ATTACHMENT 2 VERMONT YANKEE NUCLEAR POWER STATION OCRDR LABEL STANDARD - Revision 0 VERMONT YANKEE NUCLEAR POWER CORPORATION Approved
[
3 b
2-#'7d Project Managet v Date Approved
- '* W NUREG U/J/ ProgPaN Manager Date
/$s h 3 -/ /-86 Approved __ i Vice PresToent and(j M Date Manager of Operatto W 0604070109 060314 DR p
ADOCK 05000271 PDR
CONTROL ROOM LABELING
'$$bh[
g-GENERAL PHILOSOPHY 1.
New labels will have the fewest possible changes to the existing descriptor. Any changes will be made to either insure accuracy, or state the descriptor more clearly.
2.
All abbreviations and acronyms will conform to the current Vermont Yankee Nomenclature Standards. No engraver discretion is to be used in label abbreviations.
3.
All necessary information, currently on Dymo tape or handwritten on the panels, will be incorporated into the label information or the zone coding, at Vermont Yankee's discretion.
4 Hierarchical labels will be added, in conjunction with demarcations, for panel clarity.
5.
All label dimensions specified shall have a tolerance o f +.05".
6.
All new labels will follow human factors principles and anthropometric considerations.
r -
_7.-.
c CONTROL ROOM LABELING
%I
~.a+
GENERAt. SPECIFICATIONS MATE *.IAL Label material shall be 1/16" thick, 2 ply lamicold.
Surface ply will be white, subsurface ply will be black. All edges will have a 45 degree bevel.
COLOR All labels will be white with black characters, unless otherwise specified.
CHARACTERS Characters shall be engraved in Block Normal style (unless otherwise specified), at 135%
spacing, with the following stroke widths:
.012" for 3/32" Characters
.015" for 1/8" Characters
.020" for 1/4" Characters Character height is measured from center of stroke width.
Typically, the distance between lines of text is 1/2 of the character height.
The number
'2', in the case of 02 for oxygen or N2 for nitrogen, will be shown it a 25', reduction in size from the surrounding descriptor.
DIMENSIONS Margins will be 1/8", including the bevel, unless otherwise specified.
See typicals for specific label dimensions.
PLACEMENT Labels should be placed 1/8" from related device (s),
unless otherwise specified.
ADHESIVE Afix all labels to the panel or component with 3M Urethane adhesive foam tape no. 4052.
(Exception: TYPE 78)
6 s
l CONTROL ROOM LASEL TYPt t
~#
0! MEN 5!045 TYPICAL l
TYPE munggt (in taches)
Appt!CAf!04 1A 5/8 s 2 5/8 1 or 2 If ne descrf otor 18 3/4 s 2 5/8 3 If ne descriptor IC 5/8 a 2 1 or 2 itne descriptor ID 5/8 3
1 or 2 Ifne descriptor 2
3/4 s 2 5/8 2* sq. back plated devices, push buttons. key switches.
CR 120 settches. Fosboro rec.
3 3/4 s 2 1/4 Uppermost key settches on 4
back panels 4
1/2 : 1 5/8 GE.180 or Sigma lineer analog 10 no.
5 5/8 a 1 5/8 GC.180 or 5tgma itnear saalog descriptor 6
3/4 a 3 GL A618 or controller corbina tions 7A 3/4 s 5 1/4 secor1ers etthout all glass froats 78 1 s 5 5/8 8ec:rters eith all glass fronts 8
1a4 w jor System Identifiers a
9 1/2 m (t)
Ce-arcation !$entifiers 10 In'or*ation fags I
11 5/8 m (s)
Coacceent grouping 12 5/8 s 1 Core ccordinates 13 5/8 s 2 LP8M 8 sttfon 3
t l
14
$/8 s 2 5/8 3reater Cesignation 154 3/4 a 2 7/8 I L C plug.tn mod.10 no.
154 1/4 a 2 7/8
! L C plug.In mod. 3 Ifne gescriptor 16 1/4 a 1/2 Set Potets 17 1/2
$/8 A0G Instrueent Locators AM1UNCIAf0R windows 1 a 3 or 11/4 1 or 2 Ifne desertotor ANNUNCIATOR Hl[RARCHAL 1 a variable
! Ifne descriptor i
t i
I
DESCRIPTION TYPICAL FROM STEAM TYPE 1A M. ',.
LINE B c 4
. Panel Mounted
= 1 or 2 line descWpler o 5/8" x 2 5/8"
- 15 Characters maximum per line TYP! CAL APPLICATION (Actual Size)
TYPE 1A Labels are used when a 1 or 2 If ne descriptor is needed.
(e.g. mimic end points)
FORMAT One line Descriotor 1/8" lettering, centered.
15 characters max.
l l'
j Two line Descriptor_
1/8" margins 1/8" lettering, centered 1/16" space between lines VERMONT YANKEE l
15 characters max. per If ne l
LABEL STANDARDS 0'
TYPE 1A
- '.4 u mt
'td.
g y
4 A.S. Reeserte Professional Consultants
j
~
RHR A/C LOGIC i
DESCRIPTION LPCI/RECIRC VALVE RESET TYPE IB Panel Mounted 2 or 3 line descriptor 3/4" x 2-5/8" i
15 Characters maximum per line
)
l
\\
i 4 ;
s 1 j
TYPICAL APPLICATI0'4 (Actual Size)
- )
t TYPE IB Labels are used wnen a 2-5/3" label with a 2 or 3 line descriptor is needed. (e.g. certain key loct ji j
switches.)
il l
1 l
F0WAT 1
j I
I l
l I
i l
(
i l
l l
l i
l Three line Descriptor 1/8" marJ ns i
l 1/8" lettering, centered 1/16" space between lines l
15 characters 9a4 per line
[
i l
Two line Descrip*oz 1/8" side margins only 1/3" lettering, centered l
1/16" spacing between lines VER'40NT YANKEE 15 characters max per 1fne LABEL STANDARDS l
4 i
l TYPE 13 l
(
l 6A"M
.Cl/l$ 4, O.C. Meerts Profess cn31 Censuitar.ts l
ANNUNCIATOR DESCRIPit0N CRP 9-3 TYPE IC
- Panel mounted p !.
~
2 line Descriptom e.A.
5/8" x 2" l
- 12 Characters maximum per line I
TYPICAL, APPLICATION (Actual Size) l TYPE IC Labels are used when a 1 or 2 line descriptor is needed.
(e.g. Annunciator control label) n w.t!
I i
I l
l
,1 l
i Two Ifne Descefotor 1/8" margins 1/8" lettering, centered 1/16" space between lines 12 characters max per line f"'
VERMONT YANKEE LABEL STANDARDS
~~
"g TYPE IC
- <.y
- et
't-m.s, asserte Profesonal Consultants
""2'""
- "8 M'
s V
DEScarpTION TYPE 10 i
Panel Mounted SOURCE RANGE i
2 1!ne descrip % ~
MONITOR PERIOD 5/8 x3 18 Characters maximus per If ne '
TYPICAL, (Actual Size) j TYPE 10 Labels are used when a I
1 or 2 line descriptor is needed to replace an existing 3" label.
i i
i i
l l
t FI)4M A T t
f Two line Descriptor 1/8" margins 1/8" lettering, centered 1/16" space between Ifnes 18 characters max per line i
I *
VERMONT YANKEE LABEL STANDAR05
..:t TYPE 10
)
- n u
- art
't.
l a.a. asseres Professional censultants
' '8
r MscRtpff0N TYPICAL APPLICATION (actual size) l TYPE 2 TYPE 2 Labels are used in STEAM ISOLATION conjunction with the following HPCI-15
. Panel Mounted components:
ggp g g
.Descriptor
. Component 10 no.
2' sq. back-plated handles i
- 3 x
8*
l l
l FORMAT Line 1 l
Line 2 I
Line 3 I
I une 4 i
Line 1 1/8" Descriptor, centered 15 Characters max.
Line 2 1/8" Component 10 no., centeres 15 Characters max.
Line 3 3/32" Group no.
flush to left and bottom margins Line 4.
3/32" Power supply flush to right and bottom margins 1/8" Margins i
1/16* spacing between If nes 1 and 2 l'"'"'
VERMONT YANKEE LABEL STANDAR05 i
TYPE 2
- .s 3r
- art
'b j,
a.a. enesete professional Censultants
DESCRIPTION TYPE 3 START STOP
. Panel Mounted SUPPLY
. Switch Posttions FAN A
.Descriptor i
e3/4" x 2 1/4" i
TYPICAL APPLICATION (actual size)
TYPE 3 labels are used beneatn the uppermost key switches on i
back panels.
y l
F0RNAT l
Line 1 l
l Line 2 l
l Line 3 1
Line 4 Line 5 Line 1-3/32", position designator, 15 Characters max. for f10sh to left and. top margins ifnes 1, 2 1 3 combined.
Line 2-3/32", position designator, Line 2 may be left blank centered, flush to top margin, or may stand alone.
Line 3-3/32", position designator, flush to right and bottom margins I
Line 4-1/8' Oescriptor, centered 12 Characters max per line.
Line 5-1/8" Descriptor, centered 1/8' margins
" Lt:r MONT YANKEE 1/16" spacing between lines 4 and 5
- (l'A17fI;9 LA8EL STANDARDS TYPE 3
- wc. sv
- 4rr it.
A.S. 388859s Profesesonal Comultants
""0" 3 ' '
AfI t
{
PI 23-112 d
111 E
CESCRIPTION 150 TYPE 4
. Component Mounte&
. Component ID no.
jgg Power Supply I4U 1/2" x 1 5/8" typical Application (actual si:e)
TYPE 4 labels are mounted on all GC-180 and Sigma linear analog components.
FO MAT Line 1 I
Line 2 i
Line 1-1/8" Co ponent 10 no.,
centered, 10 char. nax.
Line 2-3/32" Power Supply centered.
