ML20189A079

From kanterella
Jump to navigation Jump to search
8 to Updated Final Safety Analysis Report, Chapter 4, Appendix 4B, Figures
ML20189A079
Person / Time
Site: Oconee  
(DPR-038, DPR-047, DPR-055)
Issue date: 06/29/2020
From:
Duke Energy Carolinas
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20189A066 List:
References
RA-20-0136
Download: ML20189A079 (36)


Text

Oconee Nuclear Station UFSAR Appendix 4B. Figures Appendix 4B. Figures

Oconee Nuclear Station UFSAR Figure 4-1 (Page 1 of 1)

(31 DEC 2000)

Figure 4-1. Burnable Poison Rod Assembly

Oconee Nuclear Station UFSAR Figure 4-2 and 4-3 (Page 1 of 1)

(31 DEC 2000)

Figure 4-2. Deleted Per 1999 Update Figure 4-3. Deleted Per 1999 Update

Oconee Nuclear Station UFSAR Figure 4-4 (Page 1 of 1)

(31 DEC 2000)

Figure 4-4. Typical Pressurized Fuel Rod

Oconee Nuclear Station UFSAR Figure 4-5 (Page 1 of 1)

(31 DEC 2012)

Figure 4-5. Typical Boron Concentration Versus Core Life Note: Square data points represent 18 month cycles and diamonds represent 24 month cycles

Oconee Nuclear Station UFSAR Figure 4-6 (Page 1 of 1)

(31 DEC 2012)

Figure 4-6. Typical BPRA Concentration and Distribution

[HISTORICAL INFORMATION BELOW NOT REQUIRED TO BE REVISED.]

Oconee Nuclear Station UFSAR Figure 4-7 (Page 1 of 1)

(31 DEC 2000)

Figure 4-7. Typical Control Rod Locations and Groupings

Oconee Nuclear Station UFSAR Figure 4-8 (Page 1 of 1)

(31 DEC 2000)

Figure 4-8. Typical Uniform Void Coefficient

Oconee Nuclear Station UFSAR Figure 4-9 (Page 1 of 1)

(31 DEC 2000)

Figure 4-9. Deleted per 1995 Update

Oconee Nuclear Station UFSAR Figure 4-10 (Page 1 of 1)

(31 DEC 2000)

Figure 4-10. Typical Rod Worth Versus Distance Withdrawn

Oconee Nuclear Station UFSAR Figure 4-11 (Page 1 of 1)

(31 DEC 2000)

Figure 4-11. Percent Neutron Power Versus Time Following Trip

Oconee Nuclear Station UFSAR Figure 4-12 (Page 1 of 1)

(31 DEC 2000)

Figure 4-12. Power Spike Factor Due to Fuel Densification

Oconee Nuclear Station UFSAR Figure 4-13 (Page 1 of 1)

(31 DEC 2000)

Figure 4-13. Power Peaking Caused by Dropped Rod (Oconee Unit 1, Cycle 1)

Oconee Nuclear Station UFSAR Figure 4-14 (Page 1 of 1)

(31 DEC 2000)

Figure 4-14. Azimuthal Stability Index Versus Moderator Coefficient From Three Dimensional Case (Oconee Unit 1, Cycle 1)

Oconee Nuclear Station UFSAR Figure 4-15 (Page 1 of 1)

(31 DEC 2000)

Figure 4-15. Azimuthal Stability Index with Compounded Error Versus Moderator Coefficient Calculated From Three Dimensional Case (Oconee Unit 1, Cycle 1)

Oconee Nuclear Station UFSAR Figure 4-16 (Page 1 of 1)

(31 DEC 2000)

Figure 4-16. Azimuthal Stability Index Versus Moderator Coefficient From Three Dimension Case (Oconee Unit 2, Cycle 1)

Oconee Nuclear Station UFSAR Figure 4-17 (Page 1 of 1)

(31 DEC 2000)

Figure 4-17. Azimuthal Stability Index with Compounded Error Versus Moderator Coefficient From Three Dimensional Case (Oconee Unit 2, Cycle 1)

Oconee Nuclear Station UFSAR Figure 4-18 (Page 1 of 1)

(31 DEC 2000)

Figure 4-18. Deleted per 1997 Update

Oconee Nuclear Station UFSAR Figure 4-19 and 4-20 (Page 1 of 1)

(31 DEC 2000)

Figure 4-19. Deleted Per 1995 Update Figure 4-20. Deleted Per 1995 Update

Oconee Nuclear Station UFSAR Figure 4-21 (Page 1 of 1)

(31 DEC 2000)

Figure 4-21. Flow Regime Map for the Hot Unit Cell

Oconee Nuclear Station UFSAR Figure 4-22 (Page 1 of 1)

(31 DEC 2000)

Figure 4-22. Flow Regime Map for the Hot Control Rod Cell

Oconee Nuclear Station UFSAR Figure 4-23 (Page 1 of 1)

(31 DEC 2000)

Figure 4-23. Flow Regime Map for the Hot Wall Cell

Oconee Nuclear Station UFSAR Figure 4-24 (Page 1 of 1)

(31 DEC 2000)

Figure 4-24. Flow Regime Map for the Hot Corner Cell

Oconee Nuclear Station UFSAR Figure 4-25 (Page 1 of 1)

(31 DEC 2000)

Figure 4-25. Deleted Per 1996 Update

Oconee Nuclear Station UFSAR Figure 4-26 (Page 1 of 1)

(31 DEC 2000)

Figure 4-26. Reactor Vessel and Internals General Arrangement

Oconee Nuclear Station UFSAR Figure 4-27 (Page 1 of 1)

(31 DEC 2000)

Figure 4-27. Reactor Vessel and Internals Cross Section

Oconee Nuclear Station UFSAR Figure 4-28 (Page 1 of 1)

(31 DEC 2000)

Figure 4-28. Core Flooding Arrangement

Oconee Nuclear Station UFSAR Figure 4-29 (Page 1 of 1)

(31 DEC 2000)

Figure 4-29. Internals Vent Valve Clearance Gaps

Oconee Nuclear Station UFSAR Figure 4-30 (Page 1 of 1)

(31 DEC 2000)

Figure 4-30. Internals Vent Valve

Oconee Nuclear Station UFSAR Figure 4-31 (Page 1 of 1)

(31 DEC 2000)

Figure 4-31. Control Rod Assembly

Oconee Nuclear Station UFSAR Figure 4-32 (Page 1 of 1)

(31 DEC 2000)

Figure 4-32. Axial Power Shaping Rod Assembly

Oconee Nuclear Station UFSAR Figure 4-33 (Page 1 of 1)

(31 DEC 2000)

Figure 4-33. Deleted Per 1999 Update

Oconee Nuclear Station UFSAR Figure 4-34 (Page 1 of 1)

(31 DEC 2000)

Figure 4-34. Control Rod Drive - General Arrangement

Oconee Nuclear Station UFSAR Figure 4-35 and 4-36 (Page 1 of 1)

(31 DEC 2000)

Figure 4-35. Deleted Per 1999 Update Figure 4-36. Deleted Per 1999 Update

Oconee Nuclear Station UFSAR Figure 4-37 (Page 1 of 1)

(31 DEC 2000)

Figure 4-37. Typical Fuel Assembly

Oconee Nuclear Station UFSAR Figure 4-38 (Page 1 of 1)

(31 DEC 2004)

Figure 4-38. Westinghouse 177 Fuel Assembly