Forwards Sanitized Safeguards Insp Rept 70-1113/84-02 on 840206-10.No Violations or Deviations Identified
ML20137D801
Person / Time
Site: 07001113
Issue date: 03/02/1984
From: Stohr J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Long J
GENERAL ELECTRIC CO.
Shared Package
ML20137D194 List:
References
FOIA-85-554 NUDOCS 8511270148
Download: ML20137D801 (1)


Text

.~,~.e..c, w.....-.

y ., _. ,kf' ~;.

,.- ,[p

~

'o uNetE2 STATES .

JCLEAR CECULAT!CY COMMISSION -?, ; .-

,' 'O '  % C E CION Il -

=

-)

$ 101 M "/~.IE TT A STIE E T. O.W.

t AYt AM f A. OE0011GIA 30303 m

\, ...../ .

MAR 0 2 W

^

c General Electric Company ATTN: Mr. J. A. Long, General Manager Wilmington Manufacturing Department '

P. O. Box 780 Wilmington, NC 28402 Gentlemen:

SUBJECT:

REPORT NO. 70-1113/84-02 On February 6-10, 1984, NRC inspected activities authorized by NRC License No. $NM-1097 for your Wilmington Manufacturing Department facility. At the conclusion of the inspection, the findings were discussed with those enembers of your staff identified in the enclosed inspection report.

Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observation of activities in progress.

Within the scope of the inspection, no violations or deviations were identified.

In accordance with 10 CFR 2.790(d) and 10 CFR 73.21, safegua'rds activities and security measures are exempt from public disclosure; therefore, the enclosures to this letter, with the exception of the report cover page which presents a nonexempt summary, will not be placed in NRC's Public Document Room.

Should you have any questions concerning this letter, please contact us.

Sincerely, f-~ >

, ,I

'? ( \ s

. hilig tohr , Director Division of Emergency Preparedness and Materials Safety Programs

Enclosure:

Inspection Report No. 70-1113/84-02 (Exempt from Disclosure) cc w/ enc 1:

C. M. Vaughan, Manager Licensing and Nuclear Materials Management Unit 8511270148 851119 VDN FotA RATNEN85-554 PDR

.N

. m ,- .