l FORM NI.1 OWNEEN A REPORT FOR ggsERVIO 18sPECT10NS

! As required by the Provisions of the ASME Code Rules Jersey Central Power & Light Company

1. Owner Madison Avenue & Punchbowl Road, Morristown, N.J. 07960 (Name and Address of Owner)

Oyster Creek Nuclear Generating Station

2. Plant U . S. Route 9, 2 miles south of Forked River, N.J. 08731 e and Add" #'

Oyster Creek Nuclear Cencrating

3. Plant Unic J1ation 4. Owner Certificate of Authorization (if required)_ Jo ne

$. Commerci31 Serdce D / 2 M 0' ations1 Board Number fo' U" gx vessei 14895

7. Comgo"*nts e pa%C8inspectea3 of 47 throusw 47 Of ganufacturet ComPo"'" ganufacturer or Instn\\ state of Natio"'I Appurtenance og instslief Serial N"- p,ognce No-N N

N N

N N

\

\

N .

x

\

\

N N

N Noter Supplemental sheets in form of lists, sketches, or drawings may be used provided (!) size is 84 in. x ! I in.,

(2) Information in items I through 6 on this dars report is induded on each sheer, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

l

\

ThiS IG* gg) r W be cuaW the Order pept., ASME 346 E. 47th St** N'* *k N.Y.

\

O

FORM NIS-1 (back)

8. Examination Dates 0 3- 11-85 to 12- 2 8- Rfi9. Inspection Interval from 19 7 9 to 1989
10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval. Generally the inservice inspection required for this interval is approximately 59% completed

!!. Abstract of Conditions Noted The results of the examinations have determined the components are satisfactory for continued service.

12. Abstract of Corrective Measures Recommended and Taken IGSCC examinations on Reactor Recirculation System and Isolation Condenser System resulted in repair weld overlays for three welds.

We certify that the statements made in this report are correct and the examinations and corrective mea-sures taken conform to the rules of the ASME Code,Section XI. #

Jersey Central Power u , /

Date /i 7 19 Signed & Light Company gy _ yn _ 2 / pJ Owner Certificate of Authorization No. (if applicable) Expiration Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the Natignalr inspectors and/or the State or Province of New Jersey and empioye tf'y o i!E 'dnd Pressure Vessel er1&T co. of flartford. Cn have inspected the components described in this owners' Data Report during the period 0 3 - 1 L- 8 5 to 12-2R-R6 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Data Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.

Date 3 - 13 i 9 E__

Commissions N B- 5 4 7 8 I ctor's Sign ure National floard, State. Province and No.

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ = _ _ _ _ _ _ _

l 11

.NIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 3 0F 47.

JERSEY CENTRAL P0HER AND LIGHT COMPANY

1. OWNER: MADISON AVENUE AT PUNCHB0llL ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK NUCLEAR GENERATING STATION
2. PLAf4T ON U.S. RT.9. 2 HILES SOUTH OF FORKED RIVER,N.J. 08731
3. VIIIT: OYSTER CREEK t4UCLEAR GENERATING STATION
4. 0;ttlER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. C0tutERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD nut 1BER FOR UllIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMmMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM N SYSTEtt SECT.XI EXAM COMP 0t:ENT COMPONE14T MATERIAL COMPONENT COMPONENT INSPECTION M-M BOUNTRY CATEGORY HETHOD ID DESCRIPTI0tl SPECIFICATION DIAMETER THICKNESS DATA SHEET M MMMMMMMMMMMMMMMMMMMkhMMMMMMMMMMMMMMMMMMMMMMMMMM'MMMMMMMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM m

REACTOR VESSEL B-A VT-2 2-564A LONGITUDINAL SHELL A302 GR.B CS 228.00 7.875 86-306-17 HELD IN CORE REGION 3-A VT-2 2-564B LONGITUDINAL SHELL A302 GR.B.CS 228.00 7.875 86-306-17 HLLD IN CORE REGION

^

B-A VT-2 2-564C LONGITUDINAL SHELL A302 GR.B CS 228.00 7.875' 86-306-17 HELD IN CORE REGION' B-A VT-2 2-564D LONGITUDINAL SHELL A302 GR.B CS 228.00 7.875 86-306-17 HELD IN CORE REGION

?

B-A VT-2 2-564E LONGITUDINAL SHELL A302 GR.B CS 228.00 7.875 86-306-17 HELD IN CORE REGION l

l B-A VT-2 2-564F LONGITUDINAL SHELL A302 GR.B CS- 228.00 7.875 86-306-17 HELD IN CORE REGION 3-A VT-2 3-564 CIRCUMFERENTIAL 'A302 GR.B CS 228.00 7.875 86-306-17 SHELL llELD IN CORE REGION 3-A VT-2 3-572 REACTOR VESSEL A302 GR.B CS N/A 5.188 86-306-01 CIRCUHFENtNTIAL l

HELD IN CORE t -.

j REACTOR VESSEL B-B VT-2 1-562 REACTOR VESSEL 'A302 GR.B CS N/A 5.188 86-306-G2 LOWER HEAD

-CIRCUMFERENTIAL l  :-

. . .- -- . --- -. . . . . . . .- _ -. a

1 1

11 HIS-I O!!!1ERS DATA REPORT FOR ItJSERVICE It4SPECTI0t4S PAGE 4 0F 47 JERSEY CEllTRAL POWER At1D LIGHT COMPAt4Y

1. CHf4ER: MADIS0t3 AVEt1UE AT PUNCHB0HL ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK tlUCLEAR GENERATIt!G STATI0tl
2. PL AtlT : Oft U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,H.J. 08731
3. Uf4I T : OYSTER CREEK NUCLEAR GEtlERATIllG STATI0t1 1 4. CHIIER CERTIFICATE OF AUTHORIZATI0ft (IF REQUIRED) fici4E l 5. COM;1ERICAL SERVICE DATE 12/23/69
6. NATI0tlAL BOARD tiUttbER FOR UtilT RX VESSEL 14895 M MM M M M M M M M M M M M E M M M h M M M M h M'M M M m M M m M M M h M m M M M M M M M k M M M M h M M M M M M M M h M M M MM M M M M M M M M M M M M M M M M M M M MM MM M M M M M M M M MM M M M M M M M M MMM M M M M M M M M M M M M M M M M M M M M M M SYSTEM SECT.XI EXA!! COMP 0tiEt4T COMf'0:lEtlT MATERIAL COMP 0tlEt4T COMP 0flEllT It4SPECTI0tt M M BOU!iTRY CATEGORY f1ETHOD ID DESCRIPTI0t1 SPECIFICATI0tl DIAMETER THICKi1ESS DATA SHEET M MMhaMMMhMAMMhhMMMMMAMMMMMMMMMhmuMhMkMmAMManMhMAMMMMMmMMMMMMMMMMMMMMMMMMMMMMMMkMMMMMMMMM*w=MM%%%%mmamanRMMMMMammmmmMZXM##NMMhMMMMMM l REACTOR VESSEL B-B VT-2 1-563 REACTOR VESSEL A302 GR.B CS N/A 5.188 86-306-01 l CIRCU!1FERE!1TI AL l HELD 174 CORE B-B VT-2 1-572 REACTOR VESSEL A302 GR.B CS ti/A 5.188 86-306-01 CIRCUNFEREllTIAL 11 ELD Iti CORE B-B VT-2 2-562 REACTOR VESSEL A302 GR.B CS ti/A 5.188 86-306-02 LOHER HEAD CIRCUMFEREf1TIAL B-B UT 2-563B REACTOR VESSEL L0t1G A302 GR.B CS tJ/A 7.875 001678 SEAM HELD B-B UT 2-563C REACTOR VESSEL L0tiG A302 GR.B CS N/A 7.875 002829 SEArt 11 ELD B-B UT 2-574 RfACTOR VESSEL A302 GR.B CS ti/A 5.188 002623 CLOSURE ttEAD 2% OF CIECUMFERLf4TIAL 81 ELD 3-B VT-2 3-562A REACTOR VESSEL A302 GR.B CS ti/A 5.188 86-306-02 Loller HEAD MERIDIOriAL l4 ELD B-B VT-2 3-5628 REACTOR VESSEL A302 GR.B CS N/A 5.188 86-306-02 LOMER HEAD

-- MERIDIO!!AL llELD B-B VT-2 3-562C REACTOR VESSEL A302 GR.B CS N/A 5.188 86-306-02 LOUER HEAD l  !!ERIDIO!!AL HELD B-B VT-2 3-562D REACTOR VESSEL A302 GR.B CS II/A 5.188 86-306-02 LOHER HEAD

MERIDI0t1AL !! ELD

f4IS-1 Out4ERS DATA REPORT FOR IllSERVICE IriSPECTI0 tis PAGE 5 0F 47 -

JERSEY CEt4 TRAL Poller AtID LIGHT C0t: pat 4Y

1. CH:1ER: IIADISSil AVEl10E AT PutlCHL0tlL ROAD,MORRIST08tti,N.J. 07960 ,.

OYSTER CREEK tlUCLEAR GEt4ERATIt4G STATIott

2. PL AtJ T : 013 U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,ti.J. 08731
3. UtiIT : OYSTER CRLEK fiUCLEAR GEtJERATIt!G STATI0it
4. Ou;1ER CERTIFICAiE OF t.UTHQ.NIZATI0t4 (If REQUIRED) N0 tie
5. CGliitERICAL SERVICE DATE IU23/69
6. 14ATI0tlAL BOARD t4Uf!BER FOR.JitetT RT VESSEL 14895 M M M M M m M M M M M M M M M M M M u M M M m M M M M h M M M M E M MU M M M M u m M M o n hanMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M M M M M M M h M M M MU M M k I M SYSTEM SECT.XI EXAM COMPCtlEllT C0ttP0f1EllT MATERIAL C0tiP0tlEN T ,, COMPONENT INSPECTI0t1 m W M BOUT 41 RY CATEGORY METHOD ID DESCRIPTIO!I SPECIFICATI0tl DI At1ET ER / THICKf4ESS DATA SHEET MMk M M M MMMM M M hk M M h M Mk k M M M M M E MM hM R M M a h A Ma a Ma h a h M k M M h M M M MMM MM M h MM M k MM MM MM MMMMM M MM M MM k k M M M Mk(W h)t M M M M Ku mM M Mp IOf(MILMM MMM M M MMM MhM MMhMMMM M M

/ ^

~

/? ~ G- 2 ' , . ._

i REACTOR VESSEL /

l ,.

B-B VT-2 3-562E REACTOR VESSEL ^

A302 GR.B CS 7 N/A 5.188 86-306-02 L LOWER HEAD MERIDIGt4AL !! ELD

?

- 'j N /,;

B-B VT-2 3-562F REACTOR VESSEL A302 GR.B CS N/A 5.188 86-306-02' e, '

LOHER HEAD MERIDIO!4AL HELD -

f/ -. .

B-B UT '

3-5745 REACTOR. VESSEL A302 GR.B CS ti/A 5.188 002623 CLOSURE HEAD -

MERIDI0tlAL HELD 10% -

% ' /x f B-B UT '- 5-574D REACTOR VESSEL A302 GR.B CS ta/A 5.18& . ' - t002623

~ CLOSURE HEAD \

- - - ~

MERIDIO!!AL llELD 10%  ? 7

, [ -

B-B UT 3-574F-REACTOR VESSEL CLOSURE HEAD . -

ATJz QR.B CS

~,.

- H.rA_. ,' ' . 5 185' +

002625 A -

,11ERI DI0t4AL llELD 10%

~

L,

_s-

,- 4 B-B VT-2 4-562A EEACTOR VESSEL A302 UR.B CS II/A ~ 5.188 86-306-02 '

-- LCHER HEAD s tiERIDI0t AL llELD f ., - /'

, ~#. u < -

B-B .WT-2 4-56kB_ C REACTOR VESSEL '

A302 GR.B.CS N/A  %"

5.188 86-306-02 LCHER HEAD .- ' # '

MERIDI0tlAL llELD r' B-B VT-2 4-562C' REACTOR VESSEL A302 GR M S N/A 5.188 86-306-02 L0hCR HEAD j t1ERIsjullAL HELD e-e r  %

B-B _VT-2 4-562D REACTOR VESSEL A302 GR.B CS 'g . N/ A ., 5.188 d *,-306-02 LO:!ER HEr.1

.c ,'

s~'

t1ERIDIO!!AL HE t_D

",y

~ w

/' -

. B-B , NT-t . 562E ' REACTOR VESSEL ,

L0tttR HEAD '

v.

. Mj2 GR g5 CS II/A 5.188 86-3A6-02 f1ERIDIO!aAL llELD ,. j , ,' 3 7-y / *w,

'~ ~,.

a

n. .., N

.r- -: . 3

- ~ -

.pp r . ,- s

'  ?' a e r

,~  :^ '

~., ,

-, ~.

f4IS-1 OHilERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 6 0F 47 JERSEY CEllTRAL PONER AtlD LIGHT COMPA!4Y

1. OMilER: !!ADIS0!I AVEllUE AT PUtlCHB0HL ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK liUCLEAR GEllERATIttG STATI0tl
2. FLAllT* ON U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER N.J. 08731
3. Ut!IT s OYSTER CREEK tlUCLEAR GEllERATIllG STATION
4. OtitlER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. ColiMERICAL SERVICE DATE 12/23/69
6. 14ATI0t4AL BOARD t!Ut1BER FOR Ut1IT RX VESSEL 14895 UMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXAM CGMPO!!Et4T COMP 011EllT 11ATERI AL COMPONEl4T COMP 0tiENT - INSPECTION M d BOUNTRY CATECORY ttETHOD ID DESCRIPTI0tl SPECIFICATION DI At1ETER . THICKt4ESS DATA SHEET M l DMMMakMMMMMhhMhakMhknMMhMkMMMMMMMMMMMhM dM MMMh Ad dhhMMMMkh dMM AMMMMMMMMkMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMM MMMMMMMMMMMMMMMMMMMMMMMMMMM REACTOR VESSEL B-B VT-2 4-562F REACTOR VESSEL A302 GR.B CS li/A 5.188 86-306-02 L0l!ER HEAD MERID10llAL 11 ELD B-B VT-2 4-562G REACTOR VESSEL A302 GR.B CS N/A 5.188 86-306-02 LOHER HEAD f1ERIDI0 teal HELD

! B-B VT-2 4-562H REACTOR VESSEL ~A302 GR.B CS N/A ~5.188 86-306-02 l LOHER HEAD

! MERIDI0t4AL HELD REACTOR VESSEL B-C UT 1-574 REACTOR HEAD TO A302 TO A336 228.00 5.188 001674 '

FLAT 4GE 33%

B-C UT 3-563 REACTOR VESSEL TO A302 TO A336 228.00 '7.875 002828 FLAllGE 33%

L REACTOR VESSEL B-D UT 2-566A REACTOR VESSEL TO A302 TO A336 19.25 4.750 001682 IS01 ATIO:4 C0taDEtiSER  ;

I:0ZZL E i B-D UT 2-566B REACTOR VESSEL TO A302 TO A336 19.25 4.750 001683 ISOL ATIO:4 CatIDEllSER

= i;0ZZLE l REACTOR VESSEL r

B-E VT-2 CRD-Pill 3 C0!1 TROL ROD DRIVE SA 182 F304 7.50 1.000 86-306-06 pef 4ETRATI0tt 10-23 5:

  1. w II ' <

NIS-1 OHHERS DATA REPORT FOR INSERVICE INSPECTIDHS PAGE 7 0F 47 JERSEY CENTRAL P0HER AND LIGHT COMPANY

, 1. OHMER: MADISON AVENUE AT PUNCHB0HL ROAD.MORRISTOHN,N.J. 07960 OYSTER CREEK HUCLEAR GEHERATING STATION

2. PLANT: OH U.S. RT.9. 2 MILES SOUTH OF FORKED RIVER,N.J. 08731 3.. UNIT: OYSTER CREEK HUCLEAR GENERATING STATION
4. OGHER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NDHE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD HUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXAM COMP 0HENT COMPONENT HATERIAL COMPONENT COMP 0HENT INSPECTION N M BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMEMMMMMMMMMMMMMMMMMkhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMM REACTOR VESSEL B-E VT-2 CRD-PH14 CONTRC', ROD DRIVE SA 182 F304 7.50 1.000 86-306-06 PENETRATION 14-23 B-E VT-2 CRD-PN15 CONTROL ROD DRIVE SA 182 F304 7.50 1.000 86-306-06 PEHETRATION 26-23 B-E VT-2 CRD-PN16 CONTROL ROD DRIVE SA 182 F304 7.50 1.000 86-306-06 PENETRATION 30-23 B-E VT-2 .CRD-PN17 CONTROL ROD DRIVE SA 182 F304 7.50 1.000 86-306-06 PEHETRATION 42-23 B-E- VT-2 CRD-PH18 CONTROL ROD DRIVE SA 182 F304 7.50 1.000 86-306-06 PEHETRATION 46-23 B-E VT-2 CRD-PN19 CONTROL ROD DRIVE SA 182 F304 7.50 1.000 86-306-06 PEHETRATIDH 02-19 B-E- VT-2 CRD-PN20 CONTROL ROD DRIVE SA 182 F304 7.50 1.000 86-306-06 PEHETRATION 06-19 B-E VT-2 CRD-PN21 CONTROL ROD DRIVE SA 182 F304 7.50 1.000 86-306-06 PD!ETRATION 18-19 B-E VT-2 CRD-PN22 CONTROL ROD DRIVE SA 182 F304 7.50 1.000 86-306-06

