Proposed Version, with vertical lines in right margin to indicate changes APPENDIX A TECIINICAL SPECIFICATIONS FOR THE ENIVERSITY OF VIRGINIA REACTOR FACILITY LICENSE No. R-66 DOCKET No. 50-62 i
As Revised to Facilitate Permanent Reactor Shutdown, Decontamination and Decommissioning August 3,1999
??a*"iB8!A3188se62 P
UVAR Tech. Specs.
TABLE OF CONTENTS PASC 1.0.
D EFIN ITION S........................................... 3 Figure 1.1 Reactor Facility Boundary Areas..................
10 2.0.
SAFETY LIMIT AND LIMITING SAFETY SYSTEMS SETTINGS......
11 2.1.
Safety Limit.......................................
11 2.2.
Limiting Safety System Settings..........................
15 3.0.
LIMITING CONDITIONS FOR OPERATION.....................
16 3.1.
Reactivity........................................
16 3.2.
Reactor Safety System...................... -..........
18 3.3.
Reactor Instrumentation...............................
20 3.4.
Radioactive Effluents.................................
22 3.5.
Confm' ement
......................................23 3.6.
Limitations on Experiments.............................
24 3.7.
Operation with Fueled Experiments
.......................26 3.8.
Height of Water Above the Core in Natural Convection Mode of 0peration..................................
27
{
3.9.
Rod-Drop Times....................................
28 3.10.
Emergency Removal of Decay Heat (deleted)
.................29 3.11.
Primary Coolant Condition............................
30 i
4.0.
SURVEILLANCE REQUIREMENTS '...........................
32 4.1.
Shim Rods (Deleted).................................
32 4.2.
Reactor Safety System (Deleted)..........................
32 I
4.3.
Emergency Core Spray System (Deleted).....................
32 4.4.
Area Radiation Monitoring Equipment......................
33 4.5.
Maintenance (Deleted)................................
33 4.6.
Confinement (Deleted)................................
32 4.7.
Airborne Effluents (Deleted)............................
32 4.8.
Primary Coolant Conditions
............................34 4.9 Surveillance of Activity in Secondary System (Deleted)...........
32 4.10 Surveillance of Reactor Poolwater Level
....................34 5.0.
DESIGN FEATURES.....................................
35 5.1.
Reactor Fue1 Specifications.............................
35 5.2.
Reactor Building (Deleted).............................
37 5.3.
Fuel Use and Storage.................................
3 8 6.0.
ADMINISTRATIVE CONTROLS.............................
39 6.1.
Organization.....................................
39 6.2.
Radiation Safety, Reactor Safety & Reactor Decommissioning Committees 41 6.3.
Standard Operating Procedures
..........................49 6.4.
Review and Approval of Experiments.......................
50 6.5.
Plant Operating Records...............................
52 6.6.
. Required Actions
....................................54 6.7.
Reporting Requirements...............................
55 l
L UVAR Tech. Specs.
1.0.
DEFINITIONS Administrative Controls - Administrative controls are those organizational and procedural
. requirements that are established by the reactor licensee management.
Anolicability: As regards use of this term in the Technical Specifications, it is a statement that indicates which components are involved.
Basia: ' As regartis use of this term in the Technical Specifications, it is a statement that l
provides the background or reason for the choice of specification (s), or references a L
's particular portion of the Safety Analysis Report (SAR) that does.
Beamports: The beamports are the two 8-inch diameter neutron beamports that penetrate the shield on the south side of the UVAR pool.
Channel: A channel is the combination of sensor, line, amplifier, and output devices which are connected for the purpose of measuring the value of a parameter. (Also, see definition for uneneuring channen, l
Channel Cahbration: A channel calibration is an adjustment of the channel such that its output corresponds with acceptable range and accuracy to known input values of the l
parameter which the channel measures. Calibration shall encompass the entire channel, including equipment actuation, alarm, or trip and shall be deemed to include a channel test.
l' Channel Check: A channel check is a qualitative verification of acceptable performance by
[
observation of channel behavior, or comparison of the channel with other independent l
channels or systems measuring the same variable, where this capability exists.
Channel Test: A channel test is the introduction of a signal into a channel to verify that it is
- operable, l
Confinement: Confinement means a closure on the overall facility that controls the movement of air into it and out through a controlled path.
Decommissioning: Decommissioning means to remove a facility or site safely from service and reduce residual radioactivity to a level that permits: (1) release of the property for I:
unrestricted use and termination of the license; or (2) release of the property under restricted I.
conditions and termination of the license (10CFR50.2). Decommissioning does not include storage or removal of fuel, or non-radiological demolition activities.
l Decontamination: Decontamination are the activities employed to reduce the levels of radioactive and/or hazardous contamination in or on material, structures and equipment.
Demien Features: The definition for design features is as defined in 10 CFR 50.36.
L Fuce.. r,e.crivity: Excess reactivity is that amount of reactivity that would exist if all l
reactivity control devices were moved to the maximum reactive condition from the point where the reactor is exactly critical (k,, = 1).
3-L o
UVAR Tech. Specs.
Exneriment: Any operation, hardware, or target (excluding devices such as detectors, foils, activation samples in an irradiation facility, etc...) that is designed to investigate non-routine reactor characteristics or that is intended for reactor irradiation within the UVAR pool, on or in the beamport or irradiation facility, and that is not rigidly secured to a core or shield structure so as to be a part of their design.
Experimental Facility: An experimental facility is a structure or device associated with the reactor that is intended to guide, orient, position, manipulate, or otherwise facilitate a multiplicity of experiments of similar character.
Exoerimental Methods: Experimental Methods are written and approved instructions which provide guidance to the reactor staff or experimenters for the completion of tasks specified in Experimental Procedures (EPs). While EPs, and changes thereto, are reviewed and approved by the Reactor Safety Committee (RSC), experimental methods are written and reviewed by reactor staff and/or experimenters and approved by a reactor supervisor or administrator. Newly developed experimental methods or changes to existing experimental methods should be sent to the RSC as information items.
Experimental Procedures: Written procedures reviewed and approved by the Reactor Safety Committee which describe the manner in which experiments are run in conjunction with the UVAR, to assure reactor and radiological safety. Operational limits peculiar to the experiment are included in these procedures. Detailed implementation of experimental procedures may be made through the use of experimental methods.
Explosive Material: Explosive material is a solid or liquid that is categorized as a Severe, Dangerous, or Very Dangerous Explosion Hazard in " Dangerous Properties of Industrial Materials". by N.I. Sax, or is given an Identification of Reactivity (Stability) index 2, 3, or 4 by the National Fire Protection Association in its publication 704-M, " Identification System for Fire Hazards of Materials," also enumerated in the " Handbook for Laboratory Safety" published by the Chemical Rubber Co.
j Forced Convection Mode: The reactor is in the Forced Convection Mode when the flow header is up and the primary pump is operating.
j Fueled Exoeriment: A fueled experiment is an experiment that contains U-235, U-233 or Pu-239 in levels exceeding trace quantities. Reactor fuel elements are not included in this definition. (Also, see the definition for trace auantities and TS 3.7.).
Important Process Variables: Important process variables are measurable parameters that individually or in combination reflect the basic physical condition of physical barriers. They may include fuel temperature, reactor power, reactor coolant flow rate, reactor coolant inlet or outlet temperature, pool level, or coolant pressure. (Also, see definition for safety limi13)
Large Access Facilities: The large access facilities are the two large openings approximately 5 ft wide by 6 ft high that penetrate the shield on the south side of the UVAR pool.
Licensed Operator: A licensed operator is an individual authorized by the U.S. Nuclear Regulatory Commission to carry out the duties and responsibilities associated with operation of the UVAR.'(Also, see definitions for Senior Reactor Ooerator and Reactor Ooerator).
4
UVAR Tech. Specs.
Limitino Canditinne for Oneratians: Limiting Conditions of Operation (LCOs) are those administratively established constraints on equipment and operational characteristics that shall be adhered to during operation of the facility. The LCOs are the lowest functional capability or performance level required for safe operation of the reactor.
l 1 imitino Safety Svetem 5:ettinas:. Limiting Safety System Settings (LSSS) are those limiting values for settings of the safety channels by which point protective action must be initiated.
The LSSS are chosen so that automatic protective action will terminate the abnormal situation before a safety limit is reached. The calculation of the LSSS shall include the process uncertainty, the overall measurement uncertainty, and transient phenomena of the
(
process instrumentation. To achieve operational flexibility, it is recommended that actual trip points, where possible, be set more conservatively than specification values.
Measured Value: The measured value of a parameter is the value of the variable as it appears on the output of a measuring channel.
Measuring Channel: A measuring channel is the combination of sensor, line, amplifier, and output devices which are connected for the purpose of measuring the value of a parameter.
(Also, see definition for channel).
Methods: Methods are written and approved instructions which provide guidance to the reactor staff, and/or subcontractors working for reactor management, for the completion of tasks specified in Standard Operating Procedures (SOP's). While SOP's, and changes thereto, are reviewed and approved by the UVAR Decommissioning Committee (UDC),
methods are written and reviewed by the reactor staff and/or subcontractors working for reactor management, and approved by the reactor supervisor or reactor director. Newly developed me,thods, or changes to existing methods, should be sent to the UDC as l
information items.
)
l Movable Exneriment: A movable experiment is one where it is intended that all or part of i
the experiment may be inserted, removed, or manipulated in or near the core while the reactor is critical.
Natural convection Mode: The reactor is in the Natural Convection Mode when the flow l
through the core is maintained by the buoyancy forces associated with the water being l
heated by the reactor.
f Obiective: As regards use of this term in the Technical Specifications, it is a statement that indicates the purpose of the specifications.
On Call: To be on call refers to an individual who (1) has been specifically designated and the designation is known to the operator on duty, (2) keeps the operator on duty informed of where he may be contacted and the phone number, and (3) is capable of getting to the Reactor Facility within a reasonable time under normal conditions (e.g., approximately 30 min).
Operable: A component or system is operable when it is capable of performing its intended function in a normal manner,
, L
p1 l
UVAR Tech. Specs.
Qparadag: - A component or system is ;aating when it is performing its intended function in a normal manner.
' Protective Action: Protective action is the initi: tion of a signal or the operation of equipment within the reactor safety system in response to a variable or condition of the reactor having reached a specific limit.
- (1) channel level. - At the protective instrument channel level, protective action is the generation and transmission of a trip signal indicating that a reactor variable has reached a specified limit.
(2) subsystem level. At the protective instrument subsystem level, protective action is the 4
generation and transmission of a trip signal indicating that a specified limit has been reached.
NOTE: Protective action at this level would lead to the operation of the safety shutdown equipment to immediately shut down the reactor.
(3) in=tmment sv= tem level. At the protective instrument system level, protective action is the generation and transmission of the command signal for the safety shutdown i
L
' equipment to operate.
I (4) safety svatem level. At the reactor safety system level, protective action is the operation of sufficient equipment to immediately shut down the reactor.
l Panctor Facilitv: Reactor Facility refers to the immediate site-area surrounding and i
- including the reactor building which houses the University of Virginia Reactor (UVAR).
The site boundary is demarcated by a chain link fence and gates. (See Figure 1.1) j Panctivity I.imita: Reactivity limits for experiments are quantities referenced to an average pool temperature of <90* F with the effect of xenon poisoning on core reactivity accounted for if greater than or equal to 0.07$. The reactivity worth of samarium in the core will not L-be included in reactivity limits. The reference core condition will be known as the cold, xenon-free critical condition.
[-
Reactivity Worth of an Experiment: The reactivity worth of an experiment is the value of
- the reactivity change that results from the experiment being inserted into or removed from its intended position.
. Panc'ar Ooeratino: The reactor is operating whenever it is not secured or shutdown.
Reactor Operation: The reactor is in operation when not all of the shim rods are fully inserted and six or more fuel elements are loaded in the grid plate.
Panetar Onerator: ' An NRC-licensed reactor operator is an individual who is certified by the
~ NRC and the reactor administration to manipulate the controls of the UVAR reactor. L t
UVAR Tech. Specs.
Reactor Safety Systems: Reactor safety systems are those systems, including their associated input channels, which are designed to initiate automatic reactor protection or to provide information for initiation of manual protective action.
Reactor Secured: The reactor'is secured when:
(1) Either there is insufficient moderator available in the reactor to attain criticality or there is insufficient fissile material present in the reactor to attain criticality under optimum available conditions of moderation and reflection, or j
(2) The following conditions exits:
a.
All shim rods are fully inserted,
- b. The console key is in the OFF position and is removed from the lock, and c.
No work is in progress involving core fuel, core structure, installed control rods, or j
control rod drives unless they are physically decoupled from the control rods, and
- d. ; No experiments are being moved or serviced that have, on movement, a reactivity worth exceeding the maximum reactivity value allowed for a single experiment, or
. one dollar, whichever is smaller.
Reactor Shutdown: The reactor is shut down if it is subcritical by at least one dollar in the
)
reference core condition with the reactivity worth of all installed experiments included.
Permanent Reactor Shutdown: A reactor is in a permanent shutdown state when all reactor -
fuel elements have been removed from the reactor gridplate and an administrative order is in place to prevent a reloading of the core.
Reactor Staff: The Reactor Director and all personnel administratively reporting to him.
Reference Core Canditinn: The condition of the core when it is at ambient temperature (cold) and the reactivity worth of xenon is negligible (<0.30$).
Regulating Rod: The regulating rod is a control rod of low reactivity worth fabricated from stainless steel and used primarily to maintain an intended power level. The regulating rod need not have scram capability. The rod may be controlled by the operator with a manual switch or by the automatic servo-controller.
Reportable Occurrence:. A reportable occurrence is any of the conditions described in Section 6.6.2 of these specifications.
Research Reactor: A research reactor is defined as a device designed to support a self-sustaining neutron chain reaction for research, development, education, training, or experimental purposes, and that may have provisions for the production of radioisotopes.
Safety I imita: Safety Limits are limits on important process variables that are found to be necessary to reasonably protect the integrity of the principal physical barriers that guard against the uncontrolled release of radioactivity. - The principal physical barrier is often the fuel cladding. - (Also, see the definition for imnortant process variablesh
. if
UVAR Tech. Specs.
Scram Time: Scram time is the elapsed time between the initiation of a scram signal and a specified movement of a control or safety device.
Secured Exneriment: A secured experiment is an experiment, experiment facility, or component of an experiment that is held in a stationary position relative to the reactor by mechanical means. The restraining forces must be substantially greater than those to which the experiment might be subjected by hydraulic, pneumatic, buoyant, or other forces that are i
normal to the operating environment of the experiment or by forces that can arise as a result of credible malfunctions.
J Senior Reactor Operator: An NRC-licensed senior reactor operator is an individual who is certified by the NRC and the reactor administration to manipulate the controls of the UVAR j
reactor and to direct the activities of reactor operators.
Shall. should and mav: The word "shall" is used to denote a requirement; the word "should" to denote a recommendation; and the word "may" to denote permission, neither a requirement nor a recommendation.
Shim Rod: A shim rod is a control rod fabricated from borated stainless steel, which is used to compensate for fuel burnup, temperature, and poison effects. A shim rod is magnetically coupled to its drive unit allowing it to perform the function of a safety rod when the magnet is de-energized (Also, see definition for regulating rod).
Shutdown Marcin: Shutdown margin is the minimum shutdown reactivity necessary to provide confidence that the reactor can be made suberitical by means of the control and safety systems starting from any permissible operating condition and with the regulating rod and the most reactive shim rod in their most reactive position, and that the reactor will remain suberitical without further operator action.
Specification (s): As regards use of this term in the Technical Specifications, it is a statement that provides specific data, conditions, or limitations that bound a system or operation. This statement is the most important statement in the technical specifications agreement. Only the specifications statements are governing.
Standard Oneratine Procedums: Written procedures reviewed and approved by the Reactor Safety Committee to assure reactor safety and compliance with federal regulations, which describe the manner by which the reactor staff will operate and maintain the UVAR. (Also, l
see TS 6.3).
I Surveillance Requirements: The definition for surveillance requirements is as defined in 10 CFR 50.36.
j i
Surveillance Time Intervals:
l Annually (interval not to exceed 15 months) j Semiannually (interval not to exceed 71/2 months)
Quarterly (interval not to exceed 4 months)
Monthly (interval not to exceed 6 weeks)
Weekly (interval not to exceed 10 days) j Daily (must be done during the calendar day) 1 l l
l.
i L
o
p f
UVAR Tech. Spccs, Trace Onnatities: As related to fissionable or fissile nuclides such as U-235, U-233 or 15-l 232 potentially present in environmental samples on which neutron activation analysis ma,'
i be attempted, trace quantities are taken to be negligibly-small concentration levels below 1 R parts-per-million (ppm). (Also, see the definition for Fueled Exneriment).
Tried Exneriment: A tried experiment is (1) an experiment previously performed in the UVAR or (2) an experiment for which the size, shape, composition, and location does not differ significantly enough from an experiment previously performed in the UVAR to affect reactor safety.
True Value: The true value is the actual value of a parameter.
Unscheduled shutanwn: An unscheduled shutdown is defined as any unplanned shutdown of the reactor caused by the actuation of the reactor safety system, operator error, equipment malfunction, or manual shutdown in response to conditions that could adversely affect safe
. operation, not including shutdowns that occur during testing nor check-out operations.
(rest of page intentionally left blank) l l )
- 7. - -
UVAR Tech. Specs.
\\
f'
%.\\' Q'O j!!/lj j$
i l
(,..
'% \\';4\\s [ z
]
s
.x '
o s
n 8
8 0-
.m' 2
\\
\\
\\ k, Yll i
\\\\
N
<h k f'd'lx @$
hQ ks "4' %u$;
l!
/Ni g%
s xx e -Ij dyNT1 i
q m
r s
1
\\
(\\\\'
\\q
- ~
1 1
S n\\ 'u' l
\\
1 g-UVAR Tech.' Specs ~.
2.0.
SAFETY LIMIT AND I IMITING SAFETY SYSTEM SETTINGS f
~
~2.1.
Rafatv I imite -
. 2.1.1.. Enfety I imite in Forced Convection Mode of Ooeration Applicability:' This specification applies to the interrelated variables associated with l
core thermal and hydraulic performance in the forced convection mode of operation.
l These variables are:
~ P = Reactor thermal power
.W = Reactor coolant flow rate Ti = Reactor coolant inlet temperature
- L = Height of water above the core.
Objective: The objective is to ensure that the integrity of the fuel clad is maintained.
Specification: In the forced convection mode of operation:
l (1) The pool water level shall not be less than 19 ft above the top of the core.
(2) The reactor coolant inlet temperature shall not be greater than 111*F.
(3) The true value of reactor coolant flow shall not be below 575 gpm.
(4) The combination of true values of reactor core power and reactor coolant flow shall be below the line defm' ed by:
P.= 0.24 + (4.5 x 104 ? W)
P = 0 for W < 575; P in MW, W in gpm l
The allowed region of operation is shown by the unshaded region of Figure 2.1.
Basis: " Above 575 gpm in the region of full power operation, the criterion used to establish the safety limit was a burnout ratio of 1.49 including the worst variation in the j
manufacturer's tolerance and specification, hot channel factors and other appropriate uncertainties, The analysis is given in the LEU SAR.'
L
. Below 575 gpm buoyancy forces competing with forced convection may lead to flow
. instabilities in some of the channels and is therefore not allowed. The analysis of the loss of flow transient shows that during the transition from forced convection to natural convection following a loss of flow and reactor scram that the fuel temperature is well
. below the temperature at which fuel clad damage could occur.
I i t
1 ki NoS @0.
008 I
oo i
G i
0 e
04 1
yo iF 0
n 0
o I
2 it 1
c f
c A
v, pa
,c w,
s o
e c
1 ot c
o ro F
,9, ht v
i g
ren 0
1 0
i 8c L
ro y
t u
e f
%Sa 00 1
6
,ug iF 0
I 04 002 N
s o
8 7
6 O
4 3
2 1
ks:. lQ Wed W!e bg4
'.?
UVAR Tech. Specs, 2.1.2.
Safety 1 imits in the Natiiral Convection Mode of Operation Apphcability: This specification applies to the interrelated variables associated with core thermal and hydraulic peiformance in the natural convection mode of operation.
These variables are:
- P = Reactor thermal power T = Reactor coolant inlet temperature i
Obiective: The objective is to ensure that the integrity of the fuel clad is maintained.
Specification: In the natural convection mode of operation:
(1) The true value of reactor power shall not exceed 750 kW.
(2) The reactor coolant inlet temperature shall not be greater than 11l'F.
Basis: The criterion for establishing a safety limit with natural convection flow is established as a fuel plate temperature. The analysis for natural convection flow shows that at 750 kW, the maximum fuel plate temperature is well below the temperature at which fuel clad damage could occur.
(rest of page intentionally left blank) 1 3
9
)
i l
UVAR Tech. Specs.
2.1.3.
Safety I imit for the Transition from Forced to Natural Convection Mode of Ooeration Applicability: This specification applies to the condition when the reactor is in transition from forced convection flow to natural convection flow.
Obiective: The objective is to ensure that the integrity of the fuel clad is maintained.
Specification: The current to the control rod magnets must be off when the reactor is making a transition from forced to natural convection.
