ML20353A278
| ML20353A278 | |
| Person / Time | |
|---|---|
| Site: | Westinghouse |
| Issue date: | 12/18/2020 |
| From: | Westinghouse |
| To: | Office of Nuclear Material Safety and Safeguards |
| Shared Package | |
| ML20353A275 | List:
|
| References | |
| LTR-RAC-20-94, EPID L-201-RNW-0016 | |
| Download: ML20353A278 (12) | |
Text
WESTINGHOUSE NON-PROPRIETARY CLASS 3 to LTR-RAC-20-94 Date: December 18, 2020 Response to Request for Additional Information March 2019 Environmental Report Updates
WESTINGHOUSE NON-PROPRIETARY CLASS 3 to LTR-RAC-20-94 Date: December 18, 2020
Page1of11
RAI 15 - ENVIRONMENTAL SAMPLING VALUES Table 6.1-2 Typical Environmental Program Radiological Analytical Sensitivities TYPE OF SAMPLE ANALYSES TYPICAL SAMPLE QUANTITY NOMINAL MINIMUM DETECTION LEVEL Air Particulates Alpha 571 Cubic Meters 6.0E-14 µCi/ml Surface Water Uranium 1 Liter 0.5 pCi/l Tc-99 1 Liter 50 pCi/l Well Water Uranium 1 Liter 0.5 pCi/l Tc-99 1 Liter 50 pCi/l River Water Uranium 1 Liter 0.5 pCi/g Tc-99 1 Liter 50 pCi/l Sediment Uranium 100 Grams 0.5 pCi/g Tc-99 100 Grams 1 pCi/g Soil Uranium 100 Grams 0.5 pCi/g Tc-99 100 Grams 1 pCi/g Vegetation Fluoride 100 Grams Variable (based on dilution level)
Uranium 100 Grams 0.5 pCi/g Tc-99 100 Grams 1 pCi/g Fish Uranium 1 Kilogram 0.5 pCi/g Tc-99 100 Grams 1 pCi/g
WESTINGHOUSE NON-PROPRIETARY CLASS 3 to LTR-RAC-20-94 Date: December 18, 2020
Page2of11
RAI 18 - GENERAL WATER RESOURCES To acknowledge the additional information collected regarding private water supply wells and to address RAI 18, items A and B, a new sub-section was added to Section 3.1, Land Use of the ER. The new sub-section was added as 3.1.1 and entitled Private Property. The remaining subsequent sections were unaltered except for being renumbered.
3.1.1 Private Property In October of 2019, a private water supply well survey was conducted within a 1-mile radius of the facilitys property boundary. Four private water supply wells (WSW-01 through WSW-04) located west northwest, southwest and south of CFFF. The private well locations are depicted in Figure 14 of the Final Interim Remedial Investigation Data Summary Report (AECOM 2020).
These locations are side to downgradient of the known extent of groundwater impact at the facility.
Prior to collecting the groundwater samples from the private water supply wells, CFFF personnel obtained access agreements from the property owners (AECOM 2020).
Well WSW-01 runs for long periods of time and is used by a private hunt club to fill a pond. Wells IWSW-01 and IWSW-02 are small diameter wells that are no longer in service and are located on the same private hunt club as well WSW-01. Potable water is supplied to this hunt club by the City of Columbia. Well WSW-03 provides potable water to another private hunt club. Wells WSW-02 and WSW-04 provide potable water to two private cabins. Westinghouse was unable to locate design information for these private wells (AECOM 2020).
Three of the four private water supply wells are located within the 1-mile private water supply well search radius of the site property boundary as specified in the Final RI Work Plan (AECOM 2019c).
The fourth private water supply well is between the southern edge of this radius and the Congaree River. The closest private water supply well, WSW-03, is approximately 5,400 feet (over 1 mile) downgradient of the known extent of COPC impact.