.PEHETRATION 22-19' B-E VT-2 CRD-PH23 CONTROL ROD DRIVE SA 182 F304 7.50 1.000 86-306-06 PEHETRATION 34 ""

11 1115-1 OHilERS DATA REPORT FOR IrlSERVICE ItlSPECTIONS PAGE 8 0F 47 JERSEY CErlTRAL PO!!ER At!D LIGHT C0t1 patly

1. Oi!!!ER: MADIS0tl AVENUE AT PutlCHB0HL POAD,MORRISTOHN,N.J. 07960 OYSTER CREEK tlUCLEAR GEllERATIllG STATION
2. PLAtlT* ON U.S. RT.9, 211ILES SOUTH OF FORKED RIVER,N.J. 08731
3. UNIT OYSTER CREEK tlUCLEAR GEllERATIllG STATION
4. O!!!!ER CERTIFICATE OF AUTHORIZATI0t1 (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD nut 1BER FOR UtilT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXArt C0!1P0tlENT Cot 1PONEllT MATERIAL COMPO!!Et1T COMPONENT INSPECTIort M X BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA SHEET M MMMMMMMMMMMMMMMkMMMMMMMMMMhMMMMMMMMMMhMMMkhMMXMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM REACTOR VESSEL B-E VT-2 CRD-PN24 C0ilTROL ROD DRIVE SA 182 F304 7,50 1.000 86-306-06 PEtiETRATI0li 38-49 B-E VT-2 ICT-28-05 IllCORE IllSTRUMEllT N/A N/A fl/A 86-306-16 HOUSIllG-INCORE TUBE (SPARE PENETRATION)

B-E VT-2 INS-Pfl38 INSTRUf1EtlT pet:ETRA- N/A N/A N/A 86-306-04 TIOrl, LOCATED Ill RX VESSEL N0ZZLE 16A B-E VT-2 LPRfi-Pfl43 LOCAL P0HER RANGE N/A N/A N/A 86-306-05 MotiITOR PEllETRATI0tl 17-12 B-E VT-2 LPRM-Pf144 LOCAL P0HER RAtlGE N/A N/A N/A 86-306-05 M0!!ITOR PEllETRATION 17-20

B-E VT-2 LPRM-PN45 LOCAL P0HER RANGE N/A N/A N/A 86-306-05 r10flITOR PEllETRATION 17-28 B-E VT-2 LPRM-Pil46 LOCAL PONER RAllGE N/A N/A N/A 86-306-05 r10flITOR PEllETRATI0tt 17-36 B-E VT-2 LPRil-Pt147 LOCAL PONER RANGE N/A N/A N/A 86-306-05 M0!aITOR PEtlETRATION

== 17-44 B-E VT-2 568-25 REACTOR VESSEL SA105-II CS 3.00 N/A 86-306-03 4- - DRAlt! 110ZZL E

.. . . . _ _. _ _ . . ._ _ _ _ .m. . . _ . . _ . .

Il I

HIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 9 0F 47 i

JERSEY CENTRAL P0HER AND LIGHT COIPANY l 1. OHNER: MADISON AVEtUE AT PUNCHB0!!L ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK FUCLEAR GEllERATItG STATION

2. PLANT: CH U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,H.J. 08731
3. UNIT: OYSTER CREEK iUCLEAR GENERATING STATIDH
4. CHNER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. C0!!MERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD tlUMBER FOR UNIT RX VESSEL 14895 DMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM D SYSTEM SECT.XI EXAtt COUP 0HENT C0!1PONENT MATERIAL COMPONENT COMPONENT INSPECTION M U BOUNTRY- CATEGORY METHOD ID DESCRIPTION SPECIFICATI0H DIAMETER THICKNESS DATA SHEF.T M dM M M M M MM MM M MMMM MMM M M MMM MM MM MM MM MM MM M M M M M M M M M M M M M M M h MMM MM M M M M M M M M M M M MM MM M M M M M M MMMM M M M M M M M M M MMMMM M M M M M M MM MM M M M M MM MM M M M M M MM M M M M M-(M M M M REACTOR RECIRCULATI0tl B-G-1 MT tlG01-A-BG RECIRC.PuttP BOLTIllG A193 GR B7 2.75 16.250 007012

, 16 CAP SCREHS PRE-SERVICE EXAM B-G-1 UT HG01-A-BG RECIRC. PUMP BOLTING A193 GR B7 2.75 16.250 002666 l

16 CAP SCREUS PRE-SERVICE B-G-1 VT HG01-A-BG RECIRC.PUt1P BOLTING A193 GR B7 2.75 16.250 86-310-01 16 CAP SCREll5 PRE-SERVICE EXAt1 l

l REACTOR VESSEL ,

B-G-1 UT 563-02-L23 VESSEL FLAllGE SA336 P5 N/A 7.875 001689 LIGA!!EllT BETHEEN STUD LOCATION B-G-1 UT 563-02-L24 VESSEL FLANGE SA336 P5 N/A 7.875 001689 LIGAMENT BETilEEH STUD LOCATION B-G UT 563-02-L25 VESSEL FLA!1GE SA336 P5 N/A 7.875 001689 LIGAMEllT BETHEEN STUD LOCATION l B-G-1 UT 563-02-L26 VESSEL FLAllGE SA336 P5 N/A 7.875 001689 l LIGAllEllT BETi!EEH STUD LOCATION l

l

== B-G-1 UT 563-02-L27 ' VESSEL FLA!!GE SA336 P5 N/A 7.875 001689 LIGA!!ENT BETHEEN STUD LOCATIOll B-G-1 UT 563-02-L23 VESSEL FLAllGE SA336 P5 N/A 7.875 001689-LIGAttEllT BETHEEN STUD LOCATION l

e

Il 14I5-1 OllllERS DATA REPORT FOR It4 SERVICE INSPECTIONS PAGE 10 0F 47 JERSEY CEllTRAL PONER A!!D LIGHT COMPANY

1. OHilER: MADISUti AVEtlUE AT PUtiCHB0llL ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK #10 CLEAR GEt1ERATING STATI0ll
2. PLAllT Ot1 U.S. RT.9, 2 f1IL ES SOUTH OF FORKED RIVER,N.J. 08731
3. UllI T OYSTER CREEK tlVCLEAR gel 4ERATIt1G STATION
4. Oll!!ER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) fl0NE
5. COMMERICAL SERVICE DATE 12/23/69
6. IIATIONAL BOARD flUMBER FOR UNIT RX VESSEL I4895 M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M MM M M M M M M M M M M M EM M M M MM M M M M M M M M M M M M MM M M M M M M M M M M M M M M M M SYSTEM SECT.XI EXAM COMPONEt4T COMP 0 tee!4T MATERIAL COMPONENT COMPONENT INSPECTION N M BOUT 4TRY CATEGORY METHOD ID DESCRIPTI0fl SPECIFICATI0H DIAMETER THICKNESS DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM REACTOR VESSEL B-G-1 UT 563-02-L29 VESSEL FLAT 1GE SA336 P5 N/A 7.875 001689

.LICAMEllT BETHEEN STUD LOCATION B-G-1 UT 563-02-L30 VESSEL FLAtlGE SA336 P5 ft/A 7.875 001689 LIGAMENT BETHEE!!

S10D LOCATION B-G-1 UT 563-02-L31 VESSEL FLAllGE SA336 P5 N/A 7.875 001689 LIGAMENT BETHEEtt STUD LOCATI0fl B-G-1 UT 563-02-L32 VESSEL FLAtlGE SA336 P5 N/A 7.875 001689 LIGAMENT BETl!EEtl STUD LOCATIO!1 B-G-1 UT 563-02-L33 VESSEL FLAT 3GE SA336 P5 N/A 7.875 001689 LIGAMENT BETHEEN STUD LOCATION B-G-1 UT 563-02-L34 VESSEL FLANGE SA336 P5 N/A 7.875 001689 LIGAtiENT BETilEEN STUD LOCATION-

'B-G-1 UT 563-02-L35 VESSEL FLAtlGE SA336'P5- N/A 7.875 001689 LIGAMEt4T BETHEEN STUD LOCATION B-G-1 UT 563-02-L36 VESSEL FLANGE SA336 P5 N/A 7.875 001689 LIGA!1EllT BETHEEN

-- STUD LOCATI0t1 B-G-1 UT 563-02-L37 VESSEL FLANGE SA336 P5 N/A 7.875 001689 LIGAllEllT BETHEEN STUD LOCATIO!J B-G-1 UT 563-02-L38 VESSEL - FL At!GE SA336 P5 ti/A 7.875 001689 LIGAMENT DETHEEli

== STUD LOCATI0ta

__ . _ ._. <m , . _ _

ll NIS-1 OllilERS DATA REPORT FOR IllSERVICE ItiSPECTIONS PAGE 11 0F 47 JERSEY CEllTRAL P0HER At3D LIGHT COMPAtlY

1. OllNER: MADISON AVErlUE AT PUNCHB0!!L ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK tlVCLEAR GEllERATIrlG STATI0ll
2. PLANT 2 011 U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,H.J. 08731
3. UNIT: OYSTER CREEK llUCLEAR GEllERATING STATION
4. DMNLR CERTIFICATE OF AUTHORIZATION (IF-REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. IIATI0llAL BOARD flUMBER FOR UllIT RX VESSEL 14895 DMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM u SYSTEM SECT.XI EXAH COMPONEllT COMP 0tlElli MATERIAL COMP 0tlENT COMPONEllT INSPECTION M D BOUtlTRY CATEGORY METHOD ID DESCRIPTIOil SPECIFICATION DIAMETER THICKNESS DATA SHEET M DMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMkMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMEMMMMkMMM REACTOR VESSEL B-G-1 UT 563-02-L39 VESSEL FLANGE SA336 P5 ll/A 7.875 001689 LIGAMEllT BETHEEft STUD LOCATI0rl B-G-1 UT 563-02-L40 VESSEL FLANGE SA336 P5 N/A 7.875 001689 LIGAMEllT BETilEUI STUD LOCATIO!1 B-G-1 UT '563-02-L41 VESSEL FLAtlCE SA336 PS 11/A 7.875 001689 LIGAMEllT BETilEEtl STUD LOCATIOli B-G-1 UT 563-02-L42 VESSEL FLANGE SA336 PS N/A 7.875 001689 LIGAMElli BETl!EEN STUD LOCATIDH B-G-1 UT 563-02-L43 VESSEL FLA!!GE SA336 P5 N/A 7.875 001689 LIGAMEllT BETMEEli STUD LOCATI0tt B-G-1 UT 563-02-L44 VESSEL'FLAllGE SA336 P5 N/A 7.875 001689 LIGAMEllT BETHEEN STUD LOCATI0tl B-G-1 UT 573-01-1 VESSEL FLAllGE A193 GR.A151- 6.25 54.875 002656 CLOSURE STUD B-G-1 UT 575-01-5 VESSEL FLANGE 'A193 GR.A151 6.25 54.875 002656 CLOSURE. STUD B-G-1 UT 573-01-7 VESSEL FLAtlGE A193 GR.A151 6.25 .54.875 002656 CLUSURE STUD B-G-1 UT 573-01-26 VESSEL FLAtlGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD

ll flIS-1 OltNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 12 0F 47 JERSEY CEllTRAL P0HER AND LIGHT COMPAt1Y

1. OWNER: t1ADISON AVENUE AT PUtlCHB0HL ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK IJUCLEAR GENERATIllG STATI0tl
2. PLANT: Gil U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,H.J. 08731
3. UNIT OYSTER CREEK NUCLEAR GENERATING STATI0tl
4. O!!:lER CERTIFICATE OF AUTHORIZATI0tl (IF REQUIRED) NONE
5. COHt1ERICAL SERVICE DATE 12/23/69
6. NATI0tlAL BOARD NUMBER FOR UllIT RX VESSEL 14895 DMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM 0 SYSTEM SECT.XI EXAM COMP 0flEtlT COMP 0tlEtJT MATERIAL COMP 0t1ENT COMPONENT INSPECTION N D BOUNTRY CATEGORY llETHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA SHEET M OMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM REACTOR VESSEL B-G-1 UT 573-01-27 VESSEL FLANGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD B-G-1 UT 573-01-28 VESSEL FLANGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD B-G-1 UT 573-01-29 VESSEL FLAllGE A193 GR.A151 6.25 54.875 002456 CLOSURE STUD B-G-1 UT 573-01-30 VESSEL FLAllGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD B-G-1 UT 573-01-31 VESSEL FLAtlGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD B-G-1 UT 573-01-32 VESSEL FLANGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD B-G-1 UT 573-01-33. VESSEL FLANGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD B-G-1 UT 573-01-34 VESSEL FLANGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD

. B-G-1 UT 573-01-35 VESSEL FLAtlGE A193 GR.A151 6.25 54.875 ~002656 1 CLOSURE STUD B-G-1 UT 573-01-36 VESSEL FLANGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD 7:

ll NIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 15 0F 47.

2' JERSEY CENTRAL P0llER Af3D LIGHT COMPAllY -

1. OHNER: MADIS0tl AVEllUE AT PUtlCHB0HL ROAD,MORRISTOHN,N.J. 07960 J OYSTER CREEK tlUCLEAR GEtERATING STATION
2. PLAtlT: O!! U.S. RT.9. 2 t11LES SOUTH OF FORKED RIVER,N.J. 08731
3. UrlIT: OYSTER CREEK t!UCLEAR GEtlERATIllG STATI0rl
4. OHilER CERTIFICATE OF AUTHORIZATI0tl (IF. REQUIRED) NONE 5..ColtMERICAL SERVICE DATE 12/23/69
6. NATIOllAL BOARD flu tBER FOR UtlIT RX VESSEL 14895 DMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM D SYSTEM SECT.XI EXAt1 COMP 0tlEllT - C0r:P0tlENT 11ATERIAL COMPONENT COMPONEllT INSPECTION M D BOUllTRY CATEGORY METHOD ID DESCRIPTI0tl ' SPECIFICATION DIAMETER THICKNESS DATA SHEET M- t DMMMMMMMMMMMMMMMMKkMMMMMMMMMMMMMMMMkMMMMMMMMMhMMMMMMMMMMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM

. REACTOR VESSEL-

)

i B-G-1 UT 573-01-37 VESSEL FLANGE A193 GR.A151 6.25 54.875 002656

[ CLOSURE STUD i

B-G-1 UT 573-01-38 VESSEL FLANGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD r

B-G-1 UT 573-01-39 VESSEL FLAtlGE A193 GR.A151 6.25 54.875 002656 4 CLOSURE STUD B-G-1 UT 573-01-40 VESSEL FLAllGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD ~

.B-G-1 UT' 575-01-41 VESSEL FLAllGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD B-G-1 ' UT 573-01-42' VESSEL FLAllGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD B-G-1 UT -573-01-43' VESSEL FLAllGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD i

a- B-G-1 UT 573-01-44 VESSEL FLANGE A193 GR.A151 6.25 54.875 002656 CLOSURE STUD B-G-1 VT- .573-01 REACTOR VESSEL SA193 GR.A151 6.25- '54.875 86-002-158 CLOSURE STUD

-B-G-1 .VT 573-01-48 REACTOR VESSEL SA195 GR.A151 6.25- 54.875 86-002-158 CLOSURE STUD

.l

. _ _ . . ._m . . - - .~ __ __ . _ _ . . . _ - - - . . _ _ _ - - _

l' ll NIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 14 ' 0F 47' JERSEY CENTRAL POWER AND LIGHT CONPANY

1. OHNER MADISON AVENUE AT PUNCHB0HL-ROAD,MORRISTOWN,N.J. 07960 OYSTER CREEK HUCLEAR GENERATING STATION
2. PLANT: ON U.S. RT.94 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UNIT OYSTER CREEK NUCLEAR GENERATING STATION
4. CHNER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD NUMBER FOR UNIT RX VESSEL 14895 DMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM.