Basis: The safety analysis of the loss of coolant transient demonstrates that the fuel plate temperature is maintained well below the temperature at which fuel clad damage could occur during the transition from forced downflow through flow reversal to the establishment of natural convection provided that the loss of flow transient is accompanied by a scram.
(rest of page intentionally left blank) l l
l t
1 i
l
! p
r-UVAR Tech. Specs.
2.2.
Limiting Safety System Settings Applicability: These specifications apply to the set points for the safety channels monitoring reactor thermal power, coolant flow rate, reactor coolant inlet temperature, and the height of water above the core.
Objective: The objective is to ensure that automatic protective action is initiated to prevent the safety limit from being exceeded.
Specifications:
2.2.1.
Forced Convection Mode For operation in the forced convection mode, the limiting safety system settings shall be:
Reactor Thermal Power 3.0 MWt (max)
=
Reactor Coolant Flow Rate 900 gpm (min)
=
Reactor Coolant Inlet Temperature 108 F (max)
=
Height of Water above Core 19'2" (min)
=
Reactor Period 3.3sec (min)
=
2.2.2.
Natural Convection Mode For operation in the natural convection mode, the limiting safety system settings shall be:
Reactor Power 300 kWt (max)
=
Reactor Coolant Inlet Temperature 108 F (max)
=
Reactor Period 3.3sec (min)
=
Bases. The analysis in the LEU SAR shows there is sufficient margin between these settings and the safety limit under the most adverse conditions of operation:
(2.2.1.) For the forced convection mode, the LEU SAR considers accidents with reactor power at 3.45 MW, a period of 3 seconds, pool inlet temperature of 111*F and a coolant flow of 837 gpm. The maximum fuel plate temperature calculated was considerably below the aluminum clad melting point. The LSSS specified above for this mode of operation are more conservative than the parameters used in the LEU SAR analysis.
(2.2.2.) With natural convection flow, there is no minimum coolant flow rate and no minimum height of water above the core so long as there is a path for flow (see Section 3.8 of these specifications). The LEU SAR shows that the maximum fuel plate temperature l
under natural convection with initial power of 750 kW and pool inlet temperature of Ill"F was well below the aluminum clad melting point. The LSSS specified above for this mode of operation are below the analyzed condition.
r o
E 1
UVAR Tech. Specs.
3.0.
LIMITING CONDITIONS FOR OPERATION
~3.1.
P-tivity I
L Applicabihtv: This specification applies to the reactivity condition of the reactor and the reactivity worth of control rods and experiments.
Obiectives: The objectives are to ensure that the reactor can be shut down at all times and
- that the safety limit will not be exceeded.
Specification:. The reactor shall not be operated at powers in excess of 1 kW unless the following conditions exist:
.(1) The minimum shutdown margin provided by shim rods, with secured experiments (see Section 1.0) in place and referred to the cold, xenon-free condition with the highest-worth shim rod and the regulating rod fully withdrawn, is greater than 0.55$.
(2) Ar4 experiment with a reactivity worth greater than 0.60$ must be a secured experiment.
(3) The total reactivity worth of the two experiments having the highest reactivity worth is less than 2.00$.
(4) The total reactivity worth of all experiments is less than 2.50$.
(5) The maximum excess reactivity with fixed experiments in place and referred to cold, xenon-free condition shall be limited to 6.50$.
Bass: Operation of the reactor at power levels below I kW to measure the reactivity worth of untried expenments, and to measure the excess reactivity of new core loadings, is allowed with procedures approved by the Reactor Safety Committee. Reactivity is' measured in dollars from the reactor period, and as such is the quantity of safety significance. Reactivity limits expressed in $ are more appropriate for the Technical Specifications, since they are
- not dependent on the type of fuel used in the reactor or on the geometry of a particular core loading.
(1) The shutdown margin required by Specification 3.1(1) is necessary so that the reactor
- can be shut down from any operating condition and remain shut down after cooldown and xenon decay, even if the highest worth shim rod should stick in the fully withdrawn position, and with no credit taken for the non-scrammable regulating rod.
(2) The reactivity of 0.60$ in Specification 3.1(2) corresponds to an asymptotic 3-sec
- period. If this period were sustained without scramming the reactor until the reactor
- power reaches the maximum true value for the Limiting Safety System Setting (IESS) l for the High Power Scram (at which time the reactor scrams on high power), the i
resulting power overshoot would not exceed the safety limit for power vs. flow.
I (3) The reactivity of 2.00$ in Specification 3.l(3) is less than 2.16$ which corresponds to a 6.9-msec period. Reactor Core DU-12/25 of the SPERT-1 series of tests had MTR plate type elements (
Reference:
Thompson and Beckerly " Technology of Nuclear m
i UVAR Tech. Specs.
)
Reactor Safety," Volume 1, page 683 (1964)). A 6.9-msec period was nondestructive.
The simultaneous failure of more than two experiments is considered unlikely.
(4) The total reactivity of 2.50$ in Specification 3.l(4) places a reasonable upper limit on the worth of all experiments.
(5) The limit of 6.50$ on excess reactivity is to allow for xenon override,,d operational flexibility and to ensure that the operational reactor is reasonably similar in configuration to the reactor core analyzed in the SAR. In general, the excess reactivity is limited by the shutdown margin requirement, (rest of page intentionally left blank) l l e
p l
UVAR Tech. Specs.
L l
3.2.
Paactar Safety Sv='am -
Applicabditv: This specification applies to the reactor safety system channels.
' Obiective: The objective is to stipulate the minimum number of reactor safety system channels that must be operable to ensure that the safety limit is not exceeded during normal operation.
Snacifica' inn: The reactor shall not be operated unless the safety system channels described in Table 3.1 Rnfety Svatem Channele are operable.
Bancs The startup interlock, which requires a neutron count rate of at least 2 counts per second (CPS) before the reactor is operated, ensures that sufficient neutrons are available for proper operation of the startup channel.
. The pool-water temperature scram provides protection to ensure that if the limiting safety system setting is exceeded an immediate shutdown will occur to keep the fuel temperature below the safety limit. Power level scrams are provided to ensure that the reactor power is maintained within the licensed limits and to protect against abnormally high fuel temperatures. The manual scram allows the operator to shut down the reactor if an unsafe or abnormal condition arises. The period scram is provided to ensure that the power level does not increase above that described in the SAR.-
Specifications on the pool-water level are included as safety measures in the event of a serious loss of primary water. Reactor operations are terminated if a major leak occurs in the primary system. The analysis in the SAR shows the consequences resulting from loss of l
' coolant.
l The bridge radiation monitor gives warning of a high radiation level in the reactor room from failure of an experiment or from a significant drop in pool-water level.
(
- A scram from loss of primary coolant flow, loss of power to the pump, or application of
- power to the pump when operating in the natural convection mode, protects the reactor from overheating.
l l
Air pressure to the header above ambient results in a scram to:
[
- 1) Ensure that the header falls with loss of primary pump power when the reactor is operating in the forced convection mode.
l 2)- Prevent raising the header when the reactor is in the natural convection mode.
- 3) Avoid producing additional Ar-41 by activating air introduced into the header.
i (rest of page intentionally left blank) L
UVAR Tech. Specs.
I TABLE 3.1 SAFETY SYSTEM CHANNELS Minimum Operating Mode Measuring Channel Set Point
- j Function No. Operable Required Pool water level monitor 2
19'2" (min)
Scram Forced convection Bridge radiation monitor 1
30 mr/hr Scram All modes Pool water temperature 1
108"F (max)
Scram All modes loss of power Scram Forced convection Power to primary pump 1
application of Natural Scram power convection Primary coolant flow I
900 gpm (min)
Scram Forced convection Prevents Startup count rate 1
2 cps (min) withdrawal of Reactor startup any shim rod Manual button 1
Scram All modes 3 MWt (max)
Scram Forced convection Reactor power level 2
Natural 0.3 MWt (max)
Scram convection Reactor period 1
3.3 sec (min)
Scram All modes Air pressure to header I
above ambient Scram All modes I
Values listed are limiting set points. For operational convenience, set points may be changed to more conservative values.
l I
l t l l
I
p UVAR Tech. Specs.
3.3.
Peactor In=tmmentatinn Anplicability: This specification applies to the instrumentation that must be operable for safe operation of the reactor.
Obiective: The objective is to require that sufficient information is avathble to the operator to ensure safe operation of the reactor.
Specification: The reactor shall not be operated unless the measuring channels described in Section 3.2 Reactor Safety Svatems and in Table 3.2 Measuring Channels are operable.
Bass: The neutron detectors and the core gamma monitor provide assurance that measurements of the reactor power level are adequately covered at both low and high power ranges.
The radiation monitors provide information to operating personnel of a decrease in pool-water level and of an impending or existing danger from radiation contamination or streaming, allowing ample time to take necessary precautions to initiate safety action.
The reactor room constant air monitor and reactor face monitor provide redundant measures of abnormal high radiation levels. Because the other measuring channels for determining the radiation levels are required for reactor operation, the reactor can be operated safely if these monitors are not functioning for short periods of time.
1 l
(rest of page intentionally left blan k) i i
i b
l UVAR Tech. Specs.
Table 3.2 Measuring Channels Minimum No.
Operating Mode in Which Measuring Channel Operable Required Linear power 1
All modes Intermediate power (Log N) and period 1
All modes Core gamma monitor
- 1 Forced convection mode
- Reactor room constant air monitor
- 1 All modes
- Bridge radiation monitor 1
All modes i
Reactor face monitor
- Pool-water level monitor 2
Forced convection mode i
Pool-water temperature 1
All modes Primary coolant flow 1
Forced convection mode Startup count rate 1
Reactor startup i
Reactor power level 2
All modes The reactor room constant air monitor, reactor face monitor, and core gamma monitor may be out of service for a period not to exceed 7 days without requiring reactor shutdown. If the reactor face monitor cannot be repaired within 7 days, it may be replaced by a locally alarming monitor of similar range for up to 30 days without requiring a reactor shutdown.
l !
UVAR Tech. Specs.
3.4.
R=dinactive Efnuanen Anolicahilitv: This specification applies to the monitoring of radioactive effluents from the Reactor Facility. Airborne and liquid effluents are discussed separately in the following sections.
l 3.4.1.
Airborne Ef0aante Obpective: The objective is to ensure that exposure to the public resulting from the release of Ar-41 and other airborne effluents to the environment will be below the limits of 10 CFR 20 for unrestricted areas, i
Knacificatian: The activity of gases released beyond the Reactor Facility's site boundary shall not exceed 10 CFR 20 limits. When a neutron beampon vented to the atmosphere is drained of water during reactor operations and until such time as the beamport has been refilled, the effluent shall be monitored by an instrument located in the effluent vent and the effluent vent will have sufficient flow to maintain releases within 10 CFR 20 limits.
Bases
- A basis for this specification is given by the analysis in the SAR. Compliance with federal regulation is another basis.
3.4.2.
I lanid Efnuante Obiective: The objective is to ensure that exposure to the public resulting from the release of radioactive effluents will be below the limits of 10 CFR 20 for unrestricted areas.
Knacincatian: The activity of liquids released beyond the Reactor Facility's site boundary shall not exceed 10 CFR 20 limits.
Basis: The basis for this specification is compliance with federal regulations.
(rest of page intentionally left blank).
b l-UVAR Tech. Spccs.
3.5.
Confmement Anolienhility: This specification applies to the capability ofisolating the UVAR.'s reactor l
room, when necessary.
L l.
Obiective: The objective is to prevent exposure to the public from exceeding the limits of 10 CFR 20 for unrestricted areas, resulting from airborne activity released into the UVAR's reactcr room, by providing confinement.
Specification: The reactor shall not be operated unless the following equipment is operable.
Fnninment Function Truck door closed switch Scram reactor when truck door is not fully closed Ventilation duct doors Close and seal when Bridge Radiation Monitor alarms Personnel door Close and seal when Bridge Radiation Monitor alarms Emergency exit manhole Water level is high enough to form a water water level seal at least 6 in, in depth Basis: The basis for this specification is compliance with federal regulations.
(rest of page intentionally left blank) l i...
ff UVAR Tech. Specs.
L 3.6.
1 imit='iaa on F nariman'=
i Innliemhilitv' These specifications apply to experiments installed in the reactor and its experimental facilities.
Olsective: The objective is to prevent damage to the reactor or excessive release of radioactive materials in the event of an experiment failure.
Enneifirmeinna:
3.6.1.
Danctivity The mactor shall not be operated unless the following conditions exist:
(1) The reactivity worth of all experiments shall be in conformance with specifications in Section 3.1.
(2) Movable experiments must be worth less than 0.13$.
(3) Experiments wonh more than 0.13$ must be inserted or removed with the reactor shut down except as noted in Item (4).
(4) Previously tried experiments with measured worth less than 0.50$ may be inserted or removed with the reactor 2.70$ or more subcritical.
- (5) If an experiment worth more than 0.50$ is inserted in the reactor, a procedure approved by the Reactor Safety Committee shall be followed.
3.6.2.
Containers (1). All materials to be irradiated in the reactor shall be either corro< ion resistant or encapsulated within corrosion resistant containers.
(2) Irradiation containers to be used in the reactor in which a static pressure will exist or in which a pressum buildup is predicted shall be designed and tested for a pressure exceeding the maximum expected by a factor of 2.
3.6.3.
Dan =ar== unearint.
Explosive material shall not be allowed in the reactor unless specifically approved by the Reactor Safety Committee. Experiments reviewed by the Reactor Safety Committee in which the material is potentially explosive, either while contained or if it leaks from the container, shall be designed to prevent damage to the reactor core or to the control rods or instrumentation, and to prevent any changes in reactivity.
i
r-UVAR Tech. Specs.
l 3.6.4.
Caaling Cooling shall be provided to prevent the surface temperature of an experiment to be irradiated from exceeding the boiling point of the reactor pool water.
3.6.5.
Precautions Experimental apparatus, material, or equipment to be inserted in the reactor, shall not be positioned so as to cause shadowing of the nuclear instmmentation, interference with the control rods, or other perturbations that may interfere with the safe operation of the reactor.
3.6.6.
Cahalt Facility The Co-60 pins possessed under the UVAR Operating License when used and stored in the UVAR pool shall be at distances greater than 5 feet from the operating UVAR reactor. Gamma irradiation facilities utilizing the Co-60 pins shall be designed to prevent physical damage to the Co-60 pins. When the Co-60 pins are in the pool, UVAR pool wa:er samples shall be subjected to gamma spectroscopy for the presence of Co-60 on a monthly frequency, (interval not to exceed six weeks) to assure that substantial leakage of Co-60 from the pins to reactor pool water does not occur.
Basra: (TS 3.6.1 - 3.6.5) The limitations on experiments specified in TS 3.6.1 through TS 3.6.5 are based on the irradiation program authorized by Amendment No. 3 to License No. R-66 dated August 13,1%2. The reactivity of less than 0.13$ that can be inserted or removed with the reactor in operation is to accommodate experiments in the rabbits.
(Co-60 Facility) When the Co-60 pins are in the UVAR pool they shall be kept a safe distance away from the UVAR reactor when it is operated, to avoid neutron activation and possible failure of the pin cladding, which may result in leakage of Co-60 to the reactor pool water. The Co-60 pins and the gamma irradiation facilities in which Aey are used will not be used in conjunction with the UVAR.
The monthly reactor pool water sampling frequency, adopted to monitor possible Co-60 leakage from the pins, is the same as that used in the U.S. AEC Safety Evaluation that was performed for these pins by the Division of Reactor Licensing on August 4,1971.
This is a reasonable frequency, for the mcst likely damage to the pins would be caused by cladding corrosion leading to pin holes. Co-60 leakage under these circumstances would proceed very slowly, into a large pool of water. Therefore, a monthly water sampling and analysis frequency should be adequate to indicate contamination levels before they become significant. UVAR poolwater need not be sampled and analyzed for Co-60 leakage if all Co-60 pins have been removed from the pool.
o UVAR Tech. Specs.
l l'
3.7.
. Oneratinn with Fualad Funarimante Annliemhiliev: This specification applies to the operation of the reactor with a fueled experiment within the reactor building.
Objective: The objective is to ensure that the confinement leak rate and fission product l
inventory in fueled experiments are within limits used in the safety analysis.
Specifications:
3.7.1.
Fualad Frnarinnante Ganaratine Power Above or Fanal to 1 W For fueled experiments in which the thermal power generated is gmater than or equal to I watt (W), the reactor shall not be operated unless the following conditions are satisfied:
(1) The experiment must be in the reactor pool and under at least 15 ft of water.
(2) The thermal power (or fission rate) generated in the experiment is not greater than 100 W (3.2 x 10i2 fissions /sec).
j i
(3) The calculated total energy produced by the experiment shall not exceed 600 W-years.
(4) The leak rate from the reacto room is not greater than 50% of containment of volume in
- 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> as measured within the previous 12 months.
3.7.2. - Fueled Funarirnanta Generatine Power Below I W Fueled' experiments in which the thermal power generated is less than 1 W (3.2 x 105 fissions /sec):
(1) May be located anywhere in the reactor building.
(2) The calculated total energy produced by the experiment shall not exceed 600 W-years.
Baans: In the event of the failure of a fueled experiment, with the subsequent release of
- fission products (100% noble gas,50% iodine,1 % solids), the 2-hour inhalation exposures to iodine and strontium 90 isotopes at the facility exclusion distance, 70 meters, are less than the limits set by 10 CFR 20, using an averaging period of 1 year.
The safety analyses for which results are used here are found in the SAR. The analysis suppoiting Specification 3.7.2 assumes 100% exfiltration of fission products from the reactor building in 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. The analysis supporting Specification 3.7.1 for the fueled experiments within the reactor pool assumes a fission product retention in the reactor j
room equivalent to 100% fission product exfiltration in 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br />. The specification provides suitable allowance for degradation between tests. The measurement of the i
exfiltration va! e is described in the SAR.
p UVAR Tech. Specs.
1 3.8.
Height of Water Above the Core in Natural Convection Mode of Ooeration Applicability: This specification applies to the height of water above the reactor core when j
the reactor is operating with natural convection cooling.
l Obiective: The objective is to ensure that there is a continuous path for circulation of water when the reactor is operated in the natural convection mode.
Specification: The reactor shall not be operated in the natural convection mode unless there is at least 1 ft of water above the core.
Bases: One foot of water above the core is sufficient to provide a continuous path for natural convection cooling. For other than zero power operation, the radiation levels may require a greater depth for shielding, in which case the regulations in 10 CFR 20 will govern.
(rest of page intentionally left blank) 4 l r
UVAR Tech. Specs.
3.9.
Rod Dron Times Aoolicabihtv: This specification applies to the time from the initiation of a scram to the time a rod starts to drop (magnet release time) as well as to the time it takes for a rod to drop from the fully withdrawn to the fully inserted position (free 4 rop time).
Objective: The objective is to ensure that the reactor can be shut down within a specified period of time.
Specification: The reactor will not be operated unless (1) the magnet release time for each I
of the three shim rods is less than 50 msec and (2) the free-drop time for each of the three shim rods is less than 700 msec.
Bases: Rod drop times as specified will ensure that the safety limit will not be exceeded in a short period transient. The analysis is given in the SAR.
l (rest of page intentionally left blank) l i-I l
l l
l UVAR Tech. Specs.
3.10.
Fmernency Removal of Decay Heat This TS has been deleted because the reactor core has been permanently unloaded. The emergency decay heat removal system is designed to only cool elements located on the gridplate. As fuel will never be placed on the gridplate again, this TS is no longer needed.
- (rest of page intentionally left blank) i I
i I
UVAR Tech. Specs.
3.11.
Primarv Coolant Condition Applienhility: Technical Specification 3.11 applies until all reactor fuel elements and Co-60 pins have been removed from the UVAR pool. Following their removal, TS 3.11 is not applicable during the permanent shutdown and decommissioning period. A substitute TS for this period is unnecessary. This specification applies to the quality of the primary coolant in contact with the fuel cladding.
Objectives The objectives are (1) to minimize the possibility for corrosion of the cladding on the fuel elements and (2) to minimize neutron activation of dissolved materials.
Specifications-3.11.1. Conductivitv If reactor fuel elements or cobalt-60 pins are present in the UVAR pool, the conductivity of the pool water shall be no higher than 5 x 104 mhos/cm.
{
3.11.2. Water pH If reactor fuel elements or cobalt-60 pins are present in the UVAR pool, the water pH of the poolwater shall be between 5.0 and 7.5.
Bases: A small rate of corrosion continuously occurs in a water-metal system. To limit this rate, and thereby extend the longevity and integrity of the fuel cladding, a water cleanup system is required. Experience with water quality control at many reactor facilities has shown that maintenance within the specified limits provides acceptable control.
By limiting the concentrations of dissolved materials in the water, the radioactivity of neutron activation products is limited. This is consistent with the as low as is reasonably achievable (ALARA) principle, and tends to decrease the inventory of radionuclides in j
the entire coolant system, which will decrease personnel exposures during maintenance and operations.
Following removal of all fuel elements and Co-60 pins from the pool, fuel cladding and j
Co-60 pin jacket corrosion due to improper poolwater conditions is no longer possible.
Also, activation of dissolved minerals in the poolwater cannot occur if the reactor does not operate. Consequently, primary water quality conditions can be relaxed and need not be specified in the Technical Specifications once all fuel element and cobalt pins are removed from the pool.