1/16" spacing between lines 1 and 2 l " '"'
VERMONT YANKEE LABEL STANDARDS TYPE 4
- n it
- 4rt I.
gg j
a,3, esserts Profesponal Consultants
SENCH BOARD APPLICATION TYPE 4 t.abels
- Black, plexiglass wedge i
- y, I
surface l
riser I
t I
1/4" riser, 1
Surface dimensions are to match i
Type 4 label dimensions.
l (1/2" x 1 5/8")
label wedge n :a tent
~.
.Use double stick, foam tape to afix wedge to component and label to wedge, VER.u0NT YANrEE LABEL STAfl0A705
^
TYPE 4 - BENCH BOAR 0 APPLICA** ".
' ' " 4W.4
" zls flgcl A.S. Osems9e Professional Consultants
"" 3 d 3 "
i
DESC T 0-
.Descriptor
'M~
5/8" x 1 5/8*-
EXHAUST PRESSURE Typical Application (actual size) l TYPE 5 labels are Descriptors for GE-180 and Sigma linear analog components.
M FOR. MAT l
1 l
l Lines 1 and 2-1/8" Oescriptor, centered 10 Characters max. per line This label may have one line only, j
centered horizontally and vertically j
1/16" spacing between lines 1 and 2 i
i I
f VERMONT YANKEE LABEL STANDAR05 TYPE 5 1
M If 4ft
'(d-g m.m. asempts Profewonal Consultants 0'
P aEscalpit0M r
l gp TYPE 6 RHR HX-28 RHR HX-28 D1FF r-
- Panel Mounted E.
DIFF PRESSURE PRESS CONTROLLER E*M IU
- I N'N III Descriptor Group No.
i Power Supply 3/4" x 3a Typical Application TYPE 6 labels are used on all GE AS-18 or Controller combinations.
I t
k i
Line 1 l
Line 2 4
l Line 3 l
,J Line 4 1
i 1
j Line 1-1/8" Oescriptor, centered Line 2-1/8" Descriptor, centered 13 char. max per line Line 3-3/32" Component 10 no.,
l flush to left and bottom margins i
i j
l Line 4-3/32" Power Supply, i
flush to right and bottom margins 1/8" margins I
1/16" spacing between lines 1 and 2 i
l"'
VERMONT YANKEE f,
fi LABEL STANDARDS f
TYPE 6
- .2 3r
- 4ft
'O-gg
""C"
2
3.g. asempte Professonal Consultants
^
l l
f l
1 r
P l
OE5cRfpTf0N i
RHR PUMP FLOW FR10-143(Il TYPE 7A 8LK-LOOP B/D, RED-LOOP AC
.ComponentMounts4 l
.Descriptor v.
Component ID no.
Typical App 1feation (actual size)
-(Power Supply)
. Pen Information TYPE 7A labels are used on all recorders other 3/4" x 5 1/4" than GE clear-front style recorders.
t FORMAT I
Line 1 I
I Line 2 I
I Line 3 I
I Line 4 I
Line 1-1/8" Descriptor, flush to lef t margin Line 2-1/8" Component 10 no. (Power Supply),
j flush to right margin I
Line 3-1/8" left or top Pen Information, I
flush to left margin Line 4-1/3" right or bottom Pen Information,
- f. lush to right margin 1
32 Characters max. for lines 1/2 or 3/4 1/8" Margins.
3/32" spacing between lines 1/2 and 3/4 i
FM 3 PEN ASCW0ERS, another pen descrf otor my be added, g
centerse, hetuses Ifnet 3 and 4 Resulting muld be e 32 cheresser esatens for If nes 3, 4 and added descriptor coattned. Line 3 f t top pee informatton.
Added, centered descriptor 18 locand pen information Lfne 4 ts now thfrd pen infoneetton VERMONT YANKEE LABEL STANDARDS r
TYPE 7A
- .s s,
- arr
't.
....o n.,
- m
- .s
. _ _ co.,,,
f
.r--
.-,.n--..
~
'1 l
- 7 j
l UESC**
!~
TUR8INE VIBRATION VR 23 Ivl BLK-CH.1 OR 2 RED-UNUSED l
TYPE 78 i
l Component Mounth
.Descriptor l
Component ID no.
i
.(Power Supply)
+ Pen Informstion
- 1" x 5 5/8" j
Typical Application (actual' size) i' TYPE 78 labels are used on all j
GE clear-front style recorders.
I k
l FO R. MAT t
]
I Line 1 I
I Line 2 I
i I
Line 3 I
I Line A I
i i
Line 1-1/8" Descriptor, flush to left margin i
l Line 2-1/8" Component 10 no. (Power Supply).
l flush to right margin j
Line 3-1/8" left or top Pen Information, j
flush to lef t margin
,l l
Line 4-1/8" right or bottom Pen Information j
flush to right margin j
32 Characters max for lines 1/2 or 3/4 l
1/8" top and side margins (bottom of label at ti l
i De obscured when mounted) l 3/32" spacing between lines 1/2 and 3/4 i
rea 1 Pen accoaou.s. anotmer Den de e intor m y ee added.
l centered, bet e Itnes 3 ena 4 aesuittag ew14 ee a 1
32 cherecter mentam for Itnes 3, 4 and added descriptor coatined. Line 318 top pen infometton.
add.4, centere descriptor is i.cona p.n infor~iven Lf ne 4 ts now third pen Infometton VERMONT YANKEE 1 l LABEL STANDARDS j
i
"~'
TYPE 78 1
.eG H l4ft
'Id-i i
m.s. asserts Professonal Consultants l
{
i
HPCI DESC"
- ro" TYPE 8
-Or-
- 14 Characters maximum per Ifne Typical Application (actual size)
TYPE 8 labels are used as Major System Identi fiers FORMAT ONE LINE DESCRIPTOR 1/4 Characters, centered 14 Characters maximum TW LINE DESCRIPTOR 1/4 Characters, centered 1/8" Side margins i
3/16' Top and Botton margins 1/8' spacing between lines 14 Characters max. per line l
VERMONT YANKEE LABEL STANDARDS l
2;;'
TYPE 8 36 av
- arr
'U.
.... m.,,
- .r.
,__c,,,,,,,,,
t'
STEAM FLOW / FEED FLOW -
DESCRIPT!0M TYPE 9 l
.PanelMounted l l Q Q _1 s
. DemarcatiesP VI v
I Identifier 1/2" x (X) l Typical Application (actual size)
TYPE 9 labels are used in conjunction wf th brackets or outlines I
FORMAT
/
I
\\
}
/
\\
1/4" Descriptor 1/8" Margins (X) is determined by the descriptor length 5
l";'
VERMONT YANKEE 2'"'""
1.ABEL STANDARDS TYPE 9 uit
'l'-
- ,s 1,,
m.s. emesses Professonal consultants
m-nn,,,,,-----n-_,. _ _ -
,-,-,,a
---_-.,,,._,.-.-----,----,w--
OESCRIPTION TYPE 10
~
.,ane.
. Ya,f a.i.
.gt:i;::,sio,e CLEAN UP TEMPS
^
i.
2.
3.
4.
i 5.
6.
l Typical Application (actual size)
TYPE 10 labels are used when additional l
Information is required.
l (Example shown with 3/16" and 1/8" characters) l l
i FORMAT Height and Width of a TYPE 10 label are determined by the amount of information required.
Character sizes available: 3/32", 1/8", 3/16" and 1/4".
Specify:
1.
Exact information required.
2.
Character size (s), if known.
3.
Overall label dimensions, if known.
f "*
VERMONT YANKEE LABEL STANDARDS Type 10 NG If Art
'i' appe0vt0 B7 l Aft
- ~.
g ggg i
0 0
0 DESCRIPTION TYPE 11
. Panel Mount
)
A B
C CLEAN UP TEMI en De cr.
5/8" x (X)
Typical Application (Not to scale)
TYPE 11 labels are used for two or more like components, in a row, in the same system. (Selected use only) 4 i
FORMAT Z
I I
I 4
Line 1 @
B
\\
l Line 2 I
l l
l Line 1-1/8" Component Descriptor, designated 1A, IB, IC, etc.,
on component center-line Line 2-1/8" System Descriptor, centered on label 1/8" margins 3/32" spacing between lines 1 and 2
. Length to be determined by the number of components to be grouped times "Z".
3/32Hverticle line, at the top of label, is to be placed at the center-line between components in grouping l
. Existing TYPE 11 labels; Z=13/4" j'it!;7 VERMONT YANKEE LABEL STANDARDS TYPE 11 sc 2r
- art
't..
A.S. Meerte Profestonal Consultants
'l
DESCRIPTION TYPE 12 A4 Ul
.Displa@.
. Core 5/8" x TYP! CAL APPLICATION (Actual Size)
TYPE 12 Labels are Core coordinates.
FORMAT l
1/4" Numerals, centered.
3 Characters maximum.
m.t::
VERMONT YANKEE LABEL STANDARDS TYPE 12
- v. s,
- 4rt 30.
l
- m m.
_ c_
01-10 DESCRIPT!.
TYPE 1 l
.Displ 3
I
.LPRM TYPICAL APPLICATION (Actual Size) 5/8" x 2*
TYPE 13 Labels are LPRM Positions.
R FORMAT 1/4" Numerals, centered.
7 Characters maximum.
t
(
l
.c
>> u ;
VERMONT YANKEE 2' '2*"
LABEL STANDARDS TYPE 13
'D-
- w se j nrt,
=m
~
OESCRIPTION TYPE 14 F
\\
7 I
. Panel
. Breaker
~
a i
.5/8" x 2 l
TYPICAL APPLICATION (Actual Size)
TYPE 14 Labels are Breaker Designators.
l FORMAT I
l l
1/4" Characters 9 Character maxii.'.um VERMONT YANKEE 2' 5 "" "
LABEL STANDARDS TYPE 14
- x. sv
- art
'id-l u m ro ir
- art l
3 l
i I
4 DESCRIPTION l
TYPE ISA-g sluteAt @ ELEttnic g
j Panel l-Descri
~
Group Power Supply 3/4" x 2 7/8" RHR PRESSURE OM 10-13089 (D
l TYPICAL APPLICATION (Actual Size)
TYPE ISA Labels are used for ! & C plug in modules when an instrument I.O. number is needed.