U SYSTEM SECT.XI EXAM COMPONENT. COMPONENT MATERIAL COMPONENT COMPONENT INSPECTION M n BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS- DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM

' REACTOR VESSEL B-G-1 VT 573-01-49 REACTOR VESSEL SA193 GR.A151 6.25 54.875 86-002-158 CLOSURE STUD

! SA193 GR.A151 B-G-1 VT 573-01-50 REACTOR VESSEL 6.25 54.875 86-002-158.

l CLOSURE STUD i BiG MT 573-02-47 REACTOR VESSEL SA193 GR.A151 N/A N/A 006120 CLOSURE NUT l

B-G-1 VT 573-02-47 REACTOR VESSEL SA193 GR.A151 N/A N/A 86-002-157 CLOSURE NUT I ~

B-G-1 MT 575-02-48 REACTOR VESSEL SA193 GR.A151 N/A N/A- 006120 CLOSURE NUT B-G-1 'VT 573-02-43 REACTOR VESSEL SA193 GR.A151 N/A N/A' 86-002-157' CLOSURE NUT B-G-l' MT 573-02-49 REACTOR VESSEL SA193 GR.A151 N/A N/A- 006120 CLOSURE NUT 86-002-157

~

, B-G-1 VT. '

573-02-49 REACTOR VESSEL- SA193 GR.A151 N/A N/A L CLOSURE NUT l- B-G-1 MT 575-02-50 ' REACTOR VESSEL SA193 GR.A151 N/A N/A 006120 i

CLOSURE NUT B-G-1 . VT- 573-02-50 REACTOR VESSEL SA193 GR.A151- N/A N/A 86-002-157 CLOSURE NUT

j. m I

tlIS-1 Ol!!1ERS DATA REPORT FOR IllSERVICE INSPECTIONS PAGE 15 0F 47.

JERSEY CEtlTRAL P0HER AllD LIGHT COMPANY

1. OHilER: flADIS0tl AVENUE AT PullCNB011L ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK NUCLEAR GEllERATIllG STATI0tl
2. PL AtlT : Gil U . S . RT 9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UtlIT : OYSTER CREEK tlVCLEAR GENERATIllG STATI0tl
4. O!!!!ER CERTIFICATE OF AUTHORIZATI0tl (IF REQUIRED) NONE
5. COM;1ERICAL SERVICE DATE 12/23/69
6. IIATI0llAL BOARD flUMBER FOR UtlIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMXMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXAll C0!!PONENT C0i1PO!!EllT MATERIAL COMPONENT Cat 1PONEllT INSPECTI0tl M M BOU!ITRY ' CATEGORY METHOD ID DESCRIPTI0tl SPECIFICATIOli DIAMETER THICKNESS DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMAAMMhMMMMMMkMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMX REACTOR VESSEL B-G-1 VT 573-06-47 REACTOR VESSEL SA193 GR.A151 N/A N/A 86-002-165 CLOSURE BUSHING B-G-1 VT 573-06-48 REACTOR VESSEL SA193 GR.A151 N/A N/A 86-002-165 CLOSURE BUSHING B-G-1 VT 573-06-49 REACTOR VESSEL SA193 GR.A151 N/A N/A 86-002-165 CLOSURE BUSHIllG B-G-1 VT 573-06-50 REACTOR VESSEL SA193 GR.A151 N/A N/A 86-002-165 CLOSURE BUSHIllG B-G-1 VT 573-07-47 REACTOR VESSEL SA193 GR.A151 N/A N/A 86-002-157 CLOSURE HASHER B-G-1 VT 573-07-48 REACTOR VESSEL SA193 GR.A151 N/A N/A 86-002-157 CLOSURE HASHER B-G-1 VT. 573-07-49 REACTOR VESSEL SA193 GR.A151 N/A N/A 86-002-157 CLOSURE HASHER B-G-1 VT 573-07-50 REACTOR VESSEL SA193 GR.A151 N/A N/A 86-002-157 CLOSURE HASHER B-G-1 VT 573-08-47 REACTOR VESSEL SA193 GR.A151 N/A. N/A 86-002-157 CLOSURE HASHER B-G-1 VT 575-08-48 REACTOR VESSEL SA193 GR.A151 N/A N/A 86-002-157 CLOSURE HASHER

~

5:

II '

l l: HIS-1 OHHERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 16 0F 47 l JERSEY CENTRAL P0HER AND LIGHT COMPANY l 1. OHNER: MADISON AVENUE AT PUNCHBOUL ROAD,MORRISTOUN,N.J. 07960

. OYSTER CREEK NUCLEAR GENERATING STATION i 2. PLANT: ON U.S. RT.9, 2 r1ILES SOUTH OF FORKED RIVER,N.J. 08731

3. UNIT: OYSTER CREEK HUCLEAR GENERATING STATION
4. O!!HER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD HUMBER FOR UNIT RX VESSEL 14895 DMMMMMMMMMMMMMMXMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM' O. SYSTEM SECT.XI EXAM C0f1P0HENT COMP 0HEHT MATERIAL COMPONEllT COMPONENT INSPECTION M n BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKHESS DATA SHEET M UMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMhMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMM REACTOR VESSEL l

B-G-1 VT 575-08-49 REACTOR VESSEL SA193 GR.A151 N/A N/A' 86-002-157 CLOSURE HASHER B-G-1 VT 573-08-50 REACTOR VESSEL SA193 GR.A151 N/A N/A 86-002-157 CLOSURE ilASHER REACTOR HEAD COOLING B-G-2 VT RHC-2-BG2 FLANGE BOLTING SA182 F304 0.88 N/ A - 86-002-182 REACTOR HEAD VENT' B-G-2 VT RHV-MV-BG2 FLANGE BOLTING CARBON STEEL 0.88 N/A 86-002-180 REACTOR VESSEL B-G-2 VT 576-01-BG REACTOR HEAD VENT SA182 F304 1.25 N/A 86-002-181 FLANGE BOLTlHG

-B-G-2 VT 576-07-BG, REACTOR HEAD COOLING SA182 F304 0.75 N/A 86-002-184 FLANGE BOL1ING

== REACTOR VESSEL B-H UT 569- SUPPORT SKIRT TO SA336-SA302 N/A- 1.000 001676 BOTTOM HEAD HELD 33%

B-n UT 7-569 SUPPORT SKIRT HELD SA336-SA212 B 202.00 .1.625 001677 33%

7

. - . ~ . . - . .

. _,.._.~_~. . . - . - - - - . ... . . . . .

f.

J 11 NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 17 0F 47-JERSCY CENTRAL POWER AND LIGHT COMPANY

1. OHNER: MADISON AVENUE AT PUNCHB0HL ROAD.MORRISTOHN,N.J. 07960 OYSTER CREEK tlUCLEAR GENERATING STATION
2. PLANT: OH U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731 i 3. UNIT: OYSTER CREEK NUCLEAR GENERATING STATION
4. OWNER CEFTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD NUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMAMMMMMMMMMKMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXAM COMPONENT COMPONENT MATERIAL COMPONENT COMPONENT- . INSPECTION M J

M BOU!iTRY' CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA SHEET M-MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM ISOLATION CONDENSER B-J UT HE-5-2 CIRC. PIPING HELD A312 SS 10.00 0.593 002822 B-J UT. HE-5-3 CIRC. PIPING HELD A312 SS 10.00 0.593 002823 B-J UT NE-5-22A CIRC. PIPING HELD A312 SS 10.00 0.593 002821 B-J UT NE-5-23 CIRC. PIPING HELD A312 SS 10.00 0.593 002819 B-J- PT NE-5-30 BRANCH PIPING HELD A312 SS 1.00 N/A 007605 REACTOR RECIRCULATION B-J : UT -IIG-A-1A CIRC. PIPING HELD A312 SS- 26.00 1.219 002722 B-J PT HG-B BRANCH PIPING HELD A312 SS 1.00 N/A 007502

== ' B-J UT NG-B-17 CIRC. PIPING HELD A312 SS 26.00 '1.219 002637 B-J UT HG-B-23 CIRC. PIPING HELD. A312 SS 26.00 1.219 002639 7

11 HIS-1 ONNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 18 0F 47.

JERSEY CENTRAL PONER AND LIGHT COMPANY

1. OHNER: MADISON AVENUE AT PUNCNB0HL ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK NUCLEAR GENERATING STATION
2. PLANT: OH U.S. RT.9, 2 HILES SOUTH OF FORKED RIVER,N.J. 08731
3. UNIT: OYSTER CREEK NUCLEAR GENERATING STATION
4. OHNER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD NUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M: SYSTEM SECT.XI EXAM COMPONENT COMPONENT . MATERIAL COMPONENT COMPONENT INSPECTION M M BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMmMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMX REACTOR RECIRCULATIDH B-J UT NG-B-24A CIRC. PIPING HELD A312 SS 26.00 1.219 002706 B-J UT NG-C-4 CIRC. PIPING HELD A312 SS 26.00 1.219 001989 B-J VT-2 NG-C-17 HELD DVERLAY REPAIR A312 SS 26.00 1.219 86-306-18 SYSTEM LEAKAGE TEST PRE-SERVICE EXAM B-J UT NG-C-17 HELD OVERLAY REPAIR A312 SS 26.00 1.219 001696 PRE-SERVICE EXAM B-J VT-2 NG-C-23 HELD DVERLAY REPAIR A312 SS 26.00 1.219 86-306-18 SYSTEM LEAKAGE TEST PRE-SERVICE EXAM B-J UT HG-C-23 HELD OVERLAY REPAIR A312 SS. 26.00 1.219 001692 PRE-SERVICE EXAM -

B-J UT NG-C-23A CIRC. PIPING HELD A312 SS 26.00 .1.219 002707 B-J UT NG-D-4 CIRC. PIPING HELD A312 SS 26.00 1.219 001990

-B-J PT HG-D-19 BRANCH PIPING HELD' A312 SS 1.00 N/A 86-005-05 B-J UT NG-E-6 CIRC. PIPING HELD A312 SS 26.00. 1.219 001987 7

F l

l l

l ll f4IS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 19 0F 47 JERSEY CEllTRAL POWER AND LIGHT C0t1PANY

1. OHNER MADIS0tl AVEllUE AT PUtiCHB011L ROAD,MORRISTOWN,N.J. 07960 OYSTER CREEK tlUCLEAR GENERATING STATION
2. FLAtlT: Oil U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UtlIT OYSTER CREEK tlUCLEAR GttlERATING STATION
4. OHilER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) Nat4E
5. COI-ti1ERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD i4UI1BER FOR UllIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI . EXAM Col 1PollEllT COMP 0ilEllT MATERIAL COMPONENT COMP 0tlEtli IllSPECTION M l M BOUllTRY CATEGORY METHOD ID DESCRIPTI0tl SPECIFICATION DIAMETER THICKNESS DATA SHEET M l nMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM REACTOR RECIRCULATI0tl B-J PT tlG-E-14 BRANCH PIPIrlG llELD A312 SS 1.00 il/A 007502 B-J UT tlG-E-17 CIRC.PIPIllG HELD A312 SS 26.00 1.219 001630 B-J PT tlG-E-18 BRAtlCH PIPING llELD A312 SS 2.00 N/A. 86-003-05 B-J UT .flG-E-23 BRANCH PIPING HELD A312 SS 14.00 0.800 002813 B-J UT NG-E-25 CIRC. PIPIT 4G HELD A312 SS 26.00 1.219 002560 LIQUID POISON

'B-J VT-2 flP-HYDRO HYDROSTATIC TEST A312 SS N/A N/A 86-306-24 B-J UT tlP-2-33 IllTEGRALLY llELDED A312 SS 1.50 0.185 002837 PEllETRATION TO PIPE

== B-J PT NP-2-41 SOCKET HELD A312 SS 1.50 0.200 005803 SHUTDallia C00LIllG B-J UT tlU-1-1 CIRC.PIPIllG HELD A106 CS 14.00 0.750 002841

i 11 -

HIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 20 0F 47 JERSEY CENTRAL P0HER AND LIGHT C0tlPANY

1. OllNER: MADISON AVENUE AT PUNCNB0HL ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK tlUCLEAR GEllERATING STATI0t1
2. PLANT: O!I U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UllIT: OYSTER CREEK NUCLEAR GENERATING STATION
4. Ol!!IER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. COMi1ERICAL SERVICE DATE 12/23/69
6. IIATIONAL BOARD flVMBER FOR UNIT RX VESSEL 14895 DMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM D SYSTEM SECT.XI EXAM COMPONENT C0!!PONElli MATERIAL COMPONENT COMPONENT INSPECTION M D BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA SHEET M DMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM)MMMMMMMMMMMMMMMMMMkMM SNUTDOHN COOLING B-J UT tiu-1-4 CIRC. PIPING HELD A106 CS 14.00. 0.750 002630 1

B-J UT 110-1-13 CIRC. PIPING HELD Alu' CS 14.00 0.750 002629 B-J I1T NU-1-20A BRANCH PIPING HELD A106 CS 1.00 N/A 86-003-04 B-J UT tiu-1-32 CIRC. PIPING HELD A106 CS 10.00 0.594 001680 B-J UT NU-1-36 CIRC. PIPING HELD A106 CS 14.00 0.750 002801-B-J UT NU-1-42 CIRC. PIPING HELD. A106 CS 10.00 0.594- 002807 B-J UT 11U-4-2 CIRC.PIPIllG HELD A312 SS 10.00 0.594 002840 CORE SPRAY

== B-J UT tlZ-3-34 CIRC.PIPIllG HELD A312 SS 8.00 0.500 002507 B-J UT NZ-3-42 CIRC'PIPIllG HELD

. A312 SS 8.00 05500 002826 l

- .-- . . . _ - , - . - . - . . - . . .-. - - - . - - - _- - - . ~

11 NIS-I OHilERS DATA REPORT FOR IllSERVICE INSPECTIONS PAGE 21 0F 47-JERSEY CEllTRAL Poller AND LIGHT COMPAtlY

1. OllllER: MADIS0tt AVErlUE AT PUNCHB0HL ROAD,MORRIST0Hil,N.J. 07960 OYSTER CREEK tlVCLEAR GENERATIllG STATIDH
2. PL AtlT : Oil U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UllIT : OYSTER CREEK #1UCLEAR GEllERATING STATION
4. OllflER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. C0l*J4ERICAL SERVICE DATE 12/23/69 ,
6. NATIONAL BOARD flUMBER FOR UNIT RX VESSEL 14895 GMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMmMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM u SYSTEM SECT.XI EXAM COMP 0tlENT COMP 0tlENT MATERIAL COMPONENT COMPONENT. INSPECTION M O BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA SHEET M CMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMX CORE SPRAY B-J UT NZ-3-58 LONG.PIPI!1G HELD A312 SS 8.00 0.500 001666 B-J UT NZ-3-61 CIRC. PIPING HELD A312 SS 8.00 L0.500 001968 l B-J UT NZ-3-74 CIRC. PIPING HELD A312 SS 8.00 0.500 002547 B-J UT NZ-3-91 CIRC. PIPIT 1G HELD A312 SS 8.00 0.500 002613 REACTOR HEAD VENT B-J PT MV-002 SOCKET llELD A106 2.00 N/A 006302 PRE-SERVICE EXAM B-J PT MV-003 SOCKET HELD A106 2.00 N/A 006302
- PRE-SERVICE EXAM B-J. PT MV-004 SOCKET !! ELD A106 2.00 N/A 006543 PRE-SERVICE EXAM

- == B-J PT MV-005 SOCKET HELD- A106+ 2.00 N/A 006302 PRE-SERVICE EXAt1 B-J PT -MV-006 SOCKET HELD A106 2.00 N/A 006559 PRE-SERVICE EXAM

~~

'1 e ++ _ ___- + ---__.______m_ _ _ _ _

ll HIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 22 0F 47 JERSEY CENTRAL P0HER AND LIGHT COMPANY

