-0UAD CITIES NUCLEAR POWER STATION RADI0 ACTIVE WASTE AND ENVIRONMENTAL MONITORING l

1

' ANNUAL REPORT 1987 1

(

i APRIL 1988

/

(

/

t 8905060299 871231

{DR ADOCK 05000254 DCD

~w

s TABLE OF CONTENTS Page INTRODUCTION 1

SUMMARY

2 1.0 EFFLUENTS 1.1 Gaseous 3

1.2 Liquid............................

3 2.0 SOLID RADI0 ACTIVE WASTE......................

3 3.0 DOSE TO MAN 3.1 Gaseous Effluent Pathways 3

3.2 Liquid Effluent Pathways...................

5 4.0 SITE METEOROLOGY 5

5.0 ENVIRONMENTAL MONITORING 5

5.1 Gamma Radiation 6

5.2 Airborne I-131 and Particulate Radioactivity.........

6 6

5.3 Aquatic Radioactivity 5.4 Milk.............................

7 7

5.5 Sample Collection 7

5.6 Special Collections 6.0 ANALYTICAL PROCEDURES.......................

7 7.0 MILCH ANIMAL CENSUS........................

7 l

8.0 NEAREST RESIDENT CENSUS......................

8 9.0 INTERLABORATORY COMPARISON PROGRAM RESULTS 8

APPENDIX I - DATA TABLES AND FIGURES..................

31 Station Releases Table 1.1-1 Gaseous Effluents 32 Table 1.2-1 Liquid Effluents...................

42 46 Table 2.0-1 Solid Waste Shipments iii

m.

n-y TA8LE OF CONTENTS (continued)

Page APPENDIX I - DATA TABLES AND FIGURES StationReleases(continued)

Figure 3.1 Figure 3.1-4 Isodose and Concentration Contours..........

58 Table 3.1-1 Maximum Doses Resulting from Airborne Releases....

62 Table 3.2-1 Maximum Doses Resulting from Liquid Discharges....

64 Environmental Monitoring Figure 5.0 Figure 5.0-3 Locations of Fixed Environmental P.adiological Stations......................

66 Table 5.0-1 Standard Radiological Sampling Program........

69 Table 5.0-2 Environmental Radiological Monitoring Program 70

-Table 5.0 Table 5.0-6 Environmental Sumary Tables.............

77 Table 5.1-1 Gama Radiation Measurements (TLD)..........

81 APPENDIX II - METEOROLOGICAL DATA 84 APPENDIX III - LISTING 0F MISSED SAMPLES................

113 iv

1

?

INTRODUCTION Units 1 and 2 of the Quad Cities Station located near Cordova, Illinois next to the Mississippi River, are 800 MWe boiling water reactors, similar in design to Dresden Units 2 and 3.

The plant has been designed to keep releases to the environment at levels below those specified in the regulations.

Liquid effluents from Quad Cities are released to the Mississippi River in controlled batches af ter radioassay of each batch.

Gaseous effluents are released to the atmosphere af ter delay to permit decay of short half-life gases.

Releases to the atmosphere are calculated on the basis of analyses of daily grab samples of noble gases and continuously collected composite samples of iodine and particulate matter.

The results of effluent analyses are sumarized on a monthly basis and reported to the Nuclear Regulatory Comission as required per Technical Specifications.

Airborne concentrations of noble gases, I-131 and particulate radioactivity in off-site areas are calculated using effluent and meteorological data on isotopic composition of effluents.

Environmental monitoring is conducted by sampling at indicator and reference (background) locations in the vicinity of the Quad Cities plant to measure changes in radiation or radioactivity levels that may be attributable to plant operations. If significant changes attributable to Quad Cities are measured, these changes are correlated with effluent releases.

External gama radiation exposure from no'cle gases and I-131 in milk are the most critical pathways at this site; however, an environmental monitoring program is conducted which includes other pathways of less importance.

l 1

r -

SUP"4ARY Gaseous and liquid effluents for the period re,nained at a fraction-of the Technical Specification limits.

Calculations of environmental concentrations based on effluent, Mississippi River flow, and meteorological data for the period indicate that consumption by the public of radionuclides attributable to ~ the plant are unlikely to exceed the regulatory limits.

Gamma radiation exposure from noble gases released to the atmosphere represented the critical pathway for the period with a maximum individual dose estimated to be 0.0046 mrem for the year, when a shielding and occupancy factor of 0.7 is assumed.

The assessment of radiation doses are performed in accordance with the Off-Site Dose Calculation Manual (00CM).

The results of analysis confirm that the station is operating in compliance with 10CFR50 Appendix I and 40 CFR 190.

l

\\

N 2

t

-1.0 EFFLUENTS 1.1 Gaseous Effluents to the Atmosphere Measured concentrations and isotopic composition of noble gases, radioiodine, and particulate radioactivity releasect to the atmos-phere - duri ng the year, are listed i n T a b l e 1.1 -1.

A total of 3.73E+02 curies of fission and activation gases was released with an average release rate of 1.19E+01 pCi/sec.

A tetal of 1.45E-02 curies of I-131 was released during the year, witn an average release rate of 4.60E-04 pCi/sec.

A total of 7.94E-02 curies of beta-gamma emitters and 2.26E-05 curies of alpha emitters was released as airborne particulate matter, with an average release rate of 2.52E-03 pCi;sec.

A total of 93.9 curies of tritium was' released, with an average release rate of 2.99 pCi/sec.

1.2 Liquids Released to the Mississippi A total of 3.34E+06 liters of radioactive liquid waste (prior to dilution) containing 7.10E-02 curies (excluding tritium, gases, and alpna) were discharged af ter dilution with a total of 2.36E+ ; liters of water.

These wastes were released at a quarterly average con-centration of 1.87E-09 pCi/ml during the first ard second quarters, dicharged on an unidentified nuclide basis; and 5.78E09 pCi/ml during the third and fourth quarters.

A total o' 6.53E 05 curies of alpha radioactivity and 6.92 curies of tritium were released.

Quarterly release estimates and principal radionuclides in liquid effluents are given in Table 1.2-1, 2.0 SOLID RADI0 ACTIVE WASTE Solid radioactive wastes were shipped tr U. S. Ecology, Barnwell Nuclear Center, South Carolina, Chem Nuclear OL. and Scientific Ecology Group.

The record of waste shipments is sumarizet m Table 2.0-1.

3.0 DOSE TO MAN 3.1 Gaseous Effluent Pathways Gr.mma Dose Rates Gama air and whole body dose rates off-site were calculated based on measured release rates, isotopic composition of the noble gases, and meteorological data for the period (Table 3.1-1).

Isodose 3

0 _

k contours of whole body dose are shown in Figure 3.1-1 for the year.

Based on measured effluents and meteorological data, the maximum dose to an individual would be 0.0046 mrem for the year, with an occupancy or shielding factor of 0.7 inclu;ed.

The maximum gama air dose was 0.0093 mrad.

Beta Air and Skin Rates The range of beta particles in air is relatively small (on the order of a few meters or less): consequently, plumes of gaseous effluents may be considered "infinite" for purpose of calculating the dose from beta radiation incident on the skin.

However, the actual dose to sensitive skin tissues is difficult to calculate because this depends on the beta particle energies, thickness of inert skin, and clothing covering sensitive tissuet.

For purposes of this report the skin is taken ta have a thickness of 7 mg/cm2 and an occupancy factor of 1.0 is used.

The skin dose from beta and gama radiation for the year was 0.013 mrem.

The air concentrations of radioactive noble gases at the off-site receptor locatior.s are given in Figure 3.1-2.

The max '

  • off-site beta air dose for the year was 0.0085 mrad.

Radioactive Iodine The human thyroid exhibits a significant capacity to concentrate ingested or inhaled iodine, and the radioiodine, 1-131, released during routine operation of the plant, may be made available to man thus resulting in a dose to the thyroid.

The principal pathway of interest for this radionuclide is ingestion of radioiodine in milk by an infant.

Calculation made in previous years indicate that contributions to doses from inhalation of I-131 and I-133, and I-133 in milk are negligible.

Iodine-131 Concentrations in Air The calculated concentration contours for I-131 in air are shown in Figure 3.1-3.

Included in these calculations is an iodine cloud depletion facta which accounts for the phenomenon of elemental lodine deposition on the ground.

The maximum off-site average concentration is estimated to be 1.41E-03 pCi/m3 for the year.

Dose to Infant's Thyroid The hypothetical thyroid dose to an infant living near the plant via ingestion of milk was calculated.

The radionuclide considered was I-131 and the source of milk was taken to be the nearest dairy farm with the cows pastured from May to October.

The maximum infant's thyroid dose was 0.19 mrem during the year (Table 3.1-1).

4 m

-c.---

6 Concentrations of Particulates in Air Concentration contours of radioactive airborne particulates are shown in Figure 3.1-4.

The maximum off-site average level is estimated to be 3.57E-03 pCi/m3 Summary of Doses Table 3.1-1 summarizes the doses resulting from releases of airborne radioactivity via the different exposure pathways.

3.2 Liquid Effluent Pathways The three principal pathways through the aquatic environment for potential doses to man from liquid waste are ingestion of potable water, eating aquatic foods, and exposure while walking on the shore-line.

Not all of these pathways are applicable at a given time or station but a reasonable approximation of the dose can be made by adjusting the dose formula for season of the year or type and degree of use of the aquatic environment.

NRC* developed equations were used to calculate the doses to the whole body, lower GI tract, thyroid, bone and skin; specific parameters for use in the equations are given in the Comonwealth Edison Off-site Dose Calculation Manual.

The maximum whole body dose for the year was 0.0028 mrem and no organ dose exceeded 0.0042 mrem.

4.0 SITE METEOROLOGY A summary of the site meteorological measurements taken during each quarter of the year is given in Appendix II.

The data are presented as cumulative joint frequency distributions of 296' level wind direction and wind speed class by atmospheric stability class determined from the temperature difference between the 296' and 33' levels.

Data recovery for all measure-ments on the tower was about 97.8%.

5.0 ENVIRONMENTAL MONITORING l

Tables 5.0-1 and 5.0-2 provide an outline of the radiological environmental monitoring program as required in current Technical Specifications.

This program went into effect in November 1977 and differs from previous programs in the number and types of analyses performed.

Tables 5.0-3 to 5.0-3 to 5.0-6 sumarize data for the year.

Except for tables of special interest, tables listing all data are no longer included in the annual report. All data tables are available for inspection at the Station or in the Corporate offices.

Specific findings for various environmental media are discussed in Sections 5.1 through 5.5.

5

_g 5.1 Gama Radiation External radiation dose from on-site sources and noble gases released to the atmosphere was measured at six indicator and ten reference (background) locations using solid lithium fluoride thermoluminescent dosimeters (TLD).

A comparison of the TLD results for reference stations with on-site and off-site indicator stations is included in Table 5.1-1.-

A total of 61 additional TLDs were installed on June 1, 1980 such that each sector was covered at both five miles and the site boundary.

Locations of the TL0s are shown in Figures 5.0-1 and 5.0-2.

5.2 Airborne I-131 and Particulate Radioactivity Concentrations of airborne I-131 and particulate radioactivity at monitoring locations are sumarized in Tables 5.0-3 through 5.0-6.

Locations of the samplers are shown in Figure 5.0-1.

Airborne I-131 remained below the LLO of 0.10 pC1/m3 throughout the year.

Gross beta concentrations ranged from 0.009 to 0.048 pCi/m3 and averaged 0.024 pCi/md.

No radioactivity attributable to plant operation was detected in any sample.

5.3 Aquatic Radioactivity Surface water samples were collected daily and composited for analysis weekly from the Inlet Canal, Blowdown Diffuser Pipe, East Moline Water Works, and Davenport Water Works.

The cooling water samples were analyzed weekly for gross beta concentrations.

A composite sample from each quarter from the blowdown diffuser pipe did not indicate measurable radioactivity attributable to station operation.

Annual mean gross beta concentraton in the blowdown diffuser and inlet canal pipe water samples was identical (3.5 pCi/1).

Tritium was detected in one quarterly composite (1st quarter) and measured 622 pCi/1.

Samples from the two water works were composited monthly and analyzed for gama emitters.

All samples analyzed were below the limits of detection for the program indicating that there was no measurable amount of radioactivity due to station operation present.

Levels of gama radioactivity in fish were measured and found in all cases to be below the lower limits of detection for the program.

A sediment sample was analyzed by gama spectrometry.

Gama-emitters were either below the limits of detection or at the level usually encountered in the environment (Cs-137, 0.12 pCi/g dry weight) indicating the presence of no radioactivity due to station operation.

6

t 5.4 Milk Milk samples were collected monthly from November through Apr'1 and weekly from May through October and analyzed for Iodine-131.

Sampled locations were the Hansen Dairy Farm located about 6.0 miles northeast of the Station, and Musal Dairy Farm located 5.5 miles southwest of the Station, both being the closest dairies ts the station.

1-131 remained below the detection limits of 5.0 pCi/l during the non-period (November to April) and 0.5 pCi/l during the grazing grazing (May to October).

period 5.5 Sample Collections All samples were collected as scheduled except those listed in Listing of Missed Samples, Appendix III.

5.6 Special Collections No special collections were made during the period.

6.0, ANALYTICAL PROCEDURES A summary of the procedures used for analyzing radioactivity in the environmental samples is given in Appendix III of the report for the period Janaury - December 1985.

Procedures used during the period covered by this report remained essentially unchanged.

7.0 MILCH ANIMAL CENSUS A census of milch animals was conducted within five miles of the Station.

The survey conducted by "door-to-door" ct2nvas and by ir4 formation from Illinois and Iowa Agricultural Agents.

The census was conducted by G. Kreuder on August 17, 1987.

There were no dairy farms within a five mile radius of the Quad Cities Nuclear Power Station.

The findings of the survey follow, iithin2MilesofthePlant Norer Within 2 - 6 Miles of the Plant Illinois

  • Mel Hansen (Jeff)

Albany, IL (309) 887-4568 6.0 miles NE -- Type:

Holstein Number:

50 Feed:

Alfalfa haylage, corn silage, shelled corn l

7

-w _.

=

J Iowa. --- Alan Musal, Rural Route, Princeton, Iowa (319) 289-4786 5-1/2 miles SW -- Type:

Holstein Number:

80 Feed:

Alfalfa haylage, corn silage, shelled corn 8.0 NEAREST RESIDENT CENSUS A census of the nearest residences within a five (5) mile radius was conducted. on August 17, 1987 by G. Kreuder.

Tne location of residences remained unchanged from.the previous census.

The nearest residences are listed below.

Direction Distance N

0.6 miles NNE 1.0 miles NE 1.3 miles ENE 2.8 miles E

2.3 miles ESE 2.0 miles SE 1.0 miles SSE 1.1 miles S

0.8 miles SSW 3.0 miles SW 2.8 miles WSW 2.0 miles W

2.5 miles WNW 2.5 miles NW 2.0 miles NNW 2.0 miles 9.0 INTERLABORATORY COMPARISON PROGRAM RESULTS Teledyne Isotopes Midwest Laboratory (formerly Hazleton Environmental Sciences) has participated in interlaboratory comparison (crosscheck) programs since the formulation of its quality control program in December 1971.

These programs are operated by agencies which supply environmental-type samples (e.g., milk or water) containing concentrations of radio-nuclides known to the issuing agency but not to participant laboratories.

The purpose of such a program is to provide an independent check on the laboratory's analytical procedures and to alert it ot any possible probl ems.

8

t Participant laboratories measure the concentrations of specified radio-nuclides and report them to the issuing agency.

Several months later, the agency reports the known values to the participant laboratories and specifies control limits.

Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used.

The results in Table A-1 were obtained through participation in the environmental sample crosscheck program for milk, water, air filters, and food samples during the period May 1984 through December 1987.

This program nas been conducted by the U. S. Environmental Protection Agency Intercomparison and Calibration Section, Quality Assurance Branch, a

Environmental Monitoring and Support Laboratory, Las Vegas, Nevada.

The results in Table A-2 were obtained for thermoluminescent dosimeters (TL0s) during the period 1976, 1977, 1979, 1980, 1984 and 1985-1986 through participation in the Second, Third, Fourth, Fifth, Seventh, and Eighth International Intercomparisons of Environmental Dosimeters under the sponsorships listed in Table A-2.

Table A-3 lists results of the analyses on in-house spiked samples.

Table A-4 lists results of the analyses on in-house "blank" samples.

Attachment B lists acceptance criteria for "spiked" samples.

l i

i i

l l

9

5 Table A-1.

U.S. Environmental Protection Agency's crosscheck program, com-parison of EPA and Teledyne Isotopes Midwest Laboratory results for milk, water, air filters, and food samples,1984 through 1987.a Concentration in pCi/lb Lab Sample Date TIML Result EPA Resultd Code Type Collec ted Analysis 120c Is, N=1 Control Limits STW-358 Water May 1984 Gr. alpha 3.010.6 315.0 0.0-11.7 Gr. beta 6.711.2 625.0 0.0-14.7 STM-366 Milk June 1984 Sr-89 21*3.1 25t5.0 16.3-33.7 Sr-90 13t2.0 17tl. 5 14,4-19.6 I-131 4615.3 4316.0 32.6-53.4 Cs-137 3814.0 3515.0 26.3-43.7 K

15771172 1496 75 1336-1626 STW-368 Water July 1984 Gr. alpha 5.111.1 615.0 0.0-14.7 Gr. beta

11. 9i2.4 13t5.0 4.3-21.7 STW-369 Water August 1984 1-131 34.315.0 34.0f6.0 23.6-44.4 STW-370 Water August 1984 H-3 30031253 2817A356 2200-3434 STF-371 Food July 1984 Sr-89 22.0i5.3 25.015.0 14.3-33.7 Sr-90 14.7i3.1 20.011.5 17.4-22.6 I-131

<172 39.0i6.0 28.6-49.4 Cs-137 24.0i5.3 25.015.0 14.3-33.7 K

25031132 26051130 2379-2831 STAF-372 Air August 1984 Gr. alpha 15.311.2 1715.0 8.3-25.7 Filter Gr. beta 56.010.0 5115.0 42.3-59.7 Sr-90 14.311.2 18tl.5 15.6-20.4 Cs-137

21. 0t2. 0 15i5.0 6.3-23.7 STW-375 Water Sept 1984 Ra-226 5.110.4 4.910.7 3.6-6.2 Ra-228 2.210.1 2.310.4 1.7-2.9 STW-377 Water Sept 1984 Gr. alpha 3.311.2 5.015.0 0.0-13.7 Gr. beta 12.712.3 16.015.0 7.3-24.7 STW-379 Water Oct 1984 H-3 28601312 28101205 2454-3166 STW-380 Water Oct 1984 Cr-51

<36 40i5.0 31.3-48.7 Co-60 20.311.2 2015.0 11.3-28.7 Zn-65 15018.1 14715.0 138.3-155.7 Ru-106

<30 4715.0 36.3-55.7 Cs-134 31.317.0 3115.0 22.3-39.7 Cs-137 26.711.2 2415.0 15.3-32.7 10

4 Table A-1.

(continued)

Concentration in pCi/lb Lab Sample Date TIML Result EPA Resultd Code Type Coll ected Analysis 12cc Is, N=1 Control Limits STM-382 Milk Oct 1984 Sr-09 15.714.2 2215.0 13.3-30.7 Sr-90 12.711.2 1611.5 13.4-18.6 1-131 41.7t3.1 4216.0 31.6-42.4 Cs-137 31.3t6.1 3215.0 23.3-40.7 K

1447166 1517176 1386-1648 STW-384 Water Oct 1984 Gr. alpha 9.711.2 1415.0 5.3-22.7 (Blind)

Sample A Ra-226 3.310.2 3.010.5 2.2-3.8 Ra-228 3.411.6 2.110.3 1.6-2.6 Uranium nae 0.0-15.4 Sample B Gr. beta 48.3 5.0 6415.0 55.3-72.7 Sr-89 10.714.6 1115.0 2.3-19.7 Sr-90 7.311.2 12il.5 9.4-14.6 Co-60 16.311.2 1415.0 5.3-22.7 Cs-134

<2 215.0 0.0-10.7 Cs-137 16.711.2 1415.0 5.3-22.7 STAF-387 Air Nov 1984 Gr. alpha 18.711.2 1515.0 6.3-23.7 Filter Gr. beta 59.015.3 5215.0 43.3-60.7 Sr-90 18.311.2 2111.5 18.4-23.6 Cs-137 10.3i1.2 1015.0 1.3-18.7 STW-388 Water Dec 1984 1-131 28.012.0 3616.0 25.6-36.4 STW-389 Water Dec 1984 H-3 35831110 31821360 2558-3806 STW-391 Water Dec 1984 Ra-226 8.411.7 8.6i1.3 6.4-10.8 Ra-228 3.110.2 4.lf0.6 3.0-5.2 l

j STW-392 Water Jan 1985 Sr-89

<3.0 3.015.0 0.0-11.7 Sr-90 27.315.2 30.011.5 27.4-32.6 STW-393 Water Jan 1985 Gr. alpha 3.311.2 515.0 0.0-13.7 Gr. beta 17.313.0 1515.0 6.3-23.7 STF-395 Food Jan 1985 Gr. alpha 4.712.3 6.015.0 0.0-14.7 Gr. beta 11.311.2 15.015.0 6.3-23.7 Sr-89 25.316.4 34.0i5.0 25.3-42.8 Sr-90 27.018.8 26.011.5 23.4-28.6 1-131 38.012.0 35.016.0 24.6-45.4 Cs-137 32.7t2.4 29.015.0 20.3-37.7 K

14101212 1382f120

  • 1174-1590 11

o Table A-1.

