SAN ON0FRE NUCLEAR GENERATING STATION ENGINEERING PROCEDURE S-V-2.12 September 9,1977 INSERVICE INSPECTION CLASS 2 COMPONENTS I.

OBJECTIVE This procedure defines the inservice inspection requirements for ASME Code Class 2 components at '3an Onofre Unit 1 and assures compliance with Technical Specification 4.7.

Furthermore, it is the intent of this procedure to meet the requirements of ASME Code and Addenda in effect as of July 1,1977 (Reference 1) to the maximum extent practical.

II.

CONDITIONS A.

The examination requirefwnts of this procedure are to be per-formed in compliance with the requirements of Reference 1 to the maximum extent practical.

B.

In accordance with the Class 2 inservice inspection requirements in Section XI, the program delineated herein spans the remaining estimated service lifetime of the plant (30 years). This is a period encompassing January 1, 1978 through December 31, 2007.

This 30 year service lifetime is further segmented into three ten year inspection intervals; the first runs from January 1,1978 to December 31, 1987, the second from January 1, 1988 to December 31, 1997 and the third from January 1, 1998 to December 31, 2007.

C.

The requirements of this procedure are effective for a maximum period of forty (40) months, coumencing on January 1,1978.

Prior to the expiration of the forty (40) month period the inservice inspection program shall be reviewed and revised as necessary, in accordance with the requirements of 10 CFR50.55a(g).

D.

Class 2 components, for the purposes of inservice inspection, are itemized in Tables 2A and 2B of Reference 2.

However, para 9raph IWC-1220 of Section XI exempts certain components from examination where certain conditions are met. These exemptions have been applied to the Class 2 listing in Reference 2 with the result that only those nonexempt components (by paragraph IWC-1220) are listed herein.

8802010195 770928 PDR ADOCK 05000206 P

PDR C

g

~

SAN ON0FRE NUCLEAR GENERATING STATION ENGINEERING PROCEDURE S-V-2.12 Page 2 September 9, 1977 1

III. REQUIREMENTS A.

The attached tables define the schedule for examination of Class 2 components.

B.

The examination categories for each component, as defined in Section XI, are itemized under the list of tables.

C.

Components shall be examined during the refueling outage occurring in the year designated under the column "Inspection Dates". The method of examination shall be as listed under the column headed "Primary Mode of Examination".

D.

The components shall be examined as specified in Table IWC-2520 of Section XI to the maximum extent practical.

E.

Examinations that reveal unacceptable structural defects in a category and in one multiple stream of the system shall be extended to include an additional number (or areas) of components in the same category approximately equal to the number initially examined.

In the event further unacceptable structural defects are revealed, all of the same components in the other multiple streams of the system shall be examined.

F.

Evaluation of flaw indications shall be performed in accordance with the requirements of IWC-3000 of Section XI. L'here acceptance standards for a particular component, examination category, or examination method are not included, evaluation shall be made of any indications detected during any inservice examination that exceed the acceptance standards for materials and welds specified in the Code or Standard applicable to the construction of the component in order to determine disposition.

Such disposition shall be subject to review by the enforcement authority havir.g jurisdiction at the plant site.

l i

G.

Class 2 components included in this procedure shall be subjected to system pressure tests in accordance with Article IWC-5000 at least once toward the end of each 10 year inspection interval. Other Class 2 components (those exempted oy para-graph IWC-1220 of Section XI) shall be subjected to a system pressure test in accordance with the following schedule:

1.

Between 25 and 33-1/3". of the required examinations shall be completed by the expiration of one-third of each 10 year inspection inter val,

~

8 6

~

SAN ONOFRE NUCLEAR GENERATING STATION ENGINEERING PROCEDURE S-V-2.12 September 9, 1977 Page 3 e

2.

Between 50 and 66 2/3% of the required examinations shall be completed by the expir!. tion of two-thirds of each 10 year inspection interval.

3.

The remaining required examinations shall be completed by the end of each 10 year inspection interval.

IV. CORRECTIVE MEASURES Repair of any nonconforming components shall be in accordance with the provisions of IWA-4000 and IWB-4000 of Section XI to the maximum extent practical.

V.

RECORDS Records and reports of inservice inspections shall be prepared and maintained as required by Reference 1.

H.

EXCEPTIONS A.

Components which are known to be inaccessible or have limited accessibility are so noted in the attached tables. These and any other components subsequently determined to be either entirely or partly inaccessible, such that the required examination cannot be perfonned to the required extent, shall be inspected as completely as possible utilizing the primary mode of examination.

Should the component or area be amenable to ex-amination techniques other than the primary mode of examination, these alternate techniques shall be utilized in an effort to ascertain the acceptability of the item.

For instance, if an ultrasonic examination is specified but cannot be perfonned, the feasibility of surface examination shall be investigated.

As a minimum, the area should be visually examined, if at 611 possible.

l l

j

e SAN ONOFRE NUCLEAR GENERATING STATION ENGINEERING PROCEDURE S-V-2.12 Page 4 September 9, 1977 B.

Should it be determined that a weld or component cannot be examined using the primary mode of examination due to technique limitations (i.e., grain boundaries, through wall thicknesses, geometric interferences, etc.), alternate examination techniques shall be utilized, where feasible, in an attempt to determine the acceptability of the component. The data sheet shall i

reflect the reason that it was not possible to examine the component using the primary mode of examination, the alternate examination (s) used and the results.

VII. REFERENCES 1.

American Society of Mechanical Engineers (ASME), Boiler and Pressure Vessel Code,Section XI,1974 edition, in:1uding Addenda through Sumer,1975.

2.

San Onofre Nuclear Generating Station, Unit 1, Classification of ASME Class 1, 2 and 3 Systems and Components, including 1

Addendum 1.

h J. M. Curran Plant Manager 1

1 1

GTH:yc l

l

~

CLASS 2 COMPONENTS LIST OF TABLES TABLE EXAMINATION CATEGORY TITLE C1.1 C-A Pressure Vessel Circumferential Butt Welds C1.2 C-B Pressure Vessel Nozzle to Vessel Welds Cl.3 C-C Pressure Vessel Integrally Welded Supports C1.4 C-D Pressure Vessel Bolting C2.1 C-F, C-G Piping Circumferential Butt Welds Residual Heat Removal Piping:

Category C-F All other Piping:

Category C-G C2.2 C-G Piping Longitudinal Weld Joints in Fittings C2.3 C-G Piping Branch Weld Joints C2.4 C-D Piping Pressure Retaining Bolting C2.5 C-E-1 Piping Integrally Welded Supports C2.6 C-E-2 Piping Support Components C3.1 C-F, C-G Pump Casing Welds - NOT APPLICABLE C3.2 0-0 Pump Pressure Retaining Bolting C3.3 C-E-1 Putnp Integrally Welded Supports C3,4 C-E-2 Pump Suppcrt Components C4.1 C-F, C-G Valve Body Welds - NOT APPLICABLE C4.2 C-D Valve Pressure Retaining Bolting C4.3 C-E-1 Valve Integrally Welded Supports NOT APPLICABLE C4.4 C-E-2 Valve Support Components - NOT APPLICABLE

Page l'[;f 3 '

TABLE C-1.1 PRESSURE VESSEL CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELL INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS STEAM GENERATORS 7' 4" (aprox.)

above vessel bottom (Tube plate to lower barrel)

S.G.

A A2C 3.5 375 1982 Volumetric Note 1 S.G.

B B2C 3.5 375 Volumetric Note 1 S.G.

C C2C 3.5 375 Volumetric Note 1 22' above vessel bottom (Lower barrel to tapered barrel)

S.G.

A A3C 3.5 375 Volumetric Note 1 S.G.

B B3C 3.5 375 1992 Volumetric Note 1 S.G.

C C3C 3.5 375 2002 Volumetric Note 1 27' 5" above vessel bottom (Tapered barrel l

toupperbarrel)

S.G.

A A4C 4.0 428 1979 Volumetric Note 2 S.G.

B B4C 4.0 428 Volumetric Note 2 S.G.

C C4C 4.0 428 2000 Volumetric Note 2

4 e

TABLE C-1.1 (con'd)

PRESSURE VESSEL CIRCUMFERENTIAL BUTT WELDS APPROX.

APPR0X.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAlllNATION REMARKS STEAM GENERATORS (con'd) 40' 6" above vessel bottom (Upper barrel to upper head) 5.G.

A ASC 4.0 428 Volumetric Note 2 S.G.

B B5C 4.0 428 1989 Volumetric Note 2 S.G.

C CSC 4.0 428 Volumetric Note 2 RECIRCULATION HEAT EXCHANGER (hell to Head E-11-2 0.375 75.4 1981 Volumetric Note 3

's ll to Flan 9e E-ll-3 0.375 75.4 1991 Volumetric Note 3 e

EAST RESIDUAL HEAT EXCHANGER Shell to Head E-21A-2 0.375 75.4 1985 Volumetric Note 3 Shell to Flan 9e E-21A-3 0.375 75.4 Volumetric Note 3 WEST RESIDUAL HEAT EXCHANGER Shell to Head E-218-2 0.375 75.4 Volumetric Note 3 Shell to Flan 9e E-218-3 0.375 75.4 1998 Volumetric Note 3

s e

Page 3 cf 3 TABLE C-1.1 (con'd)

PRESSURE VESSEL CIRCUMFERENTIAL BUTT WELDS _

4 APPROX.

APPROX.

WFLD LENGTil PRIMARY WELD TilICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAtlINATI0tl REMARKS REGENERATIVE HEAT EXCHANGER Shell to Tubesheet C-3 1.125 34.5 1979 Volumetric Note 4 Shell to llead C-4 1.125 34.5 Volumetric Note 4 Shell to Tubesheet C-7 1.125 34.5 Volumetric Note 4 Shell to Head C-8 1.125 34.5 1998 Volumetric Note 4 Shell to Tubesheet C-ll 1.125 34.5 Volumetric Note 4 Shell to Head C-12 1.125 34.5 Volumetric Note 4 NOTES:

Minimum 25 inches of weld length to be examined during each inspection unifomly distributed among three Note 1:

areas around the vessel circumference.

Minimum 29 inches of weld length to be examined during each inspection unifomly distributed among three i

Note 2:

areas around the vessel circumference.

Note 3: Minimum 15 inches of weld length to be examined during each inspection unifomly distributed among three areas around the vessel circumference.

Minimum 7 incl.es of weld length to be examined during each inspection unifomly distributed among three Note 4:

areas around the vessel circumference.

1

_

e Pag? I cf 2 TABLE C-1.2 PRESSURE VESSEL N0ZZLE-TO-VESSEL WELDS APPROX.

APPROX.

WELD LENGTil PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCliES)

(INCHES)

DATES EMAllINATION REMARKS STEAM GENERATORS Handholes--8' 6" (approx.) abcVe vessel bottom (180* apart) 5.G.

A South side)

AlN 3.5 37.7 1978 Volametric S.G.

B Westside)

BlN 3.5 37.7 Volumetric S.G.

C South side)

ClN 3.5 37.7 Volumetric Volumetric S.G.

A(Northside)

A2N 3.5 37.7

. 1987 Volumetric S.G.

B (East side)

B2N 3.5 37.7 S.G.

C (North side)

C2N 3.5 37.7 Volumetric feedwater Inlet Nozzle 29'7" (approx.) above vessel bottom S.G.

A A3N 4.0 37.7 Volumetric S.G.

B B3N 4.0 37.7 Volumetric S.G.

C C3H 4.0 37.7 1991 Volumetric Manhole--38' 9" (approx.) above sessel bottom S.G.

A A4N 4.0 75.4 1998 Volumetric S.G.

B B4N 4.0 75.4 Volumetric S.G.

C C4N 4.0 75.4 Volumetric

r -

~

TABLE C-1.2 (ccn'd)

PRESSURE VESSEL N0ZZLE-TO-VESSEL WELDS APPROX.

APPRGX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAf11 NATION REMARKS Steam Outlet 44' (approx.) above vessel bottom S.G.

A ASN 4.0 113 Volumetric S.G.

B BSN 4.0 113 2004 Volumetric S.G.

C CSN 4.0 113 Volumetric RECIRCULATION HEAT EXCHANGER Inlet Nozzle E-11-1

.375 25.1 1982 Volumetric Dutlet Nozzle E-ll-4

.375 25.1 1991 Volumetric EAST RESIDUAL HEAT EXCHANGER Inlet Nozzle E-21A-1

.375 18.9 Volumetric Outlet Nozzle E-21A-4

.375 18.9 1991 Volumetric WEST RESIDUAL HEAT EXCHANGER Inlet Nozzle E-218-1

.375 18.9 1979 Volumetric Dutlet Nozzle E-218-4

.375 18.9 Volumetric

i 4

TABLE C-1.3 Pa9e 1 cf 3 PRESSURE VESSEL INTEGRALLY WELDED SUPPORTS APPR0X.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INC!!ES)

DATES EXAlilNATION REMARKS STEAM GENERATOR A Main Support Connec-A1LL 4.0 24 1979 Surface tion weld 4' 11-1/2" above vessel bottom, 30" East and North Main Support Connec-A2LL 4.0 24 1995 Surface tion weld 4' 11-1/2" above vessel bottom, 90*

East of North Main Support Connec-A3LL 4.0 24 2007 Surface tion weld 4' 11-1/2" above vessel bottom, 210*

East of North Main Support Connec-A4LL 4.0 24.