1. ONHER: MADISON AVENUE AT PUNCHB0HL ROAD.MORRISTOHN,N.J. 07960 OYSTER CREEK NUCLEAR GENERATING STATION
2. PLANT: OH U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UNIT: OYSTER CREEK HUCLEAR GENERATING STATION
4. OHNER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD HUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMFMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXAM COMPONENT COMPONENT MATERIAL COMPONENT COMPONENT INSPECTION M M BOUNTRY CATEGORY METHOD ID DESCRIPTIDH SPECIFICATION DIAMETER THICKHESS DATA SHEET M MMMMMMMMMMMMMMMMMMhMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMkWMMMM REACTOR HEAD VENT B-J PT HV-007 SOCKET HELD A106 2.00 N/A - 006559 PRE-SERVICE EXAM B-J PT MV-012 SOCKET HELD A106 2.00 N/A 006536 PRE-SERVICE EXAM B-J VT-2 RHV-HYDRO REACTOR HEAD FLANGE CARBON STEEL 0.88 N/A 86-306-20 HEAD VENT FLANGE HEAD VENT LINE, PSI ISOLATION CONDENSER B-K-1 UT NE-150-1-H CLEVIS HELDED STAIN. STEEL N/A N/A 002631 ATTACHMENT PRE-SERVICE EXAM B-K-1 UT NE-151-1-H CLEVIS HELDED STAIN. STEEL N/A N/A 001991 ATTACHMENT PRE-SERVICE EXAM B-K-1 UT NE-2-S6 SHUBBER MECHANICAL STAIN. STEEL 10.00 0.593 002825 INTEGRALLY HELDED B-K-1 UT HE-5-S3 SHUBBER MECHANICAL STAIN. STEEL 10.00 0.593 002824 INTEGRALLY HELDED

== LIQUID POISON B-K-1 UT HP-2-30 PEHETRATION A312'SS 6.00 0.445 001699 SUPPORT BASELINE EXAM i

11 flIS-1 OHNERS DATA REPORT FOR IllSERVICE INSPECTIONS PAGE 23 0F 47 JERSEY CEllTRAL PONER AND LIGHT COMPANY

1. OllflER: tIADISON AVENUE AT PUNCHB0llL ROAD,MORRIST0HN,N.J. 07960 OYSTER CREEK llVCLEAR GEllERATIrlG STATION
2. PLANT: Off U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08751
3. Ut1IT: OYSTER CREEK lluCLEAR GENERATIllG STATI0tl
4. OHilER CERTIFICATE OF AUTHORIZATI0tt (IF REQUIRED) IJONE
5. COM?iERICAL SERVICE DATE 12/23/69
6. NATI0tlAL BOARD llUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXArt COMPONElli COMP 0tlENT MATERIAL COMPONENT COMPONENT INSPECTION M M BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATI0H DIAMETER THICKNESS DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMRMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMM SHUTDOHil C00LIrlG B-K-1 UT NU-1-H5 PENETRATION A106 CS ti/A N/A 002723 SUPPORT CORE SPRAY B-K-1 UT NZ-3-H4 HANGER VARIABLE STAIN. STEEL 8.00 0.481 002508 SPRING HELDED l B-K-1 UT NZ-3-H7 SUPPORT VARIABLE STAIN. STEEL 8.00 0.481 002554 SPRING HELDED PRE-SERVICE EXAM B-K-1 Ur flZ-3-S3 SilVBBER MECHAllICAL STAIN. STEEL 8.00 0.481. 002509 IllTEGRALLY llELDED MAIN STEAM B-K-2 VT MS-1-H2 SUPPORT VARIABLE A106 B N/A N/A 86-002-126 SPRIllG B-K-2 VT MS-1-H3A HAtlGER VARIABLE A106 B N/A N/A 86-002-163 SPRIllG B-K-2 VT MS-1-H9 SUPPORT VARIABLE A106 B N/A N/A- 86-002-161 SPRIllG B-K-2 VT MS-1-H10 HANGER VARIABLE A106 B N/A N/A 86-002-37 SPRIllG B-K-2 VT MS-1-56 SNUBBER MECHANICAL A106 B' N/A N/A 86-002-34 IllTEGRALLY HELDED

~~

I

_- _. . - . - , .- . -.. - -- - - . .n . _ .- . . ~ - . - -. - . .

i 111S-1 OlitiERS DATA REPORT FOR IllSERVICE INSPECTI0 tis PAGE 24 0F 47

. JERSEY CEllTRAL P0llER At3D LIGHT COMPAt4Y-

1. OHtiER: ftADIS0!i AVEt1UE AT PUNCHB0HL ROAD,MORRIST0HN,H.J. 07960 OYSTER CREEK tlUCLEAR GEllERATIl1G STATI0ll
2. PLANT: Oil U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08751
3. Uti!T OYSTER CREEK tlUCLEAR GErlERATIllG STATI0tl
4. ONt1ER CERTIFICATE OF AUTHORIZATI0t1 (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATi0!lAL BOARD tlUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMFMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMNMM u SYSTEM SECT.XI EXAM COMP 0!iEtJT COMP 0tlE!1T MATERIAL COMPONENT -COMPONEllT INSPECTION M U BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER . THICKtiESS DATA SHEET M UNMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMkMMAMMMMMhMMMMMMMMMMMMhMMMMMMMMMMMMMMkMMMMMhkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM l

MAlti STEAM B-K-2 VT MS-1-S7 SNUBBER MECHAtlICAL A106 B N/A N/A. 86-002-30 B-K-2 VT MS-1-S10 St4UBBER MECHAllICAL A106 B N/A N/A 86-002-36 ,

B-K-2 VT 115 S 1 3 StiUBBER MECHAf4ICAL A106 B N/A N/A 85-026-46 B-K-2 VT MS-1-S14 SNUBBER MECHAllICAL A106 B N/A N/A 85-026-47~

CONTROL ROD DRIVE HYDRAULIC ,

B-K-2 VT NC-2-H1 SUPPORT , CotiSTAllT CARBON STEEL N/A N/A 005944 ,

LOAD B-K-2 VT NC-4-H3 RESTRAltlT RIGID STAIll. STEEL N/A N/A. 86-002-89

, B-K-2 VT tlc-4-H7 HAtlGER VARIABLE STAIN. STEEL N/A N/A- 005944 SPRIrlG

== B-K-2 VT tlc-4-H9 HAtlGER VARIABLE STAIN. STEEL ti/A N/A 005944 SPRIllG CLEANUP DEMINERALIZER B-K-2 VT tlD-1-H3 HANGER VARIABLE STAIN. STEEL N/A N/A 005942 SPRIT 4G .

a J

11 HIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 25 0F 47-JERSEY CENTRAL P0HER AND LIGHT COMPANY

1. OHNER: MADISON AVENUE AT PUNCHB0HL ROAD,MORRISTOHN,N.J. 07960 CYSTER CREEK HUCLEAR GENERATING STATION
2. PLANT: OH U.S. RT.9, 2 HILES SOUTH OF FORKED RIVER,N.J. 08751
3. UNIT: OYSTER CREEK HUCLEAR GENERATING STATION
4. OhuER CERTIFICAIE OF AUTHORIZATION (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. HATIONAL BOARD HUMBER FOR UNIT RX VESSEL 14895 hMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMX -

M SYSTEM SECT.XI EXAM COMP 0HENT COMP 0HCHT MATERIAL COMPONENT COMPONENT INSPECTION M M BOUNTRY CATEGORY HETHOD ID DESCRIPTION SPECIFICATI0H DIAMETER THICKNESS DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM CLEANUP DEMINERALIZER B-K-2 VT ND-1-H4 HANGER VARIABLE STAIN. STEEL N/A N/A 005942 SPRING B-K-2 VT ND-1-H5 RESTRAINT RIGID STAIN. STEEL N/A N/A 005942 B-K-2 VT ND-1-H6 SUPPORT VARIABLE STAIN. STEEL N/A N/A 85-026-36 SPRING B-K-2 VT HD-1-H7 HANGER VARIABLE STAIN. STEEL N/A N/A 85-026-37 4 SPRING l

B-K-2 -VT HD-10-H3 HANGER VARIABLE STAIN. STEEL N/A N/A 86-002-33 SPRING B-K-2 VT ND-10-H4 HANGER VARIABLE STAIN. STEEL N/A N/A 005942 SPRING B-K-2 VT HD-10-H5 RESTRAINT RIGID STAIN. STEEL N/A N/A 005942 ISOLATION CONDENSER

== B-K-2 PT NE-150-1-H CLEVIS HELDED STAIN. STEEL N/A N/A 007617 ATTACHMENT 4

PRE-SERVICE EXAM B-K-2 PT HE-151-1-H CLEVIS HELDED- STAIN. STEEL N/A N/A 007557 ATTACHMENT PRE-SERVICE EXAM T

j

._ . .- . _ _ - . . . .- . . . . - - - - ~ , - . . . - . _ _ . ~ - - . _ . . - . - -.- . . ,

11 I

NIS-I OH!1ERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 26 0F 47 JERSEY CENTRAL FO!!ER AND LIGHT COMPANY

1. OWNER
  • MADIS0tl AVEt4UE AT PUNCHB0HL ROAD MORRISTOHN,N.J. 07960 OYSTER CREEK tlUCLEAR GENERATIllG STATI0t1
2. PL AtlT : ON U.S. RT.9. 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UNIT 2 OYSTER CRE2K tlUCLEAR GENERATING STATION
4. OL!!1ER CERTIFICATE OF AUTHORIZATI0ft (IF REQUIRED) N0!iE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATI0tlAL BOARD I3 UMBER FOR UNIT RX VESSEL 14895' MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXAM COMP 0tiEtiT COMPONENT MATERIAL COMPONENT COMPONENT INSPECTION M M BOUllTRY CATEGORY METHOD ID DESCRIPTI0t1 SPECIFICATI0H DIAMETER THICKt4ESS DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMKEMMMMMMMMMMMMMMkWMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM ISOLATION C0t3DEllSER i B-K-2 VT tlE-2-H2 HANGER VARIABLE STAIN. STEEL N/A N/A 005945 SPRIT 1G (2)

]

B-K-2 VT HE-2-H12 HANGER VARIABLE STAIN. STEEL N/A N/A 86-051-166 SPRIllG B-K-2 VT tlE-2-H19 HAllGER VARIABLE STAIN. STEEL N/A N/A '86-002-99 SPRIllG .

, B-K-2 VT NE-2-H2O HAllGER VARIABLE STAIN. STEEL N/A N/A- 86-002-97 SPRItiG B-K-2 VT NE-2-S6 SituBBER MECHAllICAL STAIN. STEEL N/A N/A 86-002-86

' INTEGRALLY llELDED  ;

B-K-2 VT flE-2-S7 SilVBBER MECHAtlICAL STAIN. STEEL N/A N/A 86-002-85 i

't

-B2 K-2 VT tlE-5-N3 HAtlGER VARIABLE STAIN. STEEL N/A N/A 86-002-197 SPRING B-K-2 VT 14E-5-53 SNUBBER MECHAllICAL STAIN. STEEL N/A N/A 86-002-88 If41EGRALLY !!ELDED B-K-2 VT NE-5-S4 SilUBBER MECHANICAL STAIN. STEEL N/A N/A 86-002-87 It4TEGRALLY HELDED 7

J

- r r

3 11 NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 27 0F 47 JERSEY CENTRAL P0HER AND LIGHT COMPANY

1. OHNER: MADISON AVENUE AT PUNCHB0HL ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK HUCLEAR GENERATING STATION
2. PLANT: OH U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UNIT: OYSTER CREEK HUCLEAR GENERATING STATION
4. OHHER CERTIFICATE OF AUTHORIZATIDH (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD HUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXAM COMP 0HEHT COMPONENT MATERIAL COMPONENT COMPONENT INSPECTION X M BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA SHEET M MMMMMMMMMMMMMkMMMMMMMMMMXhMMMMMMMMMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhWMMMMMMMMMMMMMMMMMMMMM REACTOR RECIRCULATION B-K-2 VT HG-A-H1 HANGER VARIABLE STAIN. STEEL N/A N/A 86-002-91 .

SPRING (2)

B-K-2 VT NG-A-H10 HANGER VARIABLE STAIN. STEEL N/A N/A 86-002-90 SPRING (2)

B-K-2 VT NG-A-51 SHAY BRACE RESTRAINT STAIN. STEEL N/A N/A 86-002-92 INTEGRALLY HELDED B-K-2 VT NG-A-S8 SHAY BRACE RESTRAINT STAIN. STEEL N/A N/A 86-002-101 INTEGRALLY HELDED B-K-2 VT NG-A-S9 SHAY BRACE RESTRAINT STAIN. STEEL N/A N/A 86-002-100 INTEGRALLY HELDED B-K-2 VT HG-B-H1 HANGER VARIABLE STAIN. STEEL N/A N/A 86-002-66 SPRING (2)

B-K-2 VT NG-B-H3 HANGER CONSTANT LOAD STAIN. STEEL N/A N/A 86-002-68 IHIEGRALLY HELDED B-K-2 VT HG-B-H12 HANGER VARIABLE STAIN. STEEL N/A N/A 86-002-138 SPRING HELDED B-K-2 VT HG-B-51 SHAY BRACE RESTRAINT STAIN. STEEL N/A N/A 86-002-64 IHIEGRALLY HELDED B-K-2 VT HG-B-58 SHAY BRACE RESTRAINT STAIN. STEEL N/A .N/A 86-002-65 IHTEGRALLY HELDED

==

_____m._...-- . _ _ . _ .

_ . _ . . . _ . _ _ ~ ~ _ - _ _ - _ _ . _ _ _ _ . _ . , _ _ _ . . -, _ ,

il 4

NIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 28 0F 47. -

JERSEY CENTRAL POHER AND LIGHT COMPANY

1. OWNER: MADISON AVENUE AT PUNCHB0HL ROAD,HORRISTOHN,N.J. 07960 OYSTER CREEK HUCLEAR GENERATING STATION

, 2. PLANT: ON U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08751

3. UNIT: OYSTER CREEK NUCLEAR GENERATING STATION 4 OHNER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69

, 6. NATIONAL BOARD HUMBER FOR UNIT RX VESSEL 14895 CMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM~

C SYSTEM SECT.XI EXAM COMPONENT COMPONENT ttATERIAL COMPONENT COMPONENT INSPECTION N-  !

i U- BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA SHEET M  !

q UMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM 2

REACTOR RECIRCULATION B-K-2 VT NG-D-H4 HANGER VARIABLE STAIN. STEEL N/A N/A 86-002-121 SPRING COUNTERPOISE i

B-K-2 VT NG-D-HS HANGER VARIABLE STAIN. STEEL N/A N/A 86-002-122 SPRING COUNTERPOISE ,

B-K-2 VT NG-D-H6 HANGER VARIABLE STAIN. STEEL N/A N/A 86-002-123-SPRING COUNTERPOISE B-K-2 VT NG-D-H7- HANGER VARIABLE STAIN. STEEL N/A N/A 86-002-124 SPRING COUNTERPOISE B-K-2 VT NG-D-S3 SHUBBER MECHANICAL' STAIN. STEEL N/A N/A ~86-002-20 B-K-2 VT NG-D-54 SNUBBER MECHANICAL STAIN. STEEL N/A N/A- 86-002-19 B-K-2 VT NG-D-SS SHUBBER MECHANICAL STAIN. STEEL N/A N/A 86-002-147 t l

! B-K-2 VT NG-D-S6 ' SNUBBER MECHANICAL STAIN. STEEL N/A .N/A 86-002-115-

)

B-K-2 VT NG-D-S7 SNUBBER MECHANICAL STAIN. STEEL N/A N/A 86-002-116

, B-K-2 VT NG-E-H4 HANGER VARIABLE STAIN. STEEL N/A- .N/A 86-002-117 i SPRING COUNTERPOISE

~

- m

~ ~ - -- -.- - .. - -. - --- . - _ - - ~ -

11 .

t

'i ~

NIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 29 0F 47 JERSEY CENTRAL P0HER AND LIGHT COMPANY -

1. DUNER: MADISON AVENUE AT PUNCHB0HL ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK HUCLEAR GEllERATING STATION
2. PLANT: DN U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UNIT OYSTER CREEK NUCLEAR GENERATING STATION
4. ONNER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE -

S. COMMERICAL SERVICE DATE 12/23/69

6. NATIONAL BOARD NUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM . SECT.XI EXAM COMPONENT COMPONENT MATERIAL COMPONENT' ' COMPONENT INSPECTION N N BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA SHEET M-l MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM*MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMM j REACTOR RECIRCULATION -l l.

l B-K-2 VT NG-E-H5 HANGER VARIABLE STAIN. STEEL N/A N/A- 86-002-118 SPRING COUNTERPOISE I

B-K-2 VT NG-E-H6 HANGER VARIABLE STAIN. STEEL N/A N/A 86-002-119 SPRING COUNTERPOISE ,

B-K-2 VT HG-E-H7 HANGER VARIABLE STAIN. STEEL N/A N/A 86-002-120- -

SPRING COUNTERPOISE  !

