e AT L ANT A. GIORGIA 30303 February 2,1681 MEMORANDUti FOR:
Chief, Vendor Insoection Branch, Reofon IV
.FROM:
Charles E. tiurphy, Chief, Reactor Construction and Engineering Support Branch, Region II
SUBJECT:
CONSTRUCTION DEFICIENCY REPORT - CONFIRMATION OF TELECON (AITS NO. F02500320 )
' Attached is a 10 CFR 50.55(e)/10 CFR 21 report received from Tennessee Valley Authority
. - This appears to be a generic problem.
Would you please. followup on the generic aspects of the problem with the AE/ Vendor.
-Should you have additional questions, we will be glad to discuss them with you.
m* /,,
m e (.,.,,,_
Charles E. tiurohy '
cc:
Princinal Staff, RII RC&ES Branch Chiefs, RI, III, IV, V G. 'lavne Reinmuth, ~IE CONTACT:
R. W. Wright (242-5578)
N,,
8612110310 061209 PDR FOIA ELLISS6-656 PDR
{
f 2~N
1 :(
DAILY REPORT --REGION II l February 2,1981 Ch *.
ITEM FACILITY-NOTIFICATION-ITEf1 OR EVENT-REG 10NAL' ACTION REACTOR CONSTRUCTION Hartsville A1, 81,. A2, B2 Telecon 1/39 CDR - Diesel Generator Turbocharaer Thrust
- Insoect per MC 2512)
ONS: 50-518 Bearinos. A notential' defect exists in the.
Reaion IV notified. -
50-519 lubricatinq oil system. that suoplies ~ oil to 51-520 the turbocharoer bearings. The defect 50-521 orevents oil flow to the bearings when the enoine is.in the standby mode. The-turbo-Phinos Bend 1, 2 charger thrust bearings may. experience ranid DNS: 50-553 wear because of the' unique ooerations of 50-554 nuclear standby engines..Transamerica,n -
DeLavel, Inc., reported this -as 1a Pirt 21 by letter to 0IE dated 12/16/80. The diesel turbocharger was ~ manufactured,by Elliot Co...
of Jeannette, Pennsylvania. A written reoort-is due.3/2/81.
.c O
=
0 GENERAL