1987 Surface tion weld 4' 11-1/2" above vessel bottom, 270*

East of North Upper Guide Support Al2LL 2.5 6

1982 Surface surface connection welds (a group of two) 37' 9-5/16" above vessel bottom 240' East of North a

c Pcge 2 cf 3 TABLE C-1.3 (con'd)

PRESSURE VESSEL INTEGRALLY WELDED SUPPORTS APPR0X.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXN11HATION REMARKS STEAM GENERATOR B Main Support Connec-BILL 4.0 24 2001 Surface tion weld 4' 11-1/2" above vessel bottom 30*

East of North Main Support Connec-B2LL 4.0 24 1982 Surface tion weld 4' 11-1/2" above vessel bottom, 150*

East of North Main Support Connec-B3LL 4.0 24 1991 Surface tion weld 4' 11 1/2" above vessel bottom, 210' East of North Main Support Connec-B4LL 4.0 24 1997 Surface tion ueld 4' 11.1/2" above vessel bottom, 330' East of North Upper Guide Support 811LL 2.5 6

1992 Surface surface connection 4 -

welds (a group of 2) 37' 9-5/16" above vessel bottom, O' East of North

Page 3 cf 3 TABLE C-1.3 (con'd)

PRESSURE VESSEL INTEGRALLY WELDED SUPPORTS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCllES)

(INCilES)

DATES EXAMIllAIl0N REMARKS STEAM GENERATOR C Main Support Connec-CILL 4.0 24 2005 Surface tion weld 4' 11-1/2" above vessel bottom, 90*

East of North Main Support Connec-C2LL 4.0 24 1998 Surface tion weld 4' 11-1/2" above vessel bottom, 150*

East of North thin Support Connec-C3LL 4.0 24 1985 Surface tion weld 4' 11-1/2" above vessel bottom, 270*

East of North Main Support Connec-C4LL 4.0 24 1988 Surface tion weld 4' 11-1/2" above vessel bottom 330*

East of North Upper Guide Support C12LL 2.5 6

2002 Surface surface connection welds (a group of 2) 37' 9-5/16" above vessel bottom, 120*

East of North

TABLE C1.4 PRESSURE VESSEL BOLTING APPR0X.

APPROX.

WELD LENGTil PRIMARY WELD TitICKNESS OF WELD INSPECTION MCDE OF DESCRIPTION DESIGNATION (INCHES)

(INCilES)

DATES EXA!!IllATI0fl REMARKS STEAM GENERATORS Manhole Bolting 16 bolts each S.G.

A 1-16 N/A N/A 1978, 1988 Visual & Either Surface Notes 1 & 2 1998 or Volumetric S.G.

B 1-16 N/A N/A 1982,1992 Visual & Either Surface Notes 1 & 2 2002 or Volumetric S.G.

C 1-16 N/A N/A 1985, 1995 Visual & Either Surface Notes 1 & 2 2005 or Volumetric EXCESS LETDOWN HEAT EXCHANGER Head Bolting 12 bolts total 1-4 N/A N/A 1979, 1989 Visual & Either Surface Notes 1 & 2 1998 or Volumetric 5-8 N/A N/A 1984, 1994 Visual & Either Surface Notes 1 & 2 2002 or Volumetric 9-12 N/A N/A 1987, 2004 Visual & Either Surface Notes 1 & 2 2005 or Volumetric Note 1:

Bolting may be examined either in place, under tension, when the connection is disassembled, or when the bolting is removed.

Note 2:

Nondestructive examinations shall be performed on 10% of the bolting in each joint per ten year interval but not less than two bolts or studs per joint. Visual examination shallrover 100% of the bolting.

4

Page 1 Gf 44 TABLE C-2.1 l

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATFS EXAllINATION REMARKS i

EAST 24" MAIN STEAM LINE (LINE NO.1)

Tee to Pipe 1-1 1.0 75.4 1979 Volumetric Pipe to Elbow 1-2 1.0 75.4 Volumetric Elbow to Pipe 1-3 1.0 75.4 1985 Volumetric Pipe to Elbow 1-4 1.0 75.4 Volumetric Elbow to Pipe 1-5 1.0 75.4 Volumetric Penetration to Pipe 1-6 1.0 75.4 1994 Volumetric Pipe to Tee 1-7 1.0 75.4 Volumetric Tee to Pipe 1-8 1.0 75.4 Volumetric Pipe to Valve 1-9 1.0 75.4 Volumetric Valve to Pipe 1-10 1.0 i5.4-Volumetric Pipe to Tee 1-11 1.0 75.4 Volumetric Tee to Pipe 1-12 1.0 75.4 Volumetric Pipe to Elbow PBP 201 1.0 75.4 2000 Volumetric Note 1 Elbow to Pipe 1-13 1.0 75.4 Volumetric 1

I l

P:ge 2 cf 44 t

TABLE C-2.1 (cen'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Pipe to Elbow 1-14 1.0 75.4 Volumetric Elbow to Pipe PBP 202 1.0 75.4 Volumetric Note 1 Pipe to Stop Valve PBP 203 1.0 75.4 2004 Volumetric Note 1 WEST 24" MAIN STEAM LINE (LINE NO. 2)

Tee to Pipe 2-1 1.0 75.4 Volumetric Pipe to Elbow 2-2 1.0 75.4 1981 Volumetric Elbow to Pipe 2-3 1.0 75.4 Volumetric Pipe to Elbow 2-4 1.0 75.4 Volumetric Elbow to Pipe 2-5 1.0 75.4 1985 Volumetric Penetration to Pipe 2-6 1.0 75.4 Volumetric Pipe to Tee 2-7 1.0 75.4 Volumetric Tee to Pipe 2-8 1.0 75.4 Volumetric Pipe to Valve 2-9 1.0 75.4 Volumetric

=

Pcge 3 of 4k TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPR0X.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF REMARKS DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXM1DillI10tl,

Valve to Pipe 2-10 1.0 75.4 1998 Volumetric Pipe to Tee 2-11 1.0 75.4 Volumetric Tee to Pipe 2-12 1.0 75.4 Volumetric Pipe to Elbow PBP-204 1.0 75.4 Volumetric Note 1 Elbow to Pipe 2-13 1.0 75.4 Volumetric Pipe to Elbow 2-14 1.0 75.4 2004 Volumetric Elbow to Pipe PBP-205 1.0 75.4 Volumetric Note 1 Pipe to Stop Valve PBP-206 1.0 75.4 Volumetric Note 1 Note 1:

PBP indicates a Postulated Break Point as identified in "Report on Effects of a Piping System Break Outside the Containment". Weld identiffcation numbers utilized in that report have been retrained in an attempt to avoid confusion.

t i

m

9' TABLE C-2.1 (con'd) l' PIPING CIRCUf1FERENTIAL BUTT WELDS APPR0X.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS WEST 24" MAIN STEAM HEADER IN CONTAINMENT (LINE NO. 6)

Tee to Pipe 6-1 1.0 75.4 Volumetric Pipe to Elbow 6-2 1.0 75.4 1991 Volumetric Elbow to Pipe 6-3 1.0 75.4 Volumetric Pipe to Tee 6-4 1.0 75.4 Volumetric 6

EAST 24" MAIN STEAM HEADER IN CONTAINMENT (LINE NO. 7)

Tee to Pipe 7-1 1.0 75.4 1988 Volumetric t

Pipe to Elbow 7-2 1.0 75.4 Volumetric Elbow to Pipe 7-3 1.0 75.4 Volumetric Pipe to Tee 7-4 1.0 75.4 Volumetric 20" EQUALIZING LINE (LINE NO. 14)

Pipe to Tee PBP-213 0.8 63.0 1982 Volumetric Note 1 Pipe to Tee PBp-214 0.8 63.0 1998 Volumetric Note 1 b

Page 5 cf 44 IABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPR0X.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS 20" LINE FROM STEAM GENERATOR C TO MAIN STEArt HEADER (LINE NO. 3) i i

Nozzle to Elbow 3-1 0.8 63.0 1981 Volumetric Elbow to Pipe 3-2 0.8 63.0 Volumetric Pipe to Elbow 3-3 0.8 63.0 Volumetric Elbow to Pipe 3-4 0.8 63.0 Volumetric Pipe to Tec 3-5 0.8 63.0 Volumetric 20" LINE FROM STEAM GENERATOR A TO MAIN STEAM HEADER (LINE NO. 4)

Nozzle to Elbow 4-1 0.8 63.0 Volumetric Elbow to Pipe 4-2 0.8 63.0 Volumetric Pipe to Elbow 4-3 0.8 63.0 1991 Volumetric Elbow to Pipe 4-4 0.8 63.0 Volumetric Pipe to Tee 4-5 0.8 63.0 Volumetric 1

~

Page 6 cf 44 TABLE C-2.1 (cen'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS 20" LINE FROM STEAM GENERATOR B TO.St4!N STEAM _ HEADER (LINE NO. 5)

Nozzle to Elbow 5-1 0.8 63.0 Volumetric Elbow to Pipe 5-2 0.8 63.0 Volumetric Pipe to Elbow 5-3 0.8 63.0 Volumetric l

Elbow to Pipe 5-4 0.8 63.0 Volumetric Pipe to Tee 5-5 0.8 63.0 2001 Volumetric l

Note 1:

PBP indicates a Postulated Break Point as identified in "Report on Effects of a Piping System Break Outside the Containment". Weld identification numbers utilized in that report have been retrained i,

in an attempt to avoid confusion.

3 b

k

~

TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELOS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS WEST MAIN STEAM RELIEF PIPING Line No. 50 Tee to Pipe PBP-255 1.0 75.4 1981 Volumetric Pipe to Elbow PBP-256 1.0 75.4 Volumetric Elbow to Pipe 50-1 1.0 75.4 Volumetric Pipe to Elbow PBP-257 1.0 75.4 Volumetric Elbow to Pipe ~

50-2 1.0 75.4 Volumetric Pipe to Cap 50-3 1.0 75.4 2001 Volumetric Pip! to Flange PBP-258 0.86 18.8 Volumetric gd.V. No. 1)

Pipe to Flange PBP-259 0.86 18.8 1982 Volumetric (R.V. No. 3)

Pipe to Flange PBP-260 0.86 18.8 Volumetric (R.V. No. 5)

Pipe to Flange P8P-261 0.86 18.8 Volumetric (R.V. No. 7)

Pipe to Flange PBP-262 0.86 18.8 Volumetric (R.V. No. 9)

Page 8 ef 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAt11HATI0fl REMARKS EAST MAIN STEAM RELIEF PIPING Line No. 51 Tee to Pipe PBP-245 1.0 75.4 Volumetric Pipe to Elbow PBP-246 1.0 75.4 Volumetric Elbow to Pipe 51-1 1.0 75.4 Volumetric Pipe to Elbow PBP-247 1.0 75.4 1991 Volumetric Elbow to Pipe 51-2 1.0 75.4 Volumetric Pipe to Cap 51-3 1.0 75.4 Volumetric Pipe to Flange PBP-248 0.86 18.8 Volumetric (R.V. No. 2)

Pipe to Flange PBP-249 0.86 18.8 Volumetric (R.V. No. 4)

Pipe to Flange PBP-250 0.86 18.8 Volumetric (R.V. No. 6)

Pipe to Flange PBP-251 0.86 18.8 1989 Volumetric (R.V.No.8)

Pipe to Flange PBP-252 0.86 18.8 Volumetric (R.V. No. 10)

. _ _ _ =

~

TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS.

APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION. (INCHES)

(INCHES)

DATES

.EXM11HATION REMARKS Line No. 64 Reducer to Valve PBP-263 0.56 18.8 1978 Volumetric (C.V. 77)

Valve to Pipe 64-2 0.72 18.8 Volumetric Pipe to Elbow 64-3 0.72 18.8 Volumetric Elbow to Pipe 64-4 0.72 18.8 Volumetric Pipe to Reducer 64-5 0.72 18.8 Volur.aetric Line No. 62 Reducer to Valve PBP-264 0.56 18.8 Volumetric (C.V. 79)

Valve to Pipe 62-2 0.72 18.8 1988 Volumetric Pipe to Elbow 62-3 0.72 18.8 Volumetric Elbow to Pipe 62-4 0.72 18.8 Volumetric Pipe to Reducer 62-5 0.72 18.8 Volumetric

=w.-

c--

r e

um e e t-9 e--

P:ge 10 of 44 i

TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS 1

APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXA!!INATIDH REMARKS Line No. 65 Reducer to Valve PBP-253 0.56 18.8 Volumetr*c (C.V. No. 76) d Valve to Pipe 65-2 0.72 18.8 Volumetric Pipe to Elbus 65-3 0.72 18.8 1998 Volumetric Elbow ta Pipe 65-4 0.72 18.8 Volumetric Pipe to Reducer 65-5 0.72 18.8 Volumetric Line No. 63 Reducer to Valve PBP-254 0.56 18.4 Volumetric (C.V.No.78)

Valve to Pipe 63-2 0.72 18.8 Volumetric Pipe to Elbow 63-3 0.72 18.8 Volumetric Elbow to Pipe 63-4 0.72 18.8 Volumetric Pipe to Reducer 63-5 0.72 18.8 Volumetric Note: PBP indicates a Postulated Break Point as identified in "Report on Effects of a Piping System Break Outside the Containment". Weld identification numbers utilized in that report have been retrained in an attempt to avoid confusion.

TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE 6F DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAnlNATION REMARKS EAST MAIN STEAM TO REHEATERS (Lines No. 17 & 19)

Pipe to Elbow PBP-207 0.32 25.1 Volumetric Elbow to Pipe 17-2 0.32 25.1 1979 Volumetric Pipe to Elbow PBP-208A 0.32 25.1 Volumetric Elbow to Pipe PBP-2088 0.32 25.1 Volumetric Pipe to Elbow PBP-209A 0.32 25.1 Volumetric Elbow to Pipe PDP-2096 0.32 25.1 Volumetric Pipe to Elbow PBP-501A 0.32 25.1 Volumetric Elbow to Pipe PBP-5018 0.32 25.1 Volumetric Pipe to Elbow PBP-502A 0.32 25.1 1988 Volumetric Elbow to Pipe PBP-5028 0.32 25.1 Volumetric Pipe to Elbow 17-3 0.32 25.1 Volumetric Elbow to Pipe 17-4 0.32 25.1 Volumetric Pipe to Elbow 17-5 0.32' 25.1 Volumetric Elbow to Pipe 17-6 0.32 25.1 2005 Volumetric

,,m r

P;ge 12 cf 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION M00E OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Pipe to Valve 17-8 0.28 18.9 Volumetric Pipe to Reducer 17-9 0.32 25.1 1998 Volumetric Reducer to Elbow 19-1 0.28 18.9 Volumetric Elbow to Pipe 19-2 0.28 18.9 Volumetric Pipe to Valve 19-3 0.28 18.9 1991 Volumetric WESTMAINSEAMTOREHEATERS(LinesNo.18&20)

Pipe to Elbow PBP-210 0.5 31.4 Volumetric Elbow to Pipe 18-2 0.5 31.4 Volumetric Pipe to Elbow PBP-211A 0.5 31.4 Volumetric Elbow to Pipe PBP-2118 0.5 31.4 Volumetric Pipe to Elbow PBP-212A 0.5 31.4 Volumetric Elbow to Pipe PBP-2128 0.5 31.4 1982 Volumetric Pipe to Elbow PBP-601A 0.5 31.4 Volumetric Elbow to Pipe P8P-601B 0.5 31.4 Volumetric Pipe to Elbow PBP-602A 0.5 31.4 1984 Volumetric

. _ _ =

Pc9e 13 cf 44 i

TABLE C-2.1 (con'd)

)

PIPING CIRCtK ERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Elbow to Pipe P8P-6028 0.5 31.4 Volumetric Elbow to Pipe P8P-603A 0.5 31.4 Volumetric Elbow to Pipe P8P-6038 0.5 31.4 2002 Volumetric Pipe to Valve 18-4 0.28 18.9 Volumetric Pipe to Valve 20-2 0.28 18.9 Volumetric Pipe to Reducer 18-5 0.5 31.4 1987 Volumetric i

STEAM DUMP TO CONDENSERS (Line No. 15)

Reducer to Pipe 15-1 0.32 25.1 1978 Volumetric Pipe to Elbow 15-2 0.32 25.1 Volumetric Elbow to Pipe 15-3 0.32 25.1 1988 Volumetric Pipe to Elbow 15-4 0.32 25.1 Volumetric Elbow to Pipe 15-5 0.32 25.1 Volumetric Pipe to 8end 15-6 0.32 25.1 1979 Volumetric Bend to Tee 15-7 0.32 25.1 1998 Volumetric Tee to Elbow 15-8 0.28 18.9 Volumetric

_ _ _ - - = _ _ _.

~

P ge 14 cf 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELQ INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXM11NAT10fl REMARKS Elbow to Bend 15-9 0.28 18.9 Volumetric Bend to Pipe 15-10 0.28 18.9 1989 Volumetric Pipe to Valve 15-11 0.28 18.9 Volumetric Valve to Pipe 15-12 0.28 18.9 2000 Volumetric Pipe to Elbow 15-13 0.28 18.9 Volumetric Elbow to Bend 15-14 0.28 18.9 2002 Volumetric Pipe to Reducer 15-15 0.28 18.9 1992 Volumetric Pipe to Reducer 15-16 0.32 25.1 1982 Volumetric Reducer to Pipe 15-17 0.28 18.9 Volumetric Pipe to Elbow 15-18 0.28 18.9 2007 Volumetric Elbow to Pipe 15-19 0.28 18.9 1995 Volumetric Pipe to Elbow 15-20 0.28 18.9 Volumetric Elbow to Pipe 15-21 0.28 18.9 2000 Volumetric Pipe to Elbow 15-22 0.28 18.9 Volumetric Elbow to Valve 15-23 0.28 18.9 2005 Volumetric Valve to Elbow 15-24 0.28 18.9 Volumetric Elbow to Elbow 15-25 0.28 18.9 Volumetric

Pcge 15 ef 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION H0DE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXM1174ATI0ti REMARKS Elbow to Pipe 15-26 0.28 18.9 1985

Volumetric Pipe to Reducer 15-27 0.28 18.9 1987 Volumetric FEEDWATER PUMP G-3B SUCTION (LINE NO. 317)

Pipe to Valve 317-1 0.375 50.3 1979 Volumetric Pipe to Reducer 317-2 0.375 50.3 Volumetric Reducer to Valve 317-3 0.375 44.0 Volumetric Pipe to Bend 317-4 0.375 50.3 Volumetric

+

Bend to Pipe 317-5 0.375 50.3 Volumetric Pipe to Reducer 317-6 0.375 50.3 Volumetric Reducer to Pipe 317-7 0.365 31.4 2004 Volumetric

/ FEEDWATER PUMP G-3A SUCTION (LINE NO. 318)

Valve to Bend 318-1 0.375 44.0 Volumetric Bend to Bend 318-2 0.375 44.0 Volumetric Bend to Pipe 318-3 0.375 44.0 1985 Volumetric Pipe to Cap 2:8-4 0.375 50.3 Volumetric

Pcgeh6cf44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Pipe to Tee 318-5 0.375 50.3 Volumetric Valve to Tee 318-6 0.375 50.3 Volumetric Tee to Pipe 318-7 0.375 50.3 1991 Volumetric Pipe to Reducer 318-8 0.375 50.3 Volumetric Reducer to Bend 318-9 0.375 44.0 Volumetric Bend to Pipe 318-10 0.375 44.0 Volumetric Pipe to Reducer 318-12 0.375 44.0 1998 Volumetric Reducer to Pipe 318-13 0.363 31.4 Volumetric FEEDWATER PUMP G-38 DISCHARGE (LINE NO. 319)

Pipe to Reducer 319-1 0.60 31.4 1978 Volumetric l

Reducer to Bend 319-2 0.69 37.7 Volumetric Bend to Valve 319-3 0.69 37.7 Volumetric Valve to Pipe 319-4 0.69 37.7 Volumetric Pipe to Cap 319-5 0.69 37.7 1994 Volumetric Pipe to Pipe 319-6 0.69 37.7 Volumetric Pipe to Pipe 319-7 0.69 37.7 Volumetric

Page 17 df 44 '

TABLE C-2.1 (con'd!

PIPING CIRCUMFERENTIAL SUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION RDERKS Valve to Reducer 319-6 0.69 37.7 Volumetric Reducer to Pipe 319-9 0.69 37.7 Volumetric Pipe to Tee 319-10 0.69 37.7 1998 Volumetric Pipe to Valve 319-11 0.69 37.7 Volumetric FEEDWATER PUMP G-3A DISCHARGE (LINE NO. 320)

Pipe to Reducer 320-1 0.60 31.4 Volumetric Reducer to Valve 320-2 0.69 37.7 Volumetric Valve to Pipe 320-3 0.69 37.7 Volumetric Pipe to Tee 320-4 0.69 37.7 1961 Volumetric Tee to Cap 320-5 0.69 37.7 Volumetric Tee to Pipe 320-6 0.69 37.7 Volumetric Pipe to Tee 320-7 0.69 37.7 2002 Volumetric Tee to Reducer 320-8 0.69 37.7 Volumetric Reducer to Valve 320-9 0.75 44.0 Volumetric F

Pa9e 18 cf 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Tec to Pipe 320-10 G.69 37.7 Volumetric 1988 Volumetric Pipe to Valve 320-11 0.69 37.7 FEEDWATER TO STEAM GENERATOR C Valve to Reducer 326-1 0.59 31.4 1978 Volumetric Reducer to Pipe 326-2 C.59 31.4 Volumetric Pipe to Valve PBP-206 0.59 31.4 Volumetric Valve to Valve 326-3 0.59 31.4 Volumetric Valve to Pipe 391-1 0.59 31.4 1989 Volumetric Pipe to Penetration P8P-205 0.5 31.4 Volumetric Pipe to Elbow 391-2 0.5 31.4 Volumetric Elbow to Pipe 391-3 0.5 31.4 Volumetric Pipe to Elbow 391-4 0.5 31.4 Volumetric Elbow to Pipe 391-5 0.5 31.4 2000 Volumetric Pipe to Elbow 391-6 0.5 31.4 Volumetric Elbow to Pipe 391-7 0.5 31.4 Volumetric

~

P 9e 19 cf 44 TABLEC-21(con'd)

PIPING CIRCtW ERENTIAL BUTT WELDS

~

APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXM11 NATION REMARKS Pipe to Elbow 391-8 0.5 31.4 Volumetric Pipe to Reducer 391-9 0.5 31.4 Volumetric Reducer to Nozzle 391-10 0.5 31.4 Volumetric FEEDWATER TO STEAM GENERATOR A Valve to Reducer 325-1 0.59 31.4 1981 Volumetric Reducer to Pipe 325-2 0.59 31.4 Volumetric Pipe to Valve P8P-210 0.59 31.4 Volumetric

~

Valve to Valve 325-3 0.59 31.4 Volumetr1c Valve to Pipe 393-1 0.5 31.4 Volumetric Pipe to Penetration P8P-209 0.5 31.4 Volumetric Pipe to Elbow 393-2 0.5 31.4 Volumetric Elbow to Pipe 393-3 0.5 31.4 2002 Volumetric Pipe to Elbow 393-4 0.5 31.4 Volumetric Elbow to Pipe 393-5 0.5 31.4 Volumetric Pipe to Elbow 393-6 0.5 31.4 Volumetric Elbow to Fipe 393-7 0.5 31.4 Volumetric

l l

age O cf M TABLE C-2.1 (con'd)

PIPING CIRCUHFERENTIAL BUTT WELDS APPR0X.

APPROX.

WELD LENGTH PRIMARY WELD TilICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXN11 NATION REMARKS Pipe to Elbow 393-8 0.5 31.4 Volumetric Pipe to Reducer 393-9 0.5 31.4 Volumetric Reducer to Nczzle 393-10 0.5 31.4 1992 Volumetric FEEDWATER TO STEAM GENERATOR B Valve to Reducer 329-1 0.59 31.4 Volumetric Reducer to Pipe 329-2 0.59 31.4 Volumetric Pipe to Valve 329-3 0.59 31.4 Volumetric Valve to Valve 329-4 0.59 31.4 Volumetric Valve to Pipe 392-1 0.5 31.4 Volumetric Pipe to Penetration PBP-201 0.5 31.4 Volumetric Pipe to Elbow 392-2 0.5 31.4 Volumetric i

Elbow to Pipe 392-3 0.5 31.4 1985 Volumetric Pipe to Elbow 392-4 0.5 31.4 Volumetric Elbow to Pipe 392-5 0.5 31.4 Volumetric Pipe to Elbow 392-6 0.5 31.4 Volumetric Elbcw to Pipe 397.-7 0.5 31.4 2005 Volumetric r

_ _ - - - ~ _ _ _ _ _ -. _

PIge2iof44 TABLE C-2.1 (cen'd)

PIPING CIRCUHFERENTIAL BUTT WELDS APPROX.