B-K-2 VT NG-E-S3 SNUBBER MECHANICAL STAIN. STEEL N/A N/A 86-002-18 l

B-K-2 VT NG-E-S4 SNUBBER MECHANICAL STAIN. STEEL N/A N/A 002-17 L B-K-2 VT NG-E-S5 SNUBBER MECHANICAL STAIN. STEEL N/A N/A 86-002-145 B-K-2 VT .NG-E-S6 SNUBBER HECHANICAL STAIN. STEEL N/A- N/A 86-002-112 B-K-2 VT NG-E-S7 SNUBBER MECHANICAL STAIN. STEEL N/A N/A 86-002-113 LIQUID POISON-B-K-2 VT HP-2-H4 HANGER VARIABLE STAIN. STEEL N/A N/A. 86-002-78' SPRING l

l

~

l l

l

11 NIS-1 OHt1ERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 30 0F 47 JERSEY CEt4 TRAL P0HER AND LIGHT C0t1PANY

1. CHt4ER: HADISDN AVEfJUE AT PUtlCHB0HL ROAD,t10RRIST0Hil,H.J. 07960 OYSTER CREEK I40 CLEAR GEt4ERATIllG STATI0tl
2. PLANT: Ot1 U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
5. Ut1IT OYSTER CREEK NUCLEAR GENERATIllG STATI0tl
4. OllNER CERTIFICATE OF AUTHORIZATI0t1 (IF REQUIRED) NONE
5. C0!!MERICAL SERVICE DATE 12/23/69
6. IlATIONAL BOARD HUMBER FOR UtlIT RX VESSEL 14895 f MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM O SYSTEM SECT.XI EXAM COMP 0tlEliT C0t1PONEt4T MATERIAL COMPONENT COHPONENT INSPECTION *-

0 EOUt1TRY CATEGORY METHOD ID DESCRIPTI0tl SPECIFICATION DIAMETER THICKilESS DATA SHEET .M OMMMMmMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM LIQUID POISON B-K-2 VT HP-2-H7 HANGER VARIABLE STAIN. STEEL N/A N/A 85-026-02 SPRING B-K-2 VT tlP-2-H8 hat 4GER VARIABLE STAIN. STEEL ll/A N/A 85-026-01 SPRIllG B-K-2 VT tlP-2-H9 SUPPORT C0!1STAtlT STAIll. STEEL N/A N/A 001029

, LOAD B-K-2 VT f4P-2-H10 SUPPORT C0tiSTAllT STAIN. STEEL N/A N/A 85-026-40 LOAD SHUTDOHN C00 lit!G B-K-2 VT tlU-1-H1 SUPPORT VARIABLE CARBON STEEL N/A N/A 86-002-38 SPRING HELDED B-K-2 VT llU-1-H2 SUPPORT VARIABLE CARBON STEEL N/A N/A 86-002-125 SPRIT 1G HELDED B-K-2 VT 11U-1-H5 SUPPORT VARIABLE CARBON STEEL N/A N/A 86-002-28 SPRING HELDED

== CORE SPRAY B-K-2 VT flZ-3-H2 HA!!GER VARIABLE STAIN. STEEL N/A N/A 005932 SPRING HELDED B-K-2 VT NZ-3-H4- hat 4GER VARIABLE STAIN. STEEL N/A N/A 005952 SPRING llELDED 7

. - .__. _ _ _ _ . _ . _ _ _ _ - . __.m 11 I

HIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS. PAGE 31 0F 47 JERSEY CENTRAL P0HER AND L IGHT COMPANY

1. OHNER: MADISON AVENUE AT PUNCHBOUL ROAD,MORRISTOHN,H.J. 07960 ,

OYSTER CREEK HUCLEAR GENERATING STATION

2. PLANT: OH U.S. RT.9. 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UHIT: OYSTER CREEK NUCLEAR GENERATING STATION
4. OHNER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. CollMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD HUMBER FOR, UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMX M SYSTEM SECT.XI EXAM COMPONENT COMPONENT MATERIAL COMPONENT COMPONENT INSPECTIDH M M BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKHESS DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMMMMMAMMMMMMMMMMMMMMMMMMMMMMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM CORE SPRAY B-K-2 VT NZ-3-H9 SUPPORT VARIABLE STAIN. STEEL N/A N/A 005952 SPRING HELDED B-K-2 VT NZ-3-H10 HANGER VARIABLE STAIN. STEEL N/A N/A 005952 SPRING HELDED B-K-2 VT NZ-3-S8 SNUBBER MECHANICAL STAIN. STEEL N/A N/A 86-002-71 FEEDHATER B-K-2 VT RF-2-H3 SUPPORT VARIABLE CARBON STEEL N/A N/A 86-002-22 SPRING HELDED B-K-2 VT RF-2-H4 SUPPORT VARIABLE CARBON STEEL N/A N/A 86-002-23 SPRING HELDED B-K-2 VT RF-2-H6 SUPPORT VARIABLE CARBON STEEL N/A N/A 86-002-128 SPRING HELDED B-K-2 VT RF-2-H7 SUPPORT VARIABLE CARBON STEEL N/A N/A 86-002-129 SPRING HELDED

-- B-K-2 VT RF-2-H10 SUPPORT VARIABLE CARB0H STEEL N/A N/A 86-002-09 SPRING HELDED B-K-2 VT RF-2-S1 SHUBBER MECHANICAL CARBON STEEL' N/A N/A 86-002-140-INTEGRALLY HELDED

~.

ll NIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 32 0F 47 JERSEY CENTRAL PONER AND LIGHT COMPANY

1. CHNER: MADISON AVENUE AT PUNCHB0HL ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK NUCLEAR GENERATING STATION
2. PLANT DN U.S. RT.9, 2 HILES SOUTH OF FORKED RIVER,N.J. 08751
3. UNIT: OYSTER CREEK NUCLEAR GENERATING STATIDH
4. OHNER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE S. COMMERICAL SERVICE DATE 12/23/69
6. NATI0HAL BOARD NUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXAM COMPONENT COMPONENT MATERIAL COMPONENT COMPONENT INSPECTION M' M BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM FEEDHATER B-K-2 VT RF-2-S2 SNUBBER MECHANICAL CARBON STEEL N/A N/A 86-002-25 INTEGRALLY HELDED B-K-2 VT RF-2-S3 SHUBBER f1ECHANICAL CARBON STEEL N/A N/A 86-002-24 INTEGRALLY HELDED ,

B-K-2 VT RF-2-S7 SNUBBER f1ECHANICAL CARBON STEEL N/A- II/A 86-002-26 INTEGRALLY HELDED B-K-2 VT RF-2-S8 SNUBBER MECHANICAL CARBON STEEL N/A N/A 86-002-21 INTEGRALLY HELDED REACTOR HEAD COOLING B-K-2 VT RHC-2-H2 RESTRAINT RIGID STAIN. STEEL N/A N/A 86-002-79 MAIN STEAM B-M-2 VT NR-28A VALVE BODY CARBON STEEL N/A N/A 001035 B-M-2 VT NR-28D VALVE BODY CARBON STEEL- N/A N/A 001038 B-M-2 VT HR-28G VALVE BODY CARBON STEEL N/A N/A 000900 B-M-2 VT NR-28L VALVE BODY CARBON STEEL N/A N/A 001036

"~

H

- - _~ - _. - -_. --. - _. . - . . . . . . ~

l -

l l

IIIS-1 OtitlERS DATA REPORT FOR INSERVICE IllSPECTIONS 'PAGE 33 0F.47 JERSEY CENTRAL Poller AtlD LIGHT C0t1PANY '

1. OtillEat !!ADIS0!! AVEllVE AT PUNCHB0HL ROAD,f10RRISTONN,N.J. 07960 OYSTER CREEK NUCLEAR GENERATING STATION
2. PLAT!T: ON U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UNIT: OYSTER CREEK NUCLEAR GENERATING STATI0tl
4. OHt!ER CERTIFICATE OF AUTHORIZATI0tl (IF REQUIRED) NONE
5. COMt1ERICAL SERVICE DATE 12/23'69
6. NATIONAL BOARD NUMBER FOR UNIT RX VESSEL 14895 3

DMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMmMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM-

! D SYSTEM SECT.XI EXAM C011PONENT COMPONEllT MATERIAL C0t1PONENT COMPONENT- INSPECTION .M l M BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKf4ESS DATA SHEET

  • l ' DMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMkMMMMMMMMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMXMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMYMMMMMMMM-l l MAIN STEAM ,

B-M-2 VT NR-108A VALVE BODY CARBON STEEL N/A. N/A 000822

~ - .,

B-M-2 VT ' ' NR-108C VALVE BODY CARBON STEEL N/A tt/A 001072

[

CLEANUP DEMINERALIZER c B-M-2 VT V-16-14 VALVE BODY STAIN. STEEL N/A N/A 000831 es of' REACTOR VESSEL .

B-la-1 VT B1-14-1 CLAD PATCHES IN N/A N/A '

N/A' 85425-14'#

VESSEL e!

.f u *

.j _,

B-N-1 VT B1-14-2 CLAD AREA UtlDER SIDE N/A N/A N/A 86-226-15 0F VESSEL HEAD ,

r ..

B-N-1 VT-1 B1-15 STEAM SEPARATOR N/A N/A. N/A j , w 86-226-09

.B-N-1 VT-1 B1-15-3 STEAM DRYER s 3- N/A N/A N/A .86-226-10

= . i

}

B-N-1 VT-3 B1915-4 CORE SPRAY ANNULUS N/A N/A .N/A

.86-226-03

^ 7 PIPING c ..  ; ,

g.

s, s.

._ _ _ . __..__m. _ _ _ _ _ _ . . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ . _ _ _ _ . _ _ _ _ . _.L'

ll <- _ _

flIS-1 OL!NERS' DATA REPORT FOR INSERVICE IllSPECTIONS PAGE 34 0F 47 JERSEY CftlTRAL P0HER AND LIGHT COMPAtlY

1. 011tlER: MADISON AVEtlUE AT PUNCHB0HL ROAD.MORRISTOWN,N.J. 07960 OYSTER CREEK tluCLEAR GEllERATIllG STATI0tl

- 2. PLAllT Oil U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731

3. UNITS OYSTER CREEK NUCLEAR GEllERATING STATI0tl
4. OlitlER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. C0t4MERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD t1 UMBER FOR UNIT ~RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMM M SYSTEM SECT.XI EXAM COMPONErlT C0f1PorlENT MATERIAL COMPONEllT COMP 0llENT INSPECTION M M BOUNTRY CATEGORY METHOD ID DESCRIPTI0t1 SPECIFICATION DIAMETER THICKNESS DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMhMMMXhMMMMMMMMMMMMhMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMkMMMMMM REACTOR VESSEL B-N-2 VT-3 B1-16-1 LOLLER CORE PLATE N/A N/A N/A 86-226-11 HOLD D0ll!I BOLTS AND LIFTING LUGS B-fi-2 VT-1 B1-16-2 FUEL SUPPORT PIECES N/A N/A N/A 86-226-08 137 (4 BUllDLE) 12 (SINGLE BUllDLE)

B-N-2 VT-1 B1-16-4 CORE SPRAY SPARGER N/A N/A N/A 86-226-02 B-N-2 VT-1 B1-16-5 FEEDHATER SPARGER N/A N/A N/A 86-226-06 B-N-2 VT-1 B1-16-6 FEEDHATER SPARGER N/A N/A N/A 86-226-06 CENTER BRACKET.

B-N-2 VT-1 B1-16-7 FEEDHATER SPARGER N/A N/A N/A 86-226-06 EllD BRACKET B-N-2 VT-3 'B1-16-8 SHROUD MATING- N/A N/A N/A 86-226-07 SURFACE B-N-2 VT B1-16 STEAM DRYER' BRACKETS N/A N/A N/A '86-226-15 CONTAINNENT SPRAY C-C MT 1-2-SPT-B ItJTEGRALLY HELDED CARBON STEEL N/A N/A 006764 SUPPORT.ON C0t1TAlti-MENT SPRAY HX 1-2

'~

11 __

NIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 35 0F 47 JERSEY CENTRAL P0HER AND LIGHT COMPANY

1. CHHER: MADISON AVENUE AT PUNCHB0HL ROAD,MORRISTOHN,N.J. 07960
' OYSTER CREEK NUCLEAR GENERATING STATION

. 2. PLANT: OH U.S. RT.9. 2 HILES SOUTH OF FORKED RIVER,N.J. 08731 -

' ~

3. UNITS OYSTER CREEK NUCLEAR GENERATING STATIDH '
4. OUMER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIDHAL BOARD NUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMkMMMMM.

M. SYSTEM SECT.XI EXAM COMPONENT CGMP 0HENT MATERIAL COMPONENT COMPONENT INSPECTION. M M BOUNTRY CATEGORY METHOD- ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS' . DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMWMMMMMMa'MMMMMMMMMMMMM m

~

CONIAIHMENT SPRAY <

u --n v01- C-C MT 1-2-SPT-C INTEGRALLY HELDED CARBON STEEL- N/A N/A 086765 SUPPORT,0N CCHTAIN- - "

MENT SPRAY HX 1-2 ,

C-C MT 1-2-SPT-D INTEGRALLY HELDED . CARBON STEEL N/A. N/A 006766

, SUPPORT,0N CONTAIN-MENT SPRAY HX 1-2 ISOLATION CONDENSER

.C-E-1 PT NE-2-S21 SHUB5ER HYDRAULIC STAIN. STEEL N/A N/A 007025 INTEGRALLY.HELDED PRE-SERVICE EXAM CONTAINMENT SPRAY _

C-E-1 PT- NQ-2-H26 ~ SUPPORT CONSTANT CARBON STEEL N/A N/A- 86-003-01 LOAD HELDED CORE SPRAY C-E-1 PT NZ-1-H7 SUPPGRf CONSTANT CARBON: STEEL N/A N/A- >86-003-05

' LOAD HELDED , c' '

C-E-1 PT NZ-2-H6' HANGER. CONSTANT LOAD CARBON: STEEL N/A [~N/A 007558

'HELDED ,

== C-E-1 HT NZ-2-H22 HANGER VARIABLE CARBON STEEL N/A. N/A 86-003-02 SPRING- -

C-E-1 PT NZ-2-H45- HANGER VARIABLE. . CARBON STEEL N/A N/A '007631

-SPRING HELDED 7

- _ . . _ _ .m m__ . - -. _ ___mm . _ _ . - _ _ _ .m . . . .- m ,. -

4 e

l 11 1

1 NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 36' ~0F 47 JERSEY CENTRAL P0HER AND LIGHT COMPANY

1. CHNER MADISON AVENUE AT PUNCHB0HL ROAD,MORRISTOHN,N.J. 07960 '

OYSTLR CREEK NUCLEAR GENERATING STATION

2. PLANT OH U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UNIT: OYSTER CREEK NUCLEAR GENERATING STATION
4. OHNER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE. *
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD NUMBER FOR UNIT RX. VESSEL 14895 DMMMMMMMMMMMMMMMMMMMhMMhMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M . SYSTEM SECT.XI EXAM' COMPONENT COMPONENT MATERIAL COMPONENT COMPONENT INSPECTION 'M u BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA SHEET.M

.MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM CORE SPRAY C-E-1 MT NZ-2-S4 SNUBBER HYDRAULIC CARBON STEEL N/A N/A 006045 INTEGRALLY HELDED PRE-SERVICE EXAM C-E-1 MT NZ-2-S9 SHUBBER HYDRAULIC CARBON STEEL 10.00 0.365 004430 :I INTEGRALLY HELDED PRE-SERVICE EXAM C-E-1 PT- NZ-2-S15 SNUBBER HYDRAULIC CARBON STEEL N/A . N/A 005831 INTEGRALLY HELDED PRE-SERVICE EXAM ISOLATION CONDENSER C-E-2 .VT NE-1-H1 HANGER VARIABLE ' STAIN STEEL N/A. N/A 86-002-200 SPRING C-E-2 VT NE-1-H5 HANGER VARIABLE STAIN. STEEL N/A N/A J86-002-73' SPRING -

C-E-2 VT HE-1-H6 HANGER. VARIABLE . STAIN. STEEL N/A , N/A 86-002-95'

! SPRING 1

l C-E-2 VT NE-1-H10 HANGER VARIABLE STAIN. STEEL 'N/A N/A 86-002 l SPRING I

l -- C-E-2 VT- NE-1-S3 _ SNUBBER HYDRAULIC. ' STAIN. STEEL N/A N/A 86-002-110 l

l

C-E-2 VT NE-1-53A SNUBBER HYDRAULIC STAIN. STEEL N/A. N/A- 86-002-81.