(continued)

Concentration in pCi/10 Lab Sample Date TIML Result EPA Resultd Code Type Coll ec ted Analysis 22ac Is, N=1 Control Limits STW-397 Water Feb 1985 Cr-51

<29 48i5.0 39.3-56.7 Co-60 21.313.0 20t5.0 11.3-28.7 Zn-65 53.715.0 55f5.0 46.3-63.7 Ru-106

<23 25t5.0 16.3-33.7 Cs-134 32.3tl.2 3515.0 26.3-43.7 Cs-137 25.313.0 25i5.0 16.3-33.7 STW-398 Water Feb 1985 H-3 3869 319 37961634 3162-4430 STM-400 Milk March 1985 1-131 7.312.4 9.010.9 7.4-10.6 STW-402 Water March 1985 Ra-226 4.610.6 5.010.8 3.7-6.3 Ra-228

<0.8 9.011.4 6.7-11.3 Reanalysis Ra-228 9.010.4 STW-404 Water March 1985 Gr. alpha 4.7i2.3 615.0 0.0-14.7 Gr. beta 11.3*1.2 1515.0 6.3-23.7 STAF-405 Air March 1985 Gr. alpha 9.3i1.0 10.015.0 1.3-18.7 Filter Gr. beta 42.011.1 36.015.0 27.3-44.7 Sr-90 13.3tl.0 15.011.5 12.4-17.6 Cs-137 6.311.0 6.015.0 0.0-14.7 STW-407 Water April 1985 I-131 8.010.0 7.510.8 6.2-8.8 STW-408 Water April 1985 H-3 3399t150 3559t630 2929-4189 STW-409 Water April 1985 (Blind)

Gr. alpha 29.7tl.8 32.0i5.0 23.3-40.7 Sample A Ra-226 4.4i0.2 4.110.6 3.1-5.1 Ra-228 nae 6.210.9 4.6-7.8 Uranium nae 7.0i6.0 0.0-17.4 Sample B Gr. beta 74.3111.8 72.0i5.0 63.3-80.7 Sr-89 12.317.6 10.Di5.0 1.3-18.7 Sr-90 14.712.4 15.0il.5 12.4-17.6 Co-60 14.712.4 15.015.0 6.3-23.7 Cs-134 12.Di2.0 15.015.0 6.3-23.7 Cs-137 14.012.0 12.015.0 3.3-20.7 12

l 6

Table A-1.

(continued)

Concentration in pCi/lb Lab Sample Date TIML Result EPA Resultd Code Type Collected Analysis 12ac 15, N=1 Control Limits STW-413 Water May 1985 Sr-89 36.0t12.4 39.015.0 30.3-47.7 Sr-90 14.314.2 15.0*1.5 12.4-17.6 STW-414 Water May 1985 Gr. alpha 8.3f4.1 12.015.0 3.3-20.7 Gr. beta 8.711.2 11.015.0 2.3-19.7 STW-416 Water June 1985 Cr-51 44.716.0 44.0t5.0 45.3-52.7 Co-60 14.311.2 14.015.0 5.3-22.7 Zn-65 50.317.0 47.015.0 38.3-55.7 Ru-106 55.315.8 62.015.0 53.3-70.7 Cs-134 32.7tl.2 35.015.0 26.3-43.7 Cs-137 22.712.4 20.015.0 11.3-28.7 STW-418 Water June 1985 H-3 24461132 24161351 1807-3025 STM-421 Milk June 1985 Sr-89 10.314.6 11.015.0 2.3-19.7 Sr-90 9.012.0 11.011.5 8.4-13.6 I-131 11.7tl.2 11.Di6.0 0.6-21.4 Cs-137 12.711.2 11.0*5.0 2.3-19.7 K

1512162 15251132 1393-1657 STW-423 Water July 1985 Gr. alpha 5.010.0 11.0*5.0 2.3-19.7 Gr. beta 5.0i2.0 8.015.0 0.0-16.7 STW-425 Water August 1985 I-131 25.713.0 33.016.0 22.6-43.4 STW-426 Water August 1985 H-3 4363f83 4480i447 3704-5256 STAF-427 Air August 1985 Gr. alpha 11.310.6 13.015.0 4.3-21.7 Filter Gr. beta 46.011.0 44.0*5.0 35.3-52.7 Sr-90 17.710.6 18.011.5 15.4-20.6 Cs-137 10.310.6 8.0*5.0 0.0-16.7 STW-429 Water Sept 1985 Sr-89 15.7A0.6 20.015.0 11.3-28.7 Sr-90 7.010.0 7.011.5 4.4-9.6 STW-430 Water Sept 1985 Ra-226 8.210.3 8.911.3 6.6-11.1 Ra-228 4.110.3 4.610.7 3.4-5.8 STW-431 Water Sept 1985 Gr. alpha 4.7f0.6 8.015.0 0.0-16.7 Gr. beta 4.711.2 8.015.0 0.0-16.7 13

m._

O i

Table A-1.

(continued)

Concentration in pCi/lb Lab Sample Date TIML Result EPA Resultd Code Type Collected Analysis i20c 15, N=1 Control Limits STW-433 Water Oct 1985 Cr-51

<13 21.015.0 12.3-29.7 l

Co-60 19.310.6 20.015.0 11.3-28.7 Zn-65 19.710.6 19.0t 5. 0 10.3-27.7 Ru-106

<19 20.0i5.0 11.3-28.7 Cs-134 17.0tl.0 20.0i5.0 11.3-28.7 Cs-137 19.311.2 20.015.0 11.3-28.7 STW-435 Water Oct 1985 H-3 1957t50 1974t345 1376-2572 STW-436 Water Oct 1985 437 (Blind)

Sample A Gr. alpha 53.0il.0 52.0113 29.4-74.6 Ra-226 5.910.1 6.311.0 4.1-7.9 Ra-228 8.ci0.1 10.111.5 7.5-12.7 Uranium nae 8.0i10.4 0.0-18.4 Sample B Gr. beta 85.7f2.5 75.0i5.0 76.3-83.7 Sr-89 21.311.5 27.025.0 18.3-35.7 Sr-90 10.310.6 9.011.5 6.4-11.6 Co-60 18.311.2 18.015.0 9.3-26.7 Cs-134 16.311.2 18.0f5.0 9.3-26.7 Cs-137 19.0il.0 18.0i5.0 9.3-26.7 STM-439 Milk Oct 1985 Sr-89 50.310.6 48.0i5.0 39.3-56.7 Sr-90 23.310.6 26.011.5 23.4-28.6 I-131 45.713.2 42.016.0 31.6-52.4 Cs-137 60.710.6 56.0i5.0 47.3-64.7 K

1547t29 1540i77 1406-1674 STW-441 Water Nov 1985 Gr. alpha 5.310.6 10.015.0 1.3-18.7 I

Gr. beta 11.711.2 13.015.0 4.3-21.7 l

STW-443 Water Dec 1985 1-131 46.7t2.1 45.016.0 34.6-55.4 l

STW-444 Water Dec 1985 Ra-226 6.510.1 7.111.1 5.2-9.0 Ra-228 6.110.1 7.3 1.1 5.4-9.2 STW-445 Water Jan 1986 Sr-89 29.712.5 31.015.0 22.3-39.7 Sr-90 13.7i0.6 15.0il. 5 12.4-17.6 STW-446 Water Jan 1986 Gr. alpha 3.0i0.0 3.015.0 0.0-11.7 Gr. beta 5.310.6 7.015.0 0.0-15.7 14

4 Table A-1.

(continued)

Corcentration in pCi/lb Lab Sample Date TIML Result EPA Resultd Code Type Collected Analysis 120c 15, N=1 Control Limits STF 447 Food Jan 1986 Sr-89 24.322.5 25.0t5.0 16.3-33.7 Sr-90 17.3i0.6 10.011.5 7.4-12.6 I-131 22.7t2.3 20.Di6.0 9.6-30.4 Cs-137 16.3t0.6 15.0t5.0 6.3-23.7 K

927146 950t144 701-1199 STW-448 Water Feb 1986 Cr-51 45.0i3.6 38.015.0 29.3-46.7 Co-60 19.711.5 18.015.0 9.3-26.7 Zn-65 44.0t3.5 40.C?r,.0 31.3-48.7 Ru-106

<9.0 0.0i5.0 0.0-8.7 Cs-134 28.312.3 30.015.0 21.3-38.7 Cs-137 23.7i0.6 22.0i5.0 13.3-30.7 STW-449 Water Feb 1986 H-3 5176148 52271525 4317-6137 STW-450 Water Feb 1986 U total 8.Di0.0 9.0i6.0 0.0-19.4 STM-451 Milk Feb 1986 I-131 7.010.0 9.016.0 0.0-19.4 STW-452 Water March 1986 Ra-226 3.810.1 4.1i0.6 3.0-5.2 Ra-228 11.0f0.5 12.411.8 9.2-15.5 STW-453 Water March 1986 Gr. alpha 6.710.6 15.0t5.0 6.3-23.7 Gr. beta 7.3i0.6 8.015.0 0.0-16.7 STW-454 Water April 1986 I-131 7.0i0.0 9.0i6.0 0.0-19.4 STW-455 Water April 1986 456 (Blind)

Sample A Gr. alpha 15.011.0 17.0i5.0 8.3-25.7 Ra-226 3.110.1 2.910.4 2.1-3.7 Ra-228 1.5i0.2 2.0f0.3 1.5-2.5 Uranium 4.7i0.6 5.016.0 0.0-15.4 l

1 i

Sample B Gr. beta 28.711.2 35.015.0 26.3-43.7 Sr-89 5.710.6 7.015.0 0.0-15.7 Sr-90 7.Di0.0 7.Dil. 5 4.4-9.6 Co-60 10.7tl.5 10.015.0 1.3-18.7 i

Cs-134 4.0il.7 5.015.0 0.0-13.7 Cs-137 5.310.6 5.015.0 0.0-13.7 15

e Table A-1.

(continued)

Concentration in pCi/lb Lab Sample Date TIML Result EPA Resultd Code Type Collec ted Analysis t2ac is, N=1 Control Limits STAF-457 Air April 1986 Gr. alpha 13.710.6 15.015.0 6.3-23.7 Filter Gr. beta 46.310.6 47.0t5.0 38.3-55.7 l

Sr-90 14.710.6 18.011.5 15.4-20.6 Cs-137 10.710.6 10.015.0 1.3-18.7 STU-458 Urine April 1986 Tritium 4313170 4423i189 4096-4750 STW-459 Water May 1986 Sr-89 4.310.6 5.015.0 0.0-13.7 Sr-90 5.010.0 5.0il.5 2.4-7.6 STW-460 Water May 1986 Gr. alpha 5.310.6 8.0i5.0 0.0-16.7 Gr. beta 11.3fl.2 15.015.0 6.3-23.7 STW-461 Water June 1986 Cr-51

<9.0 0.015.0 0.0-8.7 Co-60 66.011.0 66.015.0 57.3-74.7 Zn-65 87.311.5 86.015.0 77.3-94.7 Ru-106 39.7i2.5 50.015.0 41.3-58.7 Cs-134 49.3f2.5 49.015.0 40.3-57.7 Cs-137 10.311.5 10.015.0 1.3-18.7 STW-462 Water June 1986 Tritium 3427125 3125i361 2499-3751 STM-464 Milk June 1986 Sr-89

<1.0 0.0i5.0 0.0-8.7 Sr-90 15.3i0.6 16.011.5 13.4-18.6 I-131 48.312.3 41.016.0 30.6-51.4 Cs-137 43.7tl.5 31.0i5.0 22.3-39.7 K

1567t114 1600180 1461-1739 STW-465 Water July 1986 Gr. alpha 4.710.6 C.015.0 0.0-14.7 Gr. beta 18.711.2 18.0i5.0 9.3-26.7 STW-467 Water August 1986 I-131 30.3f0.6 45.016.0 34.4-55.4 STW-468 Water August 1986 Pu-239 11.310.6 10.111.0 8.3-11,9 STW-469 Water August 1986 Uranium 4.010.0 4.0i6.0 0.0-14.4 STAF-470 Air Sept 1986 Gr. alpha 19.311.5 22.015.0 13.3-30.7 471 Filter Gr. beta 64.0f2.6 66.015.0 57.3-74.7 472 Sr-90 22.0i1.0 22.015.0 19.4-24.6 Cs-137 25.711.5 22.0i5.0 13.3-30.7 STW-473 Water Sept 1986 Ra-226 6.010.1 6.110.9 4.5-7.7 Ra-228 8.711.1 9.111.4 6.7-11.5 16

4 Table A-1.

(continued).

Concentration in pCi/lb Lab Sample Date TIML Result EPA Resultd Code Type Collected Analysis 120c 15, N=1 Control Limits STW-474 Water Sept 1986 Gr. alpha 16.3t3.2 15.0t5.0 6.3-23.7 Gr. beta 9.0il.0 8.0i5.0 0.0-16.7 STW-475 Water Oct 1986 Cr-51 63.315.5 59.0i5.0 50.3-67.7 Co-60 31.0i2.0 31.0*5.0 22.3-39.7 Zn-65 87.315.9 85.0i5.0 76.3-93.7 Ru-106 74.7t7.4 74.0i5.0 65.3-82.7 Cs-134 25.7i0.6 28.0t5.0 19.3-36.7 Cs-137 46.311.5 44.0i5.0 35.3-52.7 STW-476 Water Oct 1986 H-3 5918160 59731597 4938-7008 SPW-477 Water Oct 1986 478 (Blind)

Sample A Gr. alpha 34.016.0 40.0*5.0 31.3-48.7 Ra-226 5.810.2 6.0i0.9 4.4-7.6 Ra-228 2.7tl.0 5.0f0.8 3.7-6.3 Uranium 11.010.0 10.016.0 0.0-20.4 Sample B Gr. beta 38.711.2 51.015.0 42.3-59.7 Sr-89 5.0*0.0 10.0i5.0 1.3-18.7 Sr-90 3.0f0.0 4.Dil.5 1.4-6.6 Co-60 24.7tl.2 24.015.0 15.3-32.7 Cs-134 11.0i2.0 12.015.0 3.3-20.7 Cs-137 9.311.2 8.Di5.0 0.0-16.7 STM-479 Milk Nov 1986 Sr-89 7.711.2 9.0i5.0 0.3-17.7 I

Sr-90 1.010.0 0.0*1.5 0.0-2.6 I-131 52.313.1 49.0*6.0 38.6-59.4 Cs-137 45.7f3.1 39.0i5.0 30.3-47.7 l

K 1489f104 1565t78 1430-1700 STU-480 Urine Nov 1986 H-3 5540f26 52571912 4345-6169 STW-481 Water Nov 1986 Gr. alpha 12.014.0 20.0*5.0 11.3-28.7 i

Gr. beta 20.013.5 20.Di5.0 11.3-28.7 l

STW-482 Water Dec 1986 Ra-226 6.710.2 6.811.0 5.0-8.6 Ra-228 5.210.2 11.111.7 8.2-14.0 STW-483 Water Jan 1987 Sr-89 19.715.0 25.015.0 16.3-33.7 Sr-90 21.0*2.0 25.011.5 22.4-27.6 17

Table A-1.

(continued).

Concentration in pCi/lb Lab Sample Date TIML Result EPA Resultd Code Type Collec ted Analysis

  • 2ac 15, N=1 Control Limits STW-484 Water Jan 1987 Pu-239 17.0i2.3 16,711.7 13.8-19.6 STF-486 Food Jan 1987 Sr-90 36.014.0 49.0i10.0 31.7-66.3 1-131 78.0t3.4 78.Di8.0 64. 1 -91. 9 Cs-137 89.7t3.0
84. Di5.0 75.3-92.7 K

942156 980149 895-1035 STF-487 Food Jan 1987 SR-90 2.010.0 (Blank) 1-131

<3 Cs-137

<2 K

9931102 STW-488 Water Feb 1987 Co-60 49.0i0.0 50.015.0 41.3-58.7 Zn-65 96.017.2 91.015.0 82.3-99.7 Ru-106 92.0t20.2 100.015.0 91.3-108.7 Cs-134 53.0i3.4 59.0f5.0 50.3-67.7 Cs-137 89.314.6 87.015.0 78.3-95.7 STW-489 Water Feb 1987 H-3 4130t140 42091420 3479-4939 STW-490 Water Feb 1987 Uranium 8.311.2 8.016.0 0.0-18.4 STM-491 Milk Feb 1987 I-131 10.0t0.0 9.0f0.9 7.4-10.6 STW-492 Water Mar 1987 Gr. alpha 3.7*1.2 3.015.0 0.0-11.7 Gr. beta 11.3*1.2 13.0i5.0 4.3-21.7 STW-493 Water Mar 1987 Ra-226 7.0t0.1 7.3*1.1 5.4-9.2 Ra-228 7.1*2.3 7.511.1 5.5-9.5 STW-494 Water Apr 1987 I-131 8.010.0 7.0f0.7 5.8-8.2 STAF-495 Air Apr 1987 Gr. alpha 15.010.0 14.0t5.0 5.3-22.7 Filter Gr. beta 41.0t2.0 43.015.0 34.3-51.7 Sr-90 16.311.2 17.011.5 14.4-19.6 i

Cs-137 7.0i0.0 8.015.0 0.0-16.7 l

STW-496 Water Apr 1987 497 (Blind)

Sample A Gr. alpha 30.7*1.2 30.018.0 16.1-43.9 Ra-226 3.910.2 3.910.6 2.9-4.9 Ra-228 4.9*0.9 4.0iO.6 3.0-5.0 Uranium 5.Di0.0 5.016.0 0.0-15.4 18

'O

' ' ~ -- - -----

~-'

Table A-1.

(continued)

Concentration in pCi/lb Lab Sample Date TIML Result EPA Resultd Code Type Collec ted Analysis 12oc Is, N=1 Control Limits STW-496 Water Apr 1987 497 (Blind)

Sample B Gr. Beta 69.319.4

66. 0i5.0 57.3-74.7 Sr-89 16.3t3.0 19.0i5.0 10.3-27.7 Sr-90
10. 0t0. 0 10.0il.5 7.4-12.6 Co-60 8.313.0 8.015.0 0.0-16.7 Cs-134 19.012.0 20.015.0 11.3-28.7 Cs-137 14.7tl.2 15.0i5.0 6.3-23.7 STU-498 Urine Apr 1987 H-3 6017f494 5620i795 4647-6593 STW-499 Water May 1987 Sr-89 38.0i6.0 41.015.0 32.3-49.7 Sr-90 21.0i2.0 20.0il.5 17.4-22.6 STW-500 Water May 1987 Gr. alpha 9.0i3.4 11.015.0 2.3-19.7 Gr. beta 10.3tl.2 7.015.0 0.0-15.7 STW-501 Water June 1987 Cr-51 40.018.0 41.015.0 32.3-49.7 Co-60 60.313.0
64. 0i5.0 55.3-72.7 Zn-65 11.315.0 10.0i5.0 1,3-18.7 Ru-106 78.316.4 75.015.0 66.3-83.7 i

Cs-134 36.7t3.0 40.015.0 31.3-48.7 Cs-137 80.314.2 80.015.0 71.3-88.7 STW-502 Water June 1987 H-3 2906186 2895t357 2277-3513 STW-503 Water June 1987 Ra-226 6.9i0.1 7.3tl.1 5.4-9.2 Ra-228 13.311.0 15.212.3 11.2-19.2 STM-504 Milk June 1987 Sr-89 57.014.3 69.0i5.0 60.3-77.7 Sr-90 32.0*1.0 35.Dil.5 32.4-37.6 i

I-131 64.012.0 59.0i6.0 48.6-69.4 Cs-137 77.710.6 74.015.0 65.3-82.7 K

1383t17 1525176 1393-1657 STW-505 Water July 1987 Gr. alpha 2.310.7 5.015.0 0.0-13.7 Gr. beta 4.011. 0 5.015.0 0.0-13.7 l

STF-506 Food July 1987 I-131 82.714.6 80.018.0 66.1-93.9 Cs-137 53.713.0 50.015.0 41.3-58.7 i

K 1548157 1680184 1534-1826 i

STW-507 Water Aug 1987 I-131 45.714.2 48.016.0 37.6-58.4 1

l STW-508 Water Aug 1987 Pe

9

5. 81 0. 2 5.310.5 4.4-6.2 i

19

O' 4

Table A-1.

(continued)

Concentration in pCi/lb Lab Sample Date TIML Result EPA Resultd Code Type Collected Analysis

  • 2 c Is, N=1 Control Limits

.STW-509 Water Aug 1987 Uranium 13.310.3 13.016.0 2.6-23.4 STAF-510 Air Aug 1987 Gr. alpha 9.7i0.4 10.0t5.0 1.3-18.7 Filter Gr. beta 28.310.6 30.0*5.0 21.3-38.7 Sr-90 10.0*0.9 10.0tl.5 7.4-12.6 Cs-137 10.0tl.0 10.0i5.0 1.3-18.7 STW-511 Water Sept 1987 Ra-226 9.910.1 9.711.5 7.2-12.2 Ra-228 8.lil.4 6.311.0 4.6-8.0 STW-512 Water Sept 1987 Gr. alpha 2.0t0.6 4.0i5.0 0.0-12.7 Gr. beta 11.3*1.3 12.0*5.0 3.3-20.7 STW-513 Water Oct 1987 H-3 4473i100 44921449 3714-5270 STW-514 Water A Oct 1987 Gr. alpha 29.312.6 28.017.0 15.9-40.1 Ra-226 4.910.1 4.810.7 3.6-6.1 Ra-228 4.2il.0 3.610.5 2.7-4.5 Uranium 3.010.1 3.0i6.0 0.0-13.4 STW-515. Water 8 Oct 1987 Gr. beta 72.312.7 72.015.0 63.3-80.7 Sr-89 14.3tl.3 16.0t5.0 7.3-24.7 Sr-90 9.710.4 10.Dil.5 7.4-12.6 Co-60 16.7f3.0 16.015.0 7.3-24.7 Cs-134 16.7t2.3 16.015.0 7.3-24.7 Cs-137 24.313.3 24.0t5.0 15.3-32.7 STW-516 Water Oct 1987 Cr-51 80.3*17.5 70.015.0 61.3-78.7 Co-60 16.0f2.3 15.0i5.0 6.3-23.7 Zn-65 46.3i5.6 46.015.0 37.3-54.7 Ru-106 57.3i15.4 61.0i5.0 52.3-69.7 Cs-134 23.7t2.5 25.0t5.0 16.3-33.7 Cs-137 51.7*3.2 51.0i5.0 42.3-59.7 STU-517 Urine Nov 1987 H-3 72671100 74321743 6145-8719 STW-519 Water Dec 1987 I-131 26.013.0 26.0*6.0 15.6-36.4 1

a Results obtained by Teledyne Isotopes Midwest Laboratory as a participant in the i

environmental sample crosscheck program operated by the Intercomparison snd Cali-bration Section, Quality Assurance Branch, Environmental Monitoring and Support Laboratory, U. S. Environmental Protection Agency (EPA), Las Vegas, Nevada, b All results are in the pCi/1, except for elemental potassium (K) data in milk, which are in mg/1; air filter samples, which are in pCi/ filter; and food, which is in mg/kg.

c Unless otherwise indicated, the TIML results are given as the mean 12 standard deviations for three determinations.

d USEPA results are presented as the known values and expected laboratory precision (15,1 determination) and control limits as defined by EPA.

e NA = Not analyzed.

