ML20151W297

From kanterella
Jump to navigation Jump to search
Rev 01 to Field Quality Procedure FQP-03, Procedure for Qualification & Certification of NDE Personnel in Accordance W/Asnt SNT-Tc-1A & Section XI
ML20151W297
Person / Time
Site: Limerick 
Issue date: 10/13/1987
From: Brown G, Larrew J
GENERAL ELECTRIC CO.
To:
Shared Package
ML20151W267 List:
References
FQP-03, FQP-3, NUDOCS 8808240029
Download: ML20151W297 (20)


Text

_ _ _ _ _ _ _ _. _ _

(~.'\\

l O

wuctria e'*"t scaviCos oceratuent rea-oa Field Quality Procedure Revision 01 j

FIELD QUALITY PROCEDURE FQP-03 PROCEDURE FOR QUAllFICATION AND CERTIFICATION OF NONDESTRUCTIVE EXAMINATION PERSONNEL IN ACCORDANCE WITH ASNT SNT-TC-1A AND SECTION XI l

l A r m e/ d<. a.a. a / d a d d A f S M a

  • D.2. Soba;c/ Art.

/.m /.zic is/a/s7 APPRO APPROVED BY:

gr.s A? d J

G.R. W

/sV.C. LARREW General Manager, W anager, Nuclear Plant Services Plant Services Quality Departmen t g

8808240029 080015 gDR ADOCK 05000353 PNU

.no, n...

..,nn

NUCLEAR PLANT SERVICES DEPART)iENT F0P-03 Field Quality Procedure Revision 01 l'

h~

1.0 Scope 1.1 This procedure establishes the requirements for the

training, qualification and certification of personnel who are responsible for l-perfortnance of 2ndestructive Examination (NDi.).

1.2 This procedure meets the requirements of the knerican Society for i

Nondestructive Testing Recomended Practice SNT-TC-1 A (1980 Edition).

1.3 Additional quali fica tion requirements may exist in other specifications, such as ASME Section !!I, VI!! and XI, MIL-Std 271, NAVSEA 250-1500-1, etc.

The requirements of the other specifications shall take precedence when such differences exist.

Certification for i

special applications shall be documented.

l l'

l.4 This procedure may be supplenented for special requirements of other specifications or documents as required.

b This procedure includes the q' alification and certification process l.

1.5 u

for visual examination (VT) personnel in a manner similar to other l

methods described in SNT-TC-1A.

1.6 Personnel certifications issued prior to the issuance or revision of this procedure shall remain valid until such time as they expire or dre revoked.

I i

2.0 References 2.1 ASNT SNT-TC-1A, knerican Society for Nondestructive Testing Recomended Practice.

2.2 ASME Section XI, !WA-2300.

3.0 Definitiens

3.1 Qualification

Ca pabili ty as indicated by

skill, training and experience required for personnel to properly perform the duties of a t

specific job.

3.2 Certification

Written testimony of qualification.

3.3 Certi fica tion Agency:

General Electric

Ccepany, Nuclear Plant Services Department.

l

3.4 Training

The program developed to impart the knowledge and skills

{

necessary for qualification and certification.

G g'O Date Issued:

June 17,1987 Page 2 of 20

NUCLEAR PLANT SERVICES DEPARTHENT FQP-03 Field Quality Procedure Revision 01 h_

g

3.5 Experience

The knowledge and skill derived from observation and participation in performing a nondestructive examination.

{

3.6 Additional levels of skills or qualifications:

These additional l

levels of skills or qualifications are stated on the certification record.

3.7 Level III Examiner:

The Level III Examiner is appointed by the

Manager, Plant Services Quality and is responsible for the impl ementa tion of this procedure in addition to other specific responsibilities as outlined in this procedure.

3.8 Interrupted Service:

Certified personnel not performing to a

particular NDE method for a period of one year.

4.0 Responsibilities 4.1 The

Fbnager, Plant Services Quality shall appoint level 111 Examiner (s) to implement the duties outlined in this procedure.

4.2 The Level 111 Examiner is responsible for impl ementa tion of the program described herein.

4.3 The Level !!! Examiner for each NDE discipline is responsible for and shall provide guidance and direction for related training and

]f.

qualification.