FORMAT l
Line 1 l
Line 2 l
Line 3 l
l Line 4 l
Line 1-1/8' Descriptor, centered Line 2-1/8" Descriptor, centered 18 char. max per line Line 3-3/32" Component ID no.,
flush to left and bottom margins Line 4-3/32' Power Supply, flush to right and bottom margins 1/8" margins 1/16" spacing between lines 1 and 2 "0'5 ;
VERMONT YANKEE LABEL STANDARDS TYPE 15A
- v. se art
'i.
uneoves se art
- e.
g g,
(
V DESCRIPTION
..... AL g m._
,,, 1,
- Panel' s
3 line
- 3/4* x 2 7/
I
'd r.:E L _ _
i RHR PRESSURE INST TYPICAL APPLICATION (Actual Size)
TYPE ISB Labels are used for I & C plug in modules whei a 3 line descriptor is needed.
I i
FORMAT i
Three If ne Descriptor 1/8F margins 1/Ftetterie6;t, centered 1/1F space between lines 18 characters max per line ii i
340E!U VERMONT YANKEE l
- n:mn:,
LABEL STANDARDS
- t i
TYPE 158 j,
>o.
m, are p
unovra av arr v.
u esses.s Pm htants i-
L83 eisti sees DESCRIPTION I
TYPE 16 i
g
. Component I
N 1 line-n Itas 1/4" x 1/
gay itsi ortsatt l
i l
I SENERAL $ lLECTRIC l
l-
-j TYPICAL APPLICATION (Actual Size) l l
TYPE 16 Labels are Set Points.
l l
FORMAT t
3/32" Numerals, centered 4 Numerals Max.
I I
nu::
VERMONT YANKEE LABEL STANDARDS l
l TYPE 16
, _ _ c_,
lL
DESCRIPTOR Panel
.. 2 Line
..1/Z* x TYPICAL 4PPLICATION (Actual Size)
TYPE 17 Labels are A0G Instrument i
locator tags.
I i
FORMAT l
I I
l i
I I
i I
I l
l Line 1-Instrument no.
Line 2-Instrument no.
3/32" Lettering 3/32" Space between lines l
5 Characters max.,)er line.
g-
- nt VERMONT Yi.NKEE LABEL STANDARDS TYPE 17
.v. se arn unoneas urt
- a am mm 9
,e-v-y --
,-,--y-e99_m
-_---9y-pm
_w.%,.e,.-
eew- -
-,,,,e--4
,,wy
_.---,*v v----------v---+-'-~--w--
= '
vv
DESCRIPT10N l
"""c'a" ="^ac=
. One line 1" x Vari h,..
TYPICAL (Actual size for 1 row application)
ANNUNCIATOR HIERARCHAL Labels will be mounted on the uppermost section of the anr.'~ciator frame, centered over the apprcariate vertical row of windows.
FORMAT 1
l t
1" x (See table below) 1/4" BLOCK NORMAL lettering, centered.
12 Characters maximum for 1 row application i
I l
LABEL LENGTH for 31/4" windows:
for 3" windows:
1 row
-3 1/4" I row
-3"
(__,
2 rows -7 1/8" 2 rows -6 7/8" 3 rows -11" 3 rows -10 5/8" 4 rows -14 13/16" 4 rows -14 1/2" l
5 rows -18 9/16" 6 rows -22 7/16" a t:-
VERMONT YANKEE ANNUNCIATORS Hierarchal Labels
.m. _
m,j,,,
- m
- e.
(
0FF GAS RAD HI-HI oeScarattoa A
NCaron wrNo" TIMR STRT 1 or 211 1" x 3* or -
14*
(Format Ts
.F
- 16 to 18 Characters per line.
TYPICAL APPLICATION (Actual Size)
ANNUNCIATOR WINO 0W ENGRAVING FORMAT i
1 r
t l
1 1/4" BLOCK NORMAL Condensed Lettering 3/16" Bottom and Top Margins 1/8" Side Margins 1/8" Space between lines of text 16 - 18 Characters maximum per line (This label may have a one line i
descriptor, centered horizontally and vertically).
s m s::
VERMONT YANKEE ANNtlNCIATORS Window Engraving zos u urt
- E*-
l a.m.esseres Profesmons consstants
^
l w.- - - --.
Devices included in the REG. GUIDE 1.97 Type A Variable list will be marked with a 1/4" RED Circle (Pressure sensitive)
Recommended: Chroma Dots by Prestype #C07021-25 i
VERTICAL ANALOG INDICATORS Label TYPE 4 Lower right hand corner PI 23-112 (Il l
1 j
150 l
120 i
I RECORDERS j l Label TYPE 7A & 78 Top center I
i RHR PUMP FLOW FR10-143tIl l,
BLK-LOOP B/D RED-LOOP AC l
.I VERMONT YANKEE t
g l
- t
~i Color Identification
- 4 3r
- 4rt g
A.S. Esserte Professional Consultants
""C '!) "
- 27
I" i
THROTTLE HANDLE LABELING MATERIALS
- 1. Black Bumpers Round, sel f-adhesive
.37" dia. x.12" Hansond Manufacturing Co., Inc.
No. 1421 T2
- 2. Vinyl Lettering, sel f-adhesive, 1/4" White, Helvetica style E-Z Industries Inc.
No. 401W DIRECTIONS
- 1. Adhere bumper to component handle, centered over screw hole.
- 2. Adhere white letter "T",
centered on face of bumper.
1.
2.
g i
screw hole
(
)
i d
J f
I I
i a.: -
VERMONT YANVEE
- ::2 :..
LABEL STANDARDS I
7
" Throttle" Handles l
M 24 3' jgg y/g g
gress,anai censuitants p-
""=="
=
VY ABRkHVIATION S?ANDARD Pne 1 EQUIPMENT LAiEL NAME PREFEUNCE A 6 B 5 EV I AT I09 ACCELERATE ACCCL ArCCL ACCUMULATOR ACCUNULAIOR ACCUM ACTUATOR ACfUATOR
?,C T ADVANCED ADV ADV ADVANCED OFF GAS A0G AcG ADVANCED OFF GAS CLOSED COOLING WATER A0GCCW A0GCCW AFTERC00LER Aft CLR A E r c r,p AIR CIRCUIT BREAKER ACP ACI' AIR COMPRESSOR AtR ComPR A IF c rM p p AIR CONDITIONING AIR CONDIT10rvING A/C AIP' EJECTOR AE AE AIR EJECTOR OFF GAS AEOG AEOG AIR OPERATED VALVE ADV A0V ALTERNATE ALT ALT ALTERNATE ROD INSERTION ARI ARI ALTERNATING CURRENT AC A
AMPHERE AMP AMP ANALY~ER A N A L Y ?.; R ANAI.
AND Ab ri L
,>. J N U N ANNUN AREA RADIATION MONITOR ARn ARM ATMOSPH ER IC AT"'1 ATeos AUTOMATIC a ') (O A ?TO AUTOMATIC DEPRESSUPI~ AT!CN SiSTEM AE:
ADS AUXILIARY MA AU3 AVERAGE POWER R ANGE ~0N ITOP ASPn APGs BACKWASH e ; O. 6,d H n/L BATTERY
!A f T 6 AT
- BCARING B st r, it R G BELLOWS act r
BELL-BCTWEEN
' $' f W % -
r%'
i,L9CK
.: 0r rt L L B0ILER f< 0 -.-
BLR B0ILING 1ATER REACTOR
'J P t; '
BREAKER f
PW DUILDING
- n. r:S 9 L:4 BYPASS P--
aYP CABINET r x
!An CARRIER
- AFP[E9 C:. 'N CATHODE RAY TUBE 07T C '+ r CENTRIFUGE CENT C: NT CHANGER OR CHANGING C; Poi C H Nfi CHANNEL CHANrCL CH CHARGER OR CHARGING CHPG CHRf; C H E C'i C H 5? C K CHU C9EMICAL CHEM C b E ri CHLORINE C i.
C f.
C IR C'J IT CIPCull C'T CIRCUIT BREAKER Bn BUN C IRCUL AT ING CIPC C ipr CIRCULATING WATER CiSC W(R C i9C if-CIRCULATING WATER BOOSTER C IRC W1 R f uGSThi C V it C IPCUnFERENT I AL C [RCUM CIPDJM CLEAN RADWASTE CPW CFJ
s
.s VY ABBREV TATION STANDARD P m ;., 3 EQUIPMENT LABEL NAME PPEFEPENCE M EhEVIATTON CLOSED CLOSED CLSD COLLECTION OR COLLECTOR COLL COLL COMBINED INTERMEDIATE VALVE CIV CIV COMPARTMENT COMPT C0sPT COMPRESSED OR COMPRESSOR COMPR C o.9 P R COMPUTER CMPIR CMPic CONDENSATE OR CONDENSOR COND CC*lD CONDENSATE STORAGE TANK C3!
,:S r CONDUCTIVITY CONDUC CONDUC CONTAINMENT CfMT CTMT CONTAINMENI ATMOS?HERIC D ILUTION SYSTEM CAD C40 CONTINUOUS AIR MONITOP CAM CAn CONTROL CONTROL CTE;.
CONTROL ROD DRIVE CRD CPD CONTROL RUOM CTRL RM CTFL En CONTROL ROOM PANEL CRP CRP CONTROL SWITCH CTPL SW CIRL SW CONTROL VALVE CTFL VLV CV COOLER COOLER CL9 COOLING CLG CLG COOLING TOWEP FLG TJR CLG TWP CORE. SPRAY COPE SPPAY
~S COUPLING CCUP coup CURRENT CURPF"!
