Text
$
A.
EFFLUENT AND WASTE DISPOSAL REPORT This section contains a summary of the liquid and gaseous release limits; a listing of the maximum permissible concentrations of the isotopes released; a summary of batch and abnormal release data; a summary of total liquid and gaseous releases; listings of isotopes released classi-fled by pathway, gaseous or liquid, and type, continuous or batch; and a summary of solid radioactive waste shipments.
This section represents all releases during the period January 1, 1986 through June 30, 1986.
As per Technical Specification 3.3.3.11.b, the condenser air ejector flow rate measuring device (FR-3100) is reported as inoperable during the period January 1, 1986 through June 30, 1986. As reported in the March 21, 1986 letter to J. B. Martin of USNRC, Region V, this flow rate has been measured every shift using rotometers FI-3111 or FI-3184.
The repair and/or replacement of FR-3100 is being aggressively pursued with an expected completion date of June 30, 1987.
i l
8609160267 860630 PDR ADOCK 05000344 TF _. 6 R
pop
((
+
TABLE A-1 PART A-1 SUPPLEMENTAL INFORMATION January 1,1986 through June 30, 1986 REGULATORY LIMITS First Second Fission and Activation cas Release Rate Limits Unit Ouarter Quarter 1.
Instantaneous QTv g 1
C1/sec 2.42E-2 5.32E-2 2.0 Ky QTv $
1 Ci/sec 8.17E-2 1.66E-1 0.33 (Ly + 1.1 N )
y 2.
Tech Spec 3.11.2.2, Quarterly Average Ci/sec 9.17E-4 1.96E-3 QTv i 1
50 Ny C1/sec 2.13E-3 2.94E-3 QTV g 1
25 My 3.
Tech Spec 3.11.2.4(1), Quarterly Average Requiring Use of the caseous Radwaste Treatment System Ci/sec 4.59E-4 9.80E-4 QTv g 1
100 Ny Ci/see 1.06E-3 1.47E-3 QTV i 1
50 My 0008b A-2
o TABLE A-2 PART A-2 SUPPLEMENTAL INFORMATION January 1, 1986 through June 30, 1986 REGULATORY LTMITS Caseous Iodine 131. Tritium. and Particulates First Second Unit Ouarter Quarter With > 8 day T1/2 Limits 1.
Tech Spec 3.11.2.1(b). Instantaneous QTv s 1
C1/sec 9.82E-3 3.62E-3
.67 Ri 2.
Tech Spec 3.11.2.3, Quarterly Average Ci/sec 6.58E-5 2.43E-5 QTv s 1
100 Ri 3.
Tech Spec 3.11.2.4(2), Quarterly Average Requiring Use of the Caseous Radwaste Treatment System Ci/sec 3.29E-5 1.21E-5 QTv i 1
200 Ri 4
l I
A-3 l
TABLE A-3 PART A-3 SUPPLEMENTAL INFORMATION January 1, 1986 through June 30, 1986 REGULATORY LIMITS Liould Effluent Limits 1.
Tech Spec 3.11.1.1 Instantaneous discharge concentrations Instantaneous less than the maximum permissible concentrations listed in 10 CFR Part
- 20. Appendix B, Table II, Column 2, for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration is limited to 2 x 10-4 pCi/ml total activity.
2.
Tech Spec 3.11.1.2 Gross release limit of 2.5 Ci per Quarterly Average quarter excluding tritium and dissolved noble gases. If this limit is exceeded, cumulative dose due to liquid effluents will be limited to 1.5 mrem to the whole body and to 2.5 mrem to any organ, using isotope specific methodology in the plant offsite dose calculation manual (ODCM).
3.
Tech Spec 3.11.1.3, The liquid radwaste treatment system Quarterly Average Requiring shall be maintained and used when i
Use of the Liquid Radwaste activity discharged (excluding tritium Treatment System and dissolved noble gas) would exceed 1.25 Ci/Qtr.
l 4.
Tech Spec 3.11.1.4 The quantity of radioactive material Temporary Storage Tank contained in temporary radwaste storage Activity Limit tanks is limited to s 10 Ci excluding tritium and dissolved noble gases, t
A-4
~ -
TABLE A-4 PART A-4 SUPPLEMENTAL INFORMATION January 1, 1986 through June 30, 1986 MAXIMUM PERMISSIBLE CONCENTRATIONS Liould MPC MPC Isotope (uci/ce)
Isotope (uci/cc)
Fluorine 18 8 x 10-4 Iodine 131 3 x 10-7 Chromium 51 2 x 10-3 Iodine 132 8 x 10-6 Manganese 54 1 x 10-4 Tellurium 132 2 x 10-5 Iron 55 8 x 10-4 Iodine 133 1 x 10-6 Cobalt 57 4 x 10-4 Cesium 134 9 x 10-6 Cobalt 58 9 x 10-5 Cesium 137 2 x 10-5 Iron 59 5 x 10-5 Cesium 138 3 x 10-6 Cobalt 60 3 x 10-5 Barium 140 2 x 10-5 Rubidium 88 3 x 10-6 Lanthanum 140 2 x 10-5 Strontium 89 3 x 10-6 Cerium 141 9 x 10-5 Strontium 90 3 x 10-7 Cerium 144 1 x 10-5 Zirconium 95 6 x 10-5 Alpha 3 x 10-8 Niobium 95 1 x 10-4 Unidentified 3 x 10-8 Molybdenum 99 4 x 10-5 Tritium 3 x 10-3 Technetium 99m 3 x 10-3 Krypton 85m 2 x 10-4 Ruthenium 103 8 x 10-5 Krypton 87 2 x 10-4 Ruthenium 106 1 x 10-5 Krypton 88 2 x 10-4 Silver 110m 3 x 10-5 Xenon 131m 2 x 10-4 Tin 113 8 x 10-5 Xenon 133 2 x 10-4 Antimony 124 2 x 10-5 Xenon 133m 2 x 10-4 Antimony 125 1 x 10-4 Xenon 135 2 x 10-4 Kenon 135m 2 x 10-4 Caseous Caseous MPCs are not used in calculating technical specifications at Trojan.
A-5
TABLE A-5 PART A-5 SUPPLEMENTAL INFORMATION January 1, 1986 through June 30, 1986 AVERAGE ENERGY Effluent release limits are not based upon E, hence, reporting E is not required.
MEASUREMENTS AND APPROKIMATIONS OF TOTAL RADIOACTIVITY Caseous Releases Fission and Activation Cases: Gamma spectrometric analysis of gaseous grab samples define radionuclide distribution at least monthly on monitored gaseous release points. Using the known nuclide distributions and process radiation monitor readings, the actual quantities of gaseous releases are calculated.
Iodines: Weekly composite filter and iodine cartridge samples are analyzed by gamma spectroscopy to determine the concentration of particulate and iodine isotopes. Weekly composite samples are analyzed for beta and alpha emitting isotopes by counting with a gas flow proportional counter. Quarterly composite filters are analyzed for Sr-89/90 using gas proportional beta counting and chemical separation techniques when necessary.
l Tritium: Tritium is collected on dry silica gel in monthly composite samples and counted using liquid scintillation spectroscopy.
Liquid Releases Fission and Activation Products: Gamma spectrometric analysis of each batch is performed. Weekly composite samples are maintained for continuous releases, and the composites are analyzed for specific nuclides as required. Monthly and quarterly composites are prepared for both batch and continuous releases for specified activity determinations.
Tritium: Monthly composite samples are distilled and deionized as necer,sary to remove contamination and counted by liquid scintillation techniques.
f Dissolved and Entrained Cases: Gaseous isotopes are determined by r
gamma spectrometric analysis of each batch and on a minimum frequency of once per month for continuous releases.
