ML20205M491

From kanterella
Jump to navigation Jump to search
Rev 5 to McGuire Nuclear Station Pump & Valve Inservice Testing,Unit 2
ML20205M491
Person / Time
Site: McGuire, Mcguire  
Issue date: 04/01/1986
From:
DUKE POWER CO.
To:
Shared Package
ML20205M486 List:
References
PROC-860401, NUDOCS 8604150284
Download: ML20205M491 (60)


Text

.-

hT O

i DUKE POWER COMPANY McGUIRE NUCLEAR STATION PUMP AND VAEVE INSERVICE TESTING UNIT 2 REVISION # 5 f$4150284860401 p

ADDCK 05000369 PDR 1;

x

~o n

A b

g Q

i m

a j

g j

System: Auxiliary Feedwater i

l u

i a

T

?.

4 4

u

=

i 3

j Valve Category j

j A

8 1

j Valve Number u

Drawina Number u

A B

C D

H M

H Remarks I

2CA-7A C

MC-2592-1.1 B-10 X

CT 10 sec. cycle time I

2CA-15A C

MC-2592-1.1 D-3 X

CT 10 sec. cycle time a

J 2CA-86A C

MC-2592-1.1 C-14 X

CT 10 sec. max. cycle tide 2CA-1168 C'

MC-2592-1.1 L-7 X

CT 10 sec. max. cycle time I

J 2CA-26 C

MC-2592-1.1 1-4 X

MT

)

2CA-27A C

MC-2592-1.1 J-5 X

CT X

60 sec. max. cycle time l

i j

5l 2CA-32B C

MC-2592-1.1 I-7 X

CT X

60 sec. max. cycle time l

l 2CA-31 C

MC-2592-1.1 I-7 X

MT j

2CA-22 C

MC-2592-1.1 I-10 X

ffT i

2CA-20A,B C

MC-2592-1.1 I-10 X

CT X

60 sec. max. cycle time i

McGUIRE - UNIT 2 11.6-5 i

l Revision 5 I

}

l l

re t

a c

w 6i d

e e

- s e

m m

6. i e

i i

v F

t t

1 e 1R y

e e

r l

l a

c c

i y

y l

s c

c i

k x

r u

a x

x A

m a

a e

m m

R m

c c

e e

e t

s s

sy 0

0 S

1 1

t y

F 5tl."4.ag:H n

R O

?.* w" :M X

X

" Ee"1lu u:H T

T T

T C

C H

H y

D ro ge C

X X

ta C

B X

X ev la A

V 2

2 4

4 1

1 1

1

." g e$a B

B C

G re b

n 1

1 1

1 u

a N

1 1

1 1

g 2

2 2

2 n

9 9

9 9

i 5

5 5

5 w

2 2

2 2

a r

C C

C C

D H

H H

H m5a C

C C

C 2

T

. N I

r

__ U e

b m

u C

C 2

5 6

N 1

6 6

6 6

e 1

1 1

1 l

l v

i l

A A _ A A

G a

C C

C C

c M

V 2

2 2

2 l

l 4

4

~...

e-(

i l

MC-2592-1.0 l

5 VALVE:

2CA-60A, 2CA-64A,B, 2CA-56A, 2CA-52A,B, 2CA-44B, 2CA-48A,B, 2CA-408, 2CA-36A,B l

CATEGORY:

B CLASS:

C FUNCTION:

Control aux. feedwater flow to S/G's 4

~

TEST REQUIREMENT:

Full stroke exercise and stroke time quarterly j

BASIS FOR RELIEF:

Valves can only be timed when aux. feed receives an

  • auto-start signal.

ALTERNATE TESTING: Valve will be full' stroke exercised quarterly and i

timed during ESF testing.

1 l

I il I

1 i

i J

8 l

t 1

McGUIRE - UNIT 2 II.6-7 j

Revision 5 a

1

9 MC-2592-1.0 5l VALVE:

2CA-61, 2CA-53, 2CA-45, 2CA-37, 2CA-65, 2CA-57, 2CA-49, l

2CA-41 CATEGORY:

C CLASS:

B FUNCTION:

Check flow from steam generators to aux, feedwater TEST REQUIREMENT:

Full stroke exercise quarterly BASIS FOR RELIEF:

Flow through these valves would unnecessarily thermal shock the S/G and feedwater piping.

5 ALTERNATE TESTING: Valves will be full stroke exercised during/after cold shutdown but prior to startup.

O 1

l l

O McGUIRE - UNIT 2 II.6-8 Revision 5

a e

4-J MC-2592-1.1 5l VALVE:

2CA-20A,B, 2CA-27A, 2CA-32B l

e i

CATEGORY:

B CLASS:

C FUNCTION:

Maintains minimum flow for Auxiliary Feedwater Pumps.

TEST REQUIREMENT:

Full stroke exercise and stroke time quarterly BASIS FOR RELIEF:

This valve automatically regulates to maintain the minimum flow through the pump by monitoring the flow on the suction of the pump. There are not sufficient manual controls on this valve to permit the desired testing.

I These valves will operate during testing of the pump and

]

their operability will be verified then.

l ALTERNATE TESTING: These valves will be full stroke exercised quarterly and stroke timed during ESF testing.

i I

a i

i l

I l

3 McGUIRE - UNIT 2 II.6-9 Revision 5 d

,j MC-2592-1.1 VALVE:

2CA-165, 2CA-166 CATEGORT:

C CLASS:

C FUNCTION:

Prevents backflow from Aux. Feedwater System to Nuclear Service Water System TEST REQUIREMElfr:

Full stroke exercise quarterly BASIS FOR RELIZF:

Flow cannot be put through these valves because this would contaminate the aux. feed system with raw water.

ALTERNATE TESTING:

At least one of these two valves will be disassembled and full stroked during each refueling outage, and both valves will have been disassembled and full stroked after 4

two consecutive refueling outages. Failure of one valve to properly full stroke during a refueling outage will result in the remaining valve being disassembled and full stroked during that outage.

O O

McGUIRE - UNIT 2 II.6-10 Revision 4

. _ _ ~

I SYSTEM:

CHEMICAL & VOLUME CONTROL SYSTEM 1

l FLOW DIAGRAMS:

MC-2554-1.1 MC-2554-1.2

)

MC-2554-1.3 l

MC-2554-2.0 MC-2554-3.0 MC-2554-3.1 i

I I

l 1

i 4

l i

l I;

.I T

l McGUIRE - UNIT 2 II.9-1 I

e

--wr

-4m-,-+-w<,w.