"URE DECONTAMINATION DECON DECC-DEMINER ALIZED WATER ST09 AliE T ANK DST OST DEMINERALIZER DRM M DCrIn DETECTOR DET DET DIAPHRAGM
'lfAPH D P AP '
DIESEL GENEPATOR DG O'
DIFFERENTIAL OR DIFFERENCE LIFF
- t r
DIFFERENTIAL PRES 3URE P
DIRECT CURRE:JT
- 't DC Dr.RTY RADWASTE Dc
'N DISCHARGE
- ! ! C r' DDt nISCONNECT DISC n
D IV IS ION DIV
.~ P !
DOWNCOMER D W h.~. rw 09 %
DOWNSCALE DWNSCI OWNGr!
DRAIN DRAIN O k t>
DRIVE DRIVE DR DRYWELL D910CLL DWL ECCENTRICITY ECC L:
ELECTRIC OR ELECfRICAL ELEC ELEC ELECTRONIC PRESSURE PEGULArJR EPP EPP ELEMENT CLEM EL'*
EMERGENCY EMERG
- M E P r, EMERGENCY CORE COOLING SYSTFM ECCS C TCS EMERGENCY SAFETY SYSTEM ES3 ESa ENCLOSUPE ENCL CNCL ENGINE UNGINE E N r.
EQUALIZER OR SOUILIZING EQUAL E0 0 r> L EQUIPMENT EOMT EOMT EQUIPMENT DRAIN TANK EOMT DRN fK E G M T l't
~
I 1
4 o
VY ABBRFVIATION STANDARD Pue ;
EQUIPMENT LABEL NAME PREFEk!"CE A8e SVIATIon EVAPORATOR EVAP EVAP EXCITER EXC EXC EXHAUST OR EXHAUJTER EXH EXH EXPANSION EXP E(P EXTRACTION SXT EXT FAST FAST Est FEEDER FDP FDR FEEDWATER EEEDWA1ER FW FIELD FIELD FLD FILTER FILT FIL!
FILTER DEMINERALIZER DEMIN DEMIu FIRST IST 1;T FLOOR FLOOR PLR FLOOR DRAIN COLLECTOR TANK FLR DRN TK FLP. ONN n FLOW F L O'4 r.]
FORWARD FWD FuD FOURTH 4TH 4TH FUEL POOL FUEL PUUL FUEL PCOI GENERATOR G.S N
.G EN GLAND S t. AN D G I, GOVERNOR GOV GOV GROUND GND GND GROUP GPOUP G T. T HEAD
- CnD H
HEADER HDE HDP HEAT 1 EAT HT HEAT EXCHANGER M *.
Et HEAT.VENTILAT[GN. i A IR CO*'!!IT I0tJ ING J-Ar
,jw HEATER ti t o HEATING ri ? '
., T r HERTZ it?
HIGH Hi
-t r HIGH PRESSURE HE b-H IGH PRESSURE COOLANT INJEC T ION
-PCI H^ri HOOD F
+!o o HOTWELL
-oU W E L H U T iJ f.
HUMIDITY Hun
.e HYDRAULIC Hr0 Hr9 HYDRAULIC CONTROL UNIT HCU
-t C U HYDROGEN l13 H1 HYDROGEN ANALYZER H 2 A N A '.
H ? iim.t.
INBOARD INBD INF0 INCOMPLETE It4 CC M t tsC OM INDICAIION OR INDICATOR IND INir INFO RM AT ION INFO T i> F 0 INJECTION INJ
[N I INOPERABLE INOP IN0F INSTRUMENT INST
- N S
INTERCEPT VALVE IV IV INTERCONNECTED
'NTERCONN I N T k. F ' 7 "
INTERLOCK INTLV TNTil INTERMEDIATE RANGE MONITOR IRM 1RF INTERMEDIATE STOP VALVE 19V ISV INVERTER INVEPT INVCC' 9
V1 ABBREVIATION STANDARD Ptw 4 l
I' EQUIPMENT LAML NAME PREFERENCE A889EVIAT ON ISOLATE.OR ISOLATION ISOL ISOL JET PUMP JET PunP JP KILOVAR KVAR KVA9 KILOVOLT KV KV KILOWATT KW gy LEAKAGE OR LEAKING LMG LKG LEVEL LEVEL
-LVt LINE L IN E LN LIQUID LIO LIG I.0 CAL POWER RANGE MONITOR LPRM f.PFn
[
LOCKOUT LVOUT LKOUT LOSS OF COOLANT ACCIDENI LOCA LOCA i
LOW LO Lo LOW PRESSURE LP LP l
LOW PRESSURE COOLANT INJECTION L3CI LPCI LUBE OIL LUBE UIL L.O.
l LUBE OIL CONDITIONER ROUSER BUWSER MACHINE MACH MACH MAIN STEAM ISOLATION VALVE s IV MSIV MAIN STEAM LINE MN 9 fM LN MN STM LN l
MAKE-UP MAKE-US et / U M AKEUP DEMINER AL I;:ER MUD Mt!D nALFUNCTION nALF nALP l
MANUAL MAN r? Are MANUAL PRESSURE EEGULATCR n !' ?
nPh l
H AX IMUM
- av Mut l
MAXIMUM CREDIBLE ACCIDENT
-LA nCsi M EC H AN IC A L nEC-H::b l
MET l-M IN IMUM
-N MIN j
metSTURE SEPARATOR el SED M*. T S E' MONITOR n0N no" MOTOR
- JT'E n!!?
MOTOR CONTROL CENTER m:C MCC MOTOR OPERATED DISCCNNECT suTTCH NCDS n 0 F, l
MOTOR-GENERATOR N'
MG NnRROW RANGE a r<
Np NEUTRAL NFUf NCUT N ITROGEN N:1 N2 NON-REGENERATIVE HEAT EXCHANGER NUN nEG Erl HV NON P E G 6t>
s NORMAL N0??AL tiO R d NORTH NU9iH N
NORTHWEST NW NW OFF GAS OFF GAS OG j
OIL CIRCUII BkEAKER UCB OCD l
OPEN OPKN OPh l
' OPENING JACK C P E N Irlli JACK U P "'i J AO-l OSCILLOSCOPE OSCIL UicIL OUT OF CUMMISSION 0 0 r.
00C O!:TBOARD OUTBD OU"En OVERCURRENT OVCURR OVCtG ?
l OVERLOAD (MOTOR OVERLOAD)
OVLD OVLD I
OVERRIDE OVRD OVRO OVERSPEED OVSPD O '.' 6 P D I
L
VY ABBREVIATION STANDARD Fpe S
EQUIPMENT LAGEL NAME PREEEkFNCE A& nFVtarIO.
OXYGEN OC 02 OXYGEN ANALYZER 03 ANAT 02 aNAr PACKING PMG PkG PANEL PNL P 9 f.
PARTICULATE PART par PENETRATION PEN PEN POINT PO IN T e?
POSITION POS PO%
POTENTIAL TRANSFORMEP POT XfMW POT ("7P POWER P9WER PWP POWER CIRCUIT BREAKER PCB PCD
' POWER OF HYDRONIUM ION PH rm PREHEATER PRE HTR F' R E e l F PRESSURE PRESS
??Esq PRESSURE CONTROL VALVE PCV HV PRIMARY PRI To
' PRIMARY CONTAINMENT PR I CTMf PPE CTor PRIMARY CONTAINMENT ISOLATION S Y S T Ett PC IS 5 7. ! R PROCESS PROCESS PROC PUMP PudP PunP RADIATION OR RADI0 ACTIVE RAD RAD RADIOACTIVE WASTE RADWAST6 R /!s REACTOR PX 9v REACTOR BUILDING Pt 51 yi Fi P E ACTOR BUI'.D ING CL'] SED r;0L ING JafgR PBr '.
R 'r'J REACTOR BUILDING VENTILAT 0N FPV
- 60 REACTOR CORE ISOLATION COOLfNG PC IC R~~
REACTOR PPESSURE VESSEL 2PV R t" -
REACTOR PROTECTION SYSTEn OM P4 REACTOR WATER CLEAN-UP SYSTEN P - C L:
4DC GECIRC PUMP ~R:P PPT 9?r RECIRCULAtIGN SYSTEM w.;w:
ro r > c RECOMBINER 98 Cot -
"U'h RECORDER
- DP REDUCER PLoc-REFUFL O E r u C '.
E'E REG EN ER AT IVE FrrEJ 9 l REGULATOR OR REGULATING REG L " '.
RELATIVE FdL au RELIEF VALVE RU I '.
RESIDUAL HEAT REMOVAL SEPV TCE WATET-FHFSU u.d N RESIDUAL HEAT REMOVAL SfSTEM FHR R"R RETURN REfuSN f< D REVERSE REV REV REVERSE CURRENT VALV3 N C V '. V 3C "
REVOLUTIONS PER MINUTE RPn (Pd ROD BLOCK MON! TOR RBM la ROD POSITION INDICATION SYSTEit FP13 201-ROD WORTH MINIMIZER RUM WM ROOM 200M Ut SAFETY VALVE SV S '>
SAMPLE 5 AMPLE 1aMr SATURATED SAT 1AT SCOOP SCOOP SCT l
s VY ABBREVIATION STANIARD pige g EQUIPMENT LABEL NAME PREFERENCE A CBF EV I AT ICN SCRAM DISCHARGE VOLUME SDV sDV SCREEN SCREEN SCRM SEAL SEAL 3L SECOND 2ND 2ND SECONDARY SEC SEC SECONDARY CONTAINMENT SEC CTMI SEC C 'M T SECTION SECT SECT SELECTOR SEL 1 E t.