Groundwater samples from these four private water supply wells did not contain COPCs above their respective MCLs. Concentrations of U-238, fluoride, nitrate, ammonia and antimony were detected in the groundwater samples at concentrations below their respective MCLs and are not related to groundwater impact caused by manufacturing operations at the site.
As discussed in the Westinghouse Final Interim Remedial Investigation Data Summary Report (Section 3.7) prepared by AECOM, analysis of groundwater samples from four private water supply wells identified no COPCs related to manufacturing operations at CFFF (AECOM 2020, Westinghouse 2020).
WESTINGHOUSE NON-PROPRIETARY CLASS 3 to LTR-RAC-20-94 Date: December 18, 2020
Page3of11
RAI 18 - GENERAL WATER RESOURCES & RAI 19 - FATE AND TRANSPORT ASSESSMENT ER Revision of Section 3.4.1, Groundwater to address RAI 18 Item C and RAI 19 Item B:
3.4.1 Groundwater Groundwater levels reflect both the climatic conditions of the region and groundwater withdrawals.
The groundwater level also depends upon a combination of the permeability of the strata and the hydraulic head. The inclination of different strata may cause the water tables in the surrounding area to be higher or lower than the water level in the nearby Congaree River since movements of the groundwater are, to a large extent, independent of the river. Because of friction encountered by water in its passage through pervious strata, the water table is not always horizontal. Several water tables may exist at different levels, separated by impermeable strata.
Regional Area Groundwater in the Upper Coastal Plain occurs in multiple aquifer systems, mostly under artesian or confined conditions. These aquifers consist of rocks of Paleozoic age and are typically composed of one to several layers of eastward thickening, permeable sands or limestone split by discontinuous, clay-rich materials. Confining units, consisting of clay-rich sediments, exist above and below the aquifers. Aquifers found below the site are the Peedee, Black Creek, and Upper Cape Fear with the Peedee aquifer being the closest to the surface. In large portions of these aquifers, sands and limestone materials are so well connected that withdrawals cause pressure reductions many miles from the pumping center.
The upper Cape Fear aquifer is present in the western portions of the Coastal Plain at elevations of 90 m to 463 m (295 ft to1,519 ft), with an average elevation of 76.2 m (250 ft). The upper Cape Fear aquifer varies in thickness from 2.4 to 203 m (8 to 665 ft) thick and averages 46 m (50 ft) thick. The aquifer is composed of very fine to coarse sands and occasional gravels. Wells typically yield 757 to 1,514 L/min [200 to 400 gpm].
The Black Creek aquifer is present in the central and southwestern portions of the Coastal Plain.
Elevations range from 97 m to 368 m (317 ft to 1207 ft) and average 41 m (135 ft). The thickness of the Black Creek aquifer ranges from 5 -296 m (18 to 972 ft) thick, averaging about 53 m (175 ft) thick. The aquifer is composed of very fine to fine salt and pepper sands. Wells typically yield 757 to 1514 L/min (200 to 400 gpm).
The Peedee aquifer is present in the central to southeastern portion of the Coastal Plain at an average elevation of -9 m (-30 ft). Elevations vary from 35 m to -243 m (114 ft to -796 ft). The thickness of the aquifer ranges from 2.4 m to 123 m (8 to 404 ft) thick and averages about 41 m (135 ft) thick. The Peedee aquifer is composed of fine to medium sand, and wells typically yield up to 757 L/min (200 gpm).
Site Area
WESTINGHOUSE NON-PROPRIETARY CLASS 3 to LTR-RAC-20-94 Date: December 18, 2020
Page4of11
The average depth to the water table in the area of the CFFF site is approximately 4.6 m (15 ft).
Since September 1971, the highest mean water level recorded was at 0.9 m (2.95 ft) below the land-surface datum, and the lowest level was 13.66 m (44.83 ft) below the land-surface datum.
The CFFF is located in the Upper Coastal Plain physiographic province. The CFFF is underlain by three hydrogeologic units: the surficial aquifer, Black Mingo aquifer, and Middendorf aquifer.