.,-m.,+.-we,

-- e e-ev e,w -.

.,..v-e m -r-www_

- w, e ow e --

O iystem:

Chemical and Volume Control E

O 2

a a

a N

t 0

N w

2 Valve Category d

U u

M 8

E Y

H H

Valve Number Drawing Number A

B C

I)

Remarks 5 l 2NV-94A,C B

HC-2554-1.I J-13 X

CT X

CS 10 sec. max. cycle time l

5 l 2NV-9511 B

HC-2554-1.1 11 - 1 3 X

CT X

CS 10 sec. max. cycle time l

2NV-12 B

HC-2554-1.2 F-ll X

HT 5

l 2NV-21A A

HC-2554-1.2 E-3 X

CT X

CS 60 sec. max. cycle time l

5 l 2NV-22 A

HC-2554-1.2 C-3 X

HT X

CS l

2NV-457A B

HC-2554-1.2 I-7 X

CT lsolation time $15 sec.

2NV-458A B

HC-2554-1.2 J-7 X

CT Isolation time $15 sec.

2NV-459A B

HC-2554-1.2 K-7 X

CT Isolation time $15 sec.

2NV-78 B

HC-2554-1.2 J-10 X

CT X

CS 10 sec. max. cycle time 2NV-1A A

HC-2554-1.2 C-5 X

CT X

CS 10 sec. max. cycle time 2NV-2A A

HC-2554-1.2 D-5 X

CT X

CS 10 sec. max. cycle time Revisi

l O

O 3

i System: Chemical and Volume Control a

s I

e 5"

D a

A

~%

Pg

$$ U.

I Valve Category u

4 J

B 1"

3" Valve Number Drawina Number A

B C

D H

H Remarks o

2NV-24B A.

MC-2554-1.2 D-6 X

Cr 60 sec. max. cycle time j

1 2NV-25B A

HC-2554-1.2 D-7 X

.CT 60 sec. max. cycle. time 5 l 2N,V-1013C E

HC-2554-1.3 F-12 X

CT 30 sec. max. cycle time l

{

}

J 2NV-1012C E

HC-2554-1,3 F-12 X

CT 30 sec, max, cycle time 4

I 2NV-844 E

HC-2554-1,3 F-5 X

Nr i

2NV-1007 B

HC-2554-1.3 F-13 X

HT X

CS i

f 2NV-1008 B

HC-2554-1.3 F-13 X

HT X

CS 1

l 2NV-1009 8

MC-2554-1.3 T 14 X

MT X

CS i

2NV-1010 B

HC-2554-1.3 F-14 X

NT X

CS i

1 i

McCUIRE - UNIT 2 II.9-2a l

Revision 5 l

System:

Chemical and Volume Control 0

0 a

E Y

a 4

A

~t

!?l 3

?

Valve Category 4$ $.

u j

E eE E" Valve Number Drawing Number A

B C

D H

H Remarks 2NV-842A,C B

HC-2554-1.3 F-1 X

CT 15 sec. max. cycle time 2NV-849A C B

HC-2554-1.3 F-8 X

LT 15 sec. max. cycle time CT 2NV-1002 B

HC-2554-1.3 F-10 X

X LT X

RF MT 4

2NV-141A B

HC-2554-2.0 B-8 X

CT X

CS 10 sec. max. cycle time 2NV-142B B

HC-2554-2.0 B-7 X

CT X

CS 10 sec. max. cycle tice 2NV-244A B

HC-2554-3.0 K-8 X

CT X

CS 10 sec. max. operating time 2NV-245B B

HC-2554-3.0 K-9 X

CT X

CS 10 sec. max. operating time O_ em 2 e

>>.9

v System:

Chemical and Volume Control a

E e

?

t 4

a ot ra

?

valve Catesory ag tt 4

8 Og u

Valve Number Drawing Number o

A B

C D

H MM H<

Remarks 2NV-222B B

HC-2554-3.1 1-1 X

CT X

CS 10 sec. max. cycle time l

2NV-221A B

HC-2554-3.1 11 - 1 X

CT X

CS 10 sec. max. cycle time 5l 2NV-223 B

HC-2554-3.I 1-2 X

HT X

RF l

2NV-227 B

HC-2554-3.1 E-6 X

HT 2NV-233 B

HC-2554-3.1 E-10 X

HT 5l 2NV-231 B

HC-2554-3.I F-10 X

HT X

RF l

5l 2NV-225 B

HC-2554-3.I F-5 X

HT X

RF l

l 1

McGUIRE - UNIT 2 l

II.9-4 Revision 5

MC-2554-1.I VALVE:

2NV-94A,C,2NV-95B CATEGORY:

B CLASS:

B FUNCTION:

a)

Provide containment isolation b)

Reactor coolant pump seal water discharge line.

TEST REQUIREMENT:

Cycle and time every three months.

BASIS FOR RELIEF:

Closure of one of these valves during unit operation would inhibit normal seal water flow across the reactor coolant pump number 1 seal.

This action could result in damage to the reactor coolant pump seals or the pumps themselves.

ALTERNATE TESTING:

Valves wili 'oe cycled and timed during cold shutdowns.

O

\\

l McGUIRE - UNIT 2 II.9-5

a MC-2554-1.2 VALVE:

2 NV-21A CATEGORY:

3 CLASS:

A FUNCTION:

Isolates Pressurizar Auxiliary Spray TEST REQUIREMENT:

Cycle and time every three months BASIS FOR RELIEF:

Opening this valve could result in a reactor low pressure trip ALTERNATE TESTING:

Valve will be cycled and timed during cold shutdown.

O McGUIRE - UNIT 2 II.9-6b Revision 1 New Page

O MC-2554-1.2 VALVE:

2NV-22 CATEGORY:

C l

CLASS:

A FUNCTION:

Prevents depressurizing the PZR when not using NV Aux.

Spray.

TEST REQUIREMENT:

Full stroke exercise quarterly BASIS FOR RELIEF:

Full stroking this valve could result in a reactor low presstire trip and thermal shock the aux spray nozzles to the PZR.

ALTERNATE TESTING:

Valve will be full stroked at cold shutdown.

O l

l i

i l

O McGUIRE - UNIT 2 II.9-6c Revision 5 New Page

l MC-2554-3.1 VALVE:

2NV-225, 2NV-231 CATEGORY:

C CLASS:

B FUNCTION:

Opens on flow from the Centrifugal Charging Pump (s).