4.4 Certified personnel are responsible for documenting work experience on a continuing basis.

The record of updated work experience shall be transmitted to the Level Ill Examiner (s) at least annually.

4.5 The

Manager, Plant Services Quality is responsible for the interpretation of this procedure.

4.6 Changes to this procedure will be done in the same manner as the original for review and approval before procedure revision.

5.0 Nondestructive Examination Hethods 5.1 The methods of examination specifically designated in this procedure are:

5.1.1 Liquid Penetrant Examination (PT) 5.1. 2 Magnetic Particle Examination (MT) 5.1.3 Visual Examination (VT) - (VT1/ASHE XI) 5.1.4 Eddy Current Examination (ET) 5.1.5 Ultrasonic Examination (UT) 5.1.6 Leak Testing (LT) 5.1.7 Radiographic Examination (RT)

O l

i Date issued:

June 17,1987 Page 3 of 20 F

NUCLEAR PLANT SERVICES DEPARlHENT FQP-03 h

e ~

Field Quality Procedure Revision 01 h

i gV 6.0 Certification Levels 6.1 There are three levels of certification for each NDE method; however, these levels may be subdivided to identify specific levels of skills i

and responsibilities as defined in paragraphs 6.2.1 and 6.2.4 l

i 6.2 Certification levels shall be consistent with the following criteria:

6.2.1 Trainee 6.2.1.1 A Trainee is an individual who does not have the minimum experience hours required to be certified as a Level 2,

but meets the Level I

education

, training and examination requirements as specified within this procedure,

a. A Trainee shall work with a certified Level I,

11 or 111 individual and shall not independently conduct any test, interpret or evaluate the resul ts of a test, or report test results.

b. When a Trainee has successfully met the minimum experience hours required for a Level 1, he may be certified as a Level I in accordance with Table 1 without further examination.

The new Level 1

O certification shall expire three (3) years from the original trainee certification date.

6.2.2 Level 1

6. 2. 2.1 A Level I meets education, training, examination and experience requirements of the applicable method.

6.2.2.2 A Level 1

is qualified to perform calibration, examinations and record resul ts in accordance with written procedures under the direct supervision of a Level !! or 111.

Unless otheNise prohibited in the applicable code, standard or procedure, a Level I may interpret examination resul ts for the purpose of evaluating acceptability of materials or components.

6.2.3 Level II 6.2.3.1 A Level !! meets education, training, examination and experience requirements of the applicable method.

6.2.3.2 A Level II is qualified to direct and perforn calibrations, examinations, interpret, evaluate and report examination results for determining acceptability of materials and components in accordance with applicable codes, standards and specifications.

A Level

{

Date issued:

June 17,1987 Page 4 of 20

Vb NUCLEAR PLANT SERVICES DEPARTHENT F0P-03 Field Quality Procedure Revision 01 l

p

()

Il shall be familiar with scope and limitation of the method and shall have a

practical background in applicable materials and fabrication processes.

A Level 11 is qualified to prepare written instructions I

and procedures subject to the approval of a Level !!!.

A Level 11 is to provide on-the-j ob training and direction to trainees and Level I personnel.

6.2.4 Level !!!

6.2.4.1 A Level !!! meets education, training, examination and experience requirements of the applicable method.

6.2.4.2 A Level Ill is capable of establishing techniques and procedures; interpreting

codes, standards, specifications and procedures; and designating the particular test methods, techniques, and procedures to be used.

A Level III is responsible for the NDE operations for which qualified and assigned and is capable of interpreting and evaluating results in terms of existing codes, standards and specifications.

A Level 111 shall have sufficient practical background in applicable materials, fabrication, and product technology to establish techniques and to assist in e.

i establishing acceptance criteria where none are j

o thenvi se available.

A Level III shall have general j

f amiliarity with other appropriate NDE methods and is qualified to train and examine other NDE persor.nel.

i 1

7.0 Education, Training and Experience i

7.1 Personnel being certified in NDE shall have sufficient training to ensure understanding of the principles and procedures in those NDE methods in which they are being evaluated.

i l

7.2 Personnel shall have successfully completed classroom training.

7.3 The Education and Employment Record Form (Exhibit 1) is used to h

record the infonnation required by 7.1 and 7.2.