3.12 Poolwater-12 vel Manitoring Applicability: This specification applies to the poolwater-level float switch which monitors poolwater level and has alen and alarm functions.
Obiective: The goal is to prevent severe loss of poolwater level while cobalt pins are kept in storage in the UVAR pool Excessive loss of water level could result in diminished i
UVAR Tech. Specs.
shielding and generation of a radiation hazzard.
Enacifientlan Until all cobalt pins have been permanently removed from the UVAR pool, a poolwater level float switch shall be operating.
Basis: The water-level float switch is a simple device able to sense small decreases in poolwater level and perform timely local and remote alert and alarm functions.
(rest of page intentionally left blank) l 1
c l
UVAR Tech. Specs.
L l
4.0.
SURVEILLANCE REOUIREMENTS TS 4.1 through 4.3 and 4.5 through 4.7, and 4.9, have all been deleted. The justification l
for each deletion is given below. TS 4.4 has been modified with respect to its applicability.
4.1 This TS has been deleted because surveillance requirements on shim rod operation, rod drop l
times, reactivity measurements and rod physical condition either are not possible, necessary or appropriate if the reactor has been permanently and completely unloaded from the core gridplate.
4.2 This TS has been deleted because a reactor safety system only is necessary for an operating or operable reactor. Safety system channel tests, checks, calibrations, and a core heat balance either are not possible, necessary or appropriate if the reactor has been permanently and completely unloaded from the core gridplate.
4.3 This TS has been deleted because the emergency core spray system does not need to be checked and its flow rate measured if the reactor has been permanently and completely unloaded from the core gridplate.
4.4 The wording as to the applicability of this TS has been changed to recognize that once the reactor fuel has been completely removed from the Facility, and the Co-60 pins are no longer stored in the UVAR pool, an area radiation monitoring system will no longer be needed because it will then be impossible to generate very high radiation levels.
4.5 This TS has been revised at NRC request to insure that operation of the radiation monitors is verified after maintenance or modifications.
4.6 This TS has been deleted because surveillance of the reactor room closure equipment operability is not necessary or appropriate if the reactor has been permanently shut down and completely unloaded from the core gridplate. Fueled experiments cannot be run, and the fission product levels in the fuel are far below the levels in an operating reactor.
4.7 This TS has been deleted because surveillance of the airborne effluent monitor of the ventilation duct from the ground floor experimental area is not necessary or appropriate with the reactor permanently and completely defuelled. No experiments producing airborne effluents in association with the reactor can be run.
4.8 The wording to this TS has been modified, taking into account that it cannot be deleted until TS 3.11 no longer applies.
4.9 This TS has been deleted because secondary system coolant surveillance is not possible or needed if the reactor is permanently shut down. The surveillance relies on the regular production of Na-24 in the primary coolant by an operating reactor. At this time, all Na-24 has decayed away. Also, with the reactor shutdown a leak in the heat exchanger would result in secondary coolant flow into the primary coolant, and not the other way around as is the case when the reactor is being operated with the primary coolant pump on.
4.10 This TS has been added by NRC request to assure safe storage of cobalt in the UVAR pool.
l l
UVAR Tech. Specs.
4.4.
Area Radiation Manitnring Fnninment Annlienhility: TS 4.4 applies to the bridge radiation monitor referenced in Table 3.1. This TS will cease to apply once all UVAR fuel elements have been removed from the Reactor Facility and all Co40 pins have been taken from the UVAR pool for shielded storage elsewhere.
Objectives: The objectives are to ensure that the radiation monitoring equipment is operating and to verify appropriate alarm settings.
Enacification:
4.4.1 Daily Onershility Verification The operation of the radiation monitoring equipment and the position of their associated alarm set points shall be verified daily during periods when the reactor is in operation.
4.4.2.
Semianan=1 Calibratinn The calibration of the bridge radiation monitor referenced in Table 3.1 shall be performed semiannually until all fuel elements have been removed from the Reactor Facility and all Co40 pins have been taken from the UVAR pool for dry shielded storage or appropriate disposal.
Bases: haveillance of the monitoring equipment will provide assurance that sufficient warning of a potential radiation hazard is available.
4.5.
Maintenance Anr.lienhlity: This specification applies to the siirveillance requirements following i
maintenance of the area radiation monitoring system.
Obiective: The goal is to ensure that the area radiation monitoring system is operable following maintenance, repair or modification and prior to first use.
i Knacific=einn: Following maintenance, repair or modification of the area radiation monitoring system, it shall be verified that the system is operable before it is retuna to service.
Bases: It is necessary to ensure that any work on or change made to the system is carried out properly so that the system will operate as intended and that the system or component has been properly reinstalled or reconnected. Operability must be verified prior to the first use of the system following maintenance, repair or modification.
(rest of page intentionally left blank)
UVAR Tech. Specs.
4.8.
Primary Coolant Cnnditinna Annliemhilitv: This specification applies to the surveillance of primary water quality whenever either fuel elements and/or Co-60 pins are in storage in the UVAR pool.
Objective The objective is to ensure that water quality does not deteriorate over extended periods of time should the reactor not be operated and either fuel elements and/or Co-60 pins be in storage in the UVAR pool.
l l
Knacinentinn If the conductivity and pH of the primary coolant water is required to be maintained as per TS 3.11, then they shall be measured at least once every 2 weeks and l
verified to be as follows:
l Conductivity:
s 5 x 10-' mhos/cm pH:
between 5.0 and 7.5 Bascr Section 3.11 of these specifications ensures that the water quality is adequate during
)
reactor operation. This section ensures that water quality is adequate whenever either fuel elements and/or Co-60 pins are in the UVAR pool and the reactor is not operated.
4.10.
Surveillance of Ranctor Poolwater 12 vel Annlienhilitv: Technical Specification 4.10 applies until all Cobalt-60 pins have been removed from the UVAR pool. This TS specifies the surveillance frequency of poolwater level monitoring instrumentation.
Ohiective: The goal is to detect significant poolwater leak rates well before loss of poolwater results in rad!ation hazard due to cobalt stored in the pool.
Snarineniinn The poolwater level float switch shall be checked for operability, alarm and alert functions on a weekly basis until all cobalt pins have been removed permanently from the UVAR pool.
Banas: Poolwater is lost from the open UVAR pool by evaporation and small leaks. Makeup water is added about twice weekly, at which time the actual water level is checked and I
recorded.
l (rest of page intentionally left blank)
/
l !
y L
UVAR Tech. Specs.
5.0.
DESIGN FEATURES l
5.1.
Rametnr Fuel Rnacifie=*lann l
A_naliemhilitv These specifications apply to UVAR low enriched uranium (LEU) fuel.
Objective: The objective is to describe LEU fuel approved by the U.S. NRC for use in the i
UVAR.
Rnacifientinne; 5.1.1.
Fuel Material UVAR LEU fuel is of a type described for use at U.S. research reactors by the U.S.
Nuclear Regulatory Commission (NUREG-1313 " Safety Evaluation Report Related to the Evaluation of LEU Silicide Aluminum-Dispersed Fuel for Use in Non-Power Reactors"). The fuel meat is U Si dispersed in an aluminum matrix and enriched to less 3 2 than 20% U-235.
5.1.2.
Element Descrintinn
- (1) Plate-type elements of the MTR type are used. The fuel " meat" is clad with aluminum alloy to form flat fuel plates. The active length of the fuel region in the fuel plates is approximately 24 inches and the width is approximately 2.5 inches. The LEU fuel plates are joined at their long-side edges to two side plates. The entire fuel plate assembly is joined at the bottom to a cylindrical nose piece that fits into the UVAR core gridplate. The overall fuel element dimensions are approximately 3 inches by 3 inches by 36 inches. Each fuel plate contains 12.5 grams of U-235.
(2) " Standard" LEU fuel elements are composed of 22 parallel flat fuel plates each, and contain 275 grams of U-235.
(3) " Control-rod" LEU elements are similar to the standard elements, with the exception that they have half u many fuel plates (the 11 center plates being removed to form a channel which is bounded by 0.125 inch thick aluminum plates). Control-rod elements accommodate the control rods in the central channel. Their U-235 content is 137.5 grams.
(4) " Partial" LEU fuel elements are half-fueled elements composed of i1 LEU fuel plates and 11 unfuelled (dummy) plates. The U-235 content in these elements is 137.5 grams.
(5) "Special" LEU fuel elements have 22 fuel plates, of which 20 are removable. The l
maximum U-235 content in these elements is 275 grams and the minimum is 25 grams.
I
! L
f L
UVAR Tech. Specs.
L 5.1.3.
Core configurations A variety of UVAR core conDgurations may be used to accommodate experiments, but the loadings shall always be such that the minimum shutdown margin and excess reactivity specified in the UVAR Technical Specifications are not exceeded.
Basca: The NRC has described LEU silicide-fuel suitable for use in U.S. research reactors in NUREG-1313 " Safety Evaluation Report Related to the Evaluation of LEU Silicide Aluminum-Dispersed Fuel for Use in Non-Power Reactors," [$36.00, from NTIS, Springfield Va. (703-487-4650)]. Also, Bretscher and Snelgrove from the Argonne National Laboratory documented LEU fuel test results in AN11RERTR/TM-14, "The Whole-Core LEU U Si -Al Fuel Demonstration in the 30-MW Oak Ridge 3 2 Research Reactor." The LEU-SAR for the UVAR contains the safety analysis performed for the 22 flat-plate University of Virginia fuel elements. The LEU elements were designed by EG&G, Idaho, and are manufactured by the Babcock and Wilcox Company of Lynchburg, Virginia.
(rest of page intentionally left blank) l
UVAR Tech. Specs.
5.2.
Reactor Buildine TS 5.2 has been deleted, for the specifications en confinement, ventilation and reactor room free volume have been required to restrict leakage of radionuclides produced during reactor operation at power. The UVAR is no longer operated.
(rest of page intentionally left blank)
UVAR Tech. Specs.
5.3.
Fuel Use and Storage Anolicability: With the exception of Technical Specification 5.3.2, TS 5.3 applies until all reactor fuel elements have been removed from the UVAR Facility. Following their j
removal, TS 5.3 is not applicable during the permanent shutdown and decommissioning l
period. The specifications below apply to University of Virginia Reactor fuel used and/or l
stored at the University of Virginia Reactor Facility.
Obiective: The objective is to describe reactor fuel which may be used, possessed and/or stored at the University of Virginia Reactor Facility as well as measures that avoid nuclear criticality or fuel-related accidents.
Specifications:
5.3.1 LEU Pauaccion Limit A maximum of 4 kilograms of contained uranium-235 at less than 20% enrichment (which is defined as low enriched uranium, LEU) may be possessed at the Reactor Facility.
5.3.2.
Plutonium Pauauion Limit l
All plutonium contained in start-up sources, irradiation targets, flux foils and fission chambers, which totals less than 131 grams, is possessed at the Reactor Facility under the University's By-Product License and not the Reactor License.
5.3.3.
Storage Reactivity Limitation All reactor fuel elements, including fueled experiments and fuel devices not in the reactor, shall be stored in a geometric array where calculated k,is no greater than 0.9 for all conditions of moderation and reflection using light water, except in cases where an approved fuel shipping container is used, in which case flie fuel loading limitations specified in the certificate of compliance for the container snall apply.
l 5.3.4.
Storage Cooling Requirement Irradiated fuel elements and fueled devices shall be stored in an array that will permit sufficient natural convection cooling by water or air so that the fuel element or fueled device surface temperature will not exceed the boiling point of water.
Baher Section 5.4 of the American National Standard ANSI /ANS-15.1-1990, "The Development of Technical Specifications for Research Reactors," was used as the l
overall basis for the above specifications. The limit given in specification 5.3.1 is based on an estimated reasonable need for reactor fuel for use in the core and a spare fuel requirement determined by DOE's expected spare fuel manufacturing schedule. The specification in 5.3.2 is based on the unavoidable production of small amounts of plutonium in reactor fuel, sources, irradiation targets, flux foils and fission chambers, as a consequence of normal reactor operation. Precise amounts of plutonium produced, decayed or burned during reactor operation is hard to quantify, and this is not necessary for the small amounts of plutonium produced and contained in these aforementioned devices pose no undue reactor or radiation safety risks. )
c UVAR Tech. Specs.
6.0.
ADMINISTRATIVE CONTROLS g
6.1.
Orpnization Analic=hiliev: The specifications listed below in TS 6.1.1 through TS 6.1.4. apply to the organizational structure of the University of Virginia as it relates to the activities conducted at the Reactor Facility during the permanent shutdown and decommissioning period.
1 Ohiactive: The objective is to describe the chain of command having responsibility for the safe maintenance, defueling, decontamination and decommissioning of the Reactor Facility.
1 At the various administration levels, the functions, assignments, responsibilities and associated professional background, training and requalification requirements are listed, as applicable.
gn rific.einn.
6.1.1.
Structure The Reactor Facility shall be an integral part of the University of Virginia. The organizational structure of U.Va.. relating to the Reactor Facility is shown in Figure 6.1. The Vice President for Research and Public Service (level 1) shall have overall responsibility for management of the Facility.
The Reactor Decommissioning Committee Chair shall be responsible for advising the Reactor Director (Level 2) on all matters pertaining to the decommissioning and
- decontamination of the University of Virginia Reactor Facility. The decommissioning committee members may include reactor staff from level 3, and employees from the Office of Environmental Health and Safety.
6.1.2.
Da=_naanihility -
During the UVAR permanent shutdown and decommissioning period, the Reactor Facility Director (level 2) shall be responsible for overall facility operation and the direction of decommissioning activities at the Reactor Facility.
During periods when the Reactor Facility Director is absent, the Director's responsibilities are automatically delegated to the Reactor Supervisor (12 vel 3).
The Reactor Facility Director shall have at least a bachelor's degree in science or engineering and a minimum of 5 years of experience in the nuclear field. A graduate degree may fulfill 4 years of experience on a one-for-one time basis.
The Reactor Supervisor shall be responsible for the day-to-day activities at the UVAR and ensuring that these are conducted in a safe manner and within the limits prescribed
~ by the facility license. During periods when the Reactor Supervisor is absent, his responsibilities are delegated to a person at (level 4).
l l
p UVAR Tech. Specs.
The Reactor Supervisor shall have the equivalent of a bachelor's degree in science or engineering and at least 2 years of experience in Reactor Operations at this facility, or an equivalent facility, or at least 6 years of experience in Reactor Operations.
Equivalent education or experience may be substituted for a degree. Within nine months after being assigned to the position, the Reactor Supervisor shall obtain and maintain a NRC Senior Reactor Operator license if reactor fuel elements are still at the Facility. A NRC Senior Reactor Operator license, or a Reactor Operator license, is not required for level 3 and 4 personnel once all reactor fuel elements have been shipped offsite.
l l
6.1.3.
Staffing i
A licensed Senior Reactor Operator shall supervise any movement of reactor fuel. One l
or more health physicists, organizationally independent of the Reactor Staff as shown in l
Figure 6.1, shall be responsible for radiological safety at the Reactor Facility.
l 6.1.4.
Selectinn and Trainine of Perannnel The selection, training and requalification of Reactor Facility personnel snall follow the American National Standard for Selection and Training of Personnel for Research Reactors, ANSl/ANS-15.4-1988, Sections 4-6, to the extent applicable to the decommissioning status of the facility. The selected criteria for the personnel will be l
contained in the NRC-approved Operator Requalification Program, as amended.
Bases: Sections 6.1,6.1.1,6.1.2,6.1.3 and 6.1.4 of the American National Standard ANSI /ANS 15.1-1990 "The Development of Technical Specifications for Research l
Reactors," describe a generic and generally acceptable organizational structure for U.S.
research reactors.
They provide the bases for TS 6.1 above. Some of the ANSI standard recommendations apply to operable or operating reactor facilities, and are not necessarily valid for staff hired to perform decommissioning activities.
J (rest of page intentionally left blank)
UVAR Tech. Specs.
I 6.2 Radiatian hiatv. Danctor Safety and Ranctor Decommincionino Committees 6.2. A. Radiatian Safety Cammittee Aonlicabihtv: The specifications 6.2.A.1 and 6.2A.2 apply to the expert group who will provide oversight over the Reactor Safety and Reactor Dccommissioning Committees.
Obiective: To describe the makeup, responsibilities, and authority of the Radiation Safety Committee as regards reactor permanent shutdown and decommissioning.
Snecificarians:
6.2.A.I.
Camaanitian and Onnlifientian There shall be a Radiation Safety Committee (RaSC) to ensure that the Reactor Facility is shutdown and decommissioned in a safe manner within the terms of its reactor and other licenses, tractor Technical Specifications and NRC approved plans. The RaSC shall advise the Vice President and Provost and the Director of the Reactor Facility on safety and other
- concerns involving the decommissioning of the Reactor Facility.
The RaSC shall include its Chairman, the Radiation Safety Officer, the Director of the Reactor Facility, representatives of the hospital administration, Nuclear Medicine, and Radiological Physics or Radiation Oncology. Additional members may be drawn from such areas as
. Environmental Health and Ssfety, Radiology, Pathology, Biology, Nursing, Nuclear Engineering, Microbiology, Physics, Obstectrics and Gynecology. Membership of the RaSC l
will change as appointments are made by the Office of the President of the University.
However, the Radiation Safety Officer and the Reactor Director shall have standing
- appointments to the RaSC. Collectively, the RaSC members shall represent a broad spectrum of expertise in the radiological sciences. The membership of the Committee shall be such so as to maintain a high degree of technical proficiency in areas relating to radiation safety. The RaSC Chairman is the coordinator for all university licenses involving the use of radioactive materials and radiation producing equipment.
The Radiation Safety Committee is charged with ensuring that licensed material is used safely and in compliance with NRC regulations and institutional licenses. The RaSC reviews changes to the Broad Scope and other licenses. The RaSC also identifies program pwblems and recommends solutions and remedial actions. Some ofits functions are carried out through the use of subcommittees, such as the Reactor Safety Committee and the Reactor
. Decommissioning Committee. The RaSC will carry out most of its functions relating to the Reactor Facility through these two subcommittees.
6.2.A.2, RaSC Charter and Ruten (1) To establish a quorum, the ex-officio members and any 5 other Committee members must be present.
-(2) The Committee shall meet as often as necessary to conduct its business by not less than once in each calendar quarter.
n UVAR Tech. Specs.
l l
(3) The Committee shall have a written charter defining such matters as the authority of the Committee, the subjects within its purview, and other administrative provisions.
(4) Radiation Safety Committee meeting minutes shall be distributed to the committee membership within three months following a meeting. These minutes shall be reviewed i
for approval at the next scheduled committee meeting.
6.2.B.
Reactor Safety Committee l
Applicability: The specifications 6.2.B.1 through 6.2B.3 apply to the expert group who will provide specific reviews and audits of Reactor Facility operations while reactor fuel elements are on-site.
Obiective: To describe the makeup, responsibilities, and authority of the Reactor Safety
- Committee.
Specifications:
6.2.B l.
' Compositior and Onnlification l
There shall be a Reactor Safety Committee (Re SC) to review and audit reactor operations and ensure that the Reactor Facility is operated in a safe manner within the terms of the reactor license.- However, reactor safety concerns will end once all reactor fuel elements have been permanently shipped from the Reactor Facility. At that time the need for a Re SC shall cease, and any remaining radiation safety issues shall be referred to and be addressed by the University's Radiation Safety Committee. The Technical Specification requirement for a Reactor Safety Committee shall cease following the shipment of all reactor fuel elements off-site.
The Reactor Safety Committee shall be part (a subcommittee) of the Radiation Safety Committee (RaSC) and report to its Chairman, who is the coordinator for all licenses involving
- the use of radioactive materials and radiation producing equipment at the University of Virginia. The Reactor Safety Committee shall be composed of at least four members, and shall include the Radiation Safety Officer of the University and the Director of the Reactor Facility. The Reactor Director shall be the sole reactor staff representative on the Committee.
Collectively, the committee members shall represent a broad spectrum of expertise in the
- research-reactor field. The membership of the Committee shall be such so as to maintain a degree of technical proficiency in areas relating to reactor safety. The members may be drawn from within or outside the operating organization.
The ReSC shall advise the Vice President for Research and Public Service and the Director of i
the Reactor Facility on reactor safety concerns with the operation of the facility. ReSC reviews and audits are designed to uncover deficiencies that affect reactor safety.
6.2.B.2.
Charter and Rules
~(1) A quorum of the Committee shall consist of not less than the majority of the full committee. The Chair can designate another member from the Committee to preside in his absence.
l ;
1
y UVAR Tech. Specs.
l (2) The Committee shall meet at least semiannually and shall be on call by the Chair. Minutes of all meetings shall be disseminated as designated by the Chair.
(3) The Committee shall have a written charter defining such matters as the authority of the Conunittee, the subjects within its purview, and other administrative provisions as are required for effective functioning of the Committee.
(4) Reactor Safety Committee meeting minutes shall be distributed to the committee membership within three months following a meeting. These minutes shall be reviewed for approval at the next scheduled committee meeting.
6.2.B.3. Review and Audit Functions l
As a minimum the responsibilities of the Reactor Safety Committee include:
(1) Review and approval of untried experiments and tests that are significantly different from those previously used or tested in the reactor, as determined by the Facility Director.
(2) Review and approval of changes to the reactor core, reactor systems or design features that may affect the safety of the reactor.