TEST REQUIREMENT:

Verify proper valve movement every three months.

BASIS FOR RELIEF:

Valve cannot be full or partial stroke exercised during power operation or cold shutdown because this would result in an increase in the RCS boron inventory and could result in a plant shutdown.

Full stroke exercising during cold shutdown could result in a low temp. overpressurization of the RCS.

ALTERNATE TESTING:

Valve will be full stroked during refueling.

O 90 McGUIRE - UNIT 2 11.9-10

O MC-2554-3.1 VALVE:

2NV-223 CATEGORY.

C CLASS:

B FUNCTION:

Opens on flow alignment from FWST.

TEST REQUIREMENT:

Verify proper valve movement every three months.

BASIS FOR RELIEF:

Testing of this valve requires opening 2NV-221A or 2NV-2228. Failure of one of these valves in the open position aligns the FWST to the suction of the charging pumps with no mea,s of isolating the flow path. This would result in at increase in boron inventory in the RCS and could result in a plant shutdown.

Full stroke 5l exercising or partial stroke exercising at cold shutdown l could result in a low temperature overpressurization.

5 ALTERNATE TESTING: Valve will be full stroked during refueling.

l l

l O

McGUIRE - UNIT 2 II.9-11 Revision 5

-. ~

j J.

I.

MC-2576-1.0-a 1

a i-VALVES:

2VP-18, 2VP-2A, 2VP-38, 2VP-4A, 2VP-68, 2VP-7A, 2VP-8B, 2VP-9A, 2VP-10A, 2VP-llB, 2VP-12A, 2VP-138, 2VP-15A,

?

2VP-168, 2VP-17A, 2VP-18B, 2VP-19A, 2VP-20B CATEGORY:-

A 1

' CLASS:

B 4

\\

[

FUNCTION:

Provide containment isolation.

f J

TEST REQUIREMENT:

Cycle and time valves every three months.

i i

BASIS FOR RELIEF:

1

],

Technical Specification 3.6.1.9 places severe restrictions on the operational time and alignment permitted for this i

{

system during normal operation.

2VP-1, 2VP-2, 2VP-3, and 1l 2VP-4 may be opened for only 250 hours0.00289 days <br />0.0694 hours <br />4.133598e-4 weeks <br />9.5125e-5 months <br /> a year at power.

l The rest of the VP valves may not be opened at all during power operation.

ALTERNATE TESTING: Valves will be timed whenever the system is operated or whenever the valves are cycled, and the elapsed time since

-l j

the previous test'has been.three months or greater.

If the valves are operating in a mode where the containment timing spec (T.S. 3.6.l.9) does not apply and are returned to the i

5 closed position prior to a mode where the containment timing spec applies, then timing-the valves after operation will-j not be required.

4 4

i I

i

\\

I i

I l

l McGUIRE

, UNIT 2 II.13-5 i

Revision 5-

h 5

O:

i I

I 1

1 1

I 1

i 9l 2

P O

h* W Mpw%.

  • WFW ww-,,,
  • 8'*N'Whw N"'B'T w-e g.,,

l i

SYSTEM:

CONTAINMENT VENTILATION COOLING WATER FLOW DIAGRAMS:

MC-2604-3.0 i

McGUIRE - UNIT 2 II.15-1

O System: Containment Ventilation Cooling Water 0

j l

N w

a a

a r-

~

l 2

Valve Category U

u a

8 E

YE Valve Number u

o Drawing Number A

B C

D H

H Remarks 5l 2RV-79A B

HC-2604-3.0 K-7 X

CT Isolation time $30 sec.

j LT 5l 2RV-80B B

HC-2604-3.0 K-5 X

CT Isolation time 530 sec.

l LT 2RV-32A B

HC-2604-3.0 K-10 X

CT CS Isolation time <60 sec.

LT X

RF*

~

2RV-33B B

HC-2604-3.0 K-12 X

CT CS Isolation time <60 sec.

LT X

RM 5l 2RV-130 B

HC-2604-3.0 J-12 X

X HT X

RF*

g LT 2RV-77B B

HC-2604-3.0 C-10 X

CT CS Isolation time $60 sec.

LT X

RF*

5l 2RV-76A B

HC-2604-3.0 C-12 X

CT CS Isolation time <60 sec.

l LT X

RF*

e h

.O

()

t v

v System: Containment Ventilation Cooling Water e

E b

?

t d

sE u$

Efl I

?

Valve Category 8, $ U, u

4 8

1: : "

Valve Number o

o A

B C

D H

H Remarks Drawina Number 1

l 2RV-126 B

HC-2604-3.0 B-12 X

X MT X

RF*

LT i

2RV-102B B

HC.504-3.0 C-7 X

CT Isolation time <30 sec.

t LT 1

2RV-101A B

HC-2604-3.0 C-5 X

CT Isolation time <30 sec.

LT 1

I i

i i

5 I I

3 5 l

-l i

McGUIRE - UNIT 2 11.15-3

)

Revision 5 i

MC-2604-3.0 VALVE:

2RV-77B, 2RV-76A, 2RV-32A, 2RV-33B CATEGORY:

A i

CLASS:

B FUNCTION:

Provide containment isolation.

TEST REQUIREMENT:

Cycle and time valve once per quarter.

BASIS FOR RELIEF:

Failure of one of these valves in the closed position would inhibit cooling flow to the containment. This would result in a steep rise in lower containment temperature which could. exceed tech, spec. limits and cause a plant shutdown.

ALTERNATE TESTING: Valve will be cycled and timed during cold shutdowns.

f Ut '

l O

McGUIRE - UNIT 2 II.15-4 l

SYSTEM:

FEEDWATER FLOW DIAGRAMS:

MC-2591-1.1 l

1 l

1 i

l I

McGUIRE - UNIT 2 II.21-1

System:

Feedwater 3

3 S

4 a

2 3

wt a

a 1:

48 g

vaive Cate8ory g

a :a u

o en en 64 i

Valve Number Drawing Number A

B C

D Remarks 2CF-26 B

MC-2591-1.1 11 - 3 X

CT X

CS Isolation time 5 5 sec.

Q 2CF-28 B

HC-2591-1.1 11 - 6 X

CT X

CS Isolation time,1 5 sec.

Q 2CF-30 B

HC-2591-1.1 11 - 9 X

CT X

CS Isolation time 5 5 sec.

