).

Sincerely,

/RA/

Otis Smith, Jr., Acting Branch Chief Plant Support Branch Division of Reactor Safety

Docket Nos. 05000327 and 05000328 License Nos. DPR-77 and DPR-79

Enclosure:

As stated

cc w/o encl: Distribution via LISTSERV

cc: See Page 3 cc:

Mr. Scott W. Hunnewell Plant Manager (Acting)

Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 POB 2A-SQN Soddy Daisy, TN 37384-2000

Mr. Matthew R. Lovitt Director, Plant Support Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 OPS 4A-SQN Soddy Daisy, TN 37384-2000

Jeffrey R. Sowa Manager, Site Licensing Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 OPS 4A-SQN Soddy Daisy, TN 37384-2000

Mr. C. E. Glover (safeguards info):

Director, Nuclear Security Tennessee Valley Authority 1101 Market Street, LP 1A Chattanooga, TN 37402-2801

Mr. Brian E. Brigman Senior Manager, Nuclear Site Security Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000, MPB 1A-SQN Soddy Daisy, TN 37384-2000

ML21111A176 (Cover Letter)

Cover Letter:

X SUNSI Review X Non-Sensitive Sensitive X Publicly Available Non-Publicly Available OFFICE RII/DRS/PSB RII/DRS/PSB RII/DRS/PSB RII/DRP/BR5 DII/DRS/PSB

NAME J. Justice J. Tornow J. Wallo T. Stephen O. Smith

DATE 04/21/2021 04/20/2021 04/20/2021 04/20/2021 04/21/2021