APPR0X.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAl1INATION REMARKS Pipe to Elbat 392-8 0.5 31.4 Volumetric Elbow to Pipe 392-9 0.5 31.4 Volumetric Pipe to Elbow 392-10 0.5 31.4 1997 Volumetric Elbow to Pipe 392-11 0.5 31.4 Volumetric Pipe to Elbow 392-12 0.5 31.4 Volumetri Elbow to Reducer 392-13 0.5 31.4 Volumetric Reducer to Nozzle 392-14 0.5 31.4 Volumetric SAFETY INJECTION PIPING Line 6004 Yalve to Pipe 6004-1 0.58 44.0 Volumetric Elbow to Bend 6004-2 0.58 44.0 1981 Volumetric Elbow to Pipe 6004-3 0.58 44.0 Volumetric Pipe to Elbow 6004-4 0.58 44.0 Volumetric Pipe to Elbow 6004-5 0.58 44.0 Volumetric

TABLE C-2.1 (con'd)

Page 22 of 44 PIPING CIRCUMFERENTIAL BUTT WELDS APPR0X.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Line 6005 Valve to Pipe 6005-1 0.58 44.0 1998 Volumetric Pipe to Elbow 6005-2 0.58 44.0 Volumetric 6005-3 Designation not us Elbow to Pipe 6005-4 0.58 44.0 Volucatric Pipe to Elbow 6005-5 0.58 44.0 Volumetric Elbow to Pipe 6005-6 0.58 44.0 Volumetric Pipe to Elbow 6005-7 0.58 44.0 1991 Volumetric Elbow to Pipe 6005-8 0.58 8.4. 0 Volumetric Pipe to Elbow 6005-9 0.58 44.0 Volumetric Elbow to Pipe 6005-10 0.58 44.0 2005 Volumetric j

Line 6006 Valve to Pipe 6006-7 0.43 18.8 Volumetric Pipe to Elbow 6006-8 0.43 18.8 Volumetric Weld cannot be scar from valve side Elbow to Pipe 6006-9 0.43 18.8 Volumetric Pipe to Elbow 6006-10 0.43 18.8 Volumetric

Page 23 of 44 TABLE C-2el (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPR0X.

APPROX.

WELD LENGTH PRIMARY-WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAt11 NATION REMARKS Elbow to Pipe 6006-11 0.43 18.8 Volumetric Pipe to Elbow 6006-12 0.43 18.8 Volumetric Elbow to Pipe 6006-13 0.43 18.8 Volumetric Pipe to Elbow 6006-14 0.43 18.8 1978 Volumetric Elbow to Pipe 6006-15 0.43 18.8 Volumetric Pipe to Elbow 6006-16 0.43 18.8 Volumetric Elbow to Pipe 6006-17 0.43 18.8 Volumetric Pipe to Elbow 6006-18 0.43 18.8 Volumetric 90* of weld inaccessible due to shield wall Elbow to Elbow 6006-19 0.43 18.8 1989 Volumetric Elbow to Pipe 5006-20 0.43 18.8 Volumetric Pipe to Penetration 6006-21 0.43 18.8 Volumetric Pipe to Elbow 6006-22 0.43 18.8 Volumetric Elbow to Pipe 6006-23 0.43 18.8 Volumetric Pipe to Pipe 6006-24 0.43 18.8 1998 Volumetric

Pag $24of44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPR0X.

APPR0X.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMIi4ATION REMARKS Line 6007 Valve to Pipe 6007-7 0.43 18.8 1982 Volumetric Pipe to Elbow 6007-8 0.43 18.8 Volumetric Elbow to Pipe 6007-9 0.43 18.8 Volumetric Pipe to Elbow 6007-10 0.43 18.8 Volumetric Elbow to Pipe 6007-11 0.43 18.6 Volumetric Pipe to Elbow 6007-12 0.43 18.8 19'91 Volumetric Elbow to Pipe 6007-13 0.43 18.8 Volumetric Pipe to Elbow 6007-14 0.43 18.8 Volumetric 90* of weld inaccessibl due to shield wall Elbow to Pipe 6007-15 0.43 18.8 Volumetric Pipe to Elbow 6007-16 0.43 18.8 Volumetric Elbow to Pipe 6007-17 0.43 18.8 Volumetric Pipe to Elbow 6007-18 0.43 18.8 Volumetric Elbow'to Pipe 6007-19 0.43 18.8 Volunetric Pipe to Elbow 6007-20 0.43 18.8 2007 Volumetric Elbow to Pipe 6007-21 0.43 18.8 Volumetric Pipe to Penetration 6007-22 0.43 18.8 Volumetric

Pagm 25 cf 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPR0X.

APPR0X.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Pipe to Elbow 6007-23 0.43 18.8 Volumetric l

Elbow to Pipe 6007-24 0.43 18.8 Volumetric Pipe to Pipe 6007-25 0.43 18.8 Volumetric Line 6008 Valve to Pipe 6008-6 0.43 18.8 Volumetric Pipe to Elbow 6008-7 0.43 18.8 Volumetric Elbow to Pipe 6008-8 0.43 18.8 Volumetric Pipe to Elbow 6008-9 0.43 18.8 1997 Volumetric Elbow to Pipe 6008-10 0.43 18.8 Volumetric Pipe to Elbow 6008-11 0.43 18.8 Volumetric Elbow to Elbow 6008-12 0.43 18.8 Volumetric Elbow to Pipe 6008-13 0.43 18.8 Volumetric Pipe to Elbow 6008-14 0.43 18.8 2001 Volumetric Elbow to Pipe 6008-15 0.43 18.8 Volumetric 90* of weld inaccessible due to electrical conduit Pipe to Penetration 6008-16 0.43 18.8 Volumetric i

Pipe to Elbow 6008-17 0.43 18.8 Volumetric 1

Page 26 of 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPR0X.

APPR0X.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Elbow to Pipe 6008-18 0.43 18.8 Volumetric Pipe to Pipe 6008-19 0.43 18.0 1987 Volumetric SIS RECIRCULATION PIPING Line 6019 Reducer to Pipe 6019-1 0.28 18.8 1978 Volumetric Pipe to Elbow 6019-2 0.28 18.8 Volumetric Elbow to Pipe 6019-3 0.28 18.8 Volumetric Pipe to Elbow 6019-4 0.28 18.8 Volumetric Elbow to Pipe 6019-5 0.28 18.8 1998 Volumetric Pipe to Elbow 6019-6 0.28 18.8 Volumetric Elbow to Pipe 6019-7 0.28 18.8 Volumetric Access restricted due 1 Pipe to Elbow 6019-8 0.28 18.8 Volumetric Elbow to Pipe 6019-9 0.28 18.8 1995 Volumetric Pipe to Elbow 6019-10 0.28 18.8 Volumetric Elbow to Pipe 6019-11 0.28 18.8 Volumetric

Pa92 27 cf 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL 8UTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION H0DE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Pipe to Elbow 6019-12 0.28 18.8 Volumetric Elbow to Pipe 6019-13 0.28 18.8 Volumetric Pipe to Elbow 6019-14 0.28 18.8 1984 Volumetric Elbow to Pipe 6019-15 0.28 18.8 Volumetric Pipe to Flange 6019-16 0.28 18.8 Volumetric Flange to Pipe 6019 17 0.28 18.8 2001 Volumetric Pipe to Elbow 6019-18 0.28 18.8 Volumetric Elbow to Pipe 6019-19 0.28 18.8 Volumetric Pipe to Elbow 6019-20 0.28 18.8 1988 Volumetric Elbow to Valve 6019-21 0.28 18.8 Volumetric Valve to Pipe 6019-22 0.28 18.8 Volumetric Pipe to Reducer 6019-23 0.28 18.8 2005 Volumetric Reducer to Pipe 6019-24 0.28 18.8 Volumetric Pipe to Elbow 6019-25 0.28 18.8 Volumetric Elbow to Pipe 6019-26 0.28 18.8 Volumetric Pipe to Elbow 6019-27 0.28 18.8 Volumetric T

Page 28 of 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS

~

APPROX.

APPR0X.

WELD LENGTH PRIMARY WELD DIAMETER OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Elbow to Pipe 6019-28 0.28 18.8 1987 Volumetric Pipe to Elbow 6019-29 0.28 18.8 Volumetric Elbow to Pipe 6019-30 0.28 18.8 Volumetric Pipe to Flange 6019-31 0.28 18.8 Volumetric Flange to Pipe 6019-32 0.28 18.8 Volumetric Pipe to Elbow 6019-33 0.28 18.8 l'991 Volumetric Elbow to Pipe 6019-34 0.28 18.8 Volumetric Pipe to Elbow 6019-35 0.23 18.8 Volumetric Elbow to Pipe 6019-36 0.28 18.8 Volumetric Pipe to Tee 6019-37 0.28 18.8 Volumetric Line 6018 Reducer to Pipe 6018-1 0.28 18.8 Volumetric i

Pipe to Elbow 6018-2 0.28 18.8 Volumetric Elbow to Pipe 6018-3 0.28 18.8 Volumetric Pipe to Elbow 6018-4 0.28 18.8 Volumetric i

Elbow to Pipe 6018-5 0.28 18.8 Volumetric Pipe to Elbow 6018-6 0.28 18.8 1979 Volumetric Elbow to Pipe 6018-7 0.28 18.8 Volumetric

Page 29 of 44 TABLE C-2.1 (con'd)

PIPING CIRCUttFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Pipe to Elbow 6018-8 0.28 18.8 Volumetric Elbow to Pipe 6018-9 0.28 18.8 Volumetric Pipe to Elbow 6018-10 0.28 18.8 Volumetric Elbow to Pipe 6018-11 0.28 18.8 2000 Volumetric Pipe to Flange 6018-12 0.28 18.8 Volumetric Flange to Pipe 6018-13 0.28 18.8 Volumetric Pipe to Elbow 6018-14 0.28 18.8 1997 Volumetric Elbow to Valve 6018-15 0.28 18.8 Volumetric Valve to Pipe 6018-16 0.28 18.8 Volumetric Pipe to Reducer 6018-17 0.28 18.8 2007 Volumetric Reducer to Pipe 6018-18 0.28 18.8 Volumetric Pipe to Elbow 6018-19 0.28 18.8 Volumetric Elbow to Pipe 6018-20 0.28 18.8 1981 Volumetric Pipe to Elbow 6018-21 0.28 18.8 Volunetric Elbow to Pipe 6018-22 0.28 18.8 Volumetric

TABLE C-2.1 (con'd)

Paga 30 cf 44 PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATI0H (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Pipe to Elbow 6018-23 0.28 18.8 2002 Volumetric Pipe to Elbow 6018-24 0.28 18.8 Volumetric Pipe to Flange 6018-25 0.28 18.8 Volumetric Flange to Pipe 6018-26 0.28 18.8 1985 Volumetric Pipe to Elbow 6018-27 0.28 18.8 Volumetric Elbow to Pipe 6018-28 0.28 18.8 Volumetric Pipe to Elbow 6018-29 0.28 18.8 Volumetric Elbow to Pipe 6018-30 0.28 18.8 Volumetric Pipe to Tee 6018-31 0.28 18.8 1989 Volumetric Line 737 Pipe to Tee 737-1 0.15 25.1 1988 Volumetric Tee to Cap 737-2 0.15 25.1 Volumetric Tee to Pipe 137-3 0.15 25.1 1991 Volumetric Pipe to Flange 737-4 0.15 25.1 Volumetric Pipe to Flange 737-5 0.15 25.1 2005 Volumetric

Page 31 ef 44 TABLE C-2.1 (cen'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPR0X.

WELD LENGTil PRIMARY WELD TilICKNESS OF WELD INS.ZCTION HCDE OF DESCRIPTION DESIGNATION (INCHES)

(INCilES)

DATES EXAllINATION REMARKS Pipe to Elbow 737-6 0.15 25.1 Volumetric Elbow to Pipe 737-7 0.15 25.1 1979 Volumetric Pipe to Valve 737-8 0.15 25.1 Volumetric Valve to Pipe 737-9 0.15 25.1 Volumetric Pipe to Elbow 737-10 0.15 25.1 1981 Volumetric Elbow to Pipe 737-11 0.15 25.1 Volumetric Pipe ~to Elbow 737-12 0.15 25.1 2001 Volumetric Elbow to Pipe 737-13 0.15 25.1 Volumetric Pipe to Elbow 737-14 0.15 25.1 1989 Volumetric Elbow to Pipe 737-15 0.15 25.1 Volumetric Pipe to Elbow 737-16 0.15 25.1 1995 Volumetric Elbow to Pipe 0.15 25.1 Volumetric Inaccessible due tc concrete shield wal Pipe to Elbow 737-17 0.15 25.1 1998 Volumetric Elbow to Elbow 737-18 0.15 25.1 Volumetric Elbow to Pipe 737-19 0.15 25.1 Volumetric Pipe to Elbow 737-20 0.15 25.1 1989 Volumetric Elbow to Pipe 737-21 0.15 25.1 Volumetric 1

TABLE C-2.1 (con'd)

Page 32 of 44 PIPING CIRCUHFERENTIAL BUTT WELDS.

APPROX.

APPR0X.'