Q 2CF-35 B

HC-2591-1.1 11-13 X

CT X

CS Isolation time 5 5 sec.

Q 2CF-129 B

HC-2591-1.1 11 - 3 X

CT X

CS Isolation time 5 10 sec.

Q 5l 2CF-137A

'B MC-2591-1.1 11 - 3 X

CT 1 solation time $ 10 sec.

l 4

2CF-128 B

HC-2591-1.1 11 - 6 X

CT X

CS Isolation time $ 10 sec.

Q

h

  • System:

Feedwater l

l U

u s

3

~

3 1

l 4

a T

N e

g g

Valve Category g

g g

U O

Valve Number Drawina Number A

B C

D Remarks 5l 2CF-136 A B

HC-2591-1.1 H-6 X

CT Isolation time 5 10 sec.

l.

Q 2CF-127 B

HC-2591-1.1 H-10 X

CT X

CS Isolation time 5 10 sec.

Q l

5l 2CF-135 A B

HC-2591-1.1 H-10 X

CT Isolation time 5 10 sec.

l Q

2CF-126 B

HC-2591-1.1 H-13 X

CT X

CS Isolation time 5 10 sec.

Q 5l 2CF-134 A B

HC-2591-1.1 H-13 X

CT Isolation time 5 10 sec.

l Q

2CF-104 B

HC-259l-1.1 X-13 X

CT X

.CS Isolation time 1 5 sec.

Q l

2CF-105 B

HC-2591-1.1 K-9 X

CT X

CS Isolation time 5 5 sec.

Q McCulRE - UNIT 2 11.21-3 Revision 5 l

5 m

+

U System:

Feedwater m

l N

O 8

8 e

u 8

1

?

Q a

l

=

Y Y

d m

Valve Category M

M o

0 8

s a

s Valve Number Drawing Number A

B C

D Remarks 2CF-106 B

HC-2591-1.1 K-5 X

CT X

CS Isolation time 5 5 sec.

Q 2CF-107 B

HC-2591-1.1 K-2 X

CT X

CS Isolation time 5 5 sec.

Q 5l 2CF-151B B

MC-2591-1.1 G-12 X

CT 10 sec. max. operating time l

Q 5l 2CF-153 B B

HC-2591-1.1 F-8 X

CT 10 sec. max. operating time l

Q 5 l 2CF-155B 1

B MC-2591-1.1 F-8 X

CT 10 sec. max. operating time l

Q 5 l 2CF-157 B B

MC-2591-1.1 G-12 X

CT 10 sec. max. operating time f

Q 2CF-17 F

MC-2591-1,1 K-3 X

CT X

CS 5 sec. max. operating time Q

McGUIRE - UNIT 2 11.21-4 Revisi

4 t

A A

a e

3

.y System:

Liquid' Waste Recycle i

i e

i l

U s

~

1 i

4 i

E E

m l

4 R

i a

g Valve Category y

M g

U O

E 5

Valve Number Drawing Number A

B C

D Remarks i

2WL-39A B

MC-2565-1.1 J-5 X

CT RF*

Isolation time $10 sec.

Q j

LT

.)

a 2WL-41B B

MC-2565-1.1 X-5 X

CT RF*.

Isolation time $10 sec.

Q J

LT

)

i 2WL-321A B

MC-2565-7.0 H-7 X

CT RF*

15 sec, max. operating time Q

j LT l

i i'

2WL-322B B

MC-2565-7.0 1-6 X

CT RF*

15 sec. max. operating time i

0 LT i

l 5 l 2WL-385 B

MC-2565-7.0 J-5 X

X MT X

RF*

l 0

LT i

McCUIRE - UNIT 2 II.25-3 Revision 5 r

1

g MC-2565-1.1 VALVE:

2WL-24 CATEGORY:

A, C CLASS:

B FUNCTION:

Provide containment isolation.

TEST REQUIREMENT:

Verify proper valve movement once per three months.

BASIS FOR RELIEF:

The system design does not provide any indication for verifying valve closure upon flow reversal.

ALTERNATE TESTING: Verified closed by leak test performed in accordance with Appendix J.

o O

O McGUIRE - UNIT 2 II.25-4

SYSTEM:

NUCIIAR SAMPLING l

FLOW DIAGRAMS:

MC-2572-1.0 MC-2572-1.1

)

MC-2572-3.0 1

i i

l 4

McGUIRE - UNIT 2 II.30-1

S y

y System:

Nuclear Sampling 8

U N

8 3

0 8

l a

S g

Valve Category g

M g

U O

Valve Number Drawing Number A

B C

D Remarks 2NM-3A B

HC-2572-1.0 K-3 X

CT RF*

Isolation time 515 sec.

Q LT 2NM-6A B

HC-2572-1.0 J-3 X

CT RF*

Isolation time 515 sec.

Q LT 2NM-7B B

MC-2572-1.0 K-6 X

CT RF*

Isolation time $15 sec.

Q LT 5l l

2NM-26B B

HC-2572-1.0 K-8 X

CT RF*

Isolation time SIS sec.

Q LT 2NH-25A B

MC-2572-1.0 K-12 X

CT RF*

Isolation time $15 sec.

Q LT e

b

_____m-__.____._

_, _ _ _ _ _.. _. _ _ _ _ _ _ _ _. ~ _

o 1

3 i

e N

' System: Nuclear Sampling e

I l

U 4

s s

m

~

i U

Y N

e" 3

l Y

d

=

e Valve Category U

M u

8 a

e Valve Number Drawing Number A

B C

D Remarks l

2NM-22A B

MC-2572-1.0 J-12 X

CT RF*

Isolation time <l5 sec.

Q l

1 LT j

i 5l l

l 2NM-420 B

MC-2572-1.0 J-12 X

LT RF*

2NM-421 B

MC-2572-1.0 J-3 X

LT RF*

2NM-72B B

HC-2572-1.1 I-6 X

CT RF*

Isolation time <15 sec.

Q

]

LT I;

4 2NM-758 B'

MC-2572-1.1 I-8 X

CT RF*

Isolation time <15 sec.

l Q

I

~

LT i

i l

2NM-788 B

MC-2572-1.1 I-9 X

CT RF*

1 solation time <15 sec.

l Q

j LT l

1 I

l 2NM-81B B

MC-2572-1.1 I-11 X

CT RF*

Isolation time <15 sec.

I Q

j LT i

i McGUIRE - UNIT 2 11.30-3 f

Revision 5 i

E j

System: Nuclear Sampling E

O E

D e

d a

A

?