20

d Table A-2.

Crosscheck program results, thermoluminescent dosimeters (TLDs).

mR d

Teledyne Average 12 e Lab TLD Result Known (all Code Type Measurement 12aa Valuec participants) 2nd International Intercomparisonb CaF :Mn Field 17.011.9 17.1 16.417.7 115-2 2

Bulb Lab 20.814.1 21.3 18.8t7.6 3rd International Intercomparisone CaF :Mn Field 30.713.2 34.914.8 31.513.0 115-3 2

Bulb Lab 89.616.4 91.7114.6 86.2124.0 4th International Intercomparisonf CaF :Mn Field 14.111.1 14.111.4 16.019.0 115-4 2

ScTb Lab (Low) 9.311.3 12.212.4 12.027.6 Lab (High) 40.411.4 45.819.2 43.9113.2 Sth International Intercomparison9 CaF :Mn Field 31.411.8 30.016.0 30.2114.6 115-5A 2

Bulb Lab at 77.415.8 75.217.6 75.8140.4 beginning Lab at 96.615.8 88.418.8 90.7131.2 end

Table A-2.

(Continued) mR d

Teledyne Average 120 Lab TLD Result Known (all Code Type Measurement 12aa valueC participants) 115-5B LiF-100 Field 30.314.8 30.016.0 30.2114.6 Chips Lab at 81.117.4 75.217.6 75.8140.4 beginning Lab at 85.4111.7 88.418.8 90.7131.2 the end 1

h 7th International Intercomparison 115-7A LiF-100 Field 75.412.6 75.816.0 75.1129.8 Chips Lab (Co-60) 80.013.5 79.914.0 77.9t27.6 Lab (Cs-137) 66.612.5 75.013.8 73.0t22.2 CaF :Mn Field 71.512.6 75.816.0 75.1129.8 115-78 2

Bulbs Lab (Co-60) 84.816.4 79.914.0 77.9127.6 Lab (Cs-137) 78.811.6 75.013.8 73.0122.2 CaSO :Dy Field 76.812.7 75.816.0 75.1129.8 115-7C 4

Cards Lab (Co-60) 82.513.7 79.914.0 77.9127.6 s

Lab (Cs-137 79.013.2 75.013.8 73.0122.2 4

Table A-2.

(Continued) mR d

Teledyne Average 120 Lab TLD Result Known (all Code Type Measurement 12aa Valuec participants) i 8th International Intercomparison ll5-8A LiF-100 Field Site 1 29.511.4 29.711.5 28.9112.4 Chips Field Site 2 11.310.8 10.410.5 10.119.06 Lab (Cs-137) 13.710.9 17.210.9 16.216.8 CaF :Mn Field Site 1 32.311.2 29.711.5 28.9112.4 115-88 2

Bulbs Field Site 2 9.011.0 10.410.5 10.119.0 Lab (Cs-137) 15.810.9 17.210.9 16.216.8 Il5-8C CaSO :Dy Field Site 1 32.310.7 29.711.5 28.9112.4 4

Cards 0

Field Site 2 10.610.6 10.410.5 10.119.0 Lab (Cs-137 18.110.8 17.210.9 16.216.8 Lab result given is the mean 12 standard deviations of three determinations.

8 b Second International Intercomparison of Environmental Dosimeters conducted in April of 1976 by the Health and Safety Laboratory (GASL), New York, New York, and the School of Public Health of the University of Texas, Houston, Texas.

c Value determined by sponsor of the intercomparison using continuously operated pressurized ion chamber.

d Mean 12 standard deviations of results obtained by all laboratories participating in the program.

e Third International Intercomparison of Environmental Dosimeters conducted in sunener of 1977 by Oak Ridge National Laboratory and the School of Public Health of the University of Texas, Houston, Texas.

f Fourth International Intercomparison of Environmental Dosimeters conducted in sonener of 1979 by the School of Public Health of the University of Texas, Houston, Texas.

9 Fif th International Intercomparison of Environmental Dosimeter conducted in fall of 1980 at Idaho Falls, Idaho and sponsored by the School of Public Health of the University of Texas, Houston, Texas and Environmental Measurements Laboratory, New York, New York, U.S. Department of Energy.

h Seventh International Intercomparison of Environmental Dosimeters conducted in the spring and sunener of 1984 at Las Vegas, Nevada, and sponsored by the U.S. Department of Energy, the U.S. Nuclear Regulatory Commission, and the U.S. Environmental Protection Agency.

g Eighth International Intercomparison of Environmental Dosimeters conducted in the fall and winter of 1985-1986 at New York, New York, and sponsored by the U.S. Department of Energy.

4 Table A-3.

In-house spiked samples.

Concentration in pCi/1 Lab Sample Date TIML Result Known Expec ted Code Type Collec ted Analysis n=3 Activity Precision 1s, n=3a QC-MI-6 Milk Feb. 1986 Sr-89 6.0tl.9 6.4t3.0 8.7 Sr-90 14.2tl.7 12.9*2.0 5.2 1-131 34.2*3.8 35.2*3.5 10.4 Cs-134 32.0*1.8 27.3t5.0 8.7 Cs-137 35.8t2.1 35.0i5.0 8.7 QC W-14 Water Mar. 1986 Sr-89 1.610.4 1.6tl.0 7.1 Sr-90 2.410.2 2.412.0 4.2 QC-W-15 Water Apr. 1986 I-131 44.9*2.4 41.St7.0 10.6 Co-60 10.6*1.7 12.1*S.0 7.lb Cs-134 30.2*2.4 25.8i8.0 7.lb Cs-137 21.9*1.9 19.915.0 7.lb QC-MI-7 Milk Apr. 1986 1-131 39.7t3.3 41.Si7.0 10.4 Cs-134 28.7*2.8 25.8t8.0 8.7 Cs-137 21.2t2.8 19.915.0 8.7 SPW-1 Water May 1986 Gross alpha 15.8*1.8 18.015.0 Sc QC-W-16 Water June 1986 Gross alpha 16.2i0.7 16.912.5 8.7 Gross beta 38.4i3.5 30.2*5. 0 8.7 QC-MI-9 Milk June 1986 Sr-89

<1.0 0.0 7.lb Sr-90 12.611.8 13.3*3.0 4.2b I-131 38.9i7.0

34. 8*7.0 10.4 Cs-134 33.0*3.4 36.lt5.0 8.7 Cs-137 38.Si2.8 39.0i5.0 8.7 SPW-2 Water June 1986 Gross alpha 16,811.8 18.0i5.0 Sc SPW-3 Water June 1986 Gross alpha 17.710.8 18.Di5.0 SC QC-W-18 Water Sep. 1986 Cs-134 34.7i5.6 31.315.0 8.7 Cs-137 51.1*7.0 43.3t8.0 8.7 QC-W-19 Water Sep. 1986 Sr-89 13.614.1 15.6t3.5 7.lb Sr-90 6.4tl.6 6.2t2.0 4.2b f

24

Table A-3.

In-house spiked samples (continued)

Concentration in pCi/l Lab Sample Date TIML Result Known Expec ted Code Type Collec ted Analysis n=3 Ac tivity Precision 15, n=38 QC-W-21 Water Oc t.1986 Co-60 19.2t2.2 18.St3.0 8.7 Cs-134 31.715.2 25.618.0 8.7 Cs-137 23.8tl.0 21.6i5.0 8.7 QC-MI-11 Milk 0:t 1986 Sr-89 12.311.8 14.313.0 8.7 QC-W-20 Water Nov.1986 H-3 38551180 3960t350 520b QC-W-22 Water Dec. 1986 Gross alpha 9.811.4 11.214.0 8.7 Gross beta 21.712.0 23.815.0 8.7 QC-W-23 Water Jan. 1987 I-131 29.812.5

27. 9t3.0 10.4 QC-MI-12 Milk Jan. 1987 I-131 36.511.3 32.615.0 10.4 Cs-137 32.614.2 27.4*8.0 8.7 SPM-13 Milk Jan 1987 Sr-89 10.4i2.1 12.214.0 8.7 Sr-90 14.6*1.6 12.6*3.0 5.2 I-131 49.Sil.2 54.918.0 10.4 Cs-134

<1.6 0.0 8.7 Cs-137 33.310.6 27.418.0 8.7 SPW-24 Water Mar 1987 Sr-89 24.7*3.6 25.9*5.0 8.7 Sr-90 23.9i3.8 22.818.0 5.2 SPW-25 Water Apr 1987 I-131 28.0il.9 29.315.0 10.6 1

SPM-14 Milk Apr 1987 I-131 25.012.2 23.9t5.0 10.4 Cs-134

<2.1 0.0 8.7 Cs-137 34.212.0 27.2*7.0 8.7 l

l SPW-26 Water Jun 1987 H-3 3422i100 3362t300 520 Co-60 24.811.4 26.517.0 8.7 Cs-134

<2.0 0.0 8.7 Cs-137 21.210.5 21.617.0 8.7 l

SPW-27 Water Jun 1987 Gr. alpha 8.Sil.9 10.114.0 8.7 Gr. beta 22.611.9 21.2i5.0 8.7 SPW-28 Water Jun 1987 Gr. alpha 8.711.3 10.114.0 8.7 l

Gr. beta 12.215.2 9.413.0 8.7 25 I

O Table A-3.

In-house spiked samples (continued)

Concentration in pC1/1 Lab Sample Date TIML Result Known Ex pec ted Code Type Collec ted Analysis n=3 Ac tiv ity Precision 1s, n=3a SPW-29 Water Jun 1987 Gr. alpha 16.411.3 18.9*5.0 8.7 Gr. beta 15.9t4.0 11.814.0 8.7 SPM-15 Milk Jul 1987 Sr-89 19.411.6 18.813.5 5.2 1-131 43.5i0.7 45.317.0 10.4 Cs-134

17. 9t 2. 2 16.0*5.3 8.7 Cs-137 25.411.8 22.715.0 8.7 SPW-30 Water Sep 1987 Sr-89 17.Si3.0 14.315.0 8.7 Sr-90 18.4f2.2 17.512.2 5.2 SPW-31 Water Oct 1987 H-3 2053193 2059i306 520 a

6 n=3 unless noted otherwise.

n=

2.

c n=1.

l l

26

O Table A-4.

In-house "blank" samples.

Concentration in pCi/1 Acceptance Lab Sample Date Results Criteria Code Type Collec ted Analysis (4.66a)

(4.66o)

BL-1 D.I. Water Nov.1985 Gross alpha

<0.1

<1 Gross beta

<0.4

<4 BL-2 0.1. Water Nov. 1985 Cs-137 (gama)

<1.9

<10 BL-3 0.1 Water Nov. 1985 Sr-89

<0.5

<5 Sr-90

<0.6

<1 BL-5 D.I. Water Nov. 1985 Ra-226

<0.4

<1 Ra-228

<0.4

<1 SPW-2265 D.I. Water Apr. 1985 Gross alpha

<0.6

<1 Gross beta

<2.2

<4 Sr-89

<0.2

<5 Sr-90

<0.4

<1 1-131

<0.2

<1 Cs-137 (gama)

<7.4

<10 BL-6 0.1. Water Apr. 1986 Gross alpha

<0.4

<1 BL-7 0.1. Water Apr. 1986 Gross alpha

<0.4

<1 BL-8 D.I. Water June 1986 Gross alpha

<0.4

<1 BL-9 0.1. Water June 1986 Gross alpha

<0.3

<1 SPW-3185 D.I. Water Jan 1987 Ra-226

<0.1

<1 Ra-228

<0.9

<1 SPS-3292 Milk Jan 1987 1-131

<0.1

<1 Cs-134

<6.2

<10 Cs-137

<6.4

<10 SPW-3554 D.I. Water Feb 1987 H-3

<180

<300 Gross beta

<2.6

<4 SPS-3555 Milk Feb 1987 Sr-89

<0.6

<5 Sr-90 1.910.4a

<1 SPS-3731 Milk Mar 1987 Cs-134

<2.2

<10 Cs-137

<2.5

<10 a tow level (1 4 pCi/1) of Sr-90 concentration in milk is not unusual.

27

w l

i Table A-4.

In-house "blank" samples (continued),

i Concentration in pCi/1 Acceptance Lab Sample Date Results Criteria Code Type Collec ted Analysis (4.66, )

(4.66o )

)

SPS-3732 0.1. Water Mar 1987 Sr-89

<0.9

<5 l

Sr-90

<0.8

<1 1

1-131

<0.3

<1 Co-60

<2.3

<10 Cs-134 (Gamma)

<2.2

<10 Cs-137 (Gamma)

<2.4

<10 Ra-226

<0.1

<1 Ra-228

<1.0

<1 Np-237

<0.04

<1 Th-230

<0.05

<0.1 Th-232

<0.02

<0.1 U-234

<0.05

<0.1 U-235

<0.03

<0.1 U-238

<0.03

<0.1 SPS-4023 Milk May 1987 I-131

<0.1

<1 SPS-4203 0.I. Water May 1987 Gross alpha

<0.7

<1 Gross beta

<1.7 (4

SPS-4204 Milk May 1987 Sr-89

<0.5

<5 Sr-90 2.4i0.6a

<1 SPS-4390 Milk Jun 1987 Cs-134 (4.7

<10 Cs-137

<5.2

<10 SPS-4391 0.I. Water Jun 1987 Sr-89

<0.4

<5 Sr-90

<0.4

<1 1-121

<0.1

<1 Co-60

<3.8

<10 Cs-137

<5.7

<10 Ra-226

<0.1

<1 l

Ra-228

<0.9

<1 SPW-4627 0 I. Water Aug 1987 Gross alpha

<0.6

<1 Gross beta

<1.4

<4 Tritium

<150 SPS-4628 Milk Aug 1987 Sr-89

<0.6

<5 Sr-90 2.410.6

<1 SPS-4847 Milk Sep 1987 Cs 134

<4.4

<10 Cs-137

<5.3

<10 4 Low level (1 - 4 pCi/1) of Sr-90 concentration in milk is not unusual.

28

Table A-4.

In-house "blank' samples (continued).

Concentration in pCi/l Acceptance Lab Sample Date Results Criteria Code Type Collitc ted Analysis (4.66o)

(4.66o)

SPS-4848 0.1. Water Sep 1987 1-131

<0 2

<1 SPW-4849 0.I. Water Sep 1987 Co-60

<4.1

<10 Cs-134

<4.8

<10 Cs-137

<4.0

<10 Sr-89

<0.7

<5 Sr-90

<0.7

<1 SPW-4850 D.I. Water Sep 1987 Th-228

<0.04

<1 Th-232

<0.8

<1 V-234

<0.03

<1 U-235

<0.03

<1 V-238

<0.02

<1 Am-241 (0.06

<1 Cm-242

<0.04

<1 Ra-226

<0.1

<1 Ra-228

<1.0

<2 SPW-4859 D.I. Water Oct 1987 Fe-55

<0.5

<1 SPS-5348 Milk Dec 1987 Cs-134

<2.3

<10 Cs-137

<2.5

<10 SPW-5384 Water Dec 1987 Co-60

<2.8

<10 Cs-134

<2.6

<10 Cs-137

<2.8

<10 1-131

<0.2

<1 Ra-226

<0.1

<1 Ra-228

<1.2

<2 Sr-89

<0.5

<1 Sr-90

<0.4

<1 SPW-5385 Water Nov 1987 Gr. alpha

<0.4

<1 Gr. beta

<2.2

<4 Fe-55

<0.3

<1 SPS-5386 Milk Jan 1988 I-131

<0.1

<1 SPW-5448 "Dead" Water Jan 1988 H-3

<177

<300 i

29

TIML 6LINU-01 Revision 0, 12-29 86 ATTACHMENT B ACCEPTANCE CRITERIA FOR *$P!KE0" SAMPLES LABORATORY PRECISION:

ONE STANDARD DEVIATION VALUES FOR VARIOUS ANALYSES 4 One Standard Deviation Analysis Level for Single Determination Gama Emitters 5 to 100 pCi/ liter or kg 5 pCi/ liter

>100 pCi/ liter or kg 5% of known value Strontium-89b 5 to 50 pCi/ liter or kg 5 pCi/ liter

>50 pCi/ liter or kg 10% of known value Strontium-90b 2 to 30 pCi/ liter or kg 3.0 pCi/ liter

>30 pCi/ liter of kg 10% of known value Potassium

>0.1 g/ liter or kg 5% of known value Gross Alpha

<20 pCi/ liter 5 pCi/ liter

>20 pCi/ liter 25% of known value Gross Beta

<100 pCi/ liter 5 pCi/ liter

>100 pCi/ liter 5% of known value Tritium (4,000 pCi/ liter is = (pCi/ liter) =

169.85 x (known).0933

>4,000 pCi/ liter 10% of known value Radium-226,

<0.1 pCi/ liter 15% of known value Radium-228 Plutonium 0.1 pCi/ liter, gram, 10% of known value or sample Iodine-131, b

<55 pCi/ liter 6 pCi/ liter Iodine-129

>55 pCi/ liter 10% of known value Uranium-238,

<35 pCi/ liter 6 pCi/ liter Nickel-630,

>35 pCi/ liter Technetium-99b 15% of known value Iron-55b 50 to 100 pCi/ liter 10 pCi/ liter 10% of known value

  • From EPA publication, "Environmental Radioactivity Laboratory Intercompari-son Studies Program. Fiscal Year 1981-1982. EPA-600/4-81-004.

D TIML limit, i

30 l

a APPENDIX 1 DATA TABLES AND FIGURES t

l f

l 1

l l

1 i

31

TABLE 1.1-1 EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT Jan.-June 1987 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES Quarter Quarter Est. Total l

Unit FIRST SECOND

Error, A.

FISSION & ACTIVATION GASES

}.

Total Release Cl 1.76E+02 1.15 E +0 2 NA I

2.

Average release rate for period pCl/sec

2. 2 6E +01
1. 46E +01 i 3.

Percent of Tee.n Spec limit

  • 0.11 0.04 /

I Chimney & stack 0.07

/ 0.015 8.

IOOINE I

I 1

Total Iodine-131 Cl 3.37E-03 5.14E-03 hA I 2.

Average release rite for period pC1/sec 4.33E-04 6.54E-04 C.

PARTICULATES

1.

Particulates with half-lives

> 8 days Cl 7.69E-03 5.00E-02 NA I 2.

Average release rate for oarlod pC1/sec 9.89E-04 6.36E-03 3

Gross aloha ridloacti. */

Cl 1.08E-06 2.08E-07f D.

TRITIUM i 1.

Total Release C1 3.60E+01 2.63E+01 NA I 2.

Average release rate for meriod pCl/sec 4.63E 00 3.35E 00 E.

Iodine 131 & 133, Tritium and Particulates Percent of Ter.h spec Limit Chimnev & Stack 0.60 1.02

  • NOBLE GAS GAMMA / NOBLE GAS BETA
    • PROJECTED VALUE BASED ON PREVIOUS 6 MONTHS DATA 32 l

______________y

TABLE 1.1-1 (continued)

EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT July =Dec 1987 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES Quarter Quarter Est. To al Unit 3rd 4th Error. ".

A.

FISSION & ACTIVATION GASES 1.

Total Release Ci 7.00E01 1.16E01 2.

Average release rate for period' pCl/sec 8.81E00 1.46E00 3.

Percent of Tecn Spec limit

  • 0.02 8.18E-03 Chimney L stack 0.002 3.73E-03

.B.

100!NE I.

Total Iodine-131 C1 3.61E-03 2.38E-03

[

2.

Average release rate for oeriod pC1/sec 4.54E-04 2.99E-04 C.

PARTICULATES 1.

Particulates with half-lives

> 8 days Cl 1.53E-02 6.46E-03 2.

Average release rate for ceriod pCl/sec 1.92E-03 8.13E-04

3.. Gross alpha radioactivit/

C1 1.75E-05 3.84E-06 0.

TRITIUM l

}

1.

Total Release Cl 1.98E01 1.18E01 1 2.

Average release rate for period pCl/sec 2.49E00 1.48E00 E.

Iodine 151 & 133, Tritium and Particulates l

Percent of Tech spec Limit i

Chimney & stack 6.20E-01 6.40E-01

' NOBLE GAS GAMMA / NOBLE GAS BETA

    • PROJECTED VALUE BASED ON PREVIOUS 6 MONTHS AVAILABLE DATA.

33

0

- - - ~ - ~

9 TABLE 1.1-1 (continued)

MAIN CHIMNEY GASEOUS EFFLUENTS Ccntinuous Mode Batch Mode Quarter Quarter Quarter Quar:ce Nuclidas Released Unit FIRST SECOND i

1.

Fission gases I<r-85 Cl

<ttD

<ttD l

L

<r-85m Cl 2.25E+01 2.22E*01

'<r-87 Cl 1.s4E-01 1.79E 00 i

<r-88 Cl 1.65E+01 6.92E+00 I

C1 2.20E+01 2.78E+01

,(e 133 Xe-135 Cl 9.46E+01

1. 87 r.+01 te 135m Cl 1.08E 00 2.96t+01 (e-138 Cl 3.92E 00 6.35E 00 i

Cl Cl Cl l

Unidentified Cl

<tLD

<LLD

!.61E+02 1.13r+02 Total for Period Cl 1

l 2.

