MONTHYEARML20206T2581999-01-0303 January 1999 Rev 0 to Annual Radioactive Effluent Rept for 980105-990103 Supplemental Info ML20207H1161998-12-31031 December 1998 Annual Repts of Occupational Radiation Exposure Primary Coolant Iodine Spikes & Safety Relief Valve Challenges for Jan-Dec 1998 ML20206T2531998-12-31031 December 1998 Off-Site Radiation Dose Assessment for NSP for Jan-Dec 1998 ML20207D7661998-12-31031 December 1998 Annual ISFSI Effluent Rept Jan-Dec 1998. with ML20206H6981998-12-31031 December 1998 1998 Annual Radiological Environ Monitoring Rept for PINGP, Unit 1 & 2 ML20206T2741998-12-31031 December 1998 Effluent & Waste Disposal Annual Rept Solid Waste & Irradiated Fuel Shipments for Jan-Dec 1998 ML20217Q8321998-01-0404 January 1998 Annual Radioactive Efluent Report,961230-980104, Suppl Info ML20247G1621997-12-31031 December 1997 1997 Annual Radiological Environ Monitoring Rept ML20203K0551997-12-31031 December 1997 Annual Repts of Occupational Radiation Exposure,Primary Coolant Iodine Spikes & Safety Relief Valve Challenges for Jan-Dec 1997 ML20217Q8251997-12-31031 December 1997 Off-Site Radiation Dose Assessment for NSP,Jan-Dec 1997 ML20217Q8391997-12-31031 December 1997 Effluent & Waste Disposal Annual Rept Solid Waste & Irradiated Fuel Shipments for Jan-Dec 1997 ML20202G2181997-12-31031 December 1997 Annual ISFSI Effluent Rept Jan-Dec 1997 ML20138P5321996-12-31031 December 1996 Annual Repts of Occupational Radiation Exposure & Safety Relief Valve Challenges for Period from 960101-1231 ML20248K1951996-12-31031 December 1996 Rev 1 to App D, Special Ground & Well Water Samples, of 1996 Annual Radiation Environ Monitoring Program Rept ML20141A4101996-12-31031 December 1996 Rev 0 to Annual Radioactive Effluent Rept 960101-1231 Suppl Info ML20210K1401996-12-31031 December 1996 Rev 1 to Annual Radioactive Effluent & Waste Disposal Rept for Jan-Dec 1996 ML20248K1911995-12-31031 December 1995 Rev 1 to App D, Special Ground & Well Water Samples, of 1995 Annual Radiation Environ Monitoring Program Rept ML20117F9061995-12-31031 December 1995 Annual Radioactive Effluent & Waste Disposal Rept for Jan- Dec 1995 ML20117F9331994-12-31031 December 1994 Rev 1 to 1994 Effluent Semiannual Rept ML20080Q6161994-12-31031 December 1994 Annual Rept of Occupational Radiation Exposure & Safety Relief Valve Challenges - Jan-Dec 1994 ML20248K1731994-12-31031 December 1994 Rev 1 to App D, Special Ground & Well Water Samples, of 1994 Annual Radiation Environ Monitoring Program Rept ML20072T1451994-07-0303 July 1994 Rev 0 to Effluent Semiannual Rept 940103-0703 ML20072T1581994-07-0101 July 1994 Rev 5 to Effluent & Waste Disposal Semiannual Rept Solid Waste & Irradiated Fuel Shipments ML20029D2141993-12-31031 December 1993 Annual Rept to NRC Radiation Environ Monitoring Program Jan-Dec 1993. ML20064B6941993-12-31031 December 1993 Effluent & Waste Disposal Semiannual Rept for Jul-Dec 1993 ML20064C3781993-12-31031 December 1993 Annual Rept of Occupational Radiation Exposure & Safety Relief Valve Challenges for Jan - Dec 1993 ML20056G6981993-06-30030 June 1993 Effluent & Waste Disposal Semiannual Rept Jan-June 1993 ML20056G7161993-01-0303 January 1993 Effluent Semiannual Rept 920706-930103, Supplemental Info ML20056G7141992-12-31031 December 1992 Revised Semiannual Rept Third & Fourth Quarters 1992 ML20058Q2561992-12-31031 December 1992 Revised 1992 Annual Radiological Environ Monitoring Rept ML20141M5121992-07-0505 July 1992 Effluent Semiannual Rept,920106-0705,Supplemental Info ML20056G7131992-06-30030 June 1992 Revised Semiannual Rept First & Second Quarters 1992 ML20141M5351992-01-0505 January 1992 Effluent Semiannual Rept,910701-920105,Supplemental Info ML20056G7121991-12-31031 December 1991 Revised Quarterly Release Rept Third & Fourth Quarters 1991 ML20101S8601991-12-31031 