R E

~

g j

Valve Category j

t y

O 8

E Y

E Valve Number o

Drawing Number o

A B

C D

H M

H Remarks 2NM-69 B

MC-2572-1.1 G-9 X

LT RF*

Passive 2NM-82A B

MC-2572-1.1 E-9 X

CT RF*

Isolation time $15 sec.

Q LT 2NM-187A B.

MC-2572-3.0 K-1 X

CT Isolation time SIS sec.

Q 2NM-190A B

HC-2572-3.0 K-2 X

CT Isolation time $15 sec.

Q 2NM-?:: B B

HC-2572-3.0 1-2 X

CT Isolation time 515 sec.

Q 2NM-197B B

MC-2572-3.0 K-5 X

CT Isolation time $15 sec.

Q 2NM-2008 B

HC-2572-3.0 K-6 X

CT Isolation time $15 sec.

Q

.~Nei;6U e

e

~E - UNIT 2 11.30-4

a I

SYSTEM:

NUCLEAR SERVICE WATER 4

I FLOW DIAGRAMS:

MC-1574-1.0

~ 1l MC-2574-1.1 l

5l

[

t MC-2574-2.0 MC-2574-2.1 l

MC-2574-3.0

{

MC-2574-3.1 j

MC-2574-4.0 5l MC-2604-3.1 l

4 5l The valves with a "0" prefix found on drawing MC-1574-1.0 are shared l

l by both units. They are covered under the Unit 1 Inservice Testing-l Program, and they are presented here for information only.

4 i

I 4

i

.l 1

1 l

i I

I i

}

i 1

i i

i 1

l t

1 i

i I

McGUIRE - UNIT 2 II,31-1 j

Revision 5

System: Nuclear Service Water

=

u e

3 1

T 3

2 l

4 t

SE m

o Valve Category d

U*

Y O

5 N

5&

Valve Number Drawing Number A

B C

D Remarks 1l ORN-7A C

HC-1574-1.0 J-9 X

CT 60 sec. max. cycle time' l

1 l ORN-2B C

HC-1574-1.0 K-10 X

CT 60 sec. max. cycle time l

1 l ORN-3A C

HC-1574-1.0 K-10 X

CT 60 sec. max. cycle time l

1l ORN-13A C

HC-1574-1.0 J-11 X

CT 60 sec. max. cycle time l

1l ORN-12A C C

HC-1574-1.0 I-11 X

CT 60 sec. max. cycle time l

1l ORN-14A C

HC-1574-1.0 I-13 X

CT 60 sec. max. cycle time l

1l ORN-ISB C

HC-1574-1.0 F-13 X

CT 60 sec. max. cycle time l

1 l ORN-4A C

HC-1574-1.0 F-12 X

CT 60 sec. max. cycle time l

1l ORN-5B' C

HC-1574-1.0 E-12 X

CT 60 sec. max. cycle time l

1l ORN-10A,C C

HC-1574-1.0 G-11 X

CT 60 sec. max. cycle time l

h iulRE - Ul{IT 2 11 Re

.on 1

l l

l l

l l

l l

l l

r 5

e t

n a

3o W

i e

e e

e e

e e

e e

1 s e

m m

m m

m m

m m

m

3. i c

i i

i i

i i

i i

i v

i t

t t

t t

t t

t t

I e v

IR r

e e

e e

e e

e e

e e

l l

l l

l l

l l

l S

c c

c c

c c

c c

c y

y y

y y

y y

y y

r s

c c

c c

c c

c c

c a

k e

r l

a x

x x

x x

x x

x x

c m

a a

a a

a a

a a

a u

e m

m m

m m

m m

m m

N R

c c

c c

c c

c c

c e

e e

e e

e e

e e

m s

s s

s s

s s

s s

e t

0 0

0 0

0 0

0 0

0 s

6 6

6 6

6 6

6 6

6

.y S

4.Agn

,U l* %Ma

.yl~1i* yn T

T T

T T

T T

T T

C C

C C

C C

C C

C y

D rog e

C t

a C

B X

X X

X X

X X

X X

ev la A

V 1

0 0

0 1

1 1

1 9

7 7

6 6

.:a4g8 F

I G

F D

J E

I F

re bm 0

0 0

0 0

0 0

0 0

u N

1 1

1 1

1 1

1 1

1 g

4 4

4 4

4 4

4 4

4 n

7 7

7 7

7 7

7 7

7 i

5 5

5 5

5 5

5 5

5 w

1 1

1 1

1 1

1 1

1 a

r C

C C

C C

C C

C C

D H

H H

H H

H H

H H

  • .3u C

C C

C C

C C

C C

2 T

I N

r U

e b

C, mu A

8 A

B A

8 E

N B

1 2

9 2

0 1

R 1

0 0

8 4

5 5

5 I

e 1

1 3

3 9

1 1

1 1

U v

C l

N N

N N

N N

N N

N c

a R

R R

R R

R R

R R

M V

O O

O O

O O

O O

O l

l l

l l

j l

l l

l 1

1

  • 1 1

1 1

1 1

1 5

.I l

1 l

I i :'

1 l

l h

System: Nuclear Service Water s

\\

0

?

1 a

T Y

d m

e

-l Valve Category y

j g*

Y 0

0 5 5&

Valve Number Drawing Number A

B C

D Remarks 5l l

5l l

5l l

5l l

1 l ORN-147A,C C

HC-1574-1.0 H-2 X

CT 60 sec. max. cycle time l

l 1 l ORN-148A C

HC-1574-1.0 H-3 X

CT 60 sec. max. cycle time l

l 5l l

l 1lORN-283AC C

HC-1574-1.0 F-2 X

60 sec. max. cycle time 1lORN-284B C

MC-1574-1.0 F-2 X

CT 60 sec. max. cycle time l

1 II.31-4 IRE - UNIT 2 Revisi

l AU 5

J

=y System: Nuclear Service Water E

8

=

e 5

1 l

3 a

l Y

M m

e

.g Valve Category g

j g*

0 0

5 S&

Valve Number Drawing Number A

B C

D Remarks -

2RN-170B C

MC-2574-3.0 J-2 X

CT 60 sec. max. cycle time 2RN-171B C

MC-2574-3.0 F-7 X

CT 40 sec. max. cycle time 2RN-174B C

HC-2574-3.0 I-7 X

CT 60 sec. max. cycle time 2RN-162B C

HC-2574-3.0 K-7 X

CT 10 sec. max. cycle time 5l 2RN-213B C

HC-2574-3.0 J-5 X

CT 60 sec. max. cycle time l

l 5l 2RN-218B

.C NC-2574-3.0 J-7 X

CT 60 sec. max. cycle time l

2RN-187B C

MC-2574-3.0 F-12 X

CT 60 sec. max. cycle time 2RN-190B C

HC-1574-3.0 J-12 X

CT 60 sec. max. cycle time 2RN-240B C

MC-2574-3.0 D-13 X

CT 15 sec. max. cycle time i

l McCUIRE - UNIT 2 II.31-9 l

Revision 5 i

l

l

{

1 System: Nuclear Service Water m

E E

8 l

s

?