A-6 l
t TABLE A-6 PART A-6 SUPPLEMENTAL INFORMATION January 1,1986 through June 30, 1986 BATCH FELEASES Unit Liquid Caseous 66 101 Number of Batch Releases Hours 291.4 1859 Total time period for Batch Releases Hours 25.4 108.8 Maximum time period for Batch Releases Hours 4.4 18.4 Average time period for Batch Releases Hours 0.3 0.3 Minimum time period for Batch Releases CPM 29180 NA Average dilution flow during Batch Releases ABNORHAL RLEASES 1
2 Number of Abnormal Releases C1 1.17E-5 3.19E0 Total Activity Released l
l l
l A-7
4 TABLE A-7 Sheet 1 of 2 PART B-1 CASEOUS EFFLUENTS SUMMATION OF ALL RELEASES January 1, 1986 through June 30, 1986 First Second Estimated FISSION AND ACTIVATION CASES Unit Ouarter Ouarter Error %
Total Activity Released Ci 4.75E+2 2.46E+2 13.5El Average Release Rate for Quarter pC1/sec 6.12E+1 3.14E+1 Percent of Limit:
4.35E-1 3.08E-1 Tech. Spec. 3.11.2.1 (a) -
Instantaneous 6.65E0 1.60E0 Tech Spec. 3.11.2.2 -
Quarterly Average Tech. Spec. 3.11.2.4.(1) -
1.33E+1 3.19E0 Quarterly Average Requiring Processing IODINE 131 Total Iodine 131 Released C1 1.76E-4 3.80E-3 13.5El Average Release Rate for Quarter pCi/sec 2.27E-5 4.84E-4 PARTICULATES Total with Half-lives > 8 days C1 3.91E-5 2.46E-4 13.5El Average Release Rate for Quarter pCi/sec 5.04E-6 3.14E-5 Total Cross Alpha Released Ci 7.52E-6 1.08E-6 i
TRITIUM C1 1.68E0 1.47E+1 13.0E1 Total Released l
Average Release Rate for Quarter pCi/see 2.17E-1 1.87E0 A-8
TABLE A-7 Sheet 2 of 2 IODINE 131, PARTICULATES WITH First Second Estimated
> 8 DAY T1/2 AND TRITIUM Unit Quarter Quarter Error %
Total Released C1 1.68E0 1.47E+1 13.5El Average Release Rate for Quarter pC1/sec 2.17E-1 1.87E0 Percent of Limit:
4.89E-3 1.88E-1 Tech. Spec. 3.11.2.1 (b)
Instantaneous 3.30E-1 7.70E0 Tech. Spec. 3.11.2.3 Quarterly Average Tech. Spec. 3.11.2.4(2) 6.60E-1 1.54E+1 Quarterly Average Requiring Processing A-9
1 4
TABLE A-8 Sheet I of 2 PART B-2 GASEOUS EFFLUENTS GROUND LEVEL RELEASES January 1, 1986 through June 30, 1986 NUCT,TDES RELEASED Continuous Mode Batch Mode Unit 1st Quarter 2nd Ouarter 1st Ouarter 2nd Quarter FISSION CASES Krypton 85m Ci 8.67EO 1.70E0 4.128-1 1.49E-2 9.15E-1 3.49E0 Krypton 85 C1 Krypton 87 C1 1.32E+1 2.32E0 1.01E-2 7.13E-3 Krypton 88 C1 1.90E+1 3.39E0 3.81E-2 1.77E-2 Krypton 89 Ci 1.37E0 2.34E0 Xenon 131m C1 Kenon 133m C1 1.85E0 4.18E-1 9.80E-1 7.20E-1 Xenon 133 C1 1.53E+2 7.19E+1 9.71E+1 1.18E+2 Xenon 135m Ci 6.14E+1 1.13E+1 2.21E-2 1.10E-2 Kenon 135 Ci 8.00E+1 2.20E+1 2.11E0 6.97E-1 Kenon 137 Ci 6.22E0 1.07E0 Xenon 138 C1 2.74E+1 5.03E0 ArEon 41 C1 1.04E0 1.52E-1 2.312-1 3.89E-2 TOTAL FOR QUARTER C1 3.72E+2 1.19E+2 1.03E+2 1.25E+2 A-10
i TABLE A-8 Sheet 2 of 2 Continuous Mode Batch Mode Unit 1st Ouarter 2nd Ouarter 1st Ouarter 2nd Ouarter IODINES Iodine 131 C1 1.65E-4 4.04E-4 1.08E-5 3.40E-3 Iodine 132 Ci 1.86E-6 1.45E-7 5.60E-8 2.85E-5 Iodine 133 Ci 6.83E-5 1.60E-5 5.43E-6 1.16E-4 Iodine 134 Ci 3.36E-7 1.08E-8 Iodine 135 C1 1.49E-5 6.94E-7 6.68E-7 4.60E-5 TOTAL FOR QUARTER Ci 2.50E-4 4.21E-4 1.70E-5 3.59E-3 ffA,RTICULATES > 8 DAY T-1/2
{
Strontium 89 Ci 2.49E-5 6.55E-5 ND 1.02E-4 Strontium 90 Ci 8.07E-8 7.05E-7 ND 5.42E-5 Cesium 137 Ci 6.48E-8 2.97E-6 1.34E-8 5.28E-6 Cobalt 58 C1 1.13E-5 1.23E-5 3.16E-8 2.59E-6 l
Cobalt 60 C1 Ruthenium 103 Ci 3.17E-8 Niobium 95 2.73E-6 2.42E-7 l
TOTAL FOR QUARTER Ci 3.91E-5 8.17E-5 4.50E-8 1.64E-4 I
l l
A-ll 1
\\
e
~
TABLE A-9 PART B-3 GASEOUS EFFLUENTS ELEVATED RELEASES January 1, 1986 through June 30, 1986 No Elevated Release Points i
I 4
I l
1 l
l l
l A-12 i
i
TABLE A-10 PART C-1 LIQUID EFFLUENTS SUMMATION OF ALL RELEASES January 1, 1986 through June 30, 1986 FISSION AND ACTIVATION PRODUCTS First Second Estimated Unit Quarter Quarter Error %
Total Activity Released (excluding C1 4.60E-2 8.47E-2 13.5E+1 gases, tritium, and alpha)
Average Diluted Concentration pCi/mi 3.24E-9 5.43E-9 Percent of Limit Tech Spec 3.11.1.1 - Instantaneous 9.79E-1 1.57E0 Tech Spec 3.11.1.2 - Quarterly Limit 1.84E0 3.39EO Tech Spec 3.11.1.3 - Quarterly Limit 3.67E0 6.78E0 Requiring Processing TRITIUM Total Released C1 1.17E+2 8.59E+1 13.0E+1 Average Diluted Concentration pCi/mi 8.24E-6 5.51E-6 2.75E-1 1.84E-1 Fraction of MPC DISSOLVED AND ENTRAINED CASES Total Activity Released Ci 4.02E-2 2.88E-2 13.5E+1 Average Diluted concentration pCi/mi 2.83E-9 1.85E-9 1.42E-3 9.23E-4 I
Fraction of MPC GROSS ALPHA RADIOACTIVITY Total Activity Released C1 ND 3.11E-5 13.0E+1 UNDILUTED VOLUME OF WASTE RELEASED Liters 1.14E+7 1.13E+7 15.0E0 VOLUME OF DILUTION WATER Liters 1.42E+10 1.56E+10 11.5E+1 A-13
- )
s TABLE A-11 Sheet 1 of 2 PART C-2 LIQUID EFFULENTS January 1, 1986 through June 30, 1986 NUCLIDES RELEASED Continuous Mode Batch Mode M
1st Ouarter 2nd Quarter 1st Ouarter 2nd Quarter Fluorine 18 Ci 6.49E-6 3.40E-6 5.81E-3 Chromium 51 Ci Manganese 54 C1 2.87E-4 6.29E-4 Iron 55 Ci ND ND 5.53E-3 4.08E-3 7.93E-6 Cobalt 57 Ci Cobalt 58 Ci 5.77E-3 5.30E-4 2.60E-2 2.45E-4 Iron 59 C1 Cobalt 60 C1 4.77E-4 1.01E-2 6.82E-3 1
5.48E-6 Rubidium 88 Ci Strontium 89 C1 1.40E-4 3.67E-4 3.81E-5 5.12E-4 I
Strontium 90 Ci 4.22E-5 7.41E-5 1.55E-6 1.07E-4 1.09E-3 Zirconium 95 C1 1.85E-3 Niobium 95 C1 2.44E-5 Molybdenum 99 Ci 2.60E-5 Technetium 99m C1 1.11E-3 Ruthenium 103 Ci 2.65E-3 2.29E-3 Ruthenium 106 C1 9.15E-5 1.49E-4 Silver 110m Ci 2.63E-5 Tin 113 Ci 1.40E-3 Antimony 124 Ci 7.86E-4 6.62E-3 Antimony 125 Ci Iodine 131 Ci 2.33E-3 4.85E-3 4.84E-4 4.45E-4 1.04E-5 Iodine 132 Ci 3.57E-5 Tellurium 132 Ci A-14
.]
