D C
B A
4 3
2 1
RV PRESS LO\\/
SIGNAL PENS VALVES CSS AND LPCI INJECTION VAL VE OPENING PERMISSIVE r.,..----
7 1 +
I I
I I
I I
I I
I I
I I I
I I
I I
I HIGH PRifci~:E CONTROL MINIMUM CONDENSATE STORAGE TANK PllOOAOOS Pl!OO F043 I
I I
I I
I I
I I
I I
I I
I I
I I
I 1
B21~,s N690
.c.
I B21 I
FLO',/ BYPASS,
/~JII1lID--P,+/-:;!;---!iJ-1-~~,i.---i>1<:Jil_......1. __ -<3>_A __,_,_,_'_,_',_,.,.,_-;1* ----------------~~:~~-~-~lr'-
I' F012B I
I RV LEVEL LO',/
I START S. B, DIESEL GEN.
I I
I I
I I
I I
I I
I I
+ r i..+- HIGH DRY',/ELL PRESSURE I
+ I I
I I
I I
I I
I I
I I
I I
I I
I
__ B_:~~
.B.C LB_.?1
__ B_:~~~
,B,C, I
B21 REACTOR VESSEL PRESSURE ABOVE CORE PLATE PRIMARY CONTAINMENT
! t I
I SIGNAL PUMP START L...-l------------*----------------------- -------7 4
I L ___..J'---
A DCD'S INCORPORATED:
OTHER REVISIONS:
Revised I&C tmndnture 'FIS' to 'rS' in zone C-2/3 per CARD 09-26064 (Reference LCR 09-054-UFSl.
PREPARED BY L BRITT / A. PATEL APPROVED BY 3
,~r 0-MO F0l5 HIGH PRESSURE ALARM SUPPRESSION POOL ALLOW AOS I §--
PUMP A F0l5 moo f037A r-
+-------7----E2101 COO!A T
I I
I L-----+-
--+-.L-E2100 F032A.,._,.,r-~
E2100 LOY PRESSURE ALARM ALLOW ADS
_L
~
I I
PUMP B PUMP C E2101 E2101
- COOIC COOIB; I
I E2!00 F037B r-1rnoo
_jF037D I
I I
L-
---11>--'
E2!00 ALLOW ADS
~
~
E2!00 F003D I
E2!00 FOOIA F002A E2100 E2!00 FOO!B 002B E2100 FOO!C FOO!D E I 0 FOl9 SYSTEM TEST OPERATED BY REMOTE MANUAL CONTROL
- 1. TEST ONE LOOP AT A TIME. CORE SPRAY LOOP A IS SHOWN, LOOP B IS TYPICAL.
NOTES:
- 1. FOR TECH SPEC SETTING VALUES REFER TO TECH SPECS.
- 2. ALL VALVE NUMBERS AND PIPING ORIFICES SHOWN ON THIS DIAGRAM ARE PREFIXED BY E215O UNLESS NOTED OTHERWISE.
- 3. ALL INSTRUMENT NUMBERS SHOWN ON THIS DIAGRAM ARE PREFIXED BY E21 UNLESS NOTED OTHERWISE.
- 4. THIS Dll'G. SHOULD NOT BE CONSTRUED AS THE CONTROLLED P&ID OF THE CORE SPRAY SYSTEM.
4M721-5869 LATEST REVISION A
NUCLEAR SAFETY RELATED THIS IS A MICROSTATION PRODUCED DRAWING.
CHANGES OR REVISIONS MUST BE BROUGHT TO THE ATTENTION OF THE PLANT ENGINEERING DESIGN GROUP TO ENSURE THAT CONFIGURATION CONTROL IS MAINTAINED.
THIS DRAWING WAS REFORMA'ITED BY MICROSTAT!ON AT REVISION "A". ALL PREVIOUS APPROVAL SIGNATURES ARE ON FILE ON MICROFILM IN DOCUMENT CONTROL.
INC.CODE Detroit Edison Fermi 2 TC A PORTION OF THIS DRAWING IS AFFECTED BY THE FOLLOWING:
CHANGE DOCUMENT PREPARED BY CHECKED BY u
DATE DATE TITLE TEST CORE SPRAY SYSTEM MODE DURING PLANT OPERATION USING SUPPRESSION POOL APERTURE CARD TITLE UFSAR FIG 6.3-9 f----+-------------!---AP=P~R~O~VE=D'....!cB~Y--!-_gA11:TE=.--J PLANT IDENTIFICATION SYSTEM NUMBER E2100 ARMS RECIPIENT#
EDP POSTING ENTRIES REQUIRE THE ADDITION OF THE ARMS STATUS CODE:
EITHER
- AFC" OR
- ASB"
! DOCUMENT TYPE CODEDDDMEC OTHER APPROVALS DATE NUC OPS FILE NO.
DATE ISSUED TO IS
- _c::: __
1B01 DRAWING NUMBER 4 M7 21-58 6 9 A
2 1