008ZO 11 2 3 4 5 6 7 8 9 10 NOTES REF A SIS AUTO 43/TS - TRANSFER SWITCH TRANSFERS CONTROL FROM 5&6 START SIGNAL MAIN CONTROL BOARD TO HOT SHUTDOWN PANEL 3HHB~F9J <LOCATED AT SWITCHGEAR).

REF B 4KV AUTO TRANSFER AMSAC 5&6 SIGNAL (NO SIS) STEAM GEN 43 - 11MODE SELECTOR SWITCH FOR SELECTING E LO-LO LEVEL CS/NEUT BLOWDOWN AUT0 11 OR 11 MANUAL 11 MODE (LOCATED AT HOT SHUTDOWN PANEL).

za:

~3

</)§~ I'-

STEAM GEN NO.

STEAM GEN NO. D TRANSFER TO DIESEL BLOCK AUTO START VALVES (REF 4)

STEAM GEN NO. 6 - REMOTE CONTROL SWITCH LOCATED ON HOT SHUTDOWN PANEL.

STEAM GEN NO.

SIS FCO CUTOUT C) 43/MAN 6.,REMOTEJ ALARM CS/NEUT CUT-IN CUT-OUT AUX FDW D z

0 6REMOTE SW (CB) SUP VLV t- CS/CLOSE (SWGR)

<lW

...Jo..r-;1- LCVI IO

.....J L::::,jLfl

<lt- 43/TS/CONTROL ROOM LCVI I I

(/)

z CS/START a LCV 113 CLOSE CS/START 52 TRIP b--0 LCV 115

<REF 3) 0 ALARM 52HH8 NO. 22 52HF9 NO. 23 212 1 - - ~

C t- CS/STOP z:::, ...

N 6REMOTE REFERENCES DWG NO.

I. LOGIC DIAG SYMBOLS _________ J9425 CS/STOP

2. SCHEM DIAG AUX FW pp _ _ _ _ _ _ _ _ 441302
3. SCHEM DIAG AUX FDW MTR OP VV ___ 441301 OVERCURRENT V)
4. SCHEM DIAG GEN BLOWDOWN SOL VV ___ 441461 REF C TRANSFER TO DIESEL Q_
5. LOGIC DIAG 4KV BUS 5&6 LOAD SHED wL i=  ::J SECTION II F11 AUTO TRANSFER _____ . 441286

~ 0....

c,;,

z

,q-I B 6, LOGIC DIAG 4KV BUS SECTION 11 H11 AUTO TRANSFER CS/TR IP ( SWGR) B

~

3

<l 0::

~ w B

NUCLEAR SAFETY RELATED f-

<(

REV REGISTERED ENGINEER SIGNATURE CA REG NO, EXP DATE

~ COAST VALLEYS DIVIS ION 0

w 102800D,E62 04-28-94 WAA KEY DWG--SECT[ON _ 3_ UNIT 2 MICROFILM -e WN LL BILL OF MATL I

I DWG LIST X

rz  :::::,

A ON OWN SUPSDS I-~.J >-

<( ~

REF 5 & 6 (FCT-16395) DWL JWC CHKD EZ DIABLO CANYON SUPSD BY A u

c.,w i.n I 9-30-75 APPROVED FOR CONSTRUCTION 169972 EZ LRW ON OK HH DPJ SHEET NO. SHEETS

~~ - DEPARTMENT OF ENGINEERING

, NO. DATE DES CR I PTI ON GM/SPEC OWN CHKD SUPV APVD BY TAB DATE 9-23-75 PACIFIC GAS AND ELECTRIC COMPANY REV 102800 8 V,

SCALES c,;,WGJ c,_

3~ s::r ! R E V I S I ONS NONE SAN FRANC[SCO, CAL[FORNIA Nl805 2 3 4 5 I 6 7 8 9 10