3 4
TABLE A-11 Sheet 2 of 2 NUCLTDES RELEASED Continuous Mode Batch Mode Unit 1st Ouarter 2nd Quarter 1st Ouarter 2nd Ouarter Iodine 133 C1 2.19E-3 2.35E-4 1.16E-4 1.58E-5 Cesium 134 C1 1.53E-5 1.48E-4 7.51E-3 3.89E-3 Cesium 137 Ci 5.14E-5 3.07E-4 1.11E-2 5.93E-3 Cesium 138 Ci 3.29E-6 Barium 140 Ci 4.39E-4 Lanthanum 140 Ci 6.70E-4 4.19E-4 1.33E-3 Cerium 141 Ci 4.40E-5 Cerium 144 Ci 7.09E-4 3.31E-4 Unidentified Ci 8.26E-4 5.59E-4 TOTAL FOR QUARTER Ci 4.77E-3 1.29E-2 4.12E-2 7.19E-2 Krypton 85m C1 2.23E-7 Kenon 131m Ci 2.37E-4 9.73E-5 Xenon 133 Ci 4.11E-4 3.82E-2 2.79E-2 Xenon 133m Ci 2.60E-4 3.57E-4 Xenon 135 C1 1.29E-4 9.92E-4 4.53E-4 1.30E-6 Kenon 135m Ci i
TOTAL FOR QUARTER Ci 5.40E-4 ND 3.97E-2 2.88E-2 A-15
TABLE A-12 Shoot 1 of 2 Part D SOLID WASTE AND IRRADIATED RIEL SHIPMENTS January 1, 1986 through June 30, 1986 Activity Volume Estimate SOLID WASTE SHIPPED OFFISTE FOR BURIAL OR DISPOSAL During During Total (Not Irradiated Fuel) - Type of Waste 6 Months 6 Months Error %
4.969 Ci 61.24 m3 25%
- 1. Spent Resin, Filter Sludges, Evaporator Bottoms, etc.
6.067 Ci 92.79 m3 25%
- 2. Dry Compressible Waste, Contaminated Equipment, etc.
0 0
- 3. Irradiated Components, Control Rods, etc.
0 0
- 4. Other ESTIMATE OF MAJOR NUCLIDE DISTRIBUTION BY TYPE OF WASTE Nuclide
- 1. See attached sheet.
- 2. See attached sheet.
3.
4.
SOLID UASTE DISPOSITION Number of Shipments Mode of Transportation Destination 10 Exclusive Truck U.S. Ecology, Inc.
P.O. Box 638 Richland, L'A 99352 IRRADIATED FUEL SHIPMENTS DISPOSITION Mode of Transportation Destination Number of Shipments N/A N/A 0
A-16
TAELE A-12 page 2 of 2 ESTIMATE OF MAJOR NUCLIDE DISTRIBUTION BY TYPE OF WASTE 1.
Nuclide Ci Nuclide Ci H-3 0.856 Ru-103 0.001 C-14 0.100 Ru-106 0.054 Cr-51 0.001 Ag-110m 0.001 Mn-54 0.050 Sb-125 0.014 Fe-55 0.478 I-131 0.300 Co-58 0.818 Cs-134 0.459 Co-60 0.605 Cs-136 0.002 Ni-63 0.302 Cs-137 0.768 Sr-89 0.040 Ba-140 0.036 Sr-90 0.046 Ce-144 0.019 Eb-95 0.002 Pu-241 0.015 Zr-95 0.002 TOTAL 4.969 2.
Nuclide Ci
'Nuclide Ci H-3 0.330 Nb-95 0.283 C-14 0.008 Zr-95 0.221 Cr-51 0.517 Ru-103 0.078 Mn-54 0.063 Ru-106 0.213 Fe-55 1.387 Sn-113 0.002 Co-57 0.032 Sb-125 0.116 Co-58 0.903 Cs-134 0.093 f
Fe-59 0.002 Cs-137 0.170 Co-60 0.933 Ce-141 0.008 Ni-63 0.471 Ce-144 0.139 Sr-89 0.025 Pu-241 0.020 Sr-90 0.053 TOTAL 6.067 A-17
B.
OFFSITE RADIATION DOSES Offsite radiation doses from gaseous and liquid effluents for the first and second quarters of 1986 are presented in this section.
Included are quarterly doses to individuals at locations of maximum actual exposure and quarterly doses to the 50-mile population.
Doses are presented separately for batch and continuous releases and for noble gas, gaseous iodine and particulate, and liquid effluents.
Exposure locations are based on the land-use survey presented in the Updated FSAR and the 1985 annual survey of agricultural production.
Models and assumptions used in performing the dose analyses for 1986 are presented in Sections 11.2 and 11.3 of the Trojan Updated FSAR.
I I
l t
TABLE B-1 Sheet 1 of 2 PARAMETERS USED IN CALCULATING DOSES FROM CASEOUS EFFLUENTS (First Half 1986)
Value Parameter j
Accumulation and Decay Times (days) 1.0 Harvest of leafy vegetables to consumption by man 0.0 Harvest of pasture grass to consumption by animals 90.0 Harvest of stored feed to consumption by animals 60.0 Harvest of produce to consumption by man 20.0 Animal butchering to consumption 2.0 Food ingestion by animal to allking 7,300.0 Accumulation time on ground Human Consumption Rates (kg/yr) 64.0 Leafy vegetables by adult 456.0 Produce by adult 110.0 Heat by adult 310.0 Milk by adult 330.0 Hilk by infant 3
Breathing Rates (m /yr) 8,000.0 Adult 1,400.0 Infant Animal Consumption Rates (kg/ day) 50.0 Animal feed by mest animal 50.0 Animal feed by milk cow 6.0 Animal feed by milk goat Exposure Periods During Crowing Season (days) 60.0 Leafy vegetables 30.0 Pasture vegetation 60.0 Produce 0.7 Residential Structure Shielding Factor 0.2 Fraction of Particulates Initially Deposited on Leafy Vegetation 0.2 Fraction of Particulates Initially Deposited on Produce 1.0 Fraction of Iodine Deposited on Leafy Vegetation 1.0 Fraction of Iodine Deposited on Produce 2
240.0 Surface Density of Soil for Root Zone (kg/m )
14.0 Field Decay Half Life (days)
B-2 i
TABLE B-1 sheet 2 of 2 Value Parameter 2
Agricultural Productivity (kg/m )
2.0 Leafy vegetables 0.7 Pasture grass 2.0 Produce 7.300.0 Period of Long-Term Buildup for Activity in Soil (days) 1.0 Fraction of Leafy Vegetables Grown in Garden of Interest 0.76 Fraction of Produce Grown in Garden of Interest 0.5 Fraction of Year Animal Grazes on Pasture 1.0 Fraction of Daily Feed that is Pasture Grass when Animal Crazes B-3
s TABLE B-2 Sheet 1 of 2 PARAMETERS USED IN CALCULATING DOSES FROM LIQUID EFFLUENTS value let Otr. 1986 2nd Otr. 1986 Parameter 28,900.0 31,500.0 Plant Dilution Flow Rate (spm) 299,702.0 423,006.1 Columbia River Flow Rate (cfs)
Dilution Factors 2,219.0 6,428.0 Drinking water 488.0 1,414.0 Swimming water 488.0 1,414.0 Aquatic biota 488.0 1,414.0 Shoreline sediment 2,219.0 6,428.0 Irrigation water 2,219.0 6,428.0 Milk and meat animal water Decay Times (days) 0.62 0.58 Discharge to drinking water 0.0 0.0 Discharge to swimming water 1.0 1.0 Discharge to aquatic biota consumption 0.0 0.0 Discharge to deposition on shoreline sediment 0.62 0.58 Discharge to irrigation water withdrawal 0.62 0.58 Discharge to milk and meat animal water withdrawal 1.0 Leafy vegetable harvest to consumption by man 60.0 Produce harvest to consumption by man 90.0 Stored feed harvest to consumption by animals 0.0 Pasture grass to consumption by animals 20.0 Animal butchering to consumption 2.0 Food and water ingestion by cow / goat to milking Accumulation Times (days) 7,300.0 Shoreline sediment 7,300.0 Irrigated soil 60.0 Irrigated vegetables 30.0 Pasture grass Adult Consumption Rates (kg/yr) 730.0 Drinking water 21.0 Fish 5.0 Invertebrates (crayfish) 64.0 Irrigated leafy vegetables 456.0 Irrigated produce 310.0 Cow's milk from irrigated pastureland 310.0 Coat's n. ilk from irrigated pastureland 110.0 Meat from irrigated pastureland B-4 i
(
TABLE B-2 Sheet 2 of 2
(
Value 1st Otr. 1986 2nd Otr. 1986 Parameter 4.
Annual Exposure Times (hr/yr) 12.0 Swimming and boating 12.0 Shoreline activities 2,190.0 Irrigated pasture Infant Consumption Rates (kg/yr) 330.0 Drinking water 330.0 Cow's milk from irrigated pastureland 0.5 Fraction of Year Animals Graze on Pasture 0.5 Fraction of Year Crops are Irrigated 14.0 Field (Weathering) Half-Life (days) 2 0.104 Irrigation Rate (liters /m -hr) 0.2 Fractional Concentration of Water in Soil (g/s) 1.0 Fraction of Leafy Vegetables Grown in Garden of Interest 0.76 Fraction of Produce Grown in Garden of Interest 2.5 Irrigated Soil Self-Shielding Factor 0.25 Fraction of Isotope in Irrigation Water That is.
