TOLEDO

%s EDISON JOE WILUAMS. JR Docket No. 50-346 (419]249-2300 l*3*** * '

License No. NPF-3 Serial No. 1258 April 10, 1986 Mr. Harold Denton, Director Office of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Washington, D. C.

20555

Dear Mr. Denton:

Attached is Toledo Edison's response to John F. Stolz's letter to Joe Williams, Jr. " Request for Additional Information: Motor Operated Valves" dated March 11, 1986, Log No. 1926. The information included in this submittal resolves all open questions regarding the Davis-Besse program for maintenance and testing of nuclear safety-related motor operated valves.

This response will be included in Revision 8 of the Davis-Besse Course of Action (COA).

Yours very truly, M

JW:RRS:plf Attachment cc: DB-1 NRC Resident Inspector 8604150344 860410 PDR ADOCK 05000346 P

PDR-l THE TOLEOO EDISON COMPANY EDISON PLAZA 300 MADISON AVENUE TOLEDO, OHIO 43052

r-

, 1

. 1 i

t l-l TOLEDO EDISON'S RESPONSE 1

TO

" REQUEST FOR ADDITIONAL INFORMATION DAVIS-BESSE DOCKET No. 50-346 DAVIS-BESSE ACTION PLAN #12 - AUXILIARY FEEDWATER SYSTEM ISOLATION VALVES AF-599 AND AF-608-AND OTHER SAFETY RELATED MOTOR OPERATED VALVES AND DAVIS-BESSE ACTION PLAN #27 - MAIN STEAM SYSTEM VALVE MS-106" t

i l

i I

. 3 s.

y 1-,-,y.~

-,-v,,,

,.,. -,,. ~ r ew,,r w

-w, 40---

vvv, r,-

v-,-.wr

,ve---e

+-w--


v-4.w--w

-fr=---em,+-- < - + -

Question No. 1.

Confirm that the most limiting opening and closing requirement (pressure l

. differential and/or flow rate) for all nuclear safety related motor operated valves will be identified before restart and will meet present design requirements.

Response to Question No. 1.

i l

Toledo Edison has identified the most limiting opening and closing require-ments (pressure differential and/or flow rate)-for all torque seated.

i nuclear safety related (NSR) motor operated valves (MOVs), attached. This includes all valves considered for confirmatory testing against their most

(

limiting operational requirement.

The remaining most limiting opening and closing requirements for position seated MOVs (i.e. butterfly, dampers, etc.) is still in the preparation and review process.

This process is being performed in accordance with Nuclear Engineering Procedure NEP-092, attached. The summary list of limiting requirements developed using methodology in NEP-092, for all NSR-MOVs, will be completed prior to restart.

I l

i l

l

1 Sheet 1 of 3 LIMITING D/P OF TORQUE SEATED VALVES (Includes All Limitorque Operated Nuclear Safety Related MOV's)

VALVE VALVE LIMITING CATEGORY VALVE NO.

TYPE SIZE D/P 8

Mull GB 2.5 150 11 CS1530 GB 8.0 220 11 CS1531 GB 8.0 220 15 AF3869 GT 6.0 1050 15 AF3870 GT 6.0 1050 15 AF3871 GT 6.0 1050 15 AF3872 GT 6.0 1050 15 AF360 GT 6.0 965 i

