20 29 I

21 I

22 I

23 I

24 I

25 I

26 I

27 I

28 I

....,j..... _________

A B

C D

E LEGEND HVAC UNIQUE SYMBOLS (SEE DWG 108001 SHEET 3 FOR PIPING SYMBOLS)

-(Qr..

I

[I]

I CcNT.VrUOAl FAN CENWru:;At. rAN (WITH INLcT J/AN~S)

PUMP CO/o/lP/<ESSO/Q..

VANEAXIAl FAA/

PROPELLER OR TUBEAX/AL FAN HEATING COIL E -ELECTRIC S -STEAM

{ ELECTRIC SHOWN)

COOLING COIL W -

WATER DX - DIRECT EXPANSION CD-CONDENSER (WATER SHOWN)

/WUGHING FlllcA

( ~-F/c.Tcr:)

CIIAfiCOAt. F/lTEA lOtl//~

.DEMISTeR

( MOISTUR.c ScP-'1~0.R,,)

I 5

S r----------5 0

I I

I


i4V'v-

~

I I

SUPPLY AIR DUCT-CLASS JI &.1Il

{PIPING WHEN LINE NUMBER IS PRE.SENT)

SUPPLY AIR DUCT-CLASS I SAFETY RELATED VENTILATION SYSTEM.

eX/IAIAST O</ R_cR/P/'I A/~ OuCT-CLASS II & III. VENT/LA TION e)(HAU..5T OP. RcTI/N/ A/,R.. DUCT-CLASS I.

SAFETY fft.ATED f,,f,,./nlA710N SY57cM.

IMAGltVAr<V.8()(/#?,4,R_y' rOR_ SY5TcMS, Ft/Ttl.RE EQt 1/PMEA/T OU'Tt_ tNE, a,<.?_,P~OQ?SE.O Pt;OING l/NE.

Clt'4/vl'Sc Or ct.c#TION 04" t.Ei/cl,Aqa/cC77a,\\/

t:.IN'E i1/!Tfl CV<1<;-1N' e, nt=..5T/N,4T/ON' PROJECTION LINE (SE.£ PRECEDING)

CROSS

REFERENCES:

ALPHA CHARACTER c: RETURN AIR NUMERIC CHARACTER ::.SUPPLY AIR SUPPLY AIR DIFFUSER EXHAUST OR RETURN REGISTER eXHAI.JST Al.le? FLOW (r) r(.00~ 0~ (C) CEl{/N(r OPENING-E.G.

  • C+F MEANS OPENINGS BOTH ON CEILING AND ON FLOOR.

11WINDOW"OP£NING OR OPENING IN WALL ct.ECTNC OPc~-47-0,,~

(SOllO STATE)

Ptl/ct/MATIC O.PcMTO/<..

MANUAL OPY'-ATOR.

COU/VTEP.WEIGlfT I

I

--{X}-

===l/~ -/-........

5--@--:s

&/TTER..FlY J#JLt/c ~

,-0()5/T/YE SHUT-Orr D4\\,f~

D4MPERJ' (1N WAt.(. i:. IN L)VC71,,yc;.,

,'(_c Sl'ec71 vet. Y) 8ACI( LJRAFT D4MPcR.

Fl.RE OP. &WOKE D4MPER EXPANSION' ~

VE THERMOSTATIC Alf< VE/\\/1.

SIG-HT Ct.ASS CHARGING VALVE rt.OW ELEMENT (AI.R. MONITOA.;)

SMOKE DETECTO~

ANALYSIS SENSOR.

HJ/AC: 7cMPEl<ATt/N t;.HdMIOITY Pll°IN'Cr: CONDUCTIVITY et.EMENT I

I HVAC UNIQUE ABBREVIATIONS (SEE DWG. 108001 SHEET 3 FOR PIPING ABBREVIATIONS)

~-,"

B/J.f?! 800':__ l3ACK lY<ArT l).,/M~R.

C - _

COOllNG CO/t.

CH-_

CNTMT CP-_

.ox E-_

EFC-EFH--

EH-_

cXH.

FA.I.

F8---

FC-__

F.C.

FD-__

F. o.

FU- __

HVAC M-__

MD- __

MOD-__

0/A pp s-SD-_

Sa-_

SUP.

~

TV-_

CONTAINMNT COM PRE SSO/<-

CON Dc N'SE P.

LY/<cCT EXPANSION COIL EXHAUST FAN EXHAUST FILTER BANK EXHAUST FILTER CHARCOAL EXHAUST FILTER HEPA EXHAUST FILTER ROUGHING Et.ECTNC HEATER EXHAUST FAIL AS IS FILTER BANK FLEXIBLE CONNECTOR FAIL CLOSE FIRE DAMPER FAIL OPEN FILTER UNIT HEATING, VENTILATION,&, AIR CONDITIONING MODE DAMPER MANUAL DAMPER MOTOR OPERATED DAMPER OUTSIDE AIR SUPPc.Y F4N SMOKc.OAMPEP JIOHT G(.,4SS SUPPC.Y FIRE DAMPER OR SMOKE DAMPER UNIT 2 P. G. 8'E. CO.

DRAWING NU>eER SHEET2 OF SHEETS 108023 REV 36 RMS INDEXED REV ___

M_I_CR_O_F_I L_M ____

I I

A B

C D

E