I L

7.4 Training courses shall be conducted by qualified General El ectric l

Company personnel or by other qualified professionals (NDE Schools, i

educational institutions, training seminars, etc. ) as determined by the Manager, Plant Services Quality.

7.5 Education options for Levels I, & II.

7. 5.1 Option 1:

Successful completion of at least two years of engineering or science study in a university, college or technical school.

j' Date Issued:

June 17,1987 Page 5 of 20

~ L,

,()

~

w r (^)

WUCLEAR PLANT SERVICES DEPART)iENT F0P-03

'M V Field Quality Procedure Revision 01 7.5.2 Option 2:

High school graduation, diploma or equivalent.

7.5.3 Option 3: - Gramar school graduation or dcmonstrated proficiency or additional training.

7.6 Education Options and Work Experience for Level 111 t

7.6.1 Option 1:

Graduate of a four year accredited engineering or j

science college or university with a degree in Engineering or science plus one year's experience in nondestructive examination in an assignment comparable to that of a Level 11 in the applicable examination method.

7.6.2 Option 2:

Completion with a passing grade of at least two years of science study at an accredited university, college or technical school plus two years experience as a certified Level 11 in the applicable examination method.

4 7.6.3 Option 3:

Four years experience in an assignment at least comparable to that of a Level 11 in the applicable testino method.

e t,;

G 7.7 Training and Experience Requirements

[

Q I

7.7.1 Minimum training and experience hours for all levels of NPE personnel shall be as defined below and in Table 1 of this procedure.

7.7.2 Work experience is considered to include all the time associated wi th performing an examination.

This includes time spent in preparation, in procedure and technique review, for discussion and specific task instruction, durino actual examination time, for post examination clean up, and for reporting and record keeping.

This does not include training time, which is a separate requirement, nor does it include travel time to the job site.

Work experience shall be recorded as hours of experience on the NDE individual experience record (Exhibit 11).

Note 1. Work experience requirements are expressed in months or hours based on.a normal forty (40) hour work week (175 hours0.00203 days <br />0.0486 hours <br />2.893519e-4 weeks <br />6.65875e-5 months <br /> per month).

When work is performed in excess of a forty (40) hour week, work experience tnay be credited basad on actual hours.

l Note 2. Training and experience credit may be gained in VT by accumulation of training and experience in HT, PT, P.T and UT.

T O n...

,,,,,a.

,,-17 ton 7 Pace 6 of 20

]

1

T

-4

['\\)

-(y 1

,'J

%)

'1 Z

^C 4O e r-CL m TABLE 1 OF PROCEDURE FQP-03 p

o.

o

.[

GENERAL TLECTRIC COMPANY - NUCLEAR PIANT SERVICES DEPARTMENT TRAINING AND EXPERIENCE REQUIREMENTS I{

,. x 1

.l Prr UT PT ET LT (BT)

VT/VT-1 I

P Tl*M.

RT om

LEVEt, S LTION EXP./TRPG.

EX P./TRNG.

EX P. /TRNG.

EXP./TRNG.

EXP./TRNG.

EX P./TRNG. l EXP./TRNG.

3$

n<

]

TRAINEE OPTION 1

- 12 Hrs 8 Itre

- 24 Hrs 4 Hrs 8 Hrs 2 Hrs

- 4 Hrs

$N c res l

OPTION 2

- 20 Hrs

- 12 Hrs

- 40 Hrs 4 Ilts

- 12 Hrs 2 Hrs

- 4 Hrs ro O

2 2

OPTION 3

- 80 Hrs

- 24 Hrs

- 40 lirs

- 12 Hrs

- 48 Hrs 2 Hrs

- 4 Hrs o>

x2 LEVEL I OPTION 1 3 No 12 Hrs'1 Mo t; Mrs 3 Mo 24 firs 1 Mo 4 Ilts 1 Mo 8 Hrs 2 Hrs 2 Hrs 1 Mo 4 Hrs