7 l

11 NIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 37 0F 47 JERSEY CENTRAL P0HER AND LIGHT COMPANY

1. OHNER: NADISON AVENUE AT PUNCHB0HL ROAD,MORRISTONN,N.J. 07960 OYSTER CREEK NUCLEAR GEtlERATING STATION
2. PLANT: Dil U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UNIT: OYSTER CREEK NUCLEAR GENERATING STATION
4. OHNER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD NUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXAM COMPONENT COMPONENT MATERIAL COMPONENT COMPONENT INSPECTION M M BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM ISOLATION CONDENSER C-E-2 VT NE-1-S4 SNUBBER HYDRAULIC STAIN. STEEL N/A N/A 86-002-75 C-E-2 VT NE-1-SS SHUBBER HYDRAULIC STAIN. STEEL N/A N/A 86-002-74 C-E-2 VT NE-1-S12 SNUBBER HYDRAULIC STAIN. STEEL N/A N/A 86-002-82 C-E-2 VT HE-2-H11 HANGER VARIABLE STAIN. STEEL N/A N/A 86-002-98 SPRING C-E-2 VT NE-2-S8 SHUBBER HYDRAULIC STAIN. STEEL N/A N/A 86-002-96 C-E-2 VT NE-2-S10 SNUBBER HYDRAULIC STAIN. STEEL N/A N/A 86-002-132 C-E-2 VI NE-2-S21 SNUBBER HYDRAULIC STAIN. STEEL N/A N/A 86-324-02 INIEGRALLY HELDED PRE-SERVICE EXAM CONTAINMENT SPRAY'

== C-E-2 VT NQ-1-H1 SUPPORT CONSTANT CARBON STEEL N/A N/A 86-002-83 LOAD C-E-2 VT HQ-1-H3 SUPPORT CONSTANT CARBON STEEL N/A N/A 86-002-12 LOAD 7

.1

Il f4IS-1 OHilERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 38 0F 47 JERSEY CENTRAL PONER AND LIGHT COMPANY

1. OHilER: MADIS0li AVE!1UE AT PUNCHBOUL ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK HUCLEAR GEllERATIt4G STATION
2. PLAtlT Ott U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UllIT : OYSTER CREEK NUCLEAR GEt1ERATING STATION
4. O!!NER CLRTIFICATE OF AUTHORIZATI0fl (IF REQUIRED) NONE
5. COMMcRICAL SERVICE DATE 12/23/69
6. IIATIO!1AL BOARD NUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXAM COMPONEllT COMP 0tlENT MATERIAL COMP 0llENT COMPONENT INSPECTI0ft M M BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATI0tl DIAMETER THICKNESS DATA SHEET' M MMMXMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM.

C0tiTAlf4NEf1T SPRAY C-E-2 VT HQ-1-H4 SUPPORT C0t4STA!4T CARBON STEEL N/A N/A 86-002-14 LOAD C-E-2 VT tlQ-1-H7 SUPPORT CONSTAtlT CARBON STEEL N/A N/A 86-002-13 LDAD C-E-2 VT HQ-2-H6 SUPPORT VARIABLE CARBON STEEL N/A N/A 86-002-15 SPRIllG C-E-2 VT tlQ-2-H15 SUPPORT VARIABLE CARBON STEEL N/A N/A 86-002-11 SPRIllG C-E-2 VT tlQ-2-H19 HAtlGER VARIABLE CARBON STEEL N/A N/A 86-002-127 SPRIllG HELDED C-E-2 VT NQ-2-H25 RESTRAINT RIGID CARBON STEEL N/A N/A 85-026-07 C-E-2 VT NQ-2-H26B HAtiGER CONSTANT LOAD CARBON STEEL N/A N/A 005939 C-E-2 VT tlQ-2-H28 RESTRAINT RIGID CARBON STEEL N/A' N/A 86-002-164 C-E-2 VT tiQ-2-H29 HANGER VARIABLE CARBON STEEL N/A N/A 86-002-43 SPRIT 4G C-E-2 VT HQ-2-H31 RESTRAINT RIGID CARBON STEEL N/A N/A 86-002-10 7

ll NIS-1 OWilERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 39 - 0F 47 JERSEY CEllTRAL P0HER AND LIGHT COMPANY

1. ONNER: MADISON AVENUE AT PUNCHB0llL ROAD,MORRISTOHN,N.J. 07960 OYSTER CREtK NUCLEAR GEllERATING STATION
2. PLANT: Oil U. S . RT . 9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UNIT: OYSTER CREEK HUCLEAR GENERATIllG STATION
4. OWNER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD NUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXA!1 COMPONEllT COMPONEtiT MATERIAL COHPONSd COMPONENT INSPECTION M M BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECTr TEN T.R THICKNESS DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMwwwxxxa.wiff'" .- f.. nMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM CONTAINMENT SPRAY C-E-2 VT HQ-2-H33 HANGER VARIABLE CARBON STEEL N/A N/A 005939 SPRIllG C-E-2 VT NQ-2-H35 NAtlGER VARIABLE CARBON STEEL N/A N/A 85-026-06 SPRItJG C-E-2 VT HQ-2-H46 RESTRAINT RIGID CARBON STEEL N/A N/A 005939 C-E-2 VT NQ-2-H47 HAtlGER CONSTANT LOAD CARBON STEEL N/A N/A 005939 C-E-2 VT NQ-2-H48 HANGER VARIABLE CARBON STEEL -N/A N/A 86-002-80 SPRIllG C-E-2 VT HQ-2-H50 HANGER VARIABLE CARBON STEEL N/A N/A 005939 SPRIllG C-E-2 VT HQ-2-H53 hat 4GER C0tiSTANT LOAD CARBON STEEL N/A- N/A 86-002-162 C-E-2 VT NQ-2-H55 HANGER CONSTANT LOAD CARBON STEEL N/A N/A 86-002-106 C-E-2 VT tlQ-2-H59 HANGER CONSTANT LOAD CARB0!1 STEEL N/A N/A 005939 C-E-2 VT HQ-2-H62 HANGER C0t1STANT LOAD CARBON STEEL- N/A N/A 85-026-25

~

11 flIS-1 OHNERS DATA REPORT FOR IllSERVICE INSPECTIONS PAGE 40 0F 47 JERSEY CENTRAL P0HER AND LIGHT COMPANY

1. OH!iER: MADIS0tt AVEllUE AT PutiCHB0HL ROAD,MORRIST0Hil,N.J. 07960 OYSTER CREEK tiUCLEAR GENERATIllG STATI0tl
2. PLAtlT: ON U.S. RT.9. 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UtlIT: OYSTER CREEK HUCLEAR GEt4ERATING STATI0tl
4. OHNER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) N0tlE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD tiUMBER FOR UNIT RX VESSEL 14895 DMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMXXMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM U SYSTEM SECT.XI EXAtt COMPONEllT COMP 0tlEtiT MATERIAL COMPONENT Col 1PO!!ENT INSPECTION M D BOUtiTRY CATEGORY METHOD ID DESCRIPTI0tl SPECIFICATION DIAMETER THICKNESS DATA SHEET M UMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMkhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM C0tiTAINMENT SPRAY C-E-2 VT NQ-2-H68 HANGER CollSTANT LOAD CARB0tl STEEL N/A N/A 85-026-24 C-E-2 VT fiQ-2-H70 NAl1GER CONSTAtlT LDAD CARB0tl STEEL N/A N/A 86-002-102 C-E-2 VT I'HQ-2-H72 HAtlGER C0!ISTAtlT LOAD CARB0tl STEEL N/A N/A 005939 C-E-2 VT tlQ-2-H73 HAllGER C0tiSTANT LOAD CARBON STEEL N/A N/A 005939 C-E-2 VT fiQ-2-H75 HANGER C0llSTANT LOAD CARBON STEEL N/A N/A 86-002-105 C-E-2 VT tlQ-2-S3 SiluBBER HYDRAULIC CARBON STEEL N/A N/A 86-002-41 C-E-2 VT NQ-2-54 SitUBBER HYDRAULIC CARBON STEEL N/A N/A 86-002-108 C-E-2 VT NQ-2-S8 St4UBBER HYDRAULIC CARBON STEEL n/A N/A 001036 C- E-2 VT NQ-2-S9 SilVBBER HYDRAULIC CARBON STEEL N/A N/A 001040 7

4

.b

i 11 NIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 41 0F 47 JERSEY CENTRAL P0HER AND LIGHT COMPANY

1. CHNER: MADISON AVENUE AT PUNCHBONL ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK NUCLEAR GENERATING STATION
2. PLANT: ON U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UNIT: OYSTER CREEK NUCLEAR GENERATING STATION 4 ONMER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE -
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD NUMBER FOR UNIT RX VESSEL 14895 M MM M M M M M M M MM M M M M MM M M M M M M M M M M M M M M M M M M M M M M M M MM:4 M M M M M M M M M M M M M M M M M M M M M M MM M M M M M M M M M M MM M M M M MM MMM MM M M M MM MM M M M M M M M M M M M MM M M MM MM M M M M M M M M M M M M O SYSTEM SECT.XI EXAM CONPONENT COMPONENT MATERIAL COMPONENT COMPONENT INSPECTION M M BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA 4 SHEET M OMMMMMMMMMMMMAMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM CONTAINMENT / CORE SPRAY ,

i C-E-2 VT NQZ-1-H6 SUPPORT CONSTANT CARBON STEEL N/A N/A 86-002-50 LOAD l

I

! C-E-2 VT HQZ-1-H11 SUPPORT CONSTANT CARBON STEEL- N/A N/A 86-002-54 LOAD I

C-E-2 VT HQZ-1-H11A SUPPORT CONSTANT CARBON STEEL N/A N/A 86-002-53 LOAD C-E-2 VT HQZ-1-H13A SUPPORT CONSTANT CARBON STEEL N/A N/A 86-002-51' LOAD C-E-2 VT HQZ-1-H14 SUPPORT CONSTANT CARBON STEEL N/A N/A 86-002-179 l LOAD ~

l l

i C-E-2 VT HQZ-1-S4 SHUBBER HYDRAULIC CARBON STEEL N/A N/A 86-002 l PRE-SERVICE EXAM l

C-E-2 VT HQZ-1-S11 SNUBBER HYDRAULIC CARBON STEEL N/A N/A 86-002-48 l-l l:

1 DH FLOOR & EQUIP DRAINS l -- C-E-2 VT NV-7-H1 SUPPORT VARIABLE CARBON STEEL N/A .N/A '86-002-32

! SPRING l

. CORE SPRAY C-E-2 VT. NZ-1-H1' . SUPPORT CONSTANT CARBON STEEL N/A N/A 005940 LOAD l

l 1

. ~ _ - . - _.

I l

HIS-1 O!!!!ERS DATA REPORT FOR It4 SERVICE INSPECTIONS PAGE 42 0F 47 JERSEY CEllTRAL P0HER AtID LIGHT C0t4PANY

1. OllNER: MADIS0tt AVEt4UE AT PUNCHD014L ROAD,MORRISTOHN,ti.J. 07960 OYSTER CREEK fiUCLEAR GEt4ERATIt1G STATI0tl
2. PL AtlT : Ott U.S. RT.9. 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UtilT: OYSTER CREEK I4UCLEAR GEtiERATING STATION
4. OH!iER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. C014f1ERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD I4 UMBER FOR UNIT RX VESSEL 14895 DMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM u SYSTEM SECT.XI EXAf1 CCl4P014ENT COMPot4ENT MATERIAL COMPONENT COMPONENT INSPECTION M D BOUNTRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKt4ESS DATA SHEET' M' DMMMMMMMMMMMMMMMMMMMMMMMMMMMMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM i

l CORE SPRAY C-E-2 VT IIZ-1-H3 SUPPORT CONSTANT CARBON STEEL N/A N/A 005940 LOAD C-E-2 VT tlZ-1-H5 SUPPORT CONSTANT CARBON STEEL N/A ti/A 005940 LOAD C-E-2 VT NZ-1-H6 SUPPORT CONSTANT CARBON STEEL N/A N/A 005940 LOAD C-E-2 VT NZ-1-H7 SUPPORT CONSTAt4T CARBON STEEL N/A N/A 005940 LOAD C-E-2 VT f4Z-1-H9 SUPPORT C0tiSTAtlT CARB0tl STEEL N/A N/A 86-002 LOAD C-E-2 VT NZ-1-H9A SUPPORT CONSTANT CARBON STEEL. 'N/A N/A 005940 LOAD C-E-2 VT NZ-1-H10 . SUPPORT CONSTAtiT CARBON STEEL N/A N/A 86-027-07 LOAD C-E-2 VT NZ-1-H11 SUPPORT CONSTANT CARBON STEEL N/A N/A 86-027-07 LOAD C-E-2 VT NZ-1-H13 SUPPORT CONSTAtlT CARBON STEEL N/A N/A. 86-027-07 LOAD C-E-2 VT NZ-1-H14 SUPPORT CollSTAtlT CARBON STEEL N/A N/A 005940 LOAD 7

il f4IS-1 OHf4ERS DATA REPORT FOR IfiSERVICE INSPECTIONS PAGE 43 0F 47 JERSEY CEllTRAL PONER AND LIGHT COMPAt4Y

1. OHilER: MADIS0!1 AVEllUE AT PutiCHB0HL ROAD,MORRISTOWN,N.J. 07960 OYSTER CREEK tiUCLEAR GEllERATING STATION
2. PL AtlT : DN U.S. RT.9, 2 f1ILES SOUTH OF FORKED RIVER,N.J. 08731
3. UtilT : OYSTER CREEK tiUCLEAR GENERATIliG STATI0tl
4. O!!;4ER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) N0tlE
5. COMI1ERICAL SERVICE DATE 12/23/69
6. 14ATI0t4AL BOARD HUttBER FOR UtlIT RX VESSEL 14895 UMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM u SYSTEM SECT.XI EXAM COMPONElli Cor:PONEtiT MATERIAL COMPONENT COMPO!4ENT INSPECTION M U BOUT 4TRY CATEGORY METHOD ID DESCRIPTION SPECIFICATION DIAMETER THICKNESS DATA SHEET M DMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM CORE SPRAY C-E-2 VT t12-1-H15 SUPPORT CONSTAtlT CARBON STEEL N/A N/A 86-002-42 LOAD C-E-2 VT NZ-2-H1 HAtlGER VARIABLE CARBott STEEL ti/A N/A 005940 SPRIllG C-E-2 VT tlZ-2-H3 HANGER VARIABLE CARBON STEEL ti/A 11/A 005940 SPRIf4G C-E-2 VT tlZ-2-H9 hat?GE? VARIABLE CARB0tl STEEL N/A N/A- 005940 SPRI!4G C-E-2 VT tlZ-2-H12 HAtlGER VARIABLE CARB0tl STEEL N/A N/A 005940 SPRING C-E-2 VT NZ-2-H15 HAtlGER VARIABLE CARBON STEEL N/A' N/A 005940 SPRIT 1G C-E-2 VT NZ-2-H19 HANGER CONSTAtiT LOAD CARB0tl STEEL N/A N/A 86-002-44 C-E-2 VT tlZ-2-H39 HANGER CONSTANT LOAD CARBON STEEL N/A N/A 005940 C-E-2 VT tlZ-2-H44 HANGER CollSTAtlT LOAD CARBON STEEL N/A N/A 86-002-40 C-E-2 VT NZ-2-H45 HAllGER VARIABLE CARBON STEEL- N/A N/A 005940 SPRIT 4G T

i 11 HIS-1 OHtJERS DATA REPORT FOR IllSERVICE INSPECTIONS PAGE 44 0F 47 JERSEY CENTRAL PONER AllD LIGHT COMPANY

1. OHilER: MADISON AVtt40E AT PUNCHB0HL ROAD,MORRISTOHN,ti.J. 07960 OYSTER CREEK I4UCLEAR CDIERATIllG STATI0fl
2. PLAT 4T: Oil U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08751
3. UtlIT OYSTER CREEK tlUCLEAR GEllERATING SlATI0t3
4. O!!!aER CERTIFICATE OF AUTHORIZATI0tl (IF REQUIRED) flat 4E i