1 e

er ex:

u l

?

u

\\

?

o nU a

Valve Category e

o e

a eu U

O

$Q l

Valve Number Drawing Number A

B C

D Remarks l

l 2RN-204B C

HC-2574-3.1 C-5 X

CT 15 sec. max. cycle time 2RN-182B C

HC-2574-3.1 I-3 X

CT 60 sec. max. cycle time l

l 2RN-235B C

HC-2574-3.1 E-7 X

CT 60 sec. max. cycle time i

l 2RN-238B C

MC-2574-3.1 I-7 X

CT 60 sec. max. cycle time l

2RN-2278 b

HC-2574-3.1 E-10 X

CT 15 sec. max. cycle time l

2RN-231B C

HC-2574-3.1 C-10 X

CT 15 sec. max. cycle time l

2RN-215B C

MC-2574-3.1 B-11 X

CT 15 sec. max. cycle time 2RN-186B C

HC-2574-3.1 1-12 X

CT 60 sec. max. cycle time i

l b

e "

l

-k

(*

rh

(

System: Nuclear Service Water i

~

1 T

3 e

a T

a t

58 Valve Category y

M g*

U O

5 E

$N Valve Number Drawing Number A

B C

D Remarks 2RN-252B C

MC-2574-4.0 E-2 X

CT X

CS Isolation time <30 sec.

LT 2RN-253A C

HC-2574-4.0 C-2 X

CT X

CS Isolation time 130 sec.

LT i

l l

2RN-276A C

MC-2574-4.0 J-2 X

CT X

CS Isolation time <30 sec.

l LT l

2RN-2778 C

MC-2574-4.0 I-2 X

CT X

CS Isolation time $30 sec.

LT 2RN-42A C

HC-2574-4.0 B-9 X

CT X

CS 60 sec. max. cycle time 2RN-63B C

MC-2574-4.0 L-10 X

CT X

CS 60 sec. max. cycle time I

2RN-64A C

MC-2574-4.0 L-11 X

CT X

CS 60 sec. max. cycle time 5

2RN-279B C

MC-2604-3.1 E-13 X

CT 60 sec. max. cycle time 2RN-299A C

MC-2404-3.1 E-13 X

CT 60 sec. max. cycle time McGUIRE - UNIT 2 II.31-11 Revision 5 l

?

l x

O t

\\

\\

5 (PAGE INTENTIONALLY LEFT BLANK) l l

l l

l I

l

~ 9 l

l l

l

.'4 g

4 O

McGUIRE - UNIT 2 II.31-12 s

Revision 5

s.

MC-2553-2.0 5l VALVE:

2NC-27C, 2NC-29C f

CATEGORY:

B CLASS:

A FUNCTION:

Pressurizer Spray Control TE5T REQUIREMENT:Cycle and time valve quarterly.

BASIS FOR RELIEF:

Valve has nc open or closed indication.

ALTERNATE TESTING: Valve will be verified operable quarterly by partial stroking. A change in RCS pressure will indicate proper valve operation.

~

McGUIRE - UNIT 2 II.32-7 Revision 5

g 5

n r

3 o e

e

- i m

3 s taW

3. i i

v t

I e g

e I R n

l i

c l

y e

s c

u k

f r

e a

x R

m a

e m

R e

m c

v e

e i

t s

s s

s y

0 a

S 3

P S

F

$wu e4 w4g0 C

F R

R

,NsT* tj0 X

X

.yEeal" g0 T

T T

T CQ Ho L

H y

D ro ge C

X X

X ta C

B X

e v

la A

X V

2 1

32Og0 1

1 7

5 C

B D

I re b

m 0

0 0

0 u

N 1

1 1

1 g

1 1

1 1

n 7

7 7

7 i

5 5

5 5

w 2

2 2

2 a

r C

C C

C D

H H

H H

.g0 B

B B

E 2

T r

I e

N b

U m

u N

A E

7 8

7 2

R e

2 2

6 5

I v

U W

W W

W l

C a

c V

2 2

2 2

M l

5

MC-2571-1.0 l

VALVE:

2W-27A CATEGORY:

B CLASS:

B FUNCTION:

Isolates low pressure inj. from RWST.

TEST REQUIREMENT:

Full stroke exercise quarterly.

I BASIS FOR RELIEF:

Closure of this valve would render all low pressure injection inoperable.

ALTERNATE TESTING: Valve will be cycled and timed at cold shutdown.

I l

l l

l l

l McGUIRE - UNIT 2 II.33-4

MC-2571-1.0 VALVE:

2FW-28 CATEGORY:

C CLASS:

B FUNCTION:

Prevents reverse flow to the RWST and prevents pressurizing the RWST.

TEST REQUIREMENT:

Full stroke exercise quarterly.

BASIS FOR RELIEF:

2FW-28 cannot be full stroked during power operation since the only full flow path is into the'RCS by the Residual Heat Removal Pumps (ND). The ND Pumps cannot overcome RCS pressure.

' ALTERNATE TESTING:

Valve will be full stroke exercised at refueling and partial stroked quarterly.

