ML20137K729

From kanterella
Jump to navigation Jump to search
Partial Response to FOIA Request for Records Re Analysis, Review & Preparation of SER & EIS Fo OL Stage.Forwards App a Documents.Documents Also Made Available in PDR
ML20137K729
Person / Time
Site: Vogtle  
Issue date: 08/30/1985
From: Felton J
NRC OFFICE OF ADMINISTRATION (ADM)
To: Bell N
NUCLEAR INFORMATION & RESOURCE SERVICE
Shared Package
ML20136E513 List:
References
FOIA-84-663 NUDOCS 8509120249
Download: ML20137K729 (7)


Text

.

i l

e mp

[

o UNITED STATES

~,

8' NUCLEAR REGULATORY COMMISSION

{}

c E

W ASHING 10N. D. C. 20555

\\

s,

/

f)

+...+

AUG 30 585 Ms. Nina Bell Nuclear Information and Resource Service 1616 P Street, NW, Suite 160 IN RESPONSE REFER Washington, DC 20036 TO F01A-84-663

Dear Ms. Bell:

This is in partial response to your letter dated August 6,1985, in which you requested, pursuant to the Freedom of Information Act (FOIA), all records related to the analysis, review, and preparation of the Safety Evaluation Report and Environmental Impact Statement for the operating license stage for the Vogtle plant and all memoranda, correspondence and draft inputs.

The records identified on enclosed Appendix A are being made available for public inspection and copying at the NRC Public Document Room and will be filed in folder F01A-84-663 under your name.

The NRC has not completet its search for and review of the documents subject to your request. We will respond as soon as those actions are completed.

S

erely,

. Felton, Director Division of Rules and Records Office of Administration

Enclosures:

As stated hk'If@j9850830 BELLB4-g g

[

Re:

F0fA-84 663 APPENDIX A MEETINGS ATTENDED BY IE/QA 1.

06/26/84 Memo for E. G. Adensam from M. A. Miller -- FORTHCOMING MEETING ON STAFF QUESTIONS ON V0GTLE QUALITY ASSURANCE (M. A. Miller).

3 (4 pages) 2.

08/16/84 Memo for E. G. Adensam from M. A. Miller --

SUMMARY

OF MEETINGS ON V0GTLE, UNITS 1 AND 2 QUALITY ASSURANCE REVIEW (M. A. Miller).

(1page)

HEARING AND CONTENTION NOTES 3.

05/24/84 Memo for E. G. Adensam from M. A. Miller -- SITE VISIT TO V0GTLE TO DISCUSS QUALITY ASSURANCE BRANCH QUESTIONS (M. A. Miller).

(2 pages) 4.

05/29/84 Letter to C. Upright from J. Sprau -- FACSIMILE TRANSMISSION (J.Sprau).

(14 pages) 5.

09/19/84 Letter to L. Fowler and D. C. Teper from G. F. Trowbridge --

LICENSING BOARD (G. F. Trowbridge).

(2 pages) f e

6.

10/03/84 Attendance' List -- V0GTLE MEETING.

(1 page)

[

7.

10/04/84 Letter to J. Spraul from B. M. Bordenick -- NRC'S STAFF INTER 0GATORIES TO CAMPAIGN FOR A PROSPEROUS GEORGIA (CPG) AND GEORGIANS AGAINST NUCLEAR ENERGY (B. M. Bordenick).

(6 pages) 8.

11/20/84 Letter to B. M. Bordenick from J. Spraul -- V0GTLE

}

INTERR0GATIVES (J. Spraul).

(1 page) 9.

12/19/84 Letter to B. M. Bordenick fron D. Teper -- CPG /GANE (D. Teper).

(1page) 10.

12/31/84 Letter to J. Spraul from Shelane -- STAFF INTERROGATIVES (Shelane).

(11pages)

CORRESPONDENCE

11. 08/08/83 Mero from E. G. Adensam from W. P. Haass -- ACCEPTANCE REVIEW, V0GTLE FSAP, QA BRANCH (W. P. Haass).

(6 pages)

IN. 09/06/83 Letter to D. Foster from D. G. Eisenhut -- ACCEPTANCE REVIEW 0F APPLICATION FOR OL LICENSE FOR V0GTLE ELECTRIC GENERATING STATION, UNITS 1 AND 2 (D. G. Eisenhut).

(3 pages)

4 Re:

F0!A-84-663 APPENDIX A (CONTINUED)

CORRESPONDNECE (CONTINUED) 13.

11/11/83 Letter to H. R. Denton from D. O. Foster -- NRC DOCKET NUMBERS 50-424 AND 50-425 CONSTRUCTION PERMIT NUMBERS CPPR-108 AND CPPR-109 V0GTLE ELECTRIC GENERATING PLANT - UNITS 1 AND 2 APPLICATION FOR OPERATING LICENSES FSAR AMENDMENT NUMBER 1 (D. O. Foster).