SEPARATOR SEP EEP SEQUENCE SEO SEO SERVICE SEPV SERU SERVICE WATER SERV WTR SERV urP SHUT DOWN S/D S/D SIGNAL SIGNAL S!G SOURCE RANGE MONITOR SRM SRM SOUTH S00fH S
SPEED DEMAND SPEED DEM SPEED den SQUIB SQUIB SGB-STAGE ETAGE STG STANDBY "f0B(
STDDY STANDBY GAS TREATMENT ShG1 SBGr STANDBY LIQUID CUNTRUL SLC SLC SIARI UP S/U 9/u ST AT ION c 'i A
'iTA STEAN
'!Ean GTM STEAM JET AIR EJECTOP SJA:
S.i m STEAM PACKING EXAUSTER iTM P"G EXH S14 P ': G E s :.
STORAGE iTOP GTOP STRAINER
' T EN STro SUCTION S UC.' (O r, SHCT SUPERVISOR t: $ 9 S U F '/
SURGE TANK
- _' H E CA +
- PG SWITCH SJ
- c. W SW ITCHGEAR SF4 SunP SYNCHROSCOPE S:n-SYSTEM S ~t C *. 3 M
TANK TANL TV TEMPERATURE TEMP TEnF TEMPERATURE CONTROL VALVE TCV TCV THIRD 3RD 1RD THROTTLE THFCTTLE THROT TORUS
!ORUS 70DUS TOWER TWR TU?
TRANSEER XFEF XPER TRANSFORMER XFMR
/EMR TRANSMITTER AMfR C:TF TRA' JELLING TRVL TRVL TR AV ERS ING IN-CORL' PROBC T IP fii TREATMENT TRTMNT TkTMNT TROUBLE iROUBLC r !< s t TUNNEL TUNNEL TUNT.
TURBINE fUNB THRD TURBINE BUILDING TURB DLDO TP TURBINE BUILDING CLOSED CUULING WATER fBCCW TBCCW 1
....- ~
VY ABBkEVIATION STANDARD P rae /
EGUtPMENT
(. A P E L NAME PREFEPE.NCE A6BR6VIAT: n TURBINE BYPASS VALVE BYP VLV BYP VLV TURPINE STOP VALVE TURB STOP Vr.V TSV i
TURBINE SUPERVISORY INSTRUMENT PANEL ISIP 79 fP TURBINE-GENERATOR TURB GEN TURB GEh TURNING GEAR TURN GEAR TURN GCAP UNINTERUPTIBLE POWER SUPPLi VPS UP5 VACUUM VAC VAC VALVE 9LV VLV VAPOR OR VAPORIZOR VAP VAP VENTILATION J C.N T VEN' VESSEL VES VES VIBRATION VIBR V IER VIBRATION 1 LOGCE PARTS MUNIfUR V4LP vsto VOLUME VOLUME VOL WASTE COLLECTOR TANK WCf WC' WASTE SAMPLE TANK WST tJ S (
WATER WATER WTR l
WIDE RANGE WR WR WITHDRAW OR WITHDRAWAL WTHDRW WTHDRW YARD (APD rD 1
i i
6 l
1 l
r f
4
,.r.
,,.-,-n,,,-.,,-...,.
.,-,-e,..-,-.,,,,
(.
t 4
li e
t t
i i
t COLO4 STANDAR0 i
}
4 4
A f
t t
,-,-.-,n,
,,,n.
- -, _,,,-, - -,,,e
.n,..,-..,--,
, -.e-,,,_-ay_.,-_
,,u.,.-nw,-..,y_,w,,-s,,,n-,.-,,
--,,-y,,-n-w
[~
L y
- -. ~
.n
- - - - -... - - - -., ~ --,.
~
I 1
l l
e i
?
i 4
t.
t 9
i 6
i I
I i
e w w W
w w w w
w w w
O O O O
O O
O O
O O
w w
w m
w n
w w
w a
3 3
3 3
3 3
3 3
3 3
W 9
S S
S S
S S
'8 3
S W3 4
9 9
9 0
4 9
w e O
KO WW m
m a
w w
w m
m m
m W
W4 Jwe E>
4 34 l
{
I l
2 I
1 I
E!
we w w ww w w w w w
W w
w ww we w wwww
.w
>J 09 O
O 09 O
O O
O O
O O
O 00 00 O
0000 O
es ww w
w ww w
w w
w
=
m w
w ww wm w
wwww w
44 33 3
3 33 3
3 3
3 3
3 3
3 33 33 3
7333 3
E 3m S S S
S S S S
S S
S W
5 0
0 0 3 S S S
S S S S S
O NN N
N NN N
N N
N N
9 9
9 de me 9
9999 4
JW bw I
nm m
n mm m
m m
n
- n m
a mm mm m
mmmm m
E WM t
CE i
O 9
5 ed 4
EJ O
4 8
w 4
E e
>W W
d W
Om w
n n
3 3
M W
W A
O O
e w
3 3
1 W
W de d
O O
Q W
W ww 5
W 2
4 4
wE N
W W
W Jw O
4 4
4 m
w kJ J
2 m
b O
O
- O 3
Q w
w 4A W
w w
w O
w E
EW W
W 3
h W
n W
e 3
3d we W
~
w J
n e
E 3
w A
N&
=
23 3 m ES w
^
3
~2 En J
EXER J
=>
E
>w J
ww W
W w
O ww ww W
>wme w
de w
ww G
w we Q
J W
De w3 www&
2 E
25 W
35 4
m -
JW ad e
35 3 4
W e M
W Q
n W
J 3
ed S
k J
J WW e w
w W
O w
w 3
O E
4 2
e w
W 20 JE3 e
kw S
km W
W B
> c O
se
> e E
WWWW J
&>O W
M S w
W MS J
O w
O 3
d W
E
>E
=>
w 4 24h O
44J 3
Em 3
=
Ew w
D E
W 3
O J
wm TW dwJE E
Jh6 4
2h e
4 Eh o9 w
n W
e W
W 4
Eh at e
et50 3
ww w w ww w
w m
w w
w w
w ww ww N
wwwW 2
wOh N
N O
E40 NF W
~
N@
m m
S N
4 e
Nm OFOR W
>w 2
ed N
N Om 4
O d
f f
4 e
Ne ON me=W 2
O NN N
N NN N
N J
N N
N N
N NN NN J
NNN4 E
- WG S
E w
OOw S
O O
d wr>
w JJ J
J JJ J
J J
J J
J J
JJ JJ JJJS E
OwW 4
b 4
4 4
&&&O mew OO O
O OO O
O M
O O
O Q
O 00 00 W
000 2
D E
D D
D z
a w
mm
> >>W uO cow 44 4
4 44 4
4 4
4 4
4 4
4 4 44
- 4444 W
WMO WW G
W WW W
M i
W W
W W
W WW S4 9
WWWWE JW 4
J 4
4 w
W 44 44 w444w wM nw W
m E
E EE wwI l l I
6 8 8
8 w
1 8
9 0
0 I l i l 2
a l 8 8 4w MMM E
F w
E WE
&E WJ EE E
E EE w
e J
J P
AW E m 4
3 4
4 E =>
2 WM RE A&O 44 4
4 de A
O J
J W
W 44 w
o AO4 EW WWE 64 3
> w 4
4 J
w w
F4 O
w I
E Om M
M 33 3
3 33 O
W W
W W
4 W
W 23 W
> =>
04 we OO O
O DO J
=
w u > >
eB C0 3
4 erO
>E WNO JJ J
J JJ 6
2 5
5 m
W W
60 JJ w
WJ>
3 mm 66 6
6%
O J
W w
w 3d sh GEOw EO On E
=
W W
J J
Oh dw
% l Mk 3
O EO E
EQ w > w w
w W
w w
a E
2 wewJ MWw 4m 4
w Sw 4
J w
w 60 4
e EXh8 wW wD m3 W
W e3 H
J 4
W W
J W
J m
WW E
e3w w
>M wd4 kJ d
>J 3
A w
4 g
>4 a
W&
M W
X D
D p
D WJ W@
w 4 J JM RW edd W
W w
W W
D Q6 4
PwEwo WE ZE2 ww w
WW 3
m O
4 e
e eW e3 w
3dw UW W
W wm W
W 3
A W
4 5
@J 4 4 2
&he>J W J O
E WW 3
w O
+ =
N m
e 00 99 O
EwmWJ JJ EE W
W WW W
W W
9 m
N d
44 MW W
WmdO4 44 W
n
- n n
n n
n n
n n
n
~
O m
M n
f M
4 W
O m
N M
d 4
h 2
m m
o m
H m
a
VERMONT YANKEE SWITCH HANDLE COLOR AND LOCATION INDEX IHE FOLLOWING SWITCH HANDLES WILL BE FEDERAL STD. 595-A 27800 (WHITE) 1)
CRP 9-3 HPCI STEAM SUPPLY VALVE V-23-14 23A-S1 2)
CRP 9-3 HPCI STEAM ISOL VALVE V-23-15 23A-S2 3)
CRP 9-3 HPCI STEAM ISUL VALVE V-23-16 23A-S3 4)
CRP 9-3 MAIN STEAM ISOL VALVF V-2-80A 16A-SIA 5)
CRd 9-3 MAIN STEAM ISOL VALVE V-2-80B 16A-SIB 6)
CRP 9-3 MAIN STEAM ISOL VALVE V-2-80C 16A-SIC 7)
CRP 9-3 MAIN STEAN ISOL VALVE V-2-80D 16A-51D 8)
CRP 9-3 MAIN STEAM ISOL VALVE V-2-86A 16A-52A 9)
CRP 9-3 MAIN STEAM ISQL VALVE V-2-86B 16A-S2B 10)
CRP 9-3 MAIN STEAM ISOL VALVE V-2-86C 16A-S2C 11)
CRP 9-3 MAIN STEAM ISOL VALVE V-2-86D 16A-S2D 12)
CRP 9-4 RCIC STEAM SUPPLY VALUE V-13-131 13A-S2 13)
CRP 9-4 RCIC STEAM ISUL VALVE V-13-15 13A-St 14)
CRP 9-4 RCIC STEAM ISOL VALVE V-13-16 13A-53 15)
CRP 9-7 STEAM SEAL REG FEED VALVE SW-19 16)
CRP 9-7 STEAM SEAL REG BYPS VALVE SW-20 17)
CRP 9-7 STEAM SEAL REG UNLOAD VALVE SW-21 THE FOLLOWING SWITCH HANDLES WILL BE FEDERAL STANDARD 595-A 34108 (GREEN) 1)
CRP 9-3 HPCI PUMP SUCTION VALVE V-23-58.