McGUIRE - UNIT 2 11.33-5 Revision 5 New Page O

A

SYSTEM:

RESIDUAL HEAT REMOVAL SYSTEM FLOW DIAGRAMS:

MC-2561-1.0 4

McGUIRE - UNIT 2 II.34-1

m 5

System: Residual lleat Removal m

8 e

u 0

1 T

3 a

l a

t S8 m

o Valve Category U

M UU U

O

$ OM Valve Number Drawing Number A

B C_ D Remarks 2ND-1B A

HC-2561-1.0 1-13 X

CT X

CS 60 sec. max. cycle time 2ND-2A C A

HC-2561-1.0 H-13 X

CT X

CS 60 sec. max. cycle time 2ND-4B B

HC-2561-1.0 E-12 X

CT 60 sec. max. cycle time 2ND-19A B

HC-2561-1.0 11 - 1 2 X

CT 60 sec. max. cycle time 5l 2ND-23 B

HC-2561-1.0 J-8 X

HT X

RF l

5l 2ND-8 B

HC-2561-1.0 D-8 X

HT X

RF l

2ND-18 B

HC-2561-1.0 F-7 X

CT 60 sec. max. cycle time 2ND-33

,B HC-2561-1.0 11 - 7 X

CT 60 sec. max. cycle time 2ND-678 B

HC-2561-1.0 B-9 X

CT 10 sec. max. cycle time 2ND-68A B

HC-2561-1.0 L-9 X

CT 10 sec. max. cycle time

= -.

[

f(

(

\\

s 4

I y

y System: Residual Heat Removal I

U 0

8 m*

s

?

4 a

i 4

4 3

y Valve Category y

M g

?

O 5

0 Valve Number o

Drawina Number A

B C

D Remarks 2ND-71 B

MC-2561-1.0 C-4 X

NT X

RF 2ND-14 B

HC-2561-1.0 D-3 X

CT 60 sec. max. cycle time 2ND-70 B

HC-2561-1.0 K-3 X

NT X

RF 2ND-58A B

MC-2561-1.0 K-3 X

CT X

CS 60 sec. max. cycle time 2ND-29A B

HC-2561-1.0 J-3 X

CT 60 sec. max. cycle time 2ND-15B B

HC-2561-1.0 E-3 X

CT 10 sec. max. cycle time 2NL.-30A B

HC-2561-1.0 I-3 X

CT 10 sec. max. cycle time 2ND-34 B

MC-2561-1.0 G-5 X

CT 60 sec. max. cycle time McCUIRE - UNIT 2 II.34-3

j O

1 MC-2561-1.0 5l VALVE:

2ND-1B, 2ND-2A,C f

CATEGORY:

A CLASS:

A FUNCTION:

Provides suction for Residual Heat Removal Pumps during normal cooldown.

TEST REQUIREMENT:

Verify proper valve movement every three months.

BASIS FOR RELIEF:

These valves have been provided with an interlock which prevents their opening when the Reactor Coolant System pressure is greater than 385 psig.

ALTERNATE TESTING: Valve will be cycled during cold shutdowns.

O O

McGUIRE - UNIT 2 II.34-4 Revision 5 e

l I

4 4

MC-2561-1.0 i

VALVE:

2ND-70 CATEGORY:

C l

CLASS:

B FUNCTION:

RHR to SI Suction Check.

i TEST REQUIREMENT:

Full stroke exercise quarterly.

BASIS FOR RELIEF:

2ND-70 cannot be full stroked during power operation or cold shutdown since the only full flow path is into the RCS and this can only be performed during refueling j

outages when the reactor head is removed. The miniflow for

]

ND Pump 2A does not pass through 2ND-70 so it cannot be 5

partial stroked during power operation or cold shutdown.

5 ALTERNATE TESTING:

2ND-70 will be full stroke exercised at refueling.

i l

i 4

i McGUIRE - UNIT 2 II.34-5 j

Revision.5 1

O MC-2561-1.0 l

5 l VALVE:

2ND-58A CATEGORY:

B CLASS:

B FUNCTION:

Provides suction to the Centrifugal Charging Pumps from the Residual Heat Removal System.

TEST REQUIkEMENT:

Cycle valve every three months.

BASIS FOR RELIEF:

Due to interlocks in the Safety Injection System and the actual Residual Heat Removal System design, it is impossible to test these valves without rendering both trains of Residual Heat Removal and both trains of Safety Injection inoperable during operation.

ALTERNATE TESTING: Cycle and time at cold shutdown.

O O

McGUIRE - UNIT 2 II.34-6 Revision 5

MC-2561-1.0 rO

' \\.

VALVE:

2ND-71 CATEGORY:

C CLASS:

B FUNCTION:

RHR to SI Suction Check.

TEST REQUIREMENT:

Full stroke exercise quarterly.

BASIS FOR RELIEF:

Valve cannot be full stroked at power since the only full flow path is into the RCS and this can only be done with the reactor head removed at refueling.

2ND-71 cannot be partial stroked during power since the required valve lineup would render both trains of safety injection inoperable. During cold shutdown, both SI pumps are tagged out to prevent a low tempera-ture overpressurization.

ALTERNATE TESTING: Valve will be full stroked at refueling.

O

~

~G

~

O McGUIRE - UNIT 2 11.34-7

O MC-2561-1.0 VALVE:

2ND-8, 2ND-23 CATEGORY:

C CLASS:

B FUNCTION:

Prevents reverse flow through the ND Pumps TEST REQUIREMENT:

Full stroke exercise quarterly BASIS FOR RELIEF:

2ND-8 and 2ND-23 cannot be full stroked during power operation since the only full flow path is into the RCS and the ND Pumps cannot overcome RCS pressure.

ALTERNATE TESTING:

Valves will be full stroke exercised at refueling and partial stroked quarterly.

~

G

)

O McGUIRE - UNIT 2 II.34-8 Revision 5 New Page

O O

O 3

t System: Safety Injection a

3 e

1

.B m

0 E

a i

w e

u a

3 y

Valve Category j

t y

4 8

0 Valve Number u

Drawina Number o

A B

C D

H M

H Remarks 2NI-354 A

HC-2562-1.0 K-7 X

HT X

RF 1

2NI-431B B

HC-2562-2.0 J-4 X

CT X

CS 60 sec. max. cycle time 4

t 2NI-70 A

HC-2562-2.0 H-13 X

X LT X

CS NT RF 2NI-71 A

HC-2562-2.0 H-14 X

X LT X

CS SI nr I

2NI-430A B

HC-2562-2.0 E-4 X

CT X

CS 60 sec. max. cycle time 2NI-59 A

HC-2562-2.0 D-13 X

X LT X

CS NT RF 2NI-60 A

HC-2562-2.0

.D-14 X

X LT X

CS 5l HT l

4 McCUIRE'- UNIT 2 11.35-3 Revision 5 3

i

5 0

Y System: Safety injection E

O

{

S a

a a

?

a N

S a

i u

E E

Valve Category 0

U u

d a

Valve Number Dr.:ving Number A

B C

D Remarks 2NI-47A B

HC-2562-2.0 K-5 X

CT Isolation time $15 sec.