Initially Retained by Leafy Vegetables 0.25 Fraction of Isotope in Irrigation Water That is Initially Retained by Produce 0.7 Pasture Grass Yield (kg/m2) 2.0 Vegetable Yield (kg/m2) 240.0 Surface Density of soil (kg/m2)
Animal Consumption Rates (kg/ day) 60.0 Water by milk cow 8.0 Water by milk goat 50.0 Water by beef 50.0 Pasture vegetation by milk cow 6.0 Pasture vegetation by milk goat 50.0 Pasture vegetation by beef B-5
TABLE B-3 0 1 QUARTER 1986 DOSES FROM L7 QUID EFFLLTNTS (MREM)
-====
0THER TOTAL ADULT INFANT INTERNAL EXPOSURE PATNWAY BODY SKIN LUNG BONE THYROID THYROID ORGANS AQUATIC AT MAXIMUM LOCATION DRINKING WATER 3.9E-05 3.9E-05 3.5E-05 3.9E-05 5.4E-05 9.8E-05 3.7E-05 FISH CONSUMPTION 1.2E-03 1.2E-03 1.9E-04 9.8E-04 1.2E-03 0.0 4.5E-05 INVERTE2 RATE CONSUMPTION
~1.5E-04 1.5E-04 2.8E-05 1.3E-#
1.5E-04 0.0 6.9E-05 EXPOSURE TO SHO!!ELINE SEDItTENT 2.3E-06 2.7E-06 2.3E*06
~2.3E-06 2.JE-06 0.0 2.3E-06 SWIMMING AND BnATING 2.1E-08 1.5E-07 2.1E-08 2.1E-08 2.1E-08 0.0 2.1E-08 ACUATIC TOTAL 1.4E-U3 1.4E-03 2.6E-04 1.1E-03 1.5E-C3 9.8E-05 1.5E-04
.. _--____-_..__._--__.-. _____. _.---- _- - _-__ _--_-__ ____._.._ _.__--_m. _._--.._....._--_-. ____ _________
AQ'UATIC AT AGRIEULTURAL LOCATTON
__._-__a_._.--_.-_-_-__-_.
y DRINKING WATER 3.9E-C5 3,9E-05 3.5E-05 3.7E-05 5.4E-95 9.CE*05 3.7E-05
+
e FISH CONSUMPTION 2.7E-04 2.7E-04 4.2C-05 2.2E-04 2.6T-04 0.0 1.0E-05 INVERTEBRATE CONSUMPTION-3.3E-05 3.3E-05 6.1E-06 2.8E-05 3.4E-OS 0.0 1.5E-05 EXPOSURE TO SHORELINE SEDIMENT 5.1E-07 6.0E-07 5.1 E-C l 5.1E-07 5 10-07 0.0 5.1E-07 SWINNING ANP BOATING 4.7E-09 3.2E-08 4.7E-0(i 4.7E-09 4.7E-0) 0.0 4.7E-09 IliRIGATION AND LIVESTOCK WATLTING EXPOSURE TO AGRICULTURAL SOIL 6.7E-06 7.9E-06 6.7E-05 6.7E-06 6.7E-06 0.0 6.7E-06 LEAFY VEGETABLE CONSUMPTION 5.65-06 5.6E-06 3.5E-06 5.6E-06 1.7E-05 0.0 4.5E-06 PRODUCE CONSUMPTION
- 7. 8E-05 2.BE-05 1.8E-n5 2.BC-05 2.8E-05 0.0 2.2E-05 MEAT CONSUMPTION 8,4E-06 S.4E-06 8.7E-06 8.9E-05 9.2E-06 0.0 5.9E-05 MILK CONSUNPTION (COW) 3.3E-05 3.3E-05 1.8E-05 3.0E-05 5.6E-05 2.3E-04 1.7E-05 MILK CONSUMPTIOM (GDAT) 8.7E-05 8.7E-05 4.2E-05 7.7E-C5 1.1E-04 3.5E-04 3.5E-05 ACRTCUI;TURAL TOTAL EXCl.UDING COW MILK CONSUMPi10N 4.8E-D4 4.8E-04 1.6E-04 4.1E-04 5.4E -04 4.4E-04 1.9E-04 EXCl.UDIhG GOAT MILK CONSUMPTION 4.2E-04 4.2E-04 1.4E-C4 3.6E-04 4.8E-04 3.3E-04 1.7E-04 i'
,.. _ _ _ _ - _ - - _ _. _ _ _ _ _ _ _ - - - - _ - - - - _ - - - - - - - - - - - - - - ~ - - - * * - - - - - * - - - - ~ - * * " ' " ~ ~ ~ ' - - - " -
~ _____-____ -_____.-_--
- e W
a
TABLE B 4 FIRST QUARTER 1986 POPULATION DOSE (50-MILE) FROM LIQUID EFFLUENTS (MAN-REM)
=---- _.
=--
TOTAL EXPOSURE PATNWAY BODY THYROID AQUATIC 1.5E-04 2.2E-04 DRINKING WATER 1.2E-01 1.2E-01 FISH CONSUMPTION INVERTEBRATE CONSUMPTION 6.6E-05 6.7E-05 EXPOSURE TO CONTAMINATED SEDIMENT 1.1E-05 1.1E-05 SWIMMING AND BOATING 5.4E-08 5.4E-08 i
IRRIGATION AND LIVESTOCK WATERING LEAFY VEGETABLE CONSUMPTION 4.3E-07 1.3E-06 PRODUCE CONSUMPTION 2.1E-06 2.2E-06 1.2C-05 1.3E-05 MEAT CONSUMPTION 1.7E-04 3.0E-04 MILK CONSUMPTION EXPOSURE TO CONTAMINATED SOIL 9.7E-07 9.7E-07 1.2E-01 1.2E-01 TOTAL 5.7E-05 5.8E-05 AVERAGE DOSE (MREM / PERSON)
--_- -- - -=.-
8
TABLE B-5 FIRST QUARTER 1986 BATCH RELEASES DOSES FROM NOBLE GASES AT SITE BOUNDARY AND RESIDENCE OF HIGHEST CONCENTRATION Site Boundary [a]
Residence (b) 4.3E-2 2.3E-2 Beta Air Dose (mrad) 1.6E-2 6.0E-3 Gamma Air Dose (mrad)
Beta + Gamma Skin Dose (mrem) 1.4E-2 Gamma Total Body Dose (mrem) 5.1E-3
[a] East sector at 677 meters.
[b] East sector at 1000 meters.
i B-8 l
TABLE B-6 FIRST QUARTER 1986 CONTINUOUS RELEASES DOSES FROM NOBLE GASES AT SITE BOUNDARY AND RESIDENCE OF HIGHEST CONCENTRATION Site Boundary [a]
Residence [b]
Beta Air Dose (mead) 3.4E-1 1.8E-1 Gamma Air Dose (mrad) 4.4E-1 1.6E-1 Beta + Gamma Skin Dose (mrem) 3.2E-1 Gamma Total Body Dose (mrem) 1.SE-1
[a] North sector at 663 meters.
(b) North sector at 1000 meters, i
i l
B-9
TABLE B-7 FIRST QUARTER 1986 BATCH + CONTINUOUS RELEASES DOSES FROM NOBLE GASES AT SITE BOUNDARY AND RESIDENCE OF HIGHEST CONCENTRATION Site Boundary [a]
ResidenceID}
3.8E-1 2.0E-1 Beta Air Dose (mrad)
Gamma Air Dose (mrad) 4.6E-1 1.7E-1 Beta + Gamma Skin Dose (mrem) 3.3E-1 1.6E-1 Gamma Total Body Dose (mrem) la] Maximum site boundary location.
[b] Maximum residence location.