Groundwater in the surficial aquifer occurs under unconfined (water table) conditions and generally flows from areas of higher topography in the vicinity of the plant building towards areas of lower topography in the floodplain of the Congaree River along Mill Creek. Previously, the water table aquifer above the bluff and the water table aquifer below the bluff were described as the two separate aquifers: the surficial aquifer and the floodplain aquifer. Although the river terrace sediment above and below the bluff were deposited during different time periods, the deposits are of similar lithology and have been found to be connected based on data collected during Phase I of the RI. Since groundwater flows continuously from above the bluff into the floodplain in a single surficial aquifer, groundwater above the Black Mingo confining clay will be referred to as the surficial aquifer henceforth (AECOM 2020a).
Surficial aquifer sediments generally occur to a depth of 30 to 40 feet below land surface (BLS),
both above and below the bluff, and consist of clay, silt or silty sand at the surface coarsening downward to coarse sand and gravel on top of the Black Mingo confining clay. Silt and clay lenses occur at varying depths with the coarsening downward sands of the surficial aquifer. One notable surficial aquifer total thickness anomaly was discovered during Phase I of the RI near the location of monitoring well W-95, where there is over 80 feet of sediment above the Black Mingo confining clay. Further assessment in this area will be performed during Phase II of the RI (AECOM 2020a).
Groundwater monitoring wells were installed at differing depths to assess COPC migration within the surficial aquifer. Monitoring wells installed near the top of the surficial aquifer are designated as surficial aquifer upper zone monitoring wells, whereas wells installed on top of or within 5 feet of the Black Mingo confining clay are designated as surficial aquifer lower zone monitoring wells.
One exception of the criteria above is well W-95. Monitoring well W-95 is designated as a surficial aquifer lower zone monitoring well because chlorinated volatile organic compounds (CVOCs) migrating within the lower zone of the surficial aquifer are found in it and the Black Mingo Formation is anomalously deep at this location (AECOM 2020a).
There is a dynamic relationship between surface water in the ditches that transect the site above the bluff and groundwater in the upper zone of the surficial aquifer. The ditches continually or intermittently receive discharge of groundwater from the upper surficial aquifer depending on the elevation of the water table. The northern portions of the ditches are above the elevation of the seasonal high water table and thus the ditches at these locations are often dry. Runoff from precipitation that enters the dry portions of the ditches may infiltrate the water table, temporarily recharging the surficial aquifer. The southern portions of the ditches where the ditches are deeply incised may intermittently be above or below the water table, depending upon the extent of incisement and seasonal variations in the elevation of the water table. Middle portions of the ditches may recharge the shallow aquifer during low water table conditions and may receive groundwater discharge during high water table conditions (AECOM 2020a).
The predominant direction of groundwater flow in the surficial aquifer is to the southwest with components of flow to the south and southeast. Discharge of groundwater to the deeply incised
WESTINGHOUSE NON-PROPRIETARY CLASS 3 to LTR-RAC-20-94 Date: December 18, 2020
Page5of11
portions of the ditches appears to influence groundwater flow and COPC migration within the upper zone of the surficial aquifer. The Gator Pond also appears to influence COPC migration as evidenced by COPC impacts in surficial aquifer groundwater migrating in a more easterly or westerly direction in the vicinity of the Gator Pond (AECOM 2020a).
The surficial aquifer is underlain by a confining unit composed of dry silt/clay and brittle shale of the upper Black Mingo Formation. Previous geologic cross sections (AECOM, 2013) and Phase I of the RI indicate that the Black Mingo confining clay ranges in thickness from 39 to 83 feet.
Beneath the clay confining unit is an artesian sand aquifer within the lower Black Mingo Formation known as the Black Mingo aquifer. Groundwater flow in the Black Mingo aquifer is inferred to the southwest based upon groundwater elevations from the four monitoring wells that are screened within this aquifer (AECOM 2020a).
