Notice of Consideration of Issuance of Amends to Licenses NPF-9 & NPF-17 & Opportunity for Prior Hearing.Amends Change Tech Specs to Allow Operation W/Reduction in Total Min Weight of Ice in Containment Ice Condenser Sys
ML20133H729
Person / Time
Site: McGuire, Mcguire  
Issue date: 07/31/1985
From: Hood D
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20133H716 List:
References
TAC-57335, TAC-57336, NUDOCS 8508090478
Download: ML20133H729 (4)


Text

7590-01 4

UNITED STATES NUCLEAR REGULATORY COMMISSION DUKE POWER COMPANY DOCKET NOS. 50-369 AND 50-370 NOTICE OF CONSIDERATION OF ISSUANCE OF AMENDMENTS TO FACILITY OPERATING LICENSES AND OPPORTUNITY FOR PRIOR HEARING The United States Nuclear Regulatory Comission (the Commission) is con-sidering issuance of amendments to Facility Operating License No. NPF-9 and Facility Operating License No. NPF-17, issued to Duke Power Ccmpany (the licensee),

for operation of the McGuire Nuclear Station, Units 1 and 2, located in Mecklenburg County, North Carolina.

The proposed amendments would change Technical Specification 3.6.5.1 for McGuire Units 1 and 2 to allow operation with a total minimum weight of ice in the containment Ice Condenser System reduced from 2,466,420 to 2,355,320 pounds.

By letter dated April 5, 1985, the licensee requested the proposed change and provided the results of a reanalysis of the design basis containment pressure calculation provided in FSAR Section 6.2.1.

The new analysis was performed by Westinghouse using a reduced ice bed weight and an earlier diversion of partial Residual Heat Removal System flow to the containment spray pumps (from 3590 to 3000 seconds after the LOCA), and resulted in a slightly earlier and reduced containment peak pressure.

(Earlier RHR spray actuation during a LOCA is imple-mented by the licensee through changes to plant operating procedures rather than Technical Specifications.) On the basis of the revised Westinghouse calcula-tions, the licensee concludes that implementation of the proposed changes would provide for the control of a containment pressure transient in a shorter time without reduction of existing safety margins.

850B090478 850731 PDR ADOCK 05000369 P

PDR l

L

. Prior to issuance of the proposed license amendments, the Comission will have made findings required by the Atomic Energy Act of 1954, as amended. (the Act) and the Commission's regulations.

By September 4,1985, the licensee may file a request for a hearing with respect to issuance of the amendments to the subject facility operating licenses and any person whose interest may be affected by this proceeding and who wishes to participate as a party in the proceeding must file a written petition for leave to intervene. Requests for a hearing and petitions for leave to intervene shall be filed in accordance with the Comission's " Rules of Practice for Domestic Licensing Proceedings" in 10 CFR Part 2.

If a request for a hearing or petition for leave to intervene is filed by the above date, the Commission or an Atomic Safety and Licensing Board, designated by the Comission or by the Chainnan of the Atomic Safety and Licensing Board Panel, will rule on the request and/or petition and the Secretary or the designated Atomic Safety and Licensing Board will issue a notice of hearing or an appropriate order.

As required by 10 CFR 62.714, a petition for leave to intervene shall set forth with particularity the interest of the petitioner in the proceeding, and how that interest may be affected by the results of the proceeding. The petition should specifically explain the reasons why intervention should be permitted with particular reference to the following factors:

(1) the nature of the petitioner's right under the Act to be made a party to the proceeding; (2) the nature and extent of the petitioner's property, financial, or other interest in the pro-ceeding; and (3) the possible effect of any order which may be entered in the proceeding on the petitioner's interest. The petition should also Identify the specific aspect (s) of the subject matter of the proceeding as to which petitioner

5

. wishes to intervene. Any person who has filed a petition for leave to intervene or who has been admitted as a party may amend the petition without requesting leave of the Board up to fifteen (15) days prior to the first prehearing con-ference scheduled in the proceeding, but such an amended petition must satisfy the specificity requirements described above.

Not later than fifteen (15) days prior to the first prehearing conference scheduled in the proceeding, a petitioner shall file a supplement to the petition to intervene which must include a list of the contentions which are sought to be

~

litigated in the matter, and the bases for each contention set forth with reason-able specificity.

Contentions shall be limited to matters within the scope of the amendments under consideration. A petitioner who fails to file such a supplement which satisfies these requirements with respect to at least one contention will not be permitted to participate as a party.

Those permitted to intervene become parties to the proceeding, subject to any limitations in the order granting leave to intervene, and have the oppor-tunity to participate fully in the conduct of the hearing, including the opportunity to present evidence and cross-examine witnesses.

A request for a hearing or a petition for leave to intervene shall be filed with the Secretary of the Comission, United States Nuclear Regulatory Commission, Washington, D. C.

20555, Attention: Docketing and Service Branch, or may be delivered to the Comission's Public Document Room,1717 H Street, N.W.,

Washington, D. C. by the above date. Where petitions are filed during the last ten (10) days of the notice period, it is requested that the petitioner or representative for the petitioner promptly so inform the Commission by a toll-l L

4-free telephone call to Western Union at (800) 325-6000 (in Missouri (800) 342-6700). The Western Union operator should be given Datagram Identification Number 3737 and the following message addressed to Elinor G. Adensam: petitioner's name and telephone number; date petition was mailed; plant name; and publication date and page number of this FEDERAL REGISTER notice. A copy of the petition should also be sent to the Executive legal Director, U. S. Nuclear Regulatory Comission, Washington, D. C. 20555, and to Mr. Albert Carr, Duke Power Company, P.O. Box 33189, 422 South Church Street, Charlotte, North Carolina 28242, attorney for the licensee.

Nontimely filings of petitions for leave to intervene, amended petitions supplemental petitions and/or requests for hearing will not be entertained absent a determination by the Commission, the presiding officer or the Atomic Safety and licensing Board designated to rule on the petition and/or request, that the petitioner has made a substantial showing of good cause for the granting of a late petition and/or request. That determination will be based upon a balancing of the factors specified in 10 CFR 2.714(a)(1)(1)-(v) and 2.714(d).

For further details with respect to this action, see the application for amendments dated April 5,1985, which is available for public inspection at the Comission's Public Document Room,1717 H Street, N.W., Washington, D. C. and at the Atkins library, University of North Carolina, Charlotte (UNCC Station), North Carolina 28242.

st Dated at Bethesda, Maryland this 31 day of July 1985.

FOR THE NUCLEAR REGULATORY COMMISSION MA Darl S. Hood, Acting Chief licensing Branch No. 4 Division of licensing