(3 pages) 14.

12/04/84 Letter to D. G. Eisenhut from D. O. Foster -- NRC DOCKET NUMBERS (D. O. Foster).

(4 pages)

15. 01/30/85 Memo for Persons on Attached List from E. G. Adensam --

V0GTLE - RESPONSE TO DES COMMENTS FOR INCLUSION IN FES (E. G. Adensam).

(5pages)

16. 02/25/85 Memo for T. M. Novak from B. K. Grimes -- V0GTLE:

RESPONSE

TO DES COMMENTS (B. K. Grimes).

(3 pages)

SER INPUT INFORMATION i

17. 09/25/84 Memo for T. M. Novak from J. N. Grace -- QA BRANCH INPUT FOR V0GTLE SER (J. N. Grace).

(1 page)

18. 09/25/84 Memo for T. M. Novak from J. N. Grace -- QA BRANCH INPUT FOR V0GTLESER(J.N. Grace.

(12 pages) 19.

11/06/84 Letter to D. O. Foster from T. M. Novak -- DRAFT SER FOR V0GTLE UNITS 1 AND 2 (T. M. Novak).

(3 pages) 20, 12/12/84 Memo for Those listed on page from T. M. Novak -- SER INPUT FOR V0GTLE, UNITS 1 AND 2 (T. M. Novak).

(2 pages)

21. 03/20/85 Memo for Those listed on page from T. M. Novak -- SER INPUT FOR V0GTLE, UNITS 1 AND 2 (T. M. Novak).

(12pages)

22. 04/03/85. Memo for T. M. Novak from B. K. Grimes -- SER INPUT FOR V0GTLE UNITS 1 AND 2 (T. M. Novak).

(6 pages)

ANSWERS / RESPONSES TO QA CONCERNS l

23, 3/0/84 Amendment 15 -- Beginning with question 252.1 5/31/84 and ending with questions 260.39 4/30/84 l

l 1

j Re:

F01A 84-663 APPENDIX A (CONTINUED)

ANSWERS / RESPONSES TO QA CONCERNS (CONTINUED)

24. 3/0/85 Amendment 15 -- Beginning with questions 260.40 04/30/84 cad ending with question 281.1 1/23/84
25. 7/0/84 Amendment 8 -- Question 260.1 and the Response 26, 7/0/84 Amendment 8 -- Question 260.2 and the Response
27. 7/0/84 Amendment 8 -- Question 260.3 and the Response
28. 7/0/84 Amendment 8 -- Question 260.4 and the Response
29. 7/0/84 Amendment 8 -- Question 260.5 and the Response
30. 7/0/84 Amendment 8 -- Question 260.6 and the Response
31. 7/0/84 Amendment 8 -- Question 260.7 and the Response
32. 7/0/84 Amendment 8 and Amendment 9 -- Question 260.8 and the Response
33. 7/0/84 Amendment 8 -- Question 260.9 and the Response
34. 7/0/84 Amendment 8 -- Question 260,10 and the Response
35. 7/0/84 Amendment 8 -- Question 260,11 and the Response
36. 7/0/84 Amendment 8 -- Question 260.12 and the Response
37. 7/0/84 Amendment 8 -- Question 260,13 and the Response
38. 7/0/84 Amendment 8 -- Question 260.14 and the Response 39, 7/0/84 Amendment 8 -- Question 260.15 and the Response
40. 7/0/84 Amendment 8 -- Question 260.16 and the Response 41, 7/0/84 Amendment 8 -- Question 260.17 and the Response.

(2 pages)

42. 7/0/84 Amendment 8 -- Question 260.18 and the Response
43. 7/0/84 Amendment 8 -- Question 260.19 and the Response l
44. 7/0/84 Amendment 8 -- Question 260.20 and the Response.
45. 7/0/84 Amendment 8 -- Question 260.21 and the Response.

46, 7/0/84 Amendment 8 -- Question 260.21 and the Response.