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Pipe to Tee 737-22 0.15 25.1 2004 Volumetric Te2 to Tee 737-23 0.15 25.1 Volumetric Tee to Pipe 737-24 0.15 25.1 1982 Volumetric Pipe to Penetration 737-25 0.15 25.1 Volumetric Pipe to Elbow 737-26 0.15 25.1 1985 Volumetric Elbow to Pipe 737-27 0.15 25.1 Volumetric Pipe to Elbow 737-28 0.15 25.1 2005 Volumetric Elbow to Pipe 737-29 0.15 25.1 Volumetric Pipe to Elbow 737-30 0.15 25.1 1992 Volumetric Elbow to Pipe 737-31 0.15 25.1 Volumetric 4

Pipe to Elbow 737-32 0.15 25.1 Volumetric Elbow to Pipe 737-33 0.15 25.1 1997 Volumetric Pipe to Elbow 737-34 0.15 25.1 1997 Volumetric Elbow to Pipe 737-35 0.15 25.1 Volumetric Pipe to Elbow 737-36 0.15 25.1 1987 Volumetric Elbow to Pipe 737-37 O.15 25.1 Volumetric

Pagm 33 of 44' TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELOS_

APPR0X.

APPROX.

PRIMARY WELD LENGTH WELD THICKNESS OF WELD INSPECTION MODE OF EXAMINATION REMARKS DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES Pipe to Elbow 737-38 0.15 25.1 Volumetric Elbow to Pipe 737-39 0.15 25.1 1985 Volumetric Pipe tc Elbow 737-40 0.15 25.1 Volumetric Elbow to Pipe 737-41 0.15 25.1 2002 Volumetric Pipe to Elbow 737-42 0.15 25.1 Volumetric Elbow to Pipe 737-43

0. ' 5 25.1 1978 Volumetric Pipe to Elbow 737-44 0.15 25.1 Volumetric Elbow to Pipe 737-45 0.15 25.1 1994 Volumetric Pipe to Elbow 737-46 0.15 25.1 2007 Volumetric Elbow to Elbow 737-47 0.15 25.1 Volumetric Elbow to Pipe 737-48 0.15 25.1 1984 Volumetric Pipe to Elbow 737-49 0.15 25.1 Volumetric Elbow to Pipe 737-50 0.15 25.1 2000 Volumetric

Page 34 of 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPR0X.

APPR0X.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS RESIDUAL HEAT REMOVAL PIPING Line 5002 Valve to Pipe 5002-10 0.32 25.1 1978 Volumetric Pipe to Tee 5002-11 0.32 25.1 Volumetric Tee to Elbow 5002-12 0.32 25.1 Volumetric Elbow to Reducer 5002-13 0.32 25.1 1988 Volumetric Tee to Pipe 5002-14 0.28 18.8 Volumetric Pipe to Valve!

5002-15 0.28 18.8 2005 Volumetric Valve to Pipe:

5002-16 0.28 18.8 Volumetric Pipe to Reducer 5002-17 0.28 18.8 Volumetric Reducer to Elbow 5002-18 0.32 25.1 1982 Volumetric Elbow to Piper 5002-19 0.32 25.1 Volumetric Pipe to Flange 5002-20 0.32 25.1 1998 Volumetric Line 5038 Reducer to Pipe 5038-1 0.28 18.8 1991 Volumetric Pipe to Valve 5038-2 0.28 18.8 Volumetric

TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPR0X.

APPR0X.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Valve to Pipe 5038-3 0.28 18.8 2002 Volumetric Pipe to Reducer 5038-4 0.28 18.8 Volumetric Reducer to Elbow 5038-5 0.32 25.1 1985 Volumetric Elbow to Pipe 5038-6 0.32 25.1 Volumetric Pipe to Flange 5038-7 0.32 25.1 1995 Volumetric Line 3015 Flange to Pipe 3015-1 0.28 18.8 1981 Volumetric Pipe to Elbow 3015-2 0.28 18.8 1988 Volumetric Elbow to Pipe 3015-3 0.28 18.8 2007 Volumetric Pipe to Elbow 3015-4 0.28 18.8 1984 Volumetric Elbow to Pipe 3015-5 0.28 18.8 1995 Volumetric Pipe to Valve 3015-6 0.28 18.8 1997 Volumetric Valve to Pipe 3015-7 0.28 18.8 1978 Volumetric Pipe to Valve 3015-8 0.28 18.8 1989 Volumetric Valve to Pipe 3015-9 0.28 18.8 1998 Volumetric

P 9e 36 cf 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAi11 NATION REMARKS Pipe to Tee 3015-10 0.28 18.8 1985 Volumetric Tee to Pipe 3015-11 0.28 18.8 1985 Volumetric i

Pipe to Tee 3015-12 0.28 18.8 2005 Volumetric Tee to Pipe 3015-13 0.28 18.8 1992 Volumetric Pipe to Elbow 3015-14 0.28 18.8 1994 Volumetric Elbow to Valve 3015-15 0.28 18.8 1987 Volumetric Valve to Pipe 3015-16 0.28 18.8 2007 Volumetric Pipe to Elbow 3015-17 0.28 18.8 2004 Volumetric i

Elbow to Pipe 3015-18

'O.28 18.8 2000 Volumetric Pipe to Elbow 3015-19 0.28 18.8 1979 Volumetric l

Elbow to Pipe 3015-20 0.28 18.8 2001 Volumetric Line 3016 Flange to Pipe 3016-1 0.28 18.8 1978 Volumetric Pipe to Valve 3016-2 0.28 18.8 1995 Voleatric Valve to Valve 3016-3 0.28 18.8 1985 Volumetric b

- ~

Page 37 cf 44

-l TABLE C-2.1 (con'd) l L

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION H0DE OF DESCRIPTION DESIGNATION (INCllES)

(INCHES)

DATES EXAllINATION REMARKS Valve to Pipe 3016-4 0.28 18.8 2002 Volumetric Pipe to Tee 3016-5 0.28 18.8 1989 Volumetric Line 3019 Tee to Pipe 3019-1 0.28 18.8 1988 Volumetric Elbow to Pipe 3019-2 0.28 18.8 1998 Volumetric Pipe to Elbow 3019-3 0.28 18.8 1991 Volumetric Elbow to Valve 3019-4 0.28 18.8 1979 Volumetric Valve to Pipe 3019-5 0.28 18.8 2005 Volumetric Pipe to Elbow 3019-6 0.28 18.8 1987 Volumetric Elbow to Pipe 3019-7 0.28 18.8 2002 Volumetric Pipe to Elbow 3019-8 0.28 18.8 1984 Volumetric Elbow to Pipe 3019-9 0.28 18.8 1995 Volumetric

. m

Page35of44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS I

APPR0X.

APPROX.

WELD LENGTil PRIMARY WELD TilICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Line 3000 Pipe to Elbow 3000-1 0.28 18.8 1978 Volumetric Elbow to Pipe 3000-2 0.28 18.8 2000 Volumetric

~

Pipe to Elbow 3000-3 0.28 18.8 1989 Volumetric Elbow to Valve 3000-4 0.28 18.3 2002 Volumetric Valve to Tee 3000-5 0.28 18.8 1992 Volumetric Tee to Elbow 3000-6 0.28 18.8 1995 Volumetric Elbow to Reducer 3000-7 0.28 18.8 1981 Volumetric Tee to Pipe 3000-8 0.28 18.8 2007 Volumetric Pipe to Tee 3000-9 0.28 18.8 1987 Volumetric Line 3001 Valve to Elbow 3001-12 0.28 18.8 1992 Volumetric Elbow to Elbow 3001-13 0.28 18.8 1989 Volumetric Elbow to Pipe 3001-14 0.28 18.8 1989 Volumetric Pipe to Tee 3001-15 0.28 18.8 1991 Volumetric i

Tee to Pipe 3001-16 0.28 18.8 1991 Volumetric

TABLE C-2.1 (con'd)

Page 39 cf 44 PIPING CIRCUHFERENTIAL BUTT WELDS 1

APPRGX.

APPROX.

WELD LENGTil PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS Pipe to Valve 3001-17 0.28 18.8 2005 Volumetric Valve to Elbow 3001-18 0.28 18.8 1978 Volumetric Elbow to Elbow 3001-19 0.28 18.8 1978 Volumetric Elbow to Valve 3001-20 0.28 18.8 1985 Volumetric Valve to Pipe 3001-21 0.28 18.8 1985 Volumetric Pipe to Elbow 3001-22 0.28 18.8 1982 Volumetric Elbow to Elbow 3001-23 0.28 18.8 1982 Volumetric Elbow to Valve 3001-24 0.28 18.8 1998 Volumetric Valve to Tee 3001-25 0.28 18.8 1998 Volumetric Tee to Valve 3001-26 0.28 18.8 1987 Volumetric Valve to Elbow 3001-27 0.28 18.8 1987 Volumetric Elbow to Pipe 3001-28 0.28 18.8 2007 Volumetric Pipe to Elbow 3001-29 0.28 18.8 2002 Volumetric Elbow to Pipe 3001-30 0.28 18.8 2002 Volumetric

Page 40 of 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAi11 NATION REMARKS CONTAINMENT SPRAY PIPING (Line No. 734)

Reducer to Pipe 734-1 0.28 18.8 Volumetric Pipe to Elbow 734-2 0.28 18.8 Volumetric Elbow to Pipe 734-3 0.28 18.8 1978 Volumetric Pipe to Elbow 734-4 0.28 18.8 1978 Volumetric Elbow to Pipe 734-5 0.28 18.8 1997 Volumetric Pipe to Valve 734-6 0.28 18.8 Volumetric Valve to Pipe 734-7 0.28 18.8 Volumetric Pipe to Valve 734-8 0.28 18.8 1991 Volumetric Valve to Pipe 734-9 0.28 18.8 1991 Volumetric 4

Pipe to Tee 734-10 0.28 18.8 Volumetric Reducer to Elbow 734-11 0.28 18.8 Volumetric Elbow to Elbow 734-12 0.28 18.8 1998 Volumetric Elbow to Elbow 734-13 0.28 18.8 1998 Volumetric Elbow to Valve 734-14 0.28 18.8 Volumetric Valve to Pipe 734-15 0.28 18.8 Volumetric Pipe to Elbow 734-16 0.28 18.8 Volumetric

Page 41 cf 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPR0X.

APPR0X.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION HDDE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAfIINATION REMARKS Elbow to Pipe 734-17 0.28 18.8 Volumetric Pipe to Valve 734-18 0.28 18.8 2001 Volumetric Valve to Pipe 734-19 0.28 18.8 2001 Volumetric Pipe to Elbow 734-20 0.28 18.8 Volumetric Elbow to Pipe 734-21 0.28 18.8 Volumetric Pipe to Elbow 734-22 0.28 18.8 1989 Volumetric Elbow to Pipe 734-23 0.28 18.8 1989 Volumetric Pipe to Elbow 734-24 0.28 18.8 1995 Volumetric Elbow to Pipe 734-25 0.28 18.8 1995 Volumetric Pipe to Elbow 734-26 0.28 18.8 Volumetric Elbow to Pipe 734-27 0.28 18.8 1985 Volumetric Pipe to Tee 734-28 0.28 18.8 Volumetric Tee to Pipe 734-29 0.28 18.8 Volumetric 734-30 Designation not used 734-31 Designation not used Pipe to Tee 734-32 0.28 18.8 2005 Volumetric Tee to Reducer 734-33 0.28 18.8 Volumetric

P:ge 42 of 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPR0X.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAf11NATI0tl REMARKS

]

Tee to Elbow 734-34 0.28 18.8 Volumetric i

Elbow to Elbow 734-35 0.28 18.8 1985 Volumetric Elbow to Pipe 734-36 0.28 18.8 1985 Volumetric Pipe to Elbow 734-37 0.28 18.8 Volumetric Elbow to Pipe 734-38 0.28 18.8 Volumetric Pipe to Elbow 734-39 0.28 18.8 Volumetric Elbow to Pipe 734-40 0.28 18.8 Volumetric Pipe to Elbow 734-41 0.28 18.8 Volumetric Elbow to Pipe 734-42 0.28 18.8 Volumetric Pipe to Elbow 734-43 0.28 18.8 1981 Volumetric Elbow to Pipe 734-44 0.28 18.8 1981 Volumetric Pipe to Elbow 734-45 0.28 18.8 2005 Volumetric Elbow to Pipe 734-46 0.28 18.8 2005 Volumetric Pipe to Elbow 734-47 0.28 18.8 Volumetric Elbow to Pipe 734-48 0.28 18.8 2007 Volumetric

Pag? 43 cf 44 TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTil PRIMARY WELD TilICKNESS OF WELD INSPECTION H0DE OF DESCRIPTION DESIGNATION (INCHES)

(INCilES)

DATES EXA!!! NATION REMARKS Pipe to Elbow 734-49 0.28 18.8 2007 Volumetric Elbow to Pipe 734-50 0.28 18.8 Volumetric Pipe to Elbow 734-51 0.28 18.8 1987 Volumetric Elbow to Pipe 734-52 0.28 18.8 1987 Volumetric Pipe to Elbow 734-53 0.28 18.8 Volumetric Elbow to Pipe 734-54 0.28 18.8 Volumetric Pipe to Elbow 734-55 0.28 18.8 2004 Volumetric Elbow to Pipe 734-56 0.28 18.8 2004 Volumetric Pipe to Elbow 734-57 0.28 18.8 Volumetric Elbow to Pipe 734-58 0.28 18.8 Volumetric Pipe to Elbow 734-59 0.28 18.8 Volumetric Elbow to Pipe 734-60 0.28 18.8 Volumetric Pipe to Tee 734-61 0.23 18.8 1979 Volumetric Tee to Pipe 734-62 0.28 18.8 1979 Volumetric Pipe to Elbow 734-63 0.28 18.8 Volumetric Elbow to Tee 734-64 0.28 18.8 2000 Volumetric Tee to Pipe 734-65 0.28 18.8 2000 Volumetric

TABLE C-2.1 (con'd)

PIPING CIRCUMFERENTIAL BUTT WELDS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXVIINATION REMARKS Tee to Flange 734-66 0.28 18.8 1997 Volumetric Pipe to Tee 734-67 0.28 18.8 1997 Volumetric Tee to Pipe 734-68 0.28 18.8 Volumetric Pipe to Elbow 734-69 0.28 18.8 1982 Volumetric Elbow to Pipe 734-70 0.28 18.8 1982 Volumetric Pipe to Valve 734-71 0.28 18.8 Volumetric 1

Valve to Pipe 734-72 0.28 18.8 Volumetric Pipe to Elbow 734-73 0.28 18.8 1992 Volumetric Elbow to Pip'e 734-74 0.28 18.8 1992 Volumetric Pipe to Tee 734-75 0.28 18.8 Volumetric Tee to Flan 9e 734-76 0.28 18.8 Volumetric Tee to Pipe 734-77 0.28 18.8 1988 Volumetric Pipe to Valve 734-78 0.28 18.8 1988 Volumetric Valve to Pipe 734-79 0.28 18.8 Volumetric Pipe to Tee 734-80 0.28 18.8 Volumetric i

TABLE C-2.2 PIPING LONGITUDINAL WELD JOINTS IN FITTINGS o

APPR0X.