i l
l B-10
TABLE B-8 l
81 QUARTER 1986 BATCH RELEASES DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
_== - -
_ __ _ -=-----------------
.=-
= =---------------------
4 OTHER
_--=-- __
ADULT INFANT INTERNAL TOTAL EXPOSURE LOCATION AND PATHWAY BODY SEIN LUNG BONE THYROID THYROID ORGANS
=. _=- =-
_ = - - = - = -
l GARDEN (NNW SECTOR AT 1000. METERS)
AIR INHALATION 8.21E-06 8.21E-06 8.21E-06 8.22E-06 3.40E-05 3.73E-05 8.25E-06
_ - ---==--=
i EXPOSURE TO SOIL 4.67E-07 5.56E-07 4.67E-07 4.67E-07 4.67E-07 4.67E-07 4.67E-07 i
LEAFY VEGETABLE CONSUMPTION 2.71E-06 2.71E-06 2.70E-06 2.80E-06 2.38E-04 0.0 3.03E-06 l
PRODUCE CONSUMPTION 1.24E-05 1.24E-05 1.24E-05 1.25E-05 2.03E-05 0.0 1.25E-05 2.38E-05 2.39E-05 2.38E-05 2.39E-05 2.93E-04 3.77E-05 2.42E-05 j
TOTAL i
NEAT ANIMAL (NNW SECTOR AT 3400. METERS)
AIR INHALATION 1.19E-06 1.19E-06 1.19E-06 1.19E-06 5.12E-06 5.64E-06 1.20E 06 EXPOSURE TO SOIL 5.16E-08 6.15E-08 5.16E-08 5.16E-08 5.16E-08 5.16E-08 5.16E-08 LEAFY VEGETABLE CONSUMPTION 4.10E-07 4.10E-07 4.09E-07 4.20E-07 2.64E-05 0.0 4.45E-07 PRODUCE CONSUMPTION 1.97E-06 1.97E-06 1.97E-06 1.98E-06 2.84E-06 0.0 1.98E-06 MEAT CONSUMPTION 3.77E-07 3.77E-07 3.76E-07 3.78E-07 2.14E-06 0.0 3.80E-07
~
~
4.00E-06 4.01E-06 3.99E-06 4.02E-06 3.65E-05 5.69E-06 4.05E-06 TOTAL i
MILK Co*4 (NNW SECTOR AT 8000. NETERS) l AIR INHALATION 3.25E-07 3.25E-07 3.26E-07 3.26E-07 1.46E-06 1.61E-06 3.27E-07 4
------- -_=
=__ _ ---
EXPOSURE TO SOIL 1.14E-08 1.36E-08 1.14E-08 1.14E-08 1.14E-08 1.14E-08 1.14E-08 1
LEAFY VEGETABLE CONSUMPTION 1.19E-07 1.19E-07 1.19E-07 1.21E-07 5.87E-06 0.0 1.27E-07 i
PRODUCE CONSUMPTION 5.89E-07 5.89E-07 5.88E-07 5.90E-07 7.82C-07 0.0 5.91E-07 i
MEAT CONSUMPTION 1.12E-07 1.12E-07 1.12E-07 1.13E-07 5.02E-07 0.0 1.13E-07 COW MILK CONSUMPTION 2.83E-07 2.83E-07 2.82E-07 2.88E-07 1.10E-05 8.25E-05 2.99E-07 1.44E-06 1.44E-06 1.44E-06 1.45E-06 1.96E-05 8.42E-05 1.47E-06 TOTAL MILK GOAT (NNW SECT 0E AT B000. METERS)
EXPOSURE TO SOIL 1.14E-08 1.36E-08 1.14E-08 1.14E-08 1.14E-08 1.14E-08 1.14E-08 l
LEAFY VEGETABLE CONSUMPTION 1.19E-07 1.19E-07 1.19E-07 1.21E-07 5.87E-06 0.0 1.27E-07 PRODUCE CONSUMPTION 5.89E-07 5.89E-07 5.88E-07 5.90E-07 7.82E-07 0.0 5.91E-07 MEAT CONSUMPTION 1.12E-07 1.12E-07 1.12E-07 1.13E-07 5.02E-07 0.0 1.13E-07 COAT MILK CONSUMPTION 5.65E-07 5.65E-07 5.59E-07 5.70E-07 1.35E-05 9.97E-05 5.85E-07 1.72E-06 1.72E-06 1.72E-06 1.73E-06 2.21E-05 1.01E-04 1.75E-06 TOTAL
- -_===
-=-=_ =
i
--
- ------------------------------------------------ __==_
TABLE B-9 9 1 QUARTER 1986 CONTINUOUS RELEASES DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
==___ - ------------.
==--
_-=__-
_ =---=
__ __= -
==_
=-==________----------------
OTNER TOTAL ADULT INFANT INTERNAL EXPOSURE LOCATION AND PATHWAY BODY SKIN LUNG BONE THYROID TNYROID ORGANS i
GARDEN (NNW SECTOR AT 1000. METERS)
AIR INHALATION 3.91E-04 3.91E-04 4.00E-04 3.94E-04 8.12E-04 7.37E-04 3.92E-04 EXPOSURE TO SOIL 1.01E-05 1.19E-04 1.01E-05 1.01E-05 1.01E-05 1.01E-05 1.01E-05 LEAFY VEGETABLE CONSUMPTION 1.20E-04 1.20E-04 1.20E-04 2.02E-04 3.61E-05 0.0 1.24E-04 PRODUCE CONSUMPTION 6.09E-04 6.09E-04 6.09E-04 8.30E-04 7.26E-04 0.0 6.09E-04 TOTAL 1.13E-03 1.13E-03 1.14E-03 1.44E-03 5.16E-03 7.47E-04 1.14E-03 MEAT ANIMAL (NNW SECTOR AT 3400. METERS)
--------_---==-==------
AIR INHALATION 5.40E-05 5.40E-05 5.52E-05 5.44E-05 1.15E-04 1.06E-04 5.41E-05 EXPOSURE TO SOIL 1.14E-06 1.35E-06 1.14E-06 1.14E-06 1.14E-06 1.14E-06 1.14E-06
- LEAFY VEGETABLE CONSUMPTION 1.78E-05 1.78E-05 1.77E-05 2.70E-05 4.14E-04 0.0 1.83E-05 a,
[ PRODUCE CONSUMPTION 9.16E-05 9.16E-05 9.16E-05 1.17E-04 1.05E-04 0.0 9.16E-05 MEAT CONSUMPTION 1.71E-05 1.71E-05 1.71E-05 1.78E-05 4.40E-05 0.0 1.71E-05 TOTAL 1.82E-04 1.82E-04 1.83E-04 2.17E-04 6.79E-04 1.07E-04 1.82E-04 MILK COW (NNW SECTOR AT 8000. METERS)
==-_---
AIR INHALATION 1.58E-05 1.58E-05 1.61E-05 1.59E-05 3.46E-05 3.21E-05 1.58E-05 EXPOSURE TO SOIL 2.47E-07 2.93E-07 2.47E-07 2.47E-07 2.47E-07 2.47E-07 2.47E-07 LEAFY VEGETABLE CONSUMPTION 5.56E-06 5.56E-06 5.55E-06 7.57E-06 9.15E-05 0.0 5.67E-06 PRODUCE CONSUMPTION 2.91E-05 2.91E-05 2.91E-05 3.45E-05 3.20E-05 0.0 2.91E-05 MEAT CONSUMPTION 5.47E-06 5.47E-06 5.47E-06 5.60E-06 1.13E-05 0.0 5.47E-06 COW MILK CONSUMPTION 1.31E-05 1.31E-05 1.31E-05 1.38E-05 1.74E-04 1.26E-03 1.34E-05 TOTAL 6.93E-05 6.94E-05 6.97E-05 7.77E-05 3.43E-04 1.29E-03 6.97E-05 I
MILK GOAT (NNW SECTOR AT 8000. METERS) kkRkhHkLkTION 1.58E-05 1.58E-05 1.62E-05 1.59E-05 3.46E-05 3.21E-05 1.58E-05 EXPOSURE TO SOIL 2.47E-07 2.93E-07 2.47E-07 2.47E-07 2.47E-07 2.47E-07 2.47E-07 LEAFY VEGETABLE CONSUMPTION 5.56E-06 5.56E-06 5.55E-06 7.57E-06 9.15E-05 0.0 5.67E-06 PRODUCE CONSUMPTION 2.91E-05 2.91E-05 2.91E-05 3.45E-05 3.20E-05 0.0 2.91E-05 MEAT CONSUMPTION 5.47E-06 5.47E-06 5.47E-06 5.60E-06 1.13E-05 0.0 5.47E-06 GOAT MILK CONSUMPTION 2.66E-05 2.66E-05 2.66E-05 2.80E-05 2.19E-04 1.55E-03 2.68E-05 TOTAL 8.28E-05 8.28E-05 8.31E-05 9.18E-05 3.89E-04 1.58E-03 8.32E-05
==
==_-__=__===-
=___
- _=....==.
-=.
==--------
_==--_==-------------=_.
m
U TABLE B-lO 8 1 QUARTER 1986 BATCH + CONTINUOUS RELEASES DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
______==- ---=_===__-___
=- --_
_=_____=-
OTHER TOTAL ADULT INFANT INTERNAL EXPOSURE LOCATION AND PATHWAY BODY SKIN LUNG BONE THYROID THYROID ORGANS GARDEN MAXIMUM LOCATION
_________-__--====--=_====
EXPOSURE TO SOIL 1.06E-05 1.25E-05 1.06E-05 1.06E-05 1.06E-05 1.06E-05 1.06E-05 LEAFY VEGETABLE CONSUMPTION 1.23E-04 1.23E-04 1.23E-04 2.05E-04 3.85E-03 0.0 1.27E-04 PRODUCE CONSUMPTION 6.21E-04 6.21E-04 6.21E-04 8.43E-04 7.46E-04 0.0 6.21E-04 TOTAL 1.15E-03 1.15E-03 1.16E-03 1.46E-03 5.45E-03 7.85E-04 1.16E-03 MEAT ANIMAL MAXIMUM LOCATION
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ =.