December 1991 Rev to Summary Page 2 of 1991 Annual Radiological Environ Monitoring Rept ML20090B6401991-12-31031 December 1991 Annual Rept of Occupational Radiation Exposure & Safety & Relief Valve Failures & Challenges,1991 ML20090C1911991-12-31031 December 1991 Effluent & Waste Disposal Semiannual Rept for Jul-Dec 1991 ML20056G7101991-06-30030 June 1991 Revised Semiannual Rept for First & Second Quarters 1991 ML20082M2851991-06-30030 June 1991 Effluent & Waste Disposal Semiannual Rept for Prairie Island Nuclear Generating Plant for Units 1 & 2 ML20073F1731990-12-31031 December 1990 Annual Rept to NRC of Radiation Environ Monitoring Program 1990 ML20056G7071990-12-31031 December 1990 Revised Quarterly Release Rept Third & Fourth Quarters 1990 ML20066H7211990-12-31031 December 1990 Annual Rept for Occupational Exposure,Safety/Relief Valve Failures & Challenges,Primary Coolant Spike & Personnel Whole Body Exposure for 1990 ML20029A8011990-12-31031 December 1990 Supplemental Effluent & Waste Disposal Semiannual Rept for Jul-Dec 1990. ML20056G7051990-06-30030 June 1990 Revised Quarterly Release Rept First & Second Quarters 1990 ML20028G8421990-06-30030 June 1990 Effluent & Waste Disposal Semiannual Rept for Jan-June 1990. ML20056G7041989-12-31031 December 1989 Revised Quarterly Release Rept for Third & Fourth Quarters 1989 ML20079N3751989-12-31031 December 1989 Environ Monitoring & Ecological Studies Program for Prairie Island Nuclear Generating Plant,1989 Annual Rept ML20042E8111989-12-31031 December 1989 Radiation Environ Monitoring Program Rept 1989. ML20028G8431989-12-31031 December 1989 Supplemental Info to Effluent Semiannual Rept for Jul-Dec 1989 ML20011F5811989-12-31031 December 1989 Annual Rept of Occupational Radiation Exposure and Safety Relief Valve Failures and Challenges. W/900226 Ltr 1999-01-03
[Table view] Category:TEXT-ENVIRONMENTAL REPORTS
MONTHYEARML20206T2581999-01-0303 January 1999 Rev 0 to Annual Radioactive Effluent Rept for 980105-990103 Supplemental Info ML20206T2531998-12-31031 December 1998 Off-Site Radiation Dose Assessment for NSP for Jan-Dec 1998 ML20206T2741998-12-31031 December 1998 Effluent & Waste Disposal Annual Rept Solid Waste & Irradiated Fuel Shipments for Jan-Dec 1998 ML20207D7661998-12-31031 December 1998 Annual ISFSI Effluent Rept Jan-Dec 1998. with ML20206H6981998-12-31031 December 1998 1998 Annual Radiological Environ Monitoring Rept for PINGP, Unit 1 & 2 ML20207H1161998-12-31031 December 1998 Annual Repts of Occupational Radiation Exposure Primary Coolant Iodine Spikes & Safety Relief Valve Challenges for Jan-Dec 1998 ML20217Q8321998-01-0404 January 1998 Annual Radioactive Efluent Report,961230-980104, Suppl Info ML20202G2181997-12-31031 December 1997 Annual ISFSI Effluent Rept Jan-Dec 1997 ML20217Q8391997-12-31031 December 1997 Effluent & Waste Disposal Annual Rept Solid Waste & Irradiated Fuel Shipments for Jan-Dec 1997 ML20203K0551997-12-31031 December 1997 Annual Repts of Occupational Radiation Exposure,Primary Coolant Iodine Spikes & Safety Relief Valve Challenges for Jan-Dec 1997 ML20247G1621997-12-31031 December 1997 1997 Annual Radiological Environ Monitoring Rept ML20217Q8251997-12-31031 December 1997 Off-Site Radiation Dose Assessment for NSP,Jan-Dec 1997 ML20140B5501997-06-0404 June 1997 Environ Assessment & Finding of No Significant Impact Re Util Proposed Amends to Licenses DPR-42 & DPR-60,allowing Credit for Soluble Boron in Spent Fuel Pool in Maintaining Acceptable Margin of Subcriticality ML20248K1951996-12-31031 December 1996 Rev 1 to App D, Special Ground & Well Water Samples, of 1996 Annual Radiation Environ Monitoring Program Rept ML20210K1401996-12-31031 December 1996 Rev 1 to Annual Radioactive Effluent & Waste Disposal Rept for Jan-Dec 1996 ML20138P5321996-12-31031 December 1996 Annual Repts of Occupational