23A-S14 2)
CRP 9-3 HPCI PUMP SUCTION VALVE V-23-57 23A-S13 3)
CRP 9-3 HPCI PUMP SUCTION VALVE V-23-17 23A-S4 4)
CRP 9-3 HPCI MIN FLOW BYPASS V-23-25 23A-S10 5)
CRP 9-3 HPCI PUMP DISCH VALVE V-23-20 23A-57 6)
CRP 9-3 HPCI TEST BYPASS VALVE V-23-21 23A-58 7)
CRP 9-3 HPCI REDUNDANT SHU f 0FF V-23-24 23A-S9 8)
CRP 9-3 HPCI PUMP DISCHARGE VALVE V-23-19 23A-56 9)
CRP 9-3 STEAM LINE DRA IN VALVE V-2-74 2E-SIA 10)
CRP 9-3 STEAM LINE DkAIN VALVE V-2-77 2E-$11t 11)
CRP 9-3 STEAM LINE DRAIN VALVE V-2-/8 2E-SIC 12)
CRP 9-3 SIEAM LINE DkAIN VALVE V-2-79 2 E-51 tl 13)
CRP 9-4 RCIC PUMP SUCTION VALVE V-13-18 13A-S4 14)
CRP 9-4 RCIC PUMP SUCTION VALVE V-t3-39 13A-So 15)
CRP 9-4 RCIC PUMP SUCTION VALVE V-lJ-41 13A-S10 16)
CRP 9-4 RCIC MIN ELOW BYP VALUE V-13-27 11A-S21 17)
CRP 9-4 RCIC CLG WATER VALVE V - 1 3 - 1.3 ?
IJA-Su 18)
CRP 9-4 RCIC PUMP DISCHARGE VALVE V-13-20 13A-SG 19)
CRP 9-4 RCIC TEST 9YPASS VALVE V-13-JO 13A-S7 20)
CRP 9-4 RCIC PUMP DISCHARGE VALVE V-13-21 13A-SS THE FOLLOWING SWITCH HANDLES WILL BE PAINTED A SHADE OF BLUE THAT MATCHES, AS NEARLY AS POSSIBLE, GRAV0 PLY 228 00EBEC BLUE.
1)
CRP 9-3 CS PUMP BYPASS VALVE V-14-5B 14A-S1B 2)
CRP 9-3 CS TEST VALVE V-14-26B 14A-S4I4 3)
CRP 9-3 CS DISCHARGE VALVE V-14-11B 14A-S2D 4)
CRP 9-3 CS DISCHARGE VALVE V-14-128 14A-S11t 5)
CRP 9-3 CS PUMP BYPAGS VALVE V-14-5A 14A-S3A 6)
CRP 9-3 CS TEST VALVE V-14-26A 14A-S4A 7)
CRP 9-3 CS DISCHARGE VALVE V-11-11A 14A-S2A 8)
CRP 9-3 CS DISCHARGE VALVE V-14-12A 14A-SIA
THE FOLLOWING SWITCH HANDLES WILL BE FEDERAL S f D. 595-A 26373 (BLUE) 1)
CRP 9-3 RHR PUMP BD MIN FLOW VLV V-10-16B 10A-S28B 2)
CRP 9-3 RHR RECIRC LOUP INBD ISOL VLV V-10-25B 10A-S8B 3)
CRP 9-3 RHR PUMP SUCTION VALVE V-10-15D 10A-S6D 4)
CRP 9-3 RHR PUMP SUCTION VALVE V-10-158 10A-SGB 5)
CRP 9-3 RHR DkYWELL SPRAY B ISOL VLV V-10-31B 10A-S118 6)
CRP 9-3 RHR CONT TEST VALVE V-10-34B 10A-S12B 7)
CRP 9-3 RHR RECIRC LOOP OUTBD ISOL V-10-27B 10A-S10B 8)
CRP 9-3 RHR HEAD SPRAY ISUL VALVE V-10-32 16A-S11 9)
CRP 9-3 RHR DkYWELL SPRAY B ISOL VLV V-10-2GB 10A-S98 10)
CRP 9-3 RHR SPRAY T DISCHARGE VALVC V-10-38B 10A-S13B 11)
CRP 9-3 RHR SPRAY T DISCHARGE VALVE V-10-39B 10A-S14B 12)
CRP 9-3 RHR HX BYPASS VALVE V-10-65B 10A-S16B 13)
CRP 9-3 RHR HEAD SPRAY ISOL VALVE V-10-33 16A-S12 14)
CRP 9-3 RHR ISOLATION VALVE V-10-17 16A-S10 15)
CRP 9-3 RHR ISOLATION VALVE V-10-18 16A-S9 16)
CRP 9-3 RHR RECIRC LOOP INBD ISUL VLV V-10-25A 10A-S8A 17)
CRP 9-3 RHR PUMP SUCTION VALVE V-10-15A 10A-SGA 18)
CRP 9-3 RHR PUMP SUCTION VALVE V-10-15C 10A-SGC 19)
CRP 9-3 RHR RECIRC LOOP OTBD ISOL VLV V-10-27A 10A-S10A 20)
CRP 9-3 RHR CONT TEST VALVC V-10-34A 10A-S12A 21)
CRP 9-3 RHR DRYWELL SPRAY A ISOL VLV V-10-31A 10A-S11A 22)
CRP 9-3 RHR PUMP AC MIN ELOW VALVE V-10-16A 10A-S28A 23)
CRP 9-3 kHR HX BYPASS VALVE V-10-6bA 10A-S16A 24)
CRP 9-3 RHR CORC SPRAY TEST DISCH VLV V-10-39A 10A-S14A 25)
CRP 9-3 RHR SPRAY TEST DISCH VLV V-10-38A 10A-S13A 26)
CRP 9-3 RHR DRYWELL SPRAY A ISOL VLV V-10-26A 10A-S9A 27)
CRP 9-3 RHR TO RADWASTE VALVE V-10-57 16A-S14 28)
CRP 9-3 RHR TO RADWASTE VALVE V-10-66 16A-S13 THE FOLLOWING SWITCH HANDLES WILL BE FEDERAL STD. 595-A 26373 (GREY) 1)
CRP 9-4 RWCU RX OUTLET VALVE V-12-15 16A-S15 2)
CRP 9-4 RWCU INLET VALVE V-12-18 16A-516 3)
CRP 9-4 RWCU DRN TO MAIN CONDESER VLV V-12-56 12A-S2 4)
CRP 9-4 RWCU DRN TO RADWASTE VLV V-12-57 12A-S3 5)
CRP 9-4
.TJCU CLEANUP RX REfURN VLV V-12-68 16A-S17 6)
CRP 9-4 RWCU CLEANUP BYPASS VLV V-12-74 12A-S4 7)
CRP 9-5 RWCU DRN ORIFICE ISOL VALVC V-12-53 12A-S1 THE FOLLOWING SWITCH HANDLES WILL BE FEDERAL STD. 595-A 33690 (IVORY) 1)
CRP 9-4 RECIRC SAMPLE LINE [ SOL VLV V-2-39 16A-S7 2)
CRP 9-4 RECIRC SAMPLE LINE ISOL VLV V-2-40 16A-SO THE FOLLOWING SWITCH HANDLES WILL BE PAINTED A SHADE OF PURPLE fHAT MATCHES AS NEARLY AS POSSIBLE, GRAV0 PLY 231.
