Amend 203 to License DPR-16,modifying Spec 6.2.2(a) to Provide Some Flexibility to Accomodate Unexpected Absense of on-duty Shift Crew Members
ML20196E257
Person / Time
Site: Oyster Creek
(DPR-16-A-203)
Issue date: 11/30/1998
From: Thomas C
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20196E266 List:
References
NUDOCS 9812030078
Download: ML20196E257 (16)


Text

..

e tarog s

g UNITED STATES i

g j

NUCLEAR REGULATORY COMMISSION r%{ @T /g WASHINGTON, D.C. 20066 0001 t

GPU NUCLEAR. INC.

JERSEY CENTRAL POWER & LIGHT COMPANY DOCKET NO. 50-2L9 OYSTER CREEK NUCLEAR GENERATING STATION AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 203 License No. DPR-16 1.

The Nuclear Regulatory Commission (the Commission) his found that:

1 A.

The application for amendment by GPU Nuclear, Inc. et al., (the licensee), dated July 21,1998, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regu!ations of the Commission; C.

There is reasonable assurance: (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health ano afety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

i 4

9812030078 981130 PDR ADOCK 05000219 p

PDR

. = _ _ _.

_ _= _

l 2.

Accordingly, the license is amended by changes to the Technical Specifications as Indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-16 is hereby amended to read as follows:

(2)

Technical Soecificatiom l

The Technical Specifications contained in Appendices A and B, as revised i

through Amendment No.203are hereby incorporated in the license. GPU Nuclear, Inc. shall operate the facility in accordance with the Technical Specifications.

l 3.

This license amendment is effective as of the date of issuance, M be implemented within 30 days, FOR THE NUCLEAR REGULATORY C,N'*;.iC? ION skh-M&

Cecil O. Thomas, Director Project Directorate 1-3 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: November 30, 1998

4 4

ATTACHMENT TO LICENSE AMENDMENT NO203 FACILITY OPERATING LICENSE NO. DPR-16 DOCKET NO. 50-219 Replace the following pages of the Appendix A, Technical Specifications, with the attached pages as indicated. The revised pages are identified by amendment number and contain vertical lines indicating the areas of change.

Remove Insad 2.3-7 2.3-7 3.3-5 3.3-5 3.3-8a 3.3-8a 3.7-4 3.7-4 3.8-2 3.8-2 6-1 6-1 6-2 6-2 6-2a 6-2a 6-3 6-3 6-5 6-5 6-6 6-6 6-8 6-8 6-9 6-9 I

l

}

The low level water level trip setting of I l'5" above the top of the active fuel has been established to assure that the reactor is not operated at a water level below that for which the fuel cladding integrity safety limit is applicable. With the scram set at this point, the generation of steam, and l

thus the loss ofinventory is stopped. For example, for a loss of feedwater flow a reactor scram at the value indicated and isolation valve closure at the low-low water level set point results in more than 4 feet of water remaining above the core after isolation (6). The TAF definition of 353.3 inches from vesse! zero is based on a fuel length of 144 inches and it is applicable to the current fuellength of145.24 inches.

l l

During periods when the reactor is shut down, decay heat is present and adequate water level must be maintained to provide core cooling. Thus, the low-low level trip point of 7'2" above the l

core is provided to actuate the core spray system (when the core spray system is required as l

identified in Section 3.4) to provide cooling water should the level drop to this point.*

i

. The turbine stop valve (s) scram is provided to anticipate the pressure, neutron flux, and heat flux i

increase caused by the rapid closure of the turbine stop valve (s) and failure of the turbine bypass system.

i The generator load rejection scram is provided to anticipate the rapid increase in pressure and neutron flux resulting from fast closure of the turbine control valves to a load rejection and failure of the turbine bypass system. This scram is initiated by the loss of turbine acceleration relay oil pressure. The timing for this scram is almost identical to the turbine trip.

The undervoltage protection system is a 2 out of 3 coincident logic relay system designated to i

shift emergency buses C and D to on-site power should normal power be lost or degraded to an unacceptable level. The trip points and time delay settings have been selected to assure an adequate power source to emergency safeguards systems in the event of a total loss of normal power or degraded conditions which would adversely affect the functioning of engineered safety features connected to the plant emergency power distribution system.

- References (1)

FDSAR, Volume 1, Section VII-4.2.4.2 (2)

FDSAR, Amendment 28, Item III.A-12 (3)

FDSAR, Amendment 32, Question 13 (4)

Letters, Peter A. Morris, Director, Division of Reaction Licensing, USAEC, to John E.

Logan, Vice President, Jersey Central Power and Light Company (5)

FDSAR, Amendment 65, Section B.XI (6)

FDSAR, Amendment 65, Section B.IX i

i j'

' OYSTER CREEK 2.3-7 Amendment No. 175,195 203

  • Correction 11/30/87

Tr:nsformrtion temperature. The minimum temperature for pressurization at any time in life has to account for the toughness properties in the most limiting regions of the reactor vessel, as well as the l'

effects of fast neutron embrittlement.

Curves A, B and C on Figures 33.1,33.2 and 333 are derived from an evaluation of the fracture 2

l toughness properties performed on the specimens contained in Reactor Vessel Materials Surveillance Program Capsule No. 2 (Reference 14). The results of dosimeter wire analyses (Reference 14) indicated that the neutron fluence (F>l.0 MeV) at the end of 32 effective full power years of operation is 236 x 1018 n/cm2 at the 1/4T(T= vessel wall thickness) location. This value was used in the calculation of the adjusted reference nil-ductility temperature which, in turn, was used to generate the pressure-temperature curves A, B and C on Figures 33.1,33.2 and 333 (Reference 15). The 250*F maximum pressure test temperature provides ample margin against violation of the minimum required temperature. Secondary containment is notjeopardized by a steam leak during pressure testing, and the Standby Gas Treatment system is adequate to prevent unfiltered release to the stack.

Stud tensioning is considered significant from the standpoint of brittle fracture only when the preload exceed approximately 1/3 of the final design value. No vessel or closure stud minimum temperature requirements are considered necessary for preload values below 1/3 of the design preload with the vessel depressurized since preloads below 1/3 of the design preload result in vessel closure and average bolt stresses which are less than 20% of the yield strengths of the vessel and bolting materials. Extensive service experience with these materials has confirmed that the probability of brittle fracture is extremely remote at these low stress levels, irrespective of the metal temperature.

The reactor vessel head flange and the vessel flange in combination with the double "O" ring type seal are designed to provide a leak tight seal when bolted together. When the vessel head is placed on the reactor vessel, only that portion of the head flange near the inside of the vessel rests on the vessel flange. As the head bolts are replaced and tensioned, the vessel head is flexed slightly to bring together the entire contact surface adjacent to the "O" rings of the head and vessel flange. The original Code requirement was that boltup be done at qualification temperatures (T3OL) plus 60' F.

Current Code requirements state (Ref.16) that for application of full bolt preload and reactor pressure up to 20% of hydrostatic test pressure, the RPV metal temperature must be at RTNDT or greater. The boltup temperature of 85* F was derived by determining the highest value of(T3OL + 60) and the highest value of RTNDT, and by choosing the more conservative value of the two. Calculated values of(T3OL + 60) and RTNDT of the RPV metal temperature were 85' F and 36' F, respectively (Ref.

15). Therefore, selecting the boltup temperature to be 85' F provides 49*F margin over the current Code requirement based on RTNDT-Detailed stress analyses (4) were made on the reactor vessel for both steady state and transient conditions with respect to material fatigue. The results of these analyses are presented and compared i

to allowable stress limits in Reference (4). The specific conditions analyzed currently include 240 i

cycles (17) of nonnal startup and shutdown with a heating and cooling rate of 100* F per hour applied continuously over a temperature range of 100* F to 546' F and for 10 cycles of emergency cooldown at a rate of 300* F per hour applied over the same range. A review of the original analysis shows that the components with the highest fatigue usage factor are the reactor vessel studs and reactor vessel j

basin seal skirt. These components have the potential to exceed the allowable fatigue usage factor if the number of thermal cycles (i.e., heatup/cooldown) exceed design assumptions. The number of l

heatup and cooldown cycles was reanalyzed, as documented by Reference (17), for a higher number j

of cycles (240) than expected in the original analysis (120). The reanalysis confirmed that the j

odginal fatigue usage factor limit of 0.8 is maintained. All other components have relatively low usage factors and are not expected to exceed the fatigue usage factor limit of 0.8 for the design life of

)

40 years. Thermal stresses from this analysis combined with the primary load j

OYSTER CREEK 33-5 Amendment No: 15,12,120,!!!,!.o 203 l

i 1

l

References:

(1)

FDSAR, Volume I, Section IV-2 (2)

Letter to NRC dated May 19,1979, " Transient of May 2,1979" (3)

General Electric Co. Letter G-EN-9-55, " Revised Natural Circulation Flow Calculation", dated May 29,1979 (4)

Licensing Application Amendment 16, Design Requirements Section (5)

(Deleted)

(6)

FDSAR, Volume I, Section IV-2.3.3 and Volume II, Appendix H (7)

FDSAR, Volume I, Table IV-2-1 (8)

Licensing Application Amendment 34, Question 14 (9)

Licensing Application Amendment 28, Item III-B-2 (10)

Licensing Application Amendment 32, Question 15 (11)

(Deleted)

(12)

(Deleted)

(13)

Licensing Application Amendment 16, Page 1 (14)

GPUN TDR 725 Rev. 3: Testing and Evaluation ofIrradiated Reactor Vessel Materials Surveillance Program Specimens (15)

GENE-B13-01769 (GE Nuclear Energy): Pressure-Temperature Curves Per Regulatory Guide 1.99, Revision 2 for Oyster Creek Nuclear Generating Station.

(16)

Paragraph G-2222(C), Appendix G,Section XI, ASME Boiler and Pressure Vessel Code,1989 Edition with 1989 Addenda, " Fracture Toughness Criteria for Protection Against Failure."

(17)

GPUN Safety Evaluation, SE-000221-004, " Reactor Vessel Thermal Cycles".

l OYSTER CREEK 3.3-8a Amendment No: 135, "^, !!!, !!! 203

__.m_

1 As indicated in Amendment 18 to the Licensing Applic:. tion, there are num:rous sources of di:sel fuel which can be obtained within 6 to 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and the heating boiler fuel in a 75,000 gallon tank on the b

site could also be used. As indicated in Amendment 32 of the L

Licensing Application and including the Security System loads, the load requirement for the loss of offsite power would require 12,410 gallons for a three day supply. For the case ofloss of offsite power plus loss-of-coolant plus bus failure 9790 gallons would be required for a three day supply.

l In the case ofloss of offsite power plus loss-of-coolant with both diesel generators starting the load requirements (all equipment operating) shown there would not be three days' supply. However, L

not all of this load is required for three days and, after evaluation of the conditions, loads not required on the diesel will be curtailed.. It is reasonable to expect that within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> conditions can be evaluated and the following loads curtailed:

1.'

One Core Spray Pump 2.

One Core Spray Booster Pump l

3.

One Control Rod Drive Pump 4.

One Containment Spray Pump 5.

One Emergency Service Water Pump With these pieces of equipment taken off at 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> after the incident it would require a total consumption of 12,890 gallons for a three day supply. Therefore, a minimum technical specification i

requirement of 14,000 gallons of diesel fuel in the standby diesel generator fuel tank will exceed the engineered safety features

< operational requirement after an accident by approximately 9%.

During plant cold shutdown or refueling, it may be necessary to inspect, repair and replace the 15,000 gallon standby diesel generator fuel storage tank. This would require tank partial or full drain down. An alternate fuel supply configuration may be established which consists of temporary tanker trucks capable of containing 14,000 gallons. This configuration is capable of supporting continuous operation of both diesels for at least 3 days.

The temporary configuration is acceptable since a minimal power load would be required during and following a design basis condition of a loss of offsite' power while the plant is in cold shutdown or refueling. Analysis shows that in the event of a tornado or seismic event which may cause a loss of offsite power and a temporary loss of the temporary EDG fuel oil supply, power can be restored before the consequences of previously analyzed conditions are exceeded.

References:

l (1)~

Letter, Ivan R. Finfrock, Jr. to the Director of Nuclear Reactor Regulation dated April 4,1978.

l OYSTER CREEK 3.7-4 Amendment No.g03

i Each condenser containing a minimum total water volume of 22,730 gallons provides 11,060 gallons above the condensing tubes. Based on scram from a reactor power level of 1950 MWt (the design basis power level for the isolation condensers) the condenser system can accommodate the reactor decay heat (2,3) (corrected for U-239 and NP-239) for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and 40 minutes without need for makeup water. One condenser with a minimum water volume of 22,730 gallons can accommodate the reactor decay heat for 45 l

minutes after scram from 1950 MWt before makeup water is required. In order to accommodate a scram from 1950 MWt and cooldown, a total of 107,500 gallons of J

makeup water would be required either from the condensate storage tank or from the fire i

protection system. Since the rated reactor power is 1930 MWt, the above calculations l

represent conservative estimates of the isolation condenser system capability.

I The vent lines from each of the isolation condenser loops to the main steam lines l

downstream of the main steam lines isolation valves are provided with isolation valves which close automatically on isolation condenser actuation or on signals which close the main steam isolation valves. High temperature sensors in the isolation condenser and pipe l

areas cause alarm in the control room to alert the operator of a piping leak in these areas.

Specification 3.8.E allows reduction in redundancy ofisolation capability for isolation condenser inlet (steam side) isolation valves. Reaconable assurance ofisolation capability is provided by testing the operability of the redundant valve. Specification 3.8.F allows short term inoperability of the AC motor-operated isolation condenser outlet (condensate return) valve. It is not necessary to test the redundant DC motor-operated valve as this valve is normally in the closed position. These specifications permit troubleshooting and repair as well as routine maintenance, such as valve stem packing addition or replacement, l

to be performed during reactor operation without reducing the redundancy of the isolation condenser heat sink function. The out of service time of 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> is consistent with that permitted for primary containment isolation valves.(5)

Either of the two isolation condensers can accomplish the purpose of the system. If one condenser is found to be inoperable, there is no immediate threat to the heat removal capability for the reactor and reactor operation may continue while repairs are being made.

Therefore, the time out of service for one of the condensers is based on considerations for a one out of two system.(4) The test interval for operability of the valves required to place the isolation condenser in operation is once/ month (Specification 4.8). An acceptable out of service time, T, is then determined to be 10 days. However, if at the time the failure is discovered and the repair time is longer than 7 days, the reactor will be placed in the cold shutdown condition. If the repair time is not more than 7 days the reactor may continue in operation, but as an added factor of conservatism, the motor operated isolation condenser and condensate makeup valves on the operable isolation condenser are verified operable daily. Expiration of the 7 day period or inability to meet the other specifications requires that the reactor be placed in the cold shutdown condition l

which is normally expected to take no more than 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br />. The out of service allowance l

when the system is required is limited to the run mode in order to require system l

availability, including redundancy, at startup.

l OYSTER CREEK 3.8-2 Change No. 7 203 Amendment No.: 72, $5 i

3 y

4

,,p r-.

m_

9 ADMINISTRATIVE CONTROLS 6.1 RESPONSIBILITY 6.1.1 The Vice President & Director Oyster Creek shall be responsible for overall facility operation.

Those responsibilities delegated to the Vice President & Director as stated in the Oyster Creek Technical Specifications may also be fulfilled by the Director - Operations and Maintenance.

The Vice President & Director shall delegate in writing the succession to this responsibility during his and/or the Director - Operations and Maintenance absence.

6.2 ORGANIZATION 6.2.1 Coroorate 1

6.2.1.1 An onsite and offsite organization shall be established for unit operation and corporate management. The onsite and offsite orgamzation shall include the positions for activities affecting the safety of the nuclear power plant.

6.2.1.2 Lines of authority, responsibility and communication shall be established and defined from the highest management levels through intermediate levels to and including operating organization positions. These relationships shall be documented and updated as appropriate, in the form of organizational charts. These organizational charts will be documented in the Updated FSAR and updated in accordance with 10 CFR 50.71c.

6.2.1.3 The President - GPU Nuclear shall have corporate responsibility for overall plant nuclear safety and shall take measures needed to ensure acceptable performance of the staffin operating, maintaining, and providing technical support in the plant so that continued nuclear safety is assured.

6.2.2 FACILITY STAFF 6.2.2.1 The Vice President & Director Oyster Creek shall be responsible for overall unit safe operation and shall have control over those onsite activities necessary for safe operation and maintenance of the plant.

6.2.2.2 The facility organization shall meet the following:

a.

Each on duty shift shall include at least the following shiA staffing:

One (1) group shiA supenisor

.Two (2) control room operators Three (3) equipment operators - one may be a Radwaste Operator e

j One (1) Shift Technical Advisor (see h. below) e Except for the group shiA supervisor, shift crew composition may be one less than the minimum requirements, for a period of time not to exceed two hours, in order to accommodate unexpected absence of on-duty shiA crew members.

immediate action must be taken to restore the shiA crew composition to within l

requirements given above. This provision does not permit any shift crew position to be unmanned upon shift change due to an incoming shift crew member being late or absent.

i b.

At all times when there is fuel in the vessel, at least one licensed senior reactor operator shall be on site and one licensed reactor operator should be at the controls.

OYSTER CREEK 6-1 Amendment No.: 54,50,55,50,102,134,104,105 203

--.-~

At all times when there is fuel in the vessel, except when the reactor is in c.

COLD SHUTDOWN or REFUEL modes, two licensed senior reactor l

operators and two licensed reactor operators shall be on site, with at least l

one licensed senior reactor operator in the control room and one licensed reactor operator at the controls.

d.

At least two licensed reactor operators shall be in the control room during all i

reactor startups,' shutdowns, and other periods invohing planned control rod manipulations.

All CORE ALTERATIONS shall be directly supenised by either a licensed c.

l Senior Reactor Operator or Senior Reactor Operator Limited to Fuel Handling who has no other concurrent responsibilities durmg this operation.

f.

An individual quah6cd in radiation protection measures shall be on site when fuelisin the reactor.

g.

(deleted) h.

Each on duty shift shall include a ShiA Technical Achisor except that the ShiA Technical Achisors position need not be Elled ifthe reactor is in the refuel or j

shutdown mode and the reactor is less than 212 F.

i.

Administrative procedures shall be developed and implemented to limit the working hours of unit staff who perform safety related functions.

In the event that unforeseen problems require substantial amounts of owntime to be used or during extended periods of shutdown for refueling, major mamtenance or major plant modifications, on a temporary basis, the following guidelines shallbe followed:

An individual should not be pemutted to work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> a.

straight, excluding shiR tumover time.

b.

An individual should not be pemutted to work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in any 24-hour period, nor more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in any 48-hour period, nor more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> in any seven-day period, all excluding shift tumover time.

c.

A break of at least eight hours should be allowed between work period, including shift tumoser time.

d.

In a, b, and c above, the time required to complete shiA tumover is to be counted as break time and is not to be counted as work time, Except during extended shutdown periods, the use ofovertime should e.

p be considered on an individual basis and not for the entire staffon a shift.

l-OYSTER CREEK 6-2 Amendment No.: ^2, ^2,1%, ;;; 203

~

I.

\\

Any deviation from the above guidelines shall be authorized by the Department Managers, or higher levels of management, in accordance with established procedures and with documentation of the basis for grantmg the deviation.

j.

The Plant Operations Director and the Group Shift Supenisor l

require Senior Reactor Operators licenses The Control Room Operators require a Reactor Operators license.

6.2.2.3 Individuals who train the operatmg staff and those who carry out the health physics and quality assurance function shall have suf5cient organizational freedom to be mdependent of operational pressures, however, they may report to the appropriate manager on site.

6.3 Facihty StaffOmliMnns 6.3.1 Each member of the unit staff shall meet or exceed the muumum qualifications of ANSI /ANS 3.1 of 1978 for comparable positions unless otherwise noted in the Technical Specifications.

Licensed operators shall meet the supplemental requirements spect6ed in Sections A and C of of the March 28,1980 NRC letter to all licensees Technicians and mamtenance personnel who do not meet ANSI /ANS 3.1 of 1978, Section 4.5, are permitted to perform work for which quali6 cation has been inesueed.

6.3.2 1he management position responsible for radiological controls shall meet or exceed the qualifications of Regulatory Guide 1.8 (Rev.1-R,9n5). Each other member ofthe radiation protection orgamzation for which there is a comparable position described in ANSI N18.1-1971 shall meet or exceed the muumum qualifications spect6ed therein, or in the case of radiation protection technicians, they shall have at least one year's contmuous experience in applied radiation protection work in a nuclear facility deahng with radiological problems similar to those encountered in nuclear power stations and shall have beas certified by the management position responsible for radiological controls as quah6ed to perform assigned functions. This l

cenification must be based on an NRC approved, documented program consisting of classroom trauung with appropriate eununations and documented positive findings by responsible i

supenision that the individual has demonstrated his ability to perform each specified procedure and assigned function with an urnLhaiing ofits basis and purpose.

6.3.3 The Shift Technical Advisors shall have a bachelor's degree or equivalent in a scientific or engmeenng disegline with speci6c trauung in plant design, response and analysis of the plant I

for tmnsients and e*c.

I l

l l

l l

z j

OYSTER CREEK 6-2a Amendment No.:+3+.203

i 6.4 TRAINING 6.4.1 A retranung program for operators shall be maintamed under the direction of the Manager l

l responsible for plant trauung and shall meet the requirements and rewmmerdation of 10 CFR Part 55. Replacement trauung programs, the content of which shall meet the requirements of 10 CFR Part 55, shall be conducted under the direction of the Manager responsible for plant l

trauung for licensed operators and Senior Reactor Operators.

6.5 REVIEW AND AUDIT l

l 6.5.1 TECHNICAL REVIEW AND CObTfROL l

'1he Corporate Of5cers of GPU Nuclear, Inc. shall be responsible for ensuring the preparation, l

miew, and approval ofhmenta required by the actisities described in 6.5.1.1 through 6.5.1.5 within his functional area of responsibility as assigned in the GPU Nuclear Resiew and I

i Approval Matnx. Implementing approvals shall be pedormed at the cogmzant manager level or above.

ACTIVITIES 6.5.1.1 Each procedure required by Technical Specification 6.8 and other procedures which affect nuclear safety, and substantive changes thereto, shall be prepared by a designated individual (s)/ group knowledgeable in the area affected by the procedure.

Each such procedure, and substantive change thereto, shall be resientxl for adequacy 1

by an individual (s)/ group other than the preparer, but who may be from the same

[

division as the individual who prepared the procedure or change.

l l

i l

l L

i OYSTER CREEK 6-3 Amendment No.;50,78,125,04,101,;94 ?03

1 RECORDS 65.1.13 Written records of activities performed under specifications 6.5.1.1 through 6.5.1.11 l

shall be maintained OUAI IFICATIONS 6.5.1.14 Responsible Technical Resiewers shall meet or exceed the qualifications of ANSI /ANS 3.1-1978 Section 4.6 or 4.4 for applicable disciplines or have 7 years of appropriate experience in the field ofhis specialty Credit towards expenence will be given for I

advanad degrees on a one-for one basis up to a maximum of two years. These Reviewers shall be designated in wTiting.

i 6.5.2 INDEPENDENT SAFETY REVIEW FUNCTION 6.5.2.1 1he Corporate Officers of GPU Nuclear, Inc. shall be responsible for ensuring the l

periodic independent safety miew of the subjects described in 6.5.2.5 within his l

assigned area of safety miew responsibility, as assigned in the GPUN Resiew and Approsal Matnx l

6.5.2.2 Independent safety miew shall be completed by an individual / group not having direct responsibility for the performance ofthe actisities under review, but who may be from the same functionally cognizant orgamzation as the indisidual/ group perfomung the ongmal work.

6.5.2.3 GPU Nuclear, Inc. shall collectively have or have access to the experience and competence required to iw'-T-7 kly miew subjects in the following areas:

a.

Nuclear power plant operations b.

Nuclear engmeenng c.

Chenustry and rWhemistry d.

Metallurgy e.

Nondestructive testmg f.

Instmmentation and control g.

Radiological safety h.

Mechanical engmeenng i.

Electncal engmeenng j.

Admnustrative controls and quahty assurance practices

'k.

Emergency plans and related orgamzation, procedures and cquipment 1.

Other appropriate fields associated with the unique charactenstics of Oyster Creek i

6.5.2.4 Consuhants may be unhzed as determined by the cognizant Corporate Officer to provide expert advice.

OYSTER CREEK 6-5 Amendment No.: 69, 04, l';;, ;;4 203

l ;

y RESPONSIBILTTIES 6.5.2.5 The following subjects shall be independwtly rniewed by the functionally assigned divisions:

l a.

Written safety evaluations of changes in the facility as described in the Safety Analysis Report, of changes in procedures as described in the Safety Analysis Report, and of tests or experunents not described in the Safety Analysis Report, which are completed without prior NRC approval under the provisions of 10 CFR 50.59(a)(1). This review is to verify that such changes, t-sts or expenments did not involve a change in the Technical Specifications or an unresiewed safety question as defined in 10 CFR 50.59(a)(2). Such l

j rniews need not be performed prior to implementation.

b.

Proposed changes in procedures, proposed changes in the facility, or proposed tests or expenments, any of which involves a change in the Technical Specifications or an unrniewed safety question as defined in 10 CFR 50.59(c). Matters of this kind shall be resiewed prior to submittal to the NRC.

c.

Proposed changes to Technical Specifications or license ameruiments related to nuclear safety shall be rniewed prior to submittal to the NRC for approval.

i d.

Violations, deviations, and reportable events which require reporting to the NRC in writing. Such reviews are performed after the fact. Raiew of events covered under this subsection shall include results of any imestigations made and the recommendations resulting from such investigations to prn ent or reduce the probability of recurrence of the ment.

c.

Written summaries of audit reports in the areas specified in section 6.5.3 and invohing safety related functions.

f.

Any other matters invohing safe operations of the nuclear power plant which a rniewer deems appropriate for consideration, or which is referred to the mdependent raiewers.

OUALIFICATIONS 6.5.2.6 The independent reviewer (s) shall either have a Bachelor's Degree in Engmeering or the Physical Sciences and five (5) years ofprofessional lesel experience in the area being resiewed or have 9 years of appropriate experience in the field of his specialty. An individual perfomung reviews may possess competence in more than one specialty area. Credit toward experience will be given for advanced degrees on a one-for-one j

basis up to a nwamum oftwo years.

RECORDS 6.5.2.7 Reports of reviews encompassed in Section 6.5.2.5 shall be prepared, mamtamed and transmitted to the cogmzant Corporate Officer.

l OYSTER CREEK 6-6 Amendment No.: C,04 203 l

~..

RECORDS 6.5.3.3 Audit reports encompassed by sections 6.5.3.1 and 6.5.3.2 shall be forwarded for j

action to the management positions responsible for the areas audited within 30 days aAer completion of the audit. Upper management shall be informed per the Operation I

Quality Assurance Plan.

l 6.5.4 INDEPENDENT ONSITE SAFETY REVIEW GROUP GOSRG)

STRUCTURE 6.5.4.1 The IOSRG shall be a full-time group of engmeers experierad in nuclear power plant cngmeenng, operation and/or technology, mdependent of the facility staff, and located onsite.

ORGANIZATION 6.5.4.2 a.

The IOSRG shall consist of a Manager responsible for Nuclear Safety l

Assessment and staffmembers who meet the quali6 cations of 6.5.4.5. Group expertise shallbe mukidiccinlined b.

The IOSRG shall report to the Director responsible for Nuclear Safety Assessment FUNCTION 6.5.4.3 The periodic review functions of the IOSRG r. hall include the following on a selective j

and overview buis:

1)

Evaluation for technical adequacy and clarity ofprocedures important to the safe operation ofthe facihty.

2)

Evaluation of facility operations from a safety perspective.

3)

Assessment of facility nuclear safety programs 4)

Assessment of the facihty perfomance regarding conformance to requirements related to safety.

5)

Any other matter invohing safe operation of the nuclear power plant that the manager deems appropriate for consideration.

AUTHORITY 6.5.4.4 The IOSRG shall have accea to the facihty and facility records as necessary to perform its evaluations and assessments Based on its resiews, the IOSRG shall provide recommendations to the management positions responsible for the areas l

reviewed.

I i

I OYSTER CREEK 6-8 Amendment No. 6^, ;^;;, 04 203 s

' q OUALIFICATIONS L

6.5.4.5 IOSRG engmeers shall have either (1) a Bachelor's Degree in Enginerrmg or appropriate Physical Science and three years ofprofessional level everience in the

- nuclear power field which may include technical supponing functions or (2) eight years ofappropriate expenence in nuclear power plant operations and/or technology. Credit toward experience will be given for advance degrees on a one-to one basis up to a maximum oftwo Stars. '

I RECORDS 6.5.4.6 Reports ofevaluations and assessments encompassed in Section 6.5.4.3 shall be prepared, approved, and transnutted to the Director and the Corporate Officer l

responsible for nuclear safety assessment, Vice President & Director Oyster Creek, and the management positions responsible for the areas resiewed.

6.6 REPORTABLE EVENT ACTION 6.6.1

'Ihe following actions shM1 be taken for REPORTABLE EVENTS:

The Commission shall be notified and a repon subnutted pursuant to the requirements a.

of Section 50.73 to 10 CFR Part 50;and b.

Each REPORTABLE EVENT shall be reported to the cogmzant manager and the cogmzant division Vice President and the Vice President & Director Oyster Creek.

  • lle functionally cogmzant division staff shall prepare a Licensee Event Report (LER) in accordance with the guidance outhned in 10 CFR 50.73(b). Copies ofall such reports shall be subnutted to the functionally cogmzant Corporate OfEcer and the Vice President & Director Oyster Creek.

6.7 SAFETY LIMIT VIOLATION 6.7.1 The following actions shall be taken in the event a Safety Limit is violated:

If any Safety Limit is exceeded, the reactor shall be shut dosm immediately until the a.

Commission authorizes the resumption ofoperation.

b.

The Safety Limit violation shall be reported to the Commission and the Vice President l

and Director Oyster Creek.

A Safety Limit Violation Report shall be prepared. The report shall be submitted to c.

the Vice President and Director Oyster Creek. 'Ihis report shall descnte (1) applicable circumstances precedmg the violation, (2) effects of the siolation upon facility components systems or structures, (3) corrective action taken to prevent recurrence d.

The Safety Limit Violation Report shall be submitted to the Comnussion within ten days ofthe violation.

i OYSTER CREEK 6-9 Amendment No.: '9, 73, 34, i 17,134 203 l