May 1, 1986  ;

l Docket No. 50-267 Mr. R. F. Walker, President Public Service Company of Colorado Post Office Box 840 Denver, Colorado 80201-0840

Dear Mr. Walker:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - FORT ST. VRAIN, BUILDING I 10 ELECTRICAL MODIFICATIONS (TAC 55287) 1 The staff has reviewed Public Service Company of Colorado's submittals  ;

concerning its electrical modifications to Building 10 at Fort St. Vrain, j and has determined that additional information is needed to complete the '

review.

Enclosed are fourteen questions that define the additional information needed for this review. We request that you respond to these questions within 45 days of the date of this letter. If you have any questions, please contact Charles Hinson at (301) 492-7930.

The information requested in this letter affects fewer than 10 respondents; therefore, OMB clearance is not required under P.L.96-511.

Sincerely, i

Original signed by Kenneth L. Heitner, Project Manager Standardization and Special Projects Directorate Division of PWR Licensing-8, NRR

Enclosure:

As stated cc w/ enclosure:  !

See next page DISTRIBUTION:

RDocket Filey' KHeitner

'SSPD Reading 0 Lynch ,

NRC PDR HBerkow '

Local PDR ANolan, EG&E, Idaho, Inc.

DCS IAhmed PNoonan CHinson

) - :SSPD JCalvo DPWRL-B:SSPD

%4 l DPWRL-B:SSPD DP@ - SSPD DJW SPD E CHinso g $ KHeitner:ac OlyM ,

H8e w 01 /86 04/g)/8 04/L9/86 Q4fj /86 Qy j/86 8605090492 860501 I PDR ADOCK 050002673 P PDR g

, - < w 'm s - - -

l

  1. o,, UNITED STATES h

-[5 :j g NUCLEAR REGULATGRY COMMISSION WASHINGTON, D. C,20555

%,,,,,,,/ May 1, 1986 Docket No. 50-267 Mr. R. F. Walker, President Public Service Company of Colorado '

Post Office Box 840 Denver, Colorado 80201-0840

Dear Mr. Walker:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - FORT ST. VRAIN, BUILDING 10 ELECTRICAL MODIFICATIONS (TAC 55287)

The staff has reviewed Public Service Company of Colorado's submittals concerning its electrical modifications to Building 10 at Fort St. Vrain, and has determined that additional information is needed to complete the review.

j Enclosed are fourteen questions that define the additional information ^

needed for this review. We request that you respond to these questions within 45 days of the date of this letter. If you have any questions, '

please contact Charles Hinson at (301) 492-7930.

The information requested in this letter affects fewer than 10 respondents; therefore, OMB clearance is not required under P.L.96-511.

Sincerely, 3A J I,s h

~

Kenneth L. Heitner, Project Manager Standardization and Special  :

Projects Directorate Division of PWR Licensing-8, NRR

Enclosure:

As stated cc w/ enclosure:

See next page

- _. _ ~

P o Mr. R. F. Walker Public Service Company of Colorado Fort St. Vrain cc:

Mr. D. W. Warembourg, Manager Albert J. Hazle, Director Nuclear Engineering Division Radiation Control Division Public Service Company Department of Health of Colorado 4210 East lith Avenue P. O. Box 840 Denver, Colorado 80220 Denver, Colorado 80201 Mr. David Alberstein, 14/159A Mr. J. W. Gahm, Manager i GA Technologies, Inc. Nuclear Production Division

  • Post Office Box 85608 Public Service Company of Colorado San Diego, California 92138 16805 Weld County Road 19-1/2 Platteville, Colorado 80651 Mr. H. L. Brey, Manager Nuclear Licensing and Fuel Division Mr. L. W. Singleton, Manager ,

Public Service Company of Colorado Quality Assurance Division  ;

P. O. Box 840 Fort St. Vrain Nuclear Station l Denver, Colorado 80201 16805 Weld County Road 19-1/2 -

Platteville, Colorado 80651 Senior Resident Inspector .

U.S. Nuclear Regulatory Commission  !

P. 0. Box 640 Platteville, Colorado 80651 Kelley, Stansfield & 0'Donnell Public Service Company Building Room 900 ,

550 15th Street >

Denver, Colorado 80202 '

Regional Administrator, Region IV .