(3) Review and approve all proposed amendments to the reactor license, Technical Specifications, and changes to the standard operating procedures (Note: SOPS are discussed in Section 6.3 of these specifications).
(4) Review reportable occurrences, to include violations of Technical Specifications, License or of Standard Operating Procedures that have safety significance, as well as the "l
occurrences listed in ANSI /ANS-15.1 Item 6.6.2. Also, to review the actions taken to j
identify and correct the cause of these occurrences.
(5) Review significant operating abnormalities or deviations from normal performance of facility equipment that affect reactor safety.
(6) Audit annually [through a selective yet comprehensive examination of records, logs and personnel]:
a) Facility operations for conformance to TS and License b) Results of actions taken to correct verified deficiencies that may occur in reactor equipment, systems, structures or method of operations that affect reactor safety.
... and audit biennially:
l c) Operator retraining and requalification program for the reactor operations staff d) Reactor Facility Emergency Plan and Implementing Procedures (7) Review and approval of changes to experiments, reactor systems and procedures as per 10 CFR 50.59. l l.
UVAR Tech. Specs.
Bass: American National Standard ANSI /ANS-15.1-1990 "The Development of Technical Specifications for Research Reactors," describes in Section 6.2 acceptable composition and qualification criteria for reactor safety committees and their review and audit functions.
Section 6.3 of the standard describes the organizational relationship of the group responsible for radiation safety to the reactor operations group. These sections of the standard are used as bases for the specifications listed above.
1 (rest of page intentionally left blank) l i
1 l
l
- 44 J
E l
l UVAR Tech. Specs.
l 6.2.C.
Reactor Decommissioning Committee Applicability: The specifications 6.2.C.1 through 6.2C.3 apply to the expert group who will have responsibility and oversight for decommissioning planning and execution activities at the Reactor Facility.
Obiective: To describe the makeup, responsibilities and authority of the Reactor Decommissioning Committee.
Specifications:
6.2.C. I.
Composition and Oualification There shall be a Reactor Decommissioning Committee (RDC) to plan the safe, legal and timely decommissioning of the Reactor Facility. Collectively, the decommissioning committee members shall represent a broad spectrum of expertise in the research-reactor and health-physics fields, with experience in reactor management, radiological safety, research reactor decommissioning and university administration. Committee members may be drawn from within or outside the University of Virginia, including subcontracted companies. The Committee shall be composed of at least four members, and shall include the Radiation Safety Officer of the University and the Director of the Reactor Facility.
The Reactor Decommissioning Committee shall be part (subcommittee) of the Radiation Safety Committee, which reports to the Vice President and Provost. The Decommissioning Committee shall advise the Reactor Director (Level 2) on all matters impacting the
. decommissioning of the Reactor Facility.
6.2.C.2.
Charter and Rules (1) A quorum of the Decommissioning Committee shall consist of not less than the majority of
]
the full committee. The RDC Chair can designate another member from the Committee to
]
preside in his absence.
(2) The Reactor Decommissioning Committee shall meet at least quarterly and shall be on call i
by the Chair. Meeting minutes shall be disseminated as per the RDC Charter.
(3) The Reactor Decommissioning Committee shall have a written charter defining such matters as the authority of the Committee, the subjects within its purview, and other administrative provisions as are required for effective functioning of the Committee.
(4) The Reactor Director shall cast a single vote in the name of the operations staff at Reactor Decommissioning Committee meetings. The operations staff encompasses the reactor staff, decommissioning subcontractors and anyone directly supporting decommissioning and working under the direction of the Reactor Director.
(5) Reactor Decommissioning Committee meeting minutes shall be distributed to the committee membership within three months following a meeting. These minutes shall be reviewed for approval at the next scheduled committee meeting.
l I
I L
f UVAR Tech. Specs.
(
6.2.C.3.
Decommissioning Coramittee Functions As a minimum, the responsibilities of the Reactor Decommissioning Committee following the l
termination of the Reactor Safety Committee shall include:
l (1) Review and approval for changes to the Reactor Facility and to the UVAR SOPS as applicable and described in 10 CFR 50.59.
1 (2) Review and approval of proposed changes to reactor licenses, Technical Specifications, NRC-approved plans (such as the Emergency and Security Plans), as well as the UVAR i
Standard Operating Procedures (SOPS), with the exception of changes to the organizational structure. [The responsibility and authority for the organizational structure for the Reactor i
Facility resides with the Vice President and Provost.]
(3) Review unusual and reportable occurrences, to include those violations of Technical Specifications, License, or of Standard Operating Procedures that have safety significance, as well as the occurrences listed in ANSI /ANS-15.1 Item 6.6.2. Also, to review the actions taken by reactor management to identify and correct the cause of these occurrences.
(4) Annually audit [through a selective, yet comprehensive, examination of records, logs and personnel] facility operations for conformance to licenses, Tecimical Specifications, NRC regulations and inspections, as well as UVAR SOPS; and to recommend remedial action to correct identified deficiencies.
(5) Biennially audit the Operator Retraining and Requalification Program of the reactor staff, as well as the Reactor Facility Emergency Plan and Implementing Procedures.
I I
(rest of page intentionally left blank) l 1,
l I
j L
c<h r
m 3 '"-
M.
M M
M O
O C
C G
G N
N RI I
I N
N AO O
I HI I
S S
M M.
C S
S I
I M
M M
M O
O M
M T
C C
O O
4 T tE S Y
Y C
C DO T
T E
E
)
RE E
D D
E I V I
F F
S O
T E
AA A
l I
I R
HS S
R P
C YS P
D N
N M
M TF E
O I
M M
LF C N I
O I
I A
T T
A A
O O
I D
I C
C C O V
I D
Y Y
AS A
A T
T FT R
R RE E
I F
F R N A
E I
H A A
TO RT M S
S C R R
E I
O O
AC A
L N
T T
HA E "A C E C
C I
G I
A A
R L R
,1 E
E
" L E
TI R
R N V 1 ARU EF 6 NAF I
OE L DO SY I
EI L
R UA U R S P R Y
O Z
F GI N T
S O
V I
F E
IL V
F F N A I
N R
I R)
A AI T I
C )2 E3 T )4 GNN U
O A PL L
I E S
TF L E
C E
E V
I I
TL L
CL VI R
DC(
O(
A(
H E
T A
E F
S C
S E
R O
T C R
A NI E
.O L
l E
R VT B)
I D
1 U
NR ISPL s
E E
l e
UO I
R & V n
I PHE R
i R
CL Y
E s l P
E R(
T C
F e
(
C I
A E
I F
n n VE F
F A
io F
T l i S
A E
S O
S t
R R &
Y S
g a O
T C
n c R
T H E
I ii S
t n O
l C T F
L Y
r u F
E A
H o m A
S RI E P
p m DH N
e o H
O r c R
I T
I T
L A
A V
I E
N D
H E
A R
A,
Chs H!6}e c
M.
M M
M M
M M
M O
O O
O T
C C
C C
NT E S Y
Y G
G DO T
T N
R N RE E
RI OI I
V IA A A
IAO CO
)
O F
F N
T N E
SE T
R R HS S
HI AIS YI S
P P C
C E S TS N
N I
RI S
E D I
N O
O M
M LF CI A T
T M
M C F I
I I
V I
D C
C F S A
A D
I O
O A O A
A E
E R
R D
"B C E L A
N R E I
" L L
G R
AR E O
G 1.N A R
Y GVI T
I NI S OE F S
6 U
EF L
V NR EI L i
I R)
DO RIC)
E3 IOO)
RTC L 2
4 I
O A T
UA U A L
SY TF L PL S C L ET E
C E
S I
L M T E F
R OE R E P R V
I TL I
L AI E
R DC(
O(
O N(
GN T VI E
T O
I A
C C
RGN N
S l
E E C U
TC R
A NI E
D OREM I
E L R
V B)
P ID 1
U FI E
E O H SP L
.S
& V R
s VR PHE R
e I
E CL Y
E n
N t
R(
T C
i F
CI A E
I F
s l U
I VE F
F A
t e
S A
F T
n n A
E S
O S
i o
(
Y S
l i R
R O
T C
t I
g a R
TH E
S n c O
CT F
L A
Y ii F
I E
H t n A
S R E P
r u DH N
o m I
H p m O
T e o I
L r c RI A
A T
VN DI E
H E
A R
.A
?-
UVAR Tech. Specs.
I 6.3.
Krandard Onerating PrncaAnres Annliemhility: The specification below concerns the procedural controls used to operate the University of Virginia Reactor (UVAR) and conduct experiments.
Objective The objective is the safe operation of the reactor in compliance with license conditions, federal regulations.
Knarificatinna:
6.3.1.
Items Covered by SOPS Written procedures, reviewed and approved by the Reactor Safety Committee shall be in effect and followed for the items listed below. These procedures shall be adequate to ensure the safe decommissioning of the reactor, bnt should not preclude the use of independent judgment and action should the situation require such.
1 (1) Stanup, operation and shutdown of the reactor.
(2) Installation or removal of fuel elements, control rods, experiments, and experimental facilities.
1 (3) Actions to be taken to correct specific and foreseen potential malfunctions of systems or components, including responses to alarms, suspected primary coolant system leaks, abnormal reactivity changes.
(4) Emergency conditions involving potential or actual release of radioactivity, including provisions for evacuation, re-entry, recovery, and medical suppon.
(5) Preventative and corrective maintenance operations that could have an effect on reactor safety.
(6) Periodic surveillance.
l (7) Radiation control.
6.3.2.
Changes to SOPS Changes that do not change the original intent of the procedures may be made with the approval of the Facility Director. All such minor changes shall be documented and subsequently reviewed by the Reactor Safety Committee (or by the Reactor Decommissioning Committee after the ReSC ceases to exist).
Basis: Section 6.4 of American National Standard ANSI /ANS 15.1-1990, "The Development of Technical Specifications for Research Reactors," suggests acceptable procedural controls to applied to operating U.S. research reactors.
l i t
I UVAR Tech. Specs.
i 6.4.
Review and Anoroval of Exneriments Anplicability: Specifications 6.4.1 through 6.4.6 listed below apply to classes of experiments run in the UVAR core, in the UVAR pool, or which use UVAR-generated neutron and/or gamma-radiation beams. However, a partial listing of examples of experimental work covered under experiment classes for which broad approval may have been obtained and, therefore, for which individualized experimental procedures would nol be required follows below:
(a) Samples to be irradiated in approved irradiation facilities, such as the neutron activation facilities, where the samples meet the criteria in TS 3.6 and TS 6.4.
(b) Samples to be irradiated in the neutron radiography facility beampon which are known not to be hazardous to reactor safety.
)
J Objective: The objective is the safe operation of the reactor and experiments, in accordance with license conditions and federal regulations. Experiments mn in conjunction with the reactor should not adversely affect reactor and radiation safety. Notwithstanding the regard for safety, the requirement for review and approval of experiments shall not limit the flexibility of experimenters performing work covered under general written procedures, or for which unanalyzed safety issues do not exist, as determined by the Reactor Director.
Specificatmns.
6.4.1.
Exnerimental Procedures and Melhads (1) Classes of experiments involving the UVAR, the UVAR pool or UVAR radiation beam facilities shall be carried out with established and approved written experimental procedures. The Reactor Safety Committee shall review all new classes of experiments prior to their initiation and approve written experimental procedures governing their operation.
(2) Written experimental methods that implement Reactor Safety Committee approved experimental procedures may be developed by the staff and/or experimenters, as needed.
Such experimental methods shall be approved by a Reactor Supervisor or the Reactor Director prior to use.
(3) The Rector Director or the Reactor Safety Committee shall decide whether an experimental procedure is required. Usually, an experimental procedure will not be required if the work in question is already covered under an existing approved general experimental procedure or by a Standard Operating Procedure.
6.4.2.
Reactivity limits As applicable, reactivity limits for experiments given in experimental procedures shall be based on analyses of maximum reactivity insertions that can be handled by the reactor or its control and safety systems without exceeding safety limits. Reactivity limits have been established in TS 3.6 Limitations on Exneriments for maximum absolute reactivity worth of individual experiments and the sum of the absolute values of the worth of all experiments.
f UVAR Tech. Specs.
6.4.3.
Matarlain As applicable, special requirements shall be established in the experimental procedures for significant amounts of special materials such as fissionable materials, explosives or metastable materials capable of significant energy release, or materials that are corrosive to reactor components or highly reactive with coolants. Requirements listed in experimental procedures may range from detailed analyses to double encapsulation and prototype testing.
l 6.4.4.
Failure and Malfunctions (1) Credible failures of any experiments shall not result in the release or exposures in excess of the annual limits established in Title 10, Code of Federal Regulations, Part 20.
(2) Experiments shall be designed such that they will not contribute to the failure of other experiments, core components, or principal physical barriers to uncontrolled release of radioactivity. Similarly, no reactor transient shall cause an experiment to fail in such a way as to contribute to an accident.
6.4.5.
Experimental Facility Rnecific LCO Limiting Conditions of Operation limits unique to an experiment shall be specified, as necessary, in the written experimental procedures. Specific surveillance activities which may be required for experiments will also be addressed in the experimental procedures.
l 6.4.6.
Deviations from Frnerimental Procedures l
(1) Changes to previously approved experiments and experimental procedures, determined l
by the Reactor Director to be substantive, shall be made only after review and approval l
by the Reactor Safety Committee.
(2) Minor changes to experimental procedures may be made with the approval of the Reactor Director, who will determine that no new reactor safety concerns exist, and l
with the approval of the Reactor Health Physicist, who will assure that radiological safety requirements can be met.
Bases: National Standard ANSI /ANS-15.1-1990, "The Development of Technical l
Specifications for Research Reactors," suggests acceptable provisions governing reactor-based experiments in sections 3.6 and 6.4. These sections served as bases for the above specification. In addition, examples are presented of activities involving the reactor which typically do not require individualized written procedures, because they are covered under a general procedure for an approved class of experiments, or covered by SOPS. It is unreasonable to require procedures with undue specificity when this would limit reasonable experimental flexibility and no unanalyzed safety issues exist. The Reactor Director has the resources and authority to determine when experimental procedures are required.
l l
f 1
UVAR Tech. Specs, l
6.5 Plant Operating Records Analtrabiliev: The specifications below apply to UVAR operating records.
Oh* active: The objective is to maintain and keep on file reactor operating records for future p
reference, and for demonstration of compliance with license conditions and federal regulations.
Specifications:
6.5.1.
Recnrds To Be Datalnad for at a==* Five Years l
In addition to the requirements of applicable regulations, records of the items listed below shall be kept in a manner convenient for review:
(1) Normal reactor facility operation (for example, reactor logbooks, reactor checklists and irradiation request forms).
(2) Principal reactor systems maintenance records.
(3) Reportable occurrences.
(4) Equipment and component surveillance activity required by Technical Specifications.
(5) Reactor Facility rJiation and contamination surveys.
(6) Experiments performed with the UVAR.
(7) Fuel inventories, transfers of radioactive material to and from the R-66 license.
(8) Approved changes to operating procedures.
(9) Records of meetings and audit reports of the Reactor Safety Committee.
(10) Records of meetings and audit reports of the Reactor Decommissioning Committee.
l 6.5.2.
Recorda To Be Ratninad for One Certifientinn Cvele Records of retraining and requalification of licensed operators shall be maintained at all times the individual is employed or until licensing is renewed.
(rest of page intentionally left blank)
) _
f l
UVAR Tech. Specs.
6.5.3.
Rerords To Be Da*=inaA for the Life of the Facility
?
In addition to the requirements of applica'. - regulations, records (or logs) of the items l
listed below shall be kept in a manner convenient for review and shall be retained as indicated:
(1) Gaseous and liquid radioactive effluents released from the Reactor Facility.
I (2) Off-site (radiological) environmental monitoring surveys.
(3) Radiation exposures for all personnel monitored at the Reactor Facility.
4 (4) Updated, corrected and as-built drawings of the Reactor Facility.
(5) Changes to reactor systems, components, or equipment that may affect reactor safety Basis: American National Standard ANSI /ANS-15.1-1990, "The Development of Technical Specifications for Research Reactors," provides record-keeping guidance in Section 6.8. This is the basis for the above specifications.
(rest of page intentionally left blank) x 1
l I
l l
4 i j f
e
UVAR Tech. Specs.
6.6.
R-ired Actinna Analie=hility: 'Ihe specifications below apply to instances where radiologically unsafe situations have been, or were likely to have been, generated.
Oblactive: The objective is to repon unsafe conditions, study their causes and consequences,l determine their effect on the health and safety of personnel and the public, and take
{
corrective action to prevent recurrence.
Specifications:
6.6.1.
Actinn To Be Taba in the Event of a Rananable Occurranca l
A reponable occurrence is any of the following conditions:
(1) An observed inadequacy in the implementation of either administrative or procedural controls, such that the inadequacy could have caused the existence or dewlopment of an unsafe condition at the Reactor Facility.
(2) Abnormal and significant degradation in reactor fuel, and/or cladding, coolant boundary,l or containment boundary (excluding minor leaks) where applicable that could result in exceeding prescribed radiation-exposure limits of personnel end/or environment.
(3) Major damage to the Cc-60 pins resulting in Co-60 concentrations in reactor pool water l in excess of 1 x 10-' micro-curier/ml.
In the event of a reponable occurrence, the following action shall be taken:
(a) Ongoing activities shall cease until the occurrence has been resolved.
l (b) The Director of the Reactor Facility or his designee shall be notified as soon as possible and corrective action taken as foreseen in the procedures.
(c) A written report of the occurrence shall be made which shallinclude an analysis of the l cause of the occurrence, the corrective action taken, and recommendations for measures to preclude or reduce the probability of reoccurrence. This report shall be submitted to the Director and the Reactor Safety Committee and/or the Radiation Safety Officer for review.
(d) A report shall be submitted to the Nuclear Regulatory Commission in accordence with l Section 6.7 of these specifications.
l-Banca: National Standard ANSI /ANS-15.1-1990, "The Development of Technical Specifications for Research Reactors," describes in sections 6.6 and 6.7 acceptable specifications for required actions related to safety limits violations, actions to be taken upon their discovery, and reporting requirements. These form the bases for the above specifications. -
L
UVAR Tech. Specs.
6.7.
Raaartine h-Irarnaa'=
Applicabilitv: The specifications 6.7.1 and 6.7.2 listed below apply to routine and special reports made by the University of Virginia Reactor Facility to the U.S. Nuclear Regulatory Commission.
q Ohiactive: The objective is to provide the licensing agency (NRC) with relevant information concerning normal and abnormal reactor operations which are necessary for the fulfillment of its mission to protect the public health and safety. A secondary objective is to comply with reporting requirements as given in the federal regulations.
Saacifientiaam: In addition to federal regulatory requirements (for example, follow 10 CFR i
20,30.50,40.60, and 70.50, as applicable), repons should be made to the U.S. Nuclear Regulatory Commission as follows:
6.7.1.
Danar'ine of Incidaa'=
(1) Immediate notification should be made by telephone, to the U.S. Nuclear Regulatory Commission Headquaners Operations Center of:
(a) Personnel total effective dose equivalent of 25 rem or more.
(b) The release of radioactive material, inside or outside of a restricted ares that results, or could result, over a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period, in personnel intake of 5 times the annual limit on intake specified in 10 CFR 20.
(2) A special report should be made by telephone as soon as possible, but no later than the next working day, to the U.S Nuclear Regulatory Commission Headquarters Operations Center of:
(a) Personnel exposures or releases of radioactive material greater than the limits in 10 CFR 20.
(b) Reportable occurrences as defined in Section 6.6.2 of ANSI /ANS-15.1.
l (c) Violation of a safety limit or technical specification.
l (3) A special written mpon should be sent by mail within 14 days to the U.S. Nuclear Regulatory Commission, Document Control Desk, Washington, D.C. 20555 (a) Accidental off-site miease of radioactivity above 10 CFR 20 limits, whether or not the release resulted in property damage, personal injury, or exposure.
(b) Reportable occurrence as defined in Section 6.6.2 of ANSI /ANS-15.1.
l (c) Violation of a safety limit or technical specification.
l UVAR Tech. Specs.
(4) A special written repon should be sent by mail within 30 days to the U.S. Nuclear Regulatory Commission, Document Control Desk, Washington, D.C. 20555, of:
(a) Accidental off-site release of radioactivity above 10CFR20 limits, whether or not the release resulted in propeny damage, personnel injury, or exposure.
(b) Reportable occurrence as defined in Section 6.6.2 of these specifications.
(c) Changes in personnel serving as Vice President For Research and Public Service, the Radiation Safety Committee Chair, Reactor Decommissioning Committee Chairman, Reactor Safety Committee Chair, Reactor Facility Director, or Reactor Supervisor.
(5) A written repon should be sent within nine months after initial criticality of the reactor or within 90 days of completion of the stanup test programs, whichever is earlier, to the U.S. Nuclear Regulatory Commission, Document Control Desk, Washington, D.C.
20555, upon receipt of a new facility license, an amendment to the license authorizing an increase in power level or the installation of a new core with fuel elements of a design different design than previously used. The report will include the measured values of the operating conditions or characteristics of the reactor under the new conditions, including:
(a) Total control rod reactivity wonh.
(b) Reactivity wonh of the single control rod of highest reactivity wonh.