Radiation Exposure & Safety Relief Valve Challenges for Period from 960101-1231 ML20141A4101996-12-31031 December 1996 Rev 0 to Annual Radioactive Effluent Rept 960101-1231 Suppl Info ML20117F9061995-12-31031 December 1995 Annual Radioactive Effluent & Waste Disposal Rept for Jan- Dec 1995 ML20248K1911995-12-31031 December 1995 Rev 1 to App D, Special Ground & Well Water Samples, of 1995 Annual Radiation Environ Monitoring Program Rept ML20248K1731994-12-31031 December 1994 Rev 1 to App D, Special Ground & Well Water Samples, of 1994 Annual Radiation Environ Monitoring Program Rept ML20080Q6161994-12-31031 December 1994 Annual Rept of Occupational Radiation Exposure & Safety Relief Valve Challenges - Jan-Dec 1994 ML20117F9331994-12-31031 December 1994 Rev 1 to 1994 Effluent Semiannual Rept ML20072T1451994-07-0303 July 1994 Rev 0 to Effluent Semiannual Rept 940103-0703 ML20072T1581994-07-0101 July 1994 Rev 5 to Effluent & Waste Disposal Semiannual Rept Solid Waste & Irradiated Fuel Shipments ML20064C3781993-12-31031 December 1993 Annual Rept of Occupational Radiation Exposure & Safety Relief Valve Challenges for Jan - Dec 1993 ML20064B6941993-12-31031 December 1993 Effluent & Waste Disposal Semiannual Rept for Jul-Dec 1993 ML20029D2141993-12-31031 December 1993 Annual Rept to NRC Radiation Environ Monitoring Program Jan-Dec 1993. ML20056G6981993-06-30030 June 1993 Effluent & Waste Disposal Semiannual Rept Jan-June 1993 ML20056G7161993-01-0303 January 1993 Effluent Semiannual Rept 920706-930103, Supplemental Info ML20056G7141992-12-31031 December 1992 Revised Semiannual Rept Third & Fourth Quarters 1992 ML20058Q2561992-12-31031 December 1992 Revised 1992 Annual Radiological Environ Monitoring Rept ML20141M5121992-07-0505 July 1992 Effluent Semiannual Rept,920106-0705,Supplemental Info ML20056G7131992-06-30030 June 1992 Revised Semiannual Rept First & Second Quarters 1992 ML20141M5351992-01-0505 January 1992 Effluent Semiannual Rept,910701-920105,Supplemental Info ML20056G7121991-12-31031 December 1991 Revised Quarterly Release Rept Third & Fourth Quarters 1991 ML20090C1911991-12-31031 December 1991 Effluent & Waste Disposal Semiannual Rept for Jul-Dec 1991 ML20101S8601991-12-31031 December 1991 Rev to Summary Page 2 of 1991 Annual Radiological Environ Monitoring Rept ML20090B6401991-12-31031 December 1991 Annual Rept of Occupational Radiation Exposure & Safety & Relief Valve Failures & Challenges,1991 ML20056G7101991-06-30030 June 1991 Revised Semiannual Rept for First & Second Quarters 1991 ML20082M2851991-06-30030 June 1991 Effluent & Waste Disposal Semiannual Rept for Prairie Island Nuclear Generating Plant for Units 1 & 2 ML20066H7211990-12-31031 December 1990 Annual Rept for Occupational Exposure,Safety/Relief Valve Failures & Challenges,Primary Coolant Spike & Personnel Whole Body Exposure for 1990 ML20073F1731990-12-31031 December 1990 Annual Rept to NRC of Radiation Environ Monitoring Program 1990 ML20056G7071990-12-31031 December 1990 Revised Quarterly Release Rept Third & Fourth Quarters 1990 ML20029A8011990-12-31031 December 1990 Supplemental Effluent & Waste Disposal Semiannual Rept for Jul-Dec 1990. ML20056G7051990-06-30030 June 1990 Revised Quarterly Release Rept First & Second Quarters 1990 ML20028G8421990-06-30030 June 1990 Effluent & Waste Disposal Semiannual Rept for Jan-June 1990. ML20056G7041989-12-31031 December 1989 Revised Quarterly Release Rept for Third & Fourth Quarters 1989 ML20042E8111989-12-31031 December 1989 Radiation Environ Monitoring Program Rept 1989. ML20028G8431989-12-31031 December 1989 Supplemental Info to Effluent Semiannual Rept for Jul-Dec 1989 ML20011F5811989-12-31031 December 1989 Annual Rept of Occupational Radiation Exposure and Safety Relief Valve Failures and Challenges. W/900226 Ltr 1999-01-03
[Table view] |
Text
.