1)
CRP 9-6 COND A HOTWELL OUTLET SW-42 2)
CRP 9-6 COND A HOTWELL O'TLET SU-43 J
3)
CRP 9-6 COND B HOTWELL OUTLET SW-44 4)
CRP 9-6 COND B HOTWELL OUTLET SW-45 5)
CRP 9-6 LP HTR TkAIN A INLET SW-46 6)
CRP 9-6 LP HTR TRAIN A OUTLET SW-48 7)
CRP 9-6 LP HIR TRAIN B INLET SW-47 G)
CRP 9-6 LP HTR TRAIN B OUTLET SW-49 9)
CRP 9-6 LP HTR TRAIN BYPASS SW-50 10)
CRP 9-6 RF PUMP A D ISC H ARGE SW-56 11)
CRP 9-6 RF PUMP B DISCHARGE SW-57 12)
CRP 9-6 RF PUMP C DISCHARGE SW-58 13)
CRP 9-6 FW REG VLV A INLET SW-13 14)
CRP 9-6 FW AUX REG VLV INLET SW-14 15)
CRP 9-6 FW REG VLV B INLET SW-15 16)
CRP 9-6 HP HIR TRAIN A INLET SW-51 17)
CRP 9-6 HP HIR TRAIN B INLET SW-52 18)
CRP 9-6 HP HTR TRAIN A OUTLET SW-53
19)
CRP 9-6 HP HTR TRAIN B OUTLEI 3y_54 20)
CRP 9-6 HP HTR TRAIN BYPASS Su-55 21)
CRP 9-6 FW RECIRC VLV V-63-22A SW-82 22)
CRP 9-6 FW RECIRC VLV V-63-22B SW-83 THE FOLLOWING SWITCH HANDLES WILL BE FEDERAL STD. 595-A 20062 (DARK BROWN) 1)
CRP 9-7 BREAKER IT SW-28 2)
CRP 9-7 BREAKER 81-1T SW-29 3)
CRP 9-7 DISCONNECT T-1 Su-30 4)
CRP 9-8 DISCONNECT 340-3 SW-120 5)
CRP 9-8 BREAKER 79-40 SW-121 6)
CRP 9-8 BREAKER 379 SW-32 7)
CRP 9-8 BREAKER 381 SW-33 8)
CRP 9-8 DISCONNECT 379-3 SW-37 9)
CRP 9-8 DISCONNCCT 381-3 SW-38 10)
CRP 9-8 DISCONNECT T-4 SW-40 THE FOLLOWING SWITCH HANDLES WILL BE FEDERAL S fD. 595-A 30108 (BROWN) 1)
CRP 9-8 BkEARER K-1 SU-34 2)
CRP 9-8 BREAKER K-40 SW-35 3)
CRP 9-8 BREAKER K-186 SW-36 4)
CRP 9-8 DISCONNECT T-3 SW-39 THE FOLLOWING SWITCH HANDLES WILL BE FEDERAL STD. 595-A 30450 (C0C0A P90WN) 1)
CRP 9-8 ACB-3V4 SW-22 2)
CRP 9-8 ACB-3V SW-7 3)
CRP 9-8 ACB-4V SW-8 4)
CRP 9-8 GENERATOR BREAKER SW-9 5)
CRP 9-8 GENERATOR BREAKER SW-10 6)
CRP 9-8 BKR NO. 38 Su-13 7)
CRP 9-8 BKR NO. 49 SW-14 8)
CRP 9-8 BKR NO. 3Il SW-1 9)
CRP 9-8 BKR NO. 4T2 SW-6 10)
CRP 9-8 BKR NO. 53 SW-23 11)
CRP 9-8 BKR NO. 13 SW-2 12)
CRP 9-8 BKR NO. 23 SW-3 13)
CRP 9-8 BKR NO. 210 SW-94 14)
CRP 9-8 BKR NO. 16 SW-11 15)
CRP 9-8 BKR NO. 27 SW-12 16)
CRP 9-8 BKR NO. 12 SW-4 17)
CRP 9-8 BKR NO. 22 GW-S 18)
CRP 9-8 BKk NO. 111 SW-112 THE FOLLOWING SWITCH HANDLES WILL HC FEDEPAL C fD. 595-A 11769 (ALMOND) 1)
CRP 9-8 BKR NO. 88 SW-17 2)
CRP 9-8 BKR NO. 99 Su-18 3)
CRP 9-8 BKR NO. 8T9 SW-20 4)
CAP 9-8 BKR NO. 9T8 SW-21 5)
CRP 9-8 BKR NO. 1010 SW-95 6)
CRP 9-8 BKR NO. 66 SW-15 7)
CRP 9-8 BKR NO. 77 SW-16 8)
CRP 9-8 BKR NO. 6T7 SW-19 9)
CRP 9-8 BKR NO. 1111 SW-113 THE FOLLOWING SWITCH HANDLES WILL BE FEDERAL STD. 595-A 23655 (YELLOW) 1)
CRP 9-3 RHRSW PUMP A P-8-1A 10A-S20A 3)
CRP 9-3 RHRSW PUMP B P-8-1B 10A-S20B 3)
CRP 9-3 RHRSW PUMP C P-8-1C 10A-S20C
4)
CRP 9-3 RHR$W PUMP D P-8-ID 10A-S200 5)
CRP 9-3 RHR PUMP A P-10-1A 10A-S24 6)
CRP 9-3 RHR PUMP B P-10-18 10A-S2B 7)
CRP 9-3 RHR PUMP C P-10-1C 10A-S2C 8)
CRP 9-3 RHR PUMP D P-10-10 10A-S2D 9)
CRP 9-3 CORE SPRAY PUMP A P-46-1A 14A-SSA 10)
CRP 9-3 CORE SPRAY PUMP B P-46-1B 14A-55B 11)
CRP 9-3 HPCI AUX OIL PUMP 23A-S17 12)
CRP 9-3 HPCI GL SL COND TANK PUMP 23A-S19 13)
CRP 9-3 HPCI GL SL VAC PUMP 23A-S10 14)
CRP 9-4 RECIRC LUBE GIL PUMP P-77-1A 2A-SSA 15)
CRP 9-4 RECIRC LUBE OIL PUMP P-77-1B 2A-S4A 16)
CRP 9-4 RECIRC LUBE OIL PUMP P-77-1C 2A-512A 17)
CRP 9-4 RECIRC LUBE OIL PUMP P-77-ID 2A-S3D 18)
CRP 9-4 RECIRC LUBE OIL PUMP P-77-1E 2A-S4B 19)
CRP 9-4 RECIRC LUPE OIL PUMP P-77-1F 2A-12B 20)
CRP 9-4 RECIRC GEN DRIVE MOTOR A CON f ROL 2A-SIA 21)
CRP 9-4 RECIRC GEN DRIVE MOTOR B CONTROL 2A-SID 22)
CRP 9-4 RWCU PUMP A P-49-1A 12A-S5 23)
CRP 9-4 RWCU PUMP B P-49-1B 12A-S6 24)
CRP 9-4 DRYWELL FLOOR DRAIN PUMP P-11-1A 20A-SIA 25)
CRP 9-4 DRYWELL EQUIP DRAIN PUMP P-15-1A 20A-SOA 26)
CRP 9-4 DECON SUMP PUMP P-37-1A 20A-S3A 27)
CRP 9-4 DRYWELL FLOOR DRAIN PUMP P-11-1B 20A-Sib 25)
CRP 9-4 DRYWELL EQUIP DRAIN PUMP P-15-1B 20A-S2P 26)
CRP 9-4 DECON SUMP PUMP P-37-1B 20A-53B 27)
CRP 9-4 RCIC GL SL 'fK COND PUMP 13A-S14 28)
CRP 9-4 RTIC GL SL VAC PUMP 13A-S15 29)
CRP 9-5 CRD PUMP A P-38-1A 3B-S4A 30)
CRP 9-5 CRD PUMP B P-38-1B 3R-S4D
- 31)
CRP 9-6 CONDENSAfE PUMP A SW-6 32)
CRP 9-6 CONDENSATE PUMP B SW-7 33)
CRP 9-6 CONDENSAfE PUMP C SW-8 34)
CRP 9-6 FEEDWATER PUMP A SW-9 35)
CRP 9-6 FEEDWATER PUMP B SW-10 36)
CRP 9-6 FEEDWATER PUMP C SW-11 37)
CRP 9-6 SERVICE WATER PUMP A SW-1 38)
CRP 9-6 SERVICE WATER PUMP B SW-2 39)
CRP 9-6 SERVICE WATER PUMP C SW-3 40)
CRP 9-6 SERVICE WATER PUMP D SW-4 41)
CRP 9-6 CIRC WATER PUMP A Su-32 42)
CRP 9-6 CIRC WATER PUMP B Su-33 43)
CRP 9-6 CIRC WATER PUMP C SW-11 44)
CRP 9-6 CIRC WATER B00STEk PUMP A SU.M 45)
CRP 9-6 CIRC WATER BOOSTER PUMP B SW-30 46)
CRP 9-6 CIRC WATER BOOSTER PUMP C SW-31 47)
CRP 9-6 DEMIN WATER TRANSFER PUMP A SW-46 48)
CRP 9-6 DEMIN WATER TRANSFER PUMP B SW-41 49)
CRP 9-6 COND VACUUM PUMP SW-16 50)
CRP 9-6 COND TRANSFER PUMP A SW-17 51)
CRP 9-6 COND TRANSFCR PUMP B SW-10 52)
CRP 9-6 HFATER DRAIN PUMP A SW-J3 53)
CRP 9-6 HEATER DRA IN PUMP B SW-24 54)
CRP 9-6 IB COOLING WTR PUMP A SW-12A 55)
CRP 9-6 TB COOLING WfR PUMP B SW-128 56)
CRP 9-6 RX BLDG CLG WTR PUMP A SW-19 57)
CRP 9-6 RX DLDG CLG WTR PUMP B SW-20 58)
CRP 9-7 STATOR COOLING PUMP SELECT SW-35 59)
CRP 9-7 AUX OIL PUMP SW-22 60)
CRP 9-7 LIFT PUMP MOTOR NO 1 SW-23 61)
CRP 9-7 LIFT PUMP MOTOR NO 2 SW-24 62)
CRP 9-7 LIFT PUMP MOTOR NO 3 SW-25 63)
CRP 9-23 EMERG BEARING OIL PUMP P-14-1A SW-2
64)
CRP 9-23 TURN GEAR OIL PUMP P-73-1A sy-3 1
65)
CRP 9-23 EMERG SEAL DIL PUMP P-51-1A sy-g 66)
CHP 9-23 MAIN SEAL OIL PUMP P-39-1A SW-20 67)
CRP 9-23 SEAL DIL VAC PUMP P-68-1A SW-21 ALL OTHER SWITCHES THAT ARE Ct!RRENTLY COLORED SHOULD PE BLACM (UNPAINTED) i e
J e
T i
i
+
,y m,,..,
,-.n 7
,,,. g n.n--.---n, a,,,,,.-,,
m,
.y-p.--g.-~.e,-
-,,-g--,,y_..g,,a.
._m.-
1 i
i 1
I i
I i
4 i
DE*ARCATION STANDAAD i
1 4
i l
l
ZONE CODING GUIDELINES
- 1. Vertical and horizontal linear analog recorder and indicator coding:
COLOR GREEN (Prestape no. T1712)
AM8ER (Prestape no. T1312)
RED (Prestape no. T1012)
DIMENSIONS Based on a viewing distance of 28 inches.
Minimum Width
.125" Minimum Length
.25" MATERIAL 1/8", pressure sensitive, transparent graphic tape.
Prestape by Prestype, Inc. recomended
- 2. Curvilinear analog indicator coding:
COLOR GREEN (Zipatone no. 2658)
AMBER (Zipatone no. 2734)
RED (Zipatone no. 2545)
DIMENSIONS Based on a viewing distance of 28 inches, color band is to follow the same arc as j
the gradations on the indicator being coded.
Minimum Width
.125" Minimum Length.25 " at center line of width MATERIAL Pressure sensitive, transparent, color film.