(c) Minimum shutdown margin both at ambient and operating temperatures.
J 6.7.2.
Rautine Ananal Ranarts A routine annual report will be made by March 31 of each year on decommissioning and related activities completed during the previous calendar year. The repon should be sent to the U.S. Nuclear Regulatory Commission, Document Control Desk, Washington, D.C. 20555, providing the following information:
(1) Reactor Facility utilization, (2) Description of university staff assigned to decommissioning: numbers, background and responsibilities, (3) TS compliance and reponable events, (4) Results of NRC inspections and licensing actions, (5) Summary report on RDC meetings and audit findings, (6) Health Physics Program (7) Annual waste content and volume shipped, (8) Summary of the nature and amount of radioactive solid, liquid and airborne effluents released or discharged to the environs beyond the effective control of the licensee, as measured or calculated at or prior to the point of such release or discharge, I
(9) Results of environmental surveys and sampling outside the Reaccor Facility, 1
UVAR Tech. Specs.
(10)
Reactor Facility personnel and visitor radiation exposure summary report, including the dates and times of significant exposures (greater than 500 mrem for adults and 50 mrem for persons under 18 years of age),
(11)
Summary of radiation and contamination surveys performed within the Reactor i
- Facility, (12)
Status of decommissioning funding and expenditures, (13)
Description of contractor companies operating on-site, (14)
Summary of contracted tasks and timelines, (15)
Significant Changes to the Reactor Facility, Reactor SOPS and of all changes made per 10 CFR 50.59, (16)
Summary of large equipment transfers, (17)
New and modified SOPS having radiation safety significance, (18).
Status of emergency preparedness, (19)
Figures on industrial accidents or incidents.
l (rest of page intentionally left blank) J
i Proposed Version, with no vertical lines in right margin to indicate changes APPENDIX A TECHNICAL SPECIFICATIONS FOR THE UNIVERSITY OF VIRGINIA REACTOR FACILITY LICENSE No. R-66 DOCKET No. 50-62 As Revised to Facilitate Permanent Reactor Shutdown, Decontamination and Decommissioning August 3,1999
n l
UVAR Tech. Specs.
TABLE OF CONTENTS East 1.0.
DEFINITIONS.......................................... 3 Figure 1.1 Reactor Facility Boundary Area:,................... 10 2.0.
SAFETY LIMIT AND LIMITING SAFETY SYSTEMS SETTINGS........ I1 2.1.
Safety Limit.......................................
1 1 l
2.2.
Limiting Safety System Settings..........................
15 3.0.
LIMITING CONDITIONS FOR OPERATION.....................
16 3.1.
- Reactivity........................................
16 3.2.
Reactor Safety System................................
18
,3.3.
Reactor Instrumentation...............................
20 3.4.
Radioactive Effluents.................................
22 3.5.
Confinement
....-..................................23
-3.6..
Limitations on Experiments.............................
24 3.7.
Operation with Fueled Ex},criments
.......................26 3.8.
Height of Water Above the Core in Naiural Convection l
Mode of 0peration....................................
27 3.9.
Rod-Drop Times.....................................
28 3.10.
Emergency Removal of Decay Heat (deleted).................
29 i
3.11.
Primary Coolant Condition.............................
30 4.0.- - SURVEILLANCE REQUIREMENTS...........................
32 4.1.
Shim Rods (Deleted)..................................
32 l
4.2.
Reactor Safety System (Deleted)..........................
32 4.3.
Emergency Core Spray System (Deleted)....................
32 4.4.
Area Radiation Monitoring Equipment......................
33 L
4.5.
Maintenance (Deleted)................................
33 l
l 4.6.
Confinement (Deleted)................................
32 4.7.
Airborne Effluents (Deleted)...........................
32 4.8.
Primary Coolant Conditions
............................34 4.9 Surveillance of Activity in Secondary System (Deleted)...........
32 4.10' Surveillance of Reactor Poolwater Level
....................34 l
5.0.
DESIGN FEATURES.....................................
35 5.1.
Reactor Fuel Specifications.............................
35 5.2.
Reactor Building (Deleted).............................
37 5.3.
Fuel Use and Storage.............,...................
3 8 6.0.
' DMINISTRATIVE CONTROLS.............................
39 A
6.1.
Organization......................................
3 9 6.2.
Radiation Safety, Reactor Safety & Reactor Decommissioning Committees 41 6.3.
Standard Operating Procedures
..........................49 6.4.
Review and Approval of Experiments......................
50 6.5.
Plant Operating Records................................
52
'6.6.
- Required Actions....................................
54 6.7.
Reporting Requirements...............................
55 UVAR Tech. Specs.
1.0.
DEFINITIONS Administrative Controls: Administrative controls are those organizational and procedural requirements that are established by the reactor licensee management.
Applicability: As regards use of this term in the Technical Specifications, it is a statement that indicates which components are involved.
Basis: As regards use of this term in the Technical Specifications, it is a statement that provides the background or reason for the choice of specification (s), or references a particular portion of the Safety Analysis Report (SAR) that does.
Beamnorts: The beamports are the two 8-inch diameter neutron beamports that penetrate the shield on the south side of the UVAR pool.
Channel: A channel is the combination of sensor, line, amplifier, and output devices which are connected for the purpose of measuring the value of a parameter. (Also, see definition for measuring channel).
Channel Calibration: A ci annel calibration is an adjustment of the channel such that its output corresponds with acceptable range and accuracy tc, known input values of the parameter which the channel measures. Calibration shall encompass the entire channel, including equipment actuation, alarm, or trip and shall be deemed to include a channel test.
Channel Check: A channel check is a qualitative verification of acceptable performance by observation of channel behavior, or comparison of the channel with other independent channels or systems measuring the same variable, where this capability exists.
Channel Test: A channel test is the introduction of a signal into a channel to verify that it is operable.
Confinement: Confinement means a closure on the overall facility that controls the movement of air into it and out through a controlled path.
Decommissioning: Decommissioning means to remove a facility or site safely from service I
and reduce residual radioactivity to a level that permits: (1) release of the property for l
unrestricted use and termination of the license; or (2) release of the property under restricted conditions and termination of the license (10CFR50.2). Decommissioning does not include storage or removal of fuel, or non-radiological demolition activities.
l Decontamination: Decontamination are the activities employed to reduce the levels of radioactive and/or hazardous contamination in or on material, structures and equipment.
Design Features: The definition for design features is as defined in 10 CFR 50.36.
Excess Reactivily: Excess reactivity is that amount of reactivity that would exist if all reactivity control devices were moved to the maximum reactive condition from the point I
where the reactor is exactly critical (km = 1).
UVAR Tech. Specs.
Exneriment: Any operation, hardware, or target (excluding devices such as detectors, foils, activation samples in an irradiation facility, etc...) that is designed to investigate non-routine reactor characteristics or that is intended for reactor irradiation within the UVAR pool, on or in the beamport or irradiation facility, and that is not rigidly secured to a core or shield structure so as to be a part of their design.
Funerimental Facility: An experimental facility is a structure or device associated with the reactor that is intended to guide, orient, position, manipulate, or otherwise facilitate a multiplicity of experiments of similar character.
Exnerimental Methods: Experimental Methods are written and approved instructions which provide guidance to the reactor staff or experimenters for the completion of tasks specified in Experimental Procedures (EPs). While EPs, and changes thereto, are reviewed and approved by the Reactor Safety Committee (RSC), experimental methods are written and reviewed by reactor staff and/or experimenters and approved by a reactor supervisor or administrator, Newly developed experimental methods or changes to existing experimental methods should be sent to the RSC as information items.
Exnerimental Procadnres: Written procedures reviewed and approved by the Reactor Safety Committee which describe the manner in which experiments are run in conjunction with the UVAR, to assure reactor and radiological safety. Operational limits peculiar to the experiment are included in these procedures. Detailed implementation of experimental procedures may be made through the use of experimental methods.
Explosive Material: Explosive material is a solid or liquid that is categorized as a Severe, Dangerous, or Very Dangerous Explosion Hazard in " Dangerous Properties of Industrial Materials" by N.I. Sax, or is given an Identification of Reactivity (Stability) index 2,3, or 4 by the National Fire Protection Association in its publication 704-M, " Identification System for Fire Hazards of Materials," also enumerated in the " Handbook for Laboratory Safety" published by the Chemical Rubber Co.
Forced Convection Mode: The reactor is in the Forced Convection Mode when the flow header is up and the primary pump is operating.
Fueled Exneriment: A fueled experiment is an experiment that contains U-235, U-233 or Pu-239 in levels exceeding trace quantities. Reactor fuel elements are not included in this definition. (Also, see the definition for trace auantities and TS 3.7.).
Imnortant Process Variables: Important process variables are measurable parameters that individually or in combination reflect the basic physical <.,ondition of physical barriers. They may include fuel temperature, reactor power, reactor coolant flow rate, reactor coolant inlet or outlet temperature, pool level, or coolant pressure. (Also, see definition for safety limits)
Imrge Access Facilities: The large access facilities are the two large openings approximately 5 ft wide by 6 ft high that penetrate the shield on the south side of the UVAR pool.
Licensed Operator: A licensed operator is an individual authorized by the U.S. Nuclear Regulatory Commission to carry out the duties and responsibilities associated with operation of the UVAR. (Also, see definitions for Senior Reactor Onerator and Reactor Onerator).
UVAR Tech. Specs.
Limiting Conditions for Ooerations: Limiting Conditions of Operation (LCOs) are those administratively established constraints on equipment and operational characteristics that shall be adhered to during operation of the facility. The LCOs are the lowest functional capability or performance level required for safe operation of the reactor.
Limiting Safety System Settings: Limiting Safety System Settings (LSSS) are those limiting values for settings of the safety channels by which point protective action must be initiated.
The LSSS are chosen so that automatic protective action will terminate the abnormal situation before a safety limit is reached. The calculation of the LSSS shall include the process uncertainty, the overall measure nent tincertainty, and transient phenomena of the process instrumentation. To achieve operational flexibility, it is recommended that actual trip points, where possible, be set more conservatively than specification values.
Measured Value: The measured value of a parameter is the value of the variable as it appears on the output of a measuring channel.
Measuring Channel: A measuring channel is the combinatica of sensor, line, amplifier, and output devices which are connected for the purpose of measuring the value of a parameter.
1 (Also, see definition for channel).
Methods: Methods are written and approved instructions which provide guidance to the reactor staff, and/or subcontractors working for reactor management, for the completien of tasks specified in Standard Operating Procedures (SOP's). While SOP's, and changes thereto, are reviewed and approved by the UVAR Decommissioning Committee (UDC),
methods are written and reviewed by the reactor staff and/or subcontractors working for reactor management, and approved by the reactor supervisor or reactor director. Newly developed methods, or changes to existing methods, should be sent to the UDC as information items.
Movable Exneriment: A movable experiment is one where it is intended that all or part of the experiment may be inserted, removed, or manipulated in or near the core while the reactor is critical.
Natural Convection Mode: The reactor is in the Natural Convection Mode when the flow through the core is maintained by the buoyancy forces associated with the water being heated by the reactor.
Obiective: As regards use of this term in the Technical Specifications, it is a statement that indicates the purpose of the specifications.
On Call: To be on call refers to an individual who (1) has been specifically designated and the designation is known to the operator on duty, (2) keeps the operator on duty informed of l
where he may be contacted and the phone number, and (3) is capable of getting to the Reactor Facility within a reasonable time under normal conditions (e.g., approximately 30 min).
Onerable: A component or system is operable when it is capable of performing its intended function in a normal manner. i 1
i l
l l
o UVAR Tech. Specs.
l-l Operating: A component or system is operating when it is performing its intended function in a normal manner.
Protective Actian:' Protective action is the initiation of a signal or the operation of equipment within the reactor safety system in response to a variable or condition of the reactor having reached a specific limit.
(1) channel level. At the protective instrument channel level, protective action is the generation and transmission of a trip signal indicating that a reactor variable has reached a specified limit.
~ (2) muhavetem level. At the protective instrument subsystem level, protective action is the generation and transmission of a trip signal indicating that a specified limit has been reached.
NOTE: Protective action at this level would lead to the operation of the safety shutdown equipment to immediately shut down the reactor.
-(3) instrument svetem level. At the protective instrument system level, protective action is the generation and transmission of the command signal for the safety shutdown equipment to operate.
(4) safety svetem level. At the reactor safety system level, protective action is the operation of sufficient equipment to immedia:tely shut down the reactor.
Penenar Facility: Reactor Facility refers to the immediate site-area surrounding and including the reactor building which houses the University of Virginia Reactor (UVAR).
The site boundary is demarcated by a chain link fence and gates. (See Figure 1.1)
Reactivity I imita: Reactivity limits for experiments are quantities referenced to an average pool temperature of <90* F with the effect of xenon poisoning on core reactivity accounted for if greater than or equal to 0.07$. The reactivity worth of samarium in the core will not be included in reactivity limits. The reference core condition will be known as the cold, xenon-free critical condition.
Reactivity Worth of an Exneriment: The reactivity worth of an experiment is the value of the reactivity change that results from the experiment being inserted into or removed from its intended position.
i Reactor Operatino: The reactor is operatirag whenever it is not secured or shutdown.
Esassor Oneratian: The reactor is in operation when not all of the shim rods are fully inserted and six or more fuel elements are loaded in the grid plate.
l i
l Reactor Operator: An NRC-licensed reactor operator is an individual who is certified by the l
NRC and the reactor administration to manipulate the controls of the UVAR reactor.
L e
UVAR Tech. Specs.
Reactor Safety Systems: Reactor safety systems are those systems, including their associated input channels, which are designed to initiate automatic reactor protection or to provide information for initiation of manual protective action.
Reactor Secured:- The reactor is secured when:
~
l (1) Either there is insufficient moderator available in the reactor to attain criticality or there is insufficient fissile material present in the reactor to attain criticality under optimum available conditions of moderation and reflection, or (2) The following conditions exits:
a.
All shim rods are fully inserted,
- b. The console key is in the OFF position and is removed from the lock, and c.
No work is in progress involving core fuel, core structure, installed control rods, or control rod drives unless they are physically decoupled from the control rods, and
. d.
No experiments are being moved or serviced that have, on movement, a reactivity worth exceeding the maximum reactivity value allowed for a single experiment, or one dollar, whichever is smaller.
l Reactor Shutdown: The reactor is shut down if it is suberitical by at least one dollar in the l
reference core condition with the reactivity worth of all installed experiments included.
Permanent Reactor Shutdown: A reactor is in a permanent shutdown state when all reactor l
fuel elements have been removed from the reactor gridplate and an administrative order is in place to prevent a reloading of the core.
I j
Reactor Staff: The Reactor Director and all personnel administratively reporting to him.
Reference Core Condition: The condition of the core when it is at ambient temperature (cold) and the reactivity worth of xenon is negligible (<0.30$).
Regulatmg Rod: The regulating rod is a control rod oflow reactivity worth fabricated from stainless steel and used primarily to maintain an intended power level. The regulating rod need not have scram capability. The rod may be controlled by the operator with a manual switch or by the automatic servo-controller.
Reportable Occurrence: A reportable occurrence is any of the conditions described in Section 6.6.2 of these specifications.
Research Reactor: A research reactor is defined as a device designed to support a self-sustaining neutron chain reaction for research, development, education, training, or experimental purposes, and that may have provisions for the production of radioisotopes.
Safety Limits: Safety Limits are limits on important process variables that are found to be
. necessary to reasonably protect the integrity of the principal physical barriers that guard against the uncontrolled release of radioactivity. The principal physical barrier is often the fuel cladding. (Also, see the definition for imnortant nre== variables). u
f l
UVAR Tech. Specs.
Scram Time: Scram time is the elapsed time between the initiation of a scram signal and a specified movement of a control or safety device.
Secured Experiment: A secured experiment is an experiment, experiment facility, or component of an experiment that is held in a stationary position relative to the reactor by mechanical means. The restraining forces must be substantially greater than those to which the experiment might be subjected by hydraulic, pneumatic, buoyant, or other forces that are normal to the operating environment of the experiment or by forces that can arise as a result of credible malfunctions.
Senior Reactor Ooerator: An NRC-licensed senior reactor operator is an individual who is certified by the NRC and the reactor administration to manipulate the controls of the UVAR reactor and to direct the activities of reactor operators.
Shall. should and may: The word "shall" is used to denote a requirement; the word "should" to denote a recommendation; and the word "may" to denote permission, neither a requirement nor a recommendation.
Shim Rod: A shim rod is a control rod fabricated from borated stainless steel, which is used to compensate for fuel burnup, temperature, and poison effects. A shim rod is magnetically coupled to its drive unit allowing it to perform the function of a safety rod when the magnet is de-energized. (Also, see definition for regulating rod).
Shutdown Margin: Shutdown margin is the minimum shutdown reactivity necessary to provide confidence that the reactor can be made suberitical by means of the control and safety systems starting from any permissible operating condition and with the regulating rod and the most reactive shim rod in their most reactive position, and that the reactor will remain suberitical without further operator action.
Snecification(s): As regards use of this term in the Technical Specifications, it is a statement that provides specific data, conditions, or limitaticas that bound a system or operation. This statement is the most important statement in the technical specifications agreement. Only the specifications statements are governing.
Standard Operating Procedures: Written procedures reviewed and approved by the Reactor Safety Committee to assure reactor safety and compliance with federal regulations, which describe the manner by which the reactor staff will operate and maintain the UVAR. (Also, see TS 6.3).
Surveillance Requirements: The definition for surveillance requirements is as defined in 10 CFR 50.36.
I Surveillance Time Intervals:
Annually (interval not to exceed 15 months)
Semiannually (interval not to exceed 71/2 months)
Quarterly (interval not to exceed 4 months)
Monthly (interval not to exceed 6 weeks)
Weekly (interval not to exceed 10 days)
Daily (must be done during the calendar day)
I <
UVAR Tech. Specs.
Trace Ouantities: As related to fissionable or fissile nuclides such as U-235, U-233 or Th-232 potentially present in environmental samples on which neutron activation analysis may be attempted, trace quantities are taken to be negligibly-small concentration levels below 100 parts-per-million (ppm). (Also, see the definition for Fueled Experiment).
Tried Experiment: A tried experiment is (1) an experiment previously performed in the UVAR or (2) an experiment for which the size, shape, composition, and location does not differ significantly enough from an experiment previously performed in the UVAR to affect reactor safety.
True Value: The true value is the actual value of a parameter.
Unscheduled ShutdmYD: An unscheduled shutdown is defined as any unplanned shutdown of the reactor caused by the actuation of the reactor safety system, operator error, equipment malfunction, or manual shutdown in response to conditions that cculd adversely affect safe operation, not including shutdowns that occur during testing nor check-out operations.
(rest of page intentionally left blank) i l
l I
l
- g Hb y'.
q s
N
\\
"/ '.Q\\,
w/'p /,l/,
N w
,X
/$
N N%
m
/j N
.s'
+sff' x
J j'
N.
s w/,-l[l,\\
j.
a
/ f/
ni
\\
i c
'a j
s v w.= -
n i
j/.
)
r x
wr,'li
\\
f, \\
, /,
o
=
/
t x
i i Ce= m-y x
i s
x )t l
.n%
e
[.
i a
l0,l h e t
f t f 1
v i
n w0 0
. u d7 I
ef l /
[ ', ' -
//z l
tao c
wJ r n
/'
N, ao mi
_ J
_7' t
e a d v e
rl ee ten
~
ma i t rm 3'
pW r a e
C ~~ ~
_,}
e' d1
~
R 3
isn8 l
M O
i 7
a
.,G
'h:
C At s
1 e e rd R"
/,#
g
. C_ /_ @,
u r
Tjr o
/
(i e
0' A
t g
ca yn E
it o l-y:,f'd lc R
l l
a' s._ ~ _
i
/
r s
cN M
/
a
. ~ ~
e lN F"0
~
u
~
r
$=
~
3 N
o'
~ _3 7 t
~-
c2 a8
~
e
~
3
~
R
' c
~L -
e rd
/
~
a u ct
~_i Y
1 i ct u a L
N(
/ ' /j /
/
, f. _,_~~~,{-
1
~..
j g ~ =._.
1 e
4._
r u
g
/
/,A_3'~~.
F i
_ ' 7,
(.
't 7
f Nl
/
[-
d_
,/
f x /-M.i.
E l{
g-ll
/ [f/
~
4 f
t UVAR Tech. Specs.
2.0.
SAFETY LIMIT AND LIMITING SAFETY SYSTEM SETTINGS 2.1.
Saferv Limits 2.1.1.
Safety Limits in Forced Convection Mode of Operation Applicability: This specification applies to the interrelated variables associated with core thermal and hydraulic performance in the forced convection mode of operation.
These variables are:
P = Reactor thermal power W = Reactor coolant flow rate Ti = Reactor coolant inlet temperature L = Ileight of water above the core Obiective: The objective is to ensure that the integrity of the fuel clad is maintained.
Specification: In the forced convection mode of operation:
(1) The pool water level shall not be less than 19 ft above the top of the core.
(2) The reactor coolant inlet temperature shall not be greater than Ill'F.
(3) The true value of reactor coolant flow shall not be below 575 gpm.
(4) The combination of true values of reactor core power and reactor coolant flow shall be below the line defined by:
P = 0.24 + (4.5 x 10-3
- W) i P = 0 for W < 575; P in MW, W in gpm The allowed region of operation is shown by the unshaded region of Figure 2.1.