Attachment 1 PRAIRIE ISLAND NUCLEAR GENERATING PLANT NORTHERN STATES POWER COMPANY OFF-SITE RADIATION DOSE ASSESSMENT FOR NORTHERN STATES POWER COMPANY January through December 1998 9905240103 990517 PDR ADOCK 05000282 R PDR '
NORTHERN STATES POWER COMPANY PRAIRIE ISLAND NUCLEAR GENERATING PIANT OFF-SITE RADIATION DOSE ASSESSMENT FOR January through December 1998 An Assessment of the radiation dose due to releases from Prairie Island Nuclear Generating Plant during 1998 was performed in accordance with the Technical Specifications. Computed doses were well below the 40 CFR Part 190 Standards and 10 CFR Part 50 Appendix I Guidelines.
Off-site dose calculation formulas and meteorological data from the Off-site Dose Calculation Manual were used in making this assessment. Source terms were obtained from the Annual Radioactive Effluent and Waste Disposal Report prepared for NRC review for the year of 1998.
Off-site Dores from Gaseous Release Computed doses due to gaseous releases are reported in Table 1. Critical receptor location and pathways for organ doses are reported in Table 2.
Doses are a small percentage of Appendix I Guidelines.
Off-site Doses from Liquid Release Computed doses due to liquid releases are reported in Table 1. Critical receptor information is reported in Table 2. Doses, both whole body and, organ, are a small percentage of Appendix I Guidelines.
Doses to Individuals Due to Activities Inside the Site Boundary occasionally sportsmen enter the Prairie Island site for recreational activities. These individuals are not expected to spend more than a few hours per year within the site boundary. Commercial and recreational river traffic exists through this area.
For purposes of estimating the dose due to recreational and river water transportation activities within the site boundary, it is assumed that the limiting dose within the site boundary would be received by an individual who spends a total of seven days per year on the river just off shore from the plant buildings (ESE at 0.2 miles). The gamma dose from noble gas releases and the whole body and organ doses from the inhalation pathway due to Iodine 131, Iodine-133, tritium and long lived particulates were calculated for this location and occupancy time. These doses were reported in Table 1.
Doses to Individuals Due to Effluent Releases from the ISFSI No additional fuel casks were loaded or placed in the storage facility during the 1998 calendar year. The total number of casks in the ISFSI remained at 7. There has been no release of radioactive effluents from the ISFSI.
Radiation Effluent Monitoring Sampling Deviations There were no sampling deviations during the reporting period.
5 1
Table 1 I l
OFF-SITE RADIATION DOSE ASSESSMENT - PRAIRIE ISLAND j PERIOD: JANUARY through DECEMBER 1998 i
10 CFR Part 50 Appendix I Guidelines for a 2-unit site per year Gaseous Releases Maximum Site Boundry Gamma Air Dose (mrad) 1.80E-05 20 Maximum Site Boundry Beta Air Dose (mrad) 1.80E-03 40 Maximum Off-site Dose to any organ (mrem)* 5.30E-02 30 Offshore Location Gamma Dose (mrad) 9.25E-07 Total Body (mrem)* 2.04E-03 Organ (mrad)* 2.05E-03 30 Liquid Releases ,
Maximum Off-site Dose Total Body (mrem) 3.66E-03 6 Maximum Off-site Dose Organ - LIVER (mrem) 4.79E-03 20 Limiting Organ Dose Organ - TOTAL BODY (mrem) 3.66E-03 6
1 Table 2 l 1
OFF-SITE RADIATION DOSE ASSESSMENT'- PRAIRIE ISLAND l SUPPLEMENTAL INFORMATION l PERIOD: JANUARY through DECEMBER 1998 Gaseous Releases Maximum Site Boundary l Dose Location I (from Building Vents)
Sector WNW Distance (miles) 0.4 Offshore Location Within Site Boundary Sector ESE Distance (miles) 0.2 ,
Pathway Inhalation l Maximum Off-site Sector SSE Distance (mil'es)' 0.6 Pathways '
Plume, Ground, -
Inhalation, Vegetables Age Group Child j Liquid Releases l Maximum Off-site Dose i Location Downstream I
Fish Pathway
!