The Middendorf Formation occurs below the Black Mingo Formation. Sediments of the Middendorf Formation generally consist of multi-colored clay interbedded with fine to coarse grained sand. Subsurface investigations at CFFF have not extended into the Middendorf aquifer since there is no potential that it has been impacted. The Middendorf aquifer is unconformably underlain by bedrock (AECOM 2020a).
Previous hydraulic characterization by AECOM Technical Services, Inc. (AECOM) and Rust Environment and Infrastructure (Rust), estimated the average linear flow velocity in the surficial aquifer to be 0.42 feet per day or 153 feet per year. The potential for flow between the surficial aquifer and the Black Mingo aquifer was previously assessed to be downward at vertical hydraulic gradients ranging between 0.04 and 0.1 feet per foot (Rust 1995 and AECOM 2013). However, low moisture content and vertical hydraulic conductivities of less than 10-7 centimeters per second (S&ME, 1982) throughout the 39 to 83 foot thickness of the Black Mingo confining clay preclude migration of groundwater between the surficial aquifer and the Black Mingo aquifer which in turn precludes potential migration to the Middendorf Aquifer (AECOM 2020a).
The state of South Carolina regulations R61-68, Water Classifications and Standards considers all groundwaters to be drinking waters.
WESTINGHOUSE NON-PROPRIETARY CLASS 3 to LTR-RAC-20-94 Date: December 18, 2020
Page6of11
RAI 18 - GENERAL WATER RESOURCES ER Revision of Section 10.0, List of References to address Item F of RAI 18:
4.0 LIST OF REFERENCES AECOM 2011. Personal Communication from C. K. Suddeth and D.P. Sanders of AECOM Technical Services to C. Logsdon of Westinghouse Electric Company, Source Investigation Report, Westinghouse Electric Company, Columbia Fuel Fabrication Facility, Richland County, South Carolina, SCDHEC Site ID #00456 (June 15, 2011).
AECOM 2013. Remedial Investigation Report prepared for Westinghouse Electric Company.
AECOM Project No. 60302740, December 31, 2013. Submitted to SCDHEC on January 3, 2014 via Westinghouse document LTR-RAC-14-2.
AECOM 2017. CVOC Field Screening Report" prepared for Westinghouse Columbia Fuel Fabrication Facility. AECOM Project No. 60528361, December 14, 2017.
AECOM 2019. CVOC Assessment Report" prepared for Westinghouse Columbia Fuel Fabrication Facility. AECOM Project No. 60585917, January 11, 2019. Submitted to SCDHEC on January 11, 2019 via Westinghouse document LTR-RAC-19-3.
AECOM 2019b. Preliminary Human Health Risk Assessment" prepared for Westinghouse Columbia Fuel Fabrication Facility. AECOM Project No. 60595649, March 2019.
AECOM 2019c. Final Remedial Investigation Work Plan, Westinghouse Columbia Fuel Fabrication Facility. Consent Agreement #19-02HW, (June 2019).
AECOM 2020. Final Interim Remedial Investigation Data Summary Report, Westinghouse Columbia Fuel Fabrication Facility. Consent Agreement #19-02-HW. (Revised July 2020).
Please note that this document was submitted with a cover letter and supporting documentation by Westinghouse on July 15, 2020 under LTR-RAC-20-62 listed in this document as reference Westinghouse 2020.
AECOM 2020a. 2019/2020 Annual Groundwater Monitoring Report, Columbia Fuel Fabrication Facility. Project number 60595649. (September 28, 2020).
EPA, 2012. U.S. Environmental Protection Agency, National Ambient Air Quality Standards (July 2012). (Accessed at http://www.epa.gov/air/criteria.html).
Eve, I. S. 1964. "Some Suggested Maximum Permissible Single Intakes of Uranium," Health Phys. 10(11).
Lott, 2000. Lott, N., S. McCown, and T. Ross. 1998-1999 Tornadoes and a Long-Term U.S.