AIR INHALATION 5.52E-05 5.52E-05 5.64E-05 5.56E-05 1.20E-04 1.12E-04 5.53E-05 EXPOSURE TO SOIL 1.19E-06 1.41E-06 1.19E-06 1.19E-06 1.19E-06 1.19E-06 1.19E-06 i
LEAFY VEGETABLE CONSUMPTION 1.82E-05 1.82E-05 1.81E-05 2.74E-05 4.40E-04 0.0 1.87E-05 m
[ PRODUCE CONSUMPTION 9.36E-05 9.36E-05 9.36E-05 1.19E-04 1.08E-04 0.0 9.36E-05 MEAT CONSUMFTION 1.75E-05 1.75E-05 1.75E-05 1.82E-05 4.61E-05 0.0 1.75E-05 TOTAL 1.86E-04 1.86E-04 1.87E-04 2.21E-04 7.15E-04 1.13E-04 1.86E-04 MILK COW MAXIMUM LOCATION AIR INHALATION 1.61E-05 1.61E-05 1.65E-05 1.62E-05 3.61E-05 3.37E-05 1.61E-05 EXPOSURE TO SOIL 2.58E-07 3.07E-07 2.58E-07 2.58E-07 2.58E-07 2.58E-07 2.58E-07 LEAFY VEGETABLE CONSUMPTION 5.68E-06 5.68E-06 5.67E-06 7.69E-06 9.74E-05 0.0 5.80E-06 PRODUCE CONSUMPTION 2.97E-05 2.97E-05 2.97E-05 3.51E-05 3.28E-05 0.0 2.97E-05 MEAT CONSUMPTION 5.58E-06 5.58E-06 5.58E-06 5.71E-06 1.18E-05 0.0 5.58E-06 COW MILK CONSUMPTION 1.34E-05 1.34E-05 1.34E-05 1.41E-05 1.85E-04 1.34E-03 1.37E-05 TOTAL 7.07E-05 7.08E-05 7.11E-05 7.91E-05 3.63E-04 1.37E-03 7.12E-05 MILK GOAT MAXIMUM LOCATION
_______________=
-_=
AIR INHALATION 1.61E-05 1.61E-05 1.65E-05 1.62E-05 3.61E-05 3.37E-05 1.61E-05 EXPOSURE TO SOIL 2.58E-07 3.07E-07 2.58E-07 2.58E-07 2.58E-07 2.58E-07 2.58E-07 LEAFY VEGETABLE CONSUMPTION 5.68E-06 5.68E-06 5.67E-06 7.69E-06 9.74E-05 0.0 5.80E-06 PRODUCE CONSUMPTION 2.97E-05 2.97E-05 2.97E-05 3.51E-05 3.28E-05 0.0 2.97E-05 MEAT CONSUMPTION 5.58E-06 5.58E-06 5.58E-06 5.71E-06 1.18E-05 0.0 5.58E-06 GOAT MILK CONSUMPTION 2.72E-05 2.72E-05 2.72E-05 2.86E-05 2.32E-04 1.65E-03 2.74E-05 TOTAL 8.45E-05 8.45E-05 8.48E-05 9.35E-05 4.11E-04 1.68E-03 8.49E-05
= - - - - - - - _ _ _ _ _ _ _ _ _
===_________
- - = - - - _ - = _ = = _ _ _ _ _ _ _ _ _ _ _ _
~
TABLE B-11 FIRST QUARTER 1986 BATCH + CONTINUOUS RELEASES POPULATION DOSE (50-MILE) FROM GASEOUS EFFLUENTS (MAN-REM)
-==_
= = - - - - - - - - - - - - - - - - - - - - - - - - - - -
EXPOSURE PATHWAY TOTAL BODY THYROID
=_
AIR SUBMERSION 4.5E-01 4.5E-01 AIR INHALATION 1.6E-03 3.5E-03 EXPOSURE TO SOIL 1.5E-05 1.5E-05 tp LEAFY VEGETABLE CONSUMPTION 1.3E-05 1.7E-04
,L PRODUCE CONSUMPTION 6.9E-05 7.4E-05 d
MEAT CONSUMPTION 1.0E-04 1.9E-04 MILK CONSUMPTION 1.0E-03 1.2E-02 TOTAL 4.5E-01 4.6E-01 AVERAGE DOSE (MREM / PERSON) 2.2E-04 2.3E-04
.== __
_==.-----------------------.
O e
i i
L.
9 I
TABLE B-12 0 2 QUARTER 1986 DOSES FROM LIOUID EFFLUENTS (MREM) 1 l
_==-
1
-=_
OTHER TOTAL ADULT INFANT INTERNAL l
EXPOSURE PATHWAY BODY SKIN LUNG BONE THYROID THYROID ORGANS
~~~~~~
~~
~~
AQUkIIC kk'E XibUM LOCAkIOb~
~
-j
- =--
=.-_------___--
l DRINKING WATER 2.0E-05 2.0E-05 1.9E-05 2.2E-05 3.9E-05 8.7E-05 2.1E-05 2
FISH CONSUMPTION 8.8E-04 8.8E-04 1.4E-04 7.2E-04 9.4E-04 0.0 5.8E-04 INVERTEBRATE CONSUMPTION 1.2E-04 1.2E-04 3.OE-05 1.1E-04 1.2E-04 0.0 1.5E-04 EXPOSURE TO SHORELINE SEDIMENT 2.2E-06 2.5E-06 2.2E-06 2.2E-06 2.2E-06 0.0 2.2E-06 SWIMMING AND BOATING 4.3E-08 1.4E-07 4.3E-08 4.3E-08 4.3E-08 0.0 4.3E-08 j
AQUATIC TOTAL 1.0E-03 1.0E-03 1.9E-04 8.6E-04 1.1E-03 8.7E-05 7.6E-04 4
1 tz L
AQUATIC AT AGRICULTURAL LOCATION v'
DRINKING WATER 2.0E-05 2.0E-05 1.9E-05 2.2E-05 3.9E-05 8.7E-05 2.1E-05
=-__
=-_, _ -
FISH CONSUMPTION 1.0E-04 1.0E-04 1.7E-05 8.7E-05 1.1E-04 0.0 7.0E-05 INVERTEBRATE CONSUMPTIO!8 1.4E-05 1.4E-05 3.5E-06 1.4E-05 1.5E-05 0.0 1.8E-05 EXPOSURE TO SHORELINE SEDIMENT 2.6E-07 3.0E-07 2.6E-07 2.6E-07 2.6E-07 0.0 2.6E-07 SWIMMING AND BOATING 5.2E-09 1.7E-08 5.2E-09 5.2E-09 5.2E-09 0.0 5.2E-09 IRRIGATION AND LIVESTOCK WATERING l
EXPOSUREkoAGRICULTURALSOIL 3.4E-06 4.0E-06 3.4E-06 3.4E-06 3.4E-06 0.0 3.4E-06
-_=__-
LEAFY VEGETABLE CONSUMPTION 3.0E-06 3.0E-06 2.2E-06 4.1E-06 1.7E-05 0.0 3.2E-06 l
PRODUCE CONSUMPTION 1.4E-05 1.4E-05 1.0E-05 2.0E-05 1.5E-05 0.0 1.4E-05 I
MEAT CONSUMPTION 4.2E-06 4.2E-06 4.7E-06 4.8E-06 5.3E-06 0.0 3.8E-05 MILK CONSUMPTION (COW) 1.5E-05 1.5E-05 9.5E-06 1.5E-05 4.4E-05 2.5E-04 9.2E-06 l
MILK CONSUMPTION (GOAT) 3.9E-05 3.9E-05 2.1E-05 3.6E-05 7.3E-05 3.3E-04 1.8E-05 l
1 AGRICULTURAL TOTAL EXCLUDING COW MILK CONSUMPTION 2.0E-04 2.0E-04 8.1E-05 1.9E-04 2.8E-04 4.2E-04 1.9E-04 EXCLUDING GOAT MILK CONSUMPTION 1.8E-04 1.8E-04 7.0E-05 1.7E-04 2.5E-04 3.3E-04 1.8E-04
-_ _ _=
4 i
7--
TABLE B-13 SECOND QUARTER 1986 POPULATION DOSE (50-MILE) FROM LIQUID EFFLUENTS (MAN-REM)
_ - = - - - - - - - - - - - - - - -
.=---=_
EXPOSURE PATHWAY TOTAL BODY THYROID
=_-
AQUATIC 8.0E-05 1.6E-04 DRINKING WATER FISH CONSUMPTION 4.5E-02 4.9E-02 INVERTEBRATE CONSUMPTION 2.8E-05 2.9E-05 EXPOSURE TO CONTAMINATED SEDIMENT 5.8E-06 5.8E-06 SWIMMING AND BOATING 6.0E-08 6.0E-08 to:
E IRRIGATION AND LIVESTOCK WATERING LEAFY VEGETABLE CONSUMPTION 2.3E-07 1.3E-06 1.1E-06 1.1E-06 PRODUCE CONSUMPTION MEAT CONSUMPTION 5.9E-06 7.3E-06 MILK CONSUMPTION 7.8E-05 2.4E-04 EXPOSURE TO CONTAMINATED SOIL 4.9E-07 4.9E-07 4.6E-02 4.9E-02 TOTAL 2.2E-05 2.4E-05 AVERAGE DOSE (MREM / PERSON)
S e
m TABLE B-14 SECOND QUARTER 1986 BATCH RELEASES DOSES FROM NCBLE CASES AT SITE BOUNDARY AND RESIDENCE OF HIGHEST CONCENTRATION Site Boundary [a]
Residence [b]
Beta Air Dose (arad) 4.8E-2 2.5E-2 Gama Air Dose (mrad) 1.5E-2 S.7E-3 1.4E-2 Beta + Cama Skin Dose (mrem) 4.8E-3 Gama Total Body Dose (mrem)
[a] North sector at 663 meters.