APPR0X.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCisiS)

(INCHES)

DATES EXAMINATION REMARKS SAFETY INJECTION PIPING Line No. 6004 Long. Welds in Elbow 6004-2L 0.58 60.0 1992 Volumetric Note 1 Long. Welds in Elbow 6004-4L 0.58 60.0 Volumetric Note 1 Line No. 6005 Long. Welds in Elbow 6005-2L 0.58 60.0 Volumetric Note 1 Long. Welds in Elbow 6005-5L 0.58 60.0 1982 Volumetric Note 1 Long. Welds in Elbow 6005-7L 0.58 60.0 Volumetric Note 1 Long. Welds in Elbow 6005-9L 0.58 60.0 2002 Volumetric Note 1 l

Note:

Includes two (2) longitudinal welds per Elbow. Both are to be inspected (total length approx. 60 fr.ches).

o

P ge 1 bf 2 TABLE C-2.3 PIPING BRANCH WELD JOINTS APPROX.

APPROX.

-WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS 10" Main Steam to 18-1 1.0 31.4 1982 Volumetric West Reheaters (Line No. 18) 6" Main Steam 18-3 0.5 18.8 1979 Volumetric Takeoff to Northwest Reheater 6" Main Steam 20-1 0.5 18.8 1989 Volcmetric Takeoff to Southwest Reheater 10" Main Steam 17-1 1.0 31.4 1992 Volumetric to East Reheaters (Line No. 17) 6" Main Steam 17-7 0.5 18.8 1998 Volumetric Takeoff to Northeast Reheater 6" Safety Injection 6006-25 0.58 18.8 1981 Volumetric (Line No. 6006) 6" Safety Injection 6007-26 0.58 18.8 1991 Volumetric (Line No. 6007) 6" Safety Injection 6008-20 0.58 18.8 2001 Volumetric (Line No. 6008) 14" Feedwater Line 318-11 0.375 44.0 1992 Volumetric Branch Weld at East Feedwater Pump (Line No. 318)

Pa9e 2'cf 2 '

TABLE C-2.3 (con'd)

PIPING BRANCil WELO JOINTS APPROX.

APPR0X.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAHINATION REMARKS MAIN STEAM RELIEF VALVES 8 RANCH CONNECTION WELDS West Side R.V. No. 10 52-1 1.0 18.8 Volumetric R.V. No. 8 54-1 1.0 18.8 Volumetric R.V. No. 6 56-1 1.0 18.8 1984 Volumetric R.V. No. 4 58-1 1.0 18.8 Volumetric R.V. No. 2 60-1 1.0 18.8 Volumetric C.V. No. 77 64-1 1.0 25.1 Volumetric C.V. ho. 79 62-1 1.0 25.1 Volumetric East Side R.V. No. 9 53-1 1.0 18.8 Volumetric R.V. No. 7 55-1 1.0 18.8 Volumetric R.V. No. 5 57-1 1.0 18.8 Volumetric R.V. No. 3 59-1 1.0 18.8 Volumetric R.V. No. 1 61-1 1.0 18.8 Volumetric C.V. No. 76 65-1 1.0 25.1 2004 Volumetric i

i C.V. No. 18 63-1 1.0 25.1 Volumetric

=

i TA8LE C-2.4

~

PIPING PRESSURE RETAINING BOLTING APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION f100E OF l

DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS MAIN STEAM RELIEF VALVE FLANGE TO PIPE FLANGE BOLTING i

R.V. I 1 thru 12 N/A N/A 1978, 1988 Visual and either Notes 1 & 2 12 Studs & Double Nuts 1998 Sorface or Volumetric R.V. 2 i thru 12 N/A N/A 1981, 1991 Visual and either Notes 1 & 2 12 Studs & Double Nuts 2001 Surface or Volumetric R.V. 3 1 thru 12 N/A N/A 1985, 1995 Visual and either Notes 1 & 2 12 Studs & Double Nuts 2005 Surface or Volumetric R.V. 4 i thru 12 N/A N/A 1979, 1988 Visual and either Notes 1 & 2 12 Studs & Double Nuts 1998 Surface or Volumetric R.V. 5 1 thru 12 N/A N/A 1982, 1992 Visual and either Notes 1 & 2 12 Studs & Double Huts 2002 Surface or Volumetric R.V. 6 1 thru 12 N/A N/A 1987, 1997 Visual and either Notes 1 & 2 12 Studs & Double Nuts 2007 Surface or Volumetric R.V. 7 1 thru 13 N/A N/A 1982,19rV Visual and either Notes 1 & 2 12 Studs & Double Nuts 2002 Surface or Volumetric R.V. 8 1 thru 12 N/A N/A 1979, 1989 Visual and either Notes 1 & 2 12 Studs & Double Huts 2000 Surface or Volumetric R.V. 9 1 thru 12 N/A N/A 1985, 1995 Visual and either Notes 1 & 2 12 Studs & Double Nuts 2005 Surface or Volumetric R.V. 10 1 thrG 12 N/A N/A 1984, 1994 Visual and either Notes 1 & 2 12 Studs & Double Nets 2004 Surface or Volumetric t

.n

Pcge 2 cf 3 TABLE C-2.4 (con'd)

PIPING PRESSURE RETAINING BOLTING APPROX.

APPROX.

WELD LENGTil PRIMARY WELD TilICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INZilES)

{ INCIIES)

DATES EXAIIINATION REMARKS FEEDWATER LINES AT FEED PUMP SUCTION AND DISCilARGE FLANGES a

Line 317 16 Studs 1-5 N/A N/A 1978, 1988 Visual and either Notes 1 & 2 (1-I/4" Dia.)

1998 Surface or Volumetric 5-10 N/A N/A 1982,.1992 Visual and either Notes 1 & 2 2002 Surface or Volumetric 11-16 N/A N/A 1985, 1995, Visual and either Notes 1 & 2 2005 Surface or Volumetric Line 318 16 Studs 1-5 N/A N/A 1979, 1989 Visual and either Notes 1 & 2 (1-1/4" Dia.)

2000 Surface or Volumetric 6-10 N/A N/A 1981, 1991, Visual and either Notes 1 & 2 2001 Surface or Volumetric 11-16 N/A N/A 1987, 1997 Visual and either Notes 1 & 2 2007 Surface or Volumetric Line 319 16 Studs 1-5 N/A N/A 1978, 1988, Visual and either Notes 1 & 2 (1-1/4" Dia.)

1998 Surface or Volumetric 6-10 N/A N/A 1984, 1994 Visual and either Notes 1 & 2 2004 Surface or Volumetric 11-16 N/A N/A 1985, 1995, Visual and either Notes 1 & 2 2005 Surface or Volumetric

TABLE C-2.4 (con'd)

Pcge 3 cf 3 PIPING PRESSURE RETAINING BOLTING APPROX.

APPR0X.

WELD LENGTil PRIMARY WELD TilICKNESS OF WELD INSPECTION H0DE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAt11tlATION REfMRKS Line 320 16 Studs 1-5 N/A N/A 1979, 1989 Visual and either Notes 1 & 2 (1-1/4" Dia.)

2000 Surface or Volumetric 6-10 N/A N/A 1981, 1991 Visual and either Notes 1 & 2 2001 Surface or Volumetric 11-16 N/A N/A 198'7, 1997, Visual and either Notes 1 & 2 2007 Surface or Volumetric RHR PUMPS SUCTION PIPING Line 5002 16 Studs 1-5 N/A N/A 1978, 1988 Visual & either Notes 1 & 2 (1-1/8" Dia.)

1998 Surface or Volumetric 6-10 N/A N/A 1981, 1991, Visual & either Notes 1 & 2 2001 Surface or Volumetric 11-16 N/A N/A 1985, 1995 Visual & either Notes 1 & 2 2005 Surface or Volumetric Line E038 16 Studs 1-5 N/A N/A 1979, 1989 Visual & either Notes 1 & 2 (1-1/8 Dia.)

2000 Surface or Volunetric I

6-10 N/A N/A 1984, 1994 Visual & either Notes 1 & 2 2004 Surface or Volumetric 11-16 N/A N/A 1987, 1997 Visual & either Notes 1 & 2 2007 Surface or Volumetric Note 1:

Bolting may be examined either in place, under tension, when the connection is disassembled, or when the bolting is removed.

Note 2:

Nondestructive examinations shall be performed on 10% of the bolting in each joint per 10 year

erval, but not less than two bolts or studs per jolat.

Visual examination shall cover 100% of the bolting.

Pcge 1 'cf 10 TABLE C-2.5 PIPING INTEGRALLY WELDED SUPPORTS WELD INSPECTION PRIMARY MODE DESCRIPTION DESIGNATION DATES OF EXAt1IllATI0tl REMARKS MAIN STEAM PIPING Line No. 1 W)" Dia. Horizontal 1-IW 1979, 1989, 2000 Serface Note 1 Pipe Restraint Line No. 2 T6 Dia. Horizontal 2-IW 1985, 1995, 2005 Surface Note 1 Pipe Restraint Line No. 6 Group of Two 6-IW1 1978, 1998 Surface Note 1 12" Dia. Horizontal Pipe Restraint 14" Dia. Vertical Pipe Restraint Sinilar to 6-IW1 above 6-IW2 1981, 2001 Surface Note 1 Similar to 6-IW1 above 6-IW3 1984, 2004 Surface Note 1 Similar to 6-IW1 above 6-IW4 1988 Surface Note 1 Similar to 6-IW1 above 6-IWS 1991, 2007 Surface Note 1 Line No. 7 Similar to 6-IW1 7-IW1 1985 Surface Note 1 above Similar to 6-IW1 7-IW2 1994 Surface Note 1 above Similar to 6-IW1 7-IW3 1995, 2005 Surface Note 1 above

TABLE C-2.5 (con'd)

Pcge 2 cf 10 PIPING INTEGRALLY WELDED SUPPORTS _

WELD INSPECTION PRIMARY MODE DESCRIPTION DESIGNATION DATES

'EXAllINATION REMARKS Similar to 6-IW1 7-IW4 1987, 1997 Surface Note 1 above Line No. 15 3" Dia. Vertical 15-IW1 1985, 1995, 2005 Surface Note 1 Pipe Support 3" Dia. Vertical 15-IW2 1981, 1991, 2001 Surface Note 1 Pipe Support Line No. 50 24" Dia. Horizontal 50-IW1 1979, 2000 Surface Note 1 Pipe Support Similar to 50-IW1 50-IW2 1989 Surface Note 1 above Similar to 50-IW1 50-IW3 1982, 2002 Surface kate 1 above Line No. 51 Similar to 50-IW1 51-IW1 1992 Surface Note 1 above Similar to 50-IW1 51-IW2 1985, 2005 Surface Note 1 above

Pa9e 3'ef 10 '

TABLE C-2.5 (con'd)