Tornado Climatology, Technical Report No. 99-02. Asheville, North Carolina: National Climatic Data Center (2000).
WESTINGHOUSE NON-PROPRIETARY CLASS 3 to LTR-RAC-20-94 Date: December 18, 2020
Page7of11
Luessenhop, A. J., et al, 1958. "The Toxicity of Hexavalent Uranium Following Intravenous Administration," Am. J. Roentgenol 79, 83.
Mishima, J., L. Schwendiman, and Radasch, 1968. Plutonium Release Studies Release from Heated Plutonium Bearing Powers, BNWL-786, Pacific Northwest Laboratory, Richland, Washington.
Mishima, J., and L. Schwendiman, 1973. Fractional Airborne Release of Uranium (Representing Plutonium) During the Burning of Contaminated Wastes, BNWL-1730, Pacific Northwest Laboratory, Richland, Washington.
NAS (National Academy of Sciences), 1971. Fluorides, Committee on Biological Effects of Atmospheric Pollutants, Washington, D.C.
NCDC 2019. National Climatic Data Center, National Oceanic and Atmospheric Administration.
Online searchable database operated by the National Climatic Data Center (Ashville, NC),
which is part of the Department of Commerce, National Oceanic and Atmospheric Administration (NOAA), and the National Environmental Satellite, Data and Information Service (NESDIS).
The
- database, available at:
https://www.ncdc.noaa.gov/stormevents/choosedates.jsp?statefips=45%2CSOUTH+CAROL INA NCRP 2009. National Council on Radiation Protection & Measurements, Ionizing Radiation Exposure of the Population of the United States, NCRP Report 160 (2009).
NRC, 1975. U.S. Nuclear Regulatory Commission, Environmental Survey of Transportation of Radioactive Materials to and from Nuclear Power Plants, NUREG-75/038, Suppl. 1 (April, 1975).
NRC, 1977a. (U.S. Nuclear Regulatory Commission), Regulatory and Other Responsibilities as Related to Transportation Accidents, NUREG-0179, (June 1977).
NRC, 1977b. U.S. Nuclear Regulatory Commission, Final Environmental Statement on the Transportation of Radioactive Material by Air and Other Modes, NUREG-0170, vols. 1 and 2, (December 1977).
NRC, 1979. U.S. Nuclear Regulatory Commission, Assumptions Used for Evaluating the Potential Radiological Consequences of Accidental Nuclear Criticality in a Uranium Fuel Fabrication Plant, Regulatory Guide 3.34, Revision (July 1, 1979).
NRC 1981. U.S. Nuclear Regulatory Commission, "Uranium Fuel Licensing Branch Technical Position, Disposal or Onsite Storage of Thorium or Uranium Wastes from Past Operations,"
Fed. Reg. 146, p. 52061, (October 23, 1979).
NRC 1995. U.S. Nuclear Regulatory Commission, Environmental Assessment for Renewal of Westinghouse Electric Corporation License SNM-1107 (July 12, 1995).
NRC 2003. U.S. Nuclear Regulatory Commission, Environmental Review Guidance for Licensing Actions Associated with NMSS Programs, NUREG-1748 (August 2003).
WESTINGHOUSE NON-PROPRIETARY CLASS 3 to LTR-RAC-20-94 Date: December 18, 2020
Page8of11
NRC 2006. U.S. Nuclear Regulatory Commission, "NRC Request for Additional Information Regarding the Environmental Assessment for the Westinghouse CFFF Materials License SNM-1107 Renewal" (July 26, 2006).
NRC 2007a. U.S. Nuclear Regulatory Commission, NRC Environmental Assessment for Renewal of Special Material Nuclear Material License No. SNM-1107 (April 19, 2007).
NRC 2007b. U.S. Nuclear Regulatory Commission, Safety Evaluation Report for the Renewal of SNM-1107 Columbia Fuel Fabrication Facility in Columbia, South Carolina, ML072180276 (August 2007).
NUREG-1118. U.S. Nuclear Regulatory Commission, NRC Environmental Assessment for Renewal of Special Nuclear Material License No. SNM-1107, Docket (May 1985).
SCDHEC 2018. South Carolina Department of Health and Environmental Control, Statement of Basis (July 17, 2018).
SCDHEC 2019. South Carolina, Department of Health and Environmental Control, Bureau of Water, Watershed Water Quality Assessment, Saluda River Basin, Congaree River (03),
pages 146-155.
Available online at https://scdhec.gov/sites/default/files/docs/HomeAndEnvironment/Docs/Watershed/wwqa/Sal uda_WWQA_2011.pdf.
SCDHEC 2019a. South Carolina, Department of Health and Environmental Control, South Carolinas Nonattainment Areas.
https://www.scdhec.gov/environment/your-air/most-common-air-pollutants/south-carolinas-nonattainment-areas, accessed March 22, 2019.
SC-DNR 2011. DNR Geologic Survey, 2011. Geologic Map of the Fort Jackson South Geologic Quadrangle, Calhoun and Richland Counties, South Carolina, GQM-52, Kimberly M. Meitzen 2011.
SC-DNR 2019. A listing of State and Federal rare, threatened, and endangered species found in Richland Country, South Carolina, Department of Natural Resources.
SC-DNR 2019b. South Carolina County Weather Atlas, climate information from the South Carolina Department of Natural Resources, Office of State Climatology; available online at http://www.dnr.sc.gov/climate/sco/ClimateData/countyData/county_richland.php SC-DNR 2019c. South Carolina Hurricane Climatology. Climate information from the South Carolina Department of Natural Resources; available online at http://www.dnr.sc.gov/climate/sco/Tropics/hurricanes_affecting_sc.php.
Soil & Material Engineers, Inc., 1982, Ground-Water Hydrology of the Westinghouse Electric Corporation Plant, Richland County, South Carolina: Report No. H-8119, March 1, 1982.
USCB 2012a. U.S. Census Bureau, 2010 Census - Census Tract Reference Maps, South Carolina, Richland County (2012).
http://www2.census.gov/geo/maps/dc10map/tract/st45_sc/c45079_richland/
WESTINGHOUSE NON-PROPRIETARY CLASS 3 to LTR-RAC-20-94 Date: December 18, 2020
Page9of11
USCB 2012b. U.S. Census Bureau, 2012 Interactive Population Search(2012),
http://2010.census.gov/2010census/
USCB 2012c. U.S. Census Bureau, American Community Survey, Table DP-3, Selected Economic Characteristics, 2010 ACS 1-Year Estimates (2012).
http://factfinder2.census.gov/faces/nav/jsf/pages/searchresults.xhtml?refresh=t USCB 2012d. U.S. Census Bureau, American Community Survey, Table DP-3, Selected Economic Characteristics, 2008-2010 ACS 5-Year Estimates (2012).
http://factfinder2.census.gov/faces/nav/jsf/pages/searchresults.xhtml?refresh=t USGS 2008. U.S. Geological Survey, Interpolated Probabilistic Ground Motion For The Conterminous 48 States By Latitude Longitude, 2008 Data (2008).
http://earthquake.usgs.gov/hazards.
Westinghouse 1975. Westinghouse Electric Company, Westinghouse Nuclear Fuel Columbia Site Evaluation Report (March 1975).
Westinghouse 1983. Westinghouse Electric Company, SNM-1107 Update for Environmental Impact Appraisal (April 1983).
Westinghouse 2004. Westinghouse Electric Company, Environmental Report Update (December 2004).
Westinghouse 2006a. Westinghouse Electric Company, "Westinghouse License SNM-1107 Renewal Application Supplemental Environmental Report Information" (January 10, 2006).
Westinghouse 2006b. Westinghouse Electric Company, "Additional Information Requested for Environmental Assessment" (June 28, 2006)
Westinghouse 2006c. Westinghouse Electric Company, "Request for Additional Information Responses Regarding the Environmental Assessment Supporting SNM-1107 Renewal" (September 8, 2006)
Westinghouse 2008b. Westinghouse Electric Company, Integrated Safety Analysis of the CFFF Site and Structures (January 30, 2008).
Westinghouse 2011b. Westinghouse Electric Company, Columbia Plant ALARA Report, Calendar Year 2010 (November 2, 2011).
Westinghouse 2012c. Westinghouse Electric Company, NRC Semi-Annual Discharge Report, July - December 2011, LTR-RAC-12-22, (February 29, 2012).
Westinghouse, 2013. Westinghouse Electric Company, Columbia Plant ALARA Report, Calendar Year 2012 (November 12, 2013).
WESTINGHOUSE NON-PROPRIETARY CLASS 3 to LTR-RAC-20-94 Date: December 18, 2020
Page10of11
Westinghouse, 2014g. Westinghouse Electric Company, BMP and SPCC Plans: Hazardous Material Emergency Response and Best Management Practices Plan for Control of Toxic Substances, Hazardous Waste and Potential Oil Spills, Part B, Table B-1, (February 2015).
Westinghouse 2014m. Westinghouse Electric Company, Columbia Plant ALARA Report, Calendar Year 2014. (October 30, 2015).
Westinghouse 2016. Westinghouse Electric Company, Columbia Plant ALARA Report, Calendar Year 2016. (December 13, 2017).
Westinghouse 2017. Westinghouse Electric Company, LTR-RAC-17-43, NPDES Permit SC0001848 Application for Renewal. (September 29, 2017).
Westinghouse 2018. Westinghouse Electric Company, Columbia Plant ALARA Report, 4th Quarter 2018. (December 20, 2018).
Westinghouse 2018a. Westinghouse Electric Company, LTR-RAC-18-81, HF Spiking Station #2 Summary. (November 30, 2018).
Westinghouse 2018b. Westinghouse Electric Company, LTR-RAC-18-82, Contaminated Wastewater Summary. (November 30, 2018).
Westinghouse 2019a. Correspondence with Phil Simmons, Human Resources Director (March5, 2019).
Westinghouse 2019b. Westinghouse Electric Company, LTR-EHS-19-17, Assessment of Public Radiological Dose from Liquid and Gaseous Effluents for Calendar Year 2018 (February 22, 2019).
Westinghouse 2019c. Westinghouse Electric Company, "Summary of Gaseous and Liquid Effluent Discharges, (2003 through 2018).
Westinghouse 2019d. Westinghouse Electric Company, Integrated Safety Analysis of the CFFF Site and Structures, (January 2019).
Westinghouse 2019e. Westinghouse Electric Company, LTR-RAC-19-22, Westinghouse Responses To Request for Additional Information Regarding the Environmental Review For Renewal of the Columbia Fuel Fabrication Facility License, (March 28, 2019).
Westinghouse 2019f. Westinghouse Electric Company, Tier II Report for calendar year 2018 data, (February 28, 2019).
Westinghouse 2019g. Westinghouse Electric Company," Westinghouse CFFF Licenses, Permits and Certificates Tracking Sheet" (March 25, 2019).
Westinghouse 2019h. Westinghouse Electric Company, LTR-RAC-19-44, FINAL Remedial Investigation Work Plan Submission Cover Letter, (June 18, 2019).
WESTINGHOUSE NON-PROPRIETARY CLASS 3 to LTR-RAC-20-94 Date: December 18, 2020
Page11of11
Westinghouse 2020. Westinghouse Electric Company, LTR-RAC-20-62, Response to SCDHEC Letter dated May 4, 2020; Final Interim Remedial Investigation Data Summary Report. (July 15, 2020).
Please note that this document was the cover letter and supporting documentation for the submission of the AECOM Final Interim Remedial Investigation Data Summary Report listed in this document as reference AECOM 2020.