-j r4 OPTION 2 3 Mo 20 Hrs i Mo 12 firs 3 Mo 40 Itre 1 Mo 4 Hrs 1 Mo 12 Itra 2 Hrs 2 Hrs 1 Mo 4 IIrs

=

~4 1

OPTION 3 3 Mo 80 Hrs 1 Mo 24 Hrs 3 Mo 40 Ilrs 1 Mo 12 Hrs 1 Mo 48 lira 2 Hrs 2 Hrs 1 Mo 4 Hrs i

j LEVEL II OPTION 1 9 Mo 40 Hrs 3 Mo 4 Hrs 9 Mo 40 liro 2 Mo 4 Hrs 9 Mo 8 Hrs 2 Wks 2 Hrs 1 Mo 8 Hrs s.

OPTION 2 9 Mo 40 Hrs 3 Mo 8 Hrs 9 Mo 40 Hra 2 Mo 8 Hrs 9 Mo 8 Hrs 2 Wks 4 Hrs 1 Mo 8 Hrs OPTION 3 9 Mo 80 Hrs 3 Mo 16 Mrs 9 ho 80 liro 2 Mo 16 Hrs 9 Mo 2 4 Hrs 2 wks 4 Hrs 1 Mo 8 Hrs

  • LEVEL III REFER TO PARAGRAPH 7.6.

NOTE: (1) For Imvel II certiflcation the experience should consist of time at Level I or equivalent.

If an individual is being quellfied directly to tevel II with no time at tevel I,

the K and II required experience should consist of the sus of the times required for Levels I and II.

required training should consist of the sum of hours required for tevels and the (2) VT Training and experience specified here applies to NDE personnel and shall not be assumed as a substitute f or ASME VT2, VT3, VT4 and/or ANSI requirements. ASME VT2, VT3, requirements and ANSI requirements are addressed in separate General Electric Company VT4 procedures.

(3) level III education and crperience requirements are defined in Paragraph 7.6 of this procedure.

e 1

4 3

+

4 to a -*g 3

OO 3 m M

OO 3

~* us

  • ^ ' ~

f'\\

O

~

F f'-

NUCLEAR PLANT SERVICES DEPARTHENT F0P-03

" h]

Field Quality Procedure Revision 01 8.0 Examinations 0.1 Vision Test

$skchWI

8.1.1 Physical

All visve' examination personnel shall meet the specified vision acuity requirements both as a prerequisite j

to training, qualification and certification and as a

continuing requirement.

Visual acuity testing shall be

[

performed annually.

a.

An examination shall be administered annually to assure I

l natural or corrected near vision (Jceger J -1, or equivalent, as a minimum in at least one eye) and far i

vision acuity which shall be a Snellen fraction of 20/30, or equivalent, as a minimum.

The examination shall also. include contrast perception (which will determine the capability to resolve a 1/32" black line on an 18% neutral gray card or equivalent) and color perception using an ISilIHARA test or equivalent.

For personnel who are color deficient, a

practical demonstration of color proficiency in the inspections or tests to be performed will be considered sa ti s f ac tory and shall be noted on the vision acuity examination record.

p b.

The vision acuity examination shall be administered by the Level

Examiner, qualified General Electric personnel, optometrists, physicians or nurses, j

8.2 Examinations (Trainees, Levels I and !!)

8.2.1 Examinations for trainees, levels 1, and 11 shall consist of general, specific and practical examinations as outlined in SNT-TC-1 A and described within this procedure and Table 2.

8.2.2 General Examination:

The general examination shall cover theory, principles, and practices relative to the applicable NDE method.

This examination shall be administered without access to reference material (closed book) except that graphs, tables and other necessary data may be used.

8.2.3 Specific Examination:

The specific examination shall cover equipment, operating procedures, examination techniques and codes that the examinee may encounter in specific assignments.

This examination shall be administered with access to necessary da ta such as

graphs, tabl e s,

specifications, procedures and codes.

.(

l

}

(Mte issued:

June 17.1987 Page 8 of 20

NUCLEAR PLANT SERVICES DEPARi}iENT FQP-03 Field Quality Procedure Revision 01 l

i ff *(

8.2.4 Practical Examination:

The Examinee shall demonstrate to the satisfaction of the Level III Examiner familiarity with the opert'lon of the necessary equipment and interpretation of examinnion results to the degree required.