15 AF388 GT 6.0 965 i

17 DH7A GT 14.0 50 17 DH7B GT 14.0 50 17 DH9A GT 14.0 30 17 DH9B GT 14.0 30 i

18 FW779 GT 18.0 1100 18 FW780 GT 18.0 1100 19 DH2736 GB 1.5 190 19 HP31 GB 1.5 1909 i

19 HP32 GB 1.5 1909 21 CF2A GB 1.0 720 21 CF2B CB 1.0 720 21 CFSA GB 1.0 710 4

{

21 CFSB GB 1.0 710 21 MU59A GB 1.0 2140 21 MU59B GB 1.0 2140 21 MU59C GB 1.0 2140 l

21 MU59D GB 1.0 2140 22 CC4100 GB 1.5 60 22 CC4200 GB 1.5 60 22 CC4300 GB 1.5 60 i

22 CC4400 GB 1.5 60 22 MU4 GB 1.5 2140 23 HP2A GB 2.5 2525 1

23 HP2B GB 2.5 2525 23 HP2C GB 2.5 2525 l

23 HP2D GB 2.5 2525 23 RC2 GB 2.5 91 24 CV624 GT 0.75 45 24 CV625 GT 0.75 45 l

25 CV2000 GT 1.0 38 i

25 CV2001 GT 1.0 38 25 CV2002 GT 1.0 38 PREPARED BY k /f g d DATE t/1/d4

/

CHECKED BY DATE

~

Shest 2 of 3 l

LIMITING D/P OF TORQUE SEATED VALVES VALVE VALVE LIMITING CATEGORY VALVE NO.

TYPE SIZE D/P 25 C"2003 GT 1.0 38 25 RC200 GT 1.0 2450 25 RC239A GT 1.0 2550 25 RC239B GT 1.0 2550 25 RC240A GT.

1.0 2450 25 RC240B GT 1.0 2450 25 SW5067 GT 1.0 129 25 SW5068 GT 1.0 129 26 DH2735 GT 1.5 190 26 SW2927 GT 1.5 129 26 SW2928 GT 1.5 129 27 SW5423 GT 2.0 129 28 MUlA GT 2.5 2500 28 MU1B GT 2.5 2500 28 MU2A GT 2.5 2500 28 MU2B GT 2.5 2500 28 MU10A GT 2.5 150 28 FW10B GT 2.5 150 4

28 MU12A GT 2.5 150 28 MU12B GT 2.5 150 28 MU40 GT 2.5 65 28 RC10 GT 2.5 82 28 RC11 GT 2.5 2550 28 MU63 GT 2.5 150 4

29 CC1328 GT 3.0 90 29 CC1338 GT 3.0 90 l

29 CC1567A GT 3.0 136 29 CC1567B GT 3.0 136 29 SW5421 GT 3.0 129 1

29 SW5422 GT 3.0 129 29 SW5424 GT 3.0 129 29 SW5425 GT 3.0 129 i

30 CC1409 GT 4.0 150 3

30 CC1410 GT 4.0 150 j

30 DH63 GT 4.0 190 1

30 DH64 GT 4.0 190 30 DR2012A GT 4.0 37 30 DR2012B GT 4.0 37 30 MS603 GT 4.0 1050 30 MS611 GT 4.0 1050 30 SW1379 GT 4.0 129 30 SW1380 GT 4.0 129 30 SW1381 GT 4.0 129 31 AF599 GT 6.0

-1050 i

31 AF608 GT 6.0 1050 31 MS106 GT 6.0 1050

,i 31 MS106A GT 6.0 1050 31 MS107 GT 6.0 1050 1

i 4

__ ~

Shast 3 of 3 LIMITING D/P OF TORQUE SEATED VALVES

)

(Includes All Limitorque Operated Nuclear Safety Related MOV's) l VALVE VALVE LIMITING 1

CATEGORY VALVE NO.

TYPE SIZE D/P 31 MS107A GT 6.0 1050 4

32 DH830 GT 8.0 206 32 HD831 GT 8.0 206 33 DHIA GT 10.0 2155 34 CC5097.

GT 10.0 2155 33 DH1B GT 12.0 50 34 CC5098 GT 12.0 50 34 DHll GT 12.0 272 34 DH12 GT 12.0 272 34 DH1517 GT 12.0 298 34 DH1518 GT 12.0 298 35 CFIA GT 14.0 723 35 CF1B GT 14.0 723 36 CC2645 GT 16.0 75 36 CC2649 GT 16.0 75 37 DH2733 GT 18.0 300 37 DH2734 GT 18.0 300 37 FW601 GT 18.0 1500 37 FW612 GT 13.0 1500 38 CC5095 GT 20.0 90 38 CC5096 GT 20.0 90 i

i 1

4 1