oc**************************************************************************

UNIT 1 OPERATING DATA REPORT cc**************************************************************************

Docket No. 50-317 April 7, 1987 Prepared by C. Behnke Telephone: (301)260-4871 OPERATING STATUS

~~~~~~~~~~~~~~~~

1. UNIT NAME Calvert Cliffs Unit 1
2. REPORTING PERIOD OCTOBER 1986 (Rev 2) 3.

LICENSED THERMAL POWER (MWT) 2700

4. NAMEPLATE RATING (GROSS MWe) 918
5. DESIGN ELECTRICAL RATING (NET MWe) 845
6. MAXIMUM DEPENDABLE CAP'Y (GROSS MWe) 860
7. MAXIMUM DEPENDABLE CAP'Y (NET MWe) 825
8. CHANGE IN CAPACITY RATINGS none
9. POWER LEVEL TO WHICH RESTRICTED n/a
10. REASONS FOR RESTRICTIONS n/a Cumulative This month Year-to-Date to Date
11. HOURS IN REPORTING PERIOD 745 7,296 100,669
12. NUMBER OF HOURS REACTOR WAS CRITICAL 559.4 6,906.2 79,771.7
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 3,019.4
14. HOURS GENERATOR ON LINE 543.0 6,856.4 78,215.9
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 1,439,508 18,206,202 195,530,395
17. GROSS ELECTRICAL ENERGY GEN'TED(MWH) 480,377 6,087,181 64,689,993
18. NET ELECTRICAL ENERGY GENERATED (MWH) 458,359 5,830,803 61,747,098
19. UNIT SERVICE FACTOR 72.9 94.0 77.7
20. UNIT AVAILABILITY FACTOR 72.9 94.0 77.7
21. UNIT CAPACITY FACTOR (USING MDC NET) 74.6 96.9 74.7
22. UNIT CAPACITY FACTOR (USING DER NET) 72.8 94.6 72.6
23. UNIT FORCED OUTAGE RATE 5.6 3.8 8.6
24. SHUTDOWNS SCHEDULED OVER THE NEXT SIX MONTHS (TYPE, DATE AND DURATION):

None

25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START-UP:

January 4, 1987 8704220127 870407 PDR ADOCK 05000317 R