Basis: Above 575 gpm in the region of full power operation, the criterion used to establish the safety limit was a burnout ratio of 1.49 including the worst variation in the manufacturer's tolerance and specification, hot channel factors and other appropriate uncertainties. The analysis is given in the LEU SAR.
Below 575 gpm buoyancy forces competing with forced convection may lead to flow instabilities in some of the channels and is therefore not allowed. The analysis of the loss of flow transient shows that during the transition from forced convection to natural convection following a loss of flow and reactor scram that the fuel temperature is well below the temperature at which fuel clad damage could occur, j L-
gr -
I t>
1 l
t I
t i
i i
F l
l t
i I
i I
t i
i l
I i
l 1
j l
i l
l
\\
1 r-UVAR Tech. Specs.
2.1.2.
Safety Limits in the Natural Convection Mode of Operation Applicability: This specification applies to the interrelated variables associated with core thermal and hydraulic performance in the natural convection mode of operation.
These variables are:
P = Reactor thermal power T = Reactor coolant inlet temperature i
Obiective: The objective is to ensure that the integrity of the fuel clad is maintained.
Specification: In the natural convection mode of operation:
(1) The true value of reactor power shall not exceed 750 kW.
(2) The reactor coolant inlet temperature shall not be greater than Ill*F.
Basis The criterion for establishing a safety limit with natural convection flow is established as a fuel plate temperature. The analysis for natural convection flow shows that at 750 kW, the maximum fuel plate temperature is well below the temperature at which fuel clad damage could occur.
(rest of page intentionally left blank) l 4
i l L
r UVAR Tech. Specs.
2.1.3.
Safety Limit for the Transition from Forced to Natural Convection Mode of Operation Applicability: This specification applies to the condition when the reactor is in transition from forced convection flow to natural convection flow.
Obiective: The objective is to ensure that the integrity of the fuel clad is maintained.
Specification: The current to the control rod magnets must be off when the reactor is 1
making a transition from forced to natural convection.
Basis: The safety analysis of the loss of coolant transient demonstrates that the fuel plate temperature is maintained well below the temperature at which fuel clad damage could occur during the transition from forced downflow through flow reversal to the establishment of natural convection provided that the loss of flow transient is accompanied by a scram.
(rest of page intentionally left blank) i l
{
l UVAR Tech. Specs.
1 2.2.
Limiting Safety System Settings Applicability: These specifications apply to the set points for the safety channels monitoring reactor thermal power, coolant flow rate, reactor coolant inlet temperature, and the height of water above the core.
Objective: The objective is to ensure that auiomatic protective action is initiated to prevent the safety limit from being exceeded.
Specifications:
2.2.1.
Forced Convection Mods For operation in the forced convection mode, the limiting safety system settings shall be:
Reactor Thermal Power 3.0 MWt (max)
=
Reactor Coolant Flow Rate 900 gpm (min)
=
Reactor Coolant inlet Temperature 108"F (max)
=
lleight of Water above Core 19' 2" (min)
=
Reactor Period 3.3sec (min)
=
2.2.2.
Natural Convection Mode I
For operation in the natural convection mode, the limiting safety system settings shall be:
Reactor Power 300 kWt (max)
=
Reactor Coolant Inlet Temperature 108'F (max)
=
Reactor Period 3.3 sec (min)
=
Bases The analysis in the LEU SAR shows there is sufficient margin between these settings and the safety limit under the most adverse conditions of operation:
(2.2.1.) For the forced convection mode, the LEU SAR considers accidents with reactor power at 3.45 MW, a period of 3 seconds, pool inlet temperature of 11l'F and a coolant flow of 837 gpm. The maximum fuel plate temperature calculated was considerably below j
the aluminum clad melting point. The LSSS specified above for this mode of operation are more conservative than the parameters used in the LEU SAR analysis.
(2.2.2.) With natural convection flow, there is no minimum coolant flow rate and no minimum height of water above the core so long as there is a path for flow (see Section 3.8 of these specifications). The LEU SAR shows that the maximum fuel plate temperature under natural convection with initial power of 750 kW and pool inlet temperature of 11l'F was well below the aluminum clad melting point. The LSSS specified above for this mode of operation are below the analyzed condition.
y UVAR Tech. Specs.
3.0.
LIMITING CONDITIONS FOR OPERATION 1:
- 3.1.
' Daac'ivity -
'Annliemhility: This specifiEation applies to the reactivity condition of the reactor and the -
reactivity worth of control rods and experiments.
Obiectives: The objectives are to ensure that the tractor can be shut down at all times and t
i
. that the safety limit will not be exceeded.
Specification: The reactor shall not be operated at powers in excess of 1 kW unless the following conditions exist:
(1) The minimum shutdown margin provided by shim rods, with secured experiments (see Section 1.0) in place and referred to the cold, xenon-free condition with the highest-worth shim rod and the regulating rod fully withdrawn, is greater than 0.55$.
(2) An experiment with a reactivity worth greater than 0.60$ must be a secured experiment.
. (3) The total reactivity worth of the two experiments having the highest reactivity worth is less than 2.00$.
(4) The total reactivity worth of all experiments is less than 2.50$.
(5) The maximum excess reactivity with fixed experiments in place and referred to cold, xenon-free condition shall be limited to 6.50$.
Bama: Operation of the reactor at power levels below I kW to measure the reactivity worth of untried experiments, and to measure the excess reactivity of new core loadings, is allowed with procedures approved by the Reactor Safety Committee. Reactivity is measured in dollars from the reactor period, and as such is the quantity of safety significance. Reactivity limits expressed in $ are more appropriate for the Technical Specifications, since they are not dependent on the type of fuel used in the reactor or on the geometry of a particular core loading.
(1) The shutdown margin required by Specification 3.l(1) is necessary so that the reactor can be shut down from any operating condition and remain shut down after cooldown
. and xenon decay, even if the highest worth shim rod should stick in the fully withdrawn position, and with no credit taken for the non-scrammable regulating rod.
' (2). The reactivity of 0.60$ in Specification 3.1(2) corresponds to an asymptotic 3-sec
, period. If this period were sustained without scramming the reactor until the reactor j
l power reaches the maximum true value for the Limiting Safety System Setting (LSSS) for the High Power Scram (at which time the reactor scrams on high power), the resulting power overshoot would not exceed the safety limit for power vs. flow.
(3) The reactivity of 2.00$ in Specification 3.l(3) is less than 2.16$ which corresponds to a
. 6.9-msec period. Reactor Core DU-12/25 of the SPERT-1 series of tests had MTR plate type elements (
Reference:
Thompson and Beckerly, " Technology of Nuclear i F
g UVAR Tcch. Specs.
Reactor Safety," Volume I, page 683 (1964)). A 6.9-msec period was nondestructive.
i The simultaneous failure of more than two experiments is considered unlikely.
(4) The total reactivity of 2.50$ in Specification 3.1(4) places a reasonable upper limit on the worth of all experiments.
(5) The limit of 6.50$ on excess reactivity is to allow for xenon override and operational flexibility and to ensure that the operational reactor is reasonably similar in L
. configuration to the reactor core analyzed in the SAR. In general, the excess reactivity is limited by the shutdown margin requirement.
i l
- (rest of page intentionally left blank) l l
\\ -
UVAR Tech. Specs.
3.2.
Reactor sarerv system Applicability: This specification applies to the reactor safety system channels.
Objective: The objective is to stipulate the minimum number of reactor safety system channels that must be operable to ensure that the safety limit is not exceeded during normal operation.
Snecification: The reactor shall not be operated unless the safety system channels described in Table 3.1 Safety System Channels are operable.
Bucs The startup interlock, which requires a neutron count rate of at least 2 counts per second (CPS) before the reactor is operated, ensures that sufficient neutrons are available for proper operation of the startup channel.
The pool-water temperature scram provides protection to ensure that if the limiting safety system setting is exceeded an immediate shutdown will occur to keep the fuel temperature below the safety limit, Power level scrams are provided to ensure that the reactor power is maintained within the licensed limits and to protect against abnormally high fuel temperatures. The manual scram allows the operator to shut down the reactor if an unsafe or abnormal condition arises. The period scram is provided to ensure that the power level does not increase above that described in the SAR.
Specifications on the pool-water level are included as safety measures in the event of a serious loss of primary water Reactor operations are terminated if a major leak occurs in the primary system. The analysis in the SAR shows the consequences resulting from loss of coolant.
The bridge radiation monitor gives warning of a high radiation level in the reactor room from failure of an experiment or from a significant drop in pool-water level.
l A scram from loss of primary coolant flow, loss of power to the pump, or application of power to the pump when operating in the natural convection mode, protects the reactor from overheating, l
Air pressure to the header above ambient results in a scram to:
- 1) Ensure that the header falls with loss of primary pump power when the reactor is operating in the forced convection mode.
l
- 2) Prevent raising the header when the reactor is in the natural convection mode.
- 3) Avoid producing additional Ar-41 by activating air introduced into the header.
(rest of page intentionally left blank)
UVAR Tech. Specs.
TABLE 3.1 SAFETY SYSTEM CHANNELS Minimum Operating Mode Measuring Channel Set Point
- Function No. Operable Required Pool water level monitor 2
19'2" (min)
Scram Forced convection Bridge radiation monitor 1
30 mr/hr Scram All modes Pool water temperature 1
108 F (max)
Scram All modes loss of power Scram Forced convection Power to primary pump 1
application of Natural Scram power convection Primary coolant flow I
900 gpm (min)
Scram Forced convection Prevents Startup count rate 1
2 cps (min) withdrawal of Reactor startup any shim rod Manual button 1
Scram All modes 3 MWt (max)
Scram Forced convection Reactor power level 2
Natural 0.3 MWt (max)
Scram convection Reactor period 1
3.3 sec (min)
Scram All modes Air pressure to header 1
above ambient Scram All modes Values listed are limiting set points. For operational convenience, set points may be changed to more consenrative values.
V UVAR Tech. Specs.
3.3.
Reactor Instrumentation Annlicabihtv: This specification applies to the instrumentation that must be operable for safe operation of the reactor.
p Ohjective:' The objective is to require that sufficient information is available to the operator j
to ensure safe operation of the reactor.
Specification The reactor shall not be operated unless the measuring channels described in l
. Section 3.2 nanctar Safety Svesema and in Table 3.2 M*==nring Channela are operable.
Bassa: The neutron detectors and the core gamma monitor provide assurance that -
measurements of the reactor power level are adequately covered at both low and high power ranges.
The radiation monitors provide information to operating personnel of a decrease in pool-water level and of an impending or existing danger from radiation contamination or streaming, allowing ample time to take necessary precautions to initiate safety action.
The reactor room constant air monitor and reactor face monitor provide redundant measures
. of abnormal high radiation levels. Because the other measuring channels for determining the
(
- radiation levels are required for reactor operation, the reactor can be operated safely if these l
monitors are not functioning for short periods of time.
l (rest of page intentionally left blank) i i
i I
l 1
i i
i I i i
I
UVAR Tech. Specs.
Table 3.2 Measuring Channels Minimum No.
Operating Mode in Which Measuring Channel Operable Required Linear power 1
All modes Intermediate power (Log N) and period 1
All modes Core gamma monitor
- 1 Forced convection mode
- I Reactor room constant air monitor
- 1 All modes
- Bridge radiation monitor 1
All modes Reactor face monitor
- 1 All modes
- Pool-water level monitor 2
Forced convection mode Pool-water temperature 1
All modes Primary coolant flow 1
Forced convection mode Startup count rate 1
Reactor startup Reactor power level 2
All modes The reactor room constant air monitor, reactor face monitor, and core gamma monitor may be out of service for a period not to exceed 7 days without requiring reactor shutdown. If the reactor face monitor cannot be repaired within 7 days, it may be replaced by a locally alarming I
monitor of similar range for up to 30 days without requiring a reactor shutdown.
r-UVAR Tech. Specs.
l 3.4.
Radioactive Effluents Applicability: This specification applies to the monitoring of radioactive effluents from the Reactor Facility. Airborne and liquid effluents are discussed separately in the following sections.
I 3.4.1.
Airborne Effluents Objective: The objective is to ensure that exposure to the public resulting from the release of Ar-41 and other airborne effluents to the environment will be below the limits of 10 CFR 20 for unrestricted areas.
Specification: The activity of gases released beyond the Reactor Facility's site boundary shall not exceed 10 CFR 20 limits. When a neutron beamport vented to the atmosphere is drained of water during reactor operations and until such time as the beamport has been refilled, the effluent shall be monitored by an instrument located in the effluent vent and the effluent vent will have sufficient flow to maintain releases within 10 CFR 20 limits.
Bases: A basis for this specification is given by the analysis in the SAR. Compliance with federal regulation is another basis.
3.4.2.
Liouid Effluents Obiective: The objective is to ensure that exposure to the public resulting from the release of radioactive effluents will be below the limits of 10 CFR 20 for unrestricted areas.
Specification: The activity of liquids released beyond the Reactor Facility's site boundary shall not exceed 10 CFR 20 limits.
Basis: The basis for this specification is compliance with federal regulations.
(rest of page intentionally left blank) i i t=
o UVAR Tech. Specs.
3.5.
Confinement Applienhility: This specification applies to the capability of isolating the UVAR's reactor room, when necessary.
Obiective: The objective is to prevent exposure to the public from exceeding the limits of 10 CFR 20 for unrestricted areas, resulting from airborne activity released into the UVAR's reactor room, by providing confinement.
Specification: The reactor shall not be operated unless the following equipment is operable.
Eauipment Function Truck door closed switch Scram reactor when truck door is not fully closed Ventilation duct doors Close and seal when Bridge Radiation Monitor alarms Personnel door Close and seal when Bridge Radiation Monitor alarms Emergency exit manhole Water level is high enough to form a water water level seal at least 6 in. in depth Basis: The basis for this specification is compliance with federal regulations.
(rest of page intentionally left blank) p
~
i UVAR Tech. Specs.
3.6.
I imientinn on Funerimente Annlicahility: These specifications apply to experiments installed in the reactor and its experimental facilities.
Obiective: The object e is to prevent damage to the reactor or excessive release of 8
radioactive materials in the event of an experiment failure.
Specifications:
- 3.6.1.
Reactivity.
The reactor shall not be operated unless the following conditions exist:
(1) The reactivity worth of all experiments shall be in conformance with specifications in :
- Section 3.1.
(2) Movable' experiments must be worth less than 0.13$.
.(3) Experiments worth more than 0.13$ must be inserted or removed with the reactor shut
. down except as noted in Item (4).-
(4) Previously tried experiments with measured worth less than 0.50$ may be inserted or removed with the reactor 2.70$ or more subcritical.
(5)' If an experiment worth more than 0.50$ is inserted in the reactor, a procedure approved by the Reactor Safety Committee shall be followed.
3.6.2.
Conrainers
. (1) All materials to be irradiated in the reactor shall be either corrosion resistant or encapsulated within~ corrosion resistant containers.
(2) Irradiation containers to be used in the reactor in which a static pressure will exist or in which a pressure buildup is predicted shall be designed and tested for a pre;sure exceeding the maximum expected by a factor of 2.
3.6.3.
Danoerous Materials l
Explosive material shall not be allowed in the reactor unless specifically approved by the Reactor Safety Committee. Experiments reviewed by the Reactor Safety Committee
{
in which the material is potentially explosive, either while contained or if it leaks from the container, shall be designed to prevent damage to the reactor core or to the control rods or instrumentation, and to prevent any changes in reactivity. g
UVAR Tech. Specs.
3.6.4.
Cooling Cooling shall be provided to prevent the surface temperature of an experiment to be irradiated from exceeding the boiling point of the reactor pool water.
3.6.5.
Precautions Experimental apparatus, material, or equipment to be inserted in the reactor, shall not be positioned so as to cause shadowing of the nuclear instrumentation, interference with the control rods, or other perturbations that may interfere with the safe operation of the reactor.
3.6.6.
Cobalt Facility i
The Co-60 pins possessed under the UVAR Operating License when used and stored in the UVAR pool shall be at distances greater than 5 feet from the operating UVAR reactor. Gamma irradiation facilities utilizing the Co-60 pins shall be designed to prevent physical damage to the Co-60 pins. When the Co-60 pins are in the pool,
)
UVAR pool water samples shall be subjected to gamma spectroscopy for the presence of Co-60 on a monthly frequency, (interval not to exceed six weeks) to assure that substantial leakage of Co-60 from the pins to reactor pool water does not occur.
Bases: (TS 3.6.1 - 3.6.5) The limitations on experiments specified in TS 3.6.1 through TS 3.6.5 are based on the irradiation program authorized by Amendment No. 3 to License No. R-66 dated August 13,1%2. The reactivity of less than 0.13$ that can be inserted or removed with the reactor in operation is to accommodate experiments in the rabbits.
(Co-60 Facility) When the Co-60 pins are in the UVAR pool they shall be kept a safe distance away from the UVAR reactor when it is operated, to avoid neutron activation and possible failure of the pin cladding, which may result in leakage of Co-60 to the reactor pool water. The Co-60 pins and the gamma irradiation facilities in which they are used will not be used in conjunction with the UVAR.
The monthly reactor pool water sampling frequency, adopted to monitor possible Co-60 leakage from the pins, is the same as that used in the U.S. AEC Safety Evaluation that was performed for these pins by the Division of Reactor Licensing on August 4,1971.
This is a reasonable frequency, for the most likely damage to the pins would be caused by cladding corrosion leading to pin holes. Co-60 leakage under these circumstances would proceed very slowly, into a large pool of water. Therefore, a monthly water sampling and analysis frequency should be adequate to indicate contamination levels before they become significant. UVAR poolwater need not be sampled and analyzed for Co-60 leakage if all Co-60 pins have been removed from the pool. 1
m j
i UVAR Tech. Specs.
3.7.
Oneratinn with Fueled Ernerimente Annlienhility: This specification applies to the operation of the reactor with a fueled experiment within the reactor building.
Obiective: The objective is to ensure that the confinement leak rate and fission product inventory in fueled experiments are within limits used in the safety analysis.
Specificariana:
3.7.1. = Fueled Funerimente Generatino Power Above or Eaual to 1 W For fueled experiments in which the thermal power generated is greater than or equal to I watt (W), the reactor shall not be operated unless the following conditions are satisfied:
(1) The experiment must be in the reactor pool and under at least 15 ft of water.
(2) The thermal power (or fission rate) generated in the experiment is not greater than 100 W (3.2 x 100 fissions /sec).
(3) The calculated total energy produced by the experiment shall not exceed 600 W-years.
(4) The leak rate from the reactor room is not greater than 50% of containment of volume
- in 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> as measured within the previous 12 months.
3.7.2.
Fueled Funerimenta Generatine Power Below I W Fueled experiments in which the thermal power generated is less than 1 W (3.2 x 10'0 fissions /sec):
(1) May be located anywhere in the reactor building.
~
(2) The calculated total energy produced by the experiment shall not exceed 600 W-years.
Bases: In the event of the failure of a fueled experiment, with the subsequent release of fission products (100% noble gas,50% iodine,1% solids), the 2-hour inhalation exposures to iodine and strontium 90 isotopes at the facility exclusion distance,70 meters, are less than the limits set by 10 CFR 20, using an averaging period of 1 year.
The safety analyses for which results are used here are found in the SAR. The analysis supporting Specification 3.7.2 assumes 100% exfiltration of fission products from the reactor building in 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. The analysis supporting Specification 3.7.1 for the fueled experiments within the reactor pool assumes a fission product retention in the reactor room equivalent to 100% fission product exfiltration in 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br />. The specification provides suitable allowance for degradation between tests. The measurement of the exfiltration value is described in the SAR.
! =.
P UVAR Tech. Specs.
3.8.
Height of Water Above the Core in Natural Convection Mode of Operation Applicability: This specification applies to the height of water above the reactor core when the reactor is operating with natural convection cooling.
Obiective: The objective is to ensure that there is a continuous path for circulation of water l
when the reactor is operated in the natural convection mode.
Specification: The reactor shall not be operated in the natural convection mode unless there is at least 1 ft of water above the core.
Bases: One foot of water above the core is sufficient to provide a continuous path for natural convection cooling. For other than zero power operation, the radiation levels may require a greater depth for shielding, in which case the regulations in 10 CFR 20 will govern.
(rest of page intentionally left blank) l UVAR Tech. Specs.
3.9.
Rod Droo Times Applicability: This specification applies to the time from the initiation of a scram to the time a rod starts to drop (magnet release time) as well as to the time it takes for a rod to drop from the fully withdrawn to the fully inserted position (free-drop time).
l Obiective: The objective is to ensure that the reactor can be shut down within a specified period of time.
Specification The reactor will not be operated unless (1) the magnet release time for each of the three shim rods is less than 50 msec and (2) the free-drop time for each of the three shim rods is less than 700 msec.
Has:s: Rod drop times as specified will ensure that the safety limit will not be exceeded in a short period transient. The analysis is given in the SAR.
(rest of page intentionally left blank) l a
i l
UVAR Tech. Specs.
3.10.
Fmergency Demnval of Decay Heat This TS has been deleted because the reactor core has been permanently unloaded. The emergency decay heat removal system is designed to only cool elements located on the gridplate. As fuel will never be placed on the gridplate again, this TS is no longer needed.
