ML20151P596

From kanterella
Jump to navigation Jump to search
Change Notice 001 to Rev 3 to Procedure CPP-006, Sample Selection
ML20151P596
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 12/21/1987
From: Schauf J, Zill R
EVALUATION RESEARCH CORP.
To:
Shared Package
ML20151P557 List:
References
CPP-006-01, CPP-6-1, NUDOCS 8804260205
Download: ML20151P596 (2)


Text

r b

I Pegs 1 of 2 FDPiINFORMAT10E ONLY EVALUATION RESEARCH CORPORATION COMANCHE PEAK RESPONSE TEAM PROJECT PROCEDURE FOR QA/QC ISSUE-SPECIFIC ACTION PLAN CHANGE NOTICE NO: 001 PROCEDUPI NO: CPP-006 REVISION:

3 ISSUE DATE:

12-21-87 SAMPLE SELECTION The CPP identified above is hereby changed as shown on the attached page of this notice.

Date:

/M -/7' E 7 Prepared by:

f Approved by:

Date:

/M /6-9 7 On-Site QA Regj;4sentative Approved by:

uu Date:

/2- / P ik7 Q

C Rsview Team Leader

/

/

t 8804260205 880415 PDR ADOCK 05000445 A

DCD

T-ri Ching2 Notica 001 CPP-006 Revision: 3 Page 2 of 2 1.

Page 7, Table 5.2-1, Systems Required for Safe Shutdown Add the following systems:

Reactor Coolar.t System Piping Feedwater - Auxiliary Feedwater Connection to Steam Generators This change was inadvertently omitted from previous revisions to the CPP. The change is a clarification of those systems required for safe shutdown as described in the CPSES FSAR and in the Attachment to Memo QA/QC-RT-2204. This change has no impact on previously performed work.

l l

l l

l l

l l

l 2

l