Iodines 1

i 1-131 C1 2.87E-03

,4.34E-03 1-133 Cl 1.550-02 2.63E-02 1-135 C1 2.58E-02 4.59E-02

'otal for Period Cl 4.42E-02 7.65E-02 l

l l

34 l

l r

TABLE 1.1-1 (continued)

MAIN CHIMNEY GASEOUS EFFLUENTS Continuous Mode Batch Mcce Quarter Quarter Quarter Quar:er :

Nuclides Released Unit 3rd 4th 1

1.

Fission gases l

' Kr-85 Cl

< LLD

< LLD

! Kr-85m C1 1.55E01 3.93E00 Kr-87 Cl 6.04E-01 1.19E00 Kr-88 Cl 9.17E-01 1.54E00 (e 133 Cl 1.21E01 4.54E-01 l

/e-135 C1 2.99E01 3.75E00 Xe-135m C1 4.80E00

<LLD Xe-138 Cl 6.15E00

<LLO Cl I

Cl Cl Unidentified Cl

<LLD

<LLO Total for Period Cl 7.00E01 1.09E01 2.

Icoines 1-131 C1 3.30E-03 2.21E-03

1-133 Cl 8.45E-03 1.29E-02

!I-135 C1 3.03E-02 2.04E-02 1

Total fo' Period C1 4.21E-02 3.55E-02 35

TABLE 1.1-1 (continued)

MAIN CHIMNEY GASE004 EFFLUENTS Continuous Mode Satch Mode Quarter Quarter Quarter Quarter !

Nuclides Released Unit FIRST SECOND 3.

Particulates i

Sr' 89*

Cl 2.18E-04 3.33E-04 i S r-90

  • Ci 5.16E-06 1.62E-05 Cs 134 Ci

<LLD

<tLD Cs-137 Cl 6.12E-04 9.97E-05 Sa~140 Cl 8.83E-04 1.15E-03 l

La-140 Cl

<tLD

<LLD I

Cr-51 Cl

<LLD

<LLD l

Mn-54 Cl

<LLD

<LLD

.Co 58 C1

<tLD

<LLD i

Co-60 Cl 6.29E-04 3.99E-04

I-131 Ci 4.10E-05 1.37E-04

!Aq110m Cl

<LLD 2.82E-04 I-133 Cl 1.09E-03 1.83E-03 I-135 Cl

<LLD 7.21E-03

'Fe-59 C'

<LLD 9.96E-06 1

Cl UNIDENTIFIED Cl

<lLD

<LLD i

TOTAL Cl 3.48E-03 1.15E-02 l

  • Based on previous six months data.

l 36 i

TABLE 1.1-1 (continued)

MAIN CHIMNEY GASECUS EFFLUENTS Continuous Mode Satch %de Quarter Quarter Quarter Quarter j

' Nuclides Released Unit 3rd 4th 3.

Particulates I

l Sr-89 C1 4.31E-04 4.00E-04 1

i Sr-90 C1 1.86E-05 5.33E-06 Cs-134 C1

< LLD

< LLD Cs-137 C1 4.94E-04 3.20E-04 Ba-140 C1 4.64E-04 5.58E-05 l

La-140 Cl

< LLD

< LLD i

'Cr-51 Cf

< LLD

< LLD Mn Cl

< LLD

< LLD i

.'Co-58 C1

< LLD

< LLD i

Co-60 C1 3 98E-04 6.28E-04 I-131 C1 4.46E-05 1.00E-04 Aq-110m Cl

< LLD

< LLD l

I l-133 Cl 9.28E-04 1.05E-03 l

C1 C1 I

Ci i

j UNIDENTIFIED cg

< LLD

< LLD WMkMEM51RIEdX TOTAL C1 2.78E-03 2.56F-01___

    • PROJECTED VALUES BASED ON PREVIOUS 6 MONTHS AVAILABLE DATA 37

4 TABLE 1.1-1 (continued)

REACTOR VENTS CASECUS EFFLUENTS Continuous Mode Batch Mede Quartir Quarter Quarter Quarter 1 Nuclides Released Unit FIRST SECOND I

1.

Fission gases I

<r-85 C1

<LLD

<LLD

<r-85m C1

<tLD

<tLD j

<r-87 Ci

<LLD

<LLD

<r-88 C1

<LLD

<LLD

'(e l 33 Cl 1.41E 00 5.48E-01 te-135 C1 1.40E+01 1.45E+00 Xe-135m C1

<LLD

<LLD l

Xe-138 Cl

<LLD

<LLD l

C1 Cl Total for Period C1

1. 54E+ 01 2.00E 00 l

2.

Iodines l

I-131 C1 4.31E-04 4.40E-04 I-133 Gi 1.2SE-03 2.86E-03 I 135 Cl 5.36E-03 7.44E-03 i

Total for Period C1

7.04E-03 1.07E-02 38

o l

1 TABLE 1.1-1 (continued) l I

REACTOR VENTILATION STACK GASECtJS EFFLUENTS I

Continuous Mode Batch Mode i

Quarter Quarter Quarter Quarter l Nuclides Released Unit 3rd 4th

- 1.

Fission gases l

<r-85 Cl

<LLD

<LLD i

<r-85m C1 (LLD

<LLD l

<e-87 C1

<LLD

<iLD I

<r-88 C1

<LLD

<LLD Xe 133 C1

<LLD 7.40E-01 Xe-135 C1

<lLD

<LLD l

Xe-135m Cl

<LLD (LLD Xe-138_

C1

<LLD

<LLD Ci i

C1 I

j Total for Period C)

<LLD 7.40E-01 l

2.

Icdines t

I i

I-131 C1 2.54E-04 2 34E-05 I-133 C1 1.21E-03 1.79E-04

-I-135 Cl 7.92E-04 4.65E-03 l

Total for Period C) 2.26E-03 4.85E-03 l

I 39 J

=

TABLE 1.1-1(continued)

REACTOR VENTS GASEQUS EFFLUENTS Continuous Mode Batch Mode Quarter Quarter Quarter Quarter l Nuclides Released Unit FIRST SECOND i

3.

Particulates Sr-89

  • Cl 4.23E-05 4.69E-05 Sr-90
  • Cl 1.33E-06 9.92E-06 I

i Cs-134 CI

<LLD

<LLD Cs-137 Cl 3.02E-04 2.52E-04 33-140 Cl 1.08E-04 5.81E-04 La-140 Cl

<LLD

<LLD f

Cr-51 Cl 9.65E-04 2.50E-02 Mn-54 C1 2.33E-05 7.23E-04 Co-58 Cl 6.77E-05 7.21E-04 Co-60 C1 1.46E-03 4.60E-03 f-131 Cl 3.04E-05 2.23E-04 iAq-110m Cl 7.25E-05 2.76E-04 l

l I-133 Cl 1.02E-03 2.91E-03 i I-135 Cl 5.78E-05 1.35E-03 l

Mo-99 Cl 5.66E-05 1.49E-03 l

l Zn-65 Cl

<LLD 2.63E-04 UNIDENTIFIED C1

<LLD

<LLD l

fTOTAL C1 4.21E-03 3.85E-02

  • Based on previous six months data.

40

TABLE 1.1-1 (continued)

REACTOR VENTILATION STACK GASE0US EFFLUENTS Continuous Mode Batch Mode Quarter Quarter Quarter Quarter j Nuclides Released Unit 3rd 4th 3.

Particulates sr-ag C1 4.58E-05 5.95E-05 l

l Sr-90 Cl 1.26E-05 4.40E-06 Cs-134 C1

< LLD

< LLD Cs-137 C1 4.61E-04 6.96E-04 Sa-140 Cl 5.62E-05

< LLD La-140 Cl

< LLD

< LLD Cr-51 C1 4.29E-03 5 35E-05 Mn-54 C1 1.00E-04 1.58E-04 Co-58 Cl 7.66E-05 1.37E-05

+

Co-60 Cl 2.73E-03 2.84E-03 f

I-131 C1 1.51E-05 4.57E-05 Aq-110m Cl 4.22E-05 7.61E-06 1, 1-133 C1 4.78E-04

< LLD i

I i 1-135 Cl 1.26E-03

< LLD As-76 Cl 2.32E-04

< LLD Ru-103 Cl 3 79E-04

< LLD Zr95 Cl 1.55E-05 1 36E-05 Ho99 Ci 2 31E-03

< LLD Nb95 ci

<LLD 9.76E-06 j.

Unidentified C1

<LLD

< LLD TOTAL Cl 1.25E-02 3.90E-03

  • PROJECTED VALUES BASED ON PREVIOUS 6 MONTHS AVAILABLE DATA 41

y TABLE 1.2-1 LIQUIO EFFLUENTS - SUMMATICN OF ALL RELEASES Quarter Quarter Est. Total j i

Unit FIRST SECOND Error.

v.

I A.

FISSION & ACTIVATION PROOUCTS

  • 1.

Total release (not including tritium, qases. alpha)

Cl 5.02E-03 4.89E-03 NA 2.

Average diluted concentration during batch discharge $r aeriod C1/ml 1.64E-09 2.05E-09 1.6E-02 4.0E-02 3.

Dercent of aoplicable limit

  • 1.3E-02 2.0E-02 I.

Maximum diluted concentration 4

during batch discharges pC1/ml 3.47E-09 3.08E-09 s.

TRITIus 1.

Total release Cl 1.28E;00 5.54E-01 NA l

2.

Average diluted concentration during batch discharges pC1/mi 4.18E-07 2.32E-07 3.

Percent of aoplicable limit 1.39E-02 7.73E-02 i

C.

DISSOLVED AND ENTRAINED GASES l

3 1.

Total release C1 4.86E-05 <LLD NA

, 2.

Average diluted concentration during batch discharges pC1/ml 1.59E-Il

<LLD 3.

Percent of aoplicable limit 7.95E-06 D.

GROSS ALPHA RADICACTIVITY I

1.

Total Release Ci (LLD

<LLD **

NA 2.

Average concentration released during batch discharges C1/ml

<LLD

<LLD l E.

VOLUME OF HASTE RELEASED (prior i

to dilution Liters 5.52E,05 2.85E +05 NA F.

VOLUME OF DILUTION WATER USED DURING BATCH OISCHARGES Liters 3.06E+09 2.39E409 NA l G.

TOTAL VOLUME OF OILUTICN WATER CURING PERICO (CUARTER) l Liters 8.09E&l2 1.49E+13 NA i

'WHOLE B00Y/CRGAN 9/0295c

    • PROJECTED VALUE BASED ON LAST 6 MONTHS 42

TABLE 1.2-1 (continued)

LIQUID EFFLUENTS - SUMMATICN OF ALL RELEASES Quarter Quarter Est. Total i

i Unit 3rd 4th Error. %

A.

FISSION & ACTIVATION PRODUCTS 1

Total release (not including tritium, gases, alpha)

Ci 9.81E-03 5.13E-02 2

2.

Average diluted concentration -

during batch dischargest ceriod pC1/ml 2.46E-09 9.10E-09 0.03 0.09 3.

Percent of aoplicable limit 0.02 1 0.04 4

Maximum ciluted concentration

_ l durinq batch discharges pCi/ml 8.52E-09 8.00E-08 B.

TRITIUM 1.

Total release Cl 1.55E00 3.54E00 2.

Average diluted concentration during batch discharges pCl/ml 3.88E-07 6.28E-07

~

3.

Percent of applicable limit 1.29E-02 2. 09 E -02; C.

DISSOLVE 0 AND ENTRAINED GASES 1.

Total release Cl 8.17E-05 3.34E-04 2.

Average diluted concentration during batch discharges pCl/ml 2.05E-11 5.92E-11

! 3.

Percent of applicable limit 1.03E-05 2.96E-05 O.

GROSS ALPHA RADI0 ACTIVITY 1.

Total Release C1 4.01E-05 2.52E-05

~2.

Average concentration released during batch discharges pCi/ml 1.01E-11 4.47E-12 l E.

VOLUME OF WASTE RELEASE 0 (prior to dilution Liters 6.29E05 1.87E06 i

F.

VOLUME OF OILUTION WATER USE0 OURING BATCH OISCHARGES Liters 3.99E09 5.64E09 I G.

70TAL VOLUME OF DILUTION i

WATER DURING PERIOD (CUARTER)

Liters 4.20E11 2.14E11

'WHOLE B00YiCRGAN 43

b' TABLE-1.2-1 (continued)

LIQUID EFFLUENTS Continuous Mode Batch Mode Quarter Quarte r Quarter Quar:er

' Nuclides Released Unit FIRST SECOND i

Sr-89 Cl 3.91E-05 9.09E-06 1

'Sr-90 Cl 1.05E-05 1.40E-05 Cs 134 Cl

<tLD 6.22E-06 I

Cs-137 Cl 5.18E-04

.6.99E-04 l

i I 131 Cl

<LLD 1.342-05 Co-58 C1 3.22E-05 1.57E-04 l Co-60 C1 1.99E-03 1.83E-03 I

r -59 C1

<LLD

<LLD J

e i

Zn-55 Cl 2.92E-05 9.61E-05 i Mn-54 Cl 2.59E-0.

3.43E-04 l

l Cr-51 Cl 1.14E-04 4.43E-04_j Zr-95 Cl

<LLD

<tLD 3

l<LLD

__Nb-95 Cl

<tLD Mo-99 Cl

<LLD

<LLD A -ilCm Cl 7.52E-04 1.02E-04 Q

l l

Ba-104 Cl

<LLD

<tLD l

t Cs-136 Cl

<LLD

<tLD e

l La-140 C1

<LLD 8.58E-06 Fe-55 C1 1.28E-03 1.17E-03 l

Tc-99m C1

<LLD 7.23E-06 Total for Period (above)

Cl 5.02E-03 4.90E-03 Xe-133 Cl 3.40E-05

<LLD

! (e 135 Cl 1.46E-05

,JLD

(

44 1

TABLE 1.2-1 (continued)

LIQUID EFFLUENTS Continuous Mode Betch Mode Quarter Quarter Quarter Quarter

, Nuclides Released Unit 3rd 4th

' sr-89 Cl 9.45E-06 2.36E-05 lSr-90 Cl 1.46E-05 3.44E-05 Cs 134 Cl 1.44E-05

< LLD Cs-137 Cl

7. 2 4E-04 1.76E-03 i I-131 C1 1.15E-05

< LLD Co-58 Cl

2. 72 E -04 7.51E-04 !

Co-60 C1 2.86E-03 1.29E-02 I Fe-59 Cl

< LLO 1.40E-04 2n-65 C1 4.26E-05 6.88E-04 i Mn-54 Cl 6.54E-04 1.30E-03 Cr-51 C1 3.23E-03 2.36E-02 I

Zr-95 Ci

< LLD l

< LLD

'Nb-95 Cl

< LLO 7.30E-05 Na-24 Cl

< LLD 1.41E-04 i

. Aq-110m C1 2.78E-04 1.34E-03 sb-125 Ci

< LLD 5.92E-05 l

< LLD 8.73E-05

,Sb-124 Cl 6.21E-06 3 73E-06

' La-140 Ci 1.69E-03 8.27E-03 Fe-55 Cl

< LLO 8.03E-05 Ru-103 Ci 9.81E-03 5.13E-02 Total for Period (above)

C1 3.90E-05 2.17E-04 l Xe-133 C1 (e 135 lCl l 4.27E-05 f.16E-04 {

t 45

e c>

TABLE 2.0-1 SOLIO RAb!OACTIVE WASTE SudhARY LNIr; i,;

L,...._,,

a a l u,, N WUAD t i a.

JANUAisi 27 TRANSPOR; 5URIAL UAin COMPANY SITE VOLUME NILL 1CURIEC O

v2/G?

Ct1 Emd 193.00 2555i.w 0

6 : e 8 ;'

t, N BWS i73.00 i S 8 5 6. u t.,

v:,0/,'U-HACKE USE 262e50 1303.00 0;/iS/87 h A.:KE USE i342.60 37.00 0, 22, 1/

N 8WS 193.00 i2495.00 vi/22/87 riACKE USE 262.50 iiiO.00 J i i.::9/07 MCKE USE 2342.60 iij.00 6'-J9/8/

CN

. W S 193.00 15210.00 e*
  • * *.:, x x w. + + *. e.+

,e *,.+ a * * * * *, * *

  • o *
  • x * * * * *, o x n m, * *,, * * >. *. 4. 4...

horiTHLY TOTALS =

4982.20

-/i723.0 U.T.

E C 0 t_0 G Y LIL

=

3 A R ',".d _ '. S O U T H C A R O L I tl A i;. ; ;

a C s-

- C HE r: flUCLEAR CO.

SCIENilF!C ECOLOGY GROLP JEG

=

46

o O

e TABLE 2.0-1 (continued)

JOLID FM1,'I G A L F I V E WA5TE Jut 1HAR(

LNIT. i/J l

QUnu Ji-127 J T AT IOri

~

Ic.3 R U A R T 8

l TiMtJSPOR T BURIAL l

RATE COMPAN; SITE VOLUFE MILLiC:.

.c

'.> 2 :. ;>, :-3,

LN n u:,

193.00 15s:

+

OJ/0o/s?

HACnE USE 105.00 1364.00

-)2, 1,, f 4 JN BWS 193.00 13271.00 02/ ' W '

C ri UWS 193.06 1309V.00 02/ :'), 2 7 daCKE USE 803.60

/a.70 l

w * * ># +- A e.

  • F ; W 4, 4 N N X *
  • 4 h # 7 h e # ft M S: n W :t
  • 4 X M * * * *
  • W f( W n K *, e W 'entt*+4x++**fr:%nMn+*-+

ci0 tm 4 L Y ;0iAL0 1437.6v 41 :> 1

=

GE L.-.

CCOLCGY DCC a pan 4WELL SOUTH CAROLINA

.HEri NUCLEAR CC.

CN

=

22G

.l lisNT1r'[C ECOLOGY GROUP 2

1 l

l l

l l

I 47

O TABLE 2.0-1 (continued)

SOLID RAD 10ACi1VE WHS1E..,LdMARf a n a. T S :i IyU r~ n.

r r.;.~ ;-. b rt

.s

-Luss r.- - a i

g u

or e a.,>

r1 ARCH 07 T?: Ar SPORT DURIAL JAlE COMPANY J. I T E VOLUhE MILLICUS.ii.S Os/05/ 0 /

CN BWS i93.00 10599.00 03/Oc/87 ri ACK E USE 93Z. 20 636.00 03/:;/O' EACKE USE 308.70 1265.00 0.~ / ' 2/ 6 ?

CN BWS i93.00 10083.00 03/ta/37 HACKE

'iSE 536.00 1220.00 03/iv/87 RAY Ti C.:

SEG t290 10 53.50 03/26,d' CN BWS

  • 93.00 13357.00 t
  • M n
  • W & + t ? * # # h h n e M *
  • M M 's. M M W 4 f. i s S W M # h # y w h h M e t +. m
  • t n n A * *. a X X h n W W m p M n ( % W ;( y g at s

in ; z iL 7 TOTALS =

2 6 4 6.!3 0 372i

.00 l

J J r_

_.. S. ECOLCGY

=

dart?WELL SOUTH CAROLINA S.1C

=

CHEH NUCLEAR CO.

i

'N 1

SEG = JCIENT;FIC ECOLOGY GROUP i

1 1

48

C TABLE 2.0-1 (continued)

SOLID 6 ADIOAC FIVE WASTE Sur1 MARY UNITS 1/2 QURD CITIES ST A T10rJ AFRIL 87 TMrJS?2RT BURIAL

./ 6 T E COnPANY SITE V OLLr* E rtiLLiCUR1ES

.e/03/a-CN LUS 193.00 26301.00 04/09/0?

c, fuJ; 193.00 23353.c0 04/.:9/07 CN LWS i77.00 i7305.00 34/ 22/3',

Cr4 BWS 193.00 2667i.00 04/24/'

'n4L K E USE 591.40 752.70 04/30/57 Ca BWS 193.00 49258.00

      • .***#**s***s*n**n****n-*****H
                            • n****x******************

Mor1THL: TOTALS =

1540.40 i 4D o... /0 USE = U.S.

ECOLOGY DSC = UARNWELL SuJTH CAROLINA CN

= Cndri NUCLEAR CO.

SEG = SCIENTIFIC ECCLOG't GROUP 49

C 4

TABLE 2.0-1 (continued)

SOLID RADI0 ACTIVE. Wr-iSTE JUhriARY UNITS 1/2 QUAD CITIES STATION ri A f 37 FR A rJSP O R i BUPIAL D a, c.

CChPAnf SITE VOLUME MILLICURIES 03, 07/13.'

CN DWS i93.00 32574.00 i/U 2/81 hACKE USE 105.00 1607.00 05,'4 87 TRI STATE BWS 22.50 194295C'O.00 05.<' ; t / 8 ~.

HACdE USE 566.30 1169.00 05/21."37 CN DWS 193.00 29213.00 05/21,'81 NAf TECH SEG 848.60 182.00 a3/28/37 CN LWS 1'73.00 17321.00 x + o... n > + + + e s a n n e e u x e + > x r x x n n n e r e x s n + + + x + w n + + x e s e x x

  • M n x + n e x n n e x w + n + + +

l

10NTHLY TGTALS =

2121.90 105iiS66.00 l

I l

l t.!SE = U.S.

ECOLOGi BSC = BARNWELL JOUTH CAROLINA CN CHEri NUCLEAR CO.

l SEG = SCIEt<TIFIC ECOLOGi GROUP 1

1 l

l l

l l

l l

50

TABLE 2.0-1 (continued)

SOLIO RADIOoCTIVE V6.SiE SUMnARY U rJ I T;; t/2 LUAD GIlit:a STATION l

vL,NE 07

,:n.9.s t R i

..Uf;1 AL

i. :.n f,icW

.TE

/CLUME nILLICURIES U

m mgy E

f l+

g t cv i a, "S T

.s >

DUC

^93 00 14046.00

o/1i 3 7

.J Bus 57.00 0738500.00 06-9/87 C i, 6LS 57.00 7639200.00 06/ 25 / 8 ~/

CrJ aWS 193.00 17967.00 e

  • *t *
  • R * / h n + * * -* P K M M k ? v v er (
  • p e n t e + * +,,
  • M,9 4 g g g g g g 4 g g.( e g, 4 4.,4 4,, g 4, y 4,4,,3 M0tDHL/ ~0TAL, y;3.00 164.'s Ji >-

=

~ 2._ -

L.S.