LT 2NI-48 B

HC-2562-2.0 K-3 X

X HT RF*

LT X

2NI-81 A

HC-2562-2.1 C-3 X

X LT X

CS HT RF 2NI-82 A

HC-2562-2.1 C-3 X

X LT X

CS 5l HT l

2NI-93 A

HC-2562-2.1 C-8 X

X HT X

CS 5l LT RF l

2NI-94 A

HC-2562-2.1 C-8 X

X HT X

CS LT 2NI-95A B

HC-2562-2.1 F-11 X

CT Isolation time $10 sec.

LT McGUIRE - UNIT 2 11.35-4

-l Revisi

e System:

Safety Injection E

O E

E E

e E

a

?

a"

?

a R

a W

~

?

Valve Category

,8l t

u M

S E

Y E

Valve Number u

u A

B C

D H

88 H

Remarks Drawing Number i

2NI-96B B

HC-2562-2.I E-14 X

CT Isolation time $10 sec.

LT 2NI-436 B

MC-2562-2.1 G-11 X

X HT X

RF*

Passive LT l

2NI-334B B

HC-2562-3.0 L-11 X

CT 10 sec. max. cycle time l

2NI-333B B

HC-2562-3.0 L-12 X

CT 10 sec. max. cycle time l

l 5 l 2NI-332 A B

HC-2562-3.0 L-14 X

CT 10 sec. max. cycle time l

l 2NI-136B B

HC-2562-3.0 C-14 X

CT 10 sec. max. cycle time l

2NI-103A B

HC-2562-3.0 I-14 X

CT 10 sec. max. cycle time l

l 2NI-101 B

HC-2562-3.0 F-14 X

HT X

McGUIRE - UNIT 2 II.35-5 Revision 5

0 U

System:

Safety Injection E

O 0

a e

?

a A

S a

j

~

2 Valve Category d

u u

M E

Y E

o" H

H Valve Number Drawing Number A

B C

D Remarks 2NI-100B B

HC-2562-3.0 F-13 X

CT X

CS 10 sec. max. cycle time 2NI-135B B

HC-2562-3.0 E-14 X

CT 10 sec. max. cycle time 2NI-114 B

HC-2562-3.0 I-9 X

HT 2NI-115B B

HC-2562-3.0 11 - 9 X

CT 10 sec. max. cycle time 2NI-147A B

HC-2562-3.0 G-11 X

CT X

CS 10 sec. max. cycle time 2NI-144B B

HC-2562-3.0 G-9 X-CT 10 sec. max. cycle time 2NI-143 B

HC-2562-3.0 F-9 X

HT 2NI-116 B

HC-2562-3.0 J-9 X

HT X

RF 2NI-148 B

HC-2562-3.0 D-9 X

HT X

RF 2NI-118A B

HC-2562-3.0 11 - 7 X

CT 10 sec. max. cycle time Mc E - UNIT 2 II.35-6

\\

O Y

System: Safety Injection E

O l

m w

s u

0 e

a l

~<

M m

c:

3 E

Valve Category ij u

8 1

u u

Valve Nienber Drawina Nunher A

'B C

D H

H Remarks 2NI-2428 8

HC-2562-4.0 E-8 X

CT 3 sec. max. cycle time 2NI-245A B

HC-2562-4.0 F-7 X

CT 3 sec. max. cycle time 2NI-243A B

HC-2562-4.0 E-7 X

CT 3 sec. max. cycle time 5l 2NI-258A B

HC-2562-4.0 F-5 X

CT 10 sec. max. cycle time l

i 2NI-2558 B

HC-2562-4.0 F-5 X

CT 10 sec. max. cycle time l

1 4l 2NI-248 A

HC-2562-4.0 E-5 X

X LT X

RF#

l NT i

}

4l 2NI-249 A

HC-2562-4.0 E-3 X

X LT X

RF#

l HT 2NI-266A A

HC-2562-4.0 E-3 X

CT Isolation time <10 sec.

1 LT r

i 2NI-267A A

HC-2562-4.0 E-4 X

CT Isolation time $10 sec.

LT i

i McGillHE - IINIT 2 11.35-11 l

Revision 5 i

I l,

i 1

9

{

U System: Safety Injection l

U E

O p

1 l

4 Y

d d

e e

g y

Valve Category g

y g

a o

e e

e Valve Number Drawina Number d

A B

C D

Remarks 5l 2NI-336 B

HC-2562-4.0 G-2 X

X LT Passive l

2NI-264 B

HC-2562-4.0 G-3 X

CT Isolation time $10 sec.

LT 2NI-253 A

HC-2562-4.0 C-6 X

X LT X

RF HT 2NI-252 A

HC-2562-4.0 C-4 X

X LT X

RF HT 2NI-251 A

HC-2562-4.0 C-3 X

X LT X

RF HT 2NI-250 A

HC-2562-4.0 C-2 X

X LT X

RF HT UHI Rupture B

HC-2562-4.0 I-8 X

Tested per tech. spec.

Disc II.35-12 McCUIRE - UNIT 2 Revision <

i 1

i MC-2562-3.1

)

VALVE:

2NI-180, 2NI-181, 2NI-175, 2NI-176 CATEGORY:

A, C CLASS:

A FUNCTION:

Opens on flow from the ND or NI to NC System.

1 TEST REQUIREMENT:

Verify valve opens on flow from NI or ND System to the NC System once per three months.

BASIS FOR RELIEF:

The discharge pressure of the NI and ND Pumps is not sufficient for opening the valve to the Reactor Coolant 1

System during power operation.

ALTERNATE TESTING: Valve will be tested for proper movement during cold shutdowns, but not more often than once per nine months.

O O

McGUIRE - UNIT 2 II. 35-29

O MC-2563-3.1 5l VALVE:

2NI-1848, 2NI-185A l

CATEGORY:

B CLASS:

B FUNCTION:

Isolate the containment sump (2NI-184 isolates train B, 2NI-185 isolates train A).

These valves also provide an alternate source for suction to the Residual Heat Removal Pumps.

BASIS FOR RELIEF:

Due to interlocks in the Safety Injection System and the actual Residual Heat Removal design, it is impossible to test these valves without rendering both trains of Residual Heat Removal and both trains of Safety Injection inoperable. During cold shutdowns, the RHR pumps are required for decay heat removal.

ALTERNATE TESTING:

Full stroke exercise during refueling.

f i

l e

i 1

McGUIRE - UNIT 2 II.35-30 Revision 5