Personnel proficiency shall be demonstrated in performing the t

applicable NDE on one or more samples approved by the Level III Examiner.

At least ten different check points requiring an understanding of examination variables and procedural requirements shall be included in this practical examination.

A description of the examir.ation specimen, procedure, check points and results shall be documented and graded.

TABLE 2 OT PROCEDURI TQP-03 GENERAL LIECTRIC COMPANY - NUCLEAR PLAliT SERVICES DEPARTMENT QUALITICATICH EXAMINATICH RIQUIRIMINTS THIS TABLE CONTAIHS THE MINIMUM NUMBER 01 oVESTIONS TO BE ADMINIsTERID AS INDICATED BY PERS010iEL LEVEL, NDE MITh 3, AND EXAMINATION TYPE.

CERTITICATION LEVEL TRAtttIE AND LEVEL I IEVEL II HITHOD GENERAL SPECITIC GENERAL SPECITIC

,p RADIOGRAPHY (RT) 40 20 40 20 KAGNITIC (MT) 30 20 30 15 PARTICLE TISTING ULTRA 50 HIC (UT) 40 20 40 20 TESTING L10VID PENETRAlfT (PT) 30 20 30 25 TESTING EDDY CURRENT (ET) 30 20 30 20 TESTING LEAF. TESTING -

(LT) 20 15 30 15 e

BUBBLE TEST!HG V2SUAL TESTING (VT) 30 20 30 15 (ASME VT-1).

  • HOTES*

NOTE: (1) PRACTICAL EXAMINATICHS TCR THE LEVELS INDICATED SHALL BE AL l

DESCRIBED IN PARAGRAPH 8.2.4.

NOTE: (2) EXAMINATICH CONTENT SMALL BE AS DESCRIBED IN PARAGRAF_' 8.2.

I i

F Date Issued:

June 17,1987 Page 9 cf 20 1

L

[

F0P-03 NUCLEAR PLANT SERVICES DEPART 14ENT Pevision 01

/

(

Field Quality Procedure E.3 Examinations - Level III 8.3.1 Basic Examination:

A basic examination is required only once when more than one method of examination is taken within a

three year period.

As a minimum the basic examination shall consist of:

Twenty questions relating to understanding the SNT-TC-1 A a.

L document.

b.

Fi f teen questions relating to applicable ma te rial s,

3' fabrication, and product technology.

Fif teen questions which are selected from or are similar U

c.

to published Level 11 questions for other appropridte i

NDE methods, 8.3.2 Method Examination (for each method ):

As a minimum the method examination shall consist of:

Thirty questions relating to fundartentals and principles a.

which are selected from or similar to published ASNT Level III questions for each method, b.

Fifteen questions relating to application and establishment of techniques and procedures sich are selected from or are similar to pubitshed ASNT Level !!!

questions for each methad, Twenty questions relating to capability for interpreting c.

codes, standards, and specifications relating to the method.

8.3.3 Specific Examination (for each method):

As a minimum the specific examination shall consist of twenty questions rela ting to speci fications,

equipment, techniques and procedu:*es applicable to the product and methods employed, to the administration of this procedure.

A composite and grade of 80% is required with no grade less than 70%.

8.4 Grading 8.4.1 The Level III Examiner is responsible for conducting and grading examinotions.

The actual administration and grading of examinations may be delegated.

For Level I, II & III examinations a composite grade of 80',

i.

8.4.2 In addition, each passing grade for j

or greater is required.

l, the general, specific and practical or the basic, method and dc specific examination shall be 70% or greater.

l Page 10 of 20 Date Issued:

Jcr

, 1987

O

. N

)

s h-NUCLEAR PLANT SERVICES DEPARINENT FOP-03 Revision 01 Field Quality Procedure 8.4.3 Test objects shall be used in the practical examinations and at least 90*.

of the known indications shall be found.

l Ac tual production parts may be used as test objects when i

examinations are. administered at work sites and documented on examination forms.