(2pages)

T Re:

F01A 84-663 APPENDIX A (CONTINUED)

ANSWERS / RESPONSES TO QA CONCERNS CONTINUED

47. 7/0/84 Amendment 8 -- Question 260.23 and the Response
48. 7/0/84 Amendment 8 -- Question 260.24 and the Response
49. 7/0/84 Amendment 8 -- Question 260.25 and the Response
50. 7/0/84 Amendment 8 -- Question 260.26 and the Response
51. 7/0/84 Amendment 8 -- Question 260.27 and the Response 52, 7/0/84 Amendment 8 -- Question 260.28 and the Response
53. 7/0/84 Amendment 8 -- Question 260.29 and the Response
54. 7/0/84 Amendment 8 -- Question 260.30 and the Responst
55. 7/0/84 Amendment 8 -, Question 260.31 and the Response
50. 7/0/84 Amendment 8 -- Question 260.32 and the Response
57. 7/0/84 Amendment 8 -- Question 260.33 and the Response 58, 7/0/84 Amendment 8 -- Question 260.34 and the Response
59. 7/0/84 Amendment 8 -- Question 260.35 and the Response
60. 7/0/84 Amendment 8 -- Question 260.36 and the Response
61. 7/0/84 Amendment 8 -- Question 260.37 and the Response
62. 7/0/84 Amendment 8 -- Question 260.38 and the Response
63. 7/0/84 Amendment 8 -- Question 260.39 and the Response
64. 7/0/84 Amendment 8 -- Question 260.40 and the Response
65. 7/0/84 Amendment 8 -- Question 260.41 and the Response
66. 7/0/84 Amendment 8 -- Question 260.42 and the Response
67. 7/0/84 Amendment 8 -- Question 260.43 and the Response
68. 7/0/84 Amendment 8 -- Question 260.44 and the Response 69, 7/0/84 Amendment 8 -- Question 260.45 and the Response

Re:

F01A M-663 i

APPENDIX A (CONTINUED)

ANSWERS / RESPONSES TO QA CONCERNS (CONTINUED) 70.

7/0/84 Amendment 8 -- Question 260.46 and the Response

71. 7/0/84 Amendment 8 -- Question 260.47 and the Response
72. 7/0/84 Amendment 8 -- Question 260.48 and the Response
73. 7/0/84 Amendment 8 -- Question 260.49 and the Response 74 7/0/84 Amendment 8 -- Question 260.50 anif the Response
75. 7/0/84 Amendment 8 -- Question 260.51 and the Response
76. 7/0/84 Amendment 8 -- Question 260.52 and the Respense
77. 7/0/84 Amendment 8 -- Question 260.53 and the Response
78. 7/0/84 Amendment 8 -- Question 260.54 and the Response
79. 7/0/84 Amendment 8 -- Question 260.55 and the Response
80. 7/0/84 Amendment 8 -- Question 260.56 and the Response
81. 7/0/84 Amendment 8 -- Question 260.57 and the Response
82. 7/0/84 Amendment 8 -- Question 260.58 and the Response 83.

7/0/84 Amendment 8 -- Question 260.59 and the Response

84. 7/0/84 Amendment 8 -- Question 260.60 and the Response 85.

12/11/83 Note to J. L. Milhoan from M. Malloy -- PRELIMINARY REVIEW 0F V0GTLE ELECTRIC GENERATING PLANT UNITS 1 AND 2 (M. Malloy).

(5 pages) 86.

12/11/83 Letter to Jim # rom M. Malloy -- V0GTLE REVIEW (M. Malloy).

(1 page)

87. 04/08/84 Note to J. Spaul from M. Malloy -- RESULTS OF V0GTLE QQAP REVIEW (M.Malloy).

(37 pages)

88. 04/12/84 Memo from T. M. Novak from J. N. Grace -- REQUEST FOR ADDITIONAL INFORMATION: V0GTLE QUALITY ASSURANCE (J. N. Grace).

(17 pages) l

89. 04/30/84 Letter to D. O. Foster from E. G. Adensam -- REQUEST FOR ADDITIONAL INFORMATION ON V0GTLE, UNITS 1 AND 2 (E. G. Adendam).

(15 pages) l

f Re: F01A-84-663 APPENDIX A (CONTINUED)

CHECKLIST

90. 8/0/83 Review Check' list -- V0GTLE ELECTRIC GENERATING STATION.

(15 pages)

SECOND REVIEW NOTES MELINDA MALLOY

91. 04/08/84 Note to J. Spraul from M. Malloy -- RESULTS OF V0GTLE QQAP REVIEW (M.Malloy).

(est. 150 pages)

92. 06/12/84 Letter from M. Malloy -- V0GTLE QA MEETING (M. Malloy).

(7 pages)

REVIEW INFORMATION ON PREPARATION OF CURRENT SSER (4/85)

93. 12/27/84 Memo for T. M. Novak from B. K. Grimes -- QA BRANCH SER UPDATE FOR V0GTLE (B. K. Grimes).

(16 pages)

94. Undated Letter -- V0GTLE QA OPEN ITEMS.

(3 pages)

95. 03/18/85 Letter to J. Spraul from M. Malloy -- V0GTLE QA OPEN ITEMS (M.Malloy).

(17 pages)

96. 03/27/85 Letter to Those listed on page from J. Spraul -- QAB INPUT TO V0GTLE SER (J. Spraul).

(2 pages) i

  • y

!