[b] North sector at 1000 meters.
B-17 l
l
TABLE B-15 SECOND QUARTER 1986 CONTINUOUS RELEASES DOSES FROM NOBLE GASES AT SITE BOUNDARY AND RESIDENCE OF HIGHEST CONCENTRATION Site Boundary [a]
Residence [b]
6.1E-2 3.3E-2 Beta Air Dose (mrad) 6.4E-2 2.4E-2 Genuna Air Dose (mead)
Beta + Gamma Skin Dose (area) 4.8E-2 2.2E-2 Camma Total Body Dose (mrem)
[a] North sector at 663 meters.
[b] North sector at 1000 meters.
I I
f I
B-18 l
i
TABLE B-16 SECOND QUARTER 1986 BATCH + CONTINUOUS RELEASES DOSES PROM NOBLE CASES AT SITE BOUNDARY AND RESIDENCE OF HIGHEST CONCENTRATION Site Boundary [a]
Residence [b]
Beta Air Dose (arad) 1.1E-1 5.8E-2 Gama Air Dose (mrad) 7.9E-2 3.0E-2 l
6.2E-2 Beta + Camma Skin Dose (mrem) 2.7E-2 Camma Total Body Dose (mrom)
[a] Maximum site boundary location.
[b] Maximum residence location.
)
5835k B-19
TABLE R-17 82 QUARTER 1986 BATCH RELEASES DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
_ _ _ _ _ _ _ = _ _ _
OTNER TOTAL ADULT INFANT INTERNAL EXPOSURE LOCATION AND PATHWAY BODY SKIN LUNG BONE THYROID THYROID ORGANS
=.
= =-
==
_==
_===
= = = _ -
GARDEN (NNW SECTOR AT 1000. METERS) kkkkhhktkTION 1.35E-03 1.35E-03 1.39E-03 1.93E-03 6.26E-03 6.81E-03 1.36E-03 EXPOSURE TO SOIL 1.43E-04 1.69E-04 1.43E-04 1.43E-04 1.43E-04 1.43E-04 1.43E-04 LEAFY VEGETABLE CONSUMPTION 1.42E-03 1.42E-03 1.42E-03 4.62E-03 4.79E-02 0.0 1.49E-03 PRODUCE CONSUMPTION 7.24E-03 7.24E-03 7.22E-03 2.38E-02 8.80E-03 0.0 7.25E-03 TOTAL 1.02E-02 1.02E-02 1.02E-02 3.05E-02 6.31E-02 6.96E-03 1.02E-02 NEAT ANIMAL (SOUTN SECTOR AT 2700. METERS)
=___
- = _ _ -
AIR INHALATION 1.73E-04 1.73E-04 1.78E-04 2.48E-04 8.27E-04 9.04E-04 1.74E-04 EXPOSURE TO SOIL 2.14E-05 2.54E-05 2.14E-05 2.14E-05 2.14E-05 2.14E-05 2.14E-05 y LEAFY VEGETABLE CONSUMPTION 2.09E-04 2.09E-04 2.09E-04 6.89E-04 7.18E-03 0.0 2.19E-04 u PRODUCE CONSUMPTION 1.06E-03 1.06E-03 1.06E-03 3.55E-03 1.30E-03 0.0 1.06E-03 C MEAT CONSUMPTION 6.84E-05 6.84E-05 6.81E-05 1.19E-04 5.43E-04 0.0 6.92E-05 TOTAL 1.53E-03 1.54E-03 1.54E-03 4.63E-03 9.86E-03 9.26E-04 1.55E-03 MILK COW (NW SECTOR AT 5000. METERS) iRkhhkLTION 3.85E-05 3.85E-05 3.96E-05 5.51E-05
-1.89E-04 2.07E-04 3.87E-05 EXPOSURE TO SOIL 4.46E-06 5.29E-06 4.46E-06 4.46E-06 4.46E-06 4.46E-06 4.46E-06 LEAFY VEGETABLE CONSUMPTION 4.50E-05 4.50E-05 4.49E-05 1.45E-04 1.50E-03 0.0 4.69E-05 PRODUCE CONSUMPTION 2.29E-04 2.29E-04 2.28E-04 7.47E-04 2.78E-04 0.0 2.29E-04 MEAT CONSUMPTION 1.57E-05 1.57E-05 1.56E-05 2.62E-05 1.15E-04 0.0 1.59E-05 COW MILK CONSUMPTION 4.64E-05 4.64E-05 4.59E-05 8.72E-05 2.76E-03 2.08E-02 5.03E-05 TOTAL 3.79E-04 3.80E-04 3.79E-04 1.06E-03 4.85E-03 2.10E-02 3.85E-04 MILK GOAT (NW SECTOR AT 5000. METERS)
EXPOSURE TO SOIL 4.46E-06 5.29E-06 4.46E-06 4.46E-06 4.46E-06 4.46E-06 4.46E-06 LEAFY VEGETABLE CONSUMPTION 4.50E-05 4.50E-05 4.49E-05 1.45E-04 1.50E-03 0.0 4.69E-05 PRODUCE CONSUMPTION 2.29E-04 2.29E-04 2.28E-04 7.47E-04 2.78E-04 0.0 2.29E-04 NEAT CONSUMPTION 1.57E-05 1.57E-05 1.56E-05 2.62E-05 1.15E-04 0.0 1.59E-05 GOAT MILK CONSUMPTION 9.21E-05 9.21E-05 9.04E-05 1.77E-04 3.35E-03 2.50E-02 9.74E-05 TOTAL 4.24E-04 4.25E-04 4.23E-04 1.15E-03 5.44E-03 2.53E-02 4.32E-04 a.-------
=-
-=-_
.r---
-=_----------a.--e.e.__
___..e.---
a.---e.eD---
..s.---
TABLE B-18 4
{
92 QUARTER 1905 CONTINUOUS RELEASES DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
OTHER TOTAL ADULT INFANT INTERNAL EXPOSURE LOCATION AND PATHWAY BODY SKIN LUNG BONE THYROID THYROID ORGANS
.-_=_
--===_===
__-_ -____-___---__ =_ ___=__-
i i
GARDEN j
(NNW SECTOR AT 1000. METERS)
__---_-_-____-==
l AIR INHALATION 6.13E-04 6.13E-04 6.21E-04 6.20E-04 1.05E-03 8.60E-04 6.13E-04 EXPOSURE TO SOIL 3.04E-05 3.56E-05 3.04E-05 3.04E-05 3.04E-05 3.04E-05 3.04E-05 LEAFY VEGETABLE CONSUMPTION 1.93E-04 1.93E-04 1.92E-04 3.25E-04 4.56E-03 0.0 1.99E-04 PRODUCE CONSUMPTION 9.95E-04 9.95E-04 9.88E-04 1.41E-03 1.14E-03 0.0 9.99E-04 TOTAL 1.83E-03 1.84E-03 1.83E-03 2.38E-03 6.78E-03 8.90E-04 1.84E-03 l
NEAT ANIMAL (SOUTH SECTOR AT 2700. METERS)
=
__-__---=__ _ _ _ _. _
]
EXPOSURE TO SOIL 7.03E-06 8.25E-06 7.03E-06 7.03E-06 7.03E-06 7.03E-06 7.03E-06 D8 LEAFY VEGETABLE CONSUMPTION 4.10E-05 4.10E-05 4.07E-05 7.16E-05 1.05E-03 0.0 4.25E-05 O PRODUCE CONSUMPTION 2.10E-04 2.10E-04 2.09E-04 3.06E-04 2.45E-04 0.0 2.11E-04 MEAT CONSUMPTION 3.76E-05 3.76E-05 3.74E-05 3.99E-05 1.07E-04 0.0 3.78E-05 TOTAL 4.16E-04 4.17E-04 4.16E-04 5.46E-04 1.62E-03 1.80E-04 4.19E-04 MILK COW (SSW SECTOR AT 4200. METERS)
=__
i AIR INHALATION 3.12E-05 3.12E-05 3.17E-05 3.16E-05 5.49E-05 4.55E-05 3.13E-05 l
EXPOSURE TO SOIL 1.23E-06 1.44E-06 1.23E-06 1.23E-06 1.23E-06 1.23E-06 1.23E-06 l
LEAFY VEGETABLE CONSUMPTION 1.06E-05 1.06E-05 1.05E-05 1.59E-05 1.88E-04 0.0 1.08E-05 PRODUCE CONSUMPTION 5.53E-05 5.53E-05 5.50E-05 7.20E-05 6.12E-05 0.0 5.54E-05 MEAT CONSUMPTION 1.01E-05 1.01E-05 1.00E-05 1.05E-05 2.21E-05 0.0 1.01E-05 I
COW MILK CONSUMPTION 2.46E-05 2.46E-05 2.43E-05 2.65E-05 3.56E-04 2.59E-03 2.52E-05 i
TOTAL 1.33E-04 1.33E-04 1.33E-04 1.58E-04 6.83E-04 2.64E-03 1.34E-04 MILK GOAT (SSW SECTOR AT 4200. METERS)
_ _ _ - _ _ _ _ = _ = _
1 AIR INHALATION 3.12E-05 3.12E-05 3.17E-05 3.16E-05 5.49E-05 4.55E-05 3.13E-05 EXPOSURE TO SOIL 1.23E-06 1.44E-06 1.23E-06 1.23E-06 1.23E-06 1.23E-06 1.23E-06 i
LEAFY VEGETABLE CONSUMPTION 1.06E-05 1.06E-05 1.05E-05 1.59E-05 1.88E-04 0.0 1.08E-05 PRODUCE CONSUMPTION 5.53E-05 5.53E-05 5.50E-05 7.20E-05 6.12E-05 0.0 5.54E-05 MEAT CONSUMPTION 1.01E-05 1.01E-05 1.00E-05 1.05E-05 2.21E-05 0.0 1.01E-05 GOAT MILK CONSUMPTION 5.01E-05 5.01E-05 4.91E-05 5.40E-05 4.48E-04 3.18E-03 5.12E-05 i