8.4.4 A

percentile weight factor shall be applied to the percentage grades of the various examinations.

The percentile weight assigned any particular examination shall be as listed bel ow.

The total of the three percentile weights shall equal 1.0.

a.

Trainee and Level 1 Percentile Weights 1.

General 0.5 2.

Specific 0.2 3.

Practical 0.3 b.

Level II Percentile Weights 1.

General 0.3 2.

Specific 0.4 3.

Practical 0.3 c.

Level 111 Percentile Weights 1.

Basic 0.4 2.

Fkthod 0.4 3.

Specific 0.2 8.4.5 The composite grade (Cc) is determined as follows:

Ge = (Gb x Wb) + (Gm x Wm) + (Gs x Ws) for Level III Ge = (Gg x Wg) + (Gs x Ws) + (Gp x Wp) for Level !!

Where:

Ge = Composite grade Gb = Actual grade from basic examination in percent Wb = Percentile weight of basic examination Gs = Actual grade from specific examination in percent Ws = Percentile weight of specific examination On = Actual grade from method examination in percent Wm = Percentile weight of method examina^ ion Gg = Actual grade for general examination in percent Wg = Percentile weight of general examination Gp = Actual grade of practical examination in percent Wp = Percentile weight of practical examination

(

Pace 11 of 20

I

'l

[ {)

NUCLEAR PLANT SERVICES DEPARlHENT FOP-03 Field Quality Procedure Revision 01 8.4.6 Exampl e:

1.

Test results obtained for a Level !! examination I

General (Gg)

= 8/%

j Specific (Gs)

= 93%

Practical (Gp)

= 90%

2.

Percentile weight assigned for each examination General (Wg)

= 0.3 Specific (Ws)

= 0.4 Practical (Wp)

= 0.3 3.

Then:

Ge = (87 x 0.3) + (93 x 0.4) + (90 x 0.3)

Gc = 26.1 + 37.2 + 27.0 Ge = 90.3%

8.4.7 All written exams shall be generated by the Level til Examiner and shall be controlled and available to the NDE personnel only while being examined.

if t

8.4.8 Re-examination

Those failing to attain the required grades must wait at least 30 days or show evidence of having received suitable edditional training as determined by the Level 111 Ixaminer.

9.0 Certification 9.1 Certification of NDE personnel is the responsibility of the Territory Manager, Quality Assurance based on the recomendation of the I wi 111 Exaainer.

I 9.2 Certification of NDE personnel is based on demonstration of satisfactory qualification as determined by this procedure.

9.3 Certification records for NDi personnel are maintained in a central file at the territory of fice where issued by the Level !!! Examiner.

The certification records shall contain the following information as l;

a minimum:

a.

Name of certified individual b.

Level of certification and examination method c.

Education background and experience d.

Statement of satisfactory completion for training Results of physical examination (vision acuity) e.

f.

Copies of current examinations, grades for previous examinations s

and description of practical test objects y

i Pace 12 of 20 aa'

i 0d NUCLEAR PLANT SERVICES DEPARTHENT F0P-03 l

Field Quality Procedure Revisior 01 i

g.

Percentile weights assigned i

h.

Composite grades i.

Da te of certification or recertification, date of hire or assignment to NDE activities j.

Signature of Territory Manager Quality Assurance 9.3.1 F. ms exhibited in this procedure shall be used to document the information required in paragraph 9.3.

9.3.2 Personnel who successfully compl ete practical examinations for specialized equipment involving courses or examinations administered by the Electric Power Research Institute (EPRI) shall have such courses noted on their certificates.

Copies shall be kept in files maintained by the Level III Examiner.

Successful completion of such courses are considered as compliance with the requirements of ASME Section XI.

9.3.3 HDE personnel may at any time at the discretion of the Manager, Plant Services Quality have their certification revoked.

9.4 Recertification

Level 1,11 & !!! personnel shall be recertified at p

least once every three years based on retraining and testing.

s 9.5 Personnel not performing to a particular NDE method for a period of one year (interrupted service) shall complete a practical examination in accordance with this procedure.

9.5.1 Sati s f ac tory completion of the practical examination shall continue certification for the period in effect at the time.

9.5.2 Failure to complete the practical examination will require full recertification in accordance with this procedure.

10.0 itrmination 10.1 Certifications are automatically terminated when an employee leaves General Electric Company.

10.2 A tenninated employee may be_ recertified to their fonner level of certification when the following conditions are met:

i

(

a.

Proof of prior certification b.

Work in the capacity to which certified within six months of his termination c.

NDE Level 111 Examiner review of the employees work history since termination d.

Employee satisfactorily completes a practical examination.

7,.

NUCLEAR PLANT SERVICES DEPARTMENT F0P-03 Field Quality Procedure Revision 01 r-

.V 11.0 Exhibits j

1.

Education and Employment Record 11.

Nondestructive Examination Individual Experience Record i

!!!, Certificate of Qualification (Level ! 4 !!)

i

!Y.

Certificate of Qualification (Level !!!)

i V.

Certificate of Training e

VI.

Vision Acuity Record l

E f

l i

O l

l 4

i ro Date Issued: June 17,1987 Page 14 of 20

, ?%

t

(

/

%d NUCLEAR PLANT SERVICES DEPARTHENT FOP-03

,o Revision 01

' ()

Fistis Quality Procedure EXHIBIT 1 0

GENERAL ELECTRIC COMPANY - NUCLEAR PLMIT SERVICES DEPARTMENT EDUCATICH AND DIPLOYMElrF RICORD Page of NAME TITLE DATE I. EDUCATICH: S CHOOL.$, COLLEGES AND COURSES.

HAMI AND 14CATICH OF SCHOOL DATE SUELJECT/HAJOR lio.OT HRS.

GRA0E COMPLETED II. TRAINING q

1

'\\ )

COMP ANY/ ADORISS DISCIPLINE LEVEL CODE /SPECITICATICH DATE RECEIVID III. EXPERIENCE l

l CCKPANY/ADORESS WORK PERTORMED DATES: TROM 70 1

fay /MO./YR.

CAY /MO./YR.

inf ormation contained on this education and einployment record is The true and correct to the best of my knowledge.

SIGH ATURIt S.S.f DATE l

VERITIED BY t TITLEt DATE:

\\s EDUCJ.TIO I

Date issued: June 17,1987 Page 15 Of 20

I l

(^')

NUCLEAR PLANT SERVICES DEPARTHENT FOP-03

'N /

Field Quality Procedure Revision 01 EXHIBIT 11 GENERAL ELECTRIC CCHPANY - NUCLEAR PLANT SERVICES DEPARTHENT INDIVIDUAL EXPERIENCE RECORD Page of NAMEI SSi COMPCNINT $

ACTUAL '10URS FOR EACH DISCIPLINE APPLICABLE DATE PROJECT JOB NO.

PT M

UT RT LT ET VT OTHER/ NOTES I-p',-)

(1) TCTAL-THIS PAGE (2) PRIOR HOURS CRAND M TAL (2)+(2)

The inf ormation on this page is true and correct to the best of my knowledge.

l Signaturei Datet O

ij EXHII

.,. l NUCLEAR PLE T SERYlCES DEPARTNENT

/. O riee ovet> "rocee"re F0P-03 aev4 4o" o' EXHIBIT !!!

L

,i,%dinb?@lNM@d$$@d$NATISIfd9El

. _.. _ _ _ - _ _ _. _ __ _. _ _ _yg.,

CERTIFICATE OF QUALIFICATION f'1 f:

1 a

.I THIS IS TO CERTIFY TliAT

$'d

)

i1 l

l JS ClMLH7ED LY ACCCED.LYCE YlTH TM

?, li y)

L CE/ APSD hDE EL*LVDMTION k CERTH7CA170N

,,'j f

PROCEDl3E FCP-03 Th7CH IS IN CCEPLLLYCE T17H THE RECVL'!LB7S OF

>{\\'t ;'

LVEl!CLv SOCIETY FOR NONDEJ7RUCTBE TEHB'G RECOMADDED PDC 7/CE

not$, J

.D7-1C-1A (1990 Ed)

'i l

1 ay' M

~

rO "t>"oo uvt'

<tannc4no~ o 1t

%24

~

gnl s.~_.._,,___._

1, 1 scoR,.

.-1

, m uc1 g

amm x_.

g i,icinc x_.

pueneit x._. -

s:

coWpostri score

[

5 AD0liloHAL REQUiREWENTS OR LhliTAT10H3:

l g,;

(

l3

0 r

p

.e LJ

9 NUCLEAR PLANT SERVICES DEPARTHENT FQP-03 Field Quality Procedure Revision 01 l

EXHIBIT IV l

\\

i,!

__ $3E@ M E @

4 1

CERTIFICATE OF QUALIFICATION 1

(

Tills IS TO CERTIFY THAT U

ll' j

y IS CCW/7ED LV ACCORDBCE 1178 THE GE/NPSD ADE EuYLVATION & CERTil: CAT 70N PROCEDWE TQP-03 Th7CH IS IN C0kPLlBCE 11TH TRE REQWZJEb75 0F A

AMLUCAN SOCllTY FOR NONDE37ECCT/1T TESTLVG RECWLDDED PR4CiKE i,

Sb7-TC-11 (1993 Ed) l in METHOD llVEL CEPT 1FICAT10N DATE tl

n. cam..,, co mwi=cer--.w

~

l TEST SCORES WildHT PRODUCT L

nASic x e.4 1

WETHODS X 0.4 =

8 SPE lRC I 0.2 =

COWPOSifE SCORE l

l

^

ADDITIONAL REQUIREWENTS CR UWITATIONO.

'I i

D IIVEL II] IXAMLNER TERRITORY WANAGER.QUA11TY ASSURANCE j

7,

-O L

- - - - -J L

I j

QJ NUCLEAR PLANT SERVICES DEPARTHENT FCP-03 Field Quality Procedure Revision 01

/

(

EXHIBIT V Exuv i

l GENEPAL ELECTRIC COMPANY - NUCLEAR PLANT SERVICES DEPARTHENT g

i f

I CERTIFICATE OF TRAINING THIS IS To CERTITY TilAT l

l IlAS SUCCES$nJLLY COMPLETED A fl0UR COURSE IN THE DISCIPLINE OT I

IN ACCORDA.NCE WITH THE GENERAL ELECTRIC COMPANY - NUCLEAR PLANT SERVICES a - l h

DEPARTHEbT TRAINING, QUALIFICATION, AND CERTIFICATION PROGRAM WHICH MEETS THE REQUIREMENTS OF ASNT RECOMMINDED PRAC"TICE SNT-TC-1 A.

LEVEL III EXAMINER DATE TERRITORY MANAGER, QUALITY ASSURANCE DATE l

e fN

( L)

Date issued:

June 17,1987 Page 19 of 20

d NUCLEAR PLANT SERVICES DEPARD4ENT FCP-03 l

Revision C1 Field Quality Procedure

,_s

(

)

N/

EXHIBIT VI l

!i h

CINERAL ELECTRIC COMPANY - NUCLEAR PLA.HT SERVICES DEPARTMENT VISICH ACUITY RICORD Soc.Sec.Ho.

Name Data cf Birth j

Component Jaeger J-1 Right Eye Left Eye Both Eyes Results HEAR VISICH Uncorrected Q

Acceptable TEST Corrected 0

Unacc* Feeble Q Req'd Right Eye L4ft Eye Both Eyes Results VISION Uncorrected Q

Acceptable TIST Cerrected O

Unacceptable Ishihara's Test Method Results COLOR VISICH Cotzentst 0

^ce*Ptabl*

TIST Q

Unacceptible COf(7RAST l

O G.E. Visual Comparator Card Results PERCE PTICH Q

Acceptable TEST 1/32" Line Width Q

Unacceptable List any Restrictions or Corrective Measures Required while Witnessing or Performing Examinations / Inspections:

RISTRICTICHS The Results of This Signed (Employee)

Date RISULTS Visual Acuity Test EXF LAINE D Have Been Explained j

To No.

If No Comments Write None" COMMENTS

~_

Signature Title Date E X)MINE D BY i

l vISIoM

<n

( L]

Date Issued:

June 17,1987 Page 20 of 20

\\

_