ECJLOGY JS!

r ant /U 2:L- '/CUiH CAROLINA CHEh NUC'.iAR CO.

en J.2 u

= IC I _N f li-I C ECOLOG 1' GROUP 51

u.:g 4

TABLE 2.0-1-(continued)

SOLID RADI0 ACTIVE WASTE

SUMMARY

UNITS i/2 QUAD CITIES STATION JULY 87 TRANSPORT BURIAL DATE COMPANY SITE VOLUME MILLICURIES 07/10/87 CNSI BSC 120.30 484000.00 07/15/87 TRI STATE BSC 128.30 21272.00 07/17/87 CNSI BSC 120.30 477000.00 07/24/87 CNSI BSC 120.30 110290.00 07/29/07 RAY TECH SEG 1037.20 119.04 07/30/87 CNSI BSC 194.10 14032.90 MONTHLY TOTALS =

1720.50 1114722 (4 USE

= U.S.

ECOLOGY BARNWELL SOUTH CAROLINA BSC

=

CHEM NUCLEAR SYSTEMS INC.

CNSI

=

SEG

= SCIENTIFIC ECOLOGY GROUP i

52

-_--. = m.-

TABLE 2.0-1 (continued)

SOLID RADI0 ACTIVE WASTE

SUMMARY

UNITS i/2 QUAD CITIES STATION AUGUST 87 TRANSPORT BURIAL DATE COMPANY SITE VOLUME MILLICURIES 08/06/87 CNSI BSC 194.10 9995.00 08/07/87 HACKE USE 566.80 1857.50 08/13/87 CNSI BSC 194.1O i0863.00 08/20/B't CNSI BSC 194.10 8012.80 08/27/87 CNSI BSC 194.10 7062.80 08/31/87 CNSI BSC 194.10 14745.20 HONTHLY TOTALS =

1537.30 52536.30 USE

= U.S.

ECOLOGY BSC

= BARNWELL SOUTH CAROLINH CHEM NUCLEAR SYSTEMS INC.

CNSI

=

SCIENTIFIC ECOLOGY GROUP SEG

=

l l

l l

l 1

53

o' TABLE 2.0-1 (continued)

SOLID RADI0 ACTIVE WASTE

SUMMARY

UNITS i/2 QUAD CITIES STATION l

SEPTEMBER 87 TRANSPORT BURIAL

^.DATE COMPANY SITE VOLUME MILLICURIES 09/03/87 CNSI DSC 194.10 20527.70 09/10/87 CNSI BSC 194.10 22039.00 09/17/87 CNSI BSC 205.80 39667.10 09/24/87 CNSI BSC 205.80 27934.00 09/25/87 RAY TECH SEG 1059.70 204.22 l

09/30/87 CNSI BSC 205.80 23331.00 i

l l

l 2065.30 133703.02 MONTHLY TOTALS

=

l USE

= U.S.

ECOLOGY l

BSC

=

BARNWELL SOUTH CAROLINA l

CNSI = CHEM NUCLEAR SYSTEMS INC.

l-SEG

= SCIENTIFIC ECOLOGY GROUP l

1 l

l l

l l

t 54 l

TABLE 2.0-1 (continued)

SOLID RADIOACTIVE WASTE

SUMMARY

UNITS 1/2 QUAD CITIES STATION OCTOBER 87 TRANSPORT BURIAL DATE COMPANY SITE VOLUME MILLICURIES 10/01/87 HACKE USE 564.10 940.41 10/07/87 CNSI BSC 177.50 113229.00 10/19/87 CNSI BSC 205.80 10695.20 10/22/87 RAY TECH SEG 652.50 172.20 10/26/07 CNSI BSC 205.80 24910.00 MONTHLY TOTALS =

1805.70 149946.81 USE

= U.S.

ECOLOGY BARNWELL SOUTH CAROLINA BSC

=

CNSI = CHEM NUCLEAR SYSTEMS INC.

SEG

= SCIENTIFIC ECOLOGY GROUP l

55

~o:

TABLE 2.0-l'(continued)

SOLID RADIOACTIVE WASTE

SUMMARY

UNITS 1/2 QUAD CITIES STATION NOVEMBER 87 l

TRANSPORT BURIAL DATE COMPANY SITE VOLUME MILLICURIES 11/02/87 AJ METLER SEG 1474.40 106.55 11/03/87 CNSI BSC 205.80 52348.00 11/05/87 HACKE USE 450.00 594.67 11/09/87 CNSI BSC 205.80 25271.00 11/10/87 AJ METLER SEG 1290.10 46.90 11/16/87 CNSI BSC 205.80

-18322.00 11/18/87 AJ METLER SEG 1290.10 49.48 11/23/87 CNSI BSC 205.80 11101.00 1

l MONTHLY TOTALS =

5327.80 107839.60 l

[

i USE

= U.S.

ECOLOGY DSC

=

BARNWELL SOUTH CAROLINA CNSI = CHEM NUCLEAR SYSTEMS INC.

l SEG

= SCIENTIFIC ECOLOGY GROUP l

l 56

~

TABLE 2.0-1 (continued)

SOLID RADIOACTIVE WASTE

SUMMARY

UNITS 1/2 QUAD CITIES STATION DECEMBER 87 TRANSPORT BURIAL DATE COMPANY SITE VOLUME MILLICURIES 12/03/87 AJ METLER SEG 1037.20 162.70 12/03/87 CNSI BSC 205.80 50543.00 12/07/87 AJ METLER SEG 1290.10 43.42

^

12/08/87 AJ METLER SEG 754.30 110.13 12/14/87 CNSI BSC 205.80 30145.00 12/17/87 HACKE USE 495.00 557.32 12/21/87 CNSI BSC 205.80 18457.00 12/28/87 CNSI BSC 205.80 15659.00 12/29/87 AJ METLER SEG 1131.50 138.95

. ****************************************************************x*****

MONTHLY TOTALS =

5531.30 115816.52 USE

= U.S.

ECOLOGY BSC

= BARNWELL SOUTH CAROLINA CNSI = CHEM NUCLEAR SYSTEMS INC.

SEG

= SCIENTIFIC ECOLOGY GROUP 4

i 57

FIGURE 3.1-1 10 i"*

Estimated Cumulative Gama Dose (in mrem) /

8g 15 from the Quad Cities Station for the period January-December 1987 15 S0 Isopleth Labels Small figure - multiply by 10-4 I REL ASE M

Large figure - multiply by 10-5 POIIn-

?: h"k l 25

- !\\ Q h3

/.

1s SCALE 9-

' wars 17 "

f O' g 1

C L

I N

T O

j

=

l efu 'oa;-

T

"\\'#

+

t5

  1. 'e,,

25 d

E

[

Chnfon

=

7 1 df h

  • "8 s De Witt o

\\

y, 3a w

.,;N Morrison N

i-_

ors,s.*'c.

t

.'00'

\\

,.* (.

c I.

L L

I N

O I

S,f 1

0'.

V I

1s0 /',

k WH I T E(

l 0 g

ts 50

T **

Q]

oh

~

f.((!

~R,

~

n S

C O

T T I ',

R O C K d

I * "'

15

,o**

w,.....

g

, fil

' mi

i. o

'#4ITN4?Eif5 L(1

~-

1 SLA 0-

.u,,

we Mille

,1 9'd*

H i

N R

Y

'Wf

\\

[

1 dk I...

SCALE 58 9.

..t 9

is to.tri W

'l _ _ J 8' a-

[/

FIGURE 3.1-2

,,6,

Estimated Total Cor centrations (in pCi/m3) of Noble Gases from the Quad Cities Station i

l 40 for the period January-December 1987 75 l

q Isopleth labels 75 I

1.

Small figure - multiply by 10-2 g'

Large figure - multiply by 10-3 l

25

\\

/

SCALE j

y

. ' mia, 4

)

g3 i%'.

f p;

\\

'N l

N T

O N

  • 1 5 ' l ' ' ' ~'~

.WB b-h i

A,i,,.

  • K

.)

., m h o.w...

N u s so m N

F Morrison 400...,I

\\,

'l c, a#es, j aoo s

,p; m

, ~,.

2so

,g g

s i

o w

""Pyy O NI oot _

L L

I N

f f

L s

co_

j fs,.,y D TES DE,-

g t

M n.

15.

cfh,7-S c

u m# % } M J G

.. w.

'y p=h

,ge wd4E

~

i e

,s yA" L

  • y s~ i....,,.-

A SCALE

]

9.

...t

's to mius gg n

  • Qk 4.

FI URE 3.1-3 Estimated Total Concentrations (in pCi/m3)

/

50 "'" [

i f

30 of Iodine from the Quad Cities Station for the period January-December 1987

+

Isopleth labels So small figure - multiply by 10-5 "Ng Large figure - multiply by 10-6 p

f s

/ ao1 m

\\

/

/

20 e

1 SOALE

' uitts w,

4 1

= /, h

'i h5' -

L I

N T

0 N

i 100

[',,

[ k,a L +$,,)*

f

-wl Eg d y

'f o,..,,

^ *.

g

=j=,,,7,-- y4 - N Morri j

amonche aw, p

............+y

,p sw 2

s e

5 L

L N

O 1

S,f i

o 500

/-

e W

IT SI D T

'e

,,g c-

,T a

1 s

U Erie S

C O

T T

R 0 C

,o**

)

w.new.

    • ,, 4' 100

. m i sr a IS A

0'T mgy,in mu o

/J g'aa s s,,

mu w

9 s

.I ShD%'

$N_

s H

N R

Y f

~.

re,,,

Ru te v

.A i... -

'CE 60 o

.p.a,

1

FIGURE 3.1-4 Estimated Total Concentrations (in pCi/m3) of Particulate Matter from the Quad Cities

' [f y f

Stc tion for the period January-December 1987

.. 7 Isopleth labels

/ 00 Small figure - multiply by 10-5 f

A RE large figure - multiply by 10-6 p i g-hk' 1

20

)

e SCALE 9'

I

/

miLas 9

8 3

o..

3

. y

~

C L

I T

O N

I I *' '

4 i

[ T*

"f

,s,on.

f.

,~

e

)

y s 3, y j

De wett vs w 7rw-

/

usno w s

uorr.

so j.., )

\\\\

c s

f f.

gon s<

a..,,,i*'<.. I r,,

(

3 N1

[

~~

1 400 A 800 1E A

I L

1 N

O I

S

{I O

ia W/

/'g'W L*

H TES O E,. '-

M,,

g Nf.

Pr'ya g

q S

C T

T C K N

E' (

y-e 3.....

j ISLA D/--

_p

,9 g,

_n w

e Si,'eF N

R Y

c ai,,

7,gr

.. 2 A

SCALE h

9.

9

'o it to mitts 61 l

n n

n n

o m

m.m

.g TABLE 3.1-1 CUAD CITIES UNIT ONE 1987 ANNUAL REPORT wax!WUW 00$ES RESULT!NG FROW AIR 80RNE RELEASES PERIOD OF RELEASE - 01/01/87 TO 12/31/87 CALCULATED 04/12/88 1sT 2ND 3RD 4TH TYPE QUARTER QUARTER CUARTER OUAATER

/,NNUAL J;N-WAp APR-J N JUL-SEP OCT-DEC GAWWA AIR 3.31E-03 1.24E-03 6.15E-04

  • 1.68E-04 5.24E-03 (WRAD)

(WNW )

(W

)

(W

)

IW

)

(WNW )

8 ETA AIR 5.73E-03 6.49E-04 1.88E-04 4.11E-05 6.57E-03 (WRAD)

(WNW )

(NW )

(NW )

(NW )

(NW )

707 80DY 1.55E-03 6.30E-04 2.97E-04 9.05E-05 2.52E-03 (WREW)

(WNW )

(W

)

(W

)

(W

)

(WNW )

SKIN 6.78E-03 1.37E-03 6.01E-04 1.60E-04 8.88E-03 (WREW)

(WNW )

(NW )

(W

)

(W

)

(WNW )

ORGAN 1.47E-02 5.12E-02 2.69E-02 2.39E-02 1.16E-01 (WREW)

(WNw )

(WNW )

(WNW )

(WNW )

(WNW )

TMvROID THYR 0!D THYROID LUNG THYROID

)

THIS 45 A REPORT FOR THE CALENDAR YEAR 1987 COMPLIANCE STATUS - to CFR 50 APP. !


 % OF APP !. -------------

QTRLY 1ST OTR 2ND OTR 3RD OTR 4TH CTR YRLY

% OF 08J JAN-WAR APR-JUN JUL-SEP OCT-NOV 08J APP.!

GAWWA AIR (WRAD) 5.0 0.07 0.02 0.01 0.00 10.0 0.05 SETA AIR (WRAD) 10.0 0.06 0.01 0.00 0.00 20.0 0.03 TOT. 800v (WREW) 2.5 0.06 0.03 0.01 0.00 5.0 0.05 SKIN (WREW) 7.5 0.09 0.02 0.01 0.00 15.0 0.06 ORGAN (WREW) 7.5 0.20 0.68 0.33 0.32 15.0 0.78 THYROID THYR 0!D THYROID LONG THYROID RESULTS BASED UPON 00CW REVISION 11 UPDATE CS118 FE8RUARY 1986 62

f-TABLE 3.1-1 (continued) t OUAD Clt!ES UNIT Two 1987 ANNUAL REPORT wax!WuW 00SES RESULTING FROW AIRBORNE RELEASES PERIOD OF RE!. EASE - 01/01/87 TO 12/31/87 CALCULAf?.D 04/12/88 IST 2ND 3RD 4TH l

TYPE OVARTER OVARTER OVARTER OUARTER ANNUAL JAN-WAR APR*JllN JUL*SEP OCT-DEC GAWWA AIR 2.02E-03 1.21E-03 6.15E-04 2.41E-04 4.OTE-03 (ePAD)

(W

)

(W

)

(W

)

(WNW )

(W

)

SETA AIR 9.02E-04 4.70E-04 1.8BE-04 3.32E-04 1.89E-03

-(WRAD)

(NW )

(NW )

(NW )

(WNW )

(NW )

TOT. 800Y 1.04E-03 6.21E-04 2.97E-04 1.20E-04 2.07E-03 (WREM)

(W

)

(W

)

(W

)

(WNW )

(W

)

$ KIN 2.19E-03 1.25E-03 6.01E-04 4.40E-04 4.46E-03 (WREW)

(NW i (NW )

(W

)

(WNW )

(NW )

ORGAN 7.98E-02 2.55E-02 1.93E-02 2.43E-02 9.89E-02 (WREW)

(WNW )

(WNW )

(WNW )

(WNW )

(WNW )

THYR 010 THYR 010 THYRCID THYROID THYR 010 THIS 15 A REPORT FOR THE CALENDAR YEAR 1987 COMPLIANCE STATUS - 10 CFR 50 APP. !

7


 % OF APP 1,.

OTRLY 1$7 OTR INO OTR 3RD OTR 4TH OTR VRLY

% OF i

08J JAN-W.'R AOR-JUN JUL-5EP OCT-NOV OBJ APP.!

GAMWA AIR (WRAD) 5.0 0.04 0.02 0.01 0.00 10.0 0.04 SETA AIR (WRAD) 10.0 0.01 0.00 0.00 0.00 20.0 0.01 TOT. BODY (WREW) 2.5 0.04 0.02 0.01 0.00 5.J 0.04 SKIN (WREW) 7.5 0.03 3.02 0.01 0.01 15.0 0.03 ORGAN (WREW) 7.5 0.40 0.34 0.26 0.32 15.0 0.66 THYR 010 THYR 010 THYR 0!O THvROID THYR 010 RESULTS 8ASED UPON ODCW REVISION 11 UPDATE CS118 FEBRUARY 1986 i

i e

63 a

a TABLE 3.2-1 QUAD CITIES UNIT ONE 1987 ANNUAL REPORT WAXIMUW DOSES (WREW) RESULT!NG FROM LIQUID EFFLUENTS PERIOD OF RELEASE - 01/01/87 TO 12/31/87 CALCULATED 04/12/88 IST 2ND 3RD 4TM 005E TYPE QUARTER OVARTER QUARTER QUARTER ANNUAL JAN-MAR

.APR=JUN JUL-SEP OCT-DEC TOTAL 2.08E-04 2.54E-04 3.64E-04 0.85E-04 1.72E-03 SODY INTERNAL 3.15E-04 3.91E-04 5.50E-Od 1.36E-03 2.61E-03 ORGAN LIVER LIVER LIVER LIVER LIVER TMIS !$ A REPORT FOR THE CALENDAR YEAR 1987 COMPLIANCE STATUS - 10 CFR 50 APP. I 0

g


%OFAPP1.-------------

QTRLY IST QTR 2ND QTR 3RD QTR ATH QTR VRLY

% OF OBJ JAN-WAR APR-JUN JUL-$EP OCT-NOV OBJ APP.!

TOTAL BODY (WREW) 1.5 0.01 0.02 -

0.02 0.06 3.0 0.06 CRIT. ORGAN (WREW) 5.0 0.01 0.01 0.01 0.03 10.0 0.03 LIVER LIVER LIVER LIVER LIVER RESULTS BASED UPON ODCW REVISION 11 UPDATE CS114 FEBRUARY 1986 5

64

.+

=.

pg s.

TABLE 3.2 1 (continued)

+

1 QUA0 CITIE$ UNIT Two 1987 ANNUAL REPORT wax! MUM DOSES (WREM) RESULT!NG FROM LIQUID EFFLUENTS PERIOD OF RELEASE - 01/01/87 TO 12/31/87 CALCULA'IED 04/12/88 1ST 2ND 3RD 4TH 00$E Type QUARTER QUARTER QUARTER OVARTER ANNUAL

-JAN-MAR APR-JUN JUL*SEP OCT-DEC 1.68E-04 2.58E-04 1.78E-04 4.36E-04 1.04E-03 TOTAL 800Y 2.55E-04 3.91E-04 2.68E-04 6.67E-04 1.58E-03 j

INTERNAL LIVER LIVER LIVER LIVER LIVER THgs is A REPORT FOR THE CALENDAR YEAR 1987 6

i COMPL!ANCE $TATUS - 10 CFR 50 APP. 1

............. % OF AP> !. -*------*==*-

QTRLY 15T QTR 2ND QTR 3RD QTR 4TH QTR VRLY

% OF OBJ JAN-WAR APR=JUN' JUL-5EP OCT-NOV 08J APP.!

TOTAL 800v (MREW) 1.5 0.01 0.02 0.01 0.03 3'C 0 0" CRIT. CRCAN(wREM)- 5.0 0.01 0.01 0.01 0.01 10.O 0.02 LIVER LIVER LIVER LIVER LIVER i'

RESULTS SA 'ED UPON ODCM REV!$10N 11 UPDATE C5118 i

FEBRUARY 1986 J

65

, _., - ~, -..,,. - _. -. _ ~ - - - - -. -,. - - -. ~,

,,m.

1 Figure 5.0-1 DECEMBER '3E5

(

~

,......i...

m., e, i

s' Fulton Clinton a

^

us 2:

usso 7

f Y

15Md 16e moi.i ron.

ril in3 2's e ed

,,2,o 2, '

2 t

ais..,

to,.

Illinois lowa 2'52 si.'.'ije 2o4-e8

.4 2..:

" " ' '4

.*1

< 1,4 333.,

2 si s.'

3 res.:

zia. n ro6.i es mio..

sia.im,,,,,

US 61 3

52o71 1

O f(,nos.o7 2 '-

52 2.

2 i

roi.i l

2ot.:

iLL 2 1

I 119 i.so DSVenpOd US 67 Rock River fg'2

[

f k\\

44 iLL 2, me 1_-

a es

+

/

l ss i

we, e Air S mphng Site 5 Outer Ring TLD Location i.7.

s.ao 0

,,5 i,o i,5 2,o Mile,

$c ele j

o 5

to il no 25 3o hm QU.\\D CITIES STATION Units 1 A. 2 FIXE 0 AIR SAMPLING SITES AND OUTER RING TLD LOCA1!ONS 66 ils'i'-112

Figure 5.0-2 CECE:'EE:. : Hi y/

/

, e,, u,./4, /' /.

6 116 2 g

1

/

sent.oer/l

+f /, +'?../

it f

.sy,,;;,//,.!

us1 a u s.,

~ h p'/ r'. A, # m

,,,2.,

/

r/

p. -

/, lCamanche j,,/

7, p

.S 31142 f

  • /

{

f fj"lf$[*

~

(l

/e p

//

g Clintoncounty cm

}l

/s

\\. u$,/

3 114 1

/

51012 u

r,"

'03 '

/

A*k Il

\\.

'/

E'0

f('"pl k.}h, j.

g ig4.

m

\\

j ji iog

'p r

./s..)

uits 2 /

l

  • I Quad-105 1 i n' ma. ;eCities

[

3 3 3,,

Station s.

./

g i

g y

,f too 2 B 1131 i

T 7.

7

\\

/

l ior.i

/

/

\\

5 i

,j

!./

.'[e/

5 s

tor.

11225

,...'1 173 3.

.f g g.., $* y, 1.

j us., a f

io. 2 3

.ij J!

's ; \\

\\

,/

/.hx.s =j l I i'l

/

I ut.: a S

i i

!. i l l

' n ' i..

-. -Q

}

i.

/,/,

1 Princeton l

/

l

/

)

l

}

'~

d bS.k e

,'/

g q

lows /

l e

h.

tam

/lilinoist s"*

QU AD-CITIES STATION l *"'

Units 1 4. 2 9_

o al ihm If4NER RING TLD LOCATIONS 67

' - 3'8

O Figure 5.0-3 A

ECE"EE: 1 V,5 p,,,,,,,,k iowa i3e c ose u,

us 67

't a'"'

' iu s.

Clinton us si l

IOWA 13e us er

'/

Fulto,n-caNw

,u 7, Clinto DeWitt

)

)

us so Q es

_ua 7; c, g, w Morrison arnancne

aiun, w.oi...n.c n n,n, 17 j

itt is

- e a 22,21 a

lilinois lowa Whiteside custeam i

D ~ Core 1 ova

.13 en. on us at Scott y o,,,,,

Hiiis a.i.

sN

\\

f

' Port syton

/

%k J

lsland

~~

j Davenport 23 24 (

/

Hornplon 20 m

enene RN y

Henry nun 3g oline

'l (r.i..[

enig, r

a Sampling Station a

se.i.

l

?,,,,?

'?

'?

rp uan u,,,5

'?

'?

2?

2?

2? "

o QUAD-CITIES STATION Units 1 & 2 f1 ILK, FISH, WATER, AND SE0!ttEfli SAMPLE LOCATIONS iTA#

68

- r;

Table 5.0-1 F

QUAD CITIES NUCLEAR POWER STATION i

STANDARD RADIOLOGICAL SMPLING PROGRM Media I

s.

C 2

E

'i 9

a I

3 u

m 3

.w % %

m Location Location g

Code Typea Location Description h g j j j ] { j Q-01 On-site No.1 X

X i

X X

-02 On-site No. 2 X

X

-03 On-site No. 3 X

X

-04 Nitrin X

X

-05 Saddle Club

-06 Hanson's Boat Landing X

X

-07 Clinton X

X

-08 Sikkema Farm X

X

-09 C

Erie X

X

-10 C

Hillsdale X

X

-11 Port Byron X

X

-12 Bettendorf X

X

-13 Princeton X lX

-14 C

Utica Ridge Road X

X

-15 C

DeWitt X

X

-16 C

Low Moor X

X

-17 C

Hansen Dairy Farm X

X

-18 Musal Farm X

X

-19 East Moline Water Werks X

4 C Davenport Water Works X

-20 C

Inlet Canal X

-21 Discharge Canal X

j

-23 Lock and Dam No. 14 (Mississippi River)

X

-24 Davenport Fish Market (Pool i

No.14, Mississippi River)

X l

Control (background) locations are indicated by a "C" in this coluan, j

a All other locations are indicators.

I 69

._ ~.._ _ __.-- _.--_._ ___.-,_,. _ _

4 Table 5.0-2 QUA0 CITIES STATIC'i

!NVIR0W. ENTAL RADIOLOGIAL MONITORING PROGRM, SMPLING LOCATIONS 1.

AIR SMPLERS Distance Direction Site Codea Location (miles)

(*)

Q-01 a.

On-site Station No.1

0. 5 0

Q-02 b.

On-site ~ Station No. 2

0. 5 70 Q-03 c.

On-site Station No. 3

0. 6 170 Q-04 d.

Nitrinite No. 4

1. 5 40 Q-05 e.

Saddle Club Dairy Farm

1. 8 160 Q f.

Hanson's Boat Landing

1. 8 340 Q-07 C) 9 Clinton
9. 0 40 0-03 C) h.

Sikkema Farm

7. 0 70 Q-09 C) 1.

Erie 13.0 110 Q-10 C) j.

Hillsdale 10.0 130 Q-11 k.

Port Byron

8. 0 170 Q-12 1.

Bettendorf 13.0 218 Q-13 m.

Princeton

4. 8 220 Q-14 n.

Utics Ridge Road 11.0 270 Q-15 c.

DeWitt 13.0 300 Q-16 p.

Low Moor

6. 0 330 2.

TLDs a.

Same as No. 1.

b.

Special TLD Sanplers Distance Direction Revised Site Codeb Previous Site Code (miles)

(*)

Q-101 1,2 Same

0. 7 4

Q-102 1,2 Same

1. 7 21 Q-103 1 Same
1. 2 58 Q-104 1 Q-103 2 1.1 60 Q-104 2 Q-104 1 0.95 77 Q-104 3 Q-104 2 0.63 77 Q-105 1 Same 0.75 91 4

Control (reference) locations are denoted by a "C" af ter site code.

All a

i other locations are indicators.

b Effective August 1,1985.

l 70

~

Table 5.0-2 (continued)

QUAD C! TIES STATION ENVIRONMENTAL RADIOLOGIAL MONITORING PROGRN1, SAMPLING LOCATIONS 2.

TLDs b.

Special TLD Samplers (continued)

Distance Direction Revised Site Code Previous Site Code (miles)

(*)

Q-106 1 Q-105 2 0.71 109 Q-106 2 Q-106 1 0.71 118 Q-107 1 Q-106 2 0.71 128-Q-107 2 Q-107 1 0.73 137 Q-107 3 Q-107-2 0.78 146 Q-108 1,2 Same 0.9 155 Q-109 1,2 Same 0.95 176 Q-111 1,2 Same

2. 6 230 Q-112 1,2 Same 2.4 246 Q-113 1,2 Same 2.5 264 Q-114 1,2 Same
2. 6 286 Q-115 1,2 Saire
2. 3 310 Q-116 1,2 Same
2. 2 339 Q-201 1,2 Same 4.0 356 Q-202 1,2 Same 4.4 17 Q-203 1,2 Same
5. 5 34 Q-204 1,2 Same
4. 5 61 Q-205 1,2 Same 4.5 83 Q-206 1,2 Same 4.8 113 Q-207 1,2 Same 4.8 133 Q-208 1,2 Same 4.4 158 Q-209 1,2 Same 4.8 179 Q-210 1,2 Same 4.4 210 Q-211 1

Same

5. 0 223 Q-212 1,2 Same 4.8 242 Q-213 1,2 Same 4.7 265 Q-214 1,2 Same 4.8 310 Q-215 1,2 Saoe
4. 8 316 Q-216 1,2 Same 4.5 333 3.

MILK Distance Direction Site Codea Location (miles)

(*)

Q-17 (C) a.

Hansen Dairy Farm

6. 0 70 Q-18 b.

Musal Farm

5. 5 225 a Control (reference) locations are denoted by a "C" af ter site code.

All other locations are indicators.

71

u-L P

Table 5.0-2 (continued)

QUAD CITIES STATION ENVIR0* ENTAL RADIOLOGIAL MONITORING PROGRAM, SMPLING LOCATIONS 4.

PUBLIC WATER SUPPLY Distance Direction 1.

Site Codea Location (miles)

(*)

E.

Q-19 a.

East Moline Water Works If. 0 206 Q-20(C) b.

Davenport Water Works 18.0 219 5.

COOLING WATER Distance Direction Site Codea Location (miles)

(*)

r Q-21(C) a.

Inlet At Station Q-22 b.

Discharge l

[

6.

FISH l

i Distance Direction i

Site Codea Location (miles)

(*)

l Q-24.

Davenport Fish Market Pool No.14 of Mississippi f

River c

7.

BOTTOM SEDIMENTS Distance Direction Site Codea Location (miles)

(*)

Q-23 Lock and Dam No.14 15.0 210 I

  • Control (reference) locations are denoted by a "C" af ter site code.

All other locations are indicators.

[

t I

t 72

I~

l QUAD CIT" 5 STATION TABLE E-1 ENVIRONMENTAL RADIOLOGICAL N0mITORING PROGRAM. SAMPLE COLLECTION AND ANALYSES tocat1on Collect 1on Type of Frequency sample Media Codes

_ Site Frequency Analysis cs Analysts Aemarks 1.

Airborna a.

Onstte and Near Field Cor.s tnuous Gross beta Weekly On all samples.

Particulates oppretton Gasmaa Isot if gross beta in a sample Q-1 Onstte Mc. I for one exceeds by 5X the average concentration of Q-2 m stte No. 2 week.

the precedM calendar quarter for the Q-3 Onsite No. 3 sample location.

Q-4 N1trin Non-routine Reporting tevelsh 0-5 Saddle Club Dairy Fare Cs-134 10. Cs-137 20 pct /m3 Q-6 Hanson's Boat Landing

.t b.

Far Field Same as la.

Filter ideekly Non-routine Reporttaa tevelsh Enchange Q-7 (C)

CMnton Same as 1(a) when analyses are made.

y u

0-8 (C) sikkona Farm G 9 (C)

rte 0-10 (C)

Hillsdale 0-11 (C)

Port Byron 0-12 (C)

Bettendorf Q-13 (C)

Princeton Q-14 (C)

Utto a.dge Itoad Q-15 (C)

DeWitt 0-16 (C)

LSw Moo-2.

Airborne same as 1.

Continuous I-131 81 weekly 81 weekly - Every two weeks.

Iodine operation On all samples for tuo weeks Non-routine Reporting Levelb 0.9 pct /m3 Test and Weekly On all sanplers.

3.

Air Sampilng same as 1.

Train Maintenance l

  • Control (reference) locations are denoted by a "C" in this column. All other locations are indicators.

Averepa concentration over calender quarter.

C wew.-,.

-_--w%

e-a,,_,

--v-*

e.

,.,.g

.w,,

.u

~

.c Table 5.0-2 (continued)

QUA0 CITIES STAT 10N ENVIR0eMENTAL RADIOLOGICAL MohlTORInG M0 GRAM. 54tPLE COLLCCI!ON AND AhALY$E$

Location Collettlon ype of F:equency Souple Media Code

  • 54te frequency Analyst 5 of m alysis Menarks 4

TLD Q-101 1.2 Inner Ring Werterly Gamma (Marterly Two sets at all A* iocations. the set 102 1.2 read quarterly. Second set read if required 103 1 by Commonwealth Edison. At other loca.

104 1.2.3 tions, all sets read quarterly. mtatswa 105 1 of two ILDs per set.

106 1.2 107 1.7.3 108 1.2 109 1.2

[ through 111 1.2 116 1.2 L-201 1.2 (hter Ring y

A through 210 1,7 l

211 212 1.2 through 215

1. 2 5.

Milk Q-17 (C)

Mansen Dairy Weekly:

jl.131 Weekly:

(h all samples. LLD: 0.5 pct /I.

Q-18 Musal Farm May through May through October October Monthly:

1-131 v40nthly:

(h all samples. LLD:

5.0 pct /l.

-j moves 6er hovember through through j

April April l

Non-routine Reporterg tevelsh I-131 3: Cs-134 60; Cs-137 70; 8a-La-140 300 pct /I

  1. Control (ref erence) locations are denoted by a "C" to this cclumn. All other locations are Indicators.

Avera y Concentration over Calend4r year.

1 7

Table 5.0-2 (continued)

QUA0 CITIES STATION ENVIR0etENTAL RADIOLOGICAL MONITURING PROGR* SAMPLE COLLECTION Amu ANALYSES

/

Location Collection Type of Frequency Sag le Media todes Site Frequency Analysts of Analysts Remarks 6.

Public Water Q-19 East Moline Water Weekly Gesuna Isot Monthly ei monthly composite from each location.

Works G-20 (C)

Davenport Water Works Non-routine Neporting Levelsh (See f ootnote "c.")

7.

Cooling Water Q-21 (C)

Inlet Canal Weekly Gross beta nieekly On notif Ication provided by station Q-22 Discha ge Canal personnel, y

as 8.

Fish Q-24 Pool 14 of Mississippt Sealannually Garma Isot Sealannually on edible portions only. At least two River species.

Non-routine Neporting levelsD j

4 4

ph-54 A10 ; Fe-591:10 ; Co-58 A104 4

4 3

Co-601 10 - Zn-65 2x10 ; Cs-1341:10 ;

I 3 ;1/kg eset iseight, j

l Cs-131 1:10 p

i i

9.

80ttom Q-23 Lock and Dao 88o.14 Annually Gassna Isot Annually I

5ediments f Control (reference) locations are denoted by a *C" in this column. All other locations are Indicators.

Average concentration over calendar year.

3 3

2 2

2 2

2 2

C H-3 2m10. Mn-54 1:10. Fe-59 4x10. Co-58 1:10. Co-60 h10, zn.65 kl0. Zr-IR>-95 4ml0.1-131 2. Cs-134 30. C5-137 50. Sa-La-140 2x10 pelf t,

.C

s s

c Table 5.0-2 (continued)

QUAD CIT!U STATitA ENVIRosmENTAL RADIOLOGICAL MONIl0 RING PROGtM. SAPPLE CULLECTION AND ANALYSES (continued) location Collection Tpe of Frequency Saaple Media Code Site Frequency Antlysis of Analysts Nemarks a.

Enumeration by a door-Annually During grazing season.

10. Dairy Census a.

Site boundary to 2 miles to-door or equivalent counting technique.

b.

Enumeration by using Annually During grazing season.

b.

2 miles to 5 miles referenced inf ormation from county agricultural agents or other reliable sources.

C.

At detries listed in Item 5.

c.

Inquire as to feeding Annually thering grazing season.

y Os practices:

(1) Pasture only.

(2) Fe:S and chop only.

I (3) Pasture and feed; if both, ask farmer l

to es' mte fraction i

of food f rom pasture:

<2',1,25-501, 50-75%,

or >15%.

11. Nearest In all 16 sectors Annually Residence Census a

I

i TA8LE 5.0-3 ENVIR0eMENTAL RADIOLOGICAL MONITORING PROGRAM QUARTERLY SteetARY Name of Factifty Quad Citfes thsclear Power Station Docket Iso.

50-254. 50-265 Location of Factitty Rock Island, Illinois Reporting Period 1st Quarter 1987 (County, Statel Indicator Location with Highest Control Sample Type and Locations Quarterly Mean Locations Ilue er of Type tsumber of Meen" Mean Meena Ison-routt ne (Units)

Analyse.

LLD Range Location Range Range Results i

l Afr Particulates Gross Beta 72 0.01 0.024 (71/72) 0-06. Hanson's 0.026 (12/12) tiene 0

.f (0.019-0.036)

(pCf/m3)

(0.010-0.038)

Se,a,t Dock, 1.8 340-l Airborne Iodine I-131 36 0.10

<LLO Isone 0

l (pCf/m )

{

3 15.5 (1/1) 12.8 (10/101 0

y Gaiana Background Ga ma Dose 16 3.0

f. 2 (6/6) 0-11, Por.t Byron (9.9-15.51 8.0 at 170*

(TLDs) (mR/Qtr.)

(10.8-13.9) 1 ptilk 1-131 6

5.0

<tLD none 0

(pCf/1)

Cooling Water Gross Beta 28 2.0 3.2 (14/i4)

Q-22A, Diffuser 3.2 (14/14) 2.8 (14/14) 0 (pCf/1)

(1.7-4.8)

Pfpe Slowdown (1.7-4.8)

(2.1-3.6) at Station Trittum 1

200 622 (1/1)

Q-22A, Diffuser 622 (1/1)

None O

Pfpe Blowdown at Station Pubitc Water Gamma spec.

6 (PCl/1)

Cs-134 10.0

<tLD hone O

Cs-137 10.0

<LLD hone 0

Other Games 20.0 (LLD hone 0

  • Mean and range based on detectable measurements only. Fractions indicated in parentheses.

c e

.m___=.mm___ _. _ _ _ _ _

.___m_

m

e TABLE 5.0-4 4

ENVIROIsCTAL RAD 120GICAL MoulTORING PROGRAM QUARTERLY sisosuty Name of Facility Quad Cf tfes nuclear Power Station Docket No.

50-254, 50-265 Location of Facility _ Rock Island, Illinois Reporting Period 2nd Quarter IM I (County, State)

Indicator Location with Hfghest Control Sample Type and Locations Quarterly Mean Locations number of Type Number of Meena Mean Meena non-routine (Units)

Analyses LLD Range Location Range Range Results Air Particulates Gross 8 eta 78 0.01 0.020 (78/78)

Q-06, Hanson's 0.021 (13/13)

None (pCf/m3)

(0.009-0.035) 8 eat Dock (0.012-0.034) 1.8 el 9 340*

Afrborne lodine I-131 42 0.10 (LLD None 0

(pCf/m3)

Gamma Background Gamma Dose 16 3.0 15.5 (6/6)

Q-19 Port Syron 19.1 (1/1) 15.8 (10/10) 0 (TLDs) (udt/Qtr.1 (13.8-1F.5) 8 at 9 170*

(13.8-19.1)

Rilk 1-131 20 5/0.5b (LLD

<LLD 0

(pCf/3)

M Cooling Water Gross 8 eta 26 1.0 3.8 (13/13) 0-21 Inlet Canal 3.8 (13/13) 3.8 (13/13) 0 (pCf/1)

(2.1-6.3) at Stat 8aa (2.6-5.2)

(2.6-5.2)

Trit 1um 1

200

<LLD None O

Pubile Water Gamma spec.

6 (pCf/1)

Cs-134 10.0

<LLD None O

Cs-137 10.0

<tLD None J

Other Gennes 20.0

<tLD Noept 0

Ffsh Gamma Spec.

4 None O

Cs 134 0.1

<tLD Cs-137 0.1

<tLD None 0

Other Gennes 0.2 (LLD hone 0

a Mean and range based on detectable measurements only. Fractions Indicated in parentheses.

b movember - April LLD = 5.0; May - October LLD = 0.5.

EU l

TABLE 5.0-5 LNVIRONMLNTAL RADIOLOGICAL MONITOR 1dG PROGRAM QUARTLRLY 5tp9tARY Name of Factitty Quad Cities Nuclear Power Station Docket No.

50-254, 50-265 Location of Fact 1TEy Rock Isiano, liisnols Reporting Period Jrd Quarter I C (County, State)

Indicator Location with Highest Control Sample Type and Locations Quarterif Mean Locations kadier of Type Number of Meana Mean Mean8 Non-routine (Units)

Analyses LLD Range Location Range Range Results i

l Air Particulates Gross Beta 78 0.01 0.022 (78/18)

Q.02, Onsite St.

0.025 (13/13)

None 0

(pct /m )

(0.010 0.044)

  1. 2, 0.5 at 0 (0.016-0.0443 J

70*

l Afrborne Iodine I-131 36 0.10

<tLD None 0

3 (pCf/m )

4 Gesuna Background Gawuna Dose 16 3.0 13.3 (6/6)

Q-11, Port Byron 16.9 (1/1) 14.0 (10/10) 0 1

(TLDs) (mR/Qtr.)

(11.8-15.0) 8 0 mi e 170*

(10.9-16.9)

Milk 1-131 24 0.5

<tLD None 0

(pC1/1)

Cooling Water Gross Beta 24 1.0 3.7 (12/12) 0-21, Inlet at 4.1 (12/13) 4.1 (12/12) 0 (pC1/1)

(2.1-5.2)

Station (2.7-5.1)

(2.7-5.1)

Tritfum 1

200

<tLD None O

Pub 1fc Water Ganssa Spec.

6 (pCf/1)

Cs-134 10.0 (LLD None O

Cs-137 10.0

<tLD None 0

Other Ganssas 20.0

<LLD None 0

Bottom Sediments Casana spec.

1 (pCf/g dry)

Cs-134 0.1

<tLD None O

Cs.137 0.1 0.12 (1/1)

Q.23 Lock and 0.12 (1/1)

None 0

Das No. 14 15.0 ml 9 210*

Other Gassmas 0.2

<tLD l

kone 0

a Mean and range based on detectable measurement; only. Fractions indicated in parentheses.

O O

TABLE 5.0-6 ENVIR0stENTAL RADIOLOGICAL stou1TORING PROGRmt QUARTERLY StsoulRY l

tease of Factitty Quad Cities nuclear Power Station Docket me.

50-254, 50-265 l

Location of Factitty Rock Island, Illinois Repcrting Period 4th Quarter 1957 Rounty, 5 tate)

Indicator Location with Highest Control Sample Type and Locations Quarterly Mean Locations munber of Type humber of Meena y,,,

%,a n,_,,,gg (Units)

Analyses LLO Range Location Range Range Results Air Particulates Gross Beta 78 0.01 0.028 (78/78) 0-03, Onstte St.

0.030 (13/13) mone 0

(pct /pr )

(0.009-0.048)

  1. 3. 0.6 at 9 170*

(0.013-0.048) 3 None 0

Airborne lodtne 1-131 36 0.10

<LLD 3

(pC1/m )

Gaassa Background Gasona Dose 16 3.0 14.2 (6/6)

Q-12 Bettendorf 16.7 (1/1) 14.8 (10/10) 0 (TLDs) (mR/Qtr.)

(13.8-11.2) 13.0 et 9 218*

(13.2-16.7) b

<tLD None 0

Milk 1-131 14 5.0/0.5 (pC1/1)

Cooling Water Gross Beta 28 1.0 3.3 (14/14)

Q-21, Inlet Canal 3.5 (14/14) 3.5 (14/14) 0 (pC1/1)

(2.5-4.4) at Station (2.7-4.3)

(2.7-4.3)

Tritium 1

200

<LLD hone O

CD O

Pubite Water Gaassa Spec.

6 Cs-134 10.0

<tLD None O

Cs-137 10.0

<tLD None 0

Other Gammas 20.0

<tLD None 0

Fish Gammma Spec.

4 Cs-134 0.1

<tLO None O

Cs-137 0.1

<LLD home 0

Other Gamunes 0.2 (LLD home 0

  • Mean and range based on detectable measurements only. Fractions indicated in parentheses.

moves 6er - April LLO = 5.0; May - October LLat = 0.5.

l l

l l

7- -

y s'

Table 5.1-1 GAMMA RADI ATION AS MEASURED BY THERM 0 LUMINESCENT DOS! METERS (TLDs)

STANDARD RADIOLOGICAL MONITORING PROGRAM 1st Quarter 2nd Quarter

,3rd Quarter 4th Quarter Date Placed:

01-01-87 03-27-87 06-27-87 10-03-87 Date Removed:

03-27-87 06-27-87 10-03-87 12-30-87 Days in the Field:

85 92 98 88 Location Average mR/ Quarter On-Site Indicator Locations Q-01 On-Site No. 1 11.710.3 15.510.8 13.310.9 13.8i0.8 Q-02 On-Site No. 2 11.710.4 15.210.4 12.4i0.6 14.511.4 Q-03 On-Site No. 3 12.310.4 15.3tl.0 13.9f0.6 13.810.5 Mea, i s.d.