PIPING INTEGRALLY WELDED SUPPORTS WELD INSPECTION PRIMARY MODE DESCRIPTION DESIGNATION DATES OF EXM11NATI0f REMARKS Similar to 50-IW1 51-IW3 1995 Surface Note 1 above FEEDWATER PIPING Line No. 317 Ilanger Lugs a group of 2 317-IW1 1979, 1989, 2000 Surface Note 1 Line No. 318 6" Dia. Vertical 318-IW1 1982, 1992, 2002 Surface Note 1 Pipe Support Vertical Support 318-IW2 1979, 1989, 2000 Surface Note 1 Line No. 319 Vertical Support 319-IW1 1979, 1989, 2000 Surface Note 1 Line No. 320 Hanger Lug 320-IW1 1982, 1992, 2002 Surface Note 1 Line No. 391 6" Dia. Vertical 391-IW1 1985, 1995, 2005 Surface Note 1 Pipe Support

~

TABLE C-2.5 (con'd)

PIPING INTEGRALLY WELDED SUPPORTS WELD INSPECTION PRIMARY MODE DESCRIPTION DESIGNATION DATES OF EXAllII4ATION REMARKS 10" Dia. Vertical 391-IW2 1982, 1992, 2002 Surface Note 1 Pipe Support 8" Dia. llorizontal 391-IW3 1981, 1991, 2001 Surface Mate 1 Pipe Support Line No. 392 6" Dia. Vertical 392-IW1 1978,1$88,1998 Surface Note 1 Pipe Support 8" Dia. Vertical 392-IW2 1978, 1998 Surface Note 1 Pipe Support 8" Dia. Vertical 392-IW3 1988 Surface Note 1 Pipe Support 8" Dia. Vertical 392-IW4 1987 Surface Note 1 Pipe Support 10" Dia. Vertical 392-IWS 1984, 1994, 2004 Surface Note 1 Pipe Support 8" Dia. Vertical 392-IW6 1985, 2005 Surface Note 1 Pipe Support 8" Dia. Vertical 392-IW7 1979, 2000 Surface Note 1 Pipe Support 8" Dia. Vertical 392-IW8 1991 Surface Note 1 Pipe Support

Pa9e 5'er ID' TABLE C-2.5 (con'd)

PIPING INTEGRALLY WELDED SUPPORTS WELD INSPECTION PRIMARY MDDE DESCRIPTION DESIGNATION DATES Of EXtJillit.TI0ff REMARKS 8" Dia. Horizontal 392-IW9 1992 Surface Note 1 Pipe Support 8" Dia. Vertical 392-IW10 1981, 2001 Surface Note i Pipe Support 8" Dia. Horizontal 392-IW11 1989, 1995 Surface Note 1 Pipe Support s

Line 393 6" Dia. Vertical 393-IW1 1982, 1992, 2002 Surface Note 1 Pipe Support 8" Dia. Vertical 393-IW2 1997 Surface Note 1 Pipe Support 8" Dia. Horizontal 393-IW3 1984, 2004 Surface Note 1 Pipe Support e

Ptge 6 cf 10 TABLE C-2.5 (con'd)

PIPING INTEGRALLY WELDED SUPPORTS WELD INSPECTION PRIMARY MODF DESCRIPTION DESIGNATION DATES OF EXAMINATION REMARKS SAFETY INJECTION PIPING Line 6004 Grouping of 6004-IW1 1978, 1998 Surface Note 1 8 restraint lugs (4 lugs each side of restraint ring)

Similar to 6004-IW1 6004-IW2 1988, 2007 Surface Note 1 above Similar to 6004-IW1 6004-IW3 1981, 2001 Surface Note 1 above Similar to 6004-IW1 6004-IW4 1982, 2002 Surface Note 1 above Grouping of 6004-IWS 1981, 1991, 2001 Surface Note 1 12 restraint lugs (6 ings each side of restraint ring)

Line 6005 6" Dia. Vertical 6005-IW1 1979, 1989, 2000 Surface Note 1 Pipe Support Grouping of 6005-IW2 1991 Surface Note 1 8 restraint lugs (4 each side of restraint ring)

Similar to 6005-IW2 6005-IW3 1985, 2005 Surface Note 1 above i

c9e 7 cf 10 TABLE C-2.5 (con'd)

PIPING INTEGRALLY WELDED SUPPORTS e

WELD INSPECTION PRIMARY MODE DESCRIPTION DESIGNATION DATES OF EXAtill4ATI0i; REMARKS Similar to 6005-IW2 6005-IW4 1992 Surface Note 1 above Similar to 6005-IW2 6005-IWS 1987, 1997 Surface Note 1 above Similar to 6005-IW2 6005-IW6 1995 Surface Note 1 above Line 6006 Grouping of 6006-IW1 1978 Surface Note 1 8 restraint logs Hanger Lug 6006-IW2 1979 Surface Ncte 1 Surface Note 1 Hanger Lug 6006-IW3 Line 6007 Grouping of 6007-IW1 1978, 1988, 1998 Surface Note 1 4 restraint lugs Grouping of 6007-IW2 1988 Surface Note 1 8 restraint lugs Hanger Lug 6007-IW3 1989 Surface Note 1 m

=

9' TABLE C-2.5 (cen'd)

PIPING INTEGRALLY WELDED SUPPORTS WELD INSPECTION PRIMARY MDDE DESCRIPTION DESIGNATION DATES OF EXAllINATION REKARKS Line 6008 Grouping of 6008-IW1 1998 Surface Mote 1 8 restraint lugs Hanger Lu9 6008-IW2 2000 Surface Note 1 SIS RECIRCULATION PIPING Line 6018 Support Lug 6018-IW1 1979, 2000 Surface Note 1 3" Dia. Vertical 6018-IW2 1978, 1998 Surface Note 1 Pipe Support 3" Dia. Vertical 6018-IW3 1985, 2005 Surface Note 1 Pipe Support Line 6019 Support Lug 6019-IW1 1989 Surface Note 1 3" Dia. Vertical 6019-IW2 1988 Surface Note 1 Pipe Support 3" Dia. Vertical 6019-IW3 1995 Surface Note 1 Pipe Support

TABLE C-2.5 (con'd)

PIPING INTEGRALLY WELDED SUPPORTS WELD INSPECTION PRIMARY MODE DESCRIPTION DESIGNATI0t!

DATES OF EXAlllflATI0l!

REMARKS Line 737 4" Dia. Vertical 737-IW1 1979,1989,2dOO Surface Note 1 Pipe Support RESIDUAL HEAT REMOVAL PIPING Line 3015 Support Lug 3015-IW1 1978, 1988, 1998 Surface Note 1 Support Lug 3015-IW2 1981, 1991, 2001 Surface Note 1 Support Lug 3015-IW3 1984, 1994, 2004 Surface Note 1 Support Lug 3015-IW4 1985, 1995, 2005 Surface Note 1 Line 3019 Support Lug 3019-IW1 1987, 1997, 2007 Surface Note 1 Line 3001 Grouping of 3001-IW1 1979, 1989, 2000 Surface Note 1

~

4 restraint lugs

-~

_ _ _ _ _ _ _= ___. _

TABLE C-2.5 (con'd)

PIPING INTEGRALLY WELDED SUPPORTS s-WELD INSPECTION PRIMARY MODE DESCRIPTION DESIGNATION DATES OF EXAHINATION REMARKS CONTAINHENT SPRAY PIPING Line 734 Vertical Pipe 734-IW1 1978, 1988, 1998 Surface Note 1 Support Lug Support Lug 734-IW2 1982, 1992, 2002 Surface

, Note 1 Welds (Group of 2) 4" Dia. Vertical 734-IW3 1984, 1994, 2004 Surface Note 1 Pipe Support Support Lug 734-IW4 1985, 1995, 2005 Surface Note 1 Welds (Group of 2)

Vertical Pipe 734-IWS 1987, 1997, 2^07 Surface Note 1 Support Note 1: Additionally, visual examination of attachment members, snubbers, support components, etc. shall be included as part of the examination requirements.

The visual examination areas shall include the support components that extent from the attachment to and including the attachment to the supporting structure.

1

Page 1 cf'12 TABLE C-2.6 PIPING SUPPORT COMPONENTS WELD INSPECTION PRIMARY MODE DESCRIPTION DESIF"~.. ION DATES OF EXA!!IllATION REMARKS MAIN STEAM PIPING Line No. 1 Restraint 1-R1 1978, 1998 Visual Restraint 1-R2 1988, 1997 Visual Restraint I-R3 1985, 2005 Visual Restraint 1-R4 1979, 2000 Visual Restraint 1-RS 1989 Visual Restraint 1-R6 1981, 2001 Visual Restraint 1-R7 1991 Visual Line No. 2 Restraint 2-R1 1987, 2007 Visual Restraint 2-R2 1995 Visual Restraint 2-R3 1982, 2002 Visual Restraint 2-R4 1992 Visual Restraint 2-R5 1984, 2004 Visual Restraint 2-R6 1994 Visual Restrair.t 2-R7 1985, 2005 Visual l

i

Page 2 ef 12 TABLE C-2.6 (con'd)

PIPING SUPPORT COW ONENTS WELD INSPECTION PRIMARY MODE DESCRIPTION DESIGNATION DATES OF EXMilNA, TION REMARKS Restraint 2-R8 1995 Visual Line No. 3 Restraint 3-R1 1982 Visual Line No. 4 Restraint 4-R1 1992 Visual Line No. 5 Restraint 5-R1 2002 Visual Line No. 18 Restraint 18-R1 1978, 1988, 1998 Visual Restraint 18-R2 1981, 1991, 2001 Visual Restraint 18-R3 1984, 1994, 2004 Visual Restraint 18-R4 1985, 1995, 2005 Visual Restraint 18-R5 1987, 1997, 2007 Visual

Pt9e 3 cf 12 TABLE C-2.6 (con'd)

PIPING SUPPORT COPPONENTS WELD INSPECTION PRIMARY MODE DESCRIPTION DESIGNATION DATES OF EXAMill&Il0N REMARKS Line No. 15 Restraint 15-R1 1979, 1989, 2000 Visual Restraint 15-R2 1985, 1995, 2005 Visual Line No. 17 Restraint 17-R1 1978, 1988, 1998 Visual Restraint 17-R2 1981, 1991, 2001 Visual Restraint 17-R3 1985, 1995, 2005 Visual Restraint 17-R4 1979, 1989, 2000 Visual Restraint 17-R5 1982, 1992, 2002 Visual Restraint 17-R6 1987, 1997, 2007 Visual l

FEEDWATER PIPING l

l l

Line No. 319 Restraint 319-R1 1982 Visual Line No. 318 Restraint 318-R1 1992 Visual

\\

P:ge 4 Ef 12 TABLE C-2.6 (con'd)

PIPING SUPPORT COMPONENTS WELD INSPECTION PRIMARY MODE DESCRIPTION DESIGNATION DATES OF EXAMINATION REMARKS Line No. 320 Restraint 320-R1 2002 Visual Line No. 391 Restraint 391-R1 1988 Visual Restraint 391-R2 2000 Visual Restraint 391-R3 1978 Visual Restraint 391-R4 2002 Visual Restraint 391-R5 1991 Visual Restraint 391-R6 2004 Visual Restraint 391-R7 1979 Visual Line No. 392 Restraint 392-R1 1995 Visual Restraint 392-R2 1982 Visual Restraint 392-R3 2005 Visual Restraint 392-R4 1984 Visual

~

TABLE C-2.6 (con'd)

PIPING SUPPORT COMPONENTS WELD INSPECTION PRIMARY MODE DESCRIPTION DESIGNATION DATES OF EXAMINATION REMARKS Line No. 393 Restraint 393-R1 2007 Visual Restraint 393-R2 1985 Visual Restraint 393-R3 1997 Visual Restraint 393-R4 1994 Visual Restraint 393-RS 1987 Visual Restraint 393-R6 1998 Visual Restraint 393-R7 1989 Visual SAFETY INJECTION PIPING Line No. 6004 Restraint 6004-R1 1978, 1998 Visual Restraint 6004-R2 1995 Visual Restraint 6004-R3 1982, 2002 Visual Restraint 6004-R4 1988, 2007 Visual Restraint 6004-R5 1994 Visual Restraint 6004-R6 1979, 2000 Visual Restraint 6004-R7 1987, 1997 Visual

~

TABLEC-2.6(con'd)

PIPING SUPPORT COMPONENTS WELD INSPECTION PRIMARY MDDE DESCRIPTION DESIGNATION DATES OF EXAMINATION REMARKS Line 6005 Restraint 6005-R1 1985, 2005 Visual Restraint 6005-R2 1992 Visual Restraint 6005-R3 1984, 2004 Visual Restraint 6005-R4 1989 Visual Line 6006 Restraint 6006-R1 1998 Visual Restraint 6006-R2 1981 Visual Restraint 6006-R3 1998 Visual Restraint 6006-R4 1988 Visual Restraint 6006-R5 1988 Visual Restraint 6006-R6 1991 Visual Restraint 6006-R7 1991 Visual Ralrair.t 6006-R8 2000 Visual Restraint 6006-R9 2007 Visual Y Restraint 6006-R10 1984 Visual Restraint 6006-Ril 2007 Visual

TABLE C-2.6 (con'd)

PIPING SUPPORT COMPONENTS WELD INSPECTION PRIMARY' MODE DESCRIPTION DESIGNATION DATES OF EXAMINATION REMARKS Restraint 6006-R12 Visual 1