f -
TOTAL 1.58E-04 1.59E-04 1.58E-04 1.85E-04 7.75E-04 3.22E-03 1.60E-04 i
=__ _
=
___= -_-___-_-_-_- __
l
3__
TABLE B-19 02 QUARTER 1986 BATCH + CONTINUOUS RELEASES i
DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
_ ___.===. - - = -
_ = _ _.--
=== ------------------------
=-____ ----- __
OTHER l
TOTAL ADULT INFANT INTERNAL EXPOSURE LOCATION AND PATHWAY BODY SKIN LUNG BONE THYROID THYROID ORGANS 1
==
__=-----=_.
_. _=
=
i GARDEN MAXIMUM LOCATION
=_
=-
AIR INHALATION 1.96E-03 1.96E-03 2.01E-03 2.55E-03 7.31E-03 7.67E-03 1.97E-03 EXPOSURE TO SOIL 1.73E-04 2.05E-04 1.73E-04 1.73E-04 1.73E-04 1.73E-04 1.73E-04 LEAFY VEGETABLE CONSUMPTION 1.61E-03 1.61E-03 1.61E-03 4.94E-03 5.25E-02 0.0.
1.69E-03 PRODUCE CONSUMPTION 8.24E-03 8.24E-03 8.21E-03 2.52E-02 9.94E-03 0.0 8.25E-03 1
TOTAL 1.20E-02 1.20E-02 1.20E-02 3.29E-02 6.99E-02 7.85E-03 1.20E-02 l
NEAT ANIMAL j
MAXIMUM LOCATION AkRINHALATkON 2.93E-04 2.93E-04 3.00E-04 3.70E-04 1.04E-03 1.08E-03 2.94E-04 i
EXPOSURE TO SOIL 2.84E-05 3.36E-05 2.84E-05 2.84E-05 2.84E-05 2.84E-05 2.84E-05 O'
LEAFY VEGETABLE CONSUMPTION 2.50E-04 2.50E-04 2.50E-04 7.61E-04 8.23E-03 0.0 2.61E-04 I
b PRODUCE CONSUMPTION 1.27E-03 1.27E-03 1.27E-03 3.86E-03 1.54E-03 0.0 1.27E-03 i
N MEAT CONSUMPTION 1.06E-04 1.06E-04 1.05E-04 1.59E-04 6.50E-04 0.0 1.07E-04 J
I TOTAL 1.95E-03 1.96E-03 1.96E-03 5.18E-03 1.15E-02 1.11E-03 1.97E-03 l
MILK COW j
MAX GUM LOCATION 1
AIR INHALATION 6.97E-05 6.97E-05 7.13E-05 8.67E-05 2.44E-04 2.52E-04 7.00E-05 1
EXPOSURE TO SOIL 5.69E-06 6.73E-06 5.69E-06 5.69E-06 5.69E-06 5.69E-06 5.69E-06 LEAFY VEGETABLE CONSUMPTION 5.56E-05 5.56E-05 5.54E-05 1.61E-04 1.69E-03 0.0 5.77E-05 l
PRODUCE CONSUMPTION 2.84E-04 2.84E-04 2.83E-04 8.19E-04 3.39E-04 0.0 2.84E-04 MEAT CONSUMPTION 2.58E-05 2.58E-05 2.56E-05 3.67E-05 1.37E-04 0.0 2.60E-05 COW MILK CONSUMPTION 7.10E-05 7.10E-05 7.02E-05 1.14E-04 3.12E-03 2.34E-02 7.55E-05 l
TOTAL 5.12E-04 5.13E-04 5.12E-04 1.22E-03 5.53E-03 2.36E-02 5.19E-04 MILK GOAT l
MAXIMUM LOCATION j
AIR INHALATION 6.97E-05 6.97E-05 7.13E-05 8.67E-05 2.44E-04 2.52E-04 7.00E-05 EXPOSURE TO SOIL 5.69E-06 6.73E-06 5.69E-06 5.69E-06 5.69E-06 5.69E-06 5.69E-06 LEAFY VEGETABLE CONSUMPTION 5.56E-05 5.56E-05 5.54E-05 1.61E-04 1.69E-03 0.0 5.77E-05 PRODUCE CONSUMPTION 2.84E-04 2.84E-04 2.83E-04 8.19E-04 3.39E-04 0.0 2.84E-04 i
MEAT CONSUMPTION 2.58E-05 2.58E-05 2.56E-05 3.67E-05 1.37E-04 0.0 2.60E-05 j
GOAT MILK CONSUMPTION 1.42E-04 1.42E-04 1.39E-04 2.31E-04 3.80E-03 2.82E-02 1.49E-04 TOTAL 5.82E-04 5.84E-04 5.81E-04 1.33E-03 6.21E-03 2.85E-02 5.92E-04
=___ _ - - - _ = -
_.. =
- = _ _
=-
_ _ - =
=_
= _ _ _.
1 i
1
e O
TABLE B-20 SECOND QUARTER 1986 BATCH + CONTINUOUS RELEASES POPULATION DOSE (50-MILE) FROM GASEOUS EFFLUENTS (MAN-REM)
EXPOSURE PATHWAY TOTAL BODY THYROID AIR SUBMERSION 6.8E-02 6.8E-02 AIR INHALATION 9.5E-03 3.4E-02 EXPOSURE TO SOIL 3.8E-04 3.8E-04 LEAFY VEGETABLE CONSUMPTION 1.5E-04 3.6E-03 Y
PRODUCE CONSUMPTION 7.6E-04 8.7E-04 MEAT CONSUMPTION 6.6E-04 2.5E-03 N"
MILK CONSUMPTION 7.2E-03 2.4E-01 TOTAL 8.6E-02 3.5E-01 AVERAGE DOSE (MREM / PERSON) 4.2E-05 1.7E-04 S
S
J O
C.
METEOROLOGICAL DATA Meteorological data for 1986 are available for review in the PCE Corporate Office as per Technical Specification 6.9.1.5.4.
Meteorological models and assumptions used in performing the analyses are presented in PGE-1021, "Offsite Dose Calculation Manual".
l l
i
~
r o
.,fl(q
\\
- 'QTp 6p,E>
Portland Gerieral Electric Ccviiptaif s#
~
V
'.y k
8 Ebrt D Wens Vce Presdyt 67 August 29, 1986 Trojan Nuclear Plant Docket 50-344 License NPF-1 Mr. John B. Martin Regional Administrator, Region V U.S. Nuclear Regulatory Commission Creekside Oaks Office Park 1450 Maria Lane, Suite 210 Walnut Creek CA 94596-5368
Dear Sir:
TROJAN NUCLEAR PLANT Semiannual Radioactive Effluent and Waste Disposal Report In accordance with Trojan Nuclear Plant Technical Specifications, attached is the semiannual Radioactive Effluent and Waste Disposal Report for the period January 1, 1986 through June 30, 1986. This information will also be included in the 1986 annual operating report.
Sincerely, S d Bart D. Withers Vice President Nuclear Attachment c: