_ _ _ _
~
.. t M 3 0 se?
[
YEMORANDUM FOR:
Robert A. Capra, Project Director DISTRIBUTION Project Directorate I.1 JocketaFfle Division of Reactor Projects I, !!
SRXB R/F
/
FROM:
Marvin W. Hodges, Chief
/
RJones WHodges Reactor Systems Branch GTHomas Division of Engineering & Safety Technology GThomas R/F SRXB Members
SUBJECT:
NINE MILE POINT UNIT 2 - REPLACEMENT OF MSIV BALL VALVES WITH WYE PATTERN GLOBE VALVES Plant Name:
Nine Mlle Point Nuclear Station. Unit 2 Docket No.:
50 410 Licensing Status:
OL Project Directorate:
Project Directorate I-l Project Manager Mary Haughey Review Branch:
SRXB Review Status:
Complete Tac No.:
64871 The Reactor Systems Branch has reviewed the Niagara Mohawk Power Corporation's submittal regarding the MS!V change from hydraulic actuated ball valves to air operated Wye-pattern globe valves and the associated Techniccl Specifications changes fnr the MSIV. closure trip setpoints.
The new valves will close in 3 5 seconds in accordance with the present limits ghen in the technical specifications.
The new valves are actuated on the same safety related signals as previously described in the FSAR. The MSIV change has no significant effect en any transient or accident analysis.
- Thus, we find the MSIV change acceptable. is our evaluation of the licensee's submittal.
Enclosure-? is our SALP input, er%W si ned ty t
0705080037 m OO MaMm g
ADocK 05000410 Marvin W. Hodges Chief Reactor Systems Branch Division of Engineering & Systems Technology Enciesures: As stated cc w/ enclosures:
W,3&o S. Varga B. Boger A. Thadant M. Haughey D. J. Neighburs SRXB Merbers
Contact:
G. Thomas /SRXB/x27588 0FC :SRXBi
- 5RXB:0EST / :5RXB: DEST
..... :... (/.,U 5 Th......:......f':........... (.'...........:............:............::...........
NAME :GT40 MAS:jh :RJONES
- WHODGES t
.....:............:..........[..:.......$(.W...:.
l
</ d/87 4/M/87 DATE : 4/y(87 i
OtrICTADMED COPL__~
(_ _f& h k$