11.910.3 15.310.2 13.210.8 14.010.4

,0ff-Site Indicator Locations Q-04 Nitrin 10.810.3 13.810.8 11.8i0.7 13.9tl.4 Q-05 Saddle Club Dairy 12.6t0.5 15.5i0.6 13.410.6 14.110.4 Q-06 Hanson's Dock 13.910.6 17.510.6 15.0il.1 15.210.4 Mean i s.d.

12.4tl.6 15.6tl.8 13.411.6 14.410.7 Background Locations Q-07 Clinton 12.810.3 15.210.5 13.510.7 14.210.5 Q-08 Sitkema Farm 12.810.6 15.810.9 14.911.1 14.510.4 Q-09 Erie 12.li0.4 14.710.5 13.Dio.8 13.210.5 Q-10 Hillsdale 13.510.5 16.810.6 14.7*0.8 14.9*0.8 Q-11 Port Byron 15.510.7 19.110.6 16.911.2 16.511.2 Q-12 Bettendorf 15.210.3 17.410.5 16.5i0.7 16.710.8 i

Q-13 Princeton 12.310.7 14.7t0.5 13.4i0.6 14.510.7 i

Q-14 Utica Ridge Road 12.210.3 14 400.6 13.110.7 14.210.7 Q-15 DeWitt 9. 91 0. 5 13.810.9 10.911.3 15.011.8 Q-16 Low Moor 12.010.7 15.1i0.5 13.0i0.8 14.610.5 l

f Mean i s.d.

12.8tl.6 15.811.6 14.011.8 14.8tl.1 81 i

D Table 5.1-1 (continued)

GAMMA RADIATION AS MEASURED BY TL0s (continued)

SPECIAL PROGRAM Inner Ring, Near Site Boundary, Indicator locations 1st Quarter 2nd Quarter

- 3rd Quarter 4th Quarter Date Placed:

01-01-87 03-27-87 06-27-87 10-03-87 Date Removed:

03-27-87 06-27-87 10-03-87 12-30-87 Days in the Field:

85 92 98 88 Location Average mR/ Quarter Code Q-101-1 10.6t0.5 14.5*0.7 11.5*1.0 13.310.8 Q-101-2 12.1*1.0 13,710.5 12.510.9 13.411.2 Q-102-1 10.310.4 16.li0.7 11.410.6 15.7tl.1 Q-102-2 12.410.3 13.4i0.4 13.110.7 13.310.7 Q-103-1 9.110.5 15.0t0.9 9.910.7 13.410.5 Q-104-1 9.210.4 13.1*0.8 9.510.6 12.410.4 Q-104-2 11.510.5 13.010.4 13.3fl.2 12.710.4 Q-104-3 12.810.3 13.3i0,5 13.7t0.7 12.610.8 Q-105-1 9.610.4 13.210.9 10.8t0.6 12.910.5 Q-106-1 9.410.5 14.li0.6 10.7t0.7 13.7t0.6 Q-106-2 10.310.8 13.710.7 10.610.6 13.110.6 Q-107-1 9.lt0.4 13.110.4 10.110.7 14.510.8 Q-107-2 10.210.3

13. 9t0. 6 11.710.7 12.8f0.6 Q-107-3 12.3t0.3 12.410.7 12.310.7 11.810.6 Q-108-1 9.110.3 13.110.8 10.011.0 12.810.8 Q-108-2 9.310.3 12.510.6 10.210.6 12.310.4 Q-109-1 9.410.3 15.0t0.7 10.410.6 12.710.4 Q-109-2 11.2i0.4 13.410.5 11.6i0.6 12.510.5 Q-111-1 12.410.4 17.2t0.6 13.611.0 15.0f0.5 Q-111-2 12.910.3 14.110.4 14.010.9 13.510.6 Q-112-1 12.010.2 15.410.7 14.010.8 14.2t0.4 Q-112-2 13.910.3 15.7 0.4 15.1*0.7 15.010.6 Q-113-1 10.810.4 14.910.6 12.410.7 13.0t0.4 Q-113-2 12.5i0.2 12.9t0.5 13.6t0.8 13.210.8 Q-114-1 10.810.9 15.li0.3 11.710.6 14.0f0.8 Q-114-2 11.810.2 12.710.6 12.810.6 12.310.6 Q-115-1 10.410.3 15.7*0.5 10.510.7 13.6i0.8 Q-115-2 13.310.3 15.910.9 13.7t0.9 14.910.6 Q-116-1 11.010.4 16.410.6 12.210.8 Missing Q-116-2 10.810.3 13.710.7 11.210.8 13.710.6 Mean i s.d 11.0tl.4 14.211.3 11.911.5 13.410.9 82

Table 5.1-1 (continued)

GAMMA RADIATION AS MEASURED BY TL0s (continued)

STECIAL PROGRAM Outer Ring, Near 5 Mile Radius, Indicator Locations 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Date Placed:

01-01-87 03-27-87 06-27-87 10-03-87 Date Removed:

03-27-87 06-27-87 10-03-87 12-30-87 Days in the Field:

85 92 98 88 Location Average mR/Qtr 0-201-1 11.6i0.6 17.610.7 13.2il.0 15.7i0.P Q-201-2 13.610.8 15.810.5 13.910.8 14.910.4 Q-202-1 10.210.5 15.510.6 11.510.8 13.8i0.5 Q-202-2 10.910.2 13.310.4 11.110.9 12.SiO.4 l

Q-203-1 10.710.5 16.110.6 12.410.7 14.110.6 l

Q-203-2 14.710.3 17.310.7 16.210.7 15.910.4 l

Q-204-1 13.810.6 18.410.6 15.710.9 16.210.8 Q-204-2 14.310.3 17.610.8 15.4tl.0 16.810.4 l

Q-205-1 13.010.4 17.310.5 16.011.4 15.610.9 Q-205-2 11.610.4 15.211.0 12.110.6 14.210.6 Q-206-1 11.910.5 14.910.8 13.9tl.4 13.510.5 Q-206-2 12.510.7 14.710.7 13.010.7 13.810.6 Q-207-1 12.810.3 17.411.0 14.511.1 16.110.4 Q-207-2 10.810.8 13.710.5 11.7i0.9 Missing 0-208-1 11.610.3 16.2t0.6 13.0*1.0 14.810.6 Q-208-2 12.010.4 16.910.4 13.410.8 16.8tl.4 Q-209-1 12.210.4 18.6i0.6 12.310.7 14.910.6 Q-209-2 10.010.8 15.410.9 10.610.9 14.010.5 Q-210-1 11.210.5 14.310.6 12.411.5 12.710.5 Q-210-2 13.510.8 17.210.4 15.611.1 15.610.5 Q-211-1 14.310.9 19.110.9 15.110.7 17.511.1 Q-212-1 13.910.7 16.311.5 16.211.2 15.0i0.6 Q-212-2 9.310.7 14.110.6 11.2tl.3 13.710.6 Q-213-1 11.910.4 14.310.7 13.911.3 12.310.5 Q-213-2 9.310.5 13.610.6 10.011.2 13.311.2 Q-214-1 13.310.2 15.010.9 15.511.0 14.810.7 Q-214-2 13.110.4 16.210.6 14.710.8 15.410.6 Q-215-1 13.310.4 17.810.5 14.7t0.9 16.211.2 Q-215-2 14.210.8 18.210.7 15.210.9 16.7tl.0 Q-216-1 13.010.6 16.210.4 13.410.7 16.211.2 Q-216-2 14.610.6 16.511.0 15.111.0 16.610.8 Mean i s.d.

12.411.5 16.211.6 13.6tl.8 15.011.4

_ _ _ _ _ _ _ _ _ __ _ _ _ _ __ _ __ _ _ A 3.

~

o APPENDIX II METEOROLOGICAL DATA 84 i

v 6.

QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - JANUARY-MARCH 1987 STABILITY CLASS - EXTREMELY UNSTABLE (DIFF TEMP 296-33 FT)

WINDS MEA 3URED AT 296 FEET WIND WIND SPEED (IN MPH)

DIRECTION

.8-3 4-7 8-12 13-18 19-24 OT 24

. TOTAL

{

N O

O O

O O

O O

NNE O

O O

O O

O O

NE O

O O

O O

O O

-ENE O

O O

O O

O O

E O

O O

O O

n 0

ESE O

O O

O O

O O

i SE O

O O

O O

O O

SSE O

O O

O O

O G

S 0

0 0

-0 0

0 C

SSW 0

0 0

0 0

0 0

i SW O

O O

O O

O O

i WSW 0

0 0

0 0

0 0

W O

O O

O O

O O

j WNW O

O O

O O

O O

i NW 0

0 0

0 0

0 0

NNW 0

0 0

0 0

0 0

i i

VARIABLE O

O v

0 0

0 O

i I

TOTAL 0

0 0

0 0

0 0

l Hours of calm in this stability classt 0

Hours of missing wind measurements in this stability classt 0

Hours of missing stability measurements in all stability classest 25 1

I 85

u

-QUAD CITIES NUCLEAR POWER STATION PERIOD.OF RECORO - JANUARY-MARCH 1987 STABILITY CLASS - MODERATELY UNSTABLE (DIFF' TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN MPH)

DIRECTION

.8-3 4-7 8-12 13-18 19-24 OT 24 TOTAL N

O O

O O

O O

O NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

1 1

ESE O

O O

O O

O O

SE O

O O

O O

O O

B SSE O

O O

O 1

0 1

S O

O O

O 1

0 1

SSW O

O O

O O

O O

SW O

O O

O O

O O

WSW O

O 1

2 O

O 3

W 0-0 0

1 1

0 2

WNW O

O O

1 O

O 1

NW O

O O

2 i

O 3

NNW O

O O

O O

O O

VARIsBLE O

O O

O O

O O

i TOTAL 0

0 1

6 4

1 12 Hours of calm in this stability class:

O Hours of mi: ding uand measurements in this stability classt O

Hours of missing stability measurements in all stability classes 25 86 l

OUAD CITIES NUCLEAR POWER STATION j

PERIOD OF RECORD - JANUARY-MARCH 1987 STABILITY CLASS - SLIGHTLY UNSTABLE (DIFF TEMP 296-33 FT) f WINDS MEASURED AT 296 FEET 4

WIND WIND SPEED (IN MPH) i DIRECTION

.8-3 4-7 6-12 13-18 19-24 GT 24 TOTAL g

N O

O O

Q 0

0 0

i NNE O

O O

O 1

1 2

l

~

NE 0

0 0

0 1

0 1

ENE O

O 1

1 0

0 2

E o

0 0

0 0

7

-7 ESE O

O O

O 2

2 4

I i

SE O

O O

1 3

0 4

SSE O

O O

1 0

0 1

S O

O 1

1 2

0 4

SSW 0

0 0

4 1

0 5

t l

SW O

O O

3 i

O 4

WSW O

O 1

4 4

0 9

i W

0 0

0 4

0 0

4 i

WNW 0

0 1

1 1

0 3

i i

l NW 0

0 1

1 1

0 3

NNW 0

0 0

0 0

0 0

l VARIADLE O

O O

O O

O O

TOTAL 0

0 5

21 17 10 53

[

f Hours of calm in this stability class:

O i

Hours of missing wind measuren.ents in this stability classt 0

l Hours of missing stability measurements in all stability classest 25 I

l I

i 87

r QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - JANUARY-MARCH 1987 STABILITY CLASS - NEUTRAL (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET

-WIND WIND SPEED (IN MPH)

DIRECTION

.8-3 4-7 8-12 13-18 19-24 OT 24 TOTAL N

1 9

9 11 0

0 30 i

NNE 3

5 7

9 4

17 45

.NE 1

9 18 18 44 15 105 ENE 1

5 18 37 40 27 128 e

E 2

7 20 33 17 26 105 i

ESE 2

13 8

15 12 2

52 SE 2

14 3

3 1

0 23 l

SSE 3

3 2

7 0

0 15 S

5 7

7 6

6 0

31 SSW 4

13 24 11 9

0 61 SW 2

11 16 11 4

0 44 WSW 3

9 15 27 7

2 63 W

2 7

23 37 21 0

90 WNW 3

8 32 59 24 25 151 NW 1

19 16 59 19 7

121 NNW 2

13 10 21 8

11 65 VARIABLE O

O O

O O

O O

I TOTAL 37 152 228 364 216 132 1129 l

r Hours of calm in this stability classt 0

[

4 Hours of missing wind measurements in this stability class:

4.

Hours of missing stability measurements in all stability classest 25 i

e 8

85 t

u-

'a n

QUAD CITIES NUCLEAR POWER-STATION 1

PERIOD OF RECORD - JANUARY-MARCH 1987 i

STABILITY CLASS - SLIGHTLY STABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN MPH)

DIRECTION

.8-3 4-7 8-12 13-18 19-24 GT 24 TOTAL I

N O

8 2

7 0

0 17 NNE 1

4 11 7

1

-0 24 NE 5

4 8

20 0

0 37 ENE 2

7 9

30 17 1

66 E

4 12 12 17

.13 25 83 ESE O

5 5

6 10 3

29 i

SE 2

1 4

8 7

0 22 SSE 2

5 3

11 3

0 24 S

O 2

7 13 8

2 32 r

SSW 1

9 16 12 4

1 43 f

SW 1

6 12 15 2

0 36 i

WSW 2

1 10 15 1

2 31 I

W i

5 11 16 8

2 43 WNW 3

0 10 19 5

1 38 NW i

2 11 7

4 0

25 i

NNW 2

2 9

3 0

0 16 VARIABLE 0

0 0

0 0

0 0

i TOTAL 27 73 140 206 83 37 566 I

i Hours of calm in this stability class:

0 Hours of missing wind measurements in this stability classt 12 f

Hours of missing stability measurements in all stability classes 25 l

89 I

--_y-y o

5 L

QUAD CITIES NUCLEAR POWER STATION f

PERIOD OF RECORD JANUARY-MARCH

'1987 L

STABILITY CLASS

. MO?)ERATELY STABLE (DIFF TEMP 296-33 FT) i WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN MPH)

DIRECTION

.8-3 4-7 8-12 13-18 19-24 GT 24 TOTAL N

O 2

2 O

O O

4 l

l NNE O

O 2

2 O

O 4

l NE 2

1 1

3 0

0 7

ENE-1 0

5 1

1 0

8 J

E O

4 14 22 8

4 52 ESE O

3 10 10 7

0 30 SE 1

J 2

3 0

0 9

SSE 1

1 0

7 0

0 9

l I

S 1

2 3

4 2

0 12

(

r s

~

SSW 2

2 7

5 0

0 16 SW O

7 6

2 O

O 15 l

r d,

j WSW O

3 2

5 0

0 10 i

1 W

O 2

2 8

4 0

16

(

l Wl;W O

2 0

5 0

0 7

I i

NW O

2 4

3 0

0 9

l NNW O

2 O

O O

O 2

VARIABLE O

O O

O O

O O

i TOTAL 8

36 60 80 22 4

210 l

I Hours of calm in this stability class O

Hours of missing wind measurements in this stability class:

O l

l Hours of missing stability measurements in all stab.511ty classest 25 4

i i

90

QUAD CITIES NUCLEAR POWER STATION FERIOD OF RECORD - JANUARY-MARCH

-1987 STABILITY CLASS - EXTREMELY STABLE (DIFF TEMP 296-33 FT)

'i WINDS MEASURED AT 296 FEET WIND WIND SPEED.(IN MPH)

DIRECTION

.8-3 4-7 G 13-18 19-24 OT 24 TOTAL N

0 0

0' O

O O

O NNE O

O O

O O

O O

[

NE O

1 0

0 0

0 i

s I

ENE 1

2 0

0 0

0 3

E O

1 7

1 0

0 9

l 1

ESE O

2 3

5 3

0 13 SE O

2 6

2 0

0 10 i

SSE O

2 0

S O

O 10 5

S O

4 1

4 3

0 12 f

SSW 3

5 9

3 3

0 23 t

l SW 0

0 4

7 0

0 11 I

WSW 1

0 0

6 0

0 7

W D

0 0

4 0

0 4

WNW 0

1 2

2 0

0 5

NW 0

1 2

0 0

0 3

i NNW 0

0 0

0 0

0 0

i VARI ABL E O

O O

O o

0 o'

TOTAL 5

21 34 42 9

0 111 I

Hours of calm in this stability class 0

[

Hours of missing wind measurements in this stability classt 0

Hours of missing stability measur ement s in all stability classest 25 j

i 91 l

l P

_...__,3

y i-L QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - APRIL-JUNE 1987 STABILITY CLASS - EXTREMELY UNSTABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT-296 FEET l

WIND WIND SPEED (IN MPH) l DIRE ^, TION

.8-3 4-7 8-12 13-18 19-24 OT 24 TOTAL l

l N

0 0

0 0

0 0

0 NNE-0 0

0 0

0 0

0 NE O

O O

O O

O O

I ENE O

O O

O O

O O

E O

O O

O O

O O

i ESE O

O' O

O O

O 0

SE o

0 0

0 0

0 0

SSE O

O O

O 6

1 7

S 0

0 1

0 0

0 1

l l

SSW 0

0 0

4 0

0 4

l SW 0

0 0

0 0

0 0

l l

WSW 0

0 0

0 0

0 0

W 0

0 1

0 0

0 i

WNW 0

0 2

0 0

0 2

i NW 0

0 0

0 0

0 0

l l

NNW 0

0 0

0 0

0 0

l VARIABLE O

O O

O O

O O

l l

l TOTAL 0

0 4

4 6

1 15 Hours of calm in this stability classt 0

l Hours of missing wind measurements in this stability classt O

Hours of missing stability measurements in all stability classest 0

l l

92 l

I

"a ;

l v

-QUAD CI~IES NUCLEAR PO$ER STATION PERIOD OF RECORD.- APRIL-JUNE 1987 STABILITY CLASS - MODERATELY UNSTABLE (DIFF TEMP 296-33 FT) l WINDS MEASURED AT '296 FEET l

WIND WIND SPEED (IN MPH) i DIRECTION

.8-3 4-7 8-12 13-18 19-24 OT 24 TOTAL N

0 O

O O

O O

O I

NNE O

O O

O O

1 1

L NE O

o 0

0 0

0 0

.ENE O

O O

O 3

0 3

l E

.0 0

0 0

0 0

0 l

1 ESE O

O O

O O

O O

SE O

O O

5 1

0 6

l i

SSE O

O 2

0 1

0 3

t S

O O

3 3

0 0

6 l

i SSW 0

0 8

5 0

0 13 SW G

1 3

6 0

0 10 i

~

WSW O

O 5

0 0

0 5

W 0

0 3

6 0

0 9

l WNW 0

0 8

0 0

0 0

l NW 0

0 0

1 2

0 3

NNW 0

0 0

0 0

0 0

VARIABLE O

O O

O O

O O

TOTAL 0

1 32 26 7

1 67 I

l i

Hours of calm in this stability class:

0

[

Hours of

.issing wind measurements in this stability class:

O' Hours of missing stability measurement s i n all stability classest 0

I t

93

[

,mww

---e

.-gw v.

r -,

,-r.---e,--m pw-r- % y,q,,.-mw,,,.mem.m.r,M~,e-

-+-v-

  • - - - = ~

QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - APRIL-JUNE 1987 STABILITY CLASS - SLIGHTLY UNSTABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN MPH) i DIRECTION

.8-3 4-7 8-12 13-18 19-24 GT 24 TOTAL N

0-0 0

0 2

0 2

NNE O

O O

O 1

1 2

NE o

0 0

0 0

0 0

ENE O

O O

1 3

0 4-E O

O O

C 1

0 1

ESE O

O O

O O

O O

SE o

0 0

1 1

0 2

SSE O

O 6

0 2

0 8

S 0

0 8

5 3

1 17 SSW 0

3 10 8

2 0

23 SW 0

0 4

5 1

0

-10 WSW 0

0 2

2 1

0 5

W 0

2 3

6 0

0 11 WNW 0

1 10 5

2 0

18 NW 0

0 3

1 3

1 S

NNW O

O O

2 1

0 3

VARIABLE O

O O

O O

O O

f TOTAL 0

6 46 36 23 3

114 Hours of calm in this stability classt 0

Hours of missing wind measurements in this stability class:

3 j

Hours of missing stability measurements in all stability classest 0

l t

F i

94 i

e t

QUAD CITIES NUCLEAR' POWER STATION PERIOD OF RECORD - APRIL-JUNE 1987 STABILITY CLASS - NEUTRAL (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET

[

WIND WIND SPEED (IN MPH) t DIRECTION

.8-3 4-7 8-12 13-18 19-24 GT 24

. TOTAL N

O 4

26 14 5

0 49 NNE O.

5 14 14 2

3 38 i

NE o

14 13 14 17 5

63 ENE O

16 41 34 19 6

116 E

O 13 27 20 7

0 67 ESE O

11 9

13 3

0 36 SE O

8 21 13 3

0 45 SSE O

3 6

6 3

1 19 S

3 5

15 6

7 0

36 SSW O

18 23 28 8

0 77 SW 0

15 11 18 7

0 51 WSW O

7 6

11 4

0 28 W

0 10 6

14 8

2 40 WNW 2

12 15 34 16 3

82 NW 1

10 18 29 9

5 72 r

NNW O

6 21 24 7

1 59 i

I VARIABLE O

O O

O O

O O

[

i l

TOTAL 6

157 272 292 125 26 878 l

i i

Hours of calm in this stability classt 0

Hours of missing wind measurements in this stability classt 12 Hours of missing stability measurement s in all stability classest C

i i

95 i

e i

g-i QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD

. APRIL-JUNE

.1987 STABILITY CLASS - SLIGHTLY STABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET.

WIND WIND SPEED (IN MPH)

DIRECTION

.8-3 4-7 8-12 13-18 19-24 GT 24 TOTAL f

F N

0 3

7 17 2

0 29 i

NNE O

4 6

16 6

0 32 NE o

3 7

25 6

1 42 ENE O

3 12 23 13 0

51 E

O 4

9 19 15 1

48 j

ESE O

'5 14 14 5

0 38 t

SE O

5-13 8

6 0

32 SSE O

2 8

15 1

1 27 S

0 1

8 16 2

0 27

$$W G

3 33 43 8

0 87 i

SW 2

2 40 33 5

0 82 WSW O

4 16 22 4

3 49 I

W 0

4 1

6 3

0 14 i

WNW O

4 6

25 4

0 39 l

4 NW 0

4 10 14 10 0

38 i

NNW 0

8 12 7

2 0

29 f

VARIABLE O

O O

O O

O O

l TOTAL 2

59 202 303 92 6

J. 64 b

Hours of calm in this stability class O

Hours of missing wind measurements in this stability class:

19 Hours of missing stability measurement s in all stability classest 0

i t

t 96

[

1 i

. _., _ _ ~.. _ _ _ _ _ _.. _ _ _. _ _ _. _ _ _ _ _ _ _ _. _.. _ _. _. _ _ _. -. - _. _. _ _ _ _ _ _......... _..,. _ ___

QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - APRIL-JUNE 1987 g

STABILITY CLASS - MODERATELY STABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN MPH)

DIRECTION

.8-3 4

.7 8-12 13-18 19-24 OT 24 TOTAL N

O 2

6 3

1 0

12 NNE O

2 6

4 0

0 12 NE O

2 8

1 0

0 11 ENE O

1 3

8 0

0 12 E

o 3

7 22 1

0 33 4

ESE O

4 6

27 7

0 44 SE O

1 11 17 4

0 33 SSE 1

0 3

6 2

0 12 S

0 0

6 26 3

0 35 SSW 0

5 9

22 0

0 36 SW 0

2 to 5

1 0

18 WSW 0

2 4

2 0

0 W

0 1

1 2

1 0

5 WNW 0

1 1

4 0

0 6

NW 0

1 2

4 3

0 10 NNW 0

1 0

4 6

0 11 VARIABLE O

O O

O O

O O

TOTAL 1

28 83 157 29 0

298 Hours of calm in this stability class:

0 Hours of missing wind measurements in this stability classt 1

Hours of missing stability measurements in all stability classest 0

97

o e

QUAD CITIES NUCLEAR FOWER STATION PERIOD OF RECORD - APRIL-JUNE 1987 STABILITY CLASS - EXTREMELY STABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED'(IN MPH)

' DIRECTION

.8-3 4-7 8-12 13-18 19-24 OT 24 TOTAL N

O 1

1 2

0 0

4 NNE O

4 2

6 0

0 12 NE O

1 2

0 0

0 3

ENE O

3 1

0 0

0 4

E O

O 1

4 0

0 5

ESE o

0 3

4 0

0 7

SE O

3 6

6 1

0 16 SSE O

1 5

4 2

0 12 S

0 0

7 4

3 0

14 SSW 0

3 3

6 1

0 13 SW 0

3 1

0 0

0 4

WSW 0

0 0

0 0

0 0

W 0

2 1

0 0

0 3

WNW 0

1 2

0 0

0 3

NW 0

1 1

0 1

0 3

NNW O

1 0

0 2

0 3

VARIABLE O

O O

O O

O O

TOTAL 0

24 36 36 10 0

106 l

i Hours of calm in this stability class 0

Hours of missing wind measurements in this stability classt 7

Hours of missing stability measur ement s in all stability classest 0

l l

]

98 i

.g_________-_____-___.

- l-QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - JULY-SEPTEMBER 1987 STABILITY CLASS - EXTREMELY UNSTABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN MPH) 4 DIRECTION

.8-3 4-7 S-12 13-18 19-24 GT 24 TOTAL N

O O

O 1

O O

1 1

I NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

O O

O O

O O

i E

O O

O O

O O

O 3

ESE O

O O

O O

O O

i SE O

1 4

2 O

O 7

SSE O-0 4

0 0

0 4

i S

O 1

2 9

0 0

12 SSW O

O 15 20 0

0 35 SW O

1 10 2

O O

13 WSW O

O 2

2 i

O 5

l 4

W O

O 5

10 0

0 15 f

WNW O

1 3

4 0

0 8

i NW O

1 7

6 2

0 16 NNW O

1 0

3 0

0 4

VARIABLE O

O O

O O

O O

r i

TOTAL 0

6 52 59 3

0 120 i

Hours of calm 2n this stability class:

O i

Hours of missing wind measurements in this stability classa O

Hours of missing stability measurements in all stability classest 37 i

l I

i l

l r

99 a

--me

y QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - JULY-SEPTEMBER 1987 STABILITY CLASS - MODERATELY UNSTABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN MPH)

DIRECTION

.8-3 4-7 8-12 13-18 19-24 GT 24 TOTAL

[

N O

O 1

1 1

0 3

NNE O

O 6

3 O

9 NE O

O 1

O O

O.

1 l

ENE O

O O

O O

O O

l E

O O

O O

O O

O ESE O

1 O

O O

O 1

SE O

2 4

1 O

O 7

SSE O

2 3

3 0

0 8

i l

S O

O 5

9 1

0 15 i

SSW O

2 11' 5

0 0

18 j

SW O

5 2

i O.

O 8

l WSW O

3 3

3 0

0 9

[

W O

1 1

2 1

O E

WNW O

2 6

8 2

0 18 f

i NW O

3 2

1 O

O 6

f NNW O

O 4

3 1

0 8

l VARIABLE O

O O

O O

O O

TOTAL 0

21 49 40 6

0 116 l

l Hours of calm in this stability class:

O j

Hours of missing wind measurements i n this stability classt O

Hours of missing stability measurements in all stability classest 37 d

100 t

t

,,n-,

a

.,,.,,..-.,c--

,,,,,-,,,,------,.,,,....-,,---,.n--,

[

l' OUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - JULY-SEPTEMBER 1987 STABILITY CLASS - SLIGHTLY UNSTABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN MPH)

DIRECTION

.8-3 4-7 8-12 13-18 19-24 OT 24 TOTAL E

l N

O 1

0 1

O O

2

[

NNE O

O 5

1 O

O 6

NE O

1 1

O O

O 2

ENE O

1 O

O O

O 1

E O

2 O

O O

O 2

ESE O

1 0

1 O

O 2

SE O

O 5

4 0

0 9

SSE O

1 9

i O

O 11 S

O 2

6 4

2 1

15 SSW O

9 9

9 0

0 27 i

i SW O

2 6

1 O

O 9

k j

WSW O

2 1

1 O

O 4

L W

O 3

6 5

0 0

14 I

WNW O

4 18 9

1 0

32 i

l i

NW O

1 6

1 2

0 10 NNW O

1 4

1 1

0 7

i i

VARIABLE O

O O

O O

O O

I r

TOTAL 0

31 76 39 6

1 153 1

1 l

Hours of calm in this stability classt O

r i

Hours of missing wind measurements in this stability class O

l Hours of missing stability measurements in all stability classest 37 1

1 i

1 i

[

i I

h 101 I

u QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - JULY-SEPTEMBER 1987 STABILITY CLASS - NEUTRAL (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN MPH)

DIRECTION

.8-3 4-7 8-12 13-18 19-24 OT 24 TOTAL N

O 6

29 10 0

0 45 NNE O

6 16 5

0 0

27 NE O

10 5

0 1

0 16 ENE O

2 10 1

1 1

15 E

O 4

11 12 0

0 27 ESE O

14 19 23 4

0 60 SE O

9 31 7

2 0

49 SSE O

16 9

8 0

0 33 S

O 7

10 23 0

1 49 SSW 0

18 27 19 1

0 65 SW 0

23 26 5

0 0

54 WSW G

9 13 11 0

0 33 W

O 9

9 18 4

0 40 WNW 0

14 16 33 8

0 71 NW 0

8 22 27 0

0 57 NNW 0

8 25 15 2

0 50 VARIABLE O

O O

O O

O O

TOTAL 0

163 278 217 31 2

691 Hours of calm in this stability classt 0

Hours of missing wind measurements in this stability classt 0

Hours of missing stability measurements an all stability classest 37 102

i i

?

QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - JULY-SEPTEMBER 1987 STABILITY CLASS - SLIGHTLY STABLE (D5FF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN MPH) f DIRECTION

.8-3 4-7 8-12 13-18 19-24 GT 24 TOTAL

~

j N

1 5

10 8

0 0

24 NNE O

5 4

-3 1

0 13 i

NE O

1 4

4 1

0 10 i

ENE o

2 13 9

0 0

24 E

O 4

13 24 2

0 43 ESE O

5 14 20 2

0 41 SE o

2 13 5

0 0

20 SSE o

6 26 16 0

0 48 S

O 5

23 38 9

1 76 t

SSW 0

7 32 49 8

0 96 i

SW 0

11 28 16 3

0 58 l

WSW 1

9 23 14 1

0 48 W

0 3

11 25 2

0 41 WNW 0

5 9

22 0

0 36 i

NW 0

4 14 32 2

0 52 i

NNW 0

7 20 12 0

0 39 l

1 VARIABLE O

O O

O O

O O

l 1<

~

l TOTAL 2

81 257 297 31 1

669 l

I 4

i Hours of calm in this stability classt 0

l Hours of missing wind measurements in this stability classt 0

{

j Hours of massing stability measurements in all stability classest 37 l

i I

t l

i l

l 103 1

l sv Q wm7 v'-vyn,-yv-y-vs'

=q we-m%-w+v -.

-. --c

_ g __

r i

I QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - JULY-SEPTEMBER 1987 i

STABILITY CLASS - MODERATELY STABLE (DIFF TEMP 294-33 FT)

I l

WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN NPH)

DIRECTION

.8-3 4-7 8-12 13-18 19-24 GT 24 TOTAL ~

l N

0 1

0 0

0 0

1-NNE 1

0 13 3

0 0

17 NE O

6 6

3 O

O 15 ENE o

4 3

1 0

0 8

l E

O 1

6 3

0 0

10 l

[

ESE O

5 5

16 2

0 28

{

SE O

3 16 11 1

0 31 9

SSE O

3 12 6

0 0

21 l

I.

S 0

9 5

12 7

1 34

[

t SSW O

5 11 27 1

0 44 l

l SW 1

10 6

1 1

0 19 WSW 0

4 8

O

'16 W

0 1

5 1

0 0

7 WNW 0

3 7

to 2

0 22 NW 0

0 5

8 4

0 17 J

NNW 0

3 3

5 0

0 11 4

l VARIABLE O

O O

O O

O O

TOTAL 2

58 111 109 20 1

301 I

l i

Hours.of calm in this stability class O

Hours of missing wind measurements in this stability classt 0

j

{

Hours of missing stability measurements in all stability classes 37 l

l l

104 i

I f

OVAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - JULY-SEPTEMBER 1987

[

STABILITY CLASS - EXTREMELY STABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET

-[

?

]

WIND WIND SPEED (IN MPH)

DIRECTION

.S-3 4-7 S-12 13-18 19-24 GT 24 TOTAL l

r N

0 1

1 1

0 0

3 l

NNE O

O O

O O

O O

i i

NE O

O 1

0 0

0 1

j 1

ENE O

2 5

0 0

0 7

~

t E

O 2

7 0

0 0

9 l

ESE O

2 46 7

1 0

16 i

r SE O

1 6

8 0

0 15 l

4 i-j SSE O

3 9

9 0

0 21 S

0 0

6 15 2

0 23 4

SSW 0

0 2

3 1

0 6

SW 0

2 4

0 0

0 6

4 WSW 0

1 1

0 0

0 2

l W

0 3

1 0

0 0

4 5

WNW 0

3 0

2 0

0 5

JW 0

0 2

0 0

0 2

NNW 0

1 0

0 0

0 1

VARIABLE o

0 0

0 0

0 0

f 4

I TOTAL 0

21 51 45 4

0 121 L

i

(

Hours of calm in this stability classt 0

Hours of missing wind measurements in this stability classt 0

f Hours or missing stability measurements in all stability classest 37 i

105 l

4 i

I

.-. -,,. _... - _.. _ ~ _. -

_,-._m.,

.y QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - OCTOBER-DECEMBER 1987 STABILITY CLASS - EXTREMELY UNSTABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN MPH)

DIRECTION

.8-3 4-7 8-12 13-18 19-24 GT 24 TOTAL N

O O

O O

O O

O NNE O

O O

O O

O O

NE O

O O

O O

O O

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

O O

O O

f SE O

O O

O O

O O

SSE O

O 1

3 1

0 5

S O

O O

5 1

0 6

SSW 0

0 3

2 7

3 15 SW 0

0 1

0 0

0 1

+

WSW 0

0 0

0 0

0 0

W 0

1 0

0 0

1 2

WNW 0

0 2

0 1

1 4

l NW O

O O

2 0

0 2

l NNW O

O O

O O

O O

i VARIABLE O

O O

O O

O O

4 l

TOTAL 0

1 7

12 10 5

35 Hours of calm in this stability class O

Hours of missing wind measurements in this stability class O

Hourn'of missing stability measurements in all stability classes 35 106

QUAD CITIES NUCLEAR POWER STATION l

PERIOD OF RECORD - OCTOBER-DECEMBER 1987 STABILITY CLASS - MODERATELY UNSTABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN MPH)

DIRECTION

.8-3 4-7 8-12 13-18 19-24 GT 24 TOTAL N

0 O

O O

O O

O 1

O O

O O

O O

O NNE c

I NE O

O O

O O

O O

i f

f ENE O

O O

O O

O O

f I

E O

O O

0 0

0 0

ESE O

O O

O O

O O

SE O

O O

1 0

0 1

i SSE o

0 0

1 0

0 1

0 0

3 4

0 0

7 i

SSW 0

0 0

3 0

1 4

$W 0

0 2

0 0

0 2

WSW 0

0 1

1 0

0 2

i

.l W

0 3

3 2

0 0

8 1

WNW 0

1 2

6 5

0 14 i

i NW 0

1 1

3 2

0 7

i NNW 0

0 0

0 1

3 4

7 1

VARIABLE O

O O

O O

O O

i 1

TOTAL 0

5 12 21 8

4 50 l

I e

i Hours of calm in this stability classt 0

Hours of missing wind measurements in this stability classt 0

j Hoers of missing stability measurements in all stability classes 35 i

i i

i 107 l

i

,.w-,,.n-,---,,..-e,-w,,,,

nn, nn-


n~.---m-,,.e

-,,um

,.,.,-_---,-n-

_ -- g_-

o QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - OCTOBER-DECEMBER 1987 STABILITY CLASS - SLIGHTLY UNSTABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN NPH)

DIRECTION

-.8-3 4-7 8-12 13-18 19-24 GT 24 TOTAL N

O O

O O

O O

O NNE o

0 0

0 0

0 0

NE o

0 0

0 0

0 0

ENE O

O O

O O

O O

E O

O O

O O

O O

ESE O

O O

O O

O O

SE O

O O

O O

O O

SSE O

O 1

2 1

0 4

S 0

1 3

1 0

0 5

SSW 0

2 2

4 2

0 to SW 0

1 6

0 1

0 G

WSW 0

1 1

3 1

0 6

W 0

2 5

9 3

1 20 WNW 0

0 4

5 4

1 14 NW 0

1 1

4 4

0 10 NNW 0

1 1

0 2

3 7

VARIABLE 0

0 0

0 0

0 0

TOTAL 0

9 24 20 18 5

84 Hours of calm in this stability classt 0

Hours of missing wind measurements in this stability classt 0

Hours of missing stability measurements in all stability classest 35 e

108

o QUAD CITIES NUCLEAR POWER STATION PERICD OF RECORD - OCTOBER-DECEMBER 1987 STABILITY CLASS - NEUTRAL (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED (!N MPH)

DIRECTION

.8-3 4-7 8-12 13-18 19-24 GT 24 TOTAL N

1 8

23 10 3

1 46 NNE o

10 13 18 7

3 51 NE 2

1 3

18 10 1

35 ENE O

5 6

33 14 0

58 E

O 5

9 17 1

0 32 ESE O

17 10 19 12 0

58 SE O

2 5

18 1

0-26 SSE O

1 9

18 9

0 37 S

O 1

8 20 15 6

50 SSW 0

3 12 26 9

5 55 SW 1

3 15 9

4 0

32 WSW 1

4 13 14 20 3

55 W

0 6

19 30 23 21 99 WNW 1

4 13 79 74 21 192 NW 0

0 16 68 34 8

134 NNW 0

4 19 32 7

0 62 VARIABLE O

O O

O O

O O

TOTAL 6

82 193 429 243 69 1022 Hours of calm in this statiility classt 0

Hours of missing wind measurements in this stat.111ty class 29 Hours of missing statoility measurements in all stat 111ty classes 35 109

r u

i

)

l f

l OUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - OCTOBER-DECEMBER 1987

-STABILITY CLASS - SLIGHTLY STABLE (DIFF TEMP 296-33 FT)

(

. WINDS MEASURED AT 296 FEET i

WIND WIND SPEED (IN MPH) i DIRECTION

.0-3 4-7 8-12 13-18 19-24 OT 24-

' TOTAL

{

N O

2 14 15 1

0 32 NNE 1

1 8

2 O

O 12 NE 1

5 3

2 G

O 11 ENE 1

3 5

4 2

0 10 i

E 1

2 6

12 5

3 29 ESE O

2 12 11 2

2 29 SE O

O 15 28 3

3 49 SSE 1

J 12 26 14 5

61 S

O 4

16 30 19 3

72 l

SSW 1

3 25 34 17 0

80 SW O

1 23 37 7

0 68 WSW O

2 10 15 11 1

39 W

O O

7 12 4

1 26 l

i WNW O

1 16 29 15 1

62 i

i NW 1

3 14 15 4

1 38 NNW O

5 13 9

0 0

27 i

VARIABLE O

O O

O O

O O

l l

t TOTAL 7

37 199 281 106 20 650 Hours of calm in this stab 111ty classt O

[

Hours of missing wind measurements in this stability classt 15 i

Hours of missing stability measurements in all stability classest 35 110

O QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - OCTOBER-DECEMBER 1987 STABILITY CLASS - MODERATELY STABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND WIND SPEED (IN NPH)

DIRECTION

.S-3 4-7 S-12 13-19 19-24 GT 24 TOTAL N

0 2

8 5

0 0

15 NNE o

2 3

'l 0

0 6

NE O

1 1

6 0

0 8

ENE O

1 3

3 0

0 7

E 1

1 5

2 0

0 9

ESE O

2 6

2 0

0 10 SE O

3 13 1

0 20 13 3

0 21 SSE O

O S

0 0

0 23 11 0

42 SSW 0

0 19 16 1

0 36 SW 0

3 7

4 0

0 14 WSW 1

0 2

2 0

0 5

W 0

0 2

1 0

0 3

WNW O

2 0

1 3

0 6

NW 0

2 3

2 0

0 7

NNW 0

2 6

3 0

0 11 VARIABLE O

O O

O O

O O

TOTAL 2

21 S1 97 19 0

220 Hours of calm in this stability classt 0

Hours of missing wind measurements in this stability class:

1 Hours of massing stability measurements in all stability classest 35 111

m

  • i l

QUAD CITIES NUCLEAR POWER STATION PERIOD OF RECORD - OCTOBER-DECEMBER 1987 STABILITY CLASS - EXTREMELY STABLE (DIFF TEMP 296-33 FT)

WINDS MEASURED AT 296 FEET WIND.

WIND SPEED (IN MPH)

DIRECTION

.8-3.

4-7 8-12 13-18 19-24 GT 24 TOTAL N

O 1

0 0

0

'O 1

NNE O

O 1

0 0

0 1

NE O

2 3

1 O

O 6

ENE O

O O

1 0

0 t

E O

O 2

3 0

0 5

ESE O

2 O

O O

O 2

SE O

5 0

3 2

0 10 SSE O

O 1

7 1

0 9

S O

O 1

7 0

9 8

SSW 0

3 15 3

0 0

21' SW O

O 2

O O

O 2

WSW 0

0 0

0 0

0 0

W O

O O

O O

O O

WNW O

O O

O O

O O

NW 0

0 0

0 0

0 0

NNW O

O 1

0 0

0 1

VARIABLE O

O O

O O

O O

TOTAL 0

13 26 25 3

0 67 Hours of calm in this stability class:

0 Hours of missing wind measurements in this stability classt O

Hours or missing stability measurements in all stability classes 35 I

l l

112

-w-0 APPENDIX III LISTING 0F MISSED SAMPLES 113

n..

9 6

APPENDIX III l

LISTING OF MISSED SAMPLES b

Expec ted f

Collection Scmple Type Location Date Reason i

AP, AI Q Q-05 07-25-87 Sample lost in shipment.

AP, Al Q-06 07-24-87 Sample lost in shipment.

AP, Al Q Q-16 07-25-87 Sample lost in shipment.

Milk Q Q-18 07-25-87 Sample lost in shipment.

Public Water Q Q-20 07-25-87 Sample lost in shipment.

Cooling Water Q Q-22 07-25-87 Sample lost in shipment.

TLD Q-116-1 4th Qtr.

TLDs lost.

TLD Q-207-2 4th Qtr.

TLDs lost.

l l

r 1

114

P M/

RLB-88-36 January 25, 1988 Mr. A. Bert Davis Regional Administrator Directorate of Inspection and Enforcement Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137

Subject:

Quad Cities Nuclear Power Station Operating Report, NRC Dockets 50-254 and 50-265.

Dear Mr. Davis:

Enclosed is Part 3 of the Quad Cities Nuclear Power Station Operating Report, reporting results of Environmental Radiological and Meteorological monitoring.

Part 1, facility operating experience was submitted under separate cover in February, and Part 2, radioactive effluents in February and August.

Two copies of the report are provided for your use. One copy each will be forwarded to Document Control and the NRC Resident Inspector.

Sincerely yours, h-A 0%h R. L. Bax Station Manager Quad Cities Station Enclosure RLB/BE/kmb

./

49

\\