Cut film to match the desired width, length and arc of coding strip.
Zip-a-tone by Zipatone, Inc. recommended.
References:
Human Factors Design Handbook-Woodson McGraw-Hill,1981 NUREG 0700 MILSTD 1472 C OFC NAVAL RESEARCH AD 693237 i
VERMONT YANKEE l
IE D ' #'
ZONE CODING Implementation Guidelines 24 If Art 48HW D
- ATE A.S. RAmerte professional Consultants o
I
CUTLINES 1/18" Black (painted) with $5 degree. 3/8" corners.
UPS-18 Notes:
1.
Corners shall be no less than 1/8* from components os labels.
b 2.
Outilne shall M no less than 1/8" from 1
components or 10bels.
150 l
3.
Labels, for use with outilnes, shall be TYPE 9. unless otherwise specified.
4.
Mount TYPE 9 label 1/8" above topmost gega component in grouping, g4U 5.
Place outif ne 1/8" above TYPE 9 label.
i 1
l l
l l
j 8.am m8 81aco,ainted). with a.s de,ee 5,8 cha.fer.
. STEAM FLOW /
Notes:
1.
Chaefers must stay a minimue of 1/4' away from components or other demarcations.
T'-
L.....' T G N 2.
Labels, for use with brackets, shall be l
TYPE 9. unless otherwise spectff ed.
l I
3.
Horf rontally mount labels directly onts 150 150 center of bracket.
4 Labels are to be mounted 1/8" from top-most component in grouping, h
h 5.
Horizontal If ne of bracket should end parallel to the outermost component in grouping.
DIVISION LINES 1/18" Black (painted).
Notes:
- 1. Center division If ne between components to be separated.
2.
Extend if ne no less than 1/2' above topmost label or component, and below bottoo.aost component.
VERMONT YANKEE I;::;>- :.
ENHANCEMENT GUIDELINES Brackets, outlines, division line IA " ggM Z,//9,/st,
""U'""
2I i'
A.S. Asserts Profess #onalConsultants t
f
ATTACHMENT 3 H PC) 2-N-l 1
Proc. No. 0.P. 3140 Rev.
Hfti STl0 LN A.P Vil Dept. Supv.
Pl. Mgr._
PORC M00.
Issue Date Causes:
Setpoints:
Actuating Devices:
- 1. HPCI STEAL 1 BREAK.
IS0" W IDt DP\\S-23-W
References:
C.%)h \\4S4 Confirmation:
CHfbPMLOY CARO As.o_ a b F0l WT5 \\ ~1. lS.Y).10.
I Automatic Actions:
). M FC.!
\\ SOLAllOM.
1 Operator Actions:
3 700TTPV MCALTM &HEk.6 FOR RAD. A& SEED')E11T.
- 84. IOOTIFY M16WER MANA6E. MEA)T Ak/D Onllr TTcMiGAC5 4
ATTACHMENT 4 CONTROL OF OPERATOR AIDS AND TEMPORARY LABELS PURPOSE To initiate and maintain a syster to control placement and maintenance of operator aids and temporary labels on Operations Department control panels in the plant.
DISCUSSION Operator aids are:
sketches, notes, pictures, portions of plant procedures or plant drawings, tables and appendices from appropriate literature that are related to the process controlled by the panel on or near where they are posted.
They shall not be used in lieu of component labeling, in place of tagging pro-cedures or to bypass required review and approval mechanisms of information they represent.
Temporary labels are any labels affixed to the panels by operators via dymotape, or other suitable methods to improve operator understanding and effi-ciency, to label newly installed equipment, or to correct existing label infor-mation. Temporary labels may be used until permanent labels are available or until the temporary label is no longer necessary.
Temporary labels must be kept to a minimum and should be used only if necessary and only until a permanent label can be obtained.
REFERENCES A.
Tech Specs 1.
None B.
Admin Limits 1.
None C.
Other 1.
NUREG 0700, Guidelines for Control Room Design Reviews PREREQUISITES 1.
None PROCEDURES 1.
Control of Operator Aids A.
Authorization for Installation of Operator Aids 1.
Present the aid to a Shift Supervisor 2.
The Shift Supervisor will review it for the following:
e b.
Page 2 A.
Proposed location does not interfere with existing controls or identifications B.
Appropriate for intended use C.
Legibility D.
Validity 3.
The Shift Supervisor signifies his authorization by initialing and dating the aid.
4.
Present the aid to the Operations Department Supervisor for his concurring signature. When he initials the aid, he signifies his concurrence. The aid may then be posted as per Operator Aid Posting below.
B.
Operator Aid Posting 1.
Upon obtaining authorization, the originator writes a brief description and the reason for posting the aid in the Operator Aid / Temporary Label Status Book maintained in the Control Room.
2.
After the description, identify where it is to be posted, then initial and date the entry.
3.
Post the aid and notify the Shift Supervisor.
4.
The Shift Supervisor then observes the posting and initials the description in the Operator Aid / Temporary Label Status Book.
C.
Renoval of Operator Aids 1.
Present the proposal to the Shift Supervisor.
2.
If he concurs, the Shift Supervisor authorizes removal of the aid.
3.
Remove the aid.
4.
Draw a line through the written description of the aid in the Operator Aid / Temporary Label Status Book and notify the Shift Supervisor.
5.
The Shift Supervisor initials and dates the lined out descrip-tion.
2.
Control of Temporary Labels A.
Authorization for installation of temporary labels.
1.
Present the label to a Shift Supervisor.
2.
The Shift Supervisor will review it for the following:
'o Page 3 Proposed location does not interfere with existing controls a.
or identifications (unless the label is an old latal to be replaced).
b..
Appropriate for intended use.
c.
Legibility.
d.
Validity.
3.
The Shift Supervisor gives verbal authorization for the installa-tion.
B.
Application of Temporary Labels.
1.
Upon obtaining authorization, the originator writes a brief description and the reason for posting the temporary label in the Operator Aid / Temporary Label Status Book maintained in the Control Room.
2.
Post the temporary label. NOTE: Only dymotape labels should be used. Do not use markers, pens, or other similar devices.
C.
Removal of Temporary Labels 1.
Temporary labels may be removed with the verbal approval of a Shift Supervisor, or 2.
Temporary labels shall be removed as soon as a permanent label is available.
3.
When removing temporary labels, ensure that the entry in the Operator Aid / Temporary Label Status Book is removed by drawing a line through the entry, dating and initialing the change.
3.
Review of Operator Aids / Temporary Labels A.
Twice yearly the Shift Engineers review the Operator Aid / Temporary Label Status Book and the Operator Aids / Temporary Labels posted for the following:
1.
Postings are in agreement with their respective description in the status book, i
2.
Postings are in good repair.
3.
The information presented in the posting is valid.
4.
Postings do not interfere with existing controls or labels.
5.
Need for a permanent label or aid.
1
O o
Page 4 B.
During each review, the Shift Engineer consults with the Shift Supervisor or the Operations Department Supervisor to resolve any discrepancies for 3.A.5 above.
C.
At the end of the review and after all discrepancies are resolved, the Shift Engineer notes in the status book that he has performed the review and documents any resolution of discrepancies that are different from those described in ther status book.
4.
Operator Aid / Temporary Label Corrective Update A.
Follow the operator aid or temporary label removal and posting proce-dure to correct existing postings after obtaining permission to I
correct them from a Shift Supervisor.
FINAL CONDITIONS:
1.
Operator Aid / Temporary Label Status Book reflects the current status of all posted operator aids and temporary labels.
c f
_____o
ATTACHMENT 5 o
18 17 16 15 14 11 12 13 10 5
6 4
I 9
3 2
8 1
tocation Coding Key
=-
.o S
O ATTACHMENT 6 ADNINISTRATIVE PROCEDURE AP 0157 IDENTIFICATION OF INOPERATIVE INSTRUMENTATION AND CONTROL OF INDICATING LIGHTS PURPOSE:
To define the method used to identify inoperative instrumentation and the replacement of indicating light bulbs.
DISCUSSION:
When an instrument becomes suspect, it must be identified to preclude inad-vertent use'of the instrument by an operator, especially in the case of redun-dant control room instrumentation.
The sticker used for inoperative instrument is yellow with "Out of Commission", "Date", and " Initials" printed on it.
The use of this sticker on oortable instruments is explained in AP 0146, Control of Portable Calibration Test Instruments.
When indicating lights become suspect of being burned out, they must be changed out to ensure continued indication of plant conditions. During this changeout, controls are required to preclude the inadvertent interchanging of lens colors such that the meaning of each indicator remains unchanged.
REFERENCES:
A.
Tech Specs 1.
None B.
Admin Limits 1.
None C.
Other 1.
ANSI N18.7 Section 5.2.6 2.
AP 0025, Plant Equipment Control PROCEDURE:
1.
Control of Indicating Light Lens Colors A.
When Control Room component indicating lights are suspected of being burned out, the bulbs are to be checked / changed one at a time or concurrently with other indicating lights having the same color lenses. At no time shall indicating lens caps of different colors be removed simultaneously.
'9 e
o O
Page 2-2.
Control of Inoperative Instruments A.
When e Control Room instrument is'found to be questionable, defective, or out of calibration, notify the Shift Supervisor and attach a properly completed yellow "Out of Commission" sticker to the instrument.
B.
Insure other indication is not covered due to sticker placement.
C.
After the tag is attached, the person who discovered the problem submits a Maintenance Request.
D.
The Shift Supervisor shall note in the " Return to Service" space on the Maintenance Request the following:
1.
Upon satisfactory completion of repair (and retest if safety-related), the "Out of Commoission" sticker must be removed from the instrument and the equipment removed from the "IN-OP" section of VYAPF 0152.01 (Shift Turnover Checksheet).
E.
The Shift Supervisor then consults AP 0025, Plant Equipment Control, to determine if any additional action is necessary.
F.
The completed return to service section of the Maintenance Request controls and documents the removal of the Out-of-Commission stickers.