3 to Updated Final Safety Analysis Report, Drawing, 4M721-5877, Reactor Core Isolation Cooling Simplified Drawing Initial Cooling Following Main Condenser Isolation
ML21055A374
Person / Time
Site: Fermi, 07200071  DTE Energy icon.png
Issue date: 02/02/2021
From:
DTE Electric Company
To:
Office of Nuclear Reactor Regulation, Office of Nuclear Material Safety and Safeguards
Shared Package
ML21055A091 List: ... further results
References
NRC-21-0002
Download: ML21055A374 (1)


Text

D C

B A

4 CONDENSATE STORAGE Pll00A005 P1100F042 REACTOR VESSEL HIGH WATER LEVEL INITIATE RCIC TURBINE TRIP 4

B2~LS

~ N693...

B21

~E41 SPARGER RING PRIMARY CONTAINMENT HIGH STEAM e.P INITIATE RCIC TURBINE TRIP &

CLOSE VALVES F007, FOOS,

__ j__ __ _J STEAM LINE FEEDVATER LINE B21Nl SUPPRESSION PL 3

REACTOR VESSEL PRESSURE LOV-INITIATE RCIC TURBINE TRIP & CLOSE VALVES F007, FOOS VENT--~

2 r------

1 I

REACTOR VESSEL LV VATER LEVEL -

INITIATE RCIC

_ SIGNAL PENS VALVES _____ _J I

I L -

-~+-l(

E5100 I....,

F040 I :,;

I f:'l I§ I'.::

I~

I "'

E5100 I F030 I

I I

I I

,---,-----------------7 I

I I

0---=;:

SPECTACLE Fl.ANG[

E5150JJ006 riff~

PSE

~

N020 CNTRL MINIMUM L_,J fLV BYPASS RCIC PUMP E510IC001

[5100 i____w F016

~

'----'I'---,

I I

I E5100 I

[5100 F021 FOIi I

L - - - - -f----+---t I

I

'>f-+'""- - J RCIC TURBINE E5101C002 BAROMETRIC CONDENSER E5100B001 A

F004 VALVES CLOSE WHEN F045 IS NOT FULLY CLOSED DRAIN POT AO F025 AO F026 VALVES CLOSE WHEN F045 IS NOT FULLY CLOSED 1

SIGNALS TO INITIATE RCIC TRIP INSTRUMENT ACTION REACTOR VESSEL B21 LS OPEN* FO!O, LO\\/ \\/ATER LEVEL N692A,B,C,D FOl2, F13, F45 F095 CLOSE* F022 SIGNALS TO ISOLATE RCIC TRIP INSTRUMENT ACTION RCIC EQUIPMENT ROOM TEMPERATURE TSE N602A,B HIGH CLOSE* F007

FOOS, RCIC STEAM MYE N657A,B TRIP RCIC LINE FLO\\/-

MYE N660A,B TURBINE HIGH RCIC STEAM SUPPLY PRESSURE-MYE N658A,B,C,D LO\\/

HIGH RCIC TURBINE MYE N655A,B,C,D EXHAUST DIAPHRAM DIAPHRAMS PRESSURE RUPTURE 150 +/- 10 PSIG SIGNALS TO TRIP RCIC TRIP INSTRUMENT ACTION REACTOR VESSEL B21 HIGH \\/ATER LS N693A,B LEVEL RCIC TURBINE, 2

122,3"/. RA TED OVERSPEED SPEED TRIP RCIC HIGH RCIC 25 PSIG TURBINE TURBINE EXHAUST PSE N009A,B PRESSURE LO\\/ RCIC PUMP 20' HG VAC SUCTION PSE N006 PRESSURE NOTES*

FDR TECH SPEC SETTING VALVES, REFER TO TECH, SPECS, 2,

ALL INSTRUMENTATION SHO\\IN ON THIS DIAGRAM SHOULD BE PREFIXED BY ES! UNLESS NOTED DTHER\\IISE, 3,

ALL VAL YES AND ORIFICES SHO\\IN ON THIS DIAGRAM SHOULD BE PREFIXED BY E5150 UNLESS NOTED OTHER\\IISE, 4, VAL VE F095 CLOSES ONCE LEVEL 2 SIGNAL IS ND LONGER PRESENT.

4M721-5877 LATEST REVISION G

NUCLEAR SAFETY RELATED THIS IS A MICROSTATION PRODUCED DRAWING.

CHANGES OR REVISIONS MUST BE BROUGHT TO THE ATTENTION OF THE PLANT ENGINEERING DESIGN GROUP TO ENSURE THAT CONFIGURATION CONTROL IS MAINTAINED.

THIS DRAWING WAS REFORMATTED BY MICROSTATION AT REVISION *E*. ALL PREVIOUS APPROVAL SIGNATURES ARE ON F1LE ON MICROFILM IN DOCUMENT CONTROL.

INC.CODE Detroit Edison Fermi 2 G DCD'S INCORPORATED:

A PORTION OF THIS DRAWING IS AFFECTED BY THE FOLIDWING:

PREPARED BY u DATE TITLE REACTOR CORE ISOLATION COOLING SIMPLIFIED DRAWING INITIAL COO LING FO 110 WING D

C B

CHECKED BY DATE MAIN CONDENSER ISOLATION A

l--------------t---t------,----==~-t--=7---______________


i OTHER REVISIONS:

APERTURE CARD TITLE EDP 36178.B009, REV. \\'l TC CHANGE DOCUMENT UFSAR FIG. 5. 5-9 f-----t-----------J--~AP!::P~R~O~VE_!eD!!_2B!._!Y~-l---__!llAU:TEJ!i_--t PLANT IDENTIFICATION SYSTEM NUMBER E5100 ARMS RECIPIENT #

DATE DATE DOCUMENT TYPE CODE NUC OPS FILE NO.

DATE ISSUED TO JS 3/31/11 s,(~_..,, 1--:::::-::::::=-==:-:::=:::--::=--r,_

_-.!,!-OTHEg~~R-_;-AP;i:'!'.)P-R~OtyVAli3~&-=r~::;;D~A-TEf£C~J__ _____ ___..:D~D~D-!...M:!:!=.E~C=--_L _ _:1B'.'.'.:0'.:.1 __ j_~S::2'_::-_:9~Lo~-:...:10,l _ __j f-AP=Ps,,R;;;O:;;VE;;;;D"-'BOuY~----1--=

77,CC,/_.,c;'.<):,-',:;l~'!::E-""::~----f,;D~ATE;;;;;-7 EDP POSTING ENTRIES REQUIRE THE DRAWING NUMBER

<./ &a M'"'l.:5£,,,F

-J!64o{f ADDITION~~~;1:~ CODE:

4 M7 21-5 8 7 7 PREPARED BY IJJ ADLER REV.

G 3

2 1