U.S. Nuclear Regulatory Commission '

611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 ,

Chairman, Board of County Commissioners of Weld County, Colorado Greeley, Colorado 80631 Regional Representative Radiation Programs l Environmental Protection Agency '

1800 Lincoln Street )

Denver, Colorado 80203 l

- - n -e, -

y. -

e- a , , . --e,. - , , - - - -

+

ENCLOSURE REQUEST FOR ADDITIONAL INFORMATION CONCERNING ELECTRICAL MODIFICATIONS AT FORT ST. VRAIN We have reviewed the submittals from the Public Service Company (PSC) of Colorado, the licensee for the Fort St. Vrain Nuclear Generating Station, concerning the upgrading of the essential 4160-/480-volt power distribution system in Building 10. As a result of this review, we request the following additional informationt Q1. A letter from the Proto-Power Management Corporation (dated November 19, 1982) attached to CN-1462, described three safety-related concerns related to the fire study. These concerns are as follows: 1) the cables for inverters 1A and IB are in the same fire area, 2) the cables for inverters 1A and 1C r are in the same fire area, and 3) emergency lighting was not included in the design for Building 10. Provide a discussion as to how these concerns have been resolved.

,, Q2. In Table 3 of Attachment "A" to letter P-84230 (PSC to NRC),

l dated July 25, 1984, a temperature of 120*F was listed for j Building 10. Confirm that all Class 1E power, control, and I

instrumentation cables in Building 10 have been qualified for an ,

j environment of 120*F.

d Q3. The bus designation shown in CN-1332B is different from that shown on Figure 8.2-13, and some of the buses mentioned in  ;

CN-1332B are not shown on Figure 8.2-13 (e.g., interruptible bus 2 is not shown on the drawing; non-interruptible busses 1C and

, IC-1 are referred to as "non-interruptible bus 3" in text).  ;

Provide the correct information.

l t

! Q4. CN-1332B calls for the installation of electrical equipment on the mezzanine; however, the fire study (CN-1462) states that no  !

electrical equipment was mounted on the mezzanine when the study was made. Has the fire study been re-done or modified to include  !

the new equipment mounted on the mezzanine? Provide the fire '

study information for all new equipment installed in Building 10, including that installed on the mezzanine.

QS. CN-1332B shows that inverter 1C is powered from two different essential buses (1 and 2), instead of from a single essential bus, as is the case for inverters 1A and IB. Which division does inverter 1C belong to, and what safety-related system does it serve? Are these systems required for safe shutdown of the plant?

Q6. Figure 8.2-13 in CN-1332 does not show the inverter IC tie-in to the DC bus; however, this tie-in is shown in the same figure in r

T

,.m., ...,$ . % .. ..._.-.___.___,-w,_.... , _ - . . . _ . _y. , ..., my.._ , , , _ . . . , , , _

- . _ _ -...,..x ..y,

w s

CN-1332B. CN-1332 and CN-1332B appear to be the same, with some subtle differences. Does the DC bus tie-in exist? Also, correct Figure 8.2-13.

Q7. For the work called for in CN-1332, provide data showing that the installed cables (existing or new) have been analyzed to determine if they can handle the higher short circuit currents that are now available, taking the maximum temperature conditions into account.

Q8. CN-1391 provides for installing batteries which have a greater amp-hour capacity than the existing batteries, but does not provide for upgrading the power cables. Confirm that the existing cables will handle the higher (by a factor of 2) short circuit currents that are now available.

09. CN-1391 states that the battery capacity was increased to accommodate existing overloads, as indicated in Section 3-C of CN-1391. This overload should be reflected in the performance test of the battery discharge rate, as indicated in the design analysis,Section XII of CN-1391. Confirm that the battery discharge tests have been upgraded to reflect the new load conditions.

Q10. It is not clear from CN-1294 if old circuit breakers and switchgear are being kept and used. In addition, neither the old l

versus new KVA ratings of the electrical equipment nor the size of new loads are stated. Provide this information.

Q11. CN-1294 states that the AC circuit breakers are fused. Supply j the design details for the fused circuit breakers, details on how proper coordination is accomplished, and details on how expected l single phasing, due to the fuses, is to be handled. l l

l Q12. CN-1294 calls for the installation of current-limiting reactors l on the input feeders to the safety-related motor control centers. I Provide details about how the voltage regulation was established on the Class IE 480/120 volt buses and provide the voltage study, i Q13. Submit the following documents which are required for our review:

a) CN-1781 b) CN-1605, all revisions c) CN-1629 Q14. With respect to CN-1332 (all revisions), CN-1391, CN-1272, and CN-1255:

a) List the applicable codes, standards, regulatory  ;

requirements, and design requirements used in the <

modifications and noted in Item 4 " Check List of Design Verification Questions for Design Review Method" of the above CNs.

b)' Supply.the information and data necessary for our review of the design requirements that have been identified in Item 15

~" Check List of Design Verification Questions for Design Review Method" of the above CNs.