(rest of page intentionally left blank) _ __
UVAR Tech. Specs.
3.11.
Primary Coolant Condition i
Applicability: Technical Specification 3.11 applies until all reactor fuel elements and Co-60 pins have been removed from the UVAR pool. Following their removal, TS 3.11 is not applicable during the permanent shutdown and decommissioning period. A substitute TS for this period is unnecessary. This specification applies to the quality of the primary coolant in contact with the fuel cladding.
Obiectives: The objectives are (1) to minimize the possibility for corrosion of the cladding on the fuel elements and (2) to minimize neutron activation of dissolved materials.
Specifications:
3.11.1. Conductivity if reactor fuel elements or cobalt-60 pins are present in the UVAR pool, the conductivity of the pool water shall be no higher than 5 x 10-6 mhos/cm.
3.11.2. Water pH l
If reactor fuel elements or cobalt-60 pins are present in the UVAR pool, the water pH of the poolwater shall be between 5.0 and 7.5.
Bases: A small rate of corrosion continuously occurs in a water-metal system. To limit this rate, and thereby extend the longevity and integrity of the fuel cladding, a water cleanup system is required. Experience with water quality control at many reactor facilities has shown that maintenance within the specified limits provides acceptable control.
By limiting the concentrations of dissolved materials in the water, the radioactivity of j
neutron activation products is limited. This is consistent with the as low as is reasonably achievable (ALARA) principle, and tends to decrease the inventory of radionuclides in the entire coolant system, which will decrease personnel exposures during maintenance and operations.
Following removal of all fuel elements and Co-60 pins from the pool, fuel cladding and Co-60 pin jacket corrosion due to improper poolwater conditions is no longer possible.
Also, activation of dissolved minerals in the poolwater cannot occur if the reactor does not operate. Consequently, primary water quality conditions can be relaxed and need not be specified in the Technical Specifications once all fuel element and cobalt pins are removed from the pool.
)
l 3.12 Poolwater-Level Monitoring i
Applicability: This specification applies to the poolwater-level float switch which monitors l
poolwater level and has alert and alarm functions.
l l
Obiective: The goal is to prevent severe loss of poolwater level while cobalt pins are kept in l
storage in the UVAR pool. Excessive loss of water level could result in diminished UVAR Tech. Specs.
' shielding and generation of a radiation fiazzard.
Specification: Until all cobalt pins have been permanently removed from the UVAR pool, a poolwater level float switch shall be operating.
1 Basis: The water-level float switch is a simple device able to sense small decreases in poolwater level and perform timely local and remote alert and alarm functions.
l l
(rest of page intentionally left blank) l l
l 1
l l
l l
I 1
1 1
UVAR Tech. Specs.
4.0.
SURVEII I ANCE REOUIREMENTS TS 4.1 through 4.3 and 4.5 through 4.7, and 4.9, have all been deleted. - Thejustification for each deletion is given below. TS 4.4 has been modified with respect to its applicability.
4.1 This TS has been deleted because surveillance requirements on shim rod operation, rod drop times, reactivity measurements and rod physical condition either are not possible, necessary or appropriate if the reactor has been permanently and completely unloaded from the core gridplate.
4.2 This TS has been deleted because a reactor safety system only is necessary for an operating or operable reactor. Safety system channel tests, checks, calibrations, and a core heat balance either are not possible, necessary or appropriate if the reactor has been permanently and completely unloaded from the core gridplate.
t 4.3 This TS has been deleted because the emergency core spray system does not need to be checked and its flow rate measured if the reactor has been permanently and completely unloaded from the core gridplate.
4.4 The wording as to the applicability of this TS has been changed to recognize that once the reactor fuel has been completely removed from the Facility, and the Co-60 pins are no longer stored in the UVAR pool, an area radiation monitoring system will no longer be i
needed because it will then be impossible to generate very high radiation levels.
4.5 This TS has been revised at NRC request to insure that operation of the radiation monitors is verified after maintenance or modifications.
4.6 This TS has been deleted because surveillance of the reactor room closure equipment operability is not necessary or appropriate if the reactor has been permanently shut down and completely unloaded from the core gridplate. Fueled experiments cannot be run, and the fission product levels in the fuel are far below the levels in an operating reactor.
4.7 This TS has been deleted because surveillance of the airborne effluent monitor of the ventilation duct from the ground floor experimental area is not necessary or appropriate with the reactor permanently and completely defuelled. No experiments producing airborne effluents in association with the reactor can be run.
4.8 The wording to this TS has been modified, taking into account that it cannot be deleted until TS 3.11 no longer applies.
4.9 This TS has been deleted because secondary system coolant surveillance is not possible or needed if the reactor is permanently shut down. The surveillance relies on the regular production of Na-24 in the primary coolant by an operating reactor. At this time, all Na-24 has decayed away. Also, with the reactor shutdown a leak in the heat exchanger would result in secondary coolant flow into the primary coolant, and not the other way around as is the case when the reactor is being operated with the primary coolant pump on.
4.10
. This TS has been added by NRC request to assure safe storage of cobalt in the UVAR pool. c
l UVAR Tech. Specs.
4.4.
Area Radiation Monitorine Eauinment
(
Applicability: TS 4.4 applies to the bridge radiation monitor referenced in Table 3.1. This TS will cease to apply once all UVAR fuel elements have been removed from the Reactor Facility and all Co-60 pins have been taken from the UVAR pool for shielded storage elsewhere.
Obiectives: The objectives are to ensure that the radiation monitoring equipment is operating and to verify appropriate alarm settings.
Specification:
4.4.1 Daily Ooerability Verification The operation of the radiation monitoring equipment and the position of their associated alarm set points shall be verified daily during periods when the reactor is in operation.
4.4.2.
Semiannual Calibration The calibration of the bridge radiation monw referenced in Table 3.1 shall be performed semiannually until all fuel elemen.s nave been removed from the Reactor Facility and all Co-60 pins have been taken from the UVAR pool for dry shielded storage or appropriate disposal.
Bases Surveillance of the monitoring equipment will provide assurance that sufficient warning of a potential radiation hazard is available.
l l
4.5.
Maintenance Aoplicablity: This specification applies to the surveillance requirements following maintenance of the area radiation monitoring system.
Obiective: The goal is to ensure that the area radiation monitoring system is operable following maintenance, repair or modification and prior to first use.
Specification: Following maintenance, repair or modification of the area radiation monitoring system, it shall be verified that the system is operable before it is returned to service.
Bases: It is necessary to ensure that any work on or change made to the system is carried out properly so that the system will operate as intended and that the system or component has been properly reinstalleii or reconnected. Operability must be verified prior to the first use 9
of the system following maintenance, repair or modification.
l i
(rest of page intentionally left blank)
{
1.
UVAR Tech. Specs.
4.8.
Primary Coolant Conditinns Applicability: This specification applies to the surveillance of primary water quality whenever either fuel elements and/or Co-60 pins are in storage in the UVAR pool.
Obiective: The objective is to ensure that water quality does not deteriorate over extended periods of time should the reactor not be operated and either fuel elements and/or Co-60 pins be in storage in the UVAR pool.
L Specification: If the conductivity and pH of the primary coolant water is required to be maintained as per TS 3.11, then they shall be measured at least once every 2 weeks and verified to be as follows:
Conductivity:
s 5 x 104 mhos/cm pH:
between 5.0 and 7.5 Bases: Section 3.11 of these specifications ensures that the water quality is adequate during reactor operation. This section ensures that water quality is adequate whenever either fuel elements and/or Co-60 pins are in the UVAR pool and the reactor is not operated.
4.10.
Surveillance of Reactor Poolwater Level Applicability: Technical Specification 4.10 applies until all Cobalt-60 pins have been removed from the UVAR pool. This TS specifies the surveillance frequency of poolwater
- level monitoring instrumentation.
Obiective: The goal is to detect significant poolwater leak rates well before loss of poolwater results in radiation hazard due to cobalt stored in the pool.
Specification: The poolwater level float switch shall be checked for operabdity, alarm and alert functions on a weekly basis until all cobalt pins have been r: moved permanently from the UVAR pool.
Bases: Poolwater is lost from the open UVAR pool by evaporation and small leaks. Makeup water is added about twice weekly, at which time the actual water level is checked and recorded.
(rest of page intentionally left blank)
UVAR Tech. Specs.
5.0.
DESIGN FEATURES 5.1.
Panctor Fuel Snecificarians -
-Annlicahility: These specifications apply to UVAR low enriched uranium (LEU) fuel.
Obiective: The objective is to describe LEU fuel approved by the U.S. NRC for use in the UVAR.
Snecifications:
5.1.1.
Fuel Matenal UVAR LEU fuel is of a type described for use at U.S. research reactors by the U.S.
Nuclear Regulatory Commission (NUREG-1313 " Safety Evaluation Report Related to the Evaluation of LEU Silicide Aluminum-Dispersed Fuel for Use in Non-Power
' Reactors"). The fuel meat is U Si dispersed in an aluminum matrix and enriched to 3 2 less than 20% U-235.
5.1.2.
Element Desenption (1) Plate-type elements of the MTR type are used. The fuel " meat" is clad with aluminum alloy to form flat fuel plates. The active length of the fuel region in the fuel plates is approximately 24 inches and the width is approximately 2.5 inches. The LEU fuel plates are joined ' t their long-side edges to two side plates. The entire fuel plate a
assembly is joined at the bottom to a cylindrical nose piece that fits into the UVAR core gridplate. The overall fuel elemem dimensions are approximately 3 inches by 3 inches by 36 inches. Each fuel plate contains 12.5 grams of U-235.
(2) " Standard". LEU fuel elements are composed of 22 parallel flat fuel plates each, and contain 275 grams of U-235.
i
- (3) " Control rod" LEU elements are similar to the standard elements, with the exception that they have half as many fuel plates (the 11 center plates being removed to form a channel which is bounded by 0.125 inch thick aluminum plates). Control-rod elements accommodate the control rods in the central channel. Their U-235 content is 137.5 grams.
)
)
and 11 unfuelled (dummy) plates. The U-235 content in these elements is 137.5 grams.
(5) "Special" LEU fuel elements have 22 fuel plates, of which 20 are removable. The
- maximum U-235 content in these elements is 275 grams and the minimum is 25 grams.
- 3. IL
E UVAR Tech. Specs.
5.1.3.
Core Configurations A variety of UVAR core configurations may be used to accommodate experiments, but the loadings shall always be such that the minimum shutdown margin and excess reactivity specified in the UVAR Technical Specifications are not exceeded.
Bases. The NRC has described LEU silicide-fuel suitable for use in U.S. research reactors in NUREG-1313 " Safety Evaluation Report Related to the Evaluation of LEU Silicide Aluminum-Dispersed Fuel for Use in Non-Power Reactors," [$36.00, from NTIS, Springfield Va. (703-487-4650)]. Also, Bretscher and Snelgrove from the Argonne National Laboratory documented LEU fuel test results in ANURERTR/TM-14, "The Whole-Core LEU U Si -Al Fuel Demonstration in the 30-MW Oak Ridge 3 2 Research Reactor." The LEU-SAR for the UVAR contains the safety analysis performed for the 22 flat-plate University of Virginia fuel elements. The LEU elements were designed by EG&G, Idaho, and are manufactured by the Babcock and Wilcox Company of Lynchburg, Virginia.
(rest of page intentionally left blank)
)
i UVAR Tech. Specs.
5.2.
Reactor Buildine TS 5.2 has been deleted, for the specifications on confinement, ventilation and reactor room free volume have been required to restrict leakage of radionuclides produced during reactor operation at power. The UVAR is no longer operated.
(rest of page intentionally left blank) t
)
- t-
UVAR Tech. Specs.
5.3.
Fuel Use and Storage Applicability: With the exception of Technical Specification 5.3.2, TS 5.3 applies until all reactor fuel elements have been removed from the UVAR Facility. Following their removal, TS 5.3 is not applicable during the permanent shutdown and duommissioning period. The specifications below apply to University of Virginia Reactor fuel used and/or stored at the University of Virginia Reactor Facility.
Obiective: The objective is to describe reactor fuel which may be used, possessed and/or stored at the University of Virginia Reactor Facility as well as measures that avoid nuclear criticality or fuel-related accidents.
Specifications:
5.3.1 LEU Possession Limil A maximum of 4 kilograms of contained uranium-235 at less than 20% enrichment (which is defined as low enriched uranium, LEU) may be possessed at the Reactor Facility.
5.3.2.
Plutonium Possession Limit I
All plutonium contained in start-up sources, irradiation targets, flux foils and fission chambers, which totals less than 131 grams, is possessed at the Reactor Facility under the University's By-Product License and not the Reactor License.
5.3.3.
Storage Reactivity Limitation All reactor fuel elements, including fueled experiments and fuel devices not in the reactor, shall be stored in a geometric array where calculated km is no greater than 0.9 for all conditions of moderation and reflection using light water, except in cases where an approved fuel shipping container is used, in which case the fuel loading F iitations specified in the certificate of compliance for the container shall apply.
5.3.4.
Storage Cooline Reauirement Irradiated fuel elements and fueled devices shall be stored in an array that will permit sufficient natural convection cooling by water or air so that the fuel element or fueled device surface temperature will not exceed the boiling point of water.
Bases: Section 5.4 of the American National Standard ANSI /ANS-15.1-1990, "The Development of Technical Specifications for Research Reactors," was used as the overall basis for the above specifications. The limit given in specification 5.3.1 is based on an estimated reasonable need for reactor fuel for use in the core and a spare fuel requirement determined by DOE's expected spare fuel manufacturing schedule. The specification in 5.3.2 is based on the unavoidable production of small amounts of plutonium in reactor fuel, sources, irradiation targets, flux foils and fission chambers, as a consequence of normal reactor operation. Precise amounts of plutonium produced, decayed or burned during reactor operation is hard to quantify, and this is not necessary for the small amounts of plutonium produced and contained in these aforementioned devices pose no undue reactor or radiation safety risks.
UVAR Tech. Specs.
6.0.
- ADMINISTRATIVE CONTROLS 6.1.
Organization Applicability-The specifications listed below in TS 6.1.1 through TS 6.1.4. apply to the organizational structure of the University of Virginia as it relates to the activities conducted at the Reactor Facility during the permanent shutdown and decommissioning period.
Obiective: The objective is to describe the chain of command having responsibility for the safe maintenance, defueling, decontamination and decommissioning of the Reactor Facility.
At the various administration levels, the functions, assignments, responsibilities and associated professional background, training and requalification requirements are listed, as applicable.
Specifications:
6.1.1.
Structure The Reactor Facility shall be an integral part of the University of Virginia. The organizational structure of U.Va.. relating to the Reactor Facility is shown in Figure j
6.1. The Vice President for Research and Public Service (Level 1) shall have overall responsibility for management of the Facility.
The Reactor Decommissioning Committee Chair shall be responsible for advising the Reactor Director (Level 2) on all matters pertaining to the decommissioning and i
- decontamination of the University of Virginia Reactor Facility. The decommissioning j
committee members may include reactor staff from Level 3, and employees from the j
Office of Environmental Health and Safety.
i 6.1.2.
Resoonsibility During the UVAR permanent shutdown and decommissioning period, the Reactor Facility Director (Level 2) shall be responsible for overall facility operation and the direction of decommissioning activities at the Reactor Facility.
During periods when the Reactor Facility Director is absent, the Director's responsibilities are automatically delegated to the Reactor Supervisor (Level 3).
The Reactor Facility Director shall have at least a bachelor's degree in science or engineering and a minimum of 5 years of experience in the nuclear field. A graduate degree may fulfill 4 years of experience on a one-for-one time basis.
The Reactor Supervisor shall be responsible for the day-to-day activities at the UVAR l
and ensuring that these are conducted in a safe manner and within the limits prescribed by the facility license. During periods when the Reactor Supervisor is absent, his responsibilities are delegated to a person at (Level 4).
l l L
UVAR Tech. Specs.
The Reactor Supervisor shall have the equivalent of a bachelor's degree in science or engineering and at least 2 years of experience in Reactor Operations at this facility, or an equivalent facility, or at least 6 years of experience in Reactor Operations.
Equivalent education or experience may be substituted for a degree. Within nine months after being assigned to the position, the Reactor Supervisor shall obtain and maintain a NRC Senior Reactor Operator license if reactor fuel elements are still at the Facility. A NRC Senior Reactor Operator license, or a Reactor Operator license, is not required for level 3 and 4 personnel once all reactor fuel elements have been shipped offsite.
6.1.3.
Staffing A licensed Senior Reactor Operator shall supervise any movement of reactor fuel. One l
or more health physicists, organizationally independent of the Reactor Staff as shown in Figure 6.1, shall be responsible for rachlogical safety at the Reactor Facility.
6.1.4.
Selection and Train ne of Personnel i
The selection, training and requalification of Reactcr Facility personnel shall follow the American National Standard for Selection and Training of Personnel for Research Reactors, ANSI /ANS-15.4-1988, Sections 4-6, to the extent applicable to the decommissioning status of the facility. The selected criteria for the personnel will be contained in the NRC-approved Operator Requalification Program, as amended.
Bases. Sections 6.1,6.1.1,6.1.2,6.1.3 and 6.1.4 of the American National Standard i
ANSI /ANS 15.1-1990 "The Development of Technical Specifications for Research l
Reactors," describe a generic and generally acceptable organizational structure for U.S.
research reactors.
l They provide the bases for TS 6.1 above. Some of the ANSI standard recommendations l
apply to operable or operating reactor facilities, and are not necessarily valid for staff hired to perform decommissioning activities.
(rest of page intentionally left blank) l l
l l
l l
1 i
i l l
l
p i
UVAR Tech. Specs.
'.2 Eadiation Safety. Reactor Safety and Reactor Decommissioning Committees 6
6.2.A. Radiation Safety Committee Applicability: The specifications 6.2.A.1 and 6.2A.2 apply to the expert group who will provide oversight over the Reactor Safety and Reactor Decommissioning Committees.
Obiective: To describe the makeup, responsibilities, and authority of the Radiation Safety
)
Committee as regards reactor permanent shutdown and decommissioning.
I Specifications:
6.2.A.I.
Composition and Oualification There shall be a Radiation Safety Committee (RaSC) to ensure that the Reactor Facility is shutdown and decommissioned in a safe manner within the terms of its reactor and other licenses, teactor Technical Specifications and NRC approved plans. The RaSC shall advise the Vice President and Provost and the Director of the Reactor Facility on safety and other concerns involving the decommissioning of the Reactor Facility.
The RaSC shall include its Chairman, the Radiation Safety Officer, the Director of the Reactor Facility, representatives of the hospital administration, Nuclear Medicine, and Radiological Physics or Radiation Oncology. Additional members may be drawn from such areas as Environmental Health and Safety, Radiology, Pathology, Biology, Nursing, Nuclear Engineering, Microbiology, Physics, Obstectrics and Gynecology. Membership of the RaSC will change as appointments are made by the Office of the President of the University.
However, the Radiation Safety Officer and the Reactor Director shall have standing appointments to the RaSC. Collectively, the RaSC members shall represent a broad spectrum of expertise in the radiological sciences. The membership of the Committee shall be such so as to maintain a high degree of technical proficiency in areas relating to radiation safety. The RaSC Chairman is the coordinator for all university licenses involving the use of radioactive materials and radiation producing equipment.
The Radiation Safety Committee is charged with ensuring that licensed material is used safely and in compliance with NRC regulations and institutional licenses. The RaSC reviews changes to the Broad Scope and other licenses. The RaSC also identifies program problems 1
and recommends solutions and remedial actions. Some of its functions are carried out through the use of subcommittees, such as the Reactor Safety Committee and the Reactor i
Decommissioning Committee. The RaSC will carry out most of its functions relating to the Reactor Facility through these two subcommittees.
6.2.A.2.
RaSC Charter and Rules (1) To establish a quorum, the ex-officio members and any 5 other Committee members j
must be present.
I l
' (2) The Committee shall meet as often as necessary to conduct its business by not less than once in each calendar quarter.
UVAR Tech. Specs.
(3) The Committee shall have a written charter defining such matters as the authority of the Committee, the subjects within its purview, and other administrative provisions.
(4) Radiation Safety Committee meeting minutes shall be distributed to the committee membership within three months following a meeting. These m?nutes shall be reviewed for approval at the next scheduled committee meeting.
6.2.B.
Reactor Safety Committee Applicability: The specifications 6.2.B.1 through 6.2B.3 apply to the expert group who will provide specific reviews and audits of Reactor Facility operations while reactor fuel elements are on-site.
Objective: To describe the makeup, responsibilities, and authority of the Reactor Safety Committee.
Specifications:
6.2.B. l.
Comnosition and Oualification There shall be a Reactor Safety Committee (Re SC) to review and audit reactor operations and ensure that the Reactor Facility is operated in a safe manner within the terms of the reactor i
license. However, reactor safety concerns will end once all reactor fuel elements have been j
permanently shipped from the Reactor Facility. At that time the need for a Re SC shall l
cease, and any remaining radiation safety issues shall be referred to and be addressed by the University's Radiation Safety Committee. The Technical Specification requirement for a Reactor Safety Committee shall cease following the shipment of all reactor fuel elements off-site.