S. C0itMERICAL SERVICE DATE 12/23/69 l 6. NATI0tlAL BOARD flut1BER FOR Ut4IT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXAM COMPONENT C0t1PONENT f1ATERIAL COMPONEllT COMPONENT INSPECTION M M BOUtlTRY CATEGORY 11ETHOD ID DESCRIPTI0tl SPECIFICATI0fl DIAMETER THICKilESS DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMhMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM CORE SPRAY C-E-2 VT tlZ-2-H47 HANGER VARIABLE CARB0tl STEEL N/A N/A 005940 SPRIllG C-E-2 VT NZ-2-Il58 HAriGER C0tiSTAt4T LOAD CARB0tl STEEL ti/A N/A 005940 C-E-2 VT tlZ-2-S3 SNUBBER HYDRAULIC CARBute STEEL ti/A N/A 86-002-46 C-E-2 VT NZ-2-54 StluBBER HYDRAULIC CARBON STEEL N/A N/A 86-026-35 PRE-SERVICE C-E-2 VT NZ-2-S8 SNUBBER HYDRAULIC CARBON STEEL N/A N/A 86-002-16 C-E-2 VT tJZ-2-S9 SituBBER HYDRAULIC CARBON STEEL N/A N/A 85-026-34 PRE-SERVICE EXAM C-E-2 VT NZ-2-510 StiUBBER HYDRAULIC CARBON STEEL N/A N/A 86-343-02 C-E-2 VT NZ-2-S14 SNUBBER HYDRAULIC CAR, BON STEEL N/A N/A' 85-026-19 C-E-2 VT NZ-2-S15 SilVBBER HYDRAULIC CARB0tl STEEL N/A N/A 85-026-04 PRE-SERVICE EXAM 7

i

~ _ _ . ---

. 11 HIS-1 OMilERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 45 0F 47 JERSEY CEllTRAL POWER AllD LIGHT C0t1 patly

1. OutlER: MADIS0tl AVEllUE AT PUNCHB0HL ROAD,MORRISTOHN,N.J. 07960 OYSTER CREEK HUCLEAR GEllERATIllG STATI0tl
2. PLANT: Oil U.S . RI .9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UtlIl s OYSTER CREEK tlUCLEAR GEllERATIllG STATI0tl
4. OutlER CERTIFICATE OF AUTHORIZATI0tl (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATI0tlAL BOARD flUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXAM COMPONEllT COMPONENT MATERIAL COMPONENT COMPONENT INSPECTION M M B0utlTRY CATEGORY METHOD ID DESCRIPTI0tl SPECIFICATION DIAMETER THICKNESS DATA SHEET M MMMMMMMMMMMMMMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMnKMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM DEMINERALIZED HATER C-E-2 VT HD-2-H1 HANGER CONSTAt!T LOAD B241 ALLOY N/A N/A 86-002-39 ISOLATION CONDEtlSER C-F UT NE-1-27 HELD OVERLAY REPAIR A312 SS 12.00 0.687 001688 PRE-SERVICE EXAM a

CollTAINMENT SPRAY C-G UT HQ-1-6 CIRC. PIPING HELD A106 CS 12.00 0.375 002625 C-G UT HQ-1-18 CIRC. PIPING HELD A106 CS 12.00 0.375 002834 C-G MT NQ-1-61 SUCTI0ft HEAD A106 CS N/A N/A 006770 REINFORCEMENT PRE-SERVICE EXAM C-G MT NQ-1-62R1 SUCTI0tl HEAD A106 CS N/A N/A 006770 REIt!FORCEMENT PRE-SERVICE EXAM C-G MT NQ-1-63 SUCTION HEAD A106 CS N/A N/A 007512 REIt!FORCEMENT

-- . PRE-SERVICE EXAM C-G MT NQ-1-64 -SUCTION HEAD A106 CS N/A N/A 86-108-26 REItlFORCEMENT.

PRE-SERVICE EXAM C-G UT HQ-2-32 CIRC. PIPING HELD A106 CS 14.00 0.375 002557

~

- _ _ _ ___ __.__-.__.________.___.__m.

- . - - _ . - ~ - - _ . -- . .. . . . - - - - -- ,- .. _

i H

HIS-1 OHNERS DATA REPORT FOR Il4 SERVICE INSPECTIONS PAGE 46 0F'47 4

JERSEY CEllTRAL PONER AND LIGHT COMPANY I

1. OWNER: MADISON AVENUE AT PUNCHB0HL ROAD,MORRISTOWN,N.J. 07960 OYSTER CREEK HUCLEAR GENERATING STATION
2. PLANTS ON U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731
3. UNIT: OYSTER CREEK HUCLEAR GENERATIllG STATION a 4. OHNER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. NATIONAL BOARD HUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM M SYSTEM SECT.XI EXAM COMPONENT COMP 0tlENT MATERIAL COMPONENT COMPONENT INSPECTION M M BOUNTRY CATEGORY HETHOD ID DESCRIPTION SPECIFICATI0H DIAMETER THICKHESS DATA SHEET M MMMhMMMMMMMMMMMMMMMMMMMkMMMMkMMMMMMMMMMMhMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM 4 CONTAI :::C:*T SPRAY 1

C-G UT NQ-2-35 CIRC. PIPING HELD A106 CS 14.00 0.375 002559 C-G UT NQ-2-79 CIRC. PIPING HELD A106 CS 14.00 0.375 002811 C-G UT HQ-2-98 CIRC. PIPING HELD A106 CS 14.00 0.375 002556 CONTAINMENT / CORE SPRAY C-G MT HQZ-1-60R1 SUCTION HEAD A106 CS N/A N/A 006770 REINFORCEMENT PRE-SERVICE EXAM C-G MT HQZ-1-61 SUCTION HEAD A106 CS N/A N/A 006770 REINFORCEMENT PRE-SERVICE EXAM C-G MT HQZ-1-62 SUCTION HEAD A106 CS N/A , N/A 86-108-06 REINFORCEMENT PRE-SERVICE EXAM l C-G MT HQZ-1-63 SUCTION HEAD A106 CS N/A N/A. 86-108-09

! REINFORCEMENT PRE-SERVICE EXAM

== C-G MT NQZ-1-64 SUCTION HEAD A106 CS N/A N/A 86-108-20 REINFORCEMENT PRE-SERVICE EXAM C-G MT NQZ-1-65 SUCTION HEAD A106 CS N/A N/A' 86-108-15 REINFORCEMENT PRE-SERVICE EXAM 1

_ m . _ _ _ _ - __ ._ . ___ - . _ _ m_ - - _ _ _ _ _ . _. - _ . .

ll NIS-1 OHNERS DATA REPORT FOR INSERVICE INSPECTIONS PAGE 47 'OF 47 JERSEY CENTRAL POWER AND LIGHT COMPANY

1. CHNER: MADISON AVEtlUE AT PUNCHB0HL ROAD,MORRISTOHN,N.J. 07960

> OYSTER CREEK NUCLEAR GENERATING STATI0tl l 2. PLANT: ON U.S. RT.9, 2 MILES SOUTH OF FORKED RIVER,N.J. 08731

3. UtlIT : OYSTER CREEK tluCLEAR GEllERATING STATION
4. OH!lER CERTIFICATE OF AUTHORIZATION (IF REQUIRED) NONE
5. COMMERICAL SERVICE DATE 12/23/69
6. IIATIONAL BOARD NUMBER FOR UNIT RX VESSEL 14895 MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMkMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM D SYSTEM SECT.XI EXAM COMPONENT COMPONENT MATERIAL COMPONENT COMPONENT INSPECTION N M BOUNTRY CATEGORY METHOD ID DESCRIPTI0tl SPECIFICATION DIAMETER THICKNESS DATA SHEET M UMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM l

C0tiTAI!Jf1ErlT/ CORE SPRAY C-G HT tlQZ-1-66 SUCTION HEAD A106 CS N/A N/A 86-108-26 REINFORCEMENT PRE-SERVICE EXAM C-G MT NQZ-1-67 SUCTION HEAD A106 CS N/A N/A 007511 REINFORCEMENT PRE-SERVICE EXAM CORE SPRAY C-G UT NZ-1-7 CIRC.PIPIllG HELD A106 CS 12.00 0.375 002835

'C-G UT NZ-1-17 CIRC. PIPING HELD A106 CS 12.00 0.375 002816 C-G UT NZ-1-59 CIRC. PIPING HE*.D A106 CS 12.00 0.375 002833 C-G MT NZ-1-103 SUCTION HEAD A106 CS N/A N/A 86-108-13 REIllFORCEMEr1T PRE-SERVICE EXAM C-G MT NZ-1-109 SUCTI0tl HEAD A106 CS N/A N/A 86-108-06 REItlFORCEMENT PRE-SERVICE EXAM

== C-G MT NZ-1-110 SUCTIO!1 HEAD A106 CS N/A N/A 86-108-20 REINFORCEMENT-PRE-SERVICE EXAM C-G MT NZ-1-111 SUCTI0tl HEAD A106 CS N/A' N/A 86-108-15 REINFORCEMEllT PRE-SERVICE EXAM

  • FEEDilATER C-G UT RF-2-191X CIRC. PIPING HELD A106 CS 14.00 0.769 002650

r , ,-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Jersey Central Power & Linht Co. Date Feb. 3. 1987 Name Madison Avenue & Punchbowl Rd.

Morristown. N.J. 07960 Sheet 1 of 1 Oyster Creek NucleaYd'*" Oyster Creek Nuclear

2. Plant Generating Station Unit Generatine Station US Rte. 9 2 miles schYW of Forked River. N.J. 08731 A15K-51737.01/323130 Address Repair organization P.o. No., Job No., etc. ,
3. Work Perfymed by GPU Nuclear Type Code Symbot Stamp NR.

"*** 16 Authorization No.

100 Interpace Pkwy.. Parsippany. N.J. Expiration Date 01-13-89 Address

4. Identification of System Tnnineinn Condonner
5. (a) Applicable Construction Codeherinn T 14 5 ._ Edition, tJ6 7 Addenda; N/A Code Case ,

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 74 S75

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National Repaired. Stamped Name of Name of Manufacturer Board Other Year Replaced, (Yes Component Manufacturer Serial No. No. Identification Built or Replacement or No)

NE-150-1-H N/A N/A N/A N/A N/A Repair Yes NE-151-1-HX N/A N/A N/A N/A N/A Repair Yes N-N N w. ~

~

7. Description of Work Repair support lugs for hangers NE-150-1 and NE-151-1.
8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure O Not required.

Other O Pressure psi Test Temp. 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, presided (1) s*de is 8% in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 J

r FORM NIS 2 (Back)

9. Remarks This work was performed under GPU Nuclear Repair Program.

Applicable Manufacturer's Data Fleports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair conforms to the rules of the ASME Code,Section XI. P*i'*'PC"*"'

Type Code Symbol Stamp NR Certificate of Authorizati N o. _ , Expiration Date 01-13-89 A J Signed

~ - - - - - 0 Date  !} ' f_ 19 owr r's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Ha d o d Meam BoHer W Co. og liartford, Conn. have inspected the components described in this Owner's Report during the period 03-11-85 to 12-28-86 , ,no ,,,,, ,n ,

to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or imphed, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer siell be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this invection.

Commissions NB 5478 spector's Sig ure National Board, State, Province, and Endorsements Date b!Ib $l I

19 H 2/82)

/

FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Jersey Central Power & Light Co. cate Feb. 3. 1987 '

Madison Avenue & PundifUewl road Morristown, N.J. 07960 Sheet 1 of 1 Oyster Creek NucleR**" Oyster Creek Nuclear

2. mant Generating Station unit Generatine Station US Rte 9, 2 miles sodtR*of Forked River, N.J. 08731 A15E-51753/323394 Address Repair organization P.o. No., Job No., etc.
3. Work Performed by GPU Nuclear Type Code Symbol Stamp N/A 100 Interpace Pkwy. Nanie Authorization No. N/A Parsippany, N.J. Expiration Date N/A Address
4. Identification of System Feedwater
6. (a) Applicable Construction Code ANSI B31.1 19 O Edition, NA Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 74S75
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National Repaired, Stamped Name of Name of Manufacturer Board Other Year Replaced, (Yes Component Manufacturer Serial No. No. Identification Built or Replacement or No)

RF-2-191X N/A N/A N/A N/A N/A Rennfr Nn N I

~

w

~

N x

7. Description of Work Neld.was repaired due to work on Valve V-2-11
8. Tests Conducted: Hydrostatic 0 eneumatic 0 Nominal Operating Pressure @

Other Pressure psi Test Temp. 'F NOTE: Supplemental sheets in form pf lists, sketches, or drawings may be used, provided (1) site is 8% in. x 11 in., (2) Informe.

tion in items 1 through 6 on this report is included on each sheet, and (3) nach sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E 47th St., New York, N.Y.10017

FORM NIS-2 (Back)

9. Remarks Applicable Manufacturer's Data Reports to be attached on valve V-2-11. The work was performed under GPL' Nuclear Repair / Replacement Program.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this rnpn4r conforms to the rules of the

D'* D'**"'

ASME Code,Section XI.

Type Code Symbol Stamp N/A

  1. M/A Certificate of Authorization No._ L'/A e Expiration Date

^

Signed $ , 19 _

Owner or Owr =___7_, Titte CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of.Hewje rRoy and employed by IIn r r f n rrl Rronm Rnflor TAT rn_ of Martforda_ Conn. have inspected the components described in this Owner's Report during the period 03-11-85 's 12-28-86 . ar'd state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures des:ribed in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

5 // T Commissions MR ~EA7R

~~

spectors Signpre National Board, State. Province, and Endorsements Date 32/8*87 19 (12/82)

r l

l FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Jersey Central Power & Light Co. Feb. 3, 1987 ,

Madison Avenue & Pund1W6wl Road Morristown. N.J. 07360 Sheet 1 of 1 Oyster Creek Nuclett*" Oyster Creek Nuclear.

2. ment Cencratine Station unit _ Generating Station US Rtc 9, 2 miles sofft%* of Forked River N.J. 08731 Address Repair Organization P.o. No., Job No., etc.
3. Work Performed by GPU Nuclear Type Code Symbot Stamp N/A Nanie 100 Interpace Pkwy. Authorization No. N/A Parsippany. N.J. Expiration Date N/A Address
4. Identification of System Core Spray -
5. (a) Applicable Construction Code ANRT R11.1 19 . R1 Edition, NA Addenda, MA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 74S75
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National Repaired, Stamped Name of Name of Manufacturer Board Other Year Replaced, (Yes Component Manufacturer Serial No. No, identification Built or Replacement or No)

!IZ-2-S9 CPUN N/A N/A N/A N/A Repair No RZ-2-S15 GPUN N/A N/A N/A N/A Repair No S4 CPUN N/A N/A N/A N/A Repair No

~N_

~_

7. Description ot Work Weld repair to integrally welded component support.
8. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure @

Othe, O Pressure _ psi Test Temp. 'F NOTE: Supplemental sheets in form of !ists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informs.

tion in items 1 through 6 on this report in included on each sheet, and (3) each sheet is numbered and the number of sheets is I recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E.47th St., New York, N.Y.10017 I

t_ J

FORM NIS 2 (Back)

9. Remarks _ NOld_ICpairS _Qf_COMPOUCrl_Suppnrrn en rho pinino nrcSSurn Applicab.4 Manuf acturer's Data Reports to be attached

_ boundary _wcrc_ performed !n nconrdnnen virh chn c.PTf Nyclogr'c Rnpair/ Replacement _Eragrar:

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report &re correct and this conforms to the rules of the repair or replacement ASME Code,Section XI.

Type Code Symbol Stamp N/A Cert >ficate of Authorizatip No. N/A Expiration Date M/A l

^

S egoed _ _ _ Date _ 19 Ov y- -

er's Designee, Title CERTIFICATE OF INSERVICE INSPECTION l the undersigned, holding a vahd commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of _New_ Jersey and employed byIIn r r f nrd Rennm Rn11ne TET (M of

.llartford e_ Cn- have inspected the components described in this Owner's Report during the period 03-11-R$ to 12-28m86 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signmg this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property riamage or a loss of any kind arising from or connected with this inspection.

I M/V octor's Sionplure commission, NB-5478 National Board, State, Province, and Endorsements l

l Date -_T - L8 ' A 7 to l 1

I (12/82)

I l

l 1

i

FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. o ner Jersey Central Power & Light Co. g,,,

Feb. 3, 1987 -

Madison Avenue & Punc N wl Road 1 of I Morristown,-lLL_079p0 #

Sheet Oyster Creek Nuc17ar Oyster Creek Nuclear i

2. Plant Generatine Station Unit Generatinst Station '

US Rte. 9, 2 miles sod'ffi of Forked River. NJ,_QSZ31 A15K-5173LQl/328130 Address Repair Organization P.O. No., Job No., etc.

