| | | Reporting criterion |
|---|
| 05000354/LER-1996-001-03, :on 960113,safety & Turbine Acs HXs Fouled W/Grass Due to Failed Service Water Strainer.Caused by Detritus Overloading.Strainer Replaced & Maint & Design Mods Enhanced |
- on 960113,safety & Turbine Acs HXs Fouled W/Grass Due to Failed Service Water Strainer.Caused by Detritus Overloading.Strainer Replaced & Maint & Design Mods Enhanced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |
| 05000354/LER-1996-001, :on 960113,safety & Turbine Acs Heat Exchangers Fouled W/Detritus Occurred Due to Failed Svc Water Strainer. Strainers Replaced & Enhanced Maint & Design Mod |
- on 960113,safety & Turbine Acs Heat Exchangers Fouled W/Detritus Occurred Due to Failed Svc Water Strainer. Strainers Replaced & Enhanced Maint & Design Mod
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(e)(2)(x) 10 CFR 50.73(s)(2)(iv) |
| 05000354/LER-1996-002-01, :on 960119,TS Violation Occurred Re Failure to Complete Flood Protection Actions within Required Timeframe. Caused by Malfuntioned three-way Pneumatic Supply Valve. Repaired Watertight Door |
- on 960119,TS Violation Occurred Re Failure to Complete Flood Protection Actions within Required Timeframe. Caused by Malfuntioned three-way Pneumatic Supply Valve. Repaired Watertight Door
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000354/LER-1996-003, :on 960214,failure to Perform Rcics Surveillances Condition Prohibited by Ts.Caused by Inadequate Review & Testing of Procedures.Surveillance Procedure Revised & Testing of Subject Valves |
- on 960214,failure to Perform Rcics Surveillances Condition Prohibited by Ts.Caused by Inadequate Review & Testing of Procedures.Surveillance Procedure Revised & Testing of Subject Valves
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000354/LER-1996-004, :on 960229,discovered Required IST Surveillances for D Safety Auxiliaries Cooling Sys Pump & B Station Svc Water Pump Not Performed.Caused by Less than Adequate Oversight.Instruction Provided |
- on 960229,discovered Required IST Surveillances for D Safety Auxiliaries Cooling Sys Pump & B Station Svc Water Pump Not Performed.Caused by Less than Adequate Oversight.Instruction Provided
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-005, :on 960130,inadequate Surveillance Testing for RHR Suppression Pool & Spray Modes Occurred.Caused by Lack of Rigorous Application of Engineering Priciples.Ts Surveillance Requirements Revised |
- on 960130,inadequate Surveillance Testing for RHR Suppression Pool & Spray Modes Occurred.Caused by Lack of Rigorous Application of Engineering Priciples.Ts Surveillance Requirements Revised
| 10 CFR 50.73(a)(2)(i) |
| 05000354/LER-1996-006, :on 920120,side Backdraft Isolation Dampers Installed Backwards.Caused by Construction Error.Restored Backdraft Isolation Dampers to Design Configuration |
- on 920120,side Backdraft Isolation Dampers Installed Backwards.Caused by Construction Error.Restored Backdraft Isolation Dampers to Design Configuration
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-008, :on 920510,plant Operated W/Control Rod Withdrawal Speeds Outside of Design Basis.Caused by mis-adjustment of Control Rod Drive Sys Flow Control Needle Valves.Rods Properly Set within UFSAR Limits |
- on 920510,plant Operated W/Control Rod Withdrawal Speeds Outside of Design Basis.Caused by mis-adjustment of Control Rod Drive Sys Flow Control Needle Valves.Rods Properly Set within UFSAR Limits
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |
| 05000354/LER-1996-009, :on 960317,determined That Plant Operating in Unanalyzed Condition Due to Inappropriate Sws/Safety Auxiliary Cooling Sys Throttle Valve Settings.Repositioned Valves & Revised Appropriate Procedures |
- on 960317,determined That Plant Operating in Unanalyzed Condition Due to Inappropriate Sws/Safety Auxiliary Cooling Sys Throttle Valve Settings.Repositioned Valves & Revised Appropriate Procedures
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-010, :on 960319,automatic Isolation Signal Received from High Steam Flow Signal.Caused by Deficient RCIC warm-up Procedure.Isolation Signal re-set,warm-up Completed & RCIC Sys Returned to svc.Warm-up Procedure Revised |
- on 960319,automatic Isolation Signal Received from High Steam Flow Signal.Caused by Deficient RCIC warm-up Procedure.Isolation Signal re-set,warm-up Completed & RCIC Sys Returned to svc.Warm-up Procedure Revised
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-011, :on 960320,HPCIS Failed Surveillance & ADS Declared Inoperable Resulting in Entry Into TS 3.0.3.Caused by Personnel Error.Procedures Revised & Personnel Trained |
- on 960320,HPCIS Failed Surveillance & ADS Declared Inoperable Resulting in Entry Into TS 3.0.3.Caused by Personnel Error.Procedures Revised & Personnel Trained