The Reactor Safety Committee shall be part (a subcommittee) of the Radiation Safety Committee (RaSC) and report to its Chairman, who is the coordinator for all licenses involving the use of radioactive materials and radiation producing equipment at the University of Virginia. The Reactor Safety Committee shall be composed of at least four members, and shall include the Radiation Safety Officer of the University and the Director of the Reactor Facility. The Reactor Director shall be the sole reactor staff representative on the Committee. Collectively, the committee members shall represent a broad spectrum of expertise in the research-reactor field. The membership of the Committee shall be such so as to maintain a degree of technical proficiency in areas relating to reactor safety. The members may be drawn from within or outside the operating organization.
The ReSC shall advise the Vice President for Research and Public Service and the Director i
of the Reactor Facility on reactor safety concerns with the operation of the facility. ReSC l
reviews and audits are designed to uncover deficiencies that affect reactor safety.
6.2.B.2.
Charter and Rules (1) A quorum of the Committee shall consist of not less than the majority of the full committee. The Chair can designate another member from the Committee to preside in l
l l L-
UVAR Tech. Specs.
his absence.
(2) The Committee shall meet at least semiannually and shall be on call by the Chair.
Minutes of all meetings shall be disseminated as designated by the Chair.
(3) The Committee shall have a written charter defming such matters as the authority of the Committee, the subjects within its purview, and other administrative provisions as are required for effective functioning of the Committee.
(4) Reactor Safety Committee meeting minutes shall be distributed to the committee membership within three months following a meeting. These minutes shall be reviewed for approval at the next scheduled committee meeting.
6.2.B.3. Review and Audit Functions As a minimum the responsibilities of the Reactor Safety Committee include:
(1) Review and approval of untried experiments and tests that are significantly different from those previously used or tested in the reactor, as determined by the Facility Director.
(2) Review and approval of changes to the reactor core, reactor systems or design features that may affect the safety of the reactor.
(3) Review and approve all proposed amendments to the reactor license, Technical Specifications, and changes to the standard operating procedures (Note: SOPS are discussed in Section 6.3 of these specifications).
(4) Review reportable occurrences, to include violations of Technical Specifications, License or of Standard Operating Procedures that have safety significance, as well as the occurrences listed in ANSI /ANS-15.1 Item 6.6.2. Also, to review the actions taken to identify and correct the cause of these occurrences.
(5) Review significant operating abnormalities or deviations from normal performance of facility equipment that affect reactor safety.
(6) Audit annually (through a selective yet comprehensive examination of records, logs and persomiel]:
i a) Facility operations for conformance to TS and License b) Results of actions taken to correct verified deficiencies that may occur in reactor equipment, systems, structures or method of operations that affect reactor safety.
.. and audit biennially:
c) Operator retraining and requalification program for the reactor operations staff d) Reactor Facility Emergency Plan and Implementing Procedures l J
o UVAR Tech. Specs.
(7) Review and approval of changes to experiments, reactor systems and procedures as per 10 CFR 50.59.
Bases: American National Standard ANSI /ANS-15.1-1990, "The Development of Tecimical Specifications for Research Reactors," describes in Section 6.2 acceptable composition and qualification criteria for reactor safety committees and their review and audit functions.
Section 6.3 of the standard describes the organizational relationship of the group responsible for radiation safety to the reactor operations group. These sections of the standard are used as bases for the specifications listed above.
(rest of page intentionally left blank) i 4
l l
i t.
UVAR Tech. Specs.
6.2.C. Reactor Decommincionino Committee Apphcability: The specifications 6.2.C.1 through 6.2C.3 apply to the expert group who will have responsibility and oversight for decommissioning planning and execution activities at the Reactor Facility.
Obiective: To describe the makeup, responsibilities and authority of the Reactor Decommissioning Committee.
Specifications:
6.2.C. l.
Comoosition and Oualification There shall be a Reactor Decommissioning Committee (RDC) to plan the safe, legal and timely decommissioning of the Reactor Facility. Collectively, the decommissioning committee members shall represent a broad spectrum of expertise in the research-reactor and health-physics fields, with experience in reactor management, radiological safety, research reactor decommissioning and university administration. Committee members may be drawn from within or outside the University of Virginia, including subcontracted companies. The Committee shall be composed of at least four members, and shall include the Radiation Safety Officer of the University and the Director of the Reactor Facility.
The Reactor Decommissioning Committee shall be part (subcommittee) of the Radiation Safety Committee, which reports to the Vice President and Provost. The Decommissioning Committee shall advise the Reactor Director (Level 2) on all matters impacting the decommissioning of the Reactor Facility.-
6.2.C.2.
Charter and Rules (1) A quorum of the Decommissioning Committee shall consist of not less than the majority l
of the full committee. The RDC Chair can designate another member from the Committee to preside in his absence.
(2) The Reactor Decommissioning Committee shall meet at least quarterly and shall be on call by the Chair. Meeting minutes shall be disseminated as per the RDC Charter.
(3) The Reactor Decommissioning Committee shall have a written charter defining such matters as the authority of the Committee, the subjects within its purview, and other administrative provisions as are required for effective functioning of the Committee.
(4) The Reactor Director shall cast a single vote in the name of the operations staff at Reactor Decommissioning Committee meetings. The operations staff encompasses the reactor staff, decommissioning subcontractors and anyone directly supporting decommissioning and working under the direction of the Reactor Director.
l (5) Reactor Decommissioning Committee meeting minutes shall be distributed to the committee membership within three months following a meeting. These minutes shall be reviewed for approval at the next scheduled committee meeting. L1
F I
UVAR Tech. Specs.
6.2.C.3.
Decammiccionine Camminee Functions As a minimum, the responsibilities of the Reactor Decommissioning Committee following the termination of the Reactor Safety Committee shall include:
(1) Review and approval for c!aanges to the Reactor Facility and to the UVAR SOPS as applicable and described in 10 CFR 50.59.
(2) Review and approval of proposed changes to reactor licenses, Technical Specifications, NRC-approved plans (such as the Emergency and Security Plans), as well as the UVAR Standard Operating Procedures (SOPS), with the exception of changes to the organizational structure. [The responsibility and authority for the organizational structure for the Reactor Facility resides with the Vice President and Provost.]
(3) Review unusual and reportable occurrences, to include those violations of Technical Specifications, License, or of Standard Operating Procedures that have safety significance, as well as the occurrences listed in ANSI /ANS-15.1 Item 6.6.2. Also, to review the actions taken by reactor management to identify and correct the cause of these occurrences.
i (4) Annually audit [through a selective, yet comprehensive, examination of records, logs and personnel] facility operations for conformance to licenses, Technical Specifications, NRC regulations and inspections, as well as UVAR SOPS; and to recommend remedial action to correct identified deficiencies.
(5) Biennially audit the Operator Retraining and Requalification Program of the reactor staff, as well as the Reactor Facility Emergency Plan and Implementing Procedures.
(rest of page intentionally left blank) 46 -
UVAR Tech. Spccs.
i
,.J
UVAR Tech. Specs.
1 I
l J
l l
1 i
I r
l
UVAR Tech. Specs.
6.3.
Stadard Operatino Prombres Applicability: The specification below concerns the procedural controls used to operate the University of Virginia Reactor (UVAR) and conduct experiments.
Obiective: The objective is the safe operation of the reactor in compliance with license conditions, federal regulations.
Specifications:
l l
6.3.1.
Items Covered by SOPS
- Written procedures, reviewed and approved by the Reactor Safety Committee shall be in effect and followed for the items listed below. These procedures shall be adequate to ensure the safe decommissioning of the reactor, but should not preclude the use of independent judgment and action should the situation require such.
(1) Startup, operation and shutdown of the reactor.
(2) Installation or removal of fuel elements, control rods, experiments, and experimental facilities.
(3) Actions to be taken to correct specific and foreseen potential malfunctions of systems or components, including responses to alarms, suspected primary coolant system leaks, abnormal reactivity changes.
(4) Emergency conditions involving potential or actual release of radioactivity, including provisions for evacuation, re-entry, recovery, and medical support.
(5) Preventative and corrective maintenance operations that could have an effect on reactor safety.
(6) Periodic surveillance.
(7) Radiation control.
6.3.2.
Channes to SOPS Changes that do not change the original intent of the procedures may be made with the approval of the Facility Director. All such minor changes shall be documented and subsequently reviewed by the Reactor Safety Committee (or by the Reactor Decommissioning Committee after the ReSC ceases to exist).
Basis: Section 6.4 of American National Standard ANSI /ANS 15.1-1990, "The Development of Technical Specifications for Research Reactors," suggests acceptable procedural controls to applied to operating U.S. research reactors. _
s UVAR Tech. Specs.
l l
6.4.
Review and Approval of Experiments Applicability: Specifications 6.4.1 through 6.4.6 listed below apply to classes of experiments run in the UVAR core, in the UVAR pool, or which use UVAR-generated l
neutron and/or gamma-radiation beams. However, a partial listing of examples of experimental work covered under experiment classes for which broad approval may have been obtained and, therefore, for which individualized experimental procedures would nel be required follows below:
(a) Samples to be irradiated in approved irradiation facilities, such as the neutron activation facilities, where the samples meet the criteria in TS 3.6 and TS 6.4.
(b) Samples to be irradiated in the neutron radiography facility beamport which are known not to be hazardous to reactor safety.
Objective: The objective is the safe operation of the reactor and experiments, in accordance with license conditions and federal regulations. Experiments run in conjunction with the reactor should not adversely affect reactor and radiation safety. Notwithstanding the regard for safety, the requirement for review and approval of experiments shall not limit the flexibility of experimenters performing work covered under general written procedures, or for which unanalyzed safety issues do not exist, as determined by the Reactor Director.
Speci6 cations:
l 6.4.1.
Experimental Procedures and Methods (1) Classes of experiments involving the UVAR, the UVAR pool or UVAR radiation beam facilities shall be carried out with established and approved written experimental procedures. The Reactor Safety Committee shall review all new classes of experiments prior to their initiation and approve written experimental procedures governing their operation.
(2) Written experimental methods that implement Reactor Safety Committee approved experimental procedures may be developed by the staff and/or experimenters, as needed. Such experimental methods shall be approved by a Reactor Supervisor or the Reactor Director prior to use.
(3) The Reactor Director or the Reactor Safety Committee shall decide whether an experimental procedure is required. Usually, an experimental procedure will not be required if the work in question is already covered under an existing approved general experimental procedure or by a Standard Operating Procedure.
6.4.2.
Reactivity limits l
As applicable, reactivity limits for experiments given in experimental procedures shall be based on analyses of maximum reactivity insertions that can be handled by the reactor or its control and safety systems without exceeding safety limits. Reactivity limits have been established in TS 3.6 limitations on Exneriments far maximum absolute reactivity worth of f
individual experiments and the sum of the absolute values of the worth of all experiments.
1 UVAR Tech. Specs.
]
6.4.3.
Materials As applicable, special requirements shall be established in the experimental procedures for significant amounts of special materials such as fissionable materials, explosives or metastable materials capable of significant energy release, or materials that are corrosive to reactor components or highly reactive with coolants. Requirements listed in experimental procedures may range from detailed analyses to double encapsulation and prototype testing.
6.4.4.
Failure and Malfunctions (1) Credible failures of any experiments shall not result in the release or exposures in excess of the annual limits established in Title 10, Code of Federal Regulations, Part 20.
(2) Experiments shall be designed such that they will not contribute to the failure of other experiments, core components, or principal physical barriers to uncontrolled release of radioactivity. Similarly, no reactor transient shall cause an experiment to fail in such a way as to mntribute to an accident.
6.4.5.
Exnerimental Facility Snecific LCO Limiting Conditions of Operation limits unique to an experiment shall be specified, as necessary, in the written experimental procedures. Specific surveillance activities which may be required for experiments will also be addressed in the experimental procedures.
6.4.6.
Deviatinns from Exnerimental ProceAnres (1) Changes to previously approved experiments and experimental procedures, determined by the Reactor Director to be substantive, shall be made only after review and approval by the Reactor Safety Committee.
(2) Minor changes to experimental procedures may be made with the approval of the Reactor Director, who will determine that no new reactor safety concerns exist, and with the approval of the Reactor Health Physicist, who will assure that radiological safety requirements can be met.
i Bases: National Standard ANSI /ANS-15.1-1990, "The Development of Tecimical Specifications for Research Reactors," suggests acceptable provisions governing reactor-
- based experiments in sections 3.6 and 6.4.~ These sections served as bases for the above specification. In addition, examples are presented of activities involving the reactor which typically do not require individualized written procedures, because they are covered under a general procedure for an approved class of experiments, or covered by SOPS. It is unreasonable to require procedures with undue specificity when this would limit reasonable experimental flexibility and no unanalyzed safety issues exist. The Reactor Director has the resources and authority to determine when experimental procedures are required.
r UVAR Tech. Specs.
6.5 Plant Operatine Records Applicability: The specifications below apply to UVAR operating records.
Objective: The objective is to maintain and keep on file reactor operating records for future reference, and for demonstration of compliance with license conditions and federal regulations.
Specifications:
6.5.1.
Records To Be Retained for at least Five Years in addition to the requirements of applics.ble regulations, records of the items listed below shall be kept in a manner convenient for review:
(1) Normal reactor facility operation (for example, reactor logbooks, reactor checklists and irradiation request forms).
(2) Principal reactor systems maintenance records.
(3) Reportable occurrences.
(4) Equipment and component surveillance activity required by Technical Specifications.
(5) Reactor Facility radiation and contamination surveys.
(6) Experiments performed with the UVAR.
(7) Fuel inventories, transfers of radioactive material to and from the R-66 license.
(8) Approved changes to operating procedures.
(9) Records of meetings and audit reports of the Reactor Safety Committee.
(10) Records of meetings and audit reports of the Reactor Decommissioning Committee.
6.5.2.
Records To Be Retained for One Certification Cycle Records of retraining and requalification of licensed operators shall be maintained at all times the individual is employed or until licensing is renewed.
(rest of page intentionally left blank) l L
1 UVAR Tech. Specs.
6.5.3.
Racords To Be Ratnined for the Life of the Facility In addition to the requirements of applicable regulations, records (or logs) of the items listed below shall be kept in a manner convenient for review and shall be retained as indicated:
(1) Gaseous and liquid radioactive effluents released from the Reactor Facility.
(2) Off-site (radiological) environmental monitoring surveys.
(3) Radiation exposures for all personnel monitored at the Reactor Facility.
(4) Updated, corrected and as-built drawings of the Reactor Facility.
1 (5) Changes to reactor systems, components, or equipment that may affect reactor safety Basis: American National Standard ANSI /ANS-15.1-1990, "The Development of Technical Specifications for Research Reactors," provides record-keeping guidance in Section 6.8. This is the basis for the above specifications.
(rest of page intentionally left blank) i UVAR Tech. Spces.
6.6,.
Required Actions
- Anoliemhility:.The specifications below apply to instances where radiologically unsafe situations have been, or were likely to have been, generated.
Obiective: The objective is to report unsafe' conditions, study their causes and
. consequences, determine their effect on the health and safety of personnel and the public, and take corrective action to prevent recurrence.
Soecifications:
6.6.1.
Action To Be Taken in the Event of a Renortable Occurrence A reportable occurrence is any of the following conditions:
(1) An observed inadequacy in the implementation of either administrative or procedural controls, such that the inadequacy could have caused the existence or development of an unsafe condition at the Reactor Facility.
(2) Abnormal and significant degradation in reactor fuel,' and/or cladding, coolant boundary, or containment boundary (excluding minor leaks) where applicable that could result in exceeding prescribed radiation-exposure limits of personnel and/or environment.
(3) Major damage to the Co-60 pins resulting in Co-60 concentrations in reactor pool water
. in excess of 1 x 104 micro-curies /ml.
In the event of a reportable occurrence, the following action shall be taken:
(a) Ongoing activities shall cease until the occurrence has been resolved.
- (b) The Director of the Reactor Facility or his designee shall be notified as soon as possible and corrective action taken as foreseen in the procedures.
(c) A written report of the occurrence shall be made which shall include an analysis of the cause of the occurrence, the corrective action taken, and recommendations for measures to preclude or reduce the probability of reoccurrence. This report shall be submitted to the Director and the Reactor Safety Committee and/or the Radiation Safety Officer for review.
(d) A report shall be submitted to the Nuclear Regulatory Commission in accordance with Section 6.7 of these specifications.-
Bases: National Standard ANSI /ANS-15.1 1990, "The Development of Technical Specifications for Research Reactors," describes in sections 6.6 and 6.7 acceptable specifications for required actions related to safety limits violations, actions to be taken upon their discovery, and reporting requirements. These form the bases for the above specifications.
- 5'4 -
1 UVAR Tech. Specs.
6.7.
Reoorting Reauirements Apphcability: The specifications 6.7.1 and 6.7.2 listed below apply to routine and special reports made by the University of Virginia Reactor Facility to the U.S. Nuclear Regulatory l
Commission.
Obiective: The objective is to provide the licensing agency (NRC) with relevant information concerning normal and abnormal reactor operations which are necessary for the fulfillment i
I of its mission to protect the public health and safety. A secondary objective is to comply with reporting requirements as given in the federal regulations.
Specifications: In addition to federal regulatory requirements (for example, follow 10 CFR 20, 30.50, 40.60, and 70.50, as applicable), reports should be made to the U.S. Nuclear l
Regulatory Commission as follows:
6.7.1.
Recorring of Incidants (1) Immediate notification should be made by telephone, to the U.S. Nuclear Regulatory Commission Headquarters Operations Center of:
(a) Personnel total effective dose equivalent of 25 rem or more.
(b) The release of radioactive material, inside or outside of a restricted area, that results, or could result, over a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period, in personnel intake of 5 times the annual limit on intake specified in 10 CFR 20.
(2) A special report should be made by telephone as soon as possible, but no later than the next working day, to the U.S. Nuclear Regulatory Commission Headquarters Operations Center of:
(a) Personnel exposures or releases of radioactive material greater than the limits in 10 CFR 20.
i (b) Reportable occurrences as defined in Section 6.6.2 of ANSI /ANS-15.1.
(c) Violation of a safety limit or technical specification.
(3) A special written report should be sent by mail within 14 days to the U.S. Nuclear Regulatory Commission, Document Control Desk, Washington, D.C. 20555 (a) Accidental off-site release of radioactivity above 10 CFR 20 limits, whether or not the release resulted in property damage, personal injury, or exposure.
(b) Reportable occurrence as defined in Section 6.6.2 of ANSI /ANS-15.1.
(c) Violation of a safety limit or technical specification.
l l
r
]
UVAR Tech. Specs.
. (4) A special written report should be sent by mail within 30 days to the U.S. Nuclear I,
' Regulatory Commission, Document Control Desk, Washington, D.C. 20555, of:
(a) - Accidental off-site release of radioactivity above 10CFR20 limits, whether or not the release resulted in property damage, personnel injury, or exposure.
(b) Reportable occurrence as defined in Section 6.6.2 of these specifications.
(c) Changes in personnel serving as Vice President For Research and Public Service, the Radiation Safety Committee Chair, Reactor Decommissioning Committee -
' Chairman, Reactor Safety Committee Chair, Reactor Facility Director, or Reactor Supervisor.
J (5) A written report should be sent within nine months after initial criticality of the reactor or within 90 days of completion of the startup test programs, whichever is earlier, to the U.S. Nuclear Regulatory Commission, Document Control Desk, Washington, D.C.
20555, upon receipt of a new facility license, an amendment to the license authorizing an increase in power level or the installation of a new core with fuel elements of a l.
design different design than previously used. The report will include the measured i
values of the operating conditions or characteristics of the reactor under the new conditions, including:
(a) Total control rod reactivity worth, i
(b) Reactivity worth of the single control rod of highest reactivity worth.
(c) Minimum shutdown margin both at ambient and operating temperatures.
6.7.2, Routine Annnni Renorts A routine annual report will be made by March 31 of each year on decommissioning and related activities completed during the previous calendar year. The report should be sent to the U.S. Nuclear Regulatory Commission, Document Control Desk, Washington, D.C. 20555, providing the following information:
(1) Reactor Facility utilization, (2) Description of university staff assigned to decommissioning: numbers, background and responsibilities, (3) TS compliance and reportable events, (4) Results of NRC inspections and licensing actions, (5) Summary report on RDC meetings and audit findings, (6) Health Physics Program (7) Annual waste content and volume shipped, l~
(8) Summary of the nature and amount of radioactive solid, liquid and airborne effluents released or discharged to the environs beyond the effective control of the licensee, as measured or calculated at or prior to the point of such release or discharge, f-(9) Results of environmental surveys and sampling outside the Reactor Facility, 1 l
UVAR Tech. Specs.
(10)
Reactor Facility personnel and visitor radiation exposure summary report, including the dates and times of significant exposures (greater than 500 mrem for adults and 50 mrem for persons under 18 years of age),
(11)
Summary of radiation and contamination surveys performed within the Reactor
- Facility, (12)
Status of decommissioning funding and expenditures, (13)
Description of contractor companies operating on-site, (14)
Summary of contracted tasks and timelines, (15)
Significant Changes to the Reactor Facility, Reactor SOPS and of all changes made per 10 CFR 50.59, (16)
Summary of large equipment transfers, (17)
New and modified SOPS having radiation safety significance, (18)
Status of emergency preparedness, (19)
Figures on industrial accidents or incidents.
(rest of page intentionally left blank) i l L