WESTINGHOUSE NON-PROPRIETARY CLASS 3 0 to LTR-RAC-20-94 Date: December 18, 2020 0

Response to Request for Additional Information May 2019 air permit renewal application Table 4 - Emission Calculations for Scrubber

Table 4 - Emission Calculations for Scrubbers

A B

C D

Source Pollutant Emission Rate from February 2019 Engineering Testing (lbs/hr)1 Conservatism Factor2 Hourly Emissions Including Conservatism Factor (lbs/hr)

Maximum Annual Emissions Including Conservatism Factor (tons/yr)

S-4025 Scrubber Antimony 3.15E-06 5

1.58E-05 6.90E-05 Arsenic 3.29E-06 5

1.65E-05 7.21E-05 Beryllium 7.23E-07 5

3.62E-06 1.58E-05 Cadmium 9.33E-05 5

4.67E-04 2.04E-03 Chromium 1.09E-05 5

5.45E-05 2.39E-04 Cobalt 2.98E-06 5

1.49E-05 6.53E-05 Manganese 1.90E-05 5

9.50E-05 4.16E-04 Nickel 1.43E-04 5

7.15E-04 3.13E-03 Phosphorus 5.32E-04 5

2.66E-03 1.17E-02 Selenium 6.26E-05 5

3.13E-04 1.37E-03 Hydrogen Fluoride 0.0093 5

0.0465 0.2037 Nitric Acid 0.0654 5

0.3270 1.4323 Hydrochloric Acid 0.0075 5

0.0375 0.1643 Sulfuric Acid 0.0285 5

0.1425 0.6242 Lead 1.13E-05 5

5.65E-05 2.47E-04 S-1030 Scrubber Hydrogen Fluoride 0.0020 5

0.0100 0.0438 Nitric Acid 0.0100 5

0.0500 0.2190 NOx 0.12 3

0.36 1.58 S-958 Scrubber Hydrogen Fluoride 0.0008 5

0.0040 0.0175 Nitric Acid 0.0374 5

0.1870 0.8191 NOx 1.76 2

3.52 15.42 S-1190 Scrubber Hydrogen Fluoride 0.0009 5

0.0045 0.0197 Nitric Acid 0.0022 5

0.0110 0.0482 S-2A/2B Scrubber Hydrogen Fluoride 0.0006 5

0.0030 0.0131 Nitric Acid 0.0014 5

0.0070 0.0307 S-1008 Scrubber Hydrogen Fluoride 0.0003 5

0.0015 0.0066 Nitric Acid 0.0009 5

0.0045 0.0197 Footnotes:

2 Allows for additional conservatism to account for the limited engineering test data set and potential process variation.

Example Calculations:

Table 4 - Emission Calculations for Scrubbers Westinghouse Electric Company LLC Hopkins, South Carolina 1 Please refer to Report on Engineering Evaluation Testing, CleanAir Project Number 13754, March 27, 2019. To provide conservatism in the emission calculations, this is the highest hourly rate from the three test runs (not the average hourly emission rate from the three runs).

prepared by GEL Engineering, LLC, May 30, 2019 A lbs hour from source test x B conservatism factor =

C lbs emissions hour including conservatism factor C lbs emissions hour including conservatism factor x 8760 hours0.101 days <br />2.433 hours <br />0.0145 weeks <br />0.00333 months <br /> year x 1 ton 2000 lbs =

D tons emissions year including conservatism factor