Restraint 6006-R13 1992 Visual i

Restraint 6006-R14 1994 Visual Line 6007 Restraint 6007-R1 1979 Visual Restraint 6007-R2 2001 Visual Restraint 6007-R3 1982 Visual Restraint 6007-R4 2002 Visual Restraint 6007-RS 1989 Visual Restraint 6007-R6 2005 Visual Restraint 6007-R7 1979 Visual Restraint 6007-R8 2002 Visual Restraint 6007-R9 1985 Visual Restraint 6007-R10 1985 Visual

._~

~

TABLE C-2.6 (con'd)

PIPING SUPPORT COMPONENTS WELD INSPECTION PRINARY MODE DESCRIPTION DESIGNATION DATES OF E_XAMINATION REMARKS L1ne 6008 Restraint 6008-R1 1987 Visual Restraint 6008-R2 2004 Visual Restraint 6008-R3 2005 Visual Restraint 6008-R4 1982 Visual Restraint 6008-R5 1995 Visual Restraint 6008-R6 1995 Visual Restraint 6008-R7 1987 Visual Restraint 6008-R8 1997 Visual Restraint 6008-R9 1978 Visual Restraint 6008-R10 1997 Visual

~

SIS RECIRCULATION PIPING Line 6018 Restraint 6018-R1 1981, 2001 Visual Restraint 6018-R2 1991 Visual u

9' ' '

TABLE C-2.6 (con'd)

PIPING SUPPORT COMPONENTS WELD INSPECTION PRIMARY MODE DESCRIPTION DESIGNATION DATES OF.EXAMIIMTION REMARKS Line 6019 Restraint 6019-R1 1985, 2005 Visual Restraint 6019-R2 1995 Visual Line 737 Restraint 737-R1 1981, 1991, 2001 Visual Restraint 737-R2 1979, 1989, 2000 Visual Restraint 737-R3 1982, 1992, 2002 Visual Restraint 737-R4 1979, 1989, 2000 Visual Restraint 737-R5 1984, 1994, 2004 Visual Restraint 737-R6 1987, 1997, 2007 Visual Restraint 737-R7 1984, 1994, 2004 Visual Restraint 737-R8 1987, 1997, 2007 Visual Restraint 737-R9 1985, 1995, 2005 Visual Restraint 737-R10 1978, 1988, 1998 Visual Restraint 737-R11 1982, 1992, 2002 Visual Restraint 737-R12 1987, 1997, 2007 Visual Restraint 737-R13 1985, 1995, 2005 Visual Restraint 737-R14 1978, 1988, 1998 Visual

~

TABLE C-2.6 (con'd)

PIPING SUPPORT COMPONENTS WELD INSPECTION PRIMARY MODE

_ DESCRIPTION DESIGNATION DATES OF EXM11 NATION REMARKS Restraint 737-R15 1985, 1995, 2005 Visual Restraint 737-R16 1981, 1991, 2001 Visual Restraint 737-R17 1979, 1989, 2000 Visual RESIDUAL HEAT REMOVAL LINES Line 5002 Restraint 5002-R1 1978, 1988, 1998 Visual Restraint 5002-R2 1982, 1992, 2002 Visual Restraint 5002-R3 1985, 1995, 2005 Visual Restraint 5002-R4 1987, 1997, 2007 Visual i

Line 5f-38 Restraint 5038-R1 1979, 1989, 2000 Visual Restraint 5038-R2 1985, 1995, 2005 Visual i

J

TABLE C-2.6 (con'd)

PIPING SUPPORT COMPONENTS WELD INSPECTION PRIMARY MODE DESCRIPTION DESIGNATION DATES OF EXAMINATION REMARKS CONTAINMENT SPRAY PIPING Line 734 Restraint 734-R1 1978, 1988, 1998 Visual Restraint 734-R2 1984, 1994, 2004 Visual Restraint 734-R3 1978, 1988. 1998 Visual Restraint 734-R4 1985, 1995, 2005 Visual Restraint 734-R5 1982, 1992, 2002 Visual Restraint 734-R6 1979, 1989, 2000 Visual Restraint 734-R7 1981, 1991, 2001 Visual Restraint 734-R8 1985, 1995, 2005 Visual Restraint 734-R9 1987, 1997, 2007 Visual Restraint 734-R10 1981, 1991, 2001 Visual 4

Restraint 734-R11 1978, 1988, 1998 Visual Restraint 734-R12 1985, 1995, 2005 Visual Restraint 734-R13 1979, 1989, 2000 Visual Restraint 734-R14 1987, 1997, 2007 Visual

9e c

2 TABLE C-2.6 (con'd)

PIPING SUPPORT COMPONENTS WELD INSPECTION PRIMARY PODE DESCRIPTION DESIGNATION DATES OF EXAMINATION K MARKS Restraint 734-R15 1984, 1994, 2004 Visual Restraint 734-R16 1987, 1997, 2007 Visual Restraint 734-R17 1982, 1992, 2002 Visual Restraint 734-R18 1979, 1989, 2000 Visual I

m.

m

TABLE C-3.2 9*

PiletP PRESSURE RETAINING BUTTING APPROX.

APPR0X.

WELD LENGTil PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNMION (INCHES)

(INCllES)

DATES EXAllINATION ROMRKS FEEDWATER PUMPS East F.P. (G-3A) 1-7 N/A N/A 1978, 1998 Visual and either Notes 1 & 2 casing studs and Surface or Volumetric nuts (set of 23) 8-15 N/A N/A 1982, 1992 Visual and either Notes 1 & 2 i

Surface or Volumetric 16-23 N/A N/A 1985, 2005 Visual and either Notes 1 & 2 Surface or Volumetric West F.P. (G-3B) 1-7 N/A N/A 1989 Visual and either Notes 1 & 2 casing studs a'nd Surface or Volumetric nuts (set of 23) 8-15 N/A N/A 1994 Visual and either Notes 1 &

Surface or Volumetric 16-23 N/A N/A 1997 Visual and either Notes 1 & 2 Surface or Volumetric RESIDUAL HEAT REMOVAL PUMPS East RilR pp. (G-14A) 1-5 N/A N/A 1979, 2000 Visual and either Notes 1 & 2 casing studs and nuts Surface or Volumetric (set of 16) 6-11 N/A N/A 1984, 2004 Visual and either Notes 1 & 2 Surface or Volumetric 12-16 N/A N/A 1987, 2007 Visual and either Notes 1 & 2 Surface or Volumetric West RHR pp (G-148) 1-5 N/A N/A 1968 Visual and either Notes 1 & 2 casing stusts and Surface or Volumetric nuts (set of 16) 6-11 N/A N/A 1992 Visual and either Notes 1 & 2 Surface or Volumetric 12-16 N/A N/A 1995 Visual and either Notes 1 & 2 Surface or Volumetric

P ge 2 of 2

~

TABLE C3.2 (con'd)

PUMP PRESSURE RETAINING BOLTING NOTES Note 1:

Bolting may be examined either in place, under tension, when th'e connection is disassembled, er when bolting is removed.

Note 2:

Nondestructive examination shall be performed on 10% of the bolting in each joint, per ten year interval but not less than two bolts or studs per joint. Visual examination shall cover 100% of the bolting.

i l

TABLE C-3.3 Pa9e 1 of 2 PLMP INTEGRALLY WELDED SUPPORTS APPROX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATI0tl REMARKS FEEDWATER PUMPS East pump (G-3A)

N/A N/A 1982, 2002 Surface all supports West pump (G-38)

N/A N/A 1992 Surface all supports RESIDUAL HEAT REMOVAL PUMPS Eastpump(G-14A)

N/A N/A 1981, 2001 Surface all supports West pump (G-148)

N/A N/A 1991 Surface all supports REFUELING WATER PUMPS North pump (G-27N)

N/A N/A 1964, 2004 Surface all supports South pump (G-275)

N/A N/A 1994 Surface all supports m -


r

+

TABLE C-3.3 fcon'd) pig 2 2 cf 2 PUMP INTEGRALLY WELDED SUPPORTS APPR0X.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF

_. DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS SIS RECIRClijATION PUMPS East pump (G-45A)

N/A N/A 1981, 2001 Surface all supports West pump (G-CB)

N/A N/A 1991 Surface all supports l

l I

4

TABLE 3.4 PUMP SUPPORT COMPONENTS APPR0X.

APPR0X.

WELD LENGTil PRIMARY WELD TilICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNAT*0N (INCHES)

(INCHES)

DATES EXAliltlATI0ft REMARKS FEEDWATER PUMPS East pump (G-3A)

N/A N/A 1981, 2001 Visual all supports West pump (G-3B)

N/A N/A 1991 Visual all supports RESIDUAL HEAT REMOVAL PUMPS East pump (G-14A)

N/A N/A 1982, 2002 Visual all supports West pump (G-148)

N/A N/A 1992 Visual all supports REFUELING WATER PUMPS North pump (G-27N)

N/A N/A 1984, 2004 Visual all supports South pump (G-27S)

N/A N/A 1994 Visual all supports SIS RECIRCULATION PUMPS East pump (G-45A)

N/A N/A 1981, 2001 Visual all supports West pump (G-458)

N/A N/A 1991 Visual all supports

g TABLE C-4.2 Paga 1 of 3 VALVE PRESSURE RETAINING BOLTING APPROX.

APPR0X.

l WELD LENGTH PRIMARY WELD TilICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES

'EXAf1IllATION REMARKS SAFETY INJECTION VALVES HV 851 A 18 Studs and 1-6 N/A N/A 1978, 1998 Visual and either Notes 1 & 2 double nuts Surface or Volumetric (1-5/8" Dia.)

7-12 N/A N/A 1981, 2001 Visual and either Notes 1 & 2 Surface or Volumetric 13-18 N/A N/A 1985, 2005 Visual and either Notes 1 & 2 Surface ' Volumetric HV 852 A 18 Studs and 1-6 N/A N/A 1979, 2000 Visual and either Notes 1 & 2 double nuts Surface or Volumetric (1-5/8" Dia.)

7-12 N/A N/A 1982, 2002 Visual and either Notes 1 & 2 Surface or Volumetric 13-18 N/A N/A 1987, 2007 Visual and either Notes 1 & 2 Surface or Volumetric HV 851 B 18 Studs and 1-6 N/A N/A 1988 Visual and either Notes 1 & 2 double nuts Surface or Volumetric (1-5/8"Dia.)

7-12 N/A N/A 1991 Visual and either Notes 1 & 2 Surface or Volumetric 13-18 N/A N/A 1995 Visual and either Notes 1 & 2 Surface or Volumetric

r TABLE C-4.2 (con'd)

Pag 2 cf 3 VALVE PRESSURE RETAINING BOLTING 1

APPROX.

APPR0X.

WELD LENGTH PRIMARY WELD TilICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCllES)

(INCilES)

DATES EXAf11 NATION REMARKS HV 852 B 18 Studs and 1-6 N/A N/A 1989 Visual and either Notes 1 & 2 double nuts Surface or Volumetric (1-5/8" Dia.)

7-12 N/A N/A 1992 Visual and either Notes 1 & 2 Surface or Volumetric 13-18 N/A N/A 1997 Visual and either Notes 1 & 2 Surface or Volumetric CHECK VALVE 12" - 600 - 222 (EAST) 20 Studs and 1-7 N/A N/A 1978, 1998 Visual and either Notes 1 & 2 double nuts Surface or Volumetric (1-1/8" Dia.)

8-14 N/A N/A 1984, 2004 Visual and either Notes 1 & 2 Surface or Volumetric 15-20 N/A N/A 1987, 2007 Visual and either Notes 1 & 2 Surface or Volumetric CllECK VALVE 12" - 600 - 222 (WEST) 20 Studs and 1-7 N/A N/A 1988 Visual and either Notes 1 & 2 dauble nuts Surface or Volumetric (1-1/8" Dia.)

6-14 N/A N/A 1994 Visual and either Notes 1 & 2 Surface or Volumetic 15-20 N/A N/A 1997 Visual and either Notes 1 & 2 Surface or Volumetric MAIN STEAM ISOLATION VALVES _

24" - 600 - 27 BG N/A N/A 1978, 1998 Visual Notes 1 & 2 (East) - 1/3 of bolting 1981, 2001 inspected each inspection date 1985, 2005

TABLE C-4.2 (con'd) 3 VALVE PRESSURE RETAINING BOLTING APPRCX.

APPROX.

WELD LENGTH PRIMARY WELD THICKNESS OF WELD INSPECTION MODE OF DESCRIPTION DESIGNATION (INCHES)

(INCHES)

DATES EXAMINATION REMARKS 24" - 600 - 27 BG N/A N/A 1988 Visual Notes 1 & 2 (West) - 1/3 of 1992 belting inspected 1995 each inspection date NOTES Note 1:

Bolting may be examined either in place, under tension, when the connection is disassembled, or when the bolting is removed.

Note 2:

Nondestructive examination shall be performed on 10% of the bolting in each joint per ten year interval, but not less than two bolts or studs per joint. Visual examination shall include 100% of the bolting.

i-m m