m 3 ;m ORANDUM FOR: Thomas M. Novak, Assistant Director for Licensing, Division of Licensing FROM:
L. S. Rubenstein, Assistent Director for Core and Plant Systems, Division of Systems Integrat'on
SUBJECT:
RESPONSE TO DIABLO CANYON ALLEGATION NO. 1545, AVAILIARY SYSTEMS BRANCH Enclosed as requested by DL is the Auxiliary Systems Branch's response to Diablo Canyon allegation No. 1545. We have concluded based on our previcus reviews in the area of subcompartment environments resulting from postulated high energy pipe breaks outside containment, that the concerns expressed in the allegation are not significant to safety and the licensee.need take cdi further action in this regard.
In addition, we are also enclosing a previous response dated July 17, 1984 to what appears to be the same allegation which was prepared by the Containment Systems Branch.
O ('..Lu.. k L. S. Rubenstein, Asristant Director +
for Core a:td Plant Systems Division of Systems Integratior
Enclosure:
As Stated CC W/ enclosure:
i R. Bernero J. P. Knight R. Houston
- 0. Parr W. Butler G. Knighton H. Schierling J. Wermiel M. Ley J. Ridgely
+
s l
Contact:
J. Wermiel i
X29462
~
hfo 7 Z OO9e) g)
/
4
o DIABLO CANYON, UNITS 1 AND 2 RESPONSE TO ALLEGATION N0. 1545 AUXILIARY SYSTEMS BRANCH Task: Allegation or Concern No. 1545 Characterization Errors in the FLUD computer model used by the licensee to establish environ-ments in subcompartments following postulated high energy pipe breaks outside containment may result in incorrect pressure / temperature profiles for purposes of environmental qualification of safety-related equipment.
Implied Significance to Plant Design, Construction, or Operation Incorrectly defined pressure / temperature profiles for various subcompartments would mean that new analyses would be required using a different computer model.
If the newly determined environments were significantly different from those previously defined, safety-related equipment would require requalification.
j i
Assessment of Safety Significance
^
/
t The staff previousily reviewed and evaluated the licensees program (including use of the FLUD computer code) for establishing equipment qualification envelops as part of its review of the Diablo Canyon IDVP (refer to Diablo Can'or SSER, NUREG-0675, Supplement No. 18). This evaluation included an y
independent calculation of the pressure / temperature profile for selected jubcompartmentsoutsidecontainmentutilizingtheCOBREEcomputercode. The siaff believes the COBREE model is the current state-of-the-art for analyses for this type and has been benchmarked against actual test results to confirm it's accuracy. The results of this comparison showed good correlation between
'the FLUD and COBREE calculated room pressures and temperatures.
.t 3
t
' ll gop e
s h
d e
l
.l
2 Staff Position Based on the above, the staff concludes that the licensee has utilized an acceptable methodology for determining subcompartment environments resulting from postulated pipe breaks outside containment. Therefore, the concerns expressed in this allegation do not impact our conclusion regarding the safety of the plant in this regard.
Action Required None
-