DEC 191973 Docket Nos.

50-416/417 R. C. DeYoung, Assistant Director for Light Water Reactors Group 1, L DRAFI SAFETY EVALUATION REPORT - CONTAINMENT SYSTEMS - GRAND GULF NUCLEAR STATION, UNITS 1 & 2 Plant Name:

Grand Gulf, Units 1 & 2 Docket Nos.:

50-416/417 Licensing Stage:

CP NSSS Supplier:

General Electric Architect Engineer:

Bechtel Containment Type: Mark III Responsible Branch & Project Manager:

LWR #1-2; G. Owsley Requested Completion Date: December 10, 1973 Applicant's Response Date:

N/S Review Status:

Incomplete Enclosed is the draft Safety Evaluation Report from the Containment Systems Branch for the Grand Gulf Nuclear Station, Units 1 & 2.

Our review is based on the applicable sections of the PSAR and Amendments 1 through 16.

As noted in' the enclosed draf t Safety Evaluation, the following items are identified as requiring resolution that is expected to occur prior to issuance of the construction per=it and will be reported in a supplement to the Safety Evaluation.

1.

Our consultants (ANC) have advised us that the reactor blowdown rates used by GE in calculating the Mark III containment pressure response may not be conservative with respect to predicting short-term blowdown rates; i.e., less than one second.

Consequently, we cannot conclude on the adequacy of the drywell and subcompartment design pressures at this time.

We' plan to meet with the applicant and GE to discuss this matter which could ultimately result in our requiring larger margins than the proposed 30%.

(Section 6. 2.1. 2 and 6. 2.1. 5) 2.

The currently proposed design of the containment spray system needs to be modified as discussed with GE.

We have met with GE on a generic basis and believe that proposed modifications will result in an acceptable system; i.e., the RHR pumps presently used for both ECCS and containment spray be automatically actuated for 8906160261 880606 PDR FOIA CONNOR 88-91 PDR V

C 0

R. C. DeYoung DEC 1 9 IES

]

o containment spray at 10 minutes following the ace!. dent.

This approach appears acceptable to us; however, we are awaiting receipt of design aspects for this modification.

Pending receipt of this informatio'n, and completion of our review we will address this mitter in a supplement.

(Section 6.2.1.6) 3.

The applicant has been advised that a full-pressure leakage test of the drywell must be performed prior to plant start-up and that low pressure leakage tests must be performed periodically thereafter.

The applicant needs to discuss the detaile of this testing.

(Section 6.2.1.6) 4.

The design of the secondary containment and associated systems is not complete at this time.

The applicant has stated that this information will be submitted in a future amendment.

(Section 6.2.3) 5.

The proposed design of the drywell vacuum relief system is not acceptable; i.e.,

the absence of diversity for isolation.

Either check valves should be installed in each of the vacuum relief lines or an equivalent means to prevent inadvertent bypassing of the suppression pool.

This matter will be reviewed in conjunction with EICSB.

(Section 6.2.1.3) 6.

We will require automatic actuatien of the h;drogen re-circulation system.

The initiation mode and associated interlocks have not been resolved.

This matter will be reviewed with EICSB.

(Section 6.2.5) 7.

GE has promised us additional information concerning a detailed description and schedule of the ongoing test program, effects of non-uniform pressure loads and a historical su= mary on pressure suppression testing and development.

This information is due on or about December 21, 1973.

In addition, the mechanical forces,that may be generated by pool dynamics have not been covered by us.

The Engineering group should review this design area.

(Section 6.2.1.2)

The full-scale Mark III test program is not complete at this time.

We believe that our review for purposes of a construction permit is

e 3-g ig g$

R. C. DeYoung i

reasonably complete without these test data; however, Item 1 above cust be resolved at this time. We plan to continue our review of the test program and results as an ongoing effort generic to the Mark III concept.

Y km Robert L. Tedesco, Assistant Director for Containment Safety Directorate of Licensing

Enclosure:

As stated cci w/o encl.