3. Work Performed byCPU Nuclear Type Code Symbol stamp N/A

'"' N/A Authorization No.

100 Interpace Pkwyu _Earsippany. N.J. Expiration Date N/A Ad dress

4. Identification of System Corg_ Spray
5. (a) Applicable Construction Code ANTS MI 1 19 83 Edition, NA Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 74 S75
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National Repaired, Stamped Name of Name of Mar.ufacturer Board Other Year Rep l aced, (Yes Component Manufacturer Serial No. N o. Identification Built or Replacement or No)

NZ-3-II7 N/A N/A N/A N/A N/A Repair No N

N

~

m N N.

7. Description of Work Pipe saddle attachment
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operatin<J Pressure O not required Other Pressure psi Test Temp. 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E.47th St., New York, N.Y.10017

\

4

FORM NIS 2 (Back)

9. Remarks This work was performed in accordance with the CPU Nuclear Applicable Manufacturer's Data Reports to be attached Repair /Re. placement Program.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair con,,,,, ,o t ne ,,,e, o, ,n, ASME Code,Section XI. ''''P'**"'

Type Code Symtml Stamp N/A Certificate of Authorizatir hNo,_,N/A g,pir, tion o,t, N/A

"[

Signed ~ diner ~

Date 19 vner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION f, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State o, p,oy,nc, o, New Jerse7 and employed by llartford Steam Boiler I&I Co. og llartford, Conn. have inspected the components described in this Owner's Report during the period 03-11-85 to__12-28-86 . nd state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

NB-5478 4

or a signaty/o in National Board, State Province, and Endorsements Date M/8d2._.19 (12/82)

I

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

,, 3 ,,, Jersey Central Power & Light Co. g,,,

Feb. 3, 1987 -

Madison Avenue & Punc To*wl Rd.

Morristown. N.J. 07.960 Sheet I of 1 Oyster Creek NucledY#tMnerating Oyster Creek Nuclear

2. Plant Station Unit Generatine Station US Rte. 9, 2 miles so"tf01 of Forked River. N.J. Q1731 A15C-1n265 /407765 Address Repair Oreenization P.O. No., Job No., etc.
3. Work Performed by CPU Nucienr Type Code Symbol Stamp N/A Name Authorization No. N/A 100 Interpace Pkwv. Paralppany. NJ. Expiration Date N/A Address
4. Identification of System Cnntninmone Rnrnv
5. (a) Applicable Construction Code _ ANSI B31.119 83 EditiM/A Addenda; N/A Code Can (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 74 S75
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National Repaired, Stamped Name of Name of Manufacturer Board Other Year Replaced, (Yes Component Manufacturer Serial No. N o, Identification Built or Replacement or No)

See item

, N/A N/A N/A N/A N/A Repair No N

N w ^

7. Description ot work _Added nozzle reinforcinst saddles. Weld numbers NQ-1-61. NO-1-62R1, i NQ-1-63 and NQ-1-64
8. Tests Conducted: Hydrostatic 0 Pneumatle Nominal Operating Pressure N ATM Other O Pressure - pil Test Temp. 'F NOTE: Supplemental sheets in form of lists, sketches, of drawings may be used, provided (1) size is 8% in, x 11 in., (2) infortna.

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N Y.10017 1

1

I l

I FORM NIS-2 (Back) 1 l

9. Remark, _ This work was for adding reinforcing saddles for attached piping on  !

Applicable Manufacturer's Data Reports to be attached the containment _s_ pray header piping. This work was performed under the l l

1 GPUN Rep _ air / Replacement Program.

l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair conforms to the rules of the ASME Code, Section Xt. D*i' "**''""'

l Type Code Symbol stamp N/A l

Certificate of Authoritatio No. _ , _ _U/A Expiration Date N/A Signed ___ .

O*r re s Designee, Title

]_ _ Date 19

(

CERTIFICATE OF INSERVICE INSPECTION i, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of New Jersey _

_ and empioved by llartford Steam Boiler I&I Co. og

_ Ilar t f o rd s Conn. have inspected the components described in this Owner's Report during the period 03-11-85 to 12-28-86 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any Warranty, expressed or implied, concerning the i examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall tut liable in any manner for any personal injury or property damage or a foss of any kind arising from or connected with this inspection.

_ Commissions NB-5478 i spo tor's SignMure National Board, State, Province, and Endorsements l

Date d18-87 / 19 (12/82)

I l

FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Jersey Central Power & Linht Co.

cate Feb 3, 1987 Name Madison Avenue & Punchbowl Rd. I Morristown. N.J. 07940 Sheet of 1 Oyster Creek $#iT*ar u c Oyster Creek Nuclear

2. PlaniConorntine Station Unit Generatine Station US Rte 9: 2 miles souYN"*of Forked River. N.J. 08 D1 Address A15C-10265/402265 Repair organisation P.O. No., Job No., etc.
3. Work Performed by CPU Niic1 onr Type Code Symbol Stamp N/A Name N/A Authorization No.

100 Tntornnco Pkt.rv. . PnrRippany N_.1. Expiration Date N/A

" Address

4. Identification of System Pnro Rnrny
5. (a) Applicable Construction CodeASMT n31 1 19X Edition, N/A Addenda, M/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 7A R75
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National Repaired, Stamped Name of Name of Manufacturer Board Other Year Replaced, (Yes Component Manufacturer Serial No. No. Identification Built or Replacement or No)

See below Item 7 N/A N/A N/A N/A N/A Repair No

7. Description of work Added nozzle reinforcing saddles. Weld numbers NZ-1-108 through NZ-1-111.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Q ATM Other O Pressure psi Test Temp. 'F NOTE: Supplemental sheets in form of lists, sketches, of drawings may be used, provided (1) site is 8% in. x 11 In., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

FORM NIS 2 (Back)

9. nemaru, This work was for adding reinforcing saddles for attached piping on the Applicable Manufacturer's Data Reports to be attached containment Spray Header Piping. This work was performed under the CPUN Repair / Replacement Proy, ram.

CERTIFICATE OF COMPLIANCE We celify that the statements made in the report are correct and thi[ODOII conforms to the rules of the ASME Code,Section XI. P' P'**"*

Type Code Symbol Stamp N/A Certificate of Authoritation 3 I/b Expiration Date N/A Signed " ' Date 19 owner esigne's. Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors ac.d the State or Province o, New Jersey and empioved by llartford Steam Boiler I&I Co. og llartford, Conn. have inspected the components described in this Owner's Report during the period 03-11-85 to 12-28-86 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By sigmng this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection, j/ NB-5478

_. Comm,ssions i

I ri jector's Signatut National Board, State, Province, and Endorsements Date Mb87 19 (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I

i

1. Owner Jersey Central Power & Light Co. o te Feb. 3. 1987 -

Madison Avenue & PunchtfMT Rd.

Morristown, N.J. 07960 Sheet 1 of 1 Oyster Creek Nuc^fEa*Y Generating Oyster Creek

2. Plant Rt nt-i nn UnitGenerating Station US Rte. 9, 2 miles soutW'6f Forked River. N.J. 08731 A15B-51776.2/323344 Address Repair Organization P.O. No., Job No., etc.
3. Work Performed by GPU Nuclear Type Code Symbot Stamp NR Name 16 Authorization No.

100 Interpace Pkwv.. Parsippany. N.J. Expiration Date 13-89 Address

4. Identification of System Isolation Condenser
5. (a) Applicable Construction Code Sect. I 19 62 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 74S75
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code Repaired, Stamped National Name of Name of Manufacturer Board Other Year Replaced, (Yes Component Manufacturer Serial No. No. Identification Built or Replacement or No)

Ber NF-2-M1 ROtUgen-t n n r OS~b EN 6 '14-R N/A 5 N/A N/A Repnir Ynn

~

N w

N N x

7. Description ot Work Addi tinnnt unt d to ovinting support.
8. Tests Conducted:
  • Hydrostatic 0 Pneumatic Nominal Operating Pressure *Not required Other O Preisure psi Test Tema. 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N f.10017

\\

FORM NIS-2 (Back)

9. Remarks _ThisJork_was_ performed under the GPU Nuclear Repair Program.

Applicable Manufacturer's Data Reports to be attached l

l 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reDair conforms to the rules of the repair or replaconient ASME Code, Section Xl.

Type Code Symbol Stamp NR l Certificate of Authorization No._ d6._ _ Expiration Date 01-13-89 Signed . _k Date 19 I

owner nr snee. Title l

CERTIFICATE OF INSERVICE INSPECTION t, the undersigned, holding a valid commission issued by the National Board of Boder and Pressure Vessel Inspectors and the State or Province of 3CWJCISeV and employed byllartford Steam Eoilgr I&I Co. of llartford, Conn. have inspected the components described in this Owner's Report during the period- .03-11-85 to 12-28-R6 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the ,

l examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for ar y personal injury or property damage or a foss of any kind arising from or connected with this inspection, t tIIP Commissions NR-547R I estor's S6gpure National Board, State, Prcvince, and Endorsements Date [M 19 (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Ccde Section XI Jersey Central Power & Light Co. g Feb. 3, 1987 ,

Madison Avenue & Pundff68wl Road Morristown. N.J. 07160 Sheet 1 of. ._1 Oyster Creek Nucledfd'*** Oyster Creek Nuclear

2. Plant Conornrine Station UnitGeneratine Station i l

US Rte 9, 2 miles souTfi*of -s Eorked River. N.J. 08731 Address Repsir Organization P.O. No., Job No., etc.

3. Work Performed by CPU Nuclear Type Code Symbol Stamp N/A 100 Interpace Pkwy. Authorization No. N /A Parsippany. N.J. Expiration Date N/A Address
4. ddentification of System Containment / Core Sorav
5. (a) Applicable Construction Code ANSI B31. I 19 83 _ Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 74S 75
6. fdentification of Components Repaired or Replaced and Replacement Components ASME Code National Repaired, Stamped Nacne of Name of Manufacturer Board Other Year Replaced, (Yes Component Manufacturer Serial No. N o. Identification Built or Replacement or No)

See below Trom #7 N/A N/A N/A N/A N/A Renair No N

s m

N N N. _

7. Description of Work e M&Mg saMes, WM nmbs @-MM, @-M through NQZ-1-67 l
8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure @ ATM Other Pressure psi Test Temp. 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. l l

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 i

3 1

a FORM NIS 2 (Back) 9, g ,,,,, , ,

This work was for adding reinforcing saddles for attached piping Applicable Manufacturer's Data Reports to be attached on the containment spray header piping. This work was performed under the GPUN Repair / Replacement Program.

CERTIFICATE OF COMPLI ANCE l We certify that the state nents made in the report are correct and thie_Tepeir conf orms to the rules of the repair or rentac. ament ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Auth rization No. Expiration Date Signed -- M

_j_ Date _19 owne DEgnee. Title CERTIFICATE OF INSERVICE WSPECTION t, the undersig d.ho ing a valid commission issued by the atio se inspectors and the State i Bo rd h of Boilergnd am o M P essur or Pro 'oce f OY and employed by ad M o. O, ha in this Owner's Report during the perMd-- 03-11-85 to E

12-N i ected the components <!escribed

, and state that to t'te best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described $n this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, exprersed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither t'.o inspector nor his empleyer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with tnis inspection.

F Commissions NB 5478 edor's SignagLre National Board, State, Province, and E r.dersements Date.

  • Id7 O (12/82)

_ _ - _ - - ~ _ - - _ _ . - - _ - - - - . _ - - - - - - - -

l FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Jersey Central Power & Light Co. g,,,Feb. 3, 1987 <

Madison Ave. & PunchboST*Rd.

Morristown. N.J. 07960 Sheet 1 of 1 1 Address

2. Plant Ovster Creek Nucient Generatine Station Unit Oyster Crook Nitclonr Conorneing Station US Rte'9, 2 miles sodtif*of Forked River. N.J. 08731 A19D-101R7 /A071R 7 Address Repair orgarilration P.O. No., Job No., etc.
3. Work Performed by CPU Ntic1onr Type Code Symbol Stamp NR Authorization No. 16 100 Tnterpace Pkuv. Parsippany. N..T. Expiration Date D1-13-RQ Address
4. Identification of System Ronoent Unnel Vonr
5. (a) Applicable Construction Code Roc t i nn T 19 69 Edition, M/A 127gN)M1272N, 2 1273N Addenda. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 74S75
6. Identification of Components Repaired or Replaced and Replacement Components l

l ASME Code National Repaired, Stamped Name of Name of Manufacturer Board Other Year Replaced, (Yes Component Manufacturer Serial No. Identification or Replacement or No)

N o. Built Combustion See Item Reactor Vessel Engineering 64202 14895 NJ70-226 1966 -7d Yes N

N

~

m

~

N

7. Description of Work Reactor Head Vent Piping Modification. New installation weld numbers MV-002 through MV-007 and MV-012.
8. Tests Conducted: Hydrostatic W Pneumatic Nominal Operating Pressure Other Pressure 1040 psi Test Temp. *F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

j (12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E,47th St., New York, N.Y.10017 1

e

~

FORM NIS 2 (Back)

9. Remarks This work was a modification for the Reactor Head Vent System. This Applicable Manuf acturer's Data Reports to be attached work was p_erformed_und_er the CPU Nuclear Repair Program.

CERTIFICATE OF COMPLIANCE modification We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI. '*P

  • i' P'*****"'

Type Code Symbol Stamp NR Certificate of Authorizatio N o. )6 Expiration Date 01-13-89 Signed om er or v .

r s Designee, Title

_ Date l ___._ ., 19 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State ur Province of New Jersey and e,r.pioy,d ey Hartford Steam Boiler I&I Co. of have inspected the components described in this Owner's Report during the period 03-11-85 to 12-18-86 _ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NR 5478 insp4uor's SignatureU National Board, State, Province, and Endorsements Date / ~ 19 (12/82)

E-FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Jersey Central Power & Light Co. o,,,Feb. 3, 1987 -

Madison Avenue & U *I"n*c h b o w l R o a d Morristown, N.J. 07960 Sheet 1 of 2 Oyster C r e e k ^dd'*" Oyster Creek

2. PlantNu c l e a r Ge n e r a t in n Station Unit Nucient Generating Station Narne US Rte 9, 2 miles south of Forked River. NJ 08731 040878 Address Repair organization P.o. No., Job No., etc.
3. Work Performed by Genera 1 E1ectrie Company Type Code Symbot Stamp NR 1000 First Ave. Narne Authorization No. 42 King of Purssia Pa. 19406 Expiration oate May 27, 1989 Address
4. Identification of System Reac tor Recirculation, Isolation Condenser Section I 1965 W67
5. (a) Applicable Construction Code Sect. XI 19 83 Edition, Win t e r Addenda, 1980 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National Repaired, Stamped Namecf Name of Manufacturer Board Other Year Replaced, (Yes Comoonent Manufacturer Serial No. No. Identification Built or Replacement or No)

Piping Weld General Reactor NG-C-17R1 Electric Recir Repair Yes Piping Weld General Reactor NG-C-23R1 Electric Recir Repair Yes Piping Weld General Isolation NE-1-27R1 Electric Condenser Repair Yes

7. Description of Work Welded overlay repairs.
8. Tests Conducted: Hydrostatic @ Pneumatic 0 Nominal Operating Pressure Other Pressure 10 4 0 psi Test Temp. +P NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in itams 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E.47th St., New York, N.Y.10017

.l

2 of 2 FORM NIS 2 (Back)

9. Remarks _ Weld ove rlay repairs were made as a result of detecting Applicable Manufacturer's Data Reports to be attached indications that were characteristic of intergranular stress corrosion cracking.

CERTIFICATE OF COMPLI ANCE We certify that the statements made in ne report are correct and this YeDair conforms to the rules of the repair or replacernent ASME Code,Section XI.

Type Code Symbol Stamp NR Certificate of Authoriz ion No g42 Expiration Date May 27. 1989 Signed O

wner's Designee, Title

_/N - Date 19 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by 11a r t f o r d Steam Boi1er I&I Co. of iia r t f o r d . Conn. have inspected the compone..., described in this Owner's Report during the period O 'l- 1 1 - R 5 to 12-2R-R6 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection, gh .

Comm.issions NB-5478 in ector's signaturf National Board, State, Province, and Endorsements Date ~b 19 (12/82) i