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-012, :on 960320,missed Offgas Sample Resulting in Condition Prohibited by Ts.Caused by Defective Needle Luer Lock Adapter.Needle Luer Lock Adapter on Backup Sample Apparatus Replaced |
- on 960320,missed Offgas Sample Resulting in Condition Prohibited by Ts.Caused by Defective Needle Luer Lock Adapter.Needle Luer Lock Adapter on Backup Sample Apparatus Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000354/LER-1996-013, :on 960406,ESFA Occurred Due to Isolation of MSL Drain Inboard Isolation Valve.Replaced & Tested Circuit Board |
- on 960406,ESFA Occurred Due to Isolation of MSL Drain Inboard Isolation Valve.Replaced & Tested Circuit Board
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |
| 05000354/LER-1996-014, :on 960416,nonconservative Safety Limit Min Critical Power Ratio Calculation Methodology Error Discovered.Caused by Inadequate Design Assumptions.Interim Controls Placed on MCPR |
- on 960416,nonconservative Safety Limit Min Critical Power Ratio Calculation Methodology Error Discovered.Caused by Inadequate Design Assumptions.Interim Controls Placed on MCPR
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-015, :on 960410,potential to Operate in Unanalyzed Condition Occurred.Caused by Original Design Calculation Deficiency.Appropriate Maximum UHS Temp Will Be re-evaluated |
- on 960410,potential to Operate in Unanalyzed Condition Occurred.Caused by Original Design Calculation Deficiency.Appropriate Maximum UHS Temp Will Be re-evaluated
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition |
| 05000354/LER-1996-016, :on 960427,unplanned High Pressure Coolant Injection Sys Inoperability Due to Blown Fuse & Trip Unit Card Failure.Caused by Shorted Capacitor.Trip Unit Card & Fuse Were Replaced |
- on 960427,unplanned High Pressure Coolant Injection Sys Inoperability Due to Blown Fuse & Trip Unit Card Failure.Caused by Shorted Capacitor.Trip Unit Card & Fuse Were Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |
| 05000354/LER-1996-017, :on 960505,failed to Perform Electrical Distribution Sys line-up.Caused by Personnel Error.Personnel Issues Addressed & Repaired Temp Control Valves for a and D Emergency Diesel Generator |
- on 960505,failed to Perform Electrical Distribution Sys line-up.Caused by Personnel Error.Personnel Issues Addressed & Repaired Temp Control Valves for a and D Emergency Diesel Generator
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000354/LER-1996-018, :on 960522,failed to Test Control Room Emergency Filtration Sys.Caused by Inadequate Review & Approval of Surveillance Activities.Revised Surveillance Procedures |
- on 960522,failed to Test Control Room Emergency Filtration Sys.Caused by Inadequate Review & Approval of Surveillance Activities.Revised Surveillance Procedures
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-019, :on 960614,LPCI Has Not Been Appropriately Tested as Specified in TS SR 4.5.1.c.1.Caused by Ineffective Reviews of Procedures That Implement TS Requirements. Procedures Implementing TS Sr,Will Be Reviewed |
- on 960614,LPCI Has Not Been Appropriately Tested as Specified in TS SR 4.5.1.c.1.Caused by Ineffective Reviews of Procedures That Implement TS Requirements. Procedures Implementing TS Sr,Will Be Reviewed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-020, :on 960719,south Plant Vent Radioactive Gaseous Effluent Monitor Declared Inoperable.Caused by Failure to Perform Actions for Inoperable Instrumentation.Frequency of Grab Samples Flow Estimations Increased |
- on 960719,south Plant Vent Radioactive Gaseous Effluent Monitor Declared Inoperable.Caused by Failure to Perform Actions for Inoperable Instrumentation.Frequency of Grab Samples Flow Estimations Increased
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-021-01, :on 961020,operation in Condition Prohibited by TS Due to Failure to Adequately Perform Standby Liquid Control Sys Surveillances.Temporary Log Was Established to Record Actual Tank Temperature |
- on 961020,operation in Condition Prohibited by TS Due to Failure to Adequately Perform Standby Liquid Control Sys Surveillances.Temporary Log Was Established to Record Actual Tank Temperature
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-022-02, Forwards LER 96-022-02,documenting Event That Occurred at Hope Creek Generating Station,Unit 1.Util Commitments Made within Ltr,Listed | Forwards LER 96-022-02,documenting Event That Occurred at Hope Creek Generating Station,Unit 1.Util Commitments Made within Ltr,Listed | 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition |
| 05000354/LER-1996-022, :on 960816,identified Condition That Could Have Prevented Removal of RHR safety-auxiliaries Cooling Sys for Deficiencies.Caused by Procedure Changes Made W/O Adequate Review.Established Administrative Controls |
- on 960816,identified Condition That Could Have Prevented Removal of RHR safety-auxiliaries Cooling Sys for Deficiencies.Caused by Procedure Changes Made W/O Adequate Review.Established Administrative Controls
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |
| 05000354/LER-1996-023, :on 960821,RCIC Sys Isolation Occurred Due to Failed Steam Leak Detection Monitor.Failure Drawer Was Replaced & RCIC Sys Was Returned |
- on 960821,RCIC Sys Isolation Occurred Due to Failed Steam Leak Detection Monitor.Failure Drawer Was Replaced & RCIC Sys Was Returned
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000354/LER-1996-024-01, :on 961029,two Redundant Vacuum Breakers on a Station Svc Water Sys Loop Were Tested & Found Inoperable Due to Accumulation of Deposits on Internal Moving Parts. Both Vacuum Breakers on a Station,Repaired |
- on 961029,two Redundant Vacuum Breakers on a Station Svc Water Sys Loop Were Tested & Found Inoperable Due to Accumulation of Deposits on Internal Moving Parts. Both Vacuum Breakers on a Station,Repaired
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-025-01, :on 961107,during warm-up of RCIC Sys Automatic Isolation Signal Received from High Steam Flow Signal.Caused by Spurious Steam Line Pressure &/Or Steam Line Flow Signals.Rcic Isolation Signal Reset & Work Order Initiated |
- on 961107,during warm-up of RCIC Sys Automatic Isolation Signal Received from High Steam Flow Signal.Caused by Spurious Steam Line Pressure &/Or Steam Line Flow Signals.Rcic Isolation Signal Reset & Work Order Initiated
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-025, Forwards LER 96-025-00.Commitments Listed Including Work Order Initiated to Install Recording Instrumentation to Determine Actual Line Dynamics During Next RCIC warm-up | Forwards LER 96-025-00.Commitments Listed Including Work Order Initiated to Install Recording Instrumentation to Determine Actual Line Dynamics During Next RCIC warm-up | 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000354/LER-1996-026-01, :on 961108,ESF Actuation/Single Rod Scram Occurred Due to Stuck Scram Solenoid Pilot.Sspv Replaced & CR 42-07 Returned to Svc |
- on 961108,ESF Actuation/Single Rod Scram Occurred Due to Stuck Scram Solenoid Pilot.Sspv Replaced & CR 42-07 Returned to Svc
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-027-01, :on 961202,ESF Actuation & Unplanned Automatic Start of Safety Auxiliaries Cooling Sys Pump a Occurred Due to Personnel Error.Nco Involved in Event Counseled |
- on 961202,ESF Actuation & Unplanned Automatic Start of Safety Auxiliaries Cooling Sys Pump a Occurred Due to Personnel Error.Nco Involved in Event Counseled
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-028-01, :on 961220,potential Loss of Containment Integrity Occurred Due to Water Hammer in Drywell Cooler Piping.Administrative Controls Were Implemented to Prevent Defeating of Drywell Cooler Isolation Interlocks |
- on 961220,potential Loss of Containment Integrity Occurred Due to Water Hammer in Drywell Cooler Piping.Administrative Controls Were Implemented to Prevent Defeating of Drywell Cooler Isolation Interlocks
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-028, Forwards LER 96-028-00,submitted Pursuant to Requirements of 10CFR50.73(a)(2)(v).Commitments Listed | Forwards LER 96-028-00,submitted Pursuant to Requirements of 10CFR50.73(a)(2)(v).Commitments Listed | 10 CFR 50.73(a)(2)(v), Loss of Safety Function |
| 05000354/LER-1996-029-01, :on 961228,unplanned Reactor Core Isolation Cooling Sys Inoperability Occurred Due to Stuck Governor Valve.Valve Stem Was Replaced & RCIC Sys Was Returned to Service on 961230 |
- on 961228,unplanned Reactor Core Isolation Cooling Sys Inoperability Occurred Due to Stuck Governor Valve.Valve Stem Was Replaced & RCIC Sys Was Returned to Service on 961230
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function |
| 05000354/LER-1996-030-01, :on 961230,uplanned HPCI Sys Inoperability Occurred Due to Stuck Open Extended Containment Boundary Valve.Repaired Check Valve & HPCI Sys Restored |
- on 961230,uplanned HPCI Sys Inoperability Occurred Due to Stuck Open Extended Containment Boundary Valve.Repaired Check Valve & HPCI Sys Restored
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) |
| 05000354/LER-1996-030, Submits List of Commitments Re Unplanned HPCI Sys Inoperability Due to Stuck Open Extended Containment Boundary Valve in LER 96-030-00 | Submits List of Commitments Re Unplanned HPCI Sys Inoperability Due to Stuck Open Extended Containment Boundary Valve in LER 96-030-00 | 10 CFR 50.73(a)(2)(v), Loss of Safety Function |
| 05000354/LER-1996-033, :on 951114,two Events Occurred Due to Identification of TS Surveillance Test Inadequacy.Caused by Ineffective Procedures.Tssip Review Will Be Completed |
- on 951114,two Events Occurred Due to Identification of TS Surveillance Test Inadequacy.Caused by Ineffective